DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 1 of 108 Reviewed By Keith Gillaume Approved By Jesse Arcand Nuclear Safety Related
Yes
No PORC Review Required
Yes
No SRO Approval Of Temporary Changes Required
Yes
No sp-47-011b-(17).docKathy Gille/Kathy GilleDaryell Sipper CONTINUOUS USE Channel 2 (White) 1.0 Purpose 1.1 This procedure provides instruction for calibrating the Reactor Coolant Temperature and Pressurizer Pressure Instrument Loop Channel 2 (White).
1.2 The Reactor Protection System (RPS) maintains an allowable region of power, pressure, and coolant temperature. The RPS protects the integrity of the four fission product boundaries to avoid undue risk to health and safety of the public. The RPS is arranged into four independent channels for redundancy.
2.0 Operational Considerations 2.1 Initial Conditions 2.1.1 Perform this procedure with plant shutdown OR power greater than 10% AND TAVG is greater than 554ºF.
2.1.2 IF performing this procedure at power, THEN perform SP-47-316F, Channel 2 (White)
Reactor Protection Logic Test OR SP-47-316B, Channel 2 (White) Instrument Channel Test, through Reactor Trip and Bypass Breaker Test and Reactor Protection Test sections prior to this calibration.
2.2 Control Room Indications 2.2.1 Performing this procedure causes numerous Control Room alarms.
2.2.2 Performing this procedure affects numerous Control Room instruments.
2.2.3 Performing this procedure may alarm TLA-9 Core Exit T/C Tilts. [CAP032326]
[PCR022832]
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 2 of 108 CONTINUOUS USE Channel 2 (White) 2.3 Technical Specifications And Limiting Conditions For Operation 2.3.1 The following references are information only. Refer to the actual Technical Specifications and Operating License for exact impact.
Tech Spec No.
Summary 3.5.b For on-line testing or in the event of failure of a subsystem 3.5.c If for Tables TS 3.5-2 through TS 3.5-5 the number of channels 3.5.d In the event of subsystem instrumentation channel failure Table No.
Table Item No.
Affected Functional Unit TS 3.5-2 5
Overtemperature T TS 3.5-2 6
Overpower T TS 3.5-2 7
Low Pressurizer Pressure TS 3.5-2 8
High Pressurizer Pressure TS 3.5-3 1d High Pressurizer Pressure TS 3.5-6 2
Reactor Coolant System Subcooling Margin (1)
With number of OPERABLE accident monitoring instrumentation channels (2)
With number of OPERABLE accident monitoring instrumentation channels 3.0 Precautions 3.1 This procedure requires working with potentially dangerous electrical circuits. Refer to the Site Safety Procedures and Policies for safe work practices.
3.2 Remove power to an R/E converter before opening the output circuit.
3.3 Prior to restoring Channel 2 (White), allow the R/E converter to warm up for one hour after restoring the power.
3.4 This procedure might require working with static sensitive devices. Use anti static work precautions as necessary.
3.5 Observe Foreign Material Exclusion as required by MA-AA-102, Dominion Foreign Material Exclusion Process.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 3 of 108 CONTINUOUS USE Channel 2 (White) 4.0 General Instructions 4.1 Overview 4.1.1 This procedure requires two technicians.
4.1.2 The following equipment is affected by this procedure:
- 42301 PRZR Pressure Recorder (PR-429)
Mechanical Control Console C
- 4121701 OTT Setpoint Indicator (TI-406A)
Mechanical Control Console B
- 4121702 Full Power T Indicator (TI-406B)
Mechanical Control Console B
- 4121703 OPT Setpoint Indicator (TI-406C)
Mechanical Control Console B
- 4122202 PRZR Pressure Indicator (PI-430)
Mechanical Control Console B
- 4122402 TAVE Loop A Temperature Indicator (TI-402)
Mechanical Control Console B
- 4255301 OTT Setpoint Recorder (TR-405A red pen)
Mechanical Vertical Panel A
- 4255302 T Recorder (TR-405A green pen)
Mechanical Vertical Panel A
- 4255303 OPT Setpoint Recorder (TR-405A blue pen)
Mechanical Vertical Panel A
- 4840101 PRZR Pressure Instrument Power Supply (PQ-430)
Relay Rack RR-114
- 4840102 PRZR Pressure High Reactor Trip Bistable (PC-430A)
Relay Rack RR-114
- 4840103 PRZR Pressure Safety Injection Trip Bistable (PC-430E/F)
Relay Rack RR-114 SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 4 of 108 CONTINUOUS USE Channel 2 (White) 4.1.3 The following equipment is affected by this procedure (contd):
- 4840104 PRZR Pressure Compensation Unit (PM-430C)
Relay Rack RR-114
- 4840105 PRZR Pressure Low Reactor Trip Bistable (PC-430H)
Relay Rack RR-114
- 4840106 PRZR Pressure Instrument I/I (PM-430A)
Relay Rack RR-114
- 4840107 PRZR Pressure Instrument I/I (PM-430B)
Relay Rack RR-105
- 4840108 PRZR Pressure Power Relief Valve 1B Alarm (PC-430B)
Relay Rack RR-105
- 4840109 PRZR High Pressure Alarm (PC-430C)
Relay Rack RR-105)
- 4840110 PRZR Pressure Instrument I/I (PM-430D)
Relay Rack RR-114
- 4857101 QU>QL Proportional Controller (TC-406L)
Relay Rack RR-114
- 4857102 T Lag Unit (TM-406R)
Relay Rack RR-114
- 4857103 T Lag E/I Converter (TM-406C)
Relay Rack RR-114
- 4857104 T Lag E/I Converter (TM-406P)
Relay Rack RR-114
- 4857105 OTT Rx Trip/Rod Stop Bistable (TC-406C/D)
Relay Rack RR-114
- 4857106 T SP1 I/I Converter (TM-406D)
Relay Rack RR-114
- 4857107 OPT Rx Trip/Rod Stop Bistable (TC-406A/B)
