ML11187A348

From kanterella
Jump to navigation Jump to search
OL - TVA Letter to NRC_06-21-11_2-PTI-030I-01 Transmittal to NRC
ML11187A348
Person / Time
Site: Watts Bar Tennessee Valley Authority icon.png
Issue date: 06/22/2011
From:
- No Known Affiliation
To:
Division of Operating Reactor Licensing
References
Download: ML11187A348 (168)


Text

1 WBN2Public Resource From:

Boyd, Desiree L [dlboyd@tva.gov]

Sent:

Wednesday, June 22, 2011 8:51 AM To:

Epperson, Dan; Poole, Justin; Raghavan, Rags; Milano, Patrick; Campbell, Stephen Cc:

Crouch, William D; Hamill, Carol L; Boyd, Desiree L

Subject:

TVA letter to NRC_06-21-11_2-PTI-030I-01 transmittal to NRC Attachments:

06-21-11_2-PTI-030I-01 transmittal to NRC_Final.pdf PleaseseeattachedTVAletterthatwassenttotheNRCtoday.

ThankYou,

~*~*~*~*~*~*~*~*~*~*~*~

Désireé L. Boyd WBN2LicensingSupport SunTechnicalServices dlboyd@tva.gov 4233658764

Hearing Identifier:

Watts_Bar_2_Operating_LA_Public Email Number:

432 Mail Envelope Properties (7AB41F650F76BD44B5BCAB7C0CCABFAF202774B7)

Subject:

TVA letter to NRC_06-21-11_2-PTI-030I-01 transmittal to NRC Sent Date:

6/22/2011 8:51:11 AM Received Date:

6/22/2011 8:51:46 AM From:

Boyd, Desiree L Created By:

dlboyd@tva.gov Recipients:

"Crouch, William D" <wdcrouch@tva.gov>

Tracking Status: None "Hamill, Carol L" <clhamill@tva.gov>

Tracking Status: None "Boyd, Desiree L" <dlboyd@tva.gov>

Tracking Status: None "Epperson, Dan" <Dan.Epperson@nrc.gov>

Tracking Status: None "Poole, Justin" <Justin.Poole@nrc.gov>

Tracking Status: None "Raghavan, Rags" <Rags.Raghavan@nrc.gov>

Tracking Status: None "Milano, Patrick" <Patrick.Milano@nrc.gov>

Tracking Status: None "Campbell, Stephen" <Stephen.Campbell@nrc.gov>

Tracking Status: None Post Office:

TVANUCXVS2.main.tva.gov Files Size Date & Time MESSAGE 308 6/22/2011 8:51:46 AM 06-21-11_2-PTI-030I-01 transmittal to NRC_Final.pdf 541851 Options Priority:

Standard Return Notification:

No Reply Requested:

No Sensitivity:

Normal Expiration Date:

Recipients Received:

U.S. Nuclear Regulatory Commission Page 2 June 21, 2011 bcc (Enclosure):

Stephen Campbell U.S. Nuclear Regulatory Commission MS 08H4A One White Flint North 11555 Rockville Pike Rockville, Maryland 20852-2738 Charles Casto, Deputy Regional Administrator for Construction U. S. Nuclear Regulatory Commission Region II Marquis One Tower 245 Peachtree Center Ave., NE Suite 1200 Atlanta, Georgia 30303-1257

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 3 of 164 Table of Contents

1.0 INTRODUCTION

.......................................................................................................... 5 1.1 Test Objectives............................................................................................................. 5 1.2 Scope............................................................................................................................ 5

2.0 REFERENCES

............................................................................................................. 7 2.1 Performance References.............................................................................................. 7 2.2 Developmental References........................................................................................... 7 3.0 PRECAUTIONS AND LIMITATIONS......................................................................... 14 4.0 PREREQUISITE ACTIONS........................................................................................ 16 4.1 Preliminary Actions..................................................................................................... 16 4.2 Special Tools, Measuring and Test Equipment, Parts, and Supplies.......................... 19 4.3 Field Preparations....................................................................................................... 20 4.4 Approvals and Notifications........................................................................................ 27 5.0 ACCEPTANCE CRITERIA......................................................................................... 28 6.0 PERFORMANCE........................................................................................................ 33 6.1 CRDM Cooler Dampers Logic Test............................................................................ 34 6.1.1 2-TCO-30-84, CRDM Cooler 2A-A Shroud Suction...................................... 34 6.1.2 2-TCO-30-85, CRDM Cooler 2A-A Lower Containment Suction................... 38 6.1.3 2-TCO-30-93, CRDM Cooler 2B-B Shroud Suction...................................... 42 6.1.4 2-TCO-30-94, CRDM Cooler 2B-B Lower Containment Suction................... 46 6.1.5 2-TCO-30-89, CRDM Cooler 2C-A Shroud Suction...................................... 50 6.1.6 2-TCO-30-90, CRDM Cooler 2C-A Lower Containment Suction.................. 54 6.1.7 2-TCO-30-81, CRDM Cooler 2D-B Shroud Suction...................................... 58 6.1.8 2-TCO-30-82, CRDM Cooler 2D-B Lower Containment Suction.................. 62 6.2 CRDM Cooler Logic Test............................................................................................ 66 6.2.1 CRDM Cooler 2A-A Logic............................................................................. 66 6.2.2 CRDM Cooler 2B-B Logic............................................................................. 80 6.2.3 CRDM Cooler 2C-A Logic............................................................................. 94 6.2.4 CRDM Cooler 2D-B Logic........................................................................... 108

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 4 of 164 Table of Contents (continued) 6.3 CRDM Coolers Response to Phase B Containment Isolation Signal........................ 122 6.3.1 Train A CRDM Coolers (2A-A and 2C-A).................................................... 122 6.3.2 Train B CRDM Coolers (2B-B and 2D-B).................................................... 127 6.4 CRDM Coolers Response To Bus Undervoltage...................................................... 131 6.4.1 CRDM Cooler 2A-A..................................................................................... 131 6.4.2 CRDM Cooler 2B-B..................................................................................... 135 6.4.3 CRDM Cooler 2C-A.................................................................................... 138 6.4.4 CRDM Cooler 2D-B.................................................................................... 141 6.5 CRDM Coolers Auto-Start on Low Air Flow.............................................................. 144 6.5.1 CRDM Coolers 2A-A and 2D-B................................................................... 144 6.5.2 CRDM Coolers 2B-B and 2C-A................................................................... 148 6.6 CRDM Coolers Air Flow............................................................................................ 151 7.0 POST PERFORMANCE ACTIVITY.......................................................................... 153 8.0 RECORDS................................................................................................................ 153 Appendix A:

TEST PROCEDURES/INSTRUCTIONS REFERENCE REVIEW................................................................................................... 154 Appendix B:

TEMPORARY CONDITION LOG............................................................. 155 Appendix C:

PERMANENT PLANT INSTRUMENTATION LOG.................................. 156 Appendix D:

SWITCH LINEUP..................................................................................... 158 Appendix E:

POWER LINEUP...................................................................................... 161

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 5 of 164 Data Package: Page ____ of ____

Date ________

1.0 INTRODUCTION

1.1 Test Objectives A.

Demonstrate the proper operation of the Control Rod Drive Mechanism (CRDM)

Cooling Units and Dampers.

B.

Demonstrate the proper operation of the Essential Raw Cooling Water (ERCW) control valves associated with each CRDM Cooler.

1.2 Scope NOTES

1) 2-PTI-030L-01, HFT Containment Temperature Survey, will demonstrate the CRDM Coolers ability to maintain design temperatures.
2)

ERCW flowrates are verified during performance of 2-PTI-067-02-A and 2-PTI-067-02-B, ERCW System Flow Balance Train A and Train B.

3)

ERCW Temperature Control Valves logic is tested during performance of 2-PTI-067-03, ERCW Valve Logic Test.

4)

System vibration testing is performed during performance of GTM-05, HVAC Air Balance for this system.

This test demonstrates the operability of the Unit 2 CRDM Coolers to ensure the following:

A.

CRDM Cooler Dampers

1.

The CRDM Cooler Dampers operate correctly from their respective handswitches in the Main Control Room and Auxiliary Control Room, and their indicating lights indicate correct status.

2.

The required CRDM Cooler Dampers (shroud suction dampers) open and close upon start/stop of their respective CRDM Cooler.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 6 of 164 Data Package: Page ____ of ____

Date ________

1.2 Scope (continued)

B.

CRDM Cooler Units

1.

The CRDM Coolers operate correctly from their respective handswitches in the Main Control Room and on the 480V Shutdown Boards, and their indicating lights indicate correct status.

2.

Each CRDM Cooler stops on a simulated Phase B Containment Isolation Signal, and remains off when that signal is reset.

3.

Each CRDM Cooler stops on a simulated Bus Undervoltage condition.

4.

The inlet and outlet air temperatures for each CRDM Cooler can be monitored on the Plant Computer System.

5.

The CRDM Coolers maintain design air flows.

6.

Each ERCW control valve modulates open upon start and closes upon stop of its associated CRDM Cooler.

7.

The following features function only when the CRDM Coolers Transfer Switch is in AUX:

a.

Each CRDM Cooler can be started manually while a simulated Phase B Containment Isolation Signal is present.

b.

Each CRDM Cooler restarts after a time delay when a simulated Bus Undervoltage condition is restored.

c.

Each CRDM Cooler starts on a low flow condition in the other CRDM Cooler with which it is paired.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 7 of 164 Data Package: Page ____ of ____

Date ________

2.0 REFERENCES

2.1 Performance References A.

SMP-9.0. Conduct of Test B.

GTM-05, HVAC Air Balance C.

0-SOI-67.01, Essential Raw Cooling Water D.

2-SOI-30.03, Containment HVAC and Pressure Control 2.2 Developmental References A.

Final Safety Analysis Report, Amendment 104

1.

Section 9.2.1, Essential Raw Cooling Water (ERCW)

2.

Section 9.4.7, Containment Air Cooling System

3.

Table 14.2-1, Sheets 4 & 5, Essential Raw Cooling Water System Test Summary

4.

Table 14.2-1, Sheets 38 & 39, Containment Ventilation System Test Summary B.

Drawings

1.

Flow Diagrams

a.

2-47W866-1, Rev 2, HEATING AND VENTILATION AIR FLOW DRA 53850-001, Rev 0 DRA 53850-002, Rev 0 DRA 54923-038, Rev 0 DRA 54923-039, Rev 0

b.

2-47W845-3, Rev 2, ESSENTIAL RAW COOLING WATER

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 8 of 164 Data Package: Page ____ of ____

Date ________

2.2 Developmental References (continued)

2.

Electrical

a.

2-45W760-30-8, Rev 1, VENTILATING SYSTEM SCHEMATIC DIAGRAMS DRA 54172-032, Rev 0 DRA 54172-034, Rev 0 DRA 54172-070, Rev 0 DRA 54172-071, Rev 0

b.

2-45W760-30-26, Rev 1, VENTILAING SYSTEM SCHEMATIC DIAGRAMS DRA 54172-074, Rev 0 DRA 54172-075, Rev 0

c.

45W760-30-21, Rev 11, VENTILATING SYSTEM SCHEMATIC DIAGRAMS

d.

45W760-55-1, Rev 6, ANNUNCIATOR SYSTEM SCHEMATIC DIAGRAMS

e.

45W760-55-2, Rev 7, ANNUNCIATOR SYSTEM SCHEMATIC DIAGRAMS DRA 52639-76, Rev 0

f.

2-45W600-30-1, Rev 0, VENTILATING SYSTEM SCHEMATIC DIAGRAMS DRA 54172-120, Rev 0 DRA 54172-121, Rev 0 DRA 54172-122, Rev 0 DRA 54172-123, Rev 0

g.

2-45W600-30-2, Rev 0, VENTILATING SYSTEM SCHEMATIC DIAGRAMS

h.

2-45W600-57-9, Rev 0, SEPARATION & MISC AUX RELAYS SCHEMATIC DIAGRAMS

i.

2-45W600-57-18, Rev 1, SEPARATION & MISC AUX RELAYS SCHEMATIC DIAGRAMS

j.

2-45W600-57-20, Rev 0, SEPARATION & MISC AUX RELAYS SCHEMATIC DIAGRAMS

k.

2-45W600-57-21, Rev 0, SEPARATION & MISC AUX RELAYS SCHEMATIC DIAGRAMS

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 9 of 164 Data Package: Page ____ of ____

Date ________

2.2 Developmental References (continued)

l.

2-45W600-67-1, Rev 0, ESSENTIAL RAW COOLING WATER SYS SCHEMATIC DIAGRAM

m. 2-45W600-67-2, Rev 0, ESSENTIAL RAW COOLING WATER SCHEMATIC DIAGRAM
n.

1-45W760-212-4, Rev 16, 480V SHUTDOWN POWER SCHEMATIC DIAGRAMS

o.

2-45W749-1, Rev 1, 480V SHUTDOWN BD 2A1-A DRA 54172-017, Rev 0 DRA 54172-068, Rev 0

p.

2-45W749-2, Rev 1, 480V SHUTDOWN BD 2A2-A DRA 54172-018, Rev 0 DRA 54172-069, Rev 0

q.

2-45W749-3, Rev 1, 480V SHUTDOWN BD 2B1-B DRA 54172-019, Rev 0 DRA 54172-067, Rev 0

r.

2-45W749-4, Rev 2, 480V SHUTDOWN BD 2B2-B DRA 54172-020, Rev 0 DRA 54172-066, Rev 0

s.

45W2748-1, Rev 13, 480V SHUTDOWN BD 2A1-A CONNECTION DIAGRAMS DRA 54172-021, Rev 0 DRA 54172-265, Rev 0

t.

45W2748-2, Rev 12, 480V SHUTDOWN BD 2A2-A CONNECTION DIAGRAMS DRA 54172-022, Rev 0 DRA 54172-266, Rev 0

u.

45W2748-3, Rev 14, 480V SHUTDOWN BD 2B1-B CONNECTION DIAGRAMS DRA 54172-023, Rev 0 DRA 54172-267, Rev 0

v.

45W2748-4, Rev 12, 480V SHUTDOWN BD 2B2-B CONNECTION DIAGRAMS DRA 54172-024, Rev 0 DRA 54172-268, Rev 0

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 10 of 164 Data Package: Page ____ of ____

Date ________

2.2 Developmental References (continued)

w.

45N2676-4, Rev 16, SOLID STATE PROTECTION SYS TRAIN A CONNECTION DIAGRAM

x.

45N2677-4, Rev 18, SOLID STATE PROTECTION SYS TRAIN B CONNECTION DIAGRAM

y.

6947D02 (AC), Rev G, LVME DS SWGR 480V 3PH 60HZ SUBSTATION INTERNALS

z.

618F938, Rev 913, LVME DS SWGR 480V SHUTDOWN BD 2A1-A 480V 3PH 60HZ SUBSTATION CONN DIAG UNIT 6 DRA 53066-027, Rev 0 DRA 53066-031, Rev 0 DRA 53068-031, Rev 0 aa. 618F938 (AC), Rev F, LVME DS SWGR 480V SHUTDOWN BD 2A1-A 480V 3PH 60HZ SUBSTATION CONN DIAG UNIT 6 bb. 6947D67, Rev 915, LVME DS SWGR 480V SHUTDOWN BD 2A2-A 480V 3PH 60HZ SUBSTATION CONN DIAG UNIT 6 DRA 53067-012, Rev 1 DRA 53067-015, Rev 0 DRA 53068-034, Rev 0 cc. 6947D67 (AC), Rev K, LVME DS SWGR 480V SHUTDOWN BD 2A2-A 480V 3PH 60HZ SUBSTATION CONN DIAG UNIT 6 dd. 618F941, Rev 913, LVME DS SWGR 480V SHUTDOWN BD 2B1-B 480V 3 60HZ SUBSTATION CONN DIAG UNIT 6 DRA 53068-010, Rev 0 DRA 53068-015, Rev 0 ee. 618F941 (AC), Rev F, LVME DS SWGR 480V SHUTDOWN BD 2B1-B 480V 3 60HZ SUBSTATION CONN DIAG UNIT 6 ff.

6947D85, Rev 915, LVME DS SWGR 480V SHUTDOWN BD 2B2-B 480V 3 60HZ SUBSTATION CONN DIAG UNIT 6 DRA 53069-010, Rev 0 DRA 53069-016, Rev 0 gg. 6947D85 (AC), Rev H, LVME DS SWGR 480V SHUTDOWN BD 2B2-B 480V 3 60HZ SUBSTATION CONN DIAG UNIT 6

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 11 of 164 Data Package: Page ____ of ____

Date ________

2.2 Developmental References (continued)

3.

Logic/Control

a.

2-47W610-30-2, Rev 1, CONTROL DIAGRAM VENTILATION SYSTEM DRA 54172-287, Rev 0 DRA 54172-288, Rev 0 DRA 54172-289, Rev 0 DRA 54172-290, Rev 0

b.

2-47W610-67-2, Rev 1, CONTROL DIAGRAM ERCW SYSTEM

c.

2-47W611-30-4, Rev 1, LOGIC DIAGRAM VENTILATION SYSTEM DRA 54172-282, Rev 0

d.

2-47W611-67-3, Rev 1, LOGIC DIAGRAM ESSENTIAL RAW COOLING WATER

4.

Other

a.

2-47W600-171, Rev 0, ELECTRICAL INSTRUMENT AND CONTROLS DRA 53630-004, Rev 0 DRA 53630-046, Rev 1

b.

2-47B601-55-1, ELECTRICAL INSTRUMENT TABULATION [Later]

DRA 52453-04, Rev 0

c.

2-47B601-55-2, ELECTRICAL INSTRUMENT TABULATION [Later]

DRA 52453-05, Rev 0

d.

2-47B601-55-3, ELECTRICAL INSTRUMENT TABULATION [Later]

DRA 52453-06, Rev 0

e.

2-47B601-55-4, ELECTRICAL INSTRUMENT TABULATION [Later]

DRA 52453-07, Rev 0

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 12 of 164 Data Package: Page ____ of ____

Date ________

2.2 Developmental References (continued)

f.

2-45B655-5C, Rev 0, ANNUNCIATOR INPUTS WINDOW BOX XA-55-5C

g.

2-45B655-E5C, Rev 0, ANNUNCIATOR WINDOW BOX XA-55-5C ENGRAVING

h.

2-45B655-6E, Rev 0, ANNUNCIATOR INPUTS WINDOW BOX XA-55-6E DCA 52630-091, Rev 0

i.

2-45B655-E6E, Rev 0, ANNUNCIATOR WINDOW BOX XA-55-6E ENGRAVING

j.

2-45B655-6F, Rev 0, ANNUNCIATOR INPUTS WINDOW BOX XA-55-6F DRA 52343-236, Rev 0 DCA 52630-092, Rev 0

k.

2-45B655-E6F, Rev 0, ANNUNCIATOR WINDOW BOX XA-55-6F ENGRAVING

5.

Vendor Manuals

a.

VM-F180-3066, Rev 0, Foxboro Instruction Book 3473 743CB Field Station Micro Controller

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 13 of 164 Data Package: Page ____ of ____

Date ________

2.2 Developmental References (continued)

C.

Documents

1.

GTM-05, HVAC Air Balance (Draft)

2.

WBN2-30RB-4002, Rev 1, Reactor Building Ventilation System

3.

G-37, Rev 4, Testing and Balancing of HVAC Systems During Installation, Modification, and Maintenance

4.

2-TSD-30I-1, Rev 1, Containment Air Cooling System - Control Rod Drive Mechanism Coolers

5.

2-PTI-030L-01, HFT Containment Temperature Survey (Draft)

6.

2-PTI-067-02-A, Rev 0, ERCW System Flow Balance - Train A

7.

2-PTI-067-02-B, Rev 0, ERCW System Flow Balance - Train B

8.

2-PTI-067-03, ERCW Valve Logic Test (Draft)

9.

MI-57.002, Rev 39, Westinghouse DS Circuit Breaker Routine Maintenance, Inspection and Testing

10. SSD-2-LPT-67-85, Rev 0, Control Rod Drive Vent Cooler A Temp
11. SSD-2-LPT-67-101, Rev 0, Control Rod Drive Vent Cooler B Temp
12. SSD-2-LPT-67-93, Rev 0, Control Rod Drive Vent Cooler C Temp
13. SSD-2-LPT-67-109, Rev 0, Control Rod Drive Vent Cooler D Temp

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 14 of 164 Data Package: Page ____ of ____

Date ________

3.0 PRECAUTIONS AND LIMITATIONS A.

Standard precautions shall be followed for working around energized electrical equipment in accordance with TVA Safety Procedure 1021.

B.

Steps may be repeated if all components cannot be tested in a step. However, if the test has been exited, prerequisite steps must be re-verified and a Chronological Test Log (CTL) entry made.

C.

Discrepancies between component ID tags and the description in a procedure/instruction if the UNIDs match, exclusive of place keeping zeros and train designators (e.g.; 2-HS-31-468 vs. 2-HS-031-0468) and the noun description is sufficient to identify the component. This condition does not require a Test Deficiency Notice (TDN) in accordance SMP-14.0. If the component label needs to be changed, a Tag Request Form (TR Card) should be processed in accordance with TI-12.14. Make an entry in the CTL and continue testing.

D.

IF/THEN steps may be marked N/A if stated condition does not exist.

E.

All wires removed/lifted from a terminal shall be identified and taped or covered with an insulator to prevent personnel or equipment hazard and possible spurious initiations. The wires should be grouped together and labeled with the work implementing document number that required them to be lifted if left unattended.

F.

All terminal points and connections are to be considered energized.

Instrumentation must be used to determine if the circuits are de-energized.

G. Retermination of lifted leads requires that their restored bend radius is equal to or greater than the as-found condition.

H.

CRDM Cooler Circuit Breakers have Overload Trip Switch (OTS) reset coils.

Placing the Handswitch to STOP will energize the OTS Reset Coil and reset the OTS. The OTS Reset Coil should only be energized momentarily; the OTS contact in series with the coil should open to de-energize the coil. To avoid overheating the coil, do not hold Handswitch in STOP if the coil does not de-energize.

I.

When installing fuses with actuators, ensure that the actuating rod is oriented correctly to provide for proper alarm initiation and visual indication.

J.

All open problems are to be tracked by a corrective action document and entered on the appropriate system punchlist.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 15 of 164 Data Package: Page ____ of ____

Date ________

3.0 PRECAUTIONS AND LIMITATIONS (continued)

K.

Problems identified during the test shall be annotated on the CTL, including a description of the problem, the procedure step when/where the problem was identified, corrective action steps taken to resolve the problem, and the number of the corrective action document, if one was required.

L.

Observe all Radiation Protection requirements when working in or near contaminated areas.

M. Ensure there are no adverse effects to the operation of Unit 1 structures, systems, or components.

N.

Vibration testing of this system is performed during GTM-05, HVAC Air Balance for this system.

O. During the performance of this procedure, visual observation of fans and ductwork is required. This includes steady-state and transient operations (fan starts and stops) with visual confirmation that vibration is not excessive.

P.

To verify that transient conditions are not causing excessive vibration, observe components (duct, dampers, fans, etc) during the transient, to the extent practical. If not practical to observe during the transient, verify after the transient that no damage has occurred.

Q. If the vibration is determined to be excessive, the Test Engineer shall initiate a TDN.

R.

Operation of CRDM Cooler Fans could create a local personnel hazard due to high noise levels, high air velocity, and the possibility of flying debris. Ensure personnel and loose equipment are clear of fan discharge and that personnel in the area are cognizant of expected fan start prior to starting a CRDM Cooler.

S.

CRDM Cooler control switches in the Main Control Room may NOT be placed in PULL A-P AUTO. Auto-start features enabled by this switch position are disabled and are not tested in this instruction.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 16 of 164 Data Package: Page ____ of ____

Date ________

4.0 PREREQUISITE ACTIONS NOTE Prerequisite steps may be performed in any order, unless otherwise stated, and should be completed as close in time as practicable to the start of the instruction subsection to which they apply.

4.1 Preliminary Actions

[1]

VERIFY the test/performance copy of this Preoperational Test Instruction (PTI) is the current revision and as needed, each test person assisting in this test has the current revision.

[2]

OBTAIN copies of the applicable forms from the latest revision of SMP-9.0, AND ATTACH to this PTI for use during the performance of this PTI.

[3]

ENSURE changes to the references listed on Appendix A have been reviewed, and determined NOT to adversely affect the test performance.

[4]

VERIFY current revisions and change paper for referenced drawings have been reviewed and determined NOT to adversely affect the test performance, AND ATTACH documentation of the current drawing revision numbers and change papers that were reviewed to the data package.

