i; August 22, 2011

~

,f'

~o Mr. David A Heacock President and Chief Nuclear Officer Dominion Nuclear Connecticut, Inc.

Innsbrook Technical Center SOOO Dominion Boulevard Glen Allen, VA 23060-6711

SUBJECT:

MILLSTONE POWER STATION, UNIT NO.3 - REVIEW OF THE 2010 STEAM GENERATOR TUBE INSERVICE INSPECTION REPORT (TAC NO. MES193)

Dear Mr. Heacock:

By letter dated October 28,2010, as supplemented by letter dated May 24,2011 (Agencywide Documents Access and Management System (ADAMS) Accession Nos. ML103130038 and ML 111S9A02S, respectively), Dominion Nuclear Connecticut, Inc. (DNC or the licensee),

submitted information summarizing the results of the 2010 steam generator tube inspections at Millstone Power Station, Unit NO.3 (MPS3). These inspections were performed during the thirteenth refueling outage.

The Nuclear Regulatory Commission (NRC) staff has completed its review of the information provided and concludes that DNC provided the information required by the MPS3 technical specifications and that no additional follow-up is required. The NRC's review is enclosed.

If you have any questions, please contact me at 301-41S-1603.

Carle J. Sanders, Project Manager Plant 'censing Branch 1-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. SO-423

Enclosure:

As stated cc wi end: Distribution via Listserv

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 REVIEW OF THE 2010 STEAM GENERATOR TUBE INSERVICE INSPECTION REPORT MILLSTONE POWER STATION, UNIT NO.3 DOCKET NUMBER 50-423 By letter dated October 28,2010, as supplemented by letter dated May 24,2011 (Agencywide Documents Access and Management System (ADAMS) Accession Nos. ML103130038 and ML11159A025, respectively), Dominion Nuclear Connecticut, Inc. (DNC or the licensee),

submitted information summarizing the results of the 2010 steam generator tube inspections at Millstone Power Station, Unit NO.3 (MPS3). These inspections were performed during the thirteenth refueling outage.

MPS3 has four Westinghouse Model F steam generators (SG), each of which contains 5,626 U bend thermally-treated Alloy 600 tubes. Each tube has a nominal outside diameter of 0.688 inches and a nominal wall thickness of 0.040 inches. During SG fabrication, the tubes were hydraulically expanded at both ends, over the full depth of the 21.23-inch thick tubesheet.

The U-bends in rows 1 through 10 were stress relieved after forming. Eight Type 405 stainless steel support plates, which have broached quatrefoil holes, support the vertical section of the tubes, and six anti-vibration bars support the U-bend section of the tubes.

As of the end of Cycle 13 (April 2010), the SGs had approximately 17.9 effective full-power years of operation. A 7% power uprate was implemented for Cycle 13. Prior to this implementation, MPS3 operated with a hot leg temperature of 617 0 F; after implementation, MPS3 operated with a hot leg temperature of 622 0 F.

DNC provided the scope, extent, methods, and results of their SG tube inspections in the documents referenced above. In addition, DNC described corrective actions (i.e., tube plugging) taken in response to the inspection findings.

After review of the information provided by the licensee, the NRC staff has the following observations/comments:

  • An upper bundle flush was performed in each of the four SGs.

Upper bundle inspections were performed in SG C. The erosion and corrosion damage of nozzles 1, 15, 16, and 30 in SG C has not advanced since the previous inspection.

These nozzles had an overlay applied during a previous outage. Some of the primary separator riser barrels in SG C showed minor erosion from overspray of the J-nozzles.

The erosion is considered minor and will be monitored during future inspections.

Based on a review of the information provided by DNC, the NRC staff concludes that DNC provided the information required by the MPS3 technical specifications. In addition, the SG tube Enclosure

-2 inspections at MPS3 appear to be consistent with the objective of detecting potential tube degradation and the inspection results appear to be consistent with industry operating experience at similarly-designed and operated units.

Principal Contributor: C. Hunt Date: August 22, 2011

August 22, 2011 Mr. David A. Heacock President and Chief Nuclear Officer Dominion Nuclear Connecticut, Inc.

Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711

SUBJECT:

MILLSTONE POWER STATION, UNIT NO.3 - REVIEW OF THE 2010 STEAM GENERATOR TUBE INSERVICE INSPECTION REPORT (TAC NO. ME5193)

Dear Mr. Heacock:

By letter dated October 28, 2010, as supplemented by letter dated May 24, 2011 (Agencywide Documents Access and Management System (ADAMS) Accession Nos. ML103130038 and ML11159A025, respectively), Dominion Nuclear Connecticut, Inc. (DNC or the licensee),

submitted information summarizing the results of the 2010 steam generator tube inspections at Millstone Power Station, Unit NO.3 (MPS3). These inspections were performed during the thirteenth refueling outage.

The Nuclear Regulatory Commission (NRC) staff has completed its review of the information provided and concludes that DNC provided the information required by the MPS3 technical specifications and that no additional follow-up is required. The NRC's review is enclosed.

If you have any questions, please contact me at 301-415-1603.

Sincerely, Ira!

Carleen J. Sanders, Project Manager Plant Licensing Branch 1-2 Division of Operating Reactor licenSing Office of Nuclear Reactor Regulation Docket No. 50-423

Enclosure:

As stated cc wI encl: Distribution via Listserv Distribution:

PUBLIC LPL 1-2 Reading RidsAcrsAcnw _MaiICTR Resource RidsNrrDorlLpl1-2 Resource RidsNrrDciCsgbResource RidsNrrLAABaxter Resource RidsNrrPMMilistone Resource RidsOgcRpMailCenter RidsRgn1 MailCenter Resource GMilier. EDO R-1 KKarwoski, NRR CHunt NRR RTaylor,NRR ADAMS Accesslon N0.:

ML112130189

"'Bsy Memo Dated OFFICE LPL 1-2/PM LPL 1-2/LA DCI/CSGB LPL1-2/BC LPL 1-2/PM

!NAME CSanders ABaxter RTaylor*

HChernoff (REnnis for)

CSanders

  • DATE 8/10/11 8/10/11 07/06/2011 8/22111 8/22/11 OFFICAL RECORD COPY