Relay Rack RR-114
- 4892701 TH R/E Converter (TT-402A)
Relay Rack RR-114
- 4892702 TC R/E Converter (TT-402B)
Relay Rack RR-114
- 4892703 TAVG E/I Lead/Lag Unit (TM-402BB)
Relay Rack RR-114 SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 5 of 108 CONTINUOUS USE Channel 2 (White) 4.1.4 The following equipment is affected by this procedure (contd):
- 4892704 TAVG High/Low Trip Unit (TC-402A/D)
Relay Rack RR-114
- 4892705 TAVG Low FW Valve Override Trip Unit (TC-402F)
Relay Rack RR-114
- 4892706 TAVG Impulse Lead/Lag Converter (TM-402O)
Relay Rack RR-114
- 4892707 T SP2 Summer (TM-402V)
Relay Rack RR-114
- 4892708 TAVG I/I Converter (TM-402C)
Relay Rack RR-114
- 4892709 T SP2 I/I Converter (TM-402S)
Relay Rack RR-114
- 4892710 QL>QU Proportional Controller (TC-402R)
Relay Rack RR-114
- 4892711 T SP1 Lead/Lag Converter (TM-402B)
Relay Rack RR-114
- 4892712 Q Current Source (TM-402U)
Relay Rack RR-114
- 4892713 Q Signal Selector (TM-402T)
Relay Rack RR-114
- 4892714 TAVG I/I Converter (TM-402W)
Relay Rack RR-102
- 4892715 TAVG I/I Converter (TM-402EE)
Relay Rack RR-103
- P0430A PRZR Pressure Computer Point
- T0401A RCS Channel 2 (White ) TAVG Computer Point
- T0404A RCS Channel 2 (White) T Computer Point
- T0408A RCS Channel 2 (White) OPT Computer Point
- T0411A RCS Channel 2 (White) OTT Computer Point 4.1.5 IF As Found data is NOT within the Acceptance Range, THEN immediately notify the Shift Manager before continuing.
4.1.6 IF As Found data is NOT within the Acceptance Range, THEN immediately notify the First Line supervisor before continuing.
4.1.7 Complete a Condition Report for nonconforming conditions as required by Corrective Action Program.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 6 of 108 CONTINUOUS USE Channel 2 (White) 4.1.8 IF the plant is shut down, THEN Annunciator, Status Lamp and Computer Point indications might differ from the expected indication. A CR Form is not required for this plant condition, if the reason for the condition is understood.
4.1.9 IF any channel alert is actuated during this test, except for the instrument under test, THEN stop testing AND return all channels to normal (untripped) conditions.
4.1.10 Underlined step numbers designate steps requiring independent verification or concurrent verification of performance.
4.1.11 This procedure is based on Full Power Delta-T 61.785°F.
4.1.12 Because of lead/lag units, allow adequate time for circuits to stabilize before recording outputs.
4.1.13 Some independent verifications are provided by annunciator and end-device indications.
4.2 Other Work Groups And Support Personnel
- Operations 4.3 References 4.3.1 Drawings
- Flow XK-100-10
- Logic E-2038, E-2042
- Wiring XK-100-566, E-2534, E-2535, E-3827
- Interconnection XK-100-624, XK-100-625, XK-100-656, XK-100-661
- Block XK-100-546, XK-100-549, XK-100-552 SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 7 of 108 CONTINUOUS USE Channel 2 (White) 4.3.2 Technical manuals and instruction books
- 4840101, 4840104, 4840106, 4840107, 4857102, 4857105, 4857106, 4857107, 4892703, 4892707, 4892708, 4892709, 4892712, 4892713, 4892714, 4892715 100-1744-1, 100-1762-1, Foxboro
- 4122202, 4121701, 4121702, 4121703, 4122402 445-1, Westinghouse
- 42301, 42553 272239, Yokogawa
- 4892706 236398, NUS Instrument Inc
- 4892701, 4892702, 4892711 P008486, NUS Instrument Inc
- 4840102, 4840103, 4840105, 4840108, 4840109, 4857101, 4857103, 4857104, 4892704, 4892705, 4892710 C-N-430-9, NUS Instrument Inc SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 8 of 108 CONTINUOUS USE Channel 2 (White) 4.3.3 Bill of materials
- 42301, 42553 5147
- 4840101 1254
- 4840003, 3522
- 4840104 3505
- 4840005 1282
- 4840102, 4840103, 4840105, 4840108, 4840109, 4857103, 4857104, 4892704, 4892705 5351
- 4840106, 4840107, 4840110, 4857106, 4892708, 4892709, 4892714, 4892715 1292
- 4121701, 4121702, 4121703, 4122202, 4122402 1211
- 4857101, 4892710 1270
- 4857107, 4857105 1277
- 4891406 1288
- 4857102 1263
- 4892701, 4892702 5207
- 4892703 3506
- 4892706 1258
- 4892707 1256
- 4892711 5206
- 4892712 1297
- 4892713 1283
- 4857101, 4892710 5255 4.3.4 Performance calculations, verifications, and data entry
- PRZR High Press RX Trip Calculation C10818-1 Rev.1
- PRZR Lo Safety Injection Calculation C10818-2 Rev.1
- PRZR Hi Unblock Safety Injection Calculation C10818-3 Rev.1
- PRZR Press Lo Press RX Trip Calculation C10818-4 Rev.1 SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 9 of 108 CONTINUOUS USE Channel 2 (White) 5.0 Equipment Required 5.1 Measuring And Test Equipment
- Decade resistance box, 0 to 1K ohms (2)
- Current calibrator (2)
- Analog simulator
- DC voltage source (4)
- Precision voltmeter (3)
- Precision test resistor
- AC voltmeter
- Step function current calibrator
- Ramp generator
- Plotter, two-channel (Data acquisition devices)
- Fluke 45 precision voltmeter (2) 5.2 Special Tools
- I&C output test connector
- Controlled jumper 5.3 Protective And Safety Equipment
- As required by Site Safety Procedures and Policies SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 10 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.0 Procedure 6.1 Check ICCMS Train A is OPERABLE.
