ML111010421

From kanterella
Jump to navigation Jump to search

Written Retake - NRC Comments on Draft Licensee-Developed Exam (Written Tests)(Folder 2)
ML111010421
Person / Time
Site: Ginna 
Issue date: 12/13/2010
From: David Silk
Operations Branch I
To:
Constellation Energy Nuclear Group
Hansell S
Shared Package
ML103200302 List:
References
TAC U01838
Download: ML111010421 (7)


Text

ES-401 GINNA Written Examination Review Worksheet Form ES-401-9

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q#

LOK LOD (F/H) (1-5)

Stem Cues T/F Credo Partial Job-Minutia

  1. /

Back-Q=

SRO B/M/N U/E/S Explanation Focus Dis!.

Link units ward KIA Only 1

H 2

X B

E "current power supply" vs "effect on the power supply" 2

F 2

X N

E F vs H. Capitalize DIRECT.

3 F

3 M

S 4

F 3

N S

5 H

2 M

S 6

H 3

X N

E Adjust distracters to eliminate "same" as a clue.

7 F

2 X

N E

Make clear that PRT temp alarm actuated. C/O add "directly."

8 F

2 X

B U

KA mismatch. Fix Q or reselected KA.

Instructions

[Refer to Section 0 of ES-401 and Appendix B for additional information regarding each of the following concepts.]

1.

Enter the level of knowledge (LOK) of each question as either (F}undamental or (H}igher cognitive level.

2.

Enter the level of difficulty (LOD) of each question using a 1 - 5 (easy - difficult) rating scale (questions in the 2 - 4 range are acceptable).

3.

Check the appropriate box if a psychometric flaw is identified:

The stem lacks sufficient focus to elicit the correct answer (e.g., unclear intent, more information is needed, or too much needless information).

The stem or distractors contain cues (i.e., clues, specific determiners, phrasing, length, etc).

The answer choices are a collection of unrelated true/false statements.

The distractors are not credible; single implausible distractors should be repaired, more than one is unacceptable.

One or more distractors is (are) partially correct (e.g., if the applicant can make unstated assumptions that are not contradicted by stem).

4.

Check the appropriate box if a job content error is identified:

The question is not linked to the job requirements (i.e., the question has a valid KIA but, as written, is not operational in content).

The question requires the recall of knowledge that is too specific for the closed reference test mode (i.e., it is not required to be known from memory).

The question contains data with an unrealistic level of accuracy or inconsistent units (e.g., panel meter in percent with question in gallons).

The question requires reverse logic or application compared to the job requirements.

5.

Check questions that are sampled for conformance with the approved KIA and those that are designated SRO-only (KIA and license level mismatches are unacceptable).

6.

Enter question source: (B}ank, (M}odified, or (N}ew. Check that (M}odified questions meet criteria of ES-401 Section D.2.f.

7.

Based on the reviewer's judgment, is the question as written (U}nsatisfactory (requiring repair or replacement), in need of (E}ditorial enhancement, or (S}atisfactory?

8.

At a minimum, explain any "U" ratings (e.g., how the Appendix B psychometric attributes are not being met).

ES-401 2

Form ES-401-9

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q#

LOK LOD (F/H)

(1-5)

Stem Cues T/F Credo Partial Job-Minutia

  1. /

Back-Q=

SRO B/M/N UlE/S Explanation Focus Dist.

Link units ward KIA Only 9

H 2

X M

E Change C/D to 45 vs 40 minutes.

10 H

3 B

S 11 H

4 B

S 12 H

3 B

S 13 F

2 X

D N

E Ask for maximum flow. Make D 400 to be more plausible.

14 F

2 B

S 15 H

2 N

S 16 H

3 X

N E

PI-2161 is on loop B not A.

17 H

2 M

S 18 H

2 M

S 19 F

2 N

S 20 F

2 B

S 21 F

2 N

S 22 F

2 B

S 23 H

3 X

N E

Fix wording in B, spell out 1 in A &B.

24 H

1 X

B U

LOD 1. Reselect or rewrite Q.

25 H

2 B

S 26 H

3 N

S Typo in KA statement 27 H

2 X

X B

U No correct answer. Proportional heaters off @ 2250.

28 F

2 N

S

ES-401 3

Form ES-401-9

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

0#

LOK LOD (F/H)

(1-5)

Stem Cues T/F Credo Partial Job-Minutia

  1. 1 Back-Q=

SRO B/M/N UtEIS Explanation Focus Dis!.

Link units ward KIA Only 29 H

2 B

S Fix explanation for C.

30 H

3 N

S 31 H

2 N

S


~

..~

.. -------~"

32 H

2 N

S 33 F

2 C,D N

U Red lights indicate open not plausible. Eliminate colors from Q.

