MONTHYEARL-2009-133, License Amendment Request 196 Alternative Source Term and Conforming Amendment2009-06-25025 June 2009 License Amendment Request 196 Alternative Source Term and Conforming Amendment Project stage: Request L-2009-163, Transmittal of Meteorological Data Cd Supporting Alternative Source Term and Conforming License Amendment Request 196 - Supplemental Information2009-07-21021 July 2009 Transmittal of Meteorological Data Cd Supporting Alternative Source Term and Conforming License Amendment Request 196 - Supplemental Information Project stage: Supplement ML0920205292009-07-22022 July 2009 Supplemental Information Needed for Acceptance of Requested Licensing Action Alternate Source Term Amendment Request (LAR 196) (Tac Nos. ME1624 and ME1625) Project stage: Acceptance Review ML0922206962009-08-18018 August 2009 Supplemental Information Needed for Acceptance of Requested Licensing Action Alternate Source Term Amendment Request (LAR 196) Project stage: Acceptance Review L-2009-195, Response to Request for Additional Information on Proposed Amendments to Revise the Technical Specifications to Adopt Alternative Source Term2009-08-26026 August 2009 Response to Request for Additional Information on Proposed Amendments to Revise the Technical Specifications to Adopt Alternative Source Term Project stage: Response to RAI ML0926005302009-09-25025 September 2009 Acceptance Letter Regarding the Alternative Source Term License Amendment Request Project stage: Acceptance Review ML0935006652009-12-17017 December 2009 RAI, Regarding Alternative Source Term Project stage: RAI L-2009-297, Official Service List Title Change, St. Lucie, Turkey Point, Seabrook Station, Duane Arnold Energy Center, Point Beach2009-12-17017 December 2009 Official Service List Title Change, St. Lucie, Turkey Point, Seabrook Station, Duane Arnold Energy Center, Point Beach Project stage: Request L-2010-021, Response to Request for Additional Information Regarding Alternative Source Term Amendment Request2010-02-10010 February 2010 Response to Request for Additional Information Regarding Alternative Source Term Amendment Request Project stage: Response to RAI ML1005603882010-02-25025 February 2010 Request for Additional Information Regarding Request to Adopt the Alternate Source Term Project stage: RAI L-2010-048, Response to Request for Additional Information (RAI) Regarding Alternative Source Term (AST) License Amendment Request (LAR) 1962010-03-15015 March 2010 Response to Request for Additional Information (RAI) Regarding Alternative Source Term (AST) License Amendment Request (LAR) 196 Project stage: Response to RAI ML1007004462010-03-24024 March 2010 Request for Additional Information Regarding Request to Adopt the Alternate Source Team (TAC ME1624 & ME1625) Project stage: RAI L-2010-065, Response to Request for Additional Information (RAI) Regarding Alternative Source Tear (AST) License Amendment Request (LAR) 1962010-04-14014 April 2010 Response to Request for Additional Information (RAI) Regarding Alternative Source Tear (AST) License Amendment Request (LAR) 196 Project stage: Response to RAI L-2010-083, Supplement to License Amendment Request (LAR) 196 and 3/24/2010 Request for Additional Information (RAI) Regarding Alternative Source Term (AST)2010-05-21021 May 2010 Supplement to License Amendment Request (LAR) 196 and 3/24/2010 Request for Additional Information (RAI) Regarding Alternative Source Term (AST) Project stage: Supplement L-2010-121, Revised Meteorological Data for 2005-2009 Supporting Alternative Source Term and Conforming License Amendment Request 1962010-06-11011 June 2010 Revised Meteorological Data for 2005-2009 Supporting Alternative Source Term and Conforming License Amendment Request 196 Project stage: Request L-2010-131, Response to 5/28/2010 Request for Additional Information (RAI) Regarding Alternative Source Term (AST) License Amendment Request (LAR) 1962010-06-23023 June 2010 Response to 5/28/2010 Request for Additional Information (RAI) Regarding Alternative Source Term (AST) License Amendment Request (LAR) 196 Project stage: Request L-2010-137, Revised Radiological Dose Consequences for Alternative Source Term and Conforming License Amendment Request 1962010-06-25025 June 2010 Revised Radiological Dose Consequences for Alternative Source Term and Conforming