ES-401 MILLSTONE UNIT 3 Written Examination Review Worksheet Form ES-401-9

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q# LOK LOO (F/H) (1-5)

Stem Cues TlF Credo Partial Job-Minutia

  1. 1 Back-Q=

SRO B/M/N UlEtS Explanation Focus Oist.

Link units ward KIA Only 1

F 4

B S

2 H

3 N

S 3

H 3

B S

4 H

4 B

S 5

H 2

B S

6 H

4 N

S 7

H 2

A,B B

U A&B not plausible due to obvious pressure differential.

8 F

3 N

S Instructions

[Refer to Section 0 of ES-401 and Appendix B for additional information regarding each of the following concepts.)

1.

Enter the level of knowledge (LOK) of each question as either (F)undamental or (H)igher cognitive level.

2.

Enter the level of difficulty (LOO) of each question using a 1 5 (easy - difficult) rating scale (questions in the 2 - 4 range are acceptable).

3.

Check the appropriate box if a psychometric flaw is identified:

The stem lacks sufficient focus to elicit the correct answer (e.g., unclear intent, more information is needed, or too much needless information).

The stem or distractors contain cues (i.e., clues, specific determiners, phrasing, length, etc).

The answer choices are a collection of unrelated truelfalse statements.

The distractors are not credible; single implausible distractors should be repaired, more than one is unacceptable.

One or more distractors is (are) partially correct (e.g., if the applicant can make unstated assumptions that are not contradicted by stem).

4.

Check the appropriate box if a job content error is identified:

The question is not linked to the job requirements (i.e., the question has a valid KIA but, as written, is not operational in content).

The question requires the recall of knowledge that is too specific for the closed reference test mode (Le., it is not required to be known from memory).

The question contains data with an unrealistic level of accuracy or inconsistent units (e.g., panel meter in percent with question in gallons).

The question requires reverse logic or application compared to the job requirements.

S.

Check questions that are sampled *for conformance with the approved KIA and those that are designated SRO-only (KIA and license level mismatches are unacceptable).

6.

Enter question source: (Blank, (M)odified, or (N)ew. Check that (M)odified questions meet criteria of ES-401 Section 0.2.1.

7.

Based on the reviewer'S judgment, is the question as written (U)nsatisfactory (requiring repair or replacement), in need of (E)ditorial enhancement, or (S)atisfactory?

8.

At a minimum, explain any "U" ratings (e.g., how the Appendix B psychometric attributes are not being met).

ES-401 2

Form ES-401-9

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q#

LOK LOD (F/H)

(1-5)

Stem Cues TtF Credo Partial Job-Minutia

  1. 1 Back-Q; SRO B/M/N UtEtS Explanation Focus Dist.

Link units ward KIA Only 9

H 3

B S

10 H

2 A

B E

Replace A since both are obviously wrong for a LOOP.

11 F

2 A

B E

Replace A because there is no release to the atmosphere.

12 F

2 B

S 13 H

3 N

S 14 F

3 B

S 15 H

4 X

N E

Use load(s) vs load.

16 F

2 N

S 17 H

2 B,C B

U B & C not plausible. Replace.

18 H

2 N

S 19 H

3 N

S Fix 2nd sentence in explanation.

20 F

2 B

S 21 H

3 N

S 22 H

1 A,B A,B M

U Low LOD. A&B are the same. Fix Q or replace.

23 H

3 N

S 24 F

3 N

S 25 H

2 A

N E

A is not plausible.

26 H

2 B

S 27 H

4 B

S 28 F

3 N

S

ES-401 3

Form ES-401-9

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q#

LOK LOD (F/H)

(1-5)

Stem Cues T/F Credo Partial Job-Minutia

  1. 1 Back-Q=

SRO B/M/N UtE/S Explanation Focus Dist.

Link units ward KIA Only 29 H

2 N

S 30 F

3 N

S 31 H

2 X

B E

Capitalize will" in A & C.

32 F

2 N

S 33 F

2 B

S 34 H

2 B,D N

U B&D questionable plausibility - modify.