[5]

ENSURE components contained within the boundaries of this test are under the jurisdictional control of Preoperational Startup Engineering (PSE) and/or Plant Operations.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 17 of 164 Data Package: Page ____ of ____

Date ________

4.1 Preliminary Actions (continued)

[6]

EVALUATE open items in Watts Bar Integrated Task Equipment List (WITEL), AND ENSURE that they will NOT adversely affect the test performance.

A.

Section 6.1 B.

Section 6.2 C.

Section 6.3 D.

Section 6.4 E.

Section 6.5 F.

Section 6.6

[7]

ENSURE required Component Testing has been completed prior to start of test.

A.

Section 6.1 B.

Section 6.2 C.

Section 6.3 D.

Section 6.4 E.

Section 6.5 F.

Section 6.6

[8]

ENSURE outstanding Design Change Notices (DCNs),

Engineering Document Construction Releases (EDCRs), or Temporary Alterations (TAs) do NOT adversely impact testing, AND ATTACH documentation of DCNs, EDCRs, and TAs that were reviewed to the data package.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 18 of 164 Data Package: Page ____ of ____

Date ________

4.1 Preliminary Actions (continued)

[9]

ENSURE GTM-05, HVAC Air Balance, has been submitted to the Joint Test Group (JTG) for concurrence that it adequately satisfies the requirements of this instruction.

JTG Meeting Number: ________________

[10]

ATTACH completed GTM-05 HVAC Air Balance Package for system 30I to this instruction.

[11]

ENSURE a review of outstanding Clearances has been coordinated with Unit 2 Operations for impact to the test performance, AND RECORD in Appendix B, Temporary Condition Log if required.

[12]

VERIFY plant instruments required for test performance have been placed in service and are within their calibration interval, AND RECORD on Appendix C, Permanent Plant Instrumentation Log.

A.

Section 6.2 B.

Section 6.5

[13]

REVIEW preventive maintenance records for equipment within the scope of this test, AND VERIFY no conditions exist that will impact test performance.

A.

Section 6.1 B.

Section 6.2 C.

Section 6.3 D.

Section 6.4 E.

Section 6.5

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 19 of 164 Data Package: Page ____ of ____

Date ________

4.1 Preliminary Actions (continued)

[14]

PERFORM a pretest walkdown on equipment to be tested to ensure no conditions exist that will impact test performance.

A.

Section 6.1 B.

Section 6.2 C.

Section 6.3 D.

Section 6.4 E.

Section 6.5

[15]

CONDUCT a pretest briefing with Test and Operations personnel in accordance with SMP-9.0.

[16]

ENSURE that communications are available for areas where testing is to be conducted.

4.2 Special Tools, Measuring and Test Equipment, Parts, and Supplies

[1]

ENSURE the following are available:

A.

Switched Jumpers [2]

B.

Handheld Jumper [1]

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 20 of 164 Data Package: Page ____ of ____

Date ________

4.3 Field Preparations

[1]

ENSURE the following systems are operable and have been placed in service to the extent necessary to perform this test:

A.

System 32, Control Air B.

System 55, Annunciator and Sequential Events Recording System C.

System 67, Essential Raw Cooling Water D.

System 99, Reactor Protection System E.

System 212, 480V Shutdown Power F.

System 235, 120V AC Vital Power System G. System 236, 125V DC Vital Power System H.

System 291, Integrated Computer System (ICS)

[2]

ENSURE the following ICS points are in scan:

A.

HD2030, VENT SYS HS-38A, 88A, 74A, 77A, 83A B.

HD2064, VENT SYS HS-39A, 78A, 75A, 92A, 80A C.

T1100A, CRDM COOL UNIT A-A EXHAUST D.

T1101A, CRDM COOL UNIT B-B EXHAUST E.

T1102A CRDM COOL UNIT C-A EXHAUST F.

T1103A CRDM COOL UNIT D-B EXHAUST G. T1104A CRDM COOL UNIT C-A B-B INTAKE H.

T1105A CRDM COOL UNIT A-A D-B INTAKE

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 21 of 164 Data Package: Page ____ of ____

Date ________

4.3 Field Preparations (continued)

NOTES

1)

Any Annunciator points associated with 2-MUX-55-12 and 2-MUX-55-13 ONLY have master switches at the bottom of each terminal strip.

2)

All points associated with 2-TBK-55-25, 2-TBK-55-26, 2-TBK-55-27, and 2-TBK-55-28 will not have individual switches or a master switch.

[3]

ENSURE System 55, Annunciator and Sequential Events Recording System, applicable TBK Switches are ON, the applicable Master Switches are ON, and window software input(s) are ENABLED for the following Annunciator Windows:

A.

2-XA-55-5C-102A, CRDM COOLER FLOW LO B.

2-XA-55-6E-138E, PANEL M-9 MOTOR TRIPOUT C.

2-XA-55-6F-148B, ACR PNL 2-L-11A D.

2-XA-55-6F-148C, ACR PNL 2-L-11B E.

2-XA-55-6F-149B, 480 SD BD 2A1-A/2A2-A/CA VT BD 2A1-A F.

2-XA-55-6F-150B, 480 SD BD 2B1-B/2B2-B/CA VT BD 2B1-B

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 22 of 164 Data Package: Page ____ of ____

Date ________

4.3 Field Preparations (continued)

[4]

ENSURE Essential Raw Cooling Water Temperature Control Valves (TCVs) and Temperature Indicating Controllers (TICs) are available to support test activities.

A.

2-TCV-67-85, CRD VENT CLR 2A-A OUT TEMP CNTL (Subsection 6.2.1)

B.

2-TIC-67-85, CRD VENT CLR 2A OUT TEMP CNTL (Subsection 6.2.1)

C.

2-TCV-67-101, CRD VENT CLR 2B-B OUT TEMP CNTL (Subsection 6.2.2)

D.

2-TIC-67-101, CRD VENT CLR 2B OUT TEMP CNTL (Subsection 6.2.2)

E.

2-TCV-67-93, CRD VENT CLR 2C-A OUT TEMP CNTL (Subsection 6.2.3)

F.

2-TIC-67-93, CRD VENT CLR 2C OUT TEMP CNTL (Subsection 6.2.3)

G. 2-TCV-67-109, CRD VENT CLR 2D-B OUT TEMP CNTL (Subsection 6.2.4)

H.

2-TIC-67-109, CRD VENT CLR 2D OUT TEMP CNTL (Subsection 6.2.4)

[5]

ENSURE ERCW system is aligned per 0-SOI-67.01 and/or 2-SOI-30.03, as applicable to support test performance.

(Section 6.2)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 23 of 164 Data Package: Page ____ of ____

Date ________

4.3 Field Preparations (continued)

[6]

RECORD the As-Found position of the following ERCW Temperature Indicating Controllers Auto/Manual (A/M) Status, Setpoints and Outputs on Panel 2-L-26,

[A15U/692 (Pent Rm)]:

A.

2-TIC-67-85, CRD VENT CLR 2A OUT TEMP CNTL (SubSection 6.2.1)

Auto/Manual Status:

Indicated Controller Setpoint:

Indicated Controller Output:

B.

2-TIC-67-101, CRD VENT CLR 2B OUT TEMP CNTL (SubSection 6.2.2)

Auto/Manual Status:

Indicated Controller Setpoint:

Indicated Controller Output:

C.

2-TIC-67-93, CRD VENT CLR 2C OUT TEMP CNTL (SubSection 6.2.3)

Auto/Manual Status:

Indicated Controller Setpoint:

Indicated Controller Output:

D.

2-TIC-67-109, CRD VENT CLR 2D OUT TEMP CNTL (SubSection 6.2.4)

Auto/Manual Status:

Indicated Controller Setpoint:

Indicated Controller Output:

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 24 of 164 Data Package: Page ____ of ____

Date ________

4.3 Field Preparations (continued)

[7]

ENSURE the following system 67, ERCW Temperature Indicating Controllers on Panel 2-L-26, Auto/Manual Status is in Manual (M) and outputs are adjusted for maximum cooling (valve full open):

A.

2-TIC-67-85, CRD VENT CLR 2A TEMP CNTL (SubSection 6.2.1)

B.

2-TIC-67-101, CRD VENT CLR 2B TEMP CNTL (SubSection 6.2.2)

C.

2-TIC-67-93, CRD VENT CLR 2C TEMP CNTL (SubSection 6.2.3)

D.

2-TIC-67-109, CRD VENT CLR 2D OUT TEMP CNTL (SubSection 6.2.4)

[8]

VERIFY there are no Unit 2 Phase B Containment Isolation Signals present by the B window NOT LIT on either the TR-A or TR-B MASTER ISOL SIGNAL STATUS PNL (Window 3 on 2-XX-55-6C and 2-XX-55-6D) on 2-M-6.

[9]

ENSURE system is configured in accordance with Appendix D, Switch Lineup.

[10]

ENSURE system is configured in accordance with Appendix E, Power Lineup.

[11]

ENSURE the Reactor Vessel Head is in place with the CRDM Shroud & Duct installed.

[12]

VERIFY the Reactor Coolant System (RCS) is NOT filled and vented.

A.

Section 6.4 B.

Section 6.5

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 25 of 164 Data Package: Page ____ of ____

Date ________

4.3 Field Preparations (continued)

NOTE The following jumpers will be used to simulate Phase B Containment Isolation Signals.

[13]

INSTALL switched jumpers at the following locations, AND ENSURE that the jumper test switches are OPEN (OFF).

[13.1]

Labeled TS-1:

In SSPS Train-A Output Cabinet 2-R-48, at TB615, between Pt. 11 (wire 2340VL) and Pt. 12 (wire CNA1).

(Drawing 45N2676-4).

A.

Jumper Installed 1st CV B.

Test Switch OPEN (OFF)

[13.2]

Labeled TS-2:

In SSPS Train-B Output Cabinet 2-R-51, at TB615, between Pt. 11 (wire 2435VL) and Pt. 12 (wire CNB1).

(Drawing 45N2677-4).

A.

Jumper Installed 1st CV B.

Test Switch OPEN (OFF)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 26 of 164 Data Package: Page ____ of ____

Date ________

4.3 Field Preparations (continued)

NOTE The following step will disable the CRDM Coolers Auto-start on Low Flow function.

[14]

LIFT the following wires:

A.

Wire A17BC3: Point 1 on Terminal Block TA in 2-JB-293-494 [Lwr Cntmt/703 AZ 50]

(Drawing 45W2748-1) 1st CV B.

Wire B17CC3: Point 2 on Terminal Block TA in 2-JB-293-517 [Lwr Cntmt/703 AZ 135]

(Drawing 45W2748-3) 1st CV C.

Wire A27AC3: Point 2 on Terminal Block TA in 2-JB-293-519 [Lwr Cntmt/703 AZ 221]

(Drawing 45W2748-2) 1st CV D.

Wire B27BC3: Point 2 on Terminal Block TA in 2-JB-293-521 [Lwr Cntmt/703 AZ 315]

(Drawing 45W2748-4) 1st CV

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 27 of 164 Data Package: Page ____ of ____

Date ________

4.4 Approvals and Notifications

[1]

OBTAIN permission of the Preoperational Startup Manager to start the test.

Preoperational Startup Manager Signature Date

[2]

OBTAIN the Unit 2 Supervisor's (US/SRO) or Shift Managers (SM) authorization.

Unit 2 US/SRO/SM Signature Date

[3]

OBTAIN the Unit 1 Supervisor's (US/SRO) or Shift Managers (SM) authorization.

Unit 1 US/SRO/SM Signature Date

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 28 of 164 Data Package: Page ____ of ____

Date ________

5.0 ACCEPTANCE CRITERIA A.

CRDM Cooler Dampers

1.

The CRDM Cooler Dampers manual controls and indications operate correctly.

Damper Controls and Indications (Main Control Room)

Controls and Indications (Auxiliary Control Room) 2-TCO-30-84 SubSection 6.1.1 SubSection 6.1.1 2-TCO-30-85 SubSection 6.1.2 SubSection 6.1.2 2-TCO-30-93 SubSection 6.1.3 SubSection 6.1.3 2-TCO-30-94 SubSection 6.1.4 SubSection 6.1.4 2-TCO-30-89 SubSection 6.1.5 SubSection 6.1.5 2-TCO-30-90 SubSection 6.1.6 SubSection 6.1.6 2-TCO-30-81 SubSection 6.1.7 SubSection 6.1.7 2-TCO-30-82 SubSection 6.1.8 SubSection 6.1.8

2.

The Shroud Suction Damper associated with each CRDM Cooler operates correctly Damper Opens/Closes when associated CRDM Cooler starts/stops XS in NOR XS in AUX 2-TCO-30-84 (CRDM Cooler 2A-A) 6.2.1[12]G 6.2.1[15]F 6.2.1[20]D 6.2.1[21]D 2-TCO-30-93 (CRDM Cooler 2B-B) 6.2.2[12]G 6.2.2[15]F 6.2.2[20]D 6.2.2[21]D 2-TCO-30-89 (CRDM Cooler 2C-A) 6.2.3[12]G 6.2.3[15]F 6.2.3[20]D 6.2.3[21]D 2-TCO-30-81 (CRDM Cooler 2D-B) 6.2.4[12]G 6.2.4[15]F 6.2.4[20]D 6.2.4[21]D

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 29 of 164 Data Package: Page ____ of ____

Date ________

5.0 ACCEPTANCE CRITERIA (continued)

B.

CRDM Cooler Units

1.

The CRDM Coolers manual and automatic controls, interlocks, annunciations, alarms, and indications operate correctly.

Cooler Controls and Indications (Main Control Room)

Controls and Indications (480V Shutdown Bds)

CRDM Cooler 2A-A (2-CLR-30-83)

SubSection 6.2.1 SubSection 6.2.1 CRDM Cooler 2B-B (2-CLR-30-92)

SubSection 6.2.2 SubSection 6.2.2 CRDM Cooler 2C-A (2-CLR-30-88)

SubSection 6.2.3 SubSection 6.2.3 CRDM Cooler 2D-B (2-CLR-30-80)

SubSection 6.2.4 SubSection 6.2.4

2.

CRDM Cooler intake and exhaust air temperatures output to the ICS properly.

ICS Points ICS Point Qualities are GOOD CRDM Cooler 2A-A:

T1100A T1105A 6.2.1[13]

CRDM Cooler 2B-B:

T1101A T1104A 6.2.2[13]

CRDM Cooler 2C-A:

T1102A T1104A 6.2.3[13]

CRDM Cooler 2D-B:

T1103A T1105A 6.2.4[13]

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 30 of 164 Data Package: Page ____ of ____

Date ________

5.0 ACCEPTANCE CRITERIA (continued)

3.

The ERCW Control Valves associated with each CRDM Cooler operate correctly.

Valve Valve modulates open/closes when CRDM Cooler starts/stops XS in NOR XS in AUX 2-TCV-67-85 (CRDM Cooler 2A-A) 6.2.1[12]G 6.2.1[15]F 6.2.1[20]D 6.2.1[21]D 2-TCV-67-101 (CRDM Cooler 2B-B) 6.2.2[12]G 6.2.2[15]F 6.2.2[20]D 6.2.2[21]D 2-TCV-67-93 (CRDM Cooler 2C-A) 6.2.3[12]G 6.2.3[15]F 6.2.3[20]D 6.2.3[21]D 2-TCV-67-109 (CRDM Cooler 2D-B) 6.2.4[12]G 6.2.4[15]F 6.2.4[20]D 6.2.4[21]D

4.

The CRDM Coolers respond appropriately to Engineered Safety Feature Actuation System (ESFAS) signals:

Cooler Phase B (B) Containment Isolation Signal XS in NORMAL XS in AUX Stops on B Remains stopped after B reset Can be manually started and run with B signal in effect CRDM Cooler 2A-A (2-CLR-30-83) 6.3.1[7]A 6.3.1[9]A 6.3.1[13]

CRDM Cooler 2B-B (2-CLR-30-92) 6.3.2[7]A 6.3.2[9]A 6.3.2[13]

CRDM Cooler 2C-A (2-CLR-30-88) 6.3.1[7]B 6.3.1[9]B 6.3.1[15]

CRDM Cooler 2D-B (2-CLR-30-80) 6.3.2[7]B 6.3.2[9]B 6.3.2[15]

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 31 of 164 Data Package: Page ____ of ____

Date ________

5.0 ACCEPTANCE CRITERIA (continued)

5.

The CRDM Coolers respond appropriately to a Bus Undervoltage condition.

Cooler XS in NORMAL XS in AUX Stops on LOOP Remains stopped after bus voltage is restored Stops on LOOP Restarts after bus voltage is restored CRDM Cooler 2A-A (2-CLR-30-83) 6.4.1[6]

6.4.1[8]

6.4.1[12]

6.4.1[14]

CRDM Cooler 2B-B (2-CLR-30-92) 6.4.2[6]

6.4.2[8]

6.4.2[12]

6.4.2[14]

CRDM Cooler 2C-A (2-CLR-30-88) 6.4.3[6]

6.4.3[8]

6.4.3[12]

6.4.3[14]

CRDM Cooler 2D-B (2-CLR-30-80) 6.4.4[6]

6.4.4[8]

6.4.4[12]

6.4.4[14]

6.

The CRDM Coolers respond appropriately to a Low Flow condition in their paired CRDM cooler. (Only when XS is in AUX)

Cooler Pair Auto-start on Low Flow in paired Cooler to maintain 1 Cooler per pair in operation.

CRDM Cooler 2A-A and 2D-B (2-CLR-30-83 and -80) 2A-A auto-start:

6.5.1[8]

2D-B auto-start:

6.5.1[11]

CRDM Cooler 2B-B and 2C-A (2-CLR-30-92 and -88) 2B-B auto-start:

6.5.2[8]

2C-A auto-start; 6.5.2[11]

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 32 of 164 Data Package: Page ____ of ____

Date ________

5.0 ACCEPTANCE CRITERIA (continued)

7.

The CRDM Coolers provide the required minimum air flows with suction aligned to the CRDM Shroud:

Cooler Minimum Flow per cooler: 21,500 CFM*

CRDM Cooler 2A-A (2-CLR-30-83) 6.6[4]

CRDM Cooler 2B-B (2-CLR-30-92) 6.6[5]

CRDM Cooler 2C-A (2-CLR-30-88) 6.6[6]

CRDM Cooler 2D-B (2-CLR-30-80) 6.6[7]

  • This instruction does not perform any air flow measurements. These are done in GTM-05, HVAC Air Balance. The uncertainties associated with taking these measurements will be handled within GTM-05 and will not be calculated in this instruction.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 33 of 164 Data Package: Page ____ of ____

Date ________

6.0 PERFORMANCE NOTES

1)

The Sections of this test shall be performed per the flow chart below:

2)

The Subsections of Sections 6.1 through 6.4 may be performed in any order provided that each Subsections applicable predecessor Subsection(s) are completed.

Section 6.5 is to be performed last and Section 6.6 may be performed at any time during this instruction. Unless otherwise noted, steps within each section are to be performed in the order written. The flowchart above may be used as a placekeeping tool throughout the performance of this instruction.

3)

CRDM Cooler Handswitches in the Main Control Room spring return to A AUTO from START and STOP positions.

4)

CRDM Cooler Handswitches on the 480V Shutdown Boards spring return to AUTO from CLOSE and TRIP positions.

5)

CRDM Coolers have status indication lights at two locations in the Main Control Room:



On 2-M-9 at their associated Handswitch



On 2-M-6, on Train A (2-XX-55-6E) or Train B (2-XX-55-6F) CONTAINMENT ISOL STATUS PNL, hereafter abbreviated in this instruction as CISP.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 34 of 164 Data Package: Page ____ of ____

Date ________

6.1 CRDM Cooler Dampers Logic Test NOTE Subsections 6.1.1 through 6.1.8 may be performed in any order. The diagram at the beginning of Section 6.0 may be used as a placekeeping tool throughout the performance of this Section. Unless otherwise noted, the steps within each Subsection shall be performed in the order written.

6.1.1 2-TCO-30-84, CRDM Cooler 2A-A Shroud Suction

[1]

ENSURE all prerequisites listed in Section 4.0 for Subsection 6.1 have been completed.

[2]

ENSURE Handswitch 2-HS-30-84A, CRDM CLR A-A SHROUD SUCT, [2-M-9], is in CLOSE.

[3]

ENSURE Transfer Switch 2-XS-30-84, CRDM CLR A-A SHROUD SUCT DMPR, [2-L-11A], is in NOR.

[4]

VERIFY on 2-HS-30-84C, CRDM CLR A-A SHROUD SUCTION, [2-L-10]:



Green Light OFF



Red Light OFF

[5]

PLACE Handswitch 2-HS-30-84A, CRDM CLR A-A SHROUD SUCT, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-84A:



Green Light OFF



Red Light ON B.

2-TCO-30-84, CRDM COOLER 2A-A SHROUD SUCTION, [Lwr Cntmt/703 AZ 15], is OPEN. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 35 of 164 Data Package: Page ____ of ____

Date ________

6.1.1 2-TCO-30-84, CRDM Cooler 2A-A Shroud Suction (continued)

[6]

PLACE Handswitch 2-HS-30-84A, CRDM CLR A-A SHROUD SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-84A:



Green Light ON



Red Light OFF B.

2-TCO-30-84, CRDM COOLER 2A-A SHROUD SUCTION, is CLOSED. (locally)

[7]

ENSURE Handswitch 2-HS-30-84C, CRDM CLR A-A SHROUD SUCTION, is in CLOSE.

[8]

ENSURE 2-XA-55-6F-148B, ACR PNL 2-L-11A, is CLEAR.

[9]

PLACE Transfer Switch 2-XS-30-84, CRDM CLR A-A SHROUD SUCT DMPR, to AUX, AND VERIFY the following:

A.

2-XA-55-6F-148B, ACR PNL 2-L-11A, is in ALARM.

B.

Unit 2 Alarm Events Display Screen indicates 148-B ACR PNL 2-L-11A XS IN AUX, is in ALARM (Red).

C.

On 2-HS-30-84A, CRDM CLR A-A SHROUD SUCT:



Green Light OFF



Red Light OFF D.

On Handswitch 2-HS-30-84C, CRDM CLR A-A SHROUD SUCTION:



Green Light ON



Red Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 36 of 164 Data Package: Page ____ of ____

Date ________

6.1.1 2-TCO-30-84, CRDM Cooler 2A-A Shroud Suction (continued)

[10]

PLACE Handswitch 2-HS-30-84C, CRDM CLR A-A SHROUD SUCTION, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-84C:



Green Light OFF



Red Light ON B.

2-TCO-30-84, CRDM COOLER 2A-A SHROUD SUCTION, is OPEN. (locally)

[11]

PLACE Handswitch 2-HS-30-84C, CRDM CLR A-A SHROUD SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-84C:



Green Light ON



Red Light OFF B.

2-TCO-30-84, CRDM COOLER 2A-A SHROUD SUCTION, is CLOSED. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 37 of 164 Data Package: Page ____ of ____

Date ________

6.1.1 2-TCO-30-84, CRDM Cooler 2A-A Shroud Suction (continued)

[12]

PLACE Transfer Switch 2-XS-30-84, CRDM CLR A-A SHROUD SUCT DMPR, to NOR, AND VERIFY the following:

A.

2-XA-55-6F-148B, ACR PNL 2-L-11A, is CLEAR.

B.

Unit 2 Alarm Events Display Screen indicates 148-B ACR PNL 2-L-11A XS IN AUX, is NORMAL (Green).

C.

On 2-HS-30-84A, CRDM CLR A-A SHROUD SUCT:



Green Light ON



Red Light OFF D.

On Handswitch 2-HS-30-84C, CRDM CLR A-A SHROUD SUCTION:



Green Light OFF



Red Light OFF

[13]

VERIFY successful completion of this Subsection 6.1.1.

(Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 38 of 164 Data Package: Page ____ of ____

Date ________

6.1.2 2-TCO-30-85, CRDM Cooler 2A-A Lower Containment Suction

[1]

ENSURE all prerequisites listed in Section 4.0 for Subsection 6.1 have been completed.

[2]

ENSURE Handswitch 2-HS-30-85A, CRDM CLR A-A LWR CNTMT SUCT, [2-M-9], is in OPEN.

[3]

ENSURE Transfer Switch 2-XS-30-85, CRDM CLR A-A LWR CNTMT SUCT DMPR, [2-L-11A], is in NOR.

[4]

VERIFY on 2-HS-30-85C, CRDM CLR A-A LWR CNTMT SUCT, [2-L-10]:



Green Light OFF



Red Light OFF

[5]

PLACE Handswitch 2-HS-30-85A, CRDM CLR A-A LWR CNTMT SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-85A:



Green Light ON



Red Light OFF B.