License Amendment Request 196 Project stage: Request 05000250/LER-2010-002, For Turkey Point, Unit 3 Regarding Fuel Transfer Pump Failure Renders 3B Emergency Diesel Generator Inoperable2010-08-0505 August 2010 For Turkey Point, Unit 3 Regarding Fuel Transfer Pump Failure Renders 3B Emergency Diesel Generator Inoperable Project stage: Request ML1024400682010-08-27027 August 2010 Acceptance Review: Fuel Storage Criticality Analysis LAR (ME4470 and ME4471) Project stage: Acceptance Review L-2010-197, Response to Request for Additional Information Regarding Alternative Source Term License Amendment Request (LAR) 196 and Proposed Changes to Technical Specification (TS) 3/4.7.5 on Control Room Emergency Ventilation System2010-09-15015 September 2010 Response to Request for Additional Information Regarding Alternative Source Term License Amendment Request (LAR) 196 and Proposed Changes to Technical Specification (TS) 3/4.7.5 on Control Room Emergency Ventilation System Project stage: Response to RAI L-2010-226, Summary of NRC Public Meeting Discussion on Meteorological Data for Alternative Source Term and Conforming License Amendment Request 1962010-10-13013 October 2010 Summary of NRC Public Meeting Discussion on Meteorological Data for Alternative Source Term and Conforming License Amendment Request 196 Project stage: Meeting L-2010-293, Response to Request for Additional Information (RAI) Regarding Alternative Source Term (AST) License Amendment Request (LAR) No. 196 and Meteorological Data Sensitivity2010-12-14014 December 2010 Response to Request for Additional Information (RAI) Regarding Alternative Source Term (AST) License Amendment Request (LAR) No. 196 and Meteorological Data Sensitivity Project stage: Response to RAI ML1028710232010-12-16016 December 2010 Summary of Meeting with Florida Power & Light Company to Discuss Turkey Point, Units 3 and 4, Alternative Source Term License Amendment Request Project stage: Meeting ML1035500302011-01-19019 January 2011 Summary of Meeting with Florida Power & Light Company, Regarding Turkey Point, Units 3 & 4, Spent Fuel Criticality Analysis License Amendment Request Project stage: Meeting L-2011-141, Response to NRC Request for Additional Information Regarding Extended Power Uprate License Amendment Request No. 205 and Reactor Systems Issues2011-05-11011 May 2011 Response to NRC Request for Additional Information Regarding Extended Power Uprate License Amendment Request No. 205 and Reactor Systems Issues Project stage: Response to RAI L-2011-154, Response to NRC Request for Additional Information Regarding Fuel Storage Criticality Analysis License Amendment Request No. 2072011-05-20020 May 2011 Response to NRC Request for Additional Information Regarding Fuel Storage Criticality Analysis License Amendment Request No. 207 Project stage: Response to RAI ML1108006662011-06-23023 June 2011 Issuance of Amendments Regarding Alternative Source Term Project stage: Approval L-2011-277, Confirmatory Dose Assessment for Control Room Emergency Ventilation System Air Intake Modification to Satisfy Operating License Conditions 3.H.12011-08-11011 August 2011 Confirmatory Dose Assessment for Control Room Emergency Ventilation System Air Intake Modification to Satisfy Operating License Conditions 3.H.1 Project stage: Request ML11217A0032011-08-16016 August 2011 Request for Withholding Information from Public Disclosure Project stage: Withholding Request Acceptance L-2011-386, License Amendment Request No. 207, Fuel Storage Criticality Analysis Supplement 22011-09-14014 September 2011 License Amendment Request No. 207, Fuel Storage Criticality Analysis Supplement 2 Project stage: Supplement ML11229A1192011-09-23023 September 2011 Correction of Amendment Nos. 244 Ad 240 Regarding Alternative Source Term Project stage: Other ML11216A0572011-10-31031 October 2011 Issuance of Amendments Regarding Fuel Criticality Analysis Project stage: Approval L-2011-540, Safety Evaluation Report Review Supporting Fuel Storage Criticality Amendments 246 and 2422011-12-22022 December 2011 Safety Evaluation Report Review Supporting Fuel Storage Criticality Amendments 246 and 242 Project stage: Other L-2012-313, Administrative License Amendment Request No. 223 Regarding Control Room Emergency Ventilation System Technical Specification2012-08-0707 August 2012 Administrative