35 F

2 X

N E

Add bullet stating that systems respond normally.

36 H

2 B

S 37 H

3 X

N E

Delete "due to an automatic reactor trip."

38 H

3 B

S 39 H

2 A,B N

U Add inadvertent CIA to complicate system response and effect.

40 H

3 X

B U

There is no effect due to the loss of QS. Reselect or replace Q.

41 H

2 N

S 42 H

3 B

S 43 H

3 N

S 44 F

2 B

S 45 H

3 B

S 46 F

3 B

S 47 H

2 N

S 1118 F

2 8

S

ES-401 4

Form ES-401-9

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q#

LOK LOD (F/H)

(1-5)

Stem Cues T/F Credo Partial Job-Minutia

  1. /

Back-Q=

SRO B/M/N UtE/S Explanation Focus Dist.

Link units ward KIA Only 49 H

3 B

S 50 F

2 B

S 51 H

3 B

S 52 F

3 N

S Fix explanation to specify C vs D is correct.

53 F

2 N

S 54 H

2 N

S 55 F

3 N

S 56 H

2 B

S 57 H

3 B

S 58 H

3 M

S 59 F

2 A

N E

Add humidity level to stem to ensure only one correct response.

60 F

2 B

S 61 H

2 B

S 62 F

1 X

N U

Ask question about a specific ARM to increase LOD.

63 H

2 X

N E

Remove 4th bullet. Modify stem. Delete unneeded words in A-D.

64 F

2 A,C N

U Reselect due to difficulty in writing discriminating Q for KIA.

65 H

3 X

B E

Delete "in about 25 seconds" from A& 8.

66 F

3 B

N E

8 not plausible - somebody has to keep track of implementation.

67 F

3 N

S

~Q~8 H

3 B

S

ES-401 5

Form ES-401-9

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q#

LOK LOD (F/H)

(1-5)

Stem Cues T/F Credo Partial Job-Minutia

  1. 1 Back-Q=

SRO B/M/N utE/S Explanation Focus Dist.

Link units ward KIA Only 69 F

3 N

S 70 F

2 N

S 71 F

3 C

N E

C not plausible due to "exit." Replace if possible.

72 F

2 N

S Expand explanation wrt to meeting KIA.

73 F

1 N

U Reselect due to limited symbol usage in EOPs.

74 H

2 N

S Expand explanation wrt to meeting KIA.

75 H

2 X

B U

Need to use reference material to meet KIA.

76 H

2 A,C N

U A & C not plausible. Change increase to "stop feeding."

77 H

2 X

B E

Delete 3rd bullet and add "lAW procedure xxxxx" to C & D.

78 H

3 B

S Expand explanation for not entering FR-H.1.

79 H

2 X

B E

Delete 4th bullet. Simplify question. Edit distracters.

80 H

3 D

N E

Replace second part of D to make more plausible.

81 H

2 B

S 82 H

2 X

N E

Edit 2nd bullet. Add corrective actions to C & D.

83 H

3 N

S 84 H

3 B

S 85 H

3 X

B E

Add "lAW xxx" to A & B.

86 H

3 N

S

ES-401 6

Form ES-401-9 Q#

1.

LOK

2.

LOD

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

(F/H)

(1-5)

Stem Cues T/F Credo Partial Job-Minutia

  1. /

Back-Q=

SRO B/M/N U/E/S Explanation Focus Dist.

Link units ward KIA Only 87 H

3 B

S 88 H

4 X

N E

Delete "if any." Provide permissive light status for additions info.

89 H

2 N

S 90 H

3 N

S 91 H

2 B

S 92 H

3 X

B E

Correct psig vs gpm in explanation.

93 H

2 B

S 94 H

2 B

S 95 F

2 B,C B

U Find more plausible distracters for B & C.

96 H

2 B

S 97 F

2 X

B B

E Add "one" to C and change to OR. Replace B with TS 3.10.

98 F

2 X

B U

Not SRO-only. Can be answered by systems knowledge. Replace.

99 H

2 B

S 100 H

2 N

S