2-TCO-30-85, CRDM COOLER 2A-A LOWER COMPARTMENT SUCT, [Lwr Cntmt/703 AZ 15],

is CLOSED. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 39 of 164 Data Package: Page ____ of ____

Date ________

6.1.2 2-TCO-30-85, CRDM Cooler 2A-A Lower Containment Suction (continued)

[6]

PLACE Handswitch 2-HS-30-85A, CRDM CLR A-A LWR CNTMT SUCT, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-85A:



Green Light OFF



Red Light ON B.

2-TCO-30-85, CRDM COOLER 2A-A LOWER COMPARTMENT SUCT, is OPEN. (locally)

[7]

ENSURE Handswitch 2-HS-30-85C, CRDM CLR A-A LWR CNTMT SUCT, is in OPEN.

[8]

ENSURE 2-XA-55-6F-148B, ACR PNL 2-L-11A, is CLEAR.

[9]

PLACE Transfer Switch 2-XS-30-85, CRDM CLR A-A LWR CNTMT SUCT DMPR, to AUX, AND VERIFY the following:

A.

2-XA-55-6F-148B, ACR PNL 2-L-11A, is in ALARM.

B.

Unit 2 Alarm Events Display Screen indicates 148-B ACR PNL 2-L-11A XS IN AUX, is in ALARM (Red).

C.

On 2-HS-30-85A, CRDM CLR A-A LWR CNTMT SUCT:



Green Light OFF



Red Light OFF D.

On Handswitch 2-HS-30-85C, CRDM CLR A-A LWR CNTMT SUCT:



Green Light OFF



Red Light ON

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 40 of 164 Data Package: Page ____ of ____

Date ________

6.1.2 2-TCO-30-85, CRDM Cooler 2A-A Lower Containment Suction (continued)

[10]

PLACE Handswitch 2-HS-30-85C, CRDM CLR A-A LWR CNTMT SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-85C:



Green Light ON



Red Light OFF B.

2-TCO-30-85, CRDM COOLER 2A-A LOWER COMPARTMENT SUCT, is CLOSED. (locally)

[11]

PLACE Handswitch 2-HS-30-85C, CRDM CLR A-A LWR CNTMT SUCT, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-85C:



Green Light OFF



Red Light ON B.

2-TCO-30-85, CRDM COOLER 2A-A LOWER COMPARTMENT SUCT, is OPEN. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 41 of 164 Data Package: Page ____ of ____

Date ________

6.1.2 2-TCO-30-85, CRDM Cooler 2A-A Lower Containment Suction (continued)

[12]

PLACE Transfer Switch 2-XS-30-85, CRDM CLR A-A LWR CNTMT SUCT DMPR, to NOR, AND VERIFY the following:

A.

2-XA-55-6F-148B, ACR PNL 2-L-11A, is CLEAR.

B.

Unit 2 Alarm Events Display Screen indicates 148-B ACR PNL 2-L-11A XS IN AUX, is NORMAL (Green).

C.

On 2-HS-30-85A, CRDM CLR A-A LWR CNTMT SUCT:



Green Light OFF



Red Light ON D.

On Handswitch 2-HS-30-85C, CRDM CLR A-A LWR CNTMT SUCT:



Green Light OFF



Red Light OFF

[13]

VERIFY successful completion of this Subsection 6.1.2.

(Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 42 of 164 Data Package: Page ____ of ____

Date ________

6.1.3 2-TCO-30-93, CRDM Cooler 2B-B Shroud Suction

[1]

ENSURE all prerequisites listed in Section 4.0 for Subsection 6.1 have been completed.

[2]

ENSURE Handswitch 2-HS-30-93A, CRDM CLR B-B SHROUD SUCT, [2-M-9], is in CLOSE.

[3]

ENSURE Transfer Switch 2-XS-30-93, CRDM CLR B-B SHROUD SUCT DMPR, [2-L-11B], is in NOR.

[4]

VERIFY on 2-HS-30-93C, CRDM CLR B-B SHROUD SUCTION, [2-L-10]:



Green Light OFF



Red Light OFF

[5]

PLACE Handswitch 2-HS-30-93A, CRDM CLR B-B SHROUD SUCT, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-93A:



Green Light OFF



Red Light ON B.

2-TCO-30-93, CRDM COOLER 2B-B SHROUD SUCTION, [Lwr Cntmt/703 AZ 165], is OPEN. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 43 of 164 Data Package: Page ____ of ____

Date ________

6.1.3 2-TCO-30-93, CRDM Cooler 2B-B Shroud Suction (continued)

[6]

PLACE Handswitch 2-HS-30-93A, CRDM CLR B-B SHROUD SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-93A:



Green Light ON



Red Light OFF B.

2-TCO-30-93, CRDM COOLER 2B-B SHROUD SUCTION, is CLOSED. (locally)

[7]

ENSURE Handswitch 2-HS-30-93C, CRDM CLR B-B SHROUD SUCTION, is in CLOSE.

[8]

ENSURE 2-XA-55-6F-148C, ACR PNL 2-L-11B, is CLEAR.

[9]

PLACE Transfer Switch 2-XS-30-93, CRDM CLR B-B SHROUD SUCT DMPR, to AUX, AND VERIFY the following:

A.

2-XA-55-6F-148C, ACR PNL 2-L-11B, is in ALARM.

B.

Unit 2 Alarm Events Display Screen indicates 148-C ACR PNL 2-L-11B XS IN AUX, is in ALARM (Red).

C.

On 2-HS-30-93A, CRDM CLR B-B SHROUD SUCT:



Green Light OFF



Red Light OFF D.

On Handswitch 2-HS-30-93C, CRDM CLR B-B SHROUD SUCTION:



Green Light ON



Red Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 44 of 164 Data Package: Page ____ of ____

Date ________

6.1.3 2-TCO-30-93, CRDM Cooler 2B-B Shroud Suction (continued)

[10]

PLACE Handswitch 2-HS-30-93C, CRDM CLR B-B SHROUD SUCTION, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-93C:



Green Light OFF



Red Light ON B.

2-TCO-30-93, CRDM COOLER 2B-B SHROUD SUCTION, is OPEN. (locally)

[11]

PLACE Handswitch 2-HS-30-93C, CRDM CLR B-B SHROUD SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-93C:



Green Light ON



Red Light OFF B.

2-TCO-30-93, CRDM COOLER 2B-B SHROUD SUCTION, is CLOSED. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 45 of 164 Data Package: Page ____ of ____

Date ________

6.1.3 2-TCO-30-93, CRDM Cooler 2B-B Shroud Suction (continued)

[12]

PLACE Transfer Switch 2-XS-30-93, CRDM CLR B-B SHROUD SUCT DMPR, to NOR, AND VERIFY the following:

A.

2-XA-55-6F-148C, ACR PNL 2-L-11B, is CLEAR.

B.

Unit 2 Alarm Events Display Screen indicates 148-C ACR PNL 2-L-11B XS IN AUX, is NORMAL (Green).

C.

On 2-HS-30-93A, CRDM CLR B-B SHROUD SUCT:



Green Light ON



Red Light OFF D.

On Handswitch 2-HS-30-93C, CRDM CLR B-B SHROUD SUCTION:



Green Light OFF



Red Light OFF

[13]

VERIFY successful completion of this Subsection 6.1.3.

(Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 46 of 164 Data Package: Page ____ of ____

Date ________

6.1.4 2-TCO-30-94, CRDM Cooler 2B-B Lower Containment Suction

[1]

ENSURE all prerequisites listed in Section 4.0 for Subsection 6.1 have been completed.

[2]

ENSURE Handswitch 2-HS-30-94A, CRDM CLR B-B LWR CNTMT SUCT, [2-M-9], is in OPEN.

[3]

ENSURE Transfer Switch 2-XS-30-94, CRDM CLR B-B LWR CNTMT SUCT DMPR, [2-L-11B], is in NOR.

[4]

VERIFY on 2-HS-30-94C, CRDM CLR B-B LWR CNTMT SUCT, [2-L-10]:



Green Light OFF



Red Light OFF

[5]

PLACE Handswitch 2-HS-30-94A, CRDM CLR B-B LWR CNTMT SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-94A:



Green Light ON



Red Light OFF B.

2-TCO-30-94, CRDM COOLER 2B-B LOWER COMPARTMENT SUCT, [Lwr Cntmt/703 AZ 165],

is CLOSED. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 47 of 164 Data Package: Page ____ of ____

Date ________

6.1.4 2-TCO-30-94, CRDM Cooler 2B-B Lower Containment Suction (continued)

[6]

PLACE Handswitch 2-HS-30-94A, CRDM CLR B-B LWR CNTMT SUCT, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-94A:



Green Light OFF



Red Light ON B.

2-TCO-30-94, CRDM COOLER 2B-B LOWER COMPARTMENT SUCT, is OPEN. (locally)

[7]

ENSURE Handswitch 2-HS-30-94C, CRDM CLR B-B LWR CNTMT SUCT, is in OPEN.

[8]

ENSURE 2-XA-55-6F-148C, ACR PNL 2-L-11B, is CLEAR.

[9]

PLACE Transfer Switch 2-XS-30-94, CRDM CLR B-B LWR CNTMT SUCT DMPR, to AUX, AND VERIFY the following:

A.

2-XA-55-6F-148C, ACR PNL 2-L-11B, is in ALARM.

B.

Unit 2 Alarm Events Display Screen indicates 148-C ACR PNL 2-L-11B XS IN AUX, is in ALARM (Red).

C.

On 2-HS-30-94A, CRDM CLR B-B LWR CNTMT SUCT:



Green Light OFF



Red Light OFF D.

On Handswitch 2-HS-30-94C, CRDM CLR B-B LWR CNTMT SUCT:



Green Light OFF



Red Light ON

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 48 of 164 Data Package: Page ____ of ____

Date ________

6.1.4 2-TCO-30-94, CRDM Cooler 2B-B Lower Containment Suction (continued)

[10]

PLACE Handswitch 2-HS-30-94C, CRDM CLR B-B LWR CNTMT SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-94C:



Green Light ON



Red Light OFF B.

2-TCO-30-94, CRDM COOLER 2B-B LOWER COMPARTMENT SUCT, is CLOSED. (locally)

[11]

PLACE Handswitch 2-HS-30-94C, CRDM CLR B-B LWR CNTMT SUCT, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-94C:



Green Light OFF



Red Light ON B.

2-TCO-30-94, CRDM COOLER 2B-B LOWER COMPARTMENT SUCT, is OPEN. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 49 of 164 Data Package: Page ____ of ____

Date ________

6.1.4 2-TCO-30-94, CRDM Cooler 2B-B Lower Containment Suction (continued)

[12]

PLACE Transfer Switch 2-XS-30-94, CRDM CLR B-B LWR CNTMT SUCT DMPR, to NOR, AND VERIFY the following:

A.

2-XA-55-6F-148C, ACR PNL 2-L-11B, is CLEAR.

B.

Unit 2 Alarm Events Display Screen indicates 148-C ACR PNL 2-L-11B XS IN AUX, is NORMAL (Green).

C.

On 2-HS-30-94A, CRDM CLR B-B LWR CNTMT SUCT:



Green Light OFF



Red Light ON D.

On Handswitch 2-HS-30-94C, CRDM CLR B-B LWR CNTMT SUCT:



Green Light OFF



Red Light OFF

[13]

VERIFY successful completion of this Subsection 6.1.4.

(Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 50 of 164 Data Package: Page ____ of ____

Date ________

6.1.5 2-TCO-30-89, CRDM Cooler 2C-A Shroud Suction

[1]

ENSURE all prerequisites listed in Section 4.0 for Subsection 6.1 have been completed.

[2]

ENSURE Handswitch 2-HS-30-89A, CRDM CLR C-A SHROUD SUCT, [2-M-9], is in CLOSE.

[3]

ENSURE Transfer Switch 2-XS-30-89, CRDM CLR C-A SHROUD SUCT DMPR, [2-L-11A], is in NOR.

[4]

VERIFY on 2-HS-30-89C, CRDM CLR C-A SHROUD SUCTION, [2-L-10]:



Green Light OFF



Red Light OFF

[5]

PLACE Handswitch 2-HS-30-89A, CRDM CLR C-A SHROUD SUCT, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-89A:



Green Light OFF



Red Light ON B.

2-TCO-30-89, CRDM COOLER 2C-A SHROUD SUCTION, [Lwr Cntmt/703 AZ 195], is OPEN. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 51 of 164 Data Package: Page ____ of ____

Date ________

6.1.5 2-TCO-30-89, CRDM Cooler 2C-A Shroud Suction (continued)

[6]

PLACE Handswitch 2-HS-30-89A, CRDM CLR C-A SHROUD SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-89A:



Green Light ON



Red Light OFF B.

2-TCO-30-89, CRDM COOLER 2C-A SHROUD SUCTION, is CLOSED. (locally)

[7]

ENSURE Handswitch 2-HS-30-89C, CRDM CLR C-A SHROUD SUCTION, is in CLOSE.

[8]

ENSURE 2-XA-55-6F-148B, ACR PNL 2-L-11A, is CLEAR.

[9]

PLACE Transfer Switch 2-XS-30-89, CRDM CLR C-A SHROUD SUCT DMPR, to AUX, AND VERIFY the following:

A.

2-XA-55-6F-148B, ACR PNL 2-L-11A, is in ALARM.

B.

Unit 2 Alarm Events Display Screen indicates 148-B ACR PNL 2-L-11A XS IN AUX, is in ALARM (Red).

C.

On 2-HS-30-89A, CRDM CLR C-A SHROUD SUCT:



Green Light OFF



Red Light OFF D.

On Handswitch 2-HS-30-89C, CRDM CLR C-A SHROUD SUCTION:



Green Light ON



Red Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 52 of 164 Data Package: Page ____ of ____

Date ________

6.1.5 2-TCO-30-89, CRDM Cooler 2C-A Shroud Suction (continued)

[10]

PLACE Handswitch 2-HS-30-89C, CRDM CLR C-A SHROUD SUCTION, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-89C:



Green Light OFF



Red Light ON B.

2-TCO-30-89, CRDM COOLER 2C-A SHROUD SUCTION, is OPEN. (locally)

[11]

PLACE Handswitch 2-HS-30-89C, CRDM CLR C-A SHROUD SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-89C:



Green Light ON



Red Light OFF B.

2-TCO-30-89, CRDM COOLER 2C-A SHROUD SUCTION, is CLOSED. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 53 of 164 Data Package: Page ____ of ____

Date ________

6.1.5 2-TCO-30-89, CRDM Cooler 2C-A Shroud Suction (continued)

[12]

PLACE Transfer Switch 2-XS-30-89, CRDM CLR C-A SHROUD SUCT DMPR, to NOR, AND VERIFY the following:

A.

2-XA-55-6F-148B, ACR PNL 2-L-11A, is CLEAR.

B.

Unit 2 Alarm Events Display Screen indicates 148-B ACR PNL 2-L-11A XS IN AUX, is NORMAL (Green).

C.

On 2-HS-30-89A, CRDM CLR C-A SHROUD SUCT:



Green Light ON



Red Light OFF D.

On Handswitch 2-HS-30-89C, CRDM CLR C-A SHROUD SUCTION:



Green Light OFF



Red Light OFF

[13]

VERIFY successful completion of this Subsection 6.1.5.

(Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 54 of 164 Data Package: Page ____ of ____

Date ________

6.1.6 2-TCO-30-90, CRDM Cooler 2C-A Lower Containment Suction

[1]

ENSURE all prerequisites listed in Section 4.0 for Subsection 6.1 have been completed.

[2]

ENSURE Handswitch 2-HS-30-90A, CRDM CLR C-A LWR CNTMT SUCT, [2-M-9], is in OPEN.

[3]

ENSURE Transfer Switch 2-XS-30-90, CRDM CLR C-A LWR CNTMT SUCT DMPR, [2-L-11A], is in NOR.

[4]

VERIFY on 2-HS-30-90C, CRDM CLR C-A LWR CNTMT SUCT, [2-L-10]:



Green Light OFF



Red Light OFF

[5]

PLACE Handswitch 2-HS-30-90A, CRDM CLR C-A LWR CNTMT SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-90A:



Green Light ON



Red Light OFF B.

2-TCO-30-90, CRDM COOLER 2C-A LOWER COMPARTMENT SUCT, [Lwr Cntmt/703 AZ 195],

is CLOSED. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 55 of 164 Data Package: Page ____ of ____

Date ________

6.1.6 2-TCO-30-90, CRDM Cooler 2C-A Lower Containment Suction (continued)

[6]

PLACE Handswitch 2-HS-30-90A, CRDM CLR C-A LWR CNTMT SUCT, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-90A:



Green Light OFF



Red Light ON B.

2-TCO-30-90, CRDM COOLER 2C-A LOWER COMPARTMENT SUCT, is OPEN. (locally)

[7]

ENSURE Handswitch 2-HS-30-90C, CRDM CLR C-A LWR CNTMT SUCT, is in OPEN.

[8]

ENSURE 2-XA-55-6F-148B, ACR PNL 2-L-11A, is CLEAR.

[9]

PLACE Transfer Switch 2-XS-30-90, CRDM CLR C-A LWR CNTMT SUCT DMPR, to AUX, AND VERIFY the following:

A.

2-XA-55-6F-148B, ACR PNL 2-L-11A, is in ALARM.

B.

Unit 2 Alarm Events Display Screen indicates 148-B ACR PNL 2-L-11A XS IN AUX, is in ALARM (Red).

C.

On 2-HS-30-90A, CRDM CLR C-A LWR CNTMT SUCT:



Green Light OFF



Red Light OFF D.

On Handswitch 2-HS-30-90C, CRDM CLR C-A LWR CNTMT SUCT:



Green Light OFF



Red Light ON

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 56 of 164 Data Package: Page ____ of ____

Date ________

6.1.6 2-TCO-30-90, CRDM Cooler 2C-A Lower Containment Suction (continued)

[10]

PLACE Handswitch 2-HS-30-90C, CRDM CLR C-A LWR CNTMT SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-90C:



Green Light ON



Red Light OFF B.

2-TCO-30-90, CRDM COOLER 2C-A LOWER COMPARTMENT SUCT, is CLOSED. (locally)

[11]

PLACE Handswitch 2-HS-30-90C, CRDM CLR C-A LWR CNTMT SUCT, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-90C:



Green Light OFF



Red Light ON B.

2-TCO-30-90, CRDM COOLER 2C-A LOWER COMPARTMENT SUCT, is OPEN. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 57 of 164 Data Package: Page ____ of ____

Date ________

6.1.6 2-TCO-30-90, CRDM Cooler 2C-A Lower Containment Suction (continued)

[12]

PLACE Transfer Switch 2-XS-30-90, CRDM CLR C-A LWR CNTMT SUCT DMPR, to NOR, AND VERIFY the following:

A.

2-XA-55-6F-148B, ACR PNL 2-L-11A, is CLEAR.

B.

Unit 2 Alarm Events Display Screen indicates 148-B ACR PNL 2-L-11A XS IN AUX, is NORMAL (Green).

C.

On 2-HS-30-90A, CRDM CLR C-A LWR CNTMT SUCT:



Green Light OFF



Red Light ON D.

On Handswitch 2-HS-30-90C, CRDM CLR C-A LWR CNTMT SUCT:



Green Light OFF



Red Light OFF

[13]

VERIFY successful completion of this Subsection 6.1.6.

(Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 58 of 164 Data Package: Page ____ of ____

Date ________

6.1.7 2-TCO-30-81, CRDM Cooler 2D-B Shroud Suction

[1]

ENSURE all prerequisites listed in Section 4.0 for Subsection 6.1 have been completed.

[2]

ENSURE Handswitch 2-HS-30-81A, CRDM CLR D-B SHROUD SUCT, [2-M-9], is in CLOSE.

[3]

ENSURE Transfer Switch 2-XS-30-81, CRDM CLR D-B SHROUD SUCT DMPR, [2-L-11B], is in NOR.

[4]

VERIFY on 2-HS-30-81C, CRDM CLR D-B SHROUD SUCTION, [2-L-10]:



Green Light OFF



Red Light OFF

[5]

PLACE Handswitch 2-HS-30-81A, CRDM CLR D-B SHROUD SUCT, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-81A:



Green Light OFF



Red Light ON B.

2-TCO-30-81, CRDM COOLER 2D-B SHROUD SUCTION, [Lwr Cntmt/703 AZ 345], is OPEN. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 59 of 164 Data Package: Page ____ of ____

Date ________

6.1.7 2-TCO-30-81, CRDM Cooler 2D-B Shroud Suction (continued)

[6]

PLACE Handswitch 2-HS-30-81A, CRDM CLR D-B SHROUD SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-81A:



Green Light ON



Red Light OFF B.

2-TCO-30-81, CRDM COOLER 2D-B SHROUD SUCTION, is CLOSED. (locally)

[7]

ENSURE Handswitch 2-HS-30-81C, CRDM CLR D-B SHROUD SUCTION, is in CLOSE.

[8]

ENSURE 2-XA-55-6F-148C, ACR PNL 2-L-11B, is CLEAR.

[9]

PLACE Transfer Switch 2-XS-30-81, CRDM CLR D-B SHROUD SUCT DMPR, to AUX, AND VERIFY the following:

A.

2-XA-55-6F-148C, ACR PNL 2-L-11B, is in ALARM.

B.

Unit 2 Alarm Events Display Screen indicates 148-C ACR PNL 2-L-11B XS IN AUX, is in ALARM (Red).

C.

On 2-HS-30-81A, CRDM CLR D-B SHROUD SUCT:



Green Light OFF



Red Light OFF D.

On Handswitch 2-HS-30-81C, CRDM CLR D-B SHROUD SUCTION:



Green Light ON



Red Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 60 of 164 Data Package: Page ____ of ____

Date ________

6.1.7 2-TCO-30-81, CRDM Cooler 2D-B Shroud Suction (continued)

[10]

PLACE Handswitch 2-HS-30-81C, CRDM CLR D-B SHROUD SUCTION, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-81C:



Green Light OFF



Red Light ON B.

2-TCO-30-81, CRDM COOLER 2D-B SHROUD SUCTION, is OPEN. (locally)

[11]

PLACE Handswitch 2-HS-30-81C, CRDM CLR D-B SHROUD SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-81C:



Green Light ON



Red Light OFF B.

2-TCO-30-81, CRDM COOLER 2D-B SHROUD SUCTION, is CLOSED. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 61 of 164 Data Package: Page ____ of ____

Date ________

6.1.7 2-TCO-30-81, CRDM Cooler 2D-B Shroud Suction (continued)

[12]

PLACE Transfer Switch 2-XS-30-81, CRDM CLR D-B SHROUD SUCT DMPR, to NOR, AND VERIFY the following:

A.

2-XA-55-6F-148C, ACR PNL 2-L-11B, is CLEAR.

B.

Unit 2 Alarm Events Display Screen indicates 148-C ACR PNL 2-L-11B XS IN AUX, is NORMAL (Green).

C.

On 2-HS-30-81A, CRDM CLR D-B SHROUD SUCT:



Green Light ON



Red Light OFF D.

On Handswitch 2-HS-30-81C, CRDM CLR D-B SHROUD SUCTION:



Green Light OFF



Red Light OFF

[13]

VERIFY successful completion of this Subsection 6.1.7.

(Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 62 of 164 Data Package: Page ____ of ____

Date ________

6.1.8 2-TCO-30-82, CRDM Cooler 2D-B Lower Containment Suction

[1]

ENSURE all prerequisites listed in Section 4.0 for Subsection 6.1 have been completed.

[2]

ENSURE Handswitch 2-HS-30-82A, CRDM CLR D-B LWR CNTMT SUCT, [2-M-9], is in OPEN.

[3]

ENSURE Transfer Switch 2-XS-30-82, CRDM CLR D-B LWR CNTMT SUCT DMPR, [2-L-11B], is in NOR.

[4]

VERIFY on 2-HS-30-82C, CRDM CLR D-B LWR CNTMT SUCT, [2-L-10]:



Green Light OFF



Red Light OFF

[5]

PLACE Handswitch 2-HS-30-82A, CRDM CLR D-B LWR CNTMT SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-82A:



Green Light ON



Red Light OFF B.

2-TCO-30-82, CRDM COOLER 2D-B LOWER COMPARTMENT SUCT, [Lwr Cntmt/703 AZ 345],

is CLOSED. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 63 of 164 Data Package: Page ____ of ____

Date ________

6.1.8 2-TCO-30-82, CRDM Cooler 2D-B Lower Containment Suction (continued)

[6]

PLACE Handswitch 2-HS-30-82A, CRDM CLR D-B LWR CNTMT SUCT, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-82A:



Green Light OFF



Red Light ON B.

