From:
Gibson, Lauren Sent:
Friday, March 18, 2011 1:43 PM To:
Burkhardt, Janet
Subject:
FW: Draft Request for Additional Information - Palo Verde Nuclear Generating Station, Unit 1, Steam Generator Tube Inspection Report (TAC No.
ME5009)
Attachments:
DRAFT REQUEST FOR ADDITIONAL INFORMATION ME50009.pdf Please add the e-mail below to ADAMS.
Thank you, Lauren From: Gibson, Lauren Sent: Friday, March 18, 2011 1:28 PM To: Russell.Stroud@aps.com Cc: Hall, Randy; Lent, Susan; Burkhardt, Janet
Subject:
Draft Request for Additional Information - Palo Verde Nuclear Generating Station, Unit 1, Steam Generator Tube Inspection Report (TAC No. ME5009)
March 18, 2011 Mr. Russell A. (Rusty) Stroud Licensing Section Leader Regulatory Affairs Palo Verde Nuclear Generating Station Arizona Public Service Company
- Rusty, By letter dated November 08, 2010 (Agencywide Documents Access and Management Systems (ADAMS) Accession No. ML103210208), Arizona Public Service Company (APS, the licensee),
submitted information summarizing the results of the 2010 steam generator (SG) tube inspections at Palo Verde Nuclear Generating Plant Unit 1.
The NRC staff has reviewed the information provided by APS and determined that the additional information requested in the attachment to this e-mail message is needed to complete its review of the SG tube inspections. In order to complete our review of the LAR in a timely manner, please submit your response to the attached RAI by April 19, 2011. Please contact me if APS would like to have a conference call to discuss this request for additional information.
Sincerely, Lauren Gibson, Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation USNRC (301) 415-1056 Randy.Hall@nrc.gov