Text
a I-(ZAA&
r)1 E TENNESSEVALLEY AUTHORITY CHATTANOOGA. TENNESSEE 37401 830 Power Building Ui -1 7
Mr. James P. O'Reilly, Director Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Region II -
Suite 3100 101 Marietta Street Atlanta, Georgia 30303 4
Dear Mr. O'Reilly:
BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 - PURCHASE REQUESTS WITHOUT IEEE QUALIFICATIONS SPECIFIED - NCR BNP THIRD INTERIM REPORT The subject condition was initially reported to NRC-OE Inspector L. E. Foster on November 25, 1977.
Interim reports were submitted on December 15, 1977, and June 30, 1978. Enclosed is our third interim report. We expect to submit our next written report by March 8, 1979.
If you have any questions regarding this matter, please get in touch with M. R. Wisenburg at FTS 854-2581.
Very truly yours,
--I.
E. Gillelnd Assistant Manager of Power Enclosure cc:
Mr. John G. Davis, Acting Director (Enclosure)
Office of Inspection and Enforcement U.S. Nuclear Regulatory Commission Washington, DC 20555 jA3 ze>-
k e )Q p
ENCLOSURE BELLEFONTE NUCLEAR PLANT UNITS 1 AND 2 PURCHASE REQUESTS ISSUED WITHOUT IEEE QUALIFICATIONS SPECIFIED NCR BNP-7 THIRD INTERIM REPORT Interim Progress Affected procurement requests for process flow equipment have been revised and sent to the respective vendors for assurance that the equipment does meet IEEE Class IE standards.
TVA is continuing its investigation into the qualification of HVAC equipment that has been affected by this nonconformance. TVA will propose a corrective action upon receipt of this information.