ML112312316

From kanterella
Jump to navigation Jump to search
Request for Additional Information Regarding Temporary Non-Code Compliant Condition
ML112312316
Person / Time
Site: Millstone Dominion icon.png
Issue date: 08/19/2011
From: Sanders C
Plant Licensing Branch 1
To: Bartron W, Brown W
Dominion Nuclear Connecticut
Sandeers, Carleen, NRR/DORL, 415-1603
Shared Package
ML112312317 List:
References
Download: ML112312316 (1)


Text

From:

Sanders, Carleen Sent:

Friday, August 19, 2011 10:57 PM To:

'william.d.bartron@dom.com'; 'william.e.brown@dom.com'

Subject:

Millstone 2: Request for Additional Information Regarding Temporary Non-Code Compliant Condition Attachments:

Millstone 2 flange RAIs.docx Mr. William Bartron, By letter dated August 19, 2011, Dominion Nuclear Connecticut, Inc. (DNC or the licensee) requested relief from certain Section XI requirements of the American Society of Mechanical Engineers (ASME)

Boiler and Pressure Vessel Code (ASME Code) for Millstone Power Station, Unit No. 2 (MPS2). Relief Request RR-04-12 is based on the hardship of performing required ASME Code repair/replacement activities to a degraded piping flange in the A train 10-inch service water (SW) supply line to the emergency diesel generator heat exchangers. To complete its review, the U.S. Nuclear Regulatory Commission (NRC) staff requests a response to the attached request for additional information.

If you have any questions please contact me at 301-415-1603.