2-TCO-30-82, CRDM COOLER 2D-B LOWER COMPARTMENT SUCT, is OPEN. (locally)

[7]

ENSURE Handswitch 2-HS-30-82C, CRDM CLR D-B LWR CNTMT SUCT, is in OPEN.

[8]

ENSURE 2-XA-55-6F-148C, ACR PNL 2-L-11B, is CLEAR.

[9]

PLACE Transfer Switch 2-XS-30-82, CRDM CLR D-B LWR CNTMT SUCT DMPR, to AUX, AND VERIFY the following:

A.

2-XA-55-6F-148C, ACR PNL 2-L-11B, is in ALARM.

B.

Unit 2 Alarm Events Display Screen indicates 148-C ACR PNL 2-L-11B XS IN AUX, is in ALARM (Red).

C.

On 2-HS-30-82A, CRDM CLR D-B LWR CNTMT SUCT:



Green Light OFF



Red Light OFF D.

On Handswitch 2-HS-30-82C, CRDM CLR D-B LWR CNTMT SUCT:



Green Light OFF



Red Light ON

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 64 of 164 Data Package: Page ____ of ____

Date ________

6.1.8 2-TCO-30-82, CRDM Cooler 2D-B Lower Containment Suction (continued)

[10]

PLACE Handswitch 2-HS-30-82C, CRDM CLR D-B LWR CNTMT SUCT, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-82C:



Green Light ON



Red Light OFF B.

2-TCO-30-82, CRDM COOLER 2D-B LOWER COMPARTMENT SUCT, is CLOSED. (locally)

[11]

PLACE Handswitch 2-HS-30-82C, CRDM CLR D-B LWR CNTMT SUCT, to OPEN, AND VERIFY the following:

A.

On Handswitch 2-HS-30-82C:



Green Light OFF



Red Light ON B.

2-TCO-30-82, CRDM COOLER 2D-B LOWER COMPARTMENT SUCT, is OPEN. (locally)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 65 of 164 Data Package: Page ____ of ____

Date ________

6.1.8 2-TCO-30-82, CRDM Cooler 2D-B Lower Containment Suction (continued)

[12]

PLACE Transfer Switch 2-XS-30-82, CRDM CLR D-B LWR CNTMT SUCT DMPR, to NOR, AND VERIFY the following:

A.

2-XA-55-6F-148C, ACR PNL 2-L-11B, is CLEAR.

B.

Unit 2 Alarm Events Display Screen indicates 148-C ACR PNL 2-L-11B XS IN AUX, is NORMAL (Green).

C.

On 2-HS-30-82A, CRDM CLR D-B LWR CNTMT SUCT:



Green Light OFF



Red Light ON D.

On Handswitch 2-HS-30-82C, CRDM CLR D-B LWR CNTMT SUCT:



Green Light OFF



Red Light OFF

[13]

VERIFY successful completion of this Subsection 6.1.8.

(Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 66 of 164 Data Package: Page ____ of ____

Date ________

6.2 CRDM Cooler Logic Test NOTE Subsections 6.2.1 through 6.2.4 may be performed in any order, provided their applicable predecessor Subsections are completed. Unless otherwise noted, the steps within each Subsection shall be performed in the order written. The diagram at the beginning of Section 6.0 may be used as a placekeeping tool throughout the performance of this Section.

6.2.1 CRDM Cooler 2A-A Logic NOTE Subsection 6.2.1 will be starting a stopping CRDM Cooler 2A-A. Ensure personnel and loose equipment are clear of fan discharge and that personnel in the area are cognizant of expected fan start prior to starting a CRDM Cooler.

[1]

ENSURE all prerequisites listed in Section 4.0 for Section 6.2 and Subsection 6.2.1 have been completed.

[2]

ENSURE Subsections 6.1.1 and 6.1.2 have been completed.

[3]

RACK Breaker 2-BKR-30-83, CRDM CLR 2A-A (2-CLR-30-83), [480V SHUTDOWN BOARD 2A1-A, Compartment 7B], to the TEST position.

[4]

VERIFY 2-XA-55-5C-102A, CRDM COOLER FLOW LO, is CLEAR.

[5]

PRESS the CRDM CLR FAN 2A-A MTR 1 BKR TEST CLOSE switch at Breaker 2-BKR-30-83, CRDM CLR 2A-A (2-CLR-30-83), AND VERIFY the following:

A.

At Breaker 2-BKR-30-83:



Green Light OFF



Red Light ON



Red Flag at Breaker Panel

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 67 of 164 Data Package: Page ____ of ____

Date ________

6.2.1 CRDM Cooler 2A-A Logic (continued)

B.

2-XA-55-5C-102A, CRDM COOLER FLOW LO, is in ALARM (after approximately 30 seconds).

C.

Unit 2 Alarm Events Display Screen indicates 102-A CRDM COOLER A-A AIR FLOW LO, is in ALARM (Red).

[6]

PRESS the CRDM CLR FAN 2A-A MTR 1 BKR TEST TRIP switch at Breaker 2-BKR-30-83, CRDM CLR 2A-A (2-CLR-30-83), AND VERIFY the following:

A.

At Breaker 2-BKR-30-83:



Green Light ON



Red Light OFF



Green Flag at Breaker Panel B.

2-XA-55-5C-102A, CRDM COOLER FLOW LO, is CLEAR.

C.

Unit 2 Alarm Events Display Screen indicates 102-A CRDM COOLER A-A AIR FLOW LO, is NORMAL (Green).

[7]

ENSURE Transfer Switch 2-XS-30-83, CRDM CLR 2A-A FAN 1 & 2, [480V SHUTDOWN BOARD 2A1-A, Compartment 5A], is in NORMAL.

[8]

RACK Breaker 2-BKR-30-83, CRDM CLR 2A-A (2-CLR-30-83), to the CONNECTED position.

[9]

PLACE Handswitch 2-HS-30-84A, CRDM CLR A-A SHROUD SUCT, [2-M-9], to P AUTO.

[10]

PLACE Handswitch 2-HS-30-85A, CRDM CLR A-A LWR CNTMT SUCT, [2-M-9], to CLOSE.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 68 of 164 Data Package: Page ____ of ____

Date ________

6.2.1 CRDM Cooler 2A-A Logic (continued)

[11]

VERIFY the following:

A.

Cooler 2-CLR-30-83, CRDM COOLER 2A-A,

[Lwr Cntmt/703 AZ 25], is OFF.

B.

Damper 2-TCO-30-84, CRDM COOLER 2A-A SHROUD SUCTION, [Lwr Cntmt/703 AZ 15], is CLOSED.

C.

2-XA-55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is CLEAR

[12]

PLACE Handswitch 2-HS-30-83A, CRDM CLR A-A, [2-M-9],

to START, AND VERIFY the following:

A.

On Handswitch 2-HS-30-83A:



Green Light OFF



Red Light ON



White Light OFF B.

On Handswitch 2-HS-30-84A, CRDM CLR A-A SHROUD SUCT:



Green Light OFF



Red Light ON C.

On 2-XX-55-6E, Train A CISP, Window 105, CRDM CLR A FAN-30-83, [2-M-6]:



Green Light OFF



Red Light ON D.

2-XA-55-5C-102A, CRDM COOLER FLOW LO, remains CLEAR. (after approximately 30 seconds)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 69 of 164 Data Package: Page ____ of ____

Date ________

6.2.1 CRDM Cooler 2A-A Logic (continued)

E.

On Handswitch 2-HS-30-83C, CRDM CLR 2A-A FAN 1 & 2, [480V SHUTDOWN BOARD 2A1-A, Compartment 5A]:



Green Light OFF



Red Light ON F.

At Breaker 2-BKR-30-83, CRDM CLR 2A-A (2-CLR-30-83):



Green Light OFF



Red Light ON G. Locally:



Cooler 2-CLR-30-83, CRDM COOLER 2A-A, is ON.



Damper 2-TCO-30-84, CRDM COOLER 2A-A SHROUD SUCTION, is OPEN. (Acc Crit)



Valve 2-TCV-67-85, CRD VENT CLR 2A-A OUT TEMP CNTL, [Lwr Cntmt/716 AZ 8 (S Fan Rm)],

modulates OPEN. (Acc Crit)

[13]

VERIFY that the CRDM Cooler 2A-A intake and exhaust air temperature ICS Point Qualities are GOOD (Green).

(Acc Crit)



T1105A, CRDM COOL UNIT A-A D-B INTAKE



T1100A, CRDM COOL UNIT A-A EXHAUST

[14]

RECORD CRDM Cooler 2A-A intake and exhaust air temperatures as indicated by the ICS log points:

T1105A, CRDM COOL UNIT A-A D-B INTAKE:

________________ F T1100A, CRDM COOL UNIT A-A EXHAUST:

________________ F

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 70 of 164 Data Package: Page ____ of ____

Date ________

6.2.1 CRDM Cooler 2A-A Logic (continued)

[15]

PLACE Handswitch 2-HS-30-83A, CRDM CLR A-A, to STOP, AND VERIFY the following:

A.

On Handswitch 2-HS-30-83A:



Green Light ON



Red Light OFF



White Light OFF B.

On Handswitch 2-HS-30-84A, CRDM CLR A-A SHROUD SUCT:



Green Light ON



Red Light OFF C.

On 2-XX-55-6E, Train A CISP, Window 105 CRDM CLR A FAN-30-83:



Green Light ON



Red Light OFF D.

On Handswitch 2-HS-30-83C, CRDM CLR 2A-A FAN 1 & 2:



Green Light ON



Red Light OFF E.

At Breaker 2-BKR-30-83, CRDM CLR 2A-A (2-CLR-30-83):



Green Light ON



Red Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 71 of 164 Data Package: Page ____ of ____

Date ________

6.2.1 CRDM Cooler 2A-A Logic (continued)

F.

Locally:



Cooler 2-CLR-30-83, CRDM COOLER 2A-A, is OFF.



Damper 2-TCO-30-84, CRDM COOLER 2A-A SHROUD SUCTION, is CLOSED. (Acc Crit)



Valve 2-TCV-67-85, CRD VENT CLR 2A-A OUT TEMP CNTL, is CLOSED. (Acc Crit)

[16]

ENSURE 2-XA-55-6F-149B, 480 SD BD 2A1-A/2A2-A/CA VT BD 2A1-A, is CLEAR.

[17]

PLACE the following Transfer Switches to AUX:

A.

2-XS-30-83, CRDM CLR 2A-A FAN 1 & 2 B.

2-XS-30-84, CRDM CLR A-A SHROUD SUCTION,

[2-L-11A]

C.

2-XS-67-85, CRDM CLR A-A ERCW OUTLET TCV,

[2-L-11A]

[18]

ENSURE the following Handswitches on 2-L-10 are in P AUTO:

A.

2-HS-30-84C, CRDM CLR A-A SHROUD SUCTION B.

2-HS-67-85C, CRDM CLR A-A ERCW OUTLET TCV

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 72 of 164 Data Package: Page ____ of ____

Date ________

6.2.1 CRDM Cooler 2A-A Logic (continued)

[19]

VERIFY the following:

A.

On Handswitch 2-HS-30-83A, CRDM CLR A-A:



Green Light OFF



Red Light OFF



White Light OFF B.

On 2-XX-55-6E, Train A CISP, Window 105 CRDM CLR A FAN-30-83:



Green Light OFF



Red Light OFF C.

Annunciation & Alarms:



2-XA-55-6F-149B, 480 SD BD 2A1-A/2A2-A/CA VT BD 2A1-A, is in ALARM



Unit 2 Alarm Events Display Screen indicates 149-B 480 SD BD 2A1-A/2A2-A XS IN AUX, is in ALARM (Red).

D.

On Handswitch 2-HS-30-83C, CRDM CLR 2A-A FAN 1 & 2:



Green Light ON



Red Light OFF E.

On Handswitch 2-HS-30-84C, CRDM CLR A-A SHROUD SUCTION:



Green Light ON



Red Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 73 of 164 Data Package: Page ____ of ____

Date ________

6.2.1 CRDM Cooler 2A-A Logic (continued)

F.

At Breaker 2-BKR-30-83, CRDM CLR 2A-A (2-CLR-30-83):



Green Light ON



Red Light OFF

[20]

PLACE Handswitch 2-HS-30-83C, CRDM CLR 2A-A FAN 1 & 2, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-83C:



Green Light OFF



Red Light ON B.

On Handswitch 2-HS-30-84C, CRDM CLR A-A SHROUD SUCTION:



Green Light OFF



Red Light ON C.

At Breaker 2-BKR-30-83, CRDM CLR 2A-A (2-CLR-30-83):



Green Light OFF



Red Light ON D.

Locally:



Cooler 2-CLR-30-83, CRDM COOLER 2A-A, is ON.



Damper 2-TCO-30-84, CRDM COOLER 2A-A SHROUD SUCTION, is OPEN (Acc Crit)



Valve 2-TCV-67-85, CRD VENT CLR 2A-A OUT TEMP CNTL, modulates OPEN. (Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 74 of 164 Data Package: Page ____ of ____

Date ________

6.2.1 CRDM Cooler 2A-A Logic (continued)

[21]

PLACE Handswitch 2-HS-30-83C, CRDM CLR 2A-A FAN 1 & 2, to TRIP, AND VERIFY the following:

A.

On Handswitch 2-HS-30-83C:



Green Light ON



Red Light OFF B.

On Handswitch 2-HS-30-84C, CRDM CLR A-A SHROUD SUCTION:



Green Light ON



Red Light OFF C.

At Breaker 2-BKR-30-83, CRDM CLR 2A-A (2-CLR-30-83):



Green Light ON



Red Light OFF D.

Locally:



Cooler 2-CLR-30-83, CRDM COOLER 2A-A, is OFF.



Damper 2-TCO-30-84, CRDM COOLER 2A-A SHROUD SUCTION, is CLOSED. (Acc Crit)



Valve 2-TCV-67-85, CRD VENT CLR 2A-A OUT TEMP CNTL, is CLOSED. (Acc Crit)

[22]

PLACE Transfer Switch 2-XS-30-83, CRDM CLR 2A-A FAN 1 & 2, to NORMAL.

[23]

PLACE the following Transfer Switches on 2-L-11A to NOR:

A.

2-XS-30-84, CRDM CLR A-A SHROUD SUCTION B.

2-XS-67-85, CRDM CLR A-A ERCW OUTLET TCV

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 75 of 164 Data Package: Page ____ of ____

Date ________

6.2.1 CRDM Cooler 2A-A Logic (continued)

[24]

PLACE Handswitch 2-HS-30-84A, CRDM CLR A-A SHROUD SUCT, to CLOSE.

[25]

VERIFY the following:

A.

On Handswitch 2-HS-30-83A, CRDM CLR A-A:



Green Light ON



Red Light OFF



White Light OFF B.

On 2-XX-55-6E, Train A CISP, Window 105 CRDM CLR A FAN-30-83:



Green Light ON



Red Light OFF C.

Annunciation & Alarms:



2-XA-55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is CLEAR.



Motor Tripout Buzzer, [2-M-2], is OFF.



2-XA-55-6F-149B, 480 SD BD 2A1-A/2A2-A/CA VT BD 2A1-A, is CLEAR.



Unit 2 Alarm Events Display Screen indicates 149-B 480 SD BD 2A1-A/2A2-A XS IN AUX, is NORMAL (Green).

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 76 of 164 Data Package: Page ____ of ____

Date ________

6.2.1 CRDM Cooler 2A-A Logic (continued)

[26]

RACK Breaker 2-BKR-30-83, CRDM CLR 2A-A (2-CLR-30-83), to the REMOVED position.

[27]

REMOVE front cover of Breaker 2-BKR-30-83, CRDM CLR 2A-A (2-CLR-30-83).

1st CV

[28]

PLACE Breaker 2-BKR-30-83, CRDM CLR 2A-A (2-CLR-30-83), Overload Trip Switch (OTS) mechanical lever (DTA plunger) to the TRIP position.

[29]

INSTALL front cover of Breaker 2-BKR-30-83, CRDM CLR 2A-A (2-CLR-30-83).

1st CV

[30]

RACK Breaker 2-BKR-30-83, CRDM CLR 2A-A (2-CLR-30-83), to the CONNECTED position.

[31]

VERIFY the following:

A.

On Handswitch 2-HS-30-83A, CRDM CLR A-A:



Green Light ON



Red Light OFF



White Light ON B.

Annunciation & Alarms:



2-XA 55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is in ALARM.



Unit 2 Alarm Events Display Screen indicates 138-E PANEL M-9 MOTOR TRIPOUT, is in ALARM (Red).



Motor Tripout Buzzer is ON.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 77 of 164 Data Package: Page ____ of ____

Date ________

6.2.1 CRDM Cooler 2A-A Logic (continued)

NOTES

1)

The following step will electrically reset the Overload Trip Switch (OTS) for Breaker 2-BKR-30-83. Refer to Precaution 3.0H for further details.

2)

If the following step does not reset the OTS, then the OTS may be reset manually by pressing the OTS Reset button on the front of the Breaker, and a Test Deficiency Notice shall be initiated.

[32]

RESET the OTS by PLACING Handswitch 2-HS-30-83A, CRDM CLR A-A to STOP, AND VERIFY the following:

A.

On Handswitch 2-HS-30-83A:



Green Light ON



Red Light OFF



White Light OFF B.

Annunciation & Alarms:



2-XA 55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is CLEAR.



Unit 2 Alarm Events Display Screen indicates 138-E PANEL M-9 MOTOR TRIPOUT, is NORMAL (Green).



Motor Tripout Buzzer is OFF.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 78 of 164 Data Package: Page ____ of ____

Date ________

6.2.1 CRDM Cooler 2A-A Logic (continued)

[33]

RECORD the As-Found position of the following Handswitches on 2-M-9, AND IF any of the following Handswitches are found in STOP PULL TO LOCK, THEN PLACE that Handswitch in A AUTO.

A.

2-HS-30-38A, AIR RETURN FAN A-A As-Found:

Place in A AUTO?

 Yes

 No B.

2-HS-30-74A, LWR CNTMT CLR A-A As-Found:

Place in A AUTO?

 Yes

 No C.

2-HS-30-77A, LWR CNTMT CLR C-A As-Found:

Place in A AUTO?

 Yes

 No D.

2-HS-30-88A, CRDM CLR C-A As-Found:

Place in A AUTO?

 Yes

 No

[34]

VERIFY ICS Point HD2030, VENT SYS HS-38A, 88A, 74A, 77A, 83A, displays NOT P-L.

[35]

PLACE Handswitch 2-HS-30-83A, CRDM CLR A-A to STOP PULL TO LOCK, AND VERIFY ICS Point HD2030, VENT SYS HS-38A, 88A, 74A, 77A, 83A, displays PULLT-L.

[36]

PLACE Handswitch 2-HS-30-85A, CRDM CLR A-A LWR CNTMT SUCT, to OPEN.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 79 of 164 Data Package: Page ____ of ____

Date ________

6.2.1 CRDM Cooler 2A-A Logic (continued)

[37]

ENSURE the following Handswitches are returned to their As-Found position recorded in Step 6.2.1[33].

(The As-Left position recorded in this step should match the As-Found position recorded in Step 6.2.1[33].)

A.

2-HS-30-38A, AIR RETURN FAN A-A As-Left:

B.

2-HS-30-74A, LWR CNTMT CLR A-A As-Left:

C.

2-HS-30-77A, LWR CNTMT CLR C-A As-Left:

D.

2-HS-30-88A, CRDM CLR C-A As-Left:

[38]

ENSURE ERCW Temperature Indicating Controller 2-TIC-67-85, CRD VENT CLR 2A TEMP CNTL, is returned to its As-Found positions recorded in Step 4.3[6]A.

Auto/Manual Status:

Indicated Controller Setpoint:

Indicated Controller Output:

1st CV

[39]

VERIFY successful completion of this Subsection 6.2.1.

(Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 80 of 164 Data Package: Page ____ of ____

Date ________

6.2.2 CRDM Cooler 2B-B Logic NOTE Subsection 6.2.2 will be starting a stopping CRDM Cooler 2B-B. Ensure personnel and loose equipment are clear of fan discharge and that personnel in the area are cognizant of expected fan start prior to starting a CRDM Cooler.

[1]

ENSURE all prerequisites listed in Section 4.0 for Section 6.2 and Subsection 6.2.2 have been completed.

[2]

ENSURE Subsections 6.1.3 and 6.1.4 have been completed.

[3]

RACK Breaker 2-BKR-30-92, CRDM CLR 2B-B (2-CLR-30-92), [480V SHUTDOWN BOARD 2B1-B, Compartment 7C], to the TEST position.

[4]

VERIFY 2-XA-55-5C-102A, CRDM COOLER FLOW LO, is CLEAR.

[5]

PRESS the CRDM CLR FAN 2B-B MTR 1 BKR TEST CLOSE switch at Breaker 2-BKR-30-92, CRDM CLR 2B-B (2-CLR-30-92), AND VERIFY the following:

A.

At Breaker 2-BKR-30-92:



Green Light OFF



Red Light ON



Red Flag at Breaker Panel B.

2-XA-55-5C-102A, CRDM COOLER FLOW LO, is in ALARM (after approximately 30 seconds).

C.

Unit 2 Alarm Events Display Screen indicates 102-A CRDM COOLER B-B AIR FLOW LO, is in ALARM (Red).

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 81 of 164 Data Package: Page ____ of ____

Date ________

6.2.2 CRDM Cooler 2B-B Logic (continued)

[6]

PRESS the CRDM CLR FAN 2B-B MTR 1 BKR TEST TRIP switch at Breaker 2-BKR-30-92, CRDM CLR 2B-B (2-CLR-30-92), AND VERIFY the following:

A.

At Breaker 2-BKR-30-92:



Green Light ON



Red Light OFF



Green Flag at Breaker Panel B.

2-XA-55-5C-102A, CRDM COOLER FLOW LO, is CLEAR.

C.

Unit 2 Alarm Events Display Screen indicates 102-A CRDM COOLER B-B AIR FLOW LO, is NORMAL (Green).

[7]

ENSURE Transfer Switch 2-XS-30-92, CRDM CLR 2B-B FAN 1 & 2, [480V SHUTDOWN BOARD 2B1-B, Compartment 5A], is in NORMAL.

[8]

RACK Breaker 2-BKR-30-92, CRDM CLR 2B-B (2-CLR-30-92), to the CONNECTED position.

[9]

PLACE Handswitch 2-HS-30-93A, CRDM CLR B-B SHROUD SUCT, [2-M-9], to P AUTO.

[10]

PLACE Handswitch 2-HS-30-94A, CRDM CLR B-B LWR CNTMT SUCT, [2-M-9], to CLOSE.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 82 of 164 Data Package: Page ____ of ____

Date ________

6.2.2 CRDM Cooler 2B-B Logic (continued)

[11]

VERIFY the following:

A.

Cooler 2-CLR-30-92, CRDM COOLER 2B-B,

[Lwr Cntmt/703 AZ 155], is OFF.

B.

Damper 2-TCO-30-93, CRDM COOLER 2B-B SHROUD SUCTION, [Lwr Cntmt/703 AZ 165], is CLOSED.

C.

2-XA-55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is CLEAR

[12]

PLACE Handswitch 2-HS-30-92A, CRDM CLR B-B, [2-M-9],

to START, AND VERIFY the following:

A.

On Handswitch 2-HS-30-92A:



Green Light OFF



Red Light ON



White Light OFF B.

On Handswitch 2-HS-30-93A, CRDM CLR B-B SHROUD SUCT:



Green Light OFF



Red Light ON C.

On 2-XX-55-6F, Train B CISP, Window 117, CRDM CLR B FAN-30-92, [2-M-6]:



Green Light OFF



Red Light ON D.

2-XA-55-5C-102A, CRDM COOLER FLOW LO, remains CLEAR. (after approximately 30 seconds)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 83 of 164 Data Package: Page ____ of ____

Date ________

6.2.2 CRDM Cooler 2B-B Logic (continued)

E.

On Handswitch 2-HS-30-92C, CRDM CLR 2B-B FAN 1 & 2, [480V SHUTDOWN BOARD 2B1-B, Compartment 5A]:



Green Light OFF



Red Light ON F.

At Breaker 2-BKR-30-92, CRDM CLR 2B-B (2-CLR-30-92):



Green Light OFF



Red Light ON G. Locally:



Cooler 2-CLR-30-92, CRDM COOLER 2B-B, is ON.



