NRC Comments on Draft Licensee-Developed Exam (Written & Operating Test) (Folder 2)
ML103090619
Person / Time
Site: Nine Mile Point 
Issue date: 10/08/2010
From:
Operations Branch I
To:
Hansell S
Shared Package
ML101900599 List:
References
TAC U01790
Download: ML103090619 (8)


Text

ES-401 Written Examination Review Worksheet Form ES-401-9

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q#

LOK LOD (FtH)

(1-5)

Stem Cues T/F Cred. Partial Job-Minutia

  1. /

Back-Q=

SRO B/M/N UtEtS Explanation Focus Dis!.

Link units ward KIA Only 1

F 3

Y N

S 2

H 3

Y N

S 3

F 2

Y N

S 4

F 3

Y N

S 5

F 4

Y N

S 6

H 3

Y N

S 7

H 2

Y N

S 8

H 2

Y N

S Instructions

[Refer to Section 0 of ES-401 and Appendix B for additional information regarding each of the following concepts.]

1.

Enter the level of knowledge (LOK) of each question as either (F)undamental or (H)igher cognitive level.

2.

Enter the level of difficulty (LOD) of each question using a 1 - 5 (easy - difficult) rating scale (questions in the 2 - 4 range are acceptable).

3.

Check the appropriate box if a psychometric flaw is identified:

The stem lacks sufficient focus to elicit the correct answer (e.g., unclear intent, more information is needed, or too much needless information).

The stem or distractors contain cues (I.e., clues, specific determiners, phrasing, length, etc).

The answer choices are a collection of unrelated true/false statements.

The distractors are not credible; single implausible distractors should be repaired, more than one is unacceptable.

One or more distractors is (are) partially correct (e.g., if the applicant can make unstated assumptions that are not contradicted by stem).

4.

Check the appropriate box if a job content error is identified:

The question is not linked to the job requirements (i.e., the question has a valid KIA but, as written, is not operational in content).

The question requires the recall of knowledge that is too specific for the closed reference test mode (I.e., it is not required to be known from memory).

The question contains data with an unrealistic level of accuracy or inconsistent units (e.g., panel meter in percent with question in gallons).

The question requires reverse logic or application compared to the job requirements.

5.

Check questions that are sampled for conformance with the approved KIA and those that are designated SRO-only (KIA and license level mismatches are unacceptable).

6.

Enter question source: (B)ank, (M)odified, or (N)ew. Check that (M)odified questions meet criteria of ES-401 Section D.2.f.

7.

Based on the reviewer's judgment, is the question as written (U}nsatisfactory (requiring repair or replacement), in need of (E)ditorial enhancement, or (S)atisfactory?

8.

At a minimum, explain any "U" ratings (e.g., how the Appendix B psychometric attributes are not being met).

ES-401 2

Form ES-401-9

---.-........ ~

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q#

LOK LOD (FtH)

(1-5)

Stem Cues TtF Credo Partial Job-Minutia

  1. t Back-Q=

SRO BtMtN UtEtS Explanation Focus Dis!.

Link units ward KIA Only 9

H 3

Y B

S 10 F

3 Y

N S

11 H

3 Y

B S

12 H

4 Y

N S

13 F

2 Y

N S

14 H

2 Y

N S

15 H

3 Y

B S

16 H

3 Y

N S

17 H

4 Y

N S

18 H

3 Y

N S

19 H

4 Y

N S

20 H

4 Y

N S

21 F

4 Y

N S

22 F

3 Y

N S

23 H

4 Y

N S

24 H

3 Y

N S

25 H

3 Y

N S

26 F

2 Y

N S

27 F

3 Y

N S

28 H

3 Y

N S

ES-401 3

Form ES-401-9

~-.-...........

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q#

LOK LOD (F/H)

(1-5) 8tem Cues T/F Credo Partial Job-Minutia

  1. 1 Back-Q=

8RO B/M/N U1E/8 Explanation Focus Dis!.

Link units ward KIA Only 29 H

2 Y

N 8

30 H

2 Y

N 8

31 F

3 Y

N 8

32 H

3 Y

N 8

33 H

2 Y

N 8

34 H

2 Y

N 8

35 F

2 Y

N 8

36 F

3 Y

N 8

37 F

4 Y

N 8

38 F

4 Y

N 8

39 H

3 Y

N 8

40 H

2 X

X Y

N U

Minutia; not operationally valid. Better for GFE. Replaced KIA and Q.

41 H

2 Y

B 8

42 F

2 Y

N 8

43 F

3 Y

N 8

44 H

3 Y

N 8

45 F

2 Y

B 8

46 F

2 Y

B 8

I 47 F

3 Y

B 8

I 48 H

3 Y

N 8

ES-401 4

Form ES-401-9 Q#

1.

LOK (F/H)

2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.

B/M/N

7.

UlE/S

8.

Explanation Stem Focus Cues T/F Credo Dis!.