(Operator) 6.2 Notify Shift Manager/Unit Supervisor performing this procedure will make ICCMS Train B INOPERABLE in step 6.6.22.
(SM/US) 6.3 Initial Conditions for Testing 6.3.1 At Mechanical Control Console C, have a Control Room Operator verify DELTA TEMPERATURE RX PROTECTION CHANNEL DEFEAT switch (ES-46374) to position 2 (WHITE) AND PULLOUT.
2 (WHITE) / PULLOUT _______
(Operator)
Concurrent Verification _______
(Operator) 6.3.2 At Mechanical Control Console C, have a Control Room Operator verify TAVE RX PROTECTION CHANNEL DEFEAT switch (ES-46375) to position 2 (WHITE) AND PULLOUT.
2 (WHITE) / PULLOUT _______
(Operator)
Concurrent Verification _______
(Operator) 6.3.3 At Mechanical Control Console C, circle the position of PRZR PRESSURE CONTROL CHANNEL SELECTOR switch (ES-46324).
4-3 / 2-3 / 2-1 _______
(Operator) 6.3.4 IF the PRZR PRESSURE CONTROL CHANNEL SELECTOR switch (ES-46324) is selected to 4-3, THEN N/A Step 6.3.5.
(Operator)
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 11 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.3.5 Notify the Control Room Operator, IF desired, operate Pressurizer Pressure controls in MANUAL using Operations procedure N-RC-36C, Pressurizer Pressure Control before transferring the PRZR PRESSURE CONTROL CHANNEL SELECTOR switch (Step 6.3.6).
(Operator) 6.3.6 At Mechanical Control Console C, have a Control Room Operator place PRZR PRESSURE CONTROL CHANNEL SELECTOR switch (ES-46324) to position 4-3.
4-3 _______
(Operator)
Concurrent Verification _______
(Operator) 6.3.7 Notify the Control Room Operator, IF desired, the controllers may be placed to AUTO.
(Operator)
Concurrent Verification _______
(Operator) 6.3.8 At Mechanical Control Console C, have a Control Room Operator verify PRZR PRESSURE RECORDER INPUT SELECTOR switch (ES-46325) to position 1, 3, or 4 AND circle that position.
1 / 3 / 4 _______
(Operator)
Concurrent Verification _______
(Operator) 6.3.9 At Mechanical Vertical Panel A, have a Control Room Operator verify TR-405 RX CLNT DELTA-TEMP RECORDER SELECTOR switch (ES-46551) to position 2 (WHITE).
2 (WHITE) _______
(Operator)
Concurrent Verification _______
(Operator)
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 12 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.3.10 IF reactor trip breakers are open AND auto SI is disabled, THEN N/A Steps 6.3.11 through 6.3.15.