Damper 2-TCO-30-93, CRDM COOLER 2B-B SHROUD SUCTION, is OPEN. (Acc Crit)



Valve 2-TCV-67-101, CRD VENT CLR 2B-B OUT TEMP CNTL, [Lwr Cntmt/716 AZ 172 (N Fan Rm)],

modulates OPEN. (Acc Crit)

[13]

VERIFY that the CRDM Cooler 2B-B intake and exhaust air temperature ICS Point Qualities are GOOD (Green).

(Acc Crit)



T1104A, CRDM COOL UNIT C-A B-B INTAKE



T1101A, CRDM COOL UNIT B-B EXHAUST

[14]

RECORD CRDM Cooler 2B-B intake and exhaust air temperatures as indicated by the ICS log points:

T1104A, CRDM COOL UNIT C-A B-B INTAKE:

________________ F T1101A, CRDM COOL UNIT B-B EXHAUST:

________________ F

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 84 of 164 Data Package: Page ____ of ____

Date ________

6.2.2 CRDM Cooler 2B-B Logic (continued)

[15]

PLACE Handswitch 2-HS-30-92A, CRDM CLR B-B, to STOP, AND VERIFY the following:

A.

On Handswitch 2-HS-30-92A:



Green Light ON



Red Light OFF



White Light OFF B.

On Handswitch 2-HS-30-93A, CRDM CLR B-B SHROUD SUCT:



Green Light ON



Red Light OFF C.

On 2-XX-55-6F, Train B CISP, Window 117 CRDM CLR B FAN-30-92:



Green Light ON



Red Light OFF D.

On Handswitch 2-HS-30-92C, CRDM CLR 2B-B FAN 1 & 2:



Green Light ON



Red Light OFF E.

At Breaker 2-BKR-30-92, CRDM CLR 2B-B (2-CLR-30-92):



Green Light ON



Red Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 85 of 164 Data Package: Page ____ of ____

Date ________

6.2.2 CRDM Cooler 2B-B Logic (continued)

F.

Locally:



Cooler 2-CLR-30-92, CRDM COOLER 2B-B, is OFF.



Damper 2-TCO-30-93, CRDM COOLER 2B-B SHROUD SUCTION, is CLOSED. (Acc Crit)



Valve 2-TCV-67-101, CRD VENT CLR 2B-B OUT TEMP CNTL, is CLOSED. (Acc Crit)

[16]

ENSURE 2-XA-55-6F-150B, 480 SD BD 2B1-B/2B2-B/CA VT BD 2B1-B, is CLEAR

[17]

PLACE the following Transfer Switches to AUX:

A.

2-XS-30-92, CRDM CLR 2B-B FAN 1 & 2 B.

2-XS-30-93, CRDM CLR B-B SHROUD SUCTION,

[2-L-11B]

C.

2-XS-67-101, CRDM CLR B-B ERCW OUTLET TCV,

[2-L-11B]

[18]

ENSURE the following Handswitches on 2-L-10 are in P AUTO:

A.

2-HS-30-93C, CRDM CLR B-B SHROUD SUCTION B.

2-HS-67-101C, CRDM CLR B-B ERCW OUTLET TCV

[19]

VERIFY the following:

A.

On Handswitch 2-HS-30-92A, CRDM CLR B-B:



Green Light OFF



Red Light OFF



White Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 86 of 164 Data Package: Page ____ of ____

Date ________

6.2.2 CRDM Cooler 2B-B Logic (continued)

B.

On 2-XX-55-6F, Train B CISP, Window 117 CRDM CLR B FAN-30-92:



Green Light OFF



Red Light OFF C.

Annunciation & Alarms:



2-XA-55-6F-150B, 480 SD BD 2B1-B/2B2-B/CA VT BD 2B1-B, is in ALARM



Unit 2 Alarm Events Display Screen indicates 150-B 480 SD BD 2B1-B/2B2-B XS IN AUX, is in ALARM (Red).

D.

On Handswitch 2-HS-30-92C, CRDM CLR 2B-B FAN 1 & 2:



Green Light ON



Red Light OFF E.

On Handswitch 2-HS-30-93C, CRDM CLR B-B SHROUD SUCTION:



Green Light ON



Red Light OFF F.

At Breaker 2-BKR-30-92, CRDM CLR 2B-B (2-CLR-30-92):



Green Light ON



Red Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 87 of 164 Data Package: Page ____ of ____

Date ________

6.2.2 CRDM Cooler 2B-B Logic (continued)

[20]

PLACE Handswitch 2-HS-30-92C, CRDM CLR 2B-B FAN 1 & 2, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-92C:



Green Light OFF



Red Light ON B.

On Handswitch 2-HS-30-93C, CRDM CLR B-B SHROUD SUCTION:



Green Light OFF



Red Light ON C.

At Breaker 2-BKR-30-92, CRDM CLR 2B-B (2-CLR-30-92):



Green Light OFF



Red Light ON D.

Locally:



Cooler 2-CLR-30-92, CRDM COOLER 2B-B, is ON.



Damper 2-TCO-30-93, CRDM COOLER 2B-B SHROUD SUCTION, is OPEN (Acc Crit)



Valve 2-TCV-67-101, CRD VENT CLR 2B-B OUT TEMP CNTL, modulates OPEN. (Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 88 of 164 Data Package: Page ____ of ____

Date ________

6.2.2 CRDM Cooler 2B-B Logic (continued)

[21]

PLACE Handswitch 2-HS-30-92C, CRDM CLR 2B-B FAN 1 & 2, to TRIP, AND VERIFY the following:

A.

On Handswitch 2-HS-30-92C:



Green Light ON



Red Light OFF B.

On Handswitch 2-HS-30-93C, CRDM CLR B-B SHROUD SUCTION:



Green Light ON



Red Light OFF C.

At Breaker 2-BKR-30-92, CRDM CLR 2B-B (2-CLR-30-92):



Green Light ON



Red Light OFF D.

Locally:



Cooler 2-CLR-30-92, CRDM COOLER 2B-B, is OFF.



Damper 2-TCO-30-93, CRDM COOLER 2B-B SHROUD SUCTION, is CLOSED. (Acc Crit)



Valve 2-TCV-67-101, CRD VENT CLR 2B-B OUT TEMP CNTL, is CLOSED. (Acc Crit)

[22]

PLACE Transfer Switch 2-XS-30-92, CRDM CLR 2B-B FAN 1 & 2, to NORMAL.

[23]

PLACE the following Transfer Switches on 2-L-11B to NOR:

A.

2-XS-30-93, CRDM CLR B-B SHROUD SUCTION B.

2-XS-67-101, CRDM CLR B-B ERCW OUTLET TCV

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 89 of 164 Data Package: Page ____ of ____

Date ________

6.2.2 CRDM Cooler 2B-B Logic (continued)

[24]

PLACE Handswitch 2-HS-30-93A, CRDM CLR B-B SHROUD SUCT, to CLOSE.

[25]

VERIFY the following:

A.

On Handswitch 2-HS-30-92A, CRDM CLR B-B:



Green Light ON



Red Light OFF



White Light OFF B.

On 2-XX-55-6F, Train B CISP, Window 117 CRDM CLR B FAN-30-92:



Green Light ON



Red Light OFF C.

Annunciation & Alarms:



2-XA-55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is CLEAR.



Motor Tripout Buzzer, [2-M-2], is OFF.



2-XA-55-6F-150B, 480 SD BD 2B1-B/2B2-B/CA VT BD 2B1-B, is CLEAR.



Unit 2 Alarm Events Display Screen indicates 150-B 480 SD BD 2B1-B/2B2-B XS IN AUX, is NORMAL (Green).

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 90 of 164 Data Package: Page ____ of ____

Date ________

6.2.2 CRDM Cooler 2B-B Logic (continued)

[26]

RACK Breaker 2-BKR-30-92, CRDM CLR 2B-B (2-CLR-30-92), to the REMOVED position.

[27]

REMOVE front cover of Breaker 2-BKR-30-92, CRDM CLR 2B-B (2-CLR-30-92).

1st CV

[28]

PLACE Breaker 2-BKR-30-92, CRDM CLR 2B-B (2-CLR-30-92), Overload Trip Switch (OTS) mechanical lever (DTA plunger) to the TRIP position.

[29]

INSTALL front cover of Breaker 2-BKR-30-92, CRDM CLR 2B-B (2-CLR-30-92).

1st CV

[30]

RACK Breaker 2-BKR-30-92, CRDM CLR 2B-B (2-CLR-30-92), to the CONNECTED position.

[31]

VERIFY the following:

A.

On Handswitch 2-HS-30-92A, CRDM CLR B-B:



Green Light ON



Red Light OFF



White Light ON B.

Annunciation & Alarms:



2-XA 55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is in ALARM.



Unit 2 Alarm Events Display Screen indicates 138-E PANEL M-9 MOTOR TRIPOUT, is in ALARM (Red).



Motor Tripout Buzzer is ON.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 91 of 164 Data Package: Page ____ of ____

Date ________

6.2.2 CRDM Cooler 2B-B Logic (continued)

NOTES

1)

The following step will electrically reset the Overload Trip Switch (OTS) for Breaker 2-BKR-30-92. Refer to Precaution 3.0H for further details.

2)

If the following step does not reset the OTS, then the OTS may be reset manually by pressing the OTS Reset button on the front of the Breaker, and a Test Deficiency Notice shall be initiated.

[32]

RESET the OTS by PLACING Handswitch 2-HS-30-92A, CRDM CLR B-B to STOP, AND VERIFY the following:

A.

On Handswitch 2-HS-30-92A:



Green Light ON



Red Light OFF



White Light OFF B.

Annunciation & Alarms:



2-XA 55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is CLEAR.



Unit 2 Alarm Events Display Screen indicates 138-E PANEL M-9 MOTOR TRIPOUT, is NORMAL (Green).



Motor Tripout Buzzer is OFF.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 92 of 164 Data Package: Page ____ of ____

Date ________

6.2.2 CRDM Cooler 2B-B Logic (continued)

[33]

RECORD the As-Found position of the following Handswitches on 2-M-9, AND IF any of the following Handswitches are found in STOP PULL TO LOCK, THEN PLACE that Handswitch in A AUTO.

A.

2-HS-30-39A, AIR RETURN FAN B-B As-Found:

Place in A AUTO?

 Yes

 No B.

2-HS-30-75A, LWR CNTMT CLR B-B As-Found:

Place in A AUTO?

 Yes

 No C.

2-HS-30-78A, LWR CNTMT CLR D-B As-Found:

Place in A AUTO?

 Yes

 No D.

2-HS-30-80A, CRDM CLR D-B As-Found:

Place in A AUTO?

 Yes

 No

[34]

VERIFY ICS Point HD2064, VENT SYS HS-39A, 78A, 75A, 92A, 80A, displays NOT P-L.

[35]

PLACE Handswitch 2-HS-30-92A, CRDM CLR B-B to STOP PULL TO LOCK, AND VERIFY ICS Point HD2064, VENT SYS HS-39A, 78A, 75A, 92A, 80A, displays PULLT-L.

[36]

PLACE Handswitch 2-HS-30-94A, CRDM CLR B-B LWR CNTMT SUCT, to OPEN.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 93 of 164 Data Package: Page ____ of ____

Date ________

6.2.2 CRDM Cooler 2B-B Logic (continued)

[37]

ENSURE the following Handswitches are returned to their As-Found position recorded in Step 6.2.2[33].

(The As-Left position recorded in this step should match the As-Found position recorded in Step 6.2.2[33].)

A.

2-HS-30-39A, AIR RETURN FAN B-B As-Left:

B.

2-HS-30-75A, LWR CNTMT CLR B-B As-Left:

C.

2-HS-30-78A, LWR CNTMT CLR D-B As-Left:

D.

2-HS-30-80A, CRDM CLR D-B As-Left:

[38]

ENSURE ERCW Temperature Indicating Controller 2-TIC-67-101, CRD VENT CLR 2B TEMP CNTL, is returned to its As-Found positions recorded in Step 4.3[6]B.

Auto/Manual Status:

Indicated Controller Setpoint:

Indicated Controller Output:

1st CV

[39]

VERIFY successful completion of this Subsection 6.2.2.

(Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 94 of 164 Data Package: Page ____ of ____

Date ________

6.2.3 CRDM Cooler 2C-A Logic NOTE Subsection 6.2.3 will be starting a stopping CRDM Cooler 2C-A. Ensure personnel and loose equipment are clear of fan discharge and that personnel in the area are cognizant of expected fan start prior to starting a CRDM Cooler.

[1]

ENSURE all prerequisites listed in Section 4.0 for Section 6.2 and Subsection 6.2.3 have been completed.

[2]

ENSURE Subsections 6.1.5 and 6.1.6 have been completed.

[3]

RACK Breaker 2-BKR-30-88, CRDM CLR 2C-A (2-CLR-30-88), [480V SHUTDOWN BOARD 2A2-A, Compartment 7A], to the TEST position.

[4]

VERIFY 2-XA-55-5C-102A, CRDM COOLER FLOW LO, is CLEAR.

[5]

PRESS the CRDM CLR FAN 2C-A MTR 1 BKR TEST CLOSE switch at Breaker 2-BKR-30-88, CRDM CLR 2C-A (2-CLR-30-88), AND VERIFY the following:

A.

At Breaker 2-BKR-30-88:



Green Light OFF



Red Light ON



Red Flag at Breaker Panel B.

2-XA-55-5C-102A, CRDM COOLER FLOW LO, is in ALARM (after approximately 30 seconds).

C.

Unit 2 Alarm Events Display Screen indicates 102-A CRDM COOLER C-A AIR FLOW LO, is in ALARM (Red).

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 95 of 164 Data Package: Page ____ of ____

Date ________

6.2.3 CRDM Cooler 2C-A Logic (continued)

[6]

PRESS the CRDM CLR FAN 2C-A MTR 1 BKR TEST TRIP switch at Breaker 2-BKR-30-88, CRDM CLR 2C-A (2-CLR-30-88), AND VERIFY the following:

A.

At Breaker 2-BKR-30-88:



Green Light ON



Red Light OFF



Green Flag at Breaker Panel B.

2-XA-55-5C-102A, CRDM COOLER FLOW LO, is CLEAR.

C.

Unit 2 Alarm Events Display Screen indicates 102-A CRDM COOLER C-A AIR FLOW LO, is NORMAL (Green).

[7]

ENSURE Transfer Switch 2-XS-30-88, CRDM CLR 2C-A FAN 1 & 2, [480V SHUTDOWN BOARD 2A2-A, Compartment 5A], is in NORMAL.

[8]

RACK Breaker 2-BKR-30-88, CRDM CLR 2C-A (2-CLR-30-88), to the CONNECTED position.

[9]

PLACE Handswitch 2-HS-30-89A, CRDM CLR C-A SHROUD SUCT, [2-M-9], to P AUTO.

[10]

PLACE Handswitch 2-HS-30-90A, CRDM CLR C-A LWR CNTMT SUCT, [2-M-9], to CLOSE.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 96 of 164 Data Package: Page ____ of ____

Date ________

6.2.3 CRDM Cooler 2C-A Logic (continued)

[11]

VERIFY the following:

A.

Cooler 2-CLR-30-88, CRDM COOLER 2C-A,

[Lwr Cntmt/703 AZ 205], is OFF.

B.

Damper 2-TCO-30-89, CRDM COOLER 2C-A SHROUD SUCTION, [Lwr Cntmt/703 AZ 195], is CLOSED.

C.

2-XA-55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is CLEAR

[12]

PLACE Handswitch 2-HS-30-88A, CRDM CLR C-A, [2-M-9],

to START, AND VERIFY the following:

A.

On Handswitch 2-HS-30-88A:



Green Light OFF



Red Light ON



White Light OFF B.

On Handswitch 2-HS-30-89A, CRDM CLR C-A SHROUD SUCT:



Green Light OFF



Red Light ON C.

On 2-XX-55-6E, Train A CISP, Window 117, CRDM CLR C FAN-30-88, [2-M-6]:



Green Light OFF



Red Light ON D.

2-XA-55-5C-102A, CRDM COOLER FLOW LO, remains CLEAR. (after approximately 30 seconds)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 97 of 164 Data Package: Page ____ of ____

Date ________

6.2.3 CRDM Cooler 2C-A Logic (continued)

E.

On Handswitch 2-HS-30-88C, CRDM CLR 2C-A FAN 1 & 2, [480V SHUTDOWN BOARD 2A2-A, Compartment 5A]:



Green Light OFF



Red Light ON F.

At Breaker 2-BKR-30-88, CRDM CLR 2C-A (2-CLR-30-88):



Green Light OFF



Red Light ON G. Locally:



Cooler 2-CLR-30-88, CRDM COOLER 2C-A, is ON.



Damper 2-TCO-30-89, CRDM COOLER 2C-A SHROUD SUCTION, is OPEN. (Acc Crit)



Valve 2-TCV-67-93, CRD VENT CLR 2C-A OUT TEMP CNTL, [Lwr Cntmt/716 AZ 188 (N Fan Rm)],

modulates OPEN. (Acc Crit)

[13]

VERIFY that the CRDM Cooler 2C-A intake and exhaust air temperature ICS Point Qualities are GOOD (Green).

(Acc Crit)



T1104A, CRDM COOL UNIT C-A B-B INTAKE



T1102A, CRDM COOL UNIT C-A EXHAUST

[14]

RECORD CRDM Cooler 2C-A intake and exhaust air temperatures as indicated by the ICS log points:

T1104A, CRDM COOL UNIT C-A B-B INTAKE:

________________ F T1102A, CRDM COOL UNIT C-A EXHAUST:

________________ F

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 98 of 164 Data Package: Page ____ of ____

Date ________

6.2.3 CRDM Cooler 2C-A Logic (continued)

[15]

PLACE Handswitch 2-HS-30-88A, CRDM CLR C-A, to STOP, AND VERIFY the following:

A.

On Handswitch 2-HS-30-88A:



Green Light ON



Red Light OFF



White Light OFF B.

On Handswitch 2-HS-30-89A, CRDM CLR C-A SHROUD SUCT:



Green Light ON



Red Light OFF C.

On 2-XX-55-6E, Train A CISP, Window 117 CRDM CLR C FAN-30-88:



Green Light ON



Red Light OFF D.

On Handswitch 2-HS-30-88C, CRDM CLR 2C-A FAN 1 & 2:



Green Light ON



Red Light OFF E.

At Breaker 2-BKR-30-88, CRDM CLR 2C-A (2-CLR-30-88):



Green Light ON



Red Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 99 of 164 Data Package: Page ____ of ____

Date ________

6.2.3 CRDM Cooler 2C-A Logic (continued)

F.

Locally:



Cooler 2-CLR-30-88, CRDM COOLER 2C-A, is OFF.



Damper 2-TCO-30-89, CRDM COOLER 2C-A SHROUD SUCTION, is CLOSED. (Acc Crit)



Valve 2-TCV-67-93, CRD VENT CLR 2C-A OUT TEMP CNTL, is CLOSED. (Acc Crit)

[16]

ENSURE 2-XA-55-6F-149B, 480 SD BD 2A1-A/2A2-A/CA VT BD 2A1-A, is CLEAR

[17]

PLACE the following Transfer Switches to AUX:

A.

2-XS-30-88, CRDM CLR 2C-A FAN 1 & 2 B.

2-XS-30-89, CRDM CLR C-A SHROUD SUCTION,

[2-L-11A]

C.

2-XS-67-93, CRDM CLR C-A ERCW OUTLET TCV,

[2-L-11A]

[18]

ENSURE the following Handswitches on 2-L-10 are in P AUTO:

A.

2-HS-30-89C, CRDM CLR C-A SHROUD SUCTION B.

2-HS-67-93C, CRDM CLR C-A ERCW OUTLET TCV

[19]

VERIFY the following:

A.

On Handswitch 2-HS-30-88A, CRDM CLR C-A:



Green Light OFF



Red Light OFF



White Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 100 of 164 Data Package: Page ____ of ____

Date ________

6.2.3 CRDM Cooler 2C-A Logic (continued)

B.

On 2-XX-55-6E, Train A CISP, Window 117 CRDM CLR C FAN-30-88:



Green Light OFF



Red Light OFF C.

Annunciation & Alarms:



2-XA-55-6F-149B, 480 SD BD 2A1-A/2A2-A/CA VT BD 2A1-A, is in ALARM



Unit 2 Alarm Events Display Screen indicates 149-B 480 SD BD 2A1-A/2A2-A XS IN AUX, is in ALARM (Red).

D.

On Handswitch 2-HS-30-88C, CRDM CLR 2C-A FAN 1 & 2:



Green Light ON



Red Light OFF E.

On Handswitch 2-HS-30-89C, CRDM CLR C-A SHROUD SUCTION:



Green Light ON



Red Light OFF F.

At Breaker 2-BKR-30-88, CRDM CLR 2C-A (2-CLR-30-88):



Green Light ON



Red Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 101 of 164 Data Package: Page ____ of ____

Date ________

6.2.3 CRDM Cooler 2C-A Logic (continued)

[20]

PLACE Handswitch 2-HS-30-88C, CRDM CLR 2C-A FAN 1 & 2, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-88C:



Green Light OFF



Red Light ON B.

On Handswitch 2-HS-30-89C, CRDM CLR C-A SHROUD SUCTION:



Green Light OFF



Red Light ON C.

At Breaker 2-BKR-30-88, CRDM CLR 2C-A (2-CLR-30-88):



Green Light OFF



Red Light ON D.

Locally:



Cooler 2-CLR-30-88, CRDM COOLER 2C-A, is ON.



Damper 2-TCO-30-89, CRDM COOLER 2C-A SHROUD SUCTION, is OPEN (Acc Crit)



Valve 2-TCV-67-93, CRD VENT CLR 2C-A OUT TEMP CNTL, modulates OPEN. (Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 102 of 164 Data Package: Page ____ of ____

Date ________

6.2.3 CRDM Cooler 2C-A Logic (continued)

[21]

PLACE Handswitch 2-HS-30-88C, CRDM CLR 2C-A FAN 1 & 2, to TRIP, AND VERIFY the following:

A.

On Handswitch 2-HS-30-88C:



Green Light ON



Red Light OFF B.

On Handswitch 2-HS-30-89C, CRDM CLR C-A SHROUD SUCTION:



Green Light ON



Red Light OFF C.

At Breaker 2-BKR-30-88, CRDM CLR 2C-A (2-CLR-30-88):



Green Light ON



Red Light OFF D.

Locally:



Cooler 2-CLR-30-88, CRDM COOLER 2C-A, is OFF.



Damper 2-TCO-30-89, CRDM COOLER 2C-A SHROUD SUCTION, is CLOSED. (Acc Crit)



Valve 2-TCV-67-93, CRD VENT CLR 2C-A OUT TEMP CNTL, is CLOSED. (Acc Crit)

[22]

PLACE Transfer Switch 2-XS-30-88, CRDM CLR 2C-A FAN 1 & 2, to NORMAL.

[23]

PLACE the following Transfer Switches on 2-L-11A to NOR:

A.

2-XS-30-89, CRDM CLR C-A SHROUD SUCTION B.

2-XS-67-93, CRDM CLR C-A ERCW OUTLET TCV

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 103 of 164 Data Package: Page ____ of ____

Date ________

6.2.3 CRDM Cooler 2C-A Logic (continued)

[24]

PLACE Handswitch 2-HS-30-89A, CRDM CLR C-A SHROUD SUCT, to CLOSE.

[25]

VERIFY the following:

A.

On Handswitch 2-HS-30-88A, CRDM CLR C-A:



Green Light ON



Red Light OFF



White Light OFF B.

On 2-XX-55-6E, Train A CISP, Window 117 CRDM CLR C FAN-30-88:



Green Light ON



Red Light OFF C.

Annunciation & Alarms:



2-XA-55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is CLEAR.



Motor Tripout Buzzer, [2-M-2], is OFF.



2-XA-55-6F-149B, 480 SD BD 2A1-A/2A2-A/CA VT BD 2A1-A, is CLEAR.



Unit 2 Alarm Events Display Screen indicates 149-B 480 SD BD 2A1-A/2A2-A XS IN AUX, is NORMAL (Green).

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 104 of 164 Data Package: Page ____ of ____

Date ________

6.2.3 CRDM Cooler 2C-A Logic (continued)

[26]

RACK Breaker 2-BKR-30-88, CRDM CLR 2C-A (2-CLR-30-88), to the REMOVED position.

[27]

REMOVE front cover of Breaker 2-BKR-30-88, CRDM CLR 2C-A (2-CLR-30-88).

1st CV

[28]

PLACE Breaker 2-BKR-30-88, CRDM CLR 2C-A (2-CLR-30-88), Overload Trip Switch (OTS) mechanical lever (DTA plunger) to the TRIP position.