34 H

2 B

S 35 F

2 N

S 36 H

3 N

S 37 H

3 B,D N

U Minimum temp for criticality is not plausible.

38 F

2 N

S 39 F

2 B

S 40 H

3 D

A B

U Too academic Licensee to change Q or reselect.

41 F

3 B

S 42 F

2 X

B U

KIA mismatch. Procedure vs system features. Fix or reselect.

43 F

2 X

N E

Typo following. Fvs H 44 H

2 B

S 45 H

2 X

B E

Reword Q wrt IA leak location and impact.

46 H

3 A

B E

Include a procedure in A to parallel other distracters.

47 H

3 B

S 48 H

2 B

S

4. Job Content Flaws
5. Other
6.
8.

Q# I (~~~ I~1~~ IStemlcu~sh/FI JOb-I Minutia, #1,Back-, Q= I SRO I B/MIN Explanation Focus Link units ward KIA Only 4

Form ES-401*9

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q#

LOK LOD (F/H)

(1-5)

Stem Cues T/F Credo Partial Job-Minutia

  1. 1 Back-Q=

SRO B/M/N U/E/S Explanation Focus Dis!.

Link units ward KIA Only 49 H

2 M

S 50 H

2 N

S H vs F 51 H

2 C,D N

U Change pressures in C &D to make plausible.

52 F

3 N

S 53 F

2 N

S FvsH 54 H

3 X

N E

Delete "may." Use "can" or something more definitive.

55 F

4 B

S 56 H

2 N

S 57 H

2 B

S 58 H

3 N

S 59 F

2 N

S 60 H

3 B

S 61 H

2 B

S 62 F

3 B

S 63 H

3 N

S H vs F 64 H

2 B

S

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q#

LOK LOD (F/H)

(1-5)

Stem Cues TIF Credo Partial Job-Minutia

  1. 1 Back-Q=

SRO B/M/N UtEIS Explanation Focus Dis!.

Link units ward KIA Only 65 F

2 N

S 66 H

2 M

S H vs F 67 H

2 B

S Q?,8 F

1 N

U Too obvious. Fix or reselect KIA.

ES-401 5

Form ES-401-9

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q#

LOK LOD (F/H) (1-5)

Stem Cues T/F Credo Partial Job-Minutia

  1. 1 Back-Q=

SRO B/M/N UtE/S Explanation Focus Dis!.

Link units ward KIA Only 69 F

3 N

S 70 H

2 M

S 71 F

2 A,C,D B

U B is the obvious. Fix Q or replace.

72 F

3 X

N E

Spell out 1.

73 F

3 X

N U

Does not meets intent of KIA. GET Q. Fix or reselect KIA.

74 F

2 M

S 75 H

2 D

B S

H vs F 76 H

2 X

B E

Separate & combine 1 51 2 bullets.

77 H

2 N

S 78 H

3 C,D N

U Reference makes C/O implausible. Make PZR level 0 with no ref.

79 H

3 N

S

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

0#

LOK LOD (F/H)

(1-5) 8tem Cues T/F Cred. Partial Job-Minutia

  1. 1 Back 0= SRO B/M/N U/E/S Explanation Focus Dist.

Link units ward KIA Only 80 H

3 X

N E

C - delete last sentence, add no SID required to ensure correctness.

81 H

2 N

8 82 H

2 X

B E

Typo - remove gap in bullet list.

83 H

3 X

N E

Typo in 0 identifies vs identified. Edit distracters.

84 H

2 B

S 85 H

2 D

M E

No UD while continuing operations not plausible. Add excess UD.

86 H

3 N

8 ES-401 6

Form ES-401-9

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

0#

LOK LOD (F/H)

(1-5)

Stem Cues T/F Credo Partial Job-Minutia

  1. 1 Back-0= 8RO B/M/N U/EIS Explanation Focus Dist.

Link units ward KIA Only 87 H

2 X

M E

PI-2161 is Loop B. Delete PTL for EDGs in A &D. Edit D.

88 H

3 X

N E

Typo - effect vs affect 89 H

2 B

S 90 H

2 X

M E

Fix one minute delays in distracters.

91 H

2 N

S 92 F

2 X

N E

Include data in a to specify plant is in Mode 6.

93 H

2 N

S 94 F

3 N

S 95 H

3 N

8

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

0#

LOK LOD (F/H) (1-5)

Stem Cues TlF Cred. Partial Job-Minutia

  1. 1 Back-0= ISRO B/MIN UtEIS Explanation Focus Dist.

Link units ward KIA Only 96 F

3 X

B E

Fix B - doses vs dose rates.

97 H

3 X

B E

Delete reference to Mode 6.

98 F

2 B

S 99 H

2 X

M E

Spell out 1 and 2.

100 H

3 B

S