6.3.11 At Mechanical Vertical Panel A, check the following status lamps are DIM:
6.3.11.1 LOOP A CHAN 2 OTT (44904-0101) _______
6.3.11.2 LOOP B CHAN 1 OTT (44904-0102) _______
6.3.11.3 LOOP A CHAN 4 OTT (44904-0201) _______
6.3.11.4 LOOP B CHAN 3 OTT (44904-0202) _______
6.3.11.5 LOOP A CHAN 2 OPT (44904-0401) _______
6.3.11.6 LOOP B CHAN 1 OPT (44904-0402) _______
6.3.11.7 LOOP A CHAN 4 OPT (44904-0501) _______
6.3.11.8 LOOP B CHAN 3 OPT (44904-0502) _______
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 13 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.3.12 At Mechanical Vertical Panel B, check the following status lamps are DIM:
6.3.12.1 PRESSURIZER 1900 PSIG (44907-0205) _______
6.3.12.2 PRESSURIZER 1900 PSIG (44907-0206) _______
6.3.12.3 PRESSURIZER 1900 PSIG (44907-0207) _______
6.3.12.4 PRESSURIZER 1900 PSIG (44907-0208) _______
6.3.12.5 PRESSURIZER 2385 PSIG (44907-0305) _______
6.3.12.6 PRESSURIZER 2385 PSIG (44907-0306) _______
6.3.12.7 PRESSURIZER 2385 PSIG (44907-0307) _______
6.3.12.8 LOOP B OTT (44907-0505) _______
6.3.12.9 LOOP A OTT (44907-0506) _______
6.3.12.10 LOOP B OTT (44907-0507) _______
6.3.12.11 LOOP A OTT (44907-0508) _______
6.3.12.12 LOOP B OPT (44907-0605) _______
6.3.12.13 LOOP A OPT (44907-0606) _______
6.3.12.14 LOOP B OPT (44907-0607) _______
6.3.12.15 LOOP A OPT (44907-0608) _______
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 14 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.3.13 At Mechanical Vertical Panel C, check the following status lamps are DIM:
6.3.13.1 PRESSURIZER 1815 PSIG (44908-0201) _______
6.3.13.2 PRESSURIZER 1815 PSIG (44908-0202) _______
6.3.13.3 PRESSURIZER 1815 PSIG (44908-0203) _______
6.3.13.4 LOOP A LOW TAVE (44908-0302) _______
6.3.13.5 LOOP A LOW TAVE (44908-0304) _______
6.3.13.6 LOOP B LOW TAVE (44908-0305) _______
6.3.13.7 LOOP B LOW TAVE (44908-0307) _______
6.3.13.8 LOOP A LOW-LOW TAVE (44908-0402) _______
6.3.13.9 LOOP A LOW-LOW TAVE (44908-0404) _______
6.3.13.10 LOOP B LOW-LOW TAVE (44908-0405) _______
6.3.13.11 LOOP B LOW-LOW TAVE (44908-0407) _______
6.3.14 At Mechanical Vertical Panel C, check the following status lamps are BRIGHT:
6.3.14.1 PRESSURIZER >2000 PSIG (44908-0101) _______
6.3.14.2 PRESSURIZER >2000 PSIG (44908-0102) _______
6.3.14.3 PRESSURIZER >2000 PSIG (44908-0103) _______
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 15 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.3.15 Check the following annunciators are OFF:
6.3.15.1 OTT HIGH (47033C) _______
6.3.15.2 OPT HIGH (47033D) _______
6.3.15.3 PRESSURIZER PRESSURE 2385 (47041C) _______
6.3.15.4 PRZR PRESS SI CHANNEL ALERT (47041D) _______
6.3.15.5 OPT CHANNEL RNBACK/RDSTP ALERT (47041Q) _______
6.3.15.6 OTT CHANNEL RNBACK/RDSTP ALERT (47041R) _______
6.3.15.7 PRESSURIZER PRESSURE <1900 (47042D) _______
6.3.15.8 RCS TAVG HIGH (47042H) _______
6.3.15.9 PRESSURIZER PRESSURE LOW (47043D) _______
6.3.15.10 RCS LOOP B TAVG LOW LOW (47043G) _______
6.3.15.11 RCS LOOP A TAVG LOW LOW (47043H) _______
6.3.16 At Recorder 42553, select CAL START message.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 16 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.3.17 In Relay Rack RR-114, place the following bistable output switches to TEST (up):
6.3.17.1 HI TAVG (402A) _______
6.3.17.2 LO/LO TAVG (402D) _______
6.3.17.3 F.W. VALVE OVERRIDE (402F) _______
6.3.17.4 OVER POWER TRIP (406A) _______
6.3.17.5 ROD STOP (directly below OVER POWER TRIP)
(406B) _______
6.3.17.6 OVER TEMP. TRIP (406C) _______
6.3.17.7 ROD STOP (directly below OVER TEMP. TRIP)
(406D) _______
6.3.17.8 HI PRESS. TRIP (430A) _______
6.3.17.9 LO PRESS. TRIP (430H) _______
6.3.17.10 UNBLOCK S.I.
(430F) _______
6.3.17.11 S.I.
(430E) _______
6.3.18 IF reactor trip breakers are open AND auto SI is disabled, THEN N/A Steps 6.3.19 through 6.3.22.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 17 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.3.19 Check the following annunciators are ON:
6.3.19.1 PRESSURIZER PRESSURE 2385 (47041C) _______
6.3.19.2 PRZR PRESS SI CHANNEL ALERT (47041D) _______
6.3.19.3 PRESSURIZER PRESSURE < 1900 (47042D) _______
6.3.19.4 OTT HIGH (47033C) _______
6.3.19.5 OPT HIGH (47033D) _______
6.3.19.6 OPT CHANNEL RNBACK/RDSTP ALERT (47041Q) _______
6.3.19.7 OTT CHANNEL RNBACK/RDSTP ALERT (47041R) _______
6.3.19.8 RCS TAVG HIGH (47042H) _______
6.3.19.9 RCS LOOP A TAVG LOW LOW (47043H) _______
6.3.20 Check the following SER points are ALARMED:
6.3.20.1 REACTOR COOLANT SYSTEM LOOP A CHANNEL 2 TAVG HIGH (944) _______
6.3.20.2 OVERTEMPERATURE DELTA TEMP HIGH (1070) _______