[29]

INSTALL front cover of Breaker 2-BKR-30-88, CRDM CLR 2C-A (2-CLR-30-88).

1st CV

[30]

RACK Breaker 2-BKR-30-88, CRDM CLR 2C-A (2-CLR-30-88), to the CONNECTED position.

[31]

VERIFY the following:

A.

On Handswitch 2-HS-30-88A, CRDM CLR C-A:



Green Light ON



Red Light OFF



White Light ON B.

Annunciation & Alarms:



2-XA 55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is in ALARM.



Unit 2 Alarm Events Display Screen indicates 138-E PANEL M-9 MOTOR TRIPOUT, is in ALARM (Red).



Motor Tripout Buzzer is ON.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 105 of 164 Data Package: Page ____ of ____

Date ________

6.2.3 CRDM Cooler 2C-A Logic (continued)

NOTES

1)

The following step will electrically reset the Overload Trip Switch (OTS) for Breaker 2-BKR-30-88. Refer to Precaution 3.0H for further details.

2)

If the following step does not reset the OTS, then the OTS may be reset manually by pressing the OTS Reset button on the front of the Breaker, and a Test Deficiency Notice shall be initiated.

[32]

RESET the OTS by PLACING Handswitch 2-HS-30-88A, CRDM CLR C-A to STOP, AND VERIFY the following:

A.

On Handswitch 2-HS-30-88A:



Green Light ON



Red Light OFF



White Light OFF B.

Annunciation & Alarms:



2-XA 55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is CLEAR.



Unit 2 Alarm Events Display Screen indicates 138-E PANEL M-9 MOTOR TRIPOUT, is NORMAL (Green).



Motor Tripout Buzzer is OFF.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 106 of 164 Data Package: Page ____ of ____

Date ________

6.2.3 CRDM Cooler 2C-A Logic (continued)

[33]

RECORD the As-Found position of the following Handswitches on 2-M-9, AND IF any of the following Handswitches are found in STOP PULL TO LOCK, THEN PLACE that Handswitch in A AUTO.

A.

2-HS-30-38A, AIR RETURN FAN A-A As-Found:

Place in A AUTO?

 Yes

 No B.

2-HS-30-74A, LWR CNTMT CLR A-A As-Found:

Place in A AUTO?

 Yes

 No C.

2-HS-30-77A, LWR CNTMT CLR C-A As-Found:

Place in A AUTO?

 Yes

 No D.

2-HS-30-83A, CRDM CLR A-A As-Found:

Place in A AUTO?

 Yes

 No

[34]

VERIFY ICS Point HD2030, VENT SYS HS-38A, 88A, 74A, 77A, 83A, displays NOT P-L.

[35]

PLACE Handswitch 2-HS-30-88A, CRDM CLR C-A to STOP PULL TO LOCK, AND VERIFY ICS Point HD2030, VENT SYS HS-38A, 88A, 74A, 77A, 83A, displays PULLT-L.

[36]

PLACE Handswitch 2-HS-30-90A, CRDM CLR C-A LWR CNTMT SUCT, to OPEN.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 107 of 164 Data Package: Page ____ of ____

Date ________

6.2.3 CRDM Cooler 2C-A Logic (continued)

[37]

ENSURE the following Handswitches are returned to their As-Found position recorded in Step 6.2.3[33].

(The As-Left position recorded in this step should match the As-Found position recorded in Step 6.2.3[33].)

A.

2-HS-30-38A, AIR RETURN FAN A-A As-Left:

B.

2-HS-30-74A, LWR CNTMT CLR A-A As-Left:

C.

2-HS-30-77A, LWR CNTMT CLR C-A As-Left:

D.

2-HS-30-83A, CRDM CLR A-A As-Left:

[38]

ENSURE ERCW Temperature Indicating Controller 2-TIC-67-93, CRD VENT CLR 2C TEMP CNTL, is returned to its As-Found positions recorded in Step 4.3[6]C.

Auto/Manual Status:

Indicated Controller Setpoint:

Indicated Controller Output:

1st CV

[39]

VERIFY successful completion of this Subsection 6.2.3.

(Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 108 of 164 Data Package: Page ____ of ____

Date ________

6.2.4 CRDM Cooler 2D-B Logic NOTE Subsection 6.2.4 will be starting a stopping CRDM Cooler 2D-B. Ensure personnel and loose equipment are clear of fan discharge and that personnel in the area are cognizant of expected fan start prior to starting a CRDM Cooler.

[1]

ENSURE all prerequisites listed in Section 4.0 for Section 6.2 and Subsection 6.2.4 have been completed.

[2]

ENSURE Subsections 6.1.7 and 6.1.8 have been completed.

[3]

RACK Breaker 2-BKR-30-80, CRDM CLR 2D-B (2-CLR-30-80), [480V SHUTDOWN BOARD 2B2-B, Compartment 7B], to the TEST position.

[4]

VERIFY 2-XA-55-5C-102A, CRDM COOLER FLOW LO, is CLEAR.

[5]

PRESS the CRDM CLR FAN 2D-B MTR 1 BKR TEST CLOSE switch at 2-BKR-30-80, CRDM CLR 2D-B (2-CLR-30-80), AND VERIFY the following:

A.

At Breaker 2-BKR-30-80:



Green Light OFF



Red Light ON



Red Flag at Breaker Panel B.

2-XA-55-5C-102A, CRDM COOLER FLOW LO, is in ALARM (after approximately 30 seconds).

C.

Unit 2 Alarm Events Display Screen indicates 102-A CRDM COOLER D-B AIR FLOW LO, is in ALARM (Red).

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 109 of 164 Data Package: Page ____ of ____

Date ________

6.2.4 CRDM Cooler 2D-B Logic (continued)

[6]

PRESS the CRDM CLR FAN 2D-B MTR 1 BKR TEST TRIP switch at 2-BKR-30-80, CRDM CLR 2D-B (2-CLR-30-80), AND VERIFY the following:

A.

At Breaker 2-BKR-30-80:



Green Light ON



Red Light OFF



Green Flag at Breaker Panel B.

2-XA-55-5C-102A, CRDM COOLER FLOW LO, is CLEAR.

C.

Unit 2 Alarm Events Display Screen indicates 102-A CRDM COOLER D-B AIR FLOW LO, is NORMAL (Green).

[7]

ENSURE Transfer Switch 2-XS-30-80, CRDM CLR 2D-B FAN 1 & 2, [480V SHUTDOWN BOARD 2B2-B, Compartment 5A], is in NORMAL.

[8]

RACK Breaker 2-BKR-30-80, CRDM CLR 2D-B (2-CLR-30-80), to the CONNECTED position.

[9]

PLACE Handswitch 2-HS-30-81A, CRDM CLR D-B SHROUD SUCT, [2-M-9], to P AUTO.

[10]

PLACE Handswitch 2-HS-30-82A, CRDM CLR D-B LWR CNTMT SUCT, [2-M-9], to CLOSE.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 110 of 164 Data Package: Page ____ of ____

Date ________

6.2.4 CRDM Cooler 2D-B Logic (continued)

[11]

VERIFY the following:

A.

Cooler 2-CLR-30-80, CRDM COOLER 2D-B,

[Lwr Cntmt/703 AZ 335], is OFF.

B.

Damper 2-TCO-30-81, CRDM COOLER 2D-B SHROUD SUCTION, [Lwr Cntmt/703 AZ 345], is CLOSED.

C.

2-XA-55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is CLEAR

[12]

PLACE Handswitch 2-HS-30-80A, CRDM CLR D-B, [2-M-9],

to START, AND VERIFY the following:

A.

On Handswitch 2-HS-30-80A:



Green Light OFF



Red Light ON



White Light OFF B.

On Handswitch 2-HS-30-81A, CRDM CLR D-B SHROUD SUCT:



Green Light OFF



Red Light ON C.

On 2-XX-55-6F, Train B CISP, Window 105, CRDM CLR D FAN-30-80, [2-M-6]:



Green Light OFF



Red Light ON D.

2-XA-55-5C-102A, CRDM COOLER FLOW LO, remains CLEAR. (after approximately 30 seconds)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 111 of 164 Data Package: Page ____ of ____

Date ________

6.2.4 CRDM Cooler 2D-B Logic (continued)

E.

On Handswitch 2-HS-30-80C, CRDM CLR 2D-B FAN 1 & 2, [480V SHUTDOWN BOARD 2B2-B, Compartment 5A]:



Green Light OFF



Red Light ON F.

At Breaker 2-BKR-30-80, CRDM CLR 2D-B (2-CLR-30-80):



Green Light OFF



Red Light ON G. Locally:



Cooler 2-CLR-30-80, CRDM COOLER 2D-B, is ON.



Damper 2-TCO-30-81, CRDM COOLER 2D-B SHROUD SUCTION, is OPEN. (Acc Crit)



Valve 2-TCV-67-109, CRD VENT CLR 2D-B OUT TEMP CNTL, [Lwr Cntmt/716 AZ 352 (S Fan Rm)],

modulates OPEN. (Acc Crit)

[13]

VERIFY that the CRDM Cooler 2D-B intake and exhaust air temperature ICS Point Qualities are GOOD (Green).

(Acc Crit)



T1105A, CRDM COOL UNIT A-A D-B INTAKE



T1103A, CRDM COOL UNIT D-B EXHAUST

[14]

RECORD CRDM Cooler 2D-B intake and exhaust air temperatures as indicated by the ICS log points:

T1105A, CRDM COOL UNIT A-A D-B INTAKE:

________________ F T1103A, CRDM COOL UNIT D-B EXHAUST:

________________ F

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 112 of 164 Data Package: Page ____ of ____

Date ________

6.2.4 CRDM Cooler 2D-B Logic (continued)

[15]

PLACE Handswitch 2-HS-30-80A, CRDM CLR D-B, to STOP, AND VERIFY the following:

A.

On Handswitch 2-HS-30-80A:



Green Light ON



Red Light OFF



White Light OFF B.

On Handswitch 2-HS-30-81A, CRDM CLR D-B SHROUD SUCT:



Green Light ON



Red Light OFF C.

On 2-XX-55-6F, Train B CISP, Window 105 CRDM CLR D FAN-30-80:



Green Light ON



Red Light OFF D.

On Handswitch 2-HS-30-80C, CRDM CLR 2D-B FAN 1 & 2:



Green Light ON



Red Light OFF E.

At Breaker 2-BKR-30-80, CRDM CLR 2D-B (2-CLR-30-80):



Green Light ON



Red Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 113 of 164 Data Package: Page ____ of ____

Date ________

6.2.4 CRDM Cooler 2D-B Logic (continued)

F.

Locally:



Cooler 2-CLR-30-80, CRDM COOLER 2D-B, is OFF.



Damper 2-TCO-30-81, CRDM COOLER 2D-B SHROUD SUCTION, is CLOSED. (Acc Crit)



Valve 2-TCV-67-109, CRD VENT CLR 2D-B OUT TEMP CNTL, is CLOSED. (Acc Crit)

[16]

ENSURE 2-XA-55-6F-150B, 480 SD BD 2B1-B/2B2-B/CA VT BD 2B1-B, is CLEAR

[17]

PLACE the following Transfer Switches to AUX:

A.

2-XS-30-80, CRDM CLR 2D-B FAN 1 & 2 B.

2-XS-30-81, CRDM CLR D-B SHROUD SUCTION,

[2-L-11B]

C.

2-XS-67-109, CRDM CLR D-B ERCW OUTLET TCV,

[2-L-11B]

[18]

ENSURE the following Handswitches on 2-L-10 are in P AUTO:

A.

2-HS-30-81C, CRDM CLR D-B SHROUD SUCTION B.

2-HS-67-109C, CRDM CLR D-B ERCW OUTLET TCV

[19]

VERIFY the following:

A.

On Handswitch 2-HS-30-80A, CRDM CLR D-B:



Green Light OFF



Red Light OFF



White Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 114 of 164 Data Package: Page ____ of ____

Date ________

6.2.4 CRDM Cooler 2D-B Logic (continued)

B.

On 2-XX-55-6F, Train B CISP, Window 105 CRDM CLR D FAN-30-80:



Green Light OFF



Red Light OFF C.

Annunciation & Alarms:



2-XA-55-6F-150B, 480 SD BD 2B1-B/2B2-B/CA VT BD 2B1-B, is in ALARM



Unit 2 Alarm Events Display Screen indicates 150-B 480 SD BD 2B1-B/2B2-B XS IN AUX, is in ALARM (Red).

D.

On Handswitch 2-HS-30-80C, CRDM CLR 2D-B FAN 1 & 2:



Green Light ON



Red Light OFF E.

On Handswitch 2-HS-30-81C, CRDM CLR D-B SHROUD SUCTION:



Green Light ON



Red Light OFF F.

At Breaker 2-BKR-30-80, CRDM CLR 2D-B (2-CLR-30-80):



Green Light ON



Red Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 115 of 164 Data Package: Page ____ of ____

Date ________

6.2.4 CRDM Cooler 2D-B Logic (continued)

[20]

PLACE Handswitch 2-HS-30-80C, CRDM CLR 2D-B FAN 1 & 2, to CLOSE, AND VERIFY the following:

A.

On Handswitch 2-HS-30-80C:



Green Light OFF



Red Light ON B.

On Handswitch 2-HS-30-81C, CRDM CLR D-B SHROUD SUCTION:



Green Light OFF



Red Light ON C.

At Breaker 2-BKR-30-80, CRDM CLR 2D-B (2-CLR-30-80):



Green Light OFF



Red Light ON D.

Locally:



Cooler 2-CLR-30-80, CRDM COOLER 2D-B, is ON.



Damper 2-TCO-30-81, CRDM COOLER 2D-B SHROUD SUCTION, is OPEN (Acc Crit)



Valve 2-TCV-67-109, CRD VENT CLR 2D-B OUT TEMP CNTL, modulates OPEN. (Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 116 of 164 Data Package: Page ____ of ____

Date ________

6.2.4 CRDM Cooler 2D-B Logic (continued)

[21]

PLACE Handswitch 2-HS-30-80C, CRDM CLR 2D-B FAN 1 & 2, to TRIP, AND VERIFY the following:

A.

On Handswitch 2-HS-30-80C:



Green Light ON



Red Light OFF B.

On Handswitch 2-HS-30-81C, CRDM CLR D-B SHROUD SUCTION:



Green Light ON



Red Light OFF C.

At Breaker 2-BKR-30-80, CRDM CLR 2D-B (2-CLR-30-80):



Green Light ON



Red Light OFF D.

Locally:



Cooler 2-CLR-30-80, CRDM COOLER 2D-B, is OFF.



Damper 2-TCO-30-81, CRDM COOLER 2D-B SHROUD SUCTION, is CLOSED. (Acc Crit)



Valve 2-TCV-67-109, CRD VENT CLR 2D-B OUT TEMP CNTL, is CLOSED. (Acc Crit)

[22]

PLACE Transfer Switch 2-XS-30-80, CRDM CLR 2D-B FAN 1 & 2, to NORMAL.

[23]

PLACE the following Transfer Switches on 2-L-11B to NOR:

A.

2-XS-30-81, CRDM CLR D-B SHROUD SUCTION B.

2-XS-67-109, CRDM CLR D-B ERCW OUTLET TCV

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 117 of 164 Data Package: Page ____ of ____

Date ________

6.2.4 CRDM Cooler 2D-B Logic (continued)

[24]

PLACE Handswitch 2-HS-30-81A, CRDM CLR D-B SHROUD SUCT, to CLOSE.

[25]

VERIFY the following:

A.

On Handswitch 2-HS-30-80A, CRDM CLR D-B:



Green Light ON



Red Light OFF



White Light OFF B.

On 2-XX-55-6F, Train B CISP, Window 105 CRDM CLR D FAN-30-80:



Green Light ON



Red Light OFF C.

Annunciation & Alarms:



2-XA-55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is CLEAR.



Motor Tripout Buzzer, [2-M-2], is OFF.



2-XA-55-6F-150B, 480 SD BD 2B1-B/2B2-B/CA VT BD 2B1-B, is CLEAR.



Unit 2 Alarm Events Display Screen indicates 150-B 480 SD BD 2B1-B/2B2-B XS IN AUX, is NORMAL (Green).

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 118 of 164 Data Package: Page ____ of ____

Date ________

6.2.4 CRDM Cooler 2D-B Logic (continued)

[26]

RACK Breaker 2-BKR-30-80, CRDM CLR 2D-B (2-CLR-30-80), to the REMOVED position.

[27]

REMOVE front cover Plate of Breaker 2-BKR-30-80, CRDM CLR 2D-B (2-CLR-30-80).

1st CV

[28]

PLACE Breaker 2-BKR-30-80, CRDM CLR 2D-B (2-CLR-30-80), Overload Trip Switch (OTS) mechanical lever (DTA plunger) to the TRIP position.

[29]

INSTALL front cover Plate of Breaker 2-BKR-30-80, CRDM CLR 2D-B (2-CLR-30-80).

1st CV

[30]

RACK Breaker 2-BKR-30-80, CRDM CLR 2D-B (2-CLR-30-80), to the CONNECTED position.

[31]

VERIFY the following:

A.

On Handswitch 2-HS-30-80A, CRDM CLR D-B:



Green Light ON



Red Light OFF



White Light ON B.

Annunciation & Alarms:



2-XA 55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is in ALARM.



Unit 2 Alarm Events Display Screen indicates 138-E PANEL M-9 MOTOR TRIPOUT, is in ALARM (Red).



Motor Tripout Buzzer is ON.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 119 of 164 Data Package: Page ____ of ____

Date ________

6.2.4 CRDM Cooler 2D-B Logic (continued)

NOTES

1)

The following step will electrically reset the Overload Trip Switch (OTS) for Breaker 2-BKR-30-80. Refer to Precaution 3.0H for further details.

2)

If the following step does not reset the OTS, then the OTS may be reset manually by pressing the OTS Reset button on the front of the Breaker, and a Test Deficiency Notice shall be initiated.

[32]

RESET the OTS by PLACING Handswitch 2-HS-30-80A, CRDM CLR D-B to STOP, AND VERIFY the following:

A.

On Handswitch 2-HS-30-80A:



Green Light ON



Red Light OFF



White Light OFF B.

Annunciation & Alarms:



2-XA 55-6E-138E, PANEL M-9 MOTOR TRIPOUT, is CLEAR.



Unit 2 Alarm Events Display Screen indicates 138-E PANEL M-9 MOTOR TRIPOUT, is NORMAL (Green).



Motor Tripout Buzzer is OFF.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 120 of 164 Data Package: Page ____ of ____

Date ________

6.2.4 CRDM Cooler 2D-B Logic (continued)

[33]

RECORD the As-Found position of the following Handswitches on 2-M-9, AND IF any of the following Handswitches are found in STOP PULL TO LOCK, THEN PLACE that Handswitch in A AUTO.

A.

2-HS-30-39A, AIR RETURN FAN B-B As-Found:

Place in A AUTO?

 Yes

 No B.

2-HS-30-75A, LWR CNTMT CLR B-B As-Found:

Place in A AUTO?

 Yes

 No C.

2-HS-30-78A, LWR CNTMT CLR D-B As-Found:

Place in A AUTO?

 Yes

 No D.

2-HS-30-92A, CRDM CLR B-B As-Found:

Place in A AUTO?

 Yes

 No

[34]

VERIFY ICS Point HD2064, VENT SYS HS-39A, 78A, 75A, 92A, 80A, displays NOT P-L.

[35]

PLACE Handswitch 2-HS-30-80A, CRDM CLR D-B to STOP PULL TO LOCK, AND VERIFY ICS Point HD2064, VENT SYS HS-39A, 78A, 75A, 92A, 80A, displays PULLT-L.

[36]

PLACE Handswitch 2-HS-30-82A, CRDM CLR D-B LWR CNTMT SUCT, to OPEN.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 121 of 164 Data Package: Page ____ of ____

Date ________

6.2.4 CRDM Cooler 2D-B Logic (continued)

[37]

ENSURE the following Handswitches are returned to their As-Found position recorded in Step 6.2.4[33].

(The As-Left position recorded in this step should match the As-Found position recorded in Step 6.2.4[33].)

A.

2-HS-30-39A, AIR RETURN FAN B-B As-Left:

B.

2-HS-30-75A, LWR CNTMT CLR B-B As-Left:

C.

2-HS-30-78A, LWR CNTMT CLR D-B As-Left:

D.

2-HS-30-92A, CRDM CLR B-B As-Left:

[38]

ENSURE ERCW Temperature Indicating Controller 2-TIC-67-109, CRD VENT CLR 2D TEMP CNTL, is returned to its As-Found positions recorded in Step 4.3[6]D.

Auto/Manual Status:

Indicated Controller Setpoint:

Indicated Controller Output:

1st CV

[39]

VERIFY successful completion of this Subsection 6.2.4.

(Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 122 of 164 Data Package: Page ____ of ____

Date ________

6.3 CRDM Coolers Response to Phase B Containment Isolation Signal NOTE Subsections 6.3.1 and 6.3.2 may be performed in any order, provided their applicable predecessor Subsections are completed. Unless otherwise noted, the steps within each Subsection shall be performed in the order written. The diagram at the beginning of Section 6.0 may be used as a placekeeping tool throughout the performance of this Section.

6.3.1 Train A CRDM Coolers (2A-A and 2C-A)

NOTE Subsection 6.3.1 will be starting a stopping CRDM Cooler 2A-A and 2C-A. Ensure personnel and loose equipment are clear of fan discharge and that personnel in the area are cognizant of expected fan start prior to starting a CRDM Cooler.

[1]

ENSURE all prerequisites listed in Section 4.0 for Section 6.3 have been completed.

[2]

ENSURE Subsections 6.2.1 and 6.2.3 have been completed.

[3]

PLACE Handswitch 2-HS-30-83A, CRDM CLR A-A, to START, AND VERIFY on Handswitch 2-HS-30-83A:



Green Light OFF



Red Light ON

[4]

PLACE Handswitch 2-HS-30-88A, CRDM CLR C-A, to START, AND VERIFY on Handswitch 2-HS-30-88A:



Green Light OFF



Red Light ON

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 123 of 164 Data Package: Page ____ of ____

Date ________

6.3.1 Train A CRDM Coolers (2A-A and 2C-A) (continued)

[5]

ENSURE the following Lower Compartment Coolers are OFF:



2-CCU-30-74, CNTMT LOWER COMPARTMENT COOLER 2A-A



2-CCU-30-77, CNTMT LOWER COMPARTMENT COOLER 2C-A NOTE The following steps will simulate a Train A Phase B Containment Isolation Signal and Phase B signal reset by closing and opening a test switch (TS-1, installed in Step 4.3[13.1])

in SSPS Train A Output Cabinet 2-R-48.

[6]

PLACE Test Switch TS-1 in the CLOSED (ON) position.

[7]

VERIFY the following:

A.

On Handswitch 2-HS-30-83A, CRDM CLR A-A:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

B.

On Handswitch 2-HS-30-88A, CRDM CLR C-A:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

[8]

PLACE Test Switch TS-1 in the OPEN (OFF) position.

[9]

VERIFY the following:

A.

On Handswitch 2-HS-30-83A, CRDM CLR A-A:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

B.

On Handswitch 2-HS-30-88A, CRDM CLR C-A:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 124 of 164 Data Package: Page ____ of ____

Date ________

6.3.1 Train A CRDM Coolers (2A-A and 2C-A) (continued)

[10]

PLACE the following Transfer Switches in AUX:

A.

2-XS-30-83, CRDM CLR 2A-A FAN 1 & 2 B.

2-XS-30-88, CRDM CLR 2C-A FAN 1 & 2

[11]

PLACE Test Switch TS-1 in the CLOSED (ON) position.

[12]

VERIFY the following:

A.

On Handswitch 2-HS-30-83C, CRDM CLR 2A-A FAN 1 & 2:



Green Light ON



Red Light OFF B.

On Handswitch 2-HS-30-88C, CRDM CLR 2C-A FAN 1 & 2:



Green Light ON



Red Light OFF

[13]

PLACE Handswitch 2-HS-30-83C, CRDM CLR 2A-A FAN 1 & 2, to CLOSE, AND VERIFY the following on Handswitch 2-HS-30-83C:



Green Light OFF (Acc Crit)



Red Light ON (Acc Crit)

[14]

PLACE Handswitch 2-HS-30-83C, CRDM CLR 2A-A FAN 1 & 2, to TRIP, AND VERIFY the following on Handswitch 2-HS-30-83C:



Green Light ON



Red Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 125 of 164 Data Package: Page ____ of ____

Date ________

6.3.1 Train A CRDM Coolers (2A-A and 2C-A) (continued)

[15]

PLACE Handswitch 2-HS-30-88C, CRDM CLR 2C-A FAN 1 & 2, to CLOSE, AND VERIFY the following on Handswitch 2-HS-30-88C:



Green Light OFF (Acc Crit)



Red Light ON (Acc Crit)

[16]

PLACE Handswitch 2-HS-30-88C, CRDM CLR 2C-A FAN 1 & 2, to TRIP, AND VERIFY on Handswitch 2-HS-30-88C:



Green Light ON



Red Light OFF

[17]

PLACE Test Switch TS-1 in the OPEN (OFF) position.