License Amendment Request No. 223 Regarding Control Room Emergency Ventilation System Technical Specification Project stage: Request L-2012-314, License Amendment Request No. 224 Regarding Technical Specification 3/4.6.2.3 - Recirculation Ph Control System and Natb Basket Minimum Loading Requirement2012-09-0606 September 2012 License Amendment Request No. 224 Regarding Technical Specification 3/4.6.2.3 - Recirculation Ph Control System and Natb Basket Minimum Loading Requirement Project stage: Request L-2013-019, Supplement to Administrative License Amendment Request No. 217 Regarding Operating License Conditions and Technical Specifications2013-01-29029 January 2013 Supplement to Administrative License Amendment Request No. 217 Regarding Operating License Conditions and Technical Specifications Project stage: Supplement 2010-06-23
[Table View] |
Text
UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 December 16, 2010 LICENSEE:
Florida Power & Light Company FACILITY:
Turkey Point, Units 3 and 4
SUBJECT:
SUMMARY
OF OCTOBER 1, 2010, MEETING WITH FLORIDA POWER &
LIGHT COMPANY, ON TURKEY POINT, UNITS 3 AND 4 ALTERNATIVE SOURCE TERM LICENSE AMENDMENT REQUEST (TAC NOS. ME1624 AND ME1625)
On October 1, 2010, a Category 1 public meeting was held between the U.S. Nuclear Regulatory Commission (NRC) and representatives of Florida Power & Light Company (FPL, the licensee) at NRC Headquarters, One White Flint North, 11555 Rockville Pike, Rockville, Maryland. The purpose of the meeting was to discuss the Turkey Point, Units 3 and 4 Alternative Source Term (AST) license amendment request currently under NRC review. A list of attendees is provided as an enclosure.
More specifically, the meeting was held to discuss the AST technical specification (TS) changes associated with the control room emergency ventilation system (CREVS) and the meteorological data. The licensee did not submit any formal presentation materials.
To begin the meeting, the NRC staff provided feedback on the proposed CREVS TS changes contained in the licensee's September 15, 2010 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML102630160), response to the NRC staff's request for additional information. The NRC staff stated that the licensee's responses address the NRC staff's questions.
The NRC staff used the remainder of the meeting to discuss the meteorological data that was submitted by the licensee to support the AST license amendment request. The NRC staff asked clarifying questions regarding the licensee's request for additional information responses contained in letters dated April 14, 2010 (ADAMS Accession No. ML101090027), June 11, 2010 (ADAMS Accession No. ML101650648), June 25, 2010 (ADAMS Accession No. ML101800222), and September 2, 2010 (ADAMS Accession No. ML102510127).
The NRC staff asked the appropriateness of the meteorological data screening and processing.
The licensee responded by stating that Turkey Point has provided documentation that the 2005 2009 meteorological data set used in the dose analyses was adequately acquired and initially screened by appropriate means to ensure that any invalid measurements were rejected.
Further, any substitutions (either from the Land Utilization 10 meter tower or from one South Dade 60 meter tower instrument channel to one another) were allowed only under consistently applied sets of conditions, throughout the 5-year period.
- 2 Members of the public participated via telephone. Public Meeting Feedback forms were not received.
Please direct any inquiries to Jason Paige at 301-415-5888, or Jason.Paige@nrc.gov.
Sincerely, H~-
J~~n Paige, Project Manager Plant Licensing Branch 11-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-250 and 50-251
Enclosure:
List of Attendees cc w/encl: Distribution via ListServ
LIST OF ATrENDEES OCTOBER 1, 2010, MEETING WITH FLORIDA POWER & LIGHT ALTERNATIVE SOURCE TERM LICENSE AMENDMENT REQUEST U. S. Nuclear Regulatory Commission J. White L. Brown H. Walker D. Broaddus A. Boatright Florida Power & Light S. Franzone D. Robinson Numerical Applications, Inc.
J. Harrell B. Ziegler K. Rydman Enclosure
PKG ML102871234 Meetina Notice M o 7 0603 Meetina Summarv 02871023 OFFICE DORLlLPL2-2 /PM DORLlLPL2-2/LA DORLlLPL2-2/BC DORLlLPL2-2/PM NAME JPaige BClayton DBroaddus (FSaba for)
JPaige 12/16/10 DATE 10/15/10 10/14/10 12/16/10