6.3.20.3 PRESSURIZER PRESSURE < 1900 (1071) _______
6.3.20.4 OVERPOWER DELTA TEMP HIGH (1076) _______
6.3.20.5 PRESSURIZER PRESSURE 2385 (1080) _______
6.3.20.6 PRESSURIZER LOW PRESSURE SI CHANNEL ALERT (1173) _______
6.3.20.7 REACTOR COOLANT SYSTEM LOOP A TAVG LO-LO (1583) _______
6.3.20.8 OVERPOWER DELTA TEMP RUNBACK/RODSTOP ALERT (1685) _______
6.3.20.9 OVERTEMPERATURE DELTA TEMP RUNBACK/RODSTOP ALERT (1686) _______
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 18 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.3.21 Check the following status lamps are BRIGHT:
6.3.21.1 LOOP A CHAN 2 OTT (44904-0101) _______
6.3.21.2 LOOP A CHAN 2 OPT (44904-0401) _______
6.3.21.3 PRESSURIZER 1900 PSIG (44907-0206) _______
6.3.21.4 PRESSURIZER 2385 PSIG (44907-0306) _______
6.3.21.5 LOOP A OTT (44907-0506) _______
6.3.21.6 LOOP A OPT (44907-0606) _______
6.3.21.7 PRESSURIZER > 2000 PSIG (44908-0102) _______
6.3.21.8 PRESSURIZER 1815 PSIG (44908-0202) _______
6.3.21.9 LOOP A LOW TAVE (44908-0302) _______
6.3.21.10 LOOP A LOW-LOW TAVE (44908-0402) _______
6.3.22 Check the following computer points are TRIPPED:
6.3.22.1 RCLA OVERPOWER DT CHAN 2 (T0400D) _______
6.3.22.2 RCLA OVERTEMP DT CHAN 2 (T0403D) _______
6.3.22.3 PRESSURIZER HI P CH 2 (P0481D) _______
6.3.22.4 PRESSURIZER LOW P CHAN 2 (P0485D) _______
6.3.22.5 PRESSURIZER LO P CH 2 SI (P0490D) _______
Note If Pressurizer Pressure is greater than 2000 psig, the following computer point will not alarm.
6.3.22.6 SAFETY INJECTION CHAN 2 UN BLK (P0493D) _______
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 19 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.3.23 IF Operations desires to avoid nuisance alarms, THEN have a Control Room Operator DISABLE the following SER points, otherwise N/A the substeps:
6.3.23.1 RCS LOOP A CHANNEL 2 TAVG DEVIATION (974) _______
(Operator) 6.3.23.2 RCS LOOP A CHANNEL 2 DELTA TEMP DEVIATION (978) _______
(Operator) 6.4 TH, TC, T, and TAVG 6.4.1 In Relay Rack RR-114, open the signal injection test panel cover AND check the following:
6.4.1.1 Annunciator (47035K), PROCESS PROTECT RACK 2 CHANNEL TEST is ON.
6.4.1.2 SER (1680) PROCESS PROTECT RACK 2 CHANNEL TEST is ALARMED.
6.4.2 At the signal injection test panel, open the states block cover.
6.4.3 Open states block terminals, 3, 6, 9, and 12.
6.4.4 In Relay Rack RR-114, at the TH signal injection test jacks, connect a decade resistance box.
6.4.5 Adjust the TH decade resistance box to 425 ohms.
6.4.6 At the TC signal injection test jacks, connect a decade resistance box.
6.4.7 Adjust the TC decade resistance box to 425 ohms.
6.4.8 Place the following signal injection switches to TEST (up):
6.4.8.1 TH 6.4.8.2 TC 6.4.9 At THL test point jacks, connect a precision voltmeter.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 20 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.10 Using Table 6-1, perform a calibration test of TT-402A.
Table 6-1 INPUT (ohms)
OUTPUT (vdc)
TT-402A 4892701 THL Accuracy: +/- 0.05 vdc TH DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
400.08 0.40 0.35 to 0.45 2
408.24 2.00 1.95 to 2.05 3
416.38 3.60 3.55 to 3.65 4
424.48 5.20 5.15 to 5.25 5
432.55 6.80 6.75 to 6.85 6
440.60 8.40 8.35 to 8.45 7
448.62 10.00 9.95 to 10.05 8
460.59 12.40 12.35 to 12.45 M&TE ID DESCRIPTION Decade resistance box Precision voltmeter 6.4.11 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 21 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.12 At TCL test point jacks, connect a precision voltmeter.
6.4.13 Using Table 6-2, perform a calibration test of TT-402B.
Table 6-2 INPUT (ohms)
OUTPUT (vdc)
TT-402B 4892702 TCL Accuracy: +/- 0.05 vdc TC DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
400.17 0.40 0.35 to 0.45 2
408.32 2.00 1.95 to 2.05 3
416.44 3.60 3.55 to 3.65 4
424.54 5.20 5.15 to 5.25 5
432.60 6.80 6.75 to 6.85 6
440.63 8.40 8.35 to 8.45 7
448.64 10.00 9.95 to 10.05 8
460.59 12.40 12.35 to 12.45 M&TE ID DESCRIPTION Decade resistance box Precision voltmeter 6.4.14 Are all Final Data entries within the acceptance range?
Yes
No 6.4.15 Place the TH signal injection switch to NORMAL (down).
6.4.16 Remove the decade box from the TH signal injection test jacks.
6.4.17 Place the TC signal injection switch to NORMAL (down).
6.4.18 Remove the decade box from the TC signal injection test jacks.
6.4.19 Remove power to TT-402A by unplugging the power cord.
6.4.20 At TT-402A, remove the signal cord set.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 22 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.21 At pins W(+) and X(), connect a 0 to 10 vdc voltage source.