Partial Job-Link Minutia

  1. 1 units Back ward Q=

KIA SRO Only 49 H

3 Y

B S

50 H

2 Y

B S

51 H

2 Y

B S

52 H

2 Y

B S

. 53 H

3 Y

N S

54 F

3 Y

B S

55 F

2 Y

N S

56 H

2 Y

N S

57 H

2 Y

N S

58 H

3 Y

B S

59 H

3 Y

B S

60 F

3 Y

N S

61 F

2 Y

N S

62 H

2 Y

N S

63 H

2 X

Y B

U A&B implausible, replaced KIA and Q.

64 F

2 Y

M S

65 F

3 Y

B S

LOCA will put water into OW, which dumps to SP via downcomer 66 F

2 Y

N S

67 F

2 Y

N S

68 H

3 Y

B S

ES-401 5

Form ES-401-9 Q#

1 LOK (F/H)

2.

LOD (1-5)

3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.

B/M/N

7.

UtE/S

8.

Explanation Stem Focus Cues T/F Cred.

Dis!.

Partial Job-Link Minutia

  1. 1 units Back ward Q=

KIA SRO Only 69 F

2 Y

N S

70 H

3 Y

B S

71 F

2 Y

M S

72 F

3 Y

B S

73 F

3 Y

N S

74 F

2 Y

N S

75 F

2 Y

N S

76 H

3 Y

Y N

S 77 H

3 Y

Y N

S 78 H

2 Y

Y B

S 79 H

2 Y

Y N

S 80 H

2 Y

Y N

S 81 H

3 Y

Y B

S 82 H

3 Y

Y M

S 83 H

2 Y

Y B

S 84 H

2 Y

Y N

S 85 F

2 Y

Y B

S 86 H

2 Y

Y N

S 87 H

2 Y

Y N

S 88 H

2 Y

Y N

S

ES-401 6

Form ES-401-9

..... ~....--.

1.
2.
3. Psychometric Flaws
4. Job Content Flaws
5. Other
6.
7.
8.

Q#

LOK LCD (F/H)

(1-5)

Stem Cues T/F Cred. Partial Job-Minutia

  1. 1 Back-Q=

SRO B/M/N UtE/S Explanation Focus Dist.

Link units ward KIA Only 89 H

2 Y

Y N

S 90 H

3 Y

Y B

S 91 H

3 Y

Y N

S 92 H

3 Y

Y N

S 93 H

2 Y

Y N

S 94 F

2 Y

Y N

S 95 F

2 Y

Y N

S 96 F

2 Y

Y N

S 97 H

2 Y

Y B

S 98 H

2 Y

Y N

S 99 H

2 Y

Y B

S 100 F

3 Y

Y B

S

Post-submittal changes to Nine Mile Point Unit 2 NRC exam

1. In-Plant JPMs P-l; changed step 4.0 from critical to 5at/Unsat P-2; minor formatting change P-3; added two cues for evaluator {information provided in initial conditions} and minor rewording of two other cues.
2. Simulator JPMs 5-1; Added cue to time compress after step 17; step 11 changed to 5at/Unsat from NA, step 17 changed 3 valves from Pass/Fail to 5at/Unsat 5-2; Added step to verify AOVI0l open and one train GT5 operable, changed step 8 to 5at/Unsat from Pass/Fail (verify), added two cues to indicate two dampers were closed, revised turnover sheet 5-3; Added stopwatch as Tools/Equipment, added "50C has been in service for >1 hour" in initial conditions and turnover sheet, added cue that another operator is monitoring RPV coolant temperatures in step 4,revised step 11 to indicate dual indication vs. green closed indication S-4; minor editorial changes, added cue and role play to step 3, Revised note in step 4, added annunciator to step 5, fixed typo in turnover sheet S-5; minor editorial and formatting changes, removed cue in step 2 (not required), revised turnover sheet to include "Fast loading not required" 5-6; minor editorial and formatting changes, added cue to step 3 and revised cue in step 17, added Sat/Unsat to step 4, revised step 8 Pass/Fail and Sat/Unsat criteria (verify valve position)

S-7; minor editorial and formatting changes, added two expected annunciators to instructor note after step 5, added Sat/Unsat to bullet in step 6 S-8; minor editorial and formatting changes, added cue in step 13 (CCS pump not required, flow is normal)

3. Simulator Scenarios
  1. 1; minor editorial change, minor change to role play in event #5, added "place sync switch to on" in event #7
  1. 2; minor editorial and formatting changes
  1. 3; minor editorial and formatting changes, added examiner note regarding placing SPC in service on page 24
4.

RO Admin JPMs COOl; corrected typos in standard, step #3, and terminating cue, added enhancement to initial conditions and initiating cue, corrected standard in step #5 C002; no changes EP; minor formatting changes EC; minor editorial and formatting changes, changed standard from shaft seal to pump packing, changed two Sat!Unsat criteria in step #4 to Pass/Fail (open and uncapped)

5. SRO Admin JPMs COOl; added enhancement to initiating cue, revised step #3 TS references and included TS actions C002; added enhancement to initiating cue EC; added procedure step in step #3 EP; added enhancements to initial conditions, corrected typo in step #8 EC; minor formatting change