[18]

VERIFY the following:

A.

On Handswitch 2-HS-30-83C, CRDM CLR 2A-A FAN 1 & 2:



Green Light ON



Red Light OFF B.

On Handswitch 2-HS-30-88C, CRDM CLR 2C-A FAN 1 & 2:



Green Light ON



Red Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 126 of 164 Data Package: Page ____ of ____

Date ________

6.3.1 Train A CRDM Coolers (2A-A and 2C-A) (continued)

[19]

PLACE the following Transfer Switches in NORMAL:

A.

2-XS-30-83, CRDM CLR 2A-A FAN 1 & 2 B.

2-XS-30-88, CRDM CLR 2C-A FAN 1 & 2

[20]

PLACE the following Handswitches in STOP PULL TO LOCK:

A.

2-HS-30-83A, CRDM CLR A-A B.

2-HS-30-88A, CRDM CLR C-A

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 127 of 164 Data Package: Page ____ of ____

Date ________

6.3.2 Train B CRDM Coolers (2B-B and 2D-B)

NOTE Subsection 6.3.2 will be starting a stopping CRDM Cooler 2B-B and 2D-B. Ensure personnel and loose equipment are clear of fan discharge and that personnel in the area are cognizant of expected fan start prior to starting a CRDM Cooler.

[1]

ENSURE all prerequisites listed in Section 4.0 for Section 6.3 have been completed.

[2]

ENSURE Subsections 6.2.2 and 6.2.4 have been completed.

[3]

PLACE Handswitch 2-HS-30-92A, CRDM CLR B-B, to START, AND VERIFY on Handswitch 2-HS-30-92A:



Green Light OFF



Red Light ON

[4]

PLACE Handswitch 2-HS-30-80A, CRDM CLR D-B, to START, AND VERIFY on Handswitch 2-HS-30-80A:



Green Light OFF



Red Light ON

[5]

ENSURE the following Lower Compartment Coolers are OFF:



2-CCU-30-75, CNTMT LOWER COMPARTMENT COOLER 2B-B



2-CCU-30-78, CNTMT LOWER COMPARTMENT COOLER 2D-B

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 128 of 164 Data Package: Page ____ of ____

Date ________

6.3.2 Train B CRDM Coolers (2B-B and 2D-B) (continued)

NOTE The following steps will simulate a Train B Phase B Containment Isolation Signal and Phase B signal reset by closing and opening a test switch (TS-2, installed in Step 4.3[13.2])

in SSPS Train B Output Cabinet 2-R-51.

[6]

PLACE Test Switch TS-2 in the CLOSED (ON) position.

[7]

VERIFY the following:

A.

On Handswitch 2-HS-30-92A, CRDM CLR B-B:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

B.

On Handswitch 2-HS-30-80A, CRDM CLR D-B:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

[8]

PLACE Test Switch TS-2 in the OPEN (OFF) position.

[9]

VERIFY the following:

A.

On Handswitch 2-HS-30-92A, CRDM CLR B-B:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

B.

On Handswitch 2-HS-30-80A, CRDM CLR D-B:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

[10]

PLACE the following Transfer Switches in AUX:

A.

2-XS-30-92, CRDM CLR 2B-B FAN 1 & 2 B.

2-XS-30-80, CRDM CLR 2D-B FAN 1 & 2

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 129 of 164 Data Package: Page ____ of ____

Date ________

6.3.2 Train B CRDM Coolers (2B-B and 2D-B) (continued)

[11]

PLACE Test Switch TS-2 in the CLOSED (ON) position.

[12]

VERIFY the following:

A.

On Handswitch 2-HS-30-92C, CRDM CLR 2B-B FAN 1 & 2:



Green Light ON



Red Light OFF B.

On Handswitch 2-HS-30-80C, CRDM CLR 2D-B FAN 1 & 2:



Green Light ON



Red Light OFF

[13]

PLACE Handswitch 2-HS-30-92C, CRDM CLR 2B-B FAN 1 & 2, to CLOSE, AND VERIFY the following on Handswitch 2-HS-30-92C:



Green Light OFF (Acc Crit)



Red Light ON (Acc Crit)

[14]

PLACE Handswitch 2-HS-30-92C, CRDM CLR 2B-B FAN 1 & 2, to TRIP, AND VERIFY the following on Handswitch 2-HS-30-92C:



Green Light ON



Red Light OFF

[15]

PLACE Handswitch 2-HS-30-80C, CRDM CLR 2D-B FAN 1 & 2, to CLOSE, AND VERIFY the following on Handswitch 2-HS-30-80C:



Green Light OFF (Acc Crit)



Red Light ON (Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 130 of 164 Data Package: Page ____ of ____

Date ________

6.3.2 Train B CRDM Coolers (2B-B and 2D-B) (continued)

[16]

PLACE Handswitch 2-HS-30-80C, CRDM CLR 2D-B FAN 1 & 2, to TRIP, AND VERIFY on Handswitch 2-HS-30-80C:



Green Light ON



Red Light OFF

[17]

PLACE Test Switch TS-2 in the OPEN (OFF) position.

[18]

VERIFY the following:

A.

On Handswitch 2-HS-30-92C, CRDM CLR 2B-B FAN 1 & 2:



Green Light ON



Red Light OFF B.

On Handswitch 2-HS-30-80C, CRDM CLR 2D-B FAN 1 & 2:



Green Light ON



Red Light OFF

[19]

PLACE the following Transfer Switches in NORMAL:

A.

2-XS-30-92, CRDM CLR 2B-B FAN 1 & 2 B.

2-XS-30-80, CRDM CLR 2D-B FAN 1 & 2

[20]

PLACE the following Handswitches in STOP PULL TO LOCK:

A.

2-HS-30-92A, CRDM CLR B-B B.

2-HS-30-80A, CRDM CLR D-B

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 131 of 164 Data Package: Page ____ of ____

Date ________

6.4 CRDM Coolers Response To Bus Undervoltage NOTE Subsections 6.4.1 through 6.4.4 may be performed in any order, provided their applicable predecessor Subsection is completed. Unless otherwise noted, the steps within each Subsection shall be performed in the order written. The diagram at the beginning of Section 6.0 may be used as a placekeeping tool throughout the performance of this Section.

6.4.1 CRDM Cooler 2A-A NOTE Subsection 6.4.1 will be starting a stopping CRDM Cooler 2A-A. Ensure personnel and loose equipment are clear of fan discharge and that personnel in the area are cognizant of expected fan start prior to starting a CRDM Cooler.

[1]

ENSURE all prerequisites listed in Section 4.0 for Section 6.4 have been completed.

[2]

ENSURE Subsection 6.2.1 has been completed

[3]

ENSURE Handswitch 2-HS-30-74A, LWR CNTMT CLR A-A, is in STOP PULL TO LOCK.

[4]

PLACE Handswitch 2-HS-30-83A, CRDM CLR A-A, to START, AND VERIFY on Handswitch 2-HS-30-83A:



Green Light OFF



Red Light ON

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 132 of 164 Data Package: Page ____ of ____

Date ________

6.4.1 CRDM Cooler 2A-A (continued)

NOTE The following step will simulate a Loss of Offsite Power.

[5]

MOMENTARILY PLACE a handheld jumper between Terminal Point 7 (wire A17BTP) and Point 8 (wire A17BT1) of Relay 2A1X1, [480V SHUTDOWN BOARD 2A1-A, Compartment 6A]. (Drawing 618F938 AC) 1st CV

[6]

VERIFY on Handswitch 2-HS-30-83A, CRDM CLR A-A:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

NOTE The following step will simulate a restoration of bus voltage.

[7]

MOMENTARILY PLACE a handheld jumper between Terminal Point 3 (wire DCE4) and Point 4 (wire DCE5) of Relay 2A1X1.

(Drawing 618F938 AC) 1st CV

[8]

VERIFY that CRDM Cooler 2A-A remains OFF after approximately 1 minute, as indicated on Handswitch 2-HS-30-83A, CRDM CLR A-A:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

[9]

PLACE Transfer Switch 2-XS-30-83, CRDM CLR 2A-A FAN 1 & 2, in AUX.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 133 of 164 Data Package: Page ____ of ____

Date ________

6.4.1 CRDM Cooler 2A-A (continued)

[10]

PLACE Handswitch 2-HS-30-83C, CRDM CLR 2A-A FAN 1 & 2, to CLOSE, AND VERIFY on Handswitch 2-HS-30-83C:



Green Light OFF



Red Light ON NOTE The following step will simulate a Loss of Offsite Power.

[11]

MOMENTARILY PLACE a handheld jumper between Terminal Point 7 (wire A17BTP) and Point 8 (wire A17BT1) of Relay 2A1X1. (Drawing 618F938 AC) 1st CV

[12]

VERIFY on Handswitch 2-HS-30-83C, CRDM CLR 2A-A FAN 1 & 2:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

NOTE The following step will simulate a restoration of bus voltage.

[13]

MOMENTARILY PLACE a handheld jumper between Terminal Point 3 (wire DCE4) and Point 4 (wire DCE5) of Relay 2A1X1.

(Drawing 618F938 AC) 1st CV

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 134 of 164 Data Package: Page ____ of ____

Date ________

6.4.1 CRDM Cooler 2A-A (continued)

[14]

VERIFY that CRDM Cooler 2A-A STARTS after approximately 1 minute, as indicated on Handswitch 2-HS-30-83C, CRDM CLR 2A-A FAN 1 & 2:



Green Light OFF (Acc Crit)



Red Light ON (Acc Crit)

[15]

PLACE Transfer Switch 2-XS-30-83, CRDM CLR 2A-A FAN 1 & 2, in NORMAL.

[16]

PLACE Handswitch 2-HS-30-83, CRDM CLR A-A, in STOP PULL TO LOCK.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 135 of 164 Data Package: Page ____ of ____

Date ________

6.4.2 CRDM Cooler 2B-B NOTE Subsection 6.4.2 will be starting a stopping CRDM Cooler 2B-B. Ensure personnel and loose equipment are clear of fan discharge and that personnel in the area are cognizant of expected fan start prior to starting a CRDM Cooler.

[1]

ENSURE all prerequisites listed in Section 4.0 for Section 6.4 have been completed.

[2]

ENSURE Subsection 6.2.2 has been completed

[3]

ENSURE Handswitch 2-HS-30-75A, LWR CNTMT CLR B-B, is in STOP PULL TO LOCK.

[4]

PLACE Handswitch 2-HS-30-92A, CRDM CLR B-B, to START, AND VERIFY on Handswitch 2-HS-30-92A:



Green Light OFF



Red Light ON NOTE The following step will simulate a Loss of Offsite Power.

[5]

MOMENTARILY PLACE a handheld jumper between Terminal Point 7 (wire B17CTP) and Point 8 (wire B17CT1) of Relay 2B1X1, [480V SHUTDOWN BOARD 2B1-B, Compartment 6A]. (Drawing 618F941 AC) 1st CV

[6]

VERIFY on Handswitch 2-HS-30-92A, CRDM CLR B-B:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 136 of 164 Data Package: Page ____ of ____

Date ________

6.4.2 CRDM Cooler 2B-B (continued)

NOTE The following step will simulate a restoration of bus voltage.

[7]

MOMENTARILY PLACE a handheld jumper between Terminal Point 3 (wire DCE4) and Point 4 (wire DCE5) of Relay 2B1X1.

(Drawing 618F941 AC) 1st CV

[8]

VERIFY that CRDM Cooler 2B-B remains OFF after approximately 1 minute, as indicated on Handswitch 2-HS-30-92A, CRDM CLR B-B:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

[9]

PLACE Transfer Switch 2-XS-30-92, CRDM CLR 2B-B FAN 1 & 2, in AUX.

[10]

PLACE Handswitch 2-HS-30-92C, CRDM CLR 2B-B FAN 1 & 2, to CLOSE, AND VERIFY on Handswitch 2-HS-30-92C:



Green Light OFF



Red Light ON NOTE The following step will simulate a Loss of Offsite Power.

[11]

MOMENTARILY PLACE a handheld jumper between Terminal Point 7 (wire B17CTP) and Point 8 (wire B17CT1) of Relay 2B1X1. (Drawing 618F941 AC) 1st CV

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 137 of 164 Data Package: Page ____ of ____

Date ________

6.4.2 CRDM Cooler 2B-B (continued)

[12]

VERIFY on Handswitch 2-HS-30-92C, CRDM CLR 2B-B FAN 1 & 2:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

NOTE The following step will simulate a restoration of bus voltage.

[13]

MOMENTARILY PLACE a handheld jumper between Terminal Point 3 (wire DCE4) and Point 4 (wire DCE5) of Relay 2B1X1.

(Drawing 618F941 AC) 1st CV

[14]

VERIFY that CRDM Cooler 2B-B STARTS after approximately 1 minute, as indicated on Handswitch 2-HS-30-92C, CRDM CLR 2B-B FAN 1 & 2:



Green Light OFF (Acc Crit)



Red Light ON (Acc Crit)

[15]

PLACE Transfer Switch 2-XS-30-92, CRDM CLR 2B-B FAN 1 & 2, in NORMAL.

[16]

PLACE Handswitch 2-HS-30-92, CRDM CLR B-B, in STOP PULL TO LOCK.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 138 of 164 Data Package: Page ____ of ____

Date ________

6.4.3 CRDM Cooler 2C-A NOTE Subsection 6.4.3 will be starting a stopping CRDM Cooler 2C-A. Ensure personnel and loose equipment are clear of fan discharge and that personnel in the area are cognizant of expected fan start prior to starting a CRDM Cooler.

[1]

ENSURE all prerequisites listed in Section 4.0 for Section 6.4 have been completed.

[2]

ENSURE Subsection 6.2.3 has been completed

[3]

ENSURE Handswitch 2-HS-30-77A, LWR CNTMT CLR C-A, is in STOP PULL TO LOCK.

[4]

PLACE Handswitch 2-HS-30-88A, CRDM CLR C-A, to START, AND VERIFY on Handswitch 2-HS-30-88A:



Green Light OFF



Red Light ON NOTE The following step will simulate a Loss of Offsite Power.

[5]

MOMENTARILY PLACE a handheld jumper between Terminal Point 7 (wire A27ATP) and Point 8 (wire A27AT1) of Relay 2A2X1, [480V SHUTDOWN BOARD 2A2-A, Compartment 6A]. (Drawing 6947D67 AC) 1st CV

[6]

VERIFY on Handswitch 2-HS-30-88A, CRDM CLR C-A:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 139 of 164 Data Package: Page ____ of ____

Date ________

6.4.3 CRDM Cooler 2C-A (continued)

NOTE The following step will simulate a restoration of bus voltage.

[7]

MOMENTARILY PLACE a handheld jumper between Terminal Point 3 (wire DCE4) and Point 4 (wire DCE5) of Relay 2A2X1.

(Drawing 6947D67 AC) 1st CV

[8]

VERIFY that CRDM Cooler 2C-A remains OFF after approximately 1 minute, as indicated on Handswitch 2-HS-30-88A, CRDM CLR C-A:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

[9]

PLACE Transfer Switch 2-XS-30-88, CRDM CLR 2C-A FAN 1 & 2, in AUX.

[10]

PLACE Handswitch 2-HS-30-88C, CRDM CLR 2C-A FAN 1 & 2, to CLOSE, AND VERIFY on Handswitch 2-HS-30-88C:



Green Light OFF



Red Light ON NOTE The following step will simulate a Loss of Offsite Power.

[11]

MOMENTARILY PLACE a handheld jumper between Terminal Point 7 (wire A27ATP) and Point 8 (wire A27AT1) of Relay 2A2X1. (Drawing 6947D67 AC) 1st CV

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 140 of 164 Data Package: Page ____ of ____

Date ________

6.4.3 CRDM Cooler 2C-A (continued)

[12]

VERIFY on Handswitch 2-HS-30-88C, CRDM CLR 2C-A FAN 1 & 2:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

NOTE The following step will simulate a restoration of bus voltage.

[13]

MOMENTARILY PLACE a handheld jumper between Terminal Point 3 (wire DCE4) and Point 4 (wire DCE5) of Relay 2A2X1.

(Drawing 6947D67 AC) 1st CV

[14]

VERIFY that CRDM Cooler 2C-A STARTS after approximately 1 minute, as indicated on Handswitch 2-HS-30-88C, CRDM CLR 2C-A FAN 1 & 2:



Green Light OFF (Acc Crit)



Red Light ON (Acc Crit)

[15]

PLACE Transfer Switch 2-XS-30-88, CRDM CLR 2C-A FAN 1 & 2, in NORMAL.

[16]

PLACE Handswitch 2-HS-30-88, CRDM CLR C-A, in STOP PULL TO LOCK.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 141 of 164 Data Package: Page ____ of ____

Date ________

6.4.4 CRDM Cooler 2D-B NOTE Subsection 6.4.4 will be starting a stopping CRDM Cooler 2D-B. Ensure personnel and loose equipment are clear of fan discharge and that personnel in the area are cognizant of expected fan start prior to starting a CRDM Cooler.

[1]

ENSURE all prerequisites listed in Section 4.0 for Section 6.4 have been completed.

[2]

ENSURE Subsection 6.2.4 has been completed

[3]

ENSURE Handswitch 2-HS-30-78A, LWR CNTMT CLR D-B, is in STOP PULL TO LOCK.

[4]

PLACE Handswitch 2-HS-30-80A, CRDM CLR D-B, to START, AND VERIFY on Handswitch 2-HS-30-80A:



Green Light OFF



Red Light ON NOTE The following step will simulate a Loss of Offsite Power.

[5]

MOMENTARILY PLACE a handheld jumper between Terminal Point 7 (wire B27BTP) and Point 8 (wire B27BT1) of Relay 2B2X1, [480V SHUTDOWN BOARD 2B2-B, Compartment 6A]. (Drawing 6947D85 AC) 1st CV

[6]

VERIFY on Handswitch 2-HS-30-80A, CRDM CLR D-B:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 142 of 164 Data Package: Page ____ of ____

Date ________

6.4.4 CRDM Cooler 2D-B (continued)

NOTE The following step will simulate a restoration of bus voltage.

[7]

MOMENTARILY PLACE a handheld jumper between Terminal Point 3 (wire DCE4) and Point 4 (wire DCE5) of Relay 2B2X1.

(Drawing 6947D85 AC) 1st CV

[8]

VERIFY that CRDM Cooler 2D-B remains OFF after approximately 1 minute, as indicated on Handswitch 2-HS-30-80A, CRDM CLR D-B:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

[9]

PLACE Transfer Switch 2-XS-30-80, CRDM CLR 2D-B FAN 1 & 2, in AUX.

[10]

PLACE Handswitch 2-HS-30-80C, CRDM CLR 2D-B FAN 1 & 2, to CLOSE, AND VERIFY on Handswitch 2-HS-30-80C:



Green Light OFF



Red Light ON NOTE The following step will simulate a Loss of Offsite Power.

[11]

MOMENTARILY PLACE a handheld jumper between Terminal Point 7 (wire B27BTP) and Point 8 (wire B27BT1) of Relay 2B2X1. (Drawing 6947D85 AC) 1st CV

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 143 of 164 Data Package: Page ____ of ____

Date ________

6.4.4 CRDM Cooler 2D-B (continued)

[12]

VERIFY on Handswitch 2-HS-30-80C, CRDM CLR 2D-B FAN 1 & 2:



Green Light ON (Acc Crit)



Red Light OFF (Acc Crit)

NOTE The following step will simulate a restoration of bus voltage.

[13]

MOMENTARILY PLACE a handheld jumper between Terminal Point 3 (wire DCE4) and Point 4 (wire DCE5) of Relay 2B2X1.

(Drawing 6947D85 AC) 1st CV

[14]

VERIFY that CRDM Cooler 2D-B STARTS after approximately 1 minute, as indicated on Handswitch 2-HS-30-80C, CRDM CLR 2D-B FAN 1 & 2:



Green Light OFF (Acc Crit)



Red Light ON (Acc Crit)

[15]

PLACE Transfer Switch 2-XS-30-80, CRDM CLR 2D-B FAN 1 & 2, in NORMAL.

[16]

PLACE Handswitch 2-HS-30-80, CRDM CLR D-B, in STOP PULL TO LOCK.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 144 of 164 Data Package: Page ____ of ____

Date ________

6.5 CRDM Coolers Auto-Start on Low Air Flow NOTE Subsections 6.5.1 and 6.5.2 may be performed in any order, provided their applicable predecessor Subsections are completed. Unless otherwise noted, the steps within each Subsection shall be performed in the order written. The diagram at the beginning of Section 6.0 may be used as a placekeeping tool throughout the performance of this Section.

6.5.1 CRDM Coolers 2A-A and 2D-B NOTE Subsection 6.5.1 will be starting a stopping CRDM Cooler 2A-A and 2D-B. Ensure personnel and loose equipment are clear of fan discharge and that personnel in the area are cognizant of expected fan start prior to starting a CRDM Cooler.

[1]

ENSURE all prerequisites listed in Section 4.0 for Section 6.5 have been completed.

[2]

ENSURE Subsections 6.3.1, 6.3.2, 6.4.1, and 6.4.4 have been completed.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 145 of 164 Data Package: Page ____ of ____

Date ________

6.5.1 CRDM Coolers 2A-A and 2D-B (continued)

NOTE The following step will enable the CRDM Cooler A-A and D-B Auto-start on Low Flow function.

[3]

LAND the following wires that were lifted in Steps 4.3[14]A and 4.3[14]D:

A.

Wire A17BC3: Point 1 on Terminal Block TA in 2-JB-293-494 [Lwr Cntmt/703 AZ 50]

(Drawing 45W2748-1) 1st CV B.

Wire B27BC3: Point 2 on Terminal Block TA in 2-JB-293-521 [Lwr Cntmt/703 AZ 315]

(Drawing 45W2748-4) 1st CV

[4]

PLACE Handswitch 2-HS-30-80A, CRDM CLR D-B, to START, AND VERIFY on Handswitch 2-HS-30-80A:



Green Light OFF



Red Light ON

[5]

PLACE Handswitch 2-HS-30-83A, CRDM CLR A-A, to A AUTO, AND VERIFY on Handswitch 2-HS-30-83A:



Green Light ON



Red Light OFF

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 146 of 164 Data Package: Page ____ of ____

Date ________

6.5.1 CRDM Coolers 2A-A and 2D-B (continued)

[6]

PLACE the following Transfer Switches in AUX:

A.

2-XS-30-83, CRDM CLR 2A-A FAN 1 & 2 B.

2-XS-30-80, CRDM CLR 2D-B FAN 1 & 2

[7]

PLACE and HOLD Handswitch 2-HS-30-80C, CRDM CLR 2D-B FAN 1 & 2, to TRIP, AND VERIFY on Handswitch 2-HS-30-80C:



Green Light ON



Red Light OFF

[8]

VERIFY that CRDM Cooler 2A-A STARTS as indicated on Handswitch 2-HS-30-83C, CRDM CLR 2A-A FAN 1 & 2:



Green Light OFF (Acc Crit)



Red Light ON (Acc Crit)

[9]

RELEASE Handswitch 2-HS-30-80C, CRDM CLR 2D-B FAN 1 & 2.

[10]

PLACE and HOLD Handswitch 2-HS-30-83C, CRDM CLR 2A-A FAN 1 & 2, to TRIP, AND VERIFY on Handswitch 2-HS-30-83C:



Green Light ON



Red Light OFF

[11]

VERIFY that CRDM Cooler 2D-B STARTS as indicated on Handswitch 2-HS-30-80C, CRDM CLR 2D-B FAN 1 & 2:



Green Light OFF (Acc Crit)



Red Light ON (Acc Crit)

[12]

RELEASE Handswitch 2-HS-30-83C, CRDM CLR 2A-A FAN 1 & 2.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 147 of 164 Data Package: Page ____ of ____

Date ________

6.5.1 CRDM Coolers 2A-A and 2D-B (continued)

[13]

PLACE the following Transfer Switches in NORMAL:

A.

2-XS-30-83, CRDM CLR 2A-A FAN 1 & 2 B.