6.4.22 Remove power to TT-402B by unplugging the power cord.
6.4.23 At TT-402B, remove the signal cord set.
6.4.24 At pins W(+) and X(), connect a 0 to 10 vdc voltage source.
6.4.25 At T test point jacks, connect a precision voltmeter.
6.4.26 At T LAG test point jacks, connect a precision voltmeter.
6.4.27 Adjust the voltage source at TT-402B for a TCL output of 0.40 vdc.
Note Device DB-1 is a resistive summing network with no calibration adjustments.
A work order would be required to repair or replace if values are NOT within ACCEPTANCE RANGE.
6.4.28 Using Table 6-3 and Table 6-4, perform a calibration test of DB-1 and TM-406R.
Table 6-3 INPUT (vdc)
OUTPUT (vdc)
DB-1 T
Accuracy: +/- 0.04 vdc THL DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
0.40 0.00 0.04 to 0.04 2
2.00 1.60 1.56 to 1.64 3
3.60 3.20 3.16 to 3.24 4
5.20 4.80 4.76 to 4.84 5
6.80 6.40 6.36 to 6.44 6
8.40 8.00 7.96 to 8.04 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 23 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Table 6-4 INPUT (vdc)
OUTPUT (vdc)
TM-406R 4857102 T LAG Accuracy: +/- 0.05 vdc T
DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
0.00 0.00 0.05 to 0.05 2
1.60 2.00 1.95 to 2.05 3
3.20 4.00 3.95 to 4.05 4
4.80 6.00 5.95 to 6.05 5
6.40 8.00 7.95 to 8.05 6
8.00 10.00 9.95 to 10.05 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.4.29 Are all Final Data entries within the acceptance range for Table 6-3 and Table 6-4?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 24 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.30 Adjust the voltage source at TT-402B for a TCL output of 2.40 vdc.
6.4.31 Using Table 6-5, perform a calibration test of DB-1.
Table 6-5 INPUT (vdc)
OUTPUT (vdc)
DB-1 T
Accuracy: +/- 0.04 vdc THL DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
2.40 0.00 0.04 to 0.04 2
4.00 1.60 1.56 to 1.64 3
5.60 3.20 3.16 to 3.24 4
7.20 4.80 4.76 to 4.84 5
8.80 6.40 6.36 to 6.44 6
10.40 8.00 7.96 to 8.04 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.4.32 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 25 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.33 Adjust the voltage source at TT-402B for a TCL output of 4.40 vdc.
6.4.34 Using Table 6-6, perform a calibration test of DB-1.
Table 6-6 INPUT (vdc)
OUTPUT (vdc)
DB-1 T
Accuracy: +/- 0.04 vdc THL DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
4.40 0.00 0.04 to 0.04 2
6.00 1.60 1.56 to 1.64 3
7.60 3.20 3.16 to 3.24 4
9.20 4.80 4.76 to 4.84 5
10.80 6.40 6.36 to 6.44 6
12.40 8.00 7.96 to 8.04 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.4.35 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 26 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.36 Adjust the voltage source at TT-402B for a TCL output of 6.40 vdc.
6.4.37 Using Table 6-7, perform a calibration test of DB-1.
Table 6-7 INPUT (vdc)
OUTPUT (vdc)
DB-1 T
Accuracy: +/- 0.04 vdc THL DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
6.40 0.00 0.04 to 0.04 2
8.00 1.60 1.56 to 1.64 3
9.60 3.20 3.16 to 3.24 4
11.20 4.80 4.76 to 4.84 5
12.40 6.00 5.96 to 6.04 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.4.38 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 27 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.39 Adjust the voltage source at TT-402B for a TCL output of 8.40 vdc.
6.4.40 Using Table 6-8, perform a calibration test of DB-1.
Table 6-8 INPUT (vdc)
OUTPUT (vdc)
DB-1 T
Accuracy: +/- 0.04 vdc THL DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
8.40 0.00 0.04 to 0.04 2
10.00 1.60 1.56 to 1.64 3
11.60 3.20 3.16 to 3.24 4
12.40 4.00 3.96 to 4.04 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.4.41 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 28 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.42 Adjust the voltage source at TT-402B for a TCL output of 10.40 vdc.
6.4.43 Using Table 6-9, perform a calibration test of DB-1.
Table 6-9 INPUT (vdc)
OUTPUT (vdc)
DB-1 T
Accuracy: +/- 0.04 vdc THL DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
10.4 0.00 0.04 to 0.04 2
12.0 1.60 1.56 to 1.64 3
12.4 2.00 1.96 to 2.04 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.4.44 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 29 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.45 Adjust the voltage source at TT-402B for a TCL output of 12.40 vdc.
6.4.46 Using Table 6-10, perform a calibration test of DB-1.
Table 6-10 INPUT (vdc)
OUTPUT (vdc)
DB-1 T
Accuracy: +/- 0.04 vdc THL DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
12.40 0.00 0.04 to 0.04 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.4.47 At T test point jacks, remove the precision voltmeter.
6.4.48 At TM-406R, remove the signal cord set.
6.4.49 At pins W(+) and X(), connect a 0 to 10 vdc voltage source.
6.4.50 In Relay Rack RR-103, TP/TM406C, connect a precision voltmeter.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 30 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.51 Using Table 6-11, perform a calibration test of TM-406C.
Table 6-11 INPUT (vdc)
OUTPUT (mvdc)
TM-406C 4857103 TP/TM406C Accuracy: +/- 2.0 mvdc T LAG DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
0.000 100.0 98.0 to 102.0 2
2.317 200.0 198.0 to 202.0 3
4.634 300.0 298.0 to 302.0 4
6.951 400.0 398.0 to 402.0 5
9.268 500.0 498.0 to 502.0 5
9.268 500.0 498.0 to 502.0 4
6.951 400.0 398.0 to 402.0 3
4.634 300.0 298.0 to 302.0 2
2.317 200.0 198.0 to 202.0 1
0.000 100.0 98.0 to 102.0 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.4.52 Are all Final Data entries within the acceptance range?
Yes
No 6.4.53 In Relay Rack RR-103, TP/TM406C, remove the precision voltmeter.
6.4.54 In Relay Rack RR-114, TM-406P, remove the signal cord set.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 31 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note Figure 1 shows the I&C output test connector.
6.4.55 At TM-406P, connect an I&C output test connector and 10 ohm precision test resistor.
6.4.56 At TM-406P, connect the signal cord set.
6.4.57 At TM-406P, at the I&C output test connector, connect a precision voltmeter.
Figure 1 CORD SET 10 ohm test resistor OUTPUT TEST CONNECTOR CURRENT TO CURRENT OR VOLTAGE TO CURRENT CONVERTER SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 32 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note Table 6-12, Table 6-13, Table 6-14, and Table 6-15 may be performed concurrently.
6.4.58 Using Table 6-12, perform a calibration test of TM-406P.
Table 6-12 INPUT (vdc)
OUTPUT (mvdc)
TM-406P 4857104 TM-406P Accuracy: +/- 2.0 mvdc T LAG DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
0.000 100.0 98.0 to 102.0 2
2.317 200.0 198.0 to 202.0 3
4.634 300.0 298.0 to 302.0 4
6.951 400.0 398.0 to 402.0 5
9.268 500.0 498.0 to 502.0 5
9.268 500.0 498.0 to 502.0 4
6.951 400.0 398.0 to 402.0 3
4.634 300.0 298.0 to 302.0 2
2.317 200.0 198.0 to 202.0 1
0.000 100.0 98.0 to 102.0 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter Precision test resistor 6.4.59 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 33 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.60 Using Table 6-13, perform a calibration test of TI-406B.
Table 6-13 INPUT (mvdc)
OUTPUT (%)
TI-406B 4121702 Accuracy: +/- 3%
TM-406P DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 0.0
<0 to 3.0 2
200 37.5 34.5 to 40.5 3
300 75.0 72.0 to 78.0 4
400 112.5 109.5 to 115.5 5
500 150.0 147.0 to >150 5
500 150.0 147.0 to >150 4
400 112.5 109.5 to 115.5 3
300 75.0 72.0 to 78.0 2
200 37.5 34.5 to 40.5 1
100 0.0
<0 to 3.0 M&TE ID DESCRIPTION Precision voltmeter Precision test resistor 6.4.61 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 34 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.62 Using Table 6-14, perform a calibration test of T0404A.
Table 6-14 INPUT (mvdc)
OUTPUT (%)
T0404A Accuracy: +/- 1.5%
TM-406P DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 0.0 1.5 to 1.5 2
200 37.5 36.0 to 39.0 3
300 75.0 73.5 to 76.5 4
400 112.5 111.0 to 114.0 5
500 150.0 148.5 to 151.5 M&TE ID DESCRIPTION Precision voltmeter Precision test resistor 6.4.63 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 35 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note Recorder TR-405A is calibrated in SP-47-011A.
6.4.64 Using Table 6-15, check TR-405A (green pen).
Table 6-15 INPUT (mvdc)
OUTPUT (%)
TR-405A 4255302 Accuracy: +/- 0.5%
TM-406P DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
300 75.0 74.5 to 75.5 M&TE ID DESCRIPTION Precision voltmeter Precision test resistor 6.4.65 At TM-406P, remove all test equipment.
6.4.66 At TM-406P, connect the signal cord set.
6.4.67 At TM-406R, remove all test equipment.
6.4.68 At TM-406R, connect the signal cord set.
6.4.69 At T LAG test point jacks, remove the precision voltmeter.
6.4.70 At TAVG VOLTS test point jacks, connect a precision voltmeter.
6.4.71 At TAVG MA test point jacks, connect a precision voltmeter.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 36 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.72 Adjust the voltage source at TT-402B for a TCL output of 0.40 vdc.
Note Device DB-1 is a resistive summing network with no calibration adjustments.
A work order would be required to repair or replace if values are NOT within ACCEPTANCE RANGE.
Note Use the voltage sources at TT-402A and TT-402B to vary input.
6.4.73 Using Table 6-16 and Table 6-17, perform a calibration test of DB-1 and TM-402BB.
Table 6-16 INPUT (vdc)
OUTPUT (vdc)
DB-1 TAVG VOLTS Accuracy: +/- 0.04 vdc THL DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
3.60 2.00 1.96 to 2.04 2
5.20 2.80 2.76 to 2.84 3
6.80 3.60 3.56 to 3.64 4
8.40 4.40 4.36 to 4.44 5
10.00 5.20 5.16 to 5.24 6
11.60 6.00 5.96 to 6.04 7
12.40 6.40 6.36 to 6.44 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 37 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Table 6-17 INPUT (vdc)
OUTPUT (mvdc)
TM-402BB 4892703 TAVG MA Accuracy: +/- 2.0 mvdc TAVG VOLTS DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
2.00 100.0 98.0 to 102.0 2
4.00 200.0 198.0 to 202.0 3
6.00 300.0 298.0 to 302.0 4
8.00 400.0 398.0 to 402.0 5
10.00 500.0 498.0 to 502.0 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.4.74 Are all Final Data entries within the acceptance range for Table 6-16 and Table 6-17?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 38 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.75 Adjust the voltage source at TT-402B for a TCL output of 3.40 vdc.