2-XS-30-80, CRDM CLR 2D-B FAN 1 & 2

[14]

PLACE the following Handswitches in STOP PULL TO LOCK:

A.

2-HS-30-83A, CRDM CLR A-A B.

2-HS-30-80A, CRDM CLR D-B

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 148 of 164 Data Package: Page ____ of ____

Date ________

6.5.2 CRDM Coolers 2B-B and 2C-A NOTE Subsection 6.5.2 will be starting a stopping CRDM Cooler 2B-B and 2C-A. Ensure personnel and loose equipment are clear of fan discharge and that personnel in the area are cognizant of expected fan start prior to starting a CRDM Cooler.

[1]

ENSURE all prerequisites listed in Section 4.0 for Section 6.5 have been completed.

[2]

ENSURE Subsections 6.3.1, 6.3.2, 6.4.2, and 6.4.3 have been completed.

NOTE The following step will enable the CRDM Cooler B-B and C-A Auto-start on Low Flow function.

[3]

LAND the following wires that were lifted in Steps 4.3[14]B and 4.3[14]C:

A.

Wire B17CC3: Point 2 on Terminal Block TA in 2-JB-293-517 [Lwr Cntmt/703 AZ 135]

(Drawing 45W2748-3) 1st CV B.

Wire A27AC3: Point 2 on Terminal Block TA in 2-JB-293-519 [Lwr Cntmt/703 AZ 221]

(Drawing 45W2748-2) 1st CV

[4]

PLACE Handswitch 2-HS-30-88A, CRDM CLR C-A, to START, AND VERIFY on Handswitch 2-HS-30-88A:



Green Light OFF



Red Light ON

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 149 of 164 Data Package: Page ____ of ____

Date ________

6.5.2 CRDM Coolers 2B-B and 2C-A (continued)

[5]

PLACE Handswitch 2-HS-30-92A, CRDM CLR B-B, to A AUTO, AND VERIFY on Handswitch 2-HS-30-92A:



Green Light ON



Red Light OFF

[6]

PLACE the following Transfer Switches in AUX:

A.

2-XS-30-92, CRDM CLR 2B-B FAN 1 & 2 B.

2-XS-30-88, CRDM CLR 2C-A FAN 1 & 2

[7]

PLACE and HOLD Handswitch 2-HS-30-88C, CRDM CLR 2C-A FAN 1 & 2, to TRIP, AND VERIFY on Handswitch 2-HS-30-88C:



Green Light ON



Red Light OFF

[8]

VERIFY that CRDM Cooler 2B-B STARTS as indicated on Handswitch 2-HS-30-92C, CRDM CLR 2B-B FAN 1 & 2:



Green Light OFF (Acc Crit)



Red Light ON (Acc Crit)

[9]

RELEASE Handswitch 2-HS-30-88C, CRDM CLR 2C-A FAN 1 & 2.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 150 of 164 Data Package: Page ____ of ____

Date ________

6.5.2 CRDM Coolers 2B-B and 2C-A (continued)

[10]

PLACE and HOLD Handswitch 2-HS-30-92C, CRDM CLR 2B-B FAN 1 & 2, to TRIP, AND VERIFY on Handswitch 2-HS-30-92C:



Green Light ON



Red Light OFF

[11]

VERIFY that CRDM Cooler 2C-A STARTS as indicated on Handswitch 2-HS-30-88C, CRDM CLR 2C-A FAN 1 & 2:



Green Light OFF (Acc Crit)



Red Light ON (Acc Crit)

[12]

RELEASE Handswitch 2-HS-30-92C, CRDM CLR 2B-B FAN 1 & 2.

[13]

PLACE the following Transfer Switches in NORMAL:

A.

2-XS-30-92, CRDM CLR 2B-B FAN 1 & 2 B.

2-XS-30-88, CRDM CLR 2C-A FAN 1 & 2

[14]

PLACE the following Handswitches in STOP PULL TO LOCK:

A.

2-HS-30-92A, CRDM CLR B-B B.

2-HS-30-88A, CRDM CLR C-A

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 151 of 164 Data Package: Page ____ of ____

Date ________

6.6 CRDM Coolers Air Flow

[1]

ENSURE all prerequisites listed in Section 4.0 for Section 6.6 have been completed

[2]

ENSURE air flow measurements for the CRDM Coolers have been performed using GTM-05, HVAC Air Balance:

A.

2-CLR-30-83, CRDM COOLER 2A-A B.

2-CLR-30-92, CRDM COOLER 2B-B C.

2-CLR-30-88, CRDM COOLER 2C-A D.

2-CLR-30-80, CRDM COOLER 2D-B

[3]

ENSURE completed GTM-05 data sheets are attached to this instruction.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 152 of 164 Data Package: Page ____ of ____

Date ________

6.6 CRDM Coolers Air Flow (continued)

NOTE The remaining steps in Section 6.6 record and verify data from the completed GTM-05, HVAC Air Balance Package for system 30I and may be completed in any order unless otherwise specified.

[4]

RECORD the air flow measurement for Cooler 2-CLR-30-83, CRDM COOLER 2A-A, aligned to Shroud Suction below, AND VERIFY it meets acceptance criteria.

CFM Acc Crit: 21,500 CFM minimum

[5]

RECORD the air flow measurement for Cooler 2-CLR-30-92, CRDM COOLER 2B-B, aligned to Shroud Suction below, AND VERIFY it meets acceptance criteria.

CFM Acc Crit: 21,500 CFM minimum

[6]

RECORD the air flow measurement for Cooler 2-CLR-30-88, CRDM COOLER 2C-A, aligned to Shroud Suction below, AND VERIFY it meets acceptance criteria.

CFM Acc Crit: 21,500 CFM minimum

[7]

RECORD the air flow measurement for Cooler 2-CLR-30-80, CRDM COOLER 2D-B, aligned to Shroud Suction below, AND VERIFY it meets acceptance criteria.

CFM Acc Crit: 21,500 CFM minimum

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 153 of 164 Data Package: Page ____ of ____

Date ________

7.0 POST PERFORMANCE ACTIVITY

[1]

ENSURE Sections 6.1 through 6.6 have been completed.

[2]

REMOVE the switched jumpers installed in step 4.3[13] from the following locations:

[2.1]

Labeled TS-1:

In SSPS Train-A Output Cabinet 2-R-48, at TB615, between Pt. 11 (Wire 2340VL) and Pt. 12 (Wire CNA1).

(Drawing 45N2676-4) 1st CV

[2.2]

Labeled TS-2:

In SSPS Train-B Output Cabinet 2-R-51, at TB615, between Pt. 11 (Wire 2435VL) and Pt. 12 (Wire CNB1).

(Drawing 45N2677-4) 1st CV

[3]

ENSURE any temporary conditions recorded in Appendix B, Temporary Condition Log, are addressed for necessary restoration as applicable (N/A if no conditions recorded).

[4]

NOTIFY the Unit 2 US/SRO/SM of the test completion and system alignment.

[5]

NOTIFY the Unit 1 US/SRO/SM of the test completion and system alignment.

8.0 RECORDS A.

QA Records Completed Test Package.

B.

Non-QA Records None

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 154 of 164 Appendix A (Page 1 of 1)

TEST PROCEDURES/INSTRUCTIONS REFERENCE REVIEW Data Package: Page ____ of ____

Date ________

NOTES

1)

Additional copies of this table may be made as necessary.

2)

Initial and date indicates review has been completed for impact.

PROCEDURE/

INSTRUCTION REVISION/CHANGES IMPACT Yes/No INITIAL AND DATE.

(N/A for no change)

GTM-05 FSAR Section 9.2.1 Section 9.4.7 Table 14.2-1, Sh 4 & 5 Table 14.2-1, Sh 38 & 39 WBN2-30RB-4002 G-37 2-TSD-30I-1 2-PTI-030L-01 2-PTI-067-02-A 2-PTI-067-02-B 2-PTI-067-03 MI-57.002 SSD-2-LPT-67-85 SSD-2-LPT-67-101 SSD-2-LPT-67-93 SSD-2-LPT-67-109 VM-F180-3066

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 155 of 164 Appendix B (Page 1 of 1)

TEMPORARY CONDITION LOG Data Package: Page ____ of ____

Date ________

NOTES

1)

Additional copies of this table may be made as necessary.

2)

These steps will be N/Ad if no temporary condition existed.

ITEM No.

TEMPORARY CONDITION DESCRIPTION PERFORMED RETURNED TO NORMAL Step No.

Performed By/Date CV By/Date Step No.

Returned By/Date CV By/Date

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 156 of 164 Appendix C (Page 1 of 2)

PERMANENT PLANT INSTRUMENTATION LOG Data Package: Page ____ of ____

Date ________

INSTRUMENT OR INSTRUMENT LOOP #

CAL DUE DATE FILLED AND VENTED1 PLACED IN SERVICE1 USED FOR QUANTITATIVE ACC CRIT POST-TEST CAL DATE2 POST-TEST CALIBRATION ACCEPTABLE2 INITIAL/DATE INIT/DATE INIT/DATE YES NO 2-TE-30-211A N/A NO N/A N/A 2-TE-30-211B N/A NO N/A N/A 2-TE-30-211C N/A NO N/A N/A 2-TE-30-211D N/A NO N/A N/A 2-TE-30-211E N/A NO N/A N/A 2-TE-30-211F N/A NO N/A N/A 2-FS-30-80A/B N/A NO N/A N/A 2-FS-30-83A/B N/A NO N/A N/A 2-FS-30-88A/B N/A NO N/A N/A 2-FS-30-92A/B N/A NO N/A N/A

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 157 of 164 Appendix C (Page 2 of 2)

PERMANENT PLANT INSTRUMENTATION LOG Data Package: Page ____ of ____

Date ________

INSTRUMENT OR INSTRUMENT LOOP #

CAL DUE DATE FILLED AND VENTED1 PLACED IN SERVICE1 USED FOR QUANTITATIVE ACC CRIT POST-TEST CAL DATE2 POST-TEST CALIBRATION ACCEPTABLE2 INITIAL/DATE INIT/DATE INIT/DATE YES NO 2-LPT-67-85 N/A NO N/A N/A 2-LPT-67-93 N/A NO N/A N/A 2-LPT-67-101 N/A NO N/A N/A 2-LPT-67-109 N/A NO N/A N/A 1

These items may be initialed and dated by personnel performing the task. Instrumentation not required to be filled and vented may be identified as Not Applicable. (N/A) 2 May be identified as Not Applicable (N/A) if instrument was not used to verify/record quantitative acceptance criteria data.

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 158 of 164 Appendix D (Page 1 of 3)

SWITCH LINEUP Data Package: Page ____ of ____

Date ________

IDENTIFICATION LOCATION NOMENCLATURE POSITION VERIFIED BY:

INITIAL Main Control Room 2-HS-30-83A 2-M-9 CRDM CLR A-A STOP PULL TO LOCK 2-HS-30-92A 2-M-9 CRDM CLR B-B STOP PULL TO LOCK 2-HS-30-88A 2-M-9 CRDM CLR C-A STOP PULL TO LOCK 2-HS-30-80A 2-M-9 CRDM CLR D-B STOP PULL TO LOCK 2-HS-67-85A 0-M-27A CRDM CLR A OUTLET TCV P AUTO 2-HS-67-93A 0-M-27A CRDM CLR C OUTLET TCV P AUTO 2-HS-67-101A 0-M-27A CRDM CLR B OUTLET TCV P AUTO 2-HS-67-109A 0-M-27A CRDM CLR D OUTLET TCV P AUTO Auxiliary Control Room 2-HS-30-84C 2-L-10 CRDM CLR A-A SHROUD SUCTION CLOSE 2-HS-30-85C 2-L-10 CRDM CLR A-A LWR CNTMT SUCT OPEN 2-HS-30-93C 2-L-10 CRDM CLR B-B SHROUD SUCTION CLOSE 2-HS-30-94C 2-L-10 CRDM CLR B-B LWR CNTMT SUCT OPEN 2-HS-30-89C 2-L-10 CRDM CLR C-A SHROUD SUCTION CLOSE 2-HS-30-90C 2-L-10 CRDM CLR C-A LWR CNTMT SUCT OPEN 2-HS-30-81C 2-L-10 CRDM CLR D-B SHROUD SUCTION CLOSE 2-HS-30-82C 2-L-10 CRDM CLR B-B LWR CNTMT SUCT OPEN 2-HS-67-85C 2-L-10 CRDM COOLER A-A ERCW OUTLET TCV P AUTO 2-HS-67-93C 2-L-10 CRDM COOLER C-A ERCW OUTLET TCV P AUTO 2-HS-67-101C 2-L-10 CRDM COOLER B-B ERCW OUTLET TCV P AUTO 2-HS-67-109C 2-L-10 CRDM COOLER D-B ERCW OUTLET TCV P AUTO

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 159 of 164 Appendix D (Page 2 of 3)

SWITCH LINEUP Data Package: Page ____ of ____

Date ________

2-L-11A 2-XS-30-90 2-L-11A CRDM COOLER C-A LWR CNTMT SUCT DMPR NOR 2-XS-30-84 2-L-11A CRDM COOLER A-A SHROUD SUCT DMPR NOR 2-XS-30-85 2-L-11A CRDM COOLER A-A LWR CNTMT SUCT DMPR NOR 2-XS-30-89 2-L-11A CRDM COOLER C-A SHROUD SUCT DMPR NOR 2-XS-67-85 2-L-11A CRDM CLR A-A ERCW OUTLET TCV NOR 2-XS-67-93 2-L-11A CRDM CLR C-A OUTLET TCV NOR 2-L-11B 2-XS-30-81 2-L-11B CRDM CLR D-B SHROUD SUCT DMPR NOR 2-XS-30-82 2-L-11B CRDM CLR D-B LWR CNTMT SUCT DMPR NOR 2-XS-30-93 2-L-11B CRDM CLR B-B SHROUD SUCT DMPR NOR 2-XS-30-94 2-L-11B CRDM CLR B-B LWR CNTMT SUCT DMPR NOR 2-XS-67-101 2-L-11B CRDM CLR B-B ERCW OUTLET TCV NOR 2-XS-67-109 2-L-11B CRDM CLR D-B ERCW OUTLET TCV NOR

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 160 of 164 Appendix D (Page 3 of 3)

SWITCH LINEUP Data Package: Page ____ of ____

Date ________

IDENTIFICATION LOCATION NOMENCLATURE POSITION VERIFIED BY:

INITIAL 480V Shutdown Board Room 2A 2-HS-30-83C 480V SHUTDOWN BOARD 2A1-A, Compartment 5A CRDM CLR 2A-A FAN 1 & 2 AUTO 2-XS-30-83 480V SHUTDOWN BOARD 2A1-A, Compartment 5A CRDM CLR 2A-A FAN 1 & 2 NORMAL 2-HS-30-88C 480V SHUTDOWN BOARD 2A2-A, Compartment 5A CRDM CLR 2C-A FAN 1 & 2 AUTO 2-XS-30-88 480V SHUTDOWN BOARD 2A2-A, Compartment 5A CRDM CLR 2C-A FAN 1 & 2 NORMAL 480V Shutdown Board Room 2B 2-HS-30-92C 480V SHUTDOWN BOARD 2B1-B, Compartment 5A CRDM CLR 2B-B FAN 1 & 2 AUTO 2-XS-30-92 480V SHUTDOWN BOARD 2B1-B, Compartment 5A CRDM CLR 2B-B FAN 1 & 2 NORMAL 2-HS-30-80C 480V SHUTDOWN BOARD 2B2-B, Compartment 5A CRDM CLR 2D-B FAN 1 & 2 AUTO 2-XS-30-80 480V SHUTDOWN BOARD 2B2-B, Compartment 5A CRDM CLR 2D-B FAN 1 & 2 NORMAL

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 161 of 164 Appendix E (Page 1 of 4)

POWER LINEUP Data Package: Page ____ of ____

Date ________

IDENTIFICATION LOCATION NOMENCLATURE POSITION VERIFIED BY:

INITIAL 480V Shutdown Board Room 2A 2-BKR-30-83 480V SHUTDOWN BOARD 2A1-A, Compartment 7B CRDM CLR 2A-A (2-CLR-30-83)

DISCONNECTED 2-BKR-30-88 480V SHUTDOWN BOARD 2A2-A, Compartment 7A CRDM CLR 2C-A (2-CLR-30-88)

DISCONNECTED 480V Shutdown Board Room 2B 2-BKR-30-92 480V SHUTDOWN BOARD 2B1-B, Compartment 7C CRDM CLR 2B-B (2-CLR-30-92)

DISCONNECTED 2-BKR-30-80 480V SHUTDOWN BOARD 2B2-B, Compartment 7B CRDM CLR 2D-B (2-CLR-30-80)

DISCONNECTED

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 162 of 164 Appendix E (Page 2 of 4)

POWER LINEUP Data Package: Page ____ of ____

Date ________

IDENTIFICATION LOCATION NOMENCLATURE POSITION VERIFIED BY:

INITIAL Vital Battery Board Room I 2-BKR-235-1/7 120V AC VITAL INSTR POWR BOARD 2-I BKR 7 AUX RELAY RACK 2-R-76 BUS A ON 2-BKR-235-1/8 120V AC VITAL INSTR POWR BOARD 2-I BKR 8 AUX RELAY RACK C BUS TO PNL 2-R-76 ON 2-BKR-235-1/11 120V AC VITAL INSTR POWR BOARD 2-I BKR 11 AUX RELAY RACK A BUS TO PNL 2-R-75 ON Vital Battery Board Room III 0-FU-236-3/A42 125V DC BATT BD III CKT A42 CRD COOLING UNIT 2A-A SUCTION DMP INSTALLED*

0-FU-236-3/A43 125V DC BATT BD III CKT A43 CRD COOLING UNIT 2A-A RM DIVERSION DMP INSTALLED*

0-FU-236-3/A44 125V DC BATT BD III CKT A44 CRD COOLING UNIT 2C-A SUCTION DMP INSTALLED*

0-FU-236-3/A45 125V DC BATT BD III CKT A45 CRD COOLING UNIT 2C-A RM DIVERSION DMP INSTALLED*

0-FU-236-3/B42 125V DC BATT BD III CKT B42 CRD COOLING UNIT 2A-A SUCTION DMP INSTALLED*

0-FU-236-3/B43 125V DC BATT BD III CKT B43 CRD COOLING UNIT 2A-A RM DIVERSION DMP INSTALLED*

0-FU-236-3/B44 125V DC BATT BD III CKT B44 CRD COOLING UNIT 2C-A SUCTION DMP INSTALLED*

0-FU-236-3/B45 125V DC BATT BD III CKT B45 CRD COOLING UNIT 2C-A RM DIVERSION DMP INSTALLED*

0-FU-236-3/A22 125V DC BATT BD III CKT A22 CONTROL ROD DRIVE VENT CLR A SUPPLY VALVE INSTALLED*

0-FU-236-3/A24 125V DC BATT BD III CKT A24 CONTROL ROD DRIVE VENT CLR C SUPPLY VALVE INSTALLED*

2-BKR-235-3/26 120V AC VITAL INSTR POWR BOARD 2-III BKR 26 BOP INST RACK 1-R-141 1-R-144/146/147 BUS C ON 2-BKR-235-3/40 120V AC VITAL INSTR POWR BOARD 2-III BKR 40 AUX RELAY RACK SSPS AUX RELAYS ON

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 163 of 164 Appendix E (Page 3 of 4)

POWER LINEUP Data Package: Page ____ of ____

Date ________

IDENTIFICATION LOCATION NOMENCLATURE POSITION VERIFIED BY:

INITIAL Vital Battery Board Room II 2-BKR-235-2/6 120V AC VITAL INSTR POWR BOARD 2-II BKR 6 AUX RELAY RACK 2-R-76 BUS B ON 2-BKR-235-2/9 120V AC VITAL INSTR POWR BOARD 2-II BKR 9 AUX RELAY RACK B BUS TO PNL 2-R-75 ON Vital Battery Board Room IV 0-FU-236-4/A13 125V DC BATT BD IV CKT A13 CRD COOLING UNIT 2D-B SUCTION DMP INSTALLED*

0-FU-236-4/A14 125V DC BATT BD IV CKT A14 CRD COOLING UNIT 2D-B RM DIVERSION DMP INSTALLED*

0-FU-236-4/A15 125V DC BATT BD IV CKT A15 CRD COOLING UNIT 2B-B SUCTION DMP INSTALLED*

0-FU-236-4/A16 125V DC BATT BD IV CKT A16 CRD COOLING UNIT 2B-B RM DIVERSION DMP INSTALLED*

0-FU-236-4/B13 125V DC BATT BD IV CKT B13 CRD COOLING UNIT 2D-B SUCTION DMP INSTALLED*

0-FU-236-4/B14 125V DC BATT BD IV CKT B14 CRD COOLING UNIT 2D-B RM DIVERSION DMP INSTALLED*

0-FU-236-4/B15 125V DC BATT BD IV CKT B15 CRD COOLING UNIT 2B-B SUCTION DMP INSTALLED*

0-FU-236-4/B16 125V DC BATT BD IV CKT B16 CRD COOLING UNIT 2B-B RM DIVERSION DMP INSTALLED*

0-FU-236-4/A10 125V DC BATT BD IV CKT A10 CONTROL ROD DRIVE VENT CLR B SUPPLY VALVE INSTALLED*

0-FU-236-4/A12 125V DC BATT BD IV CKT A12 CONTROL ROD DRIVE VENT CLR D SUPPLY VALVE INSTALLED*

2-BKR-235-4/26 120V AC VITAL INSTR POWR BOARD 2-IV BKR 26 AUX BLD INSTR BUS B TO PNL 2-L-26 ON 2-BKR-235-4/35 120V AC VITAL INSTR POWR BOARD 2-IV BKR 35 AUX RELAY RACK SSPS AUX RELAYS ON

WBN Unit 2 Control Rod Drive Mechanism Coolers 2-PTI-030I-01 Rev. 0000 Page 164 of 164 Appendix E (Page 4 of 4)

POWER LINEUP Data Package: Page ____ of ____

Date ________

IDENTIFICATION LOCATION NOMENCLATURE POSITION VERIFIED BY:

INITIAL Unit 2 Auxiliary Instrument Room 2-FU-275-R75/K1 2-FU-275-R75/K2 2-R-75 Row K, Fuse 1 & 2 CRDM CLR UNIT 2B-B ANN SEP RELAY INSTALLED*

2-FU-275-R75/K19 2-FU-275-R75/K20 2-R-75 Row K, Fuse 19 & 20 CRDM CLR UNIT 2A-A ANN SEP RELAY INSTALLED*

2-FU-275-R75/K21 2-FU-275-R75/K22 2-R-75 Row K, Fuse 21 & 22 CRDM CLR UNIT 2C-A ANN SEP RELAY INSTALLED*

2-FU-275-R75/L3 2-FU-275-R75/L4 2-R-75 Row L, Fuse 3 & 4 CRDM CLR UNIT 2C-A ANN SEP RELAY INSTALLED*

2-FU-275-R75/L5 2-FU-275-R75/L6 2-R-75 Row L, Fuse 5 & 6 CRDM CLR UNIT 2A-A ANN SEP RELAY INSTALLED*

2-FU-275-R75/L11 2-FU-275-R75/L12 2-R-75 Row L, Fuse 11 & 12 CRDM CLR UNIT 2D-B ANN SEP RELAY INSTALLED*

2-FU-275-R75/L15 2-FU-275-R75/L16 2-R-75 Row L, Fuse 15 & 16 CRDM CLR UNIT 2B-B ANN SEP RELAY INSTALLED*

2-FU-275-R75/L17 2-FU-275-R75/L18 2-R-75 Row L, Fuse 17 & 18 CRDM CLR UNIT 2D-B ANN SEP RELAY INSTALLED*

2-FU-275-R76/I9 2-FU-275-R76/I10 2-R-76 Row I, Fuse 9 & 10 PANEL 2-M-9 MOTOR TRIPOUT ANNUNCIATION SEPARATION RELAY INSTALLED*

2-FU-275-R76/I13 2-FU-275-R76/I14 2-R-76 Row I, Fuse 13 & 14 PANEL 2-M-9 MOTOR TRIPOUT ANNUNCIATION SEPARATION RELAY INSTALLED*

2-FU-275-R76/N1 2-FU-275-R76/N2 2-R-76 Row N, Fuse 1 & 2 MOTOR TRIPOUT BUZZER FOR PANELS M-1 THROUGH M-6 AND M-9 INSTALLED*

  • When installing fuses with actuators, ensure that the actuating rod is oriented correctly to provide for proper alarm initiation and visual indication.