6.4.76 Using Table 6-18, perform a calibration test of DB-1.
Table 6-18 INPUT (vdc)
OUTPUT (vdc)
DB-1 TAVG VOLTS Accuracy: +/- 0.04 vdc THL DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
3.40 3.40 3.36 to 3.44 2
5.00 4.20 4.16 to 4.24 3
6.60 5.00 4.96 to 5.04 4
8.20 5.80 5.76 to 5.84 5
9.80 6.60 6.56 to 6.64 6
11.40 7.40 7.36 to 7.44 7
12.40 7.90 7.86 to 7.94 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.4.77 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 39 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.78 Adjust the voltage source at TT-402B for a TCL output of 6.40 vdc.
6.4.79 Using Table 6-19, perform a calibration test of DB-1.
Table 6-19 INPUT (vdc)
OUTPUT (vdc)
DB-1 TAVG VOLTS Accuracy: +/- 0.04 vdc THL DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
6.40 6.40 6.36 to 6.44 2
8.00 7.20 7.16 to 7.24 3
9.60 8.00 7.96 to 8.04 2
11.20 8.80 8.76 to 8.84 3
12.40 9.40 9.36 to 9.44 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.4.80 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 40 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.81 Adjust the voltage source at TT-402B for a TCL output of 9.40 vdc.
6.4.82 Using Table 6-20, perform a calibration test of DB-1.
Table 6-20 INPUT (vdc)
OUTPUT (vdc)
DB-1 TAVG VOLTS Accuracy: +/- 0.04 vdc THL DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
9.40 9.40 9.36 to 9.44 2
10.60 10.00 9.96 to 10.04 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.4.83 Adjust the voltage source at TT-402B for a TCL output of 10.00 vdc.
6.4.84 Using Table 6-21, perform a calibration test of DB-1.
Table 6-21 INPUT (vdc)
OUTPUT (vdc)
DB-1 TAVG VOLTS Accuracy: +/- 0.04 vdc THL DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
10.00 10.00 9.96 to 10.04 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 41 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.85 At THL test point jacks, remove the precision voltmeter.
6.4.86 At TCL test point jacks, remove the precision voltmeter.
6.4.87 At TAVG VOLTS test point jacks, remove the precision voltmeter.
6.4.88 At the TAVG signal injection test jacks, connect a current calibrator.
6.4.89 Place the TAVG signal injection switch to TEST (up).
Note Table 6-22, Table 6-23, and Table 6-24 may be performed in any order.
6.4.90 Using Table 6-22, perform a calibration test by raising the current calibrator output at TAVG until the HI TAVG (402A) bistable proving lamp is OFF.
Table 6-22 High TAVG (576.5°F)
TC-402A 4892704 TAVG MA Accuracy: +/- 2.0 mvdc SETPOINT DESIRED AS FOUND ACCEPTANCE RANGE FINAL Set (mvdc) 326.0 324.0 to 328.0 Reset (mvdc) 322.0 320.0 to 324.0 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
- 1000 mvdc slow resolution SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 42 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.91 Using Table 6-23, perform a calibration test by lowering the current calibrator output at TAVG until the F.W. VALVE OVERRIDE (402F) bistable proving lamp is OFF.
Table 6-23 Low TAVG FW Valve Override (554.5°F)
TC-402F 4892705 TAVG MA Accuracy: +/- 2.0 mvdc SETPOINT DESIRED AS FOUND ACCEPTANCE RANGE FINAL Set (mvdc) 238.0 236.0 to 240.0 Reset (mvdc) 242.0 240.0 to 244.0 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
- 1000 mvdc slow resolution 6.4.92 Using Table 6-24, perform a calibration test by lowering the current calibrator output at TAVG until the LO/LO TAVG (402D) bistable proving lamp is OFF. _______
Table 6-24 Low-Low TAVG Steam Line Isolation (541 °F)
TC-402D 4892704 TAVG MA Accuracy: +/- 2.0 mvdc SETPOINT DESIRED AS FOUND ACCEPTANCE RANGE FINAL Set (mvdc) 184.0 182.0 to 186.0 Reset (mvdc) 188.0 186.0 to 190.0 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
- 1000 mvdc slow resolution 6.4.93 In Relay Rack RR-102, TP/TM402C, connect a precision voltmeter.
6.4.94 In Relay Rack RR-102, TM-402W, remove the signal cord set.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 43 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note Figure 2 shows the I&C output test connector.
6.4.95 At TM-402W, connect an I&C output test connector and 10 ohm precision test resistor.
6.4.96 At TM-402W, connect the signal cord set.
6.4.97 At TM-402W, at the I&C output test connector, connect a precision voltmeter. _______
Figure 2 CORD SET 10 ohm test resistor OUTPUT TEST CONNECTOR CURRENT TO CURRENT OR VOLTAGE TO CURRENT CONVERTER SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 44 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note Table 6-25, Table 6-26, Table 6-27, and Table 6-28 may be performed concurrently.
6.4.98 Using Table 6-25, perform a calibration test of TM-402C.
Table 6-25 INPUT (mvdc)
OUTPUT (mvdc)
TM-402C 4892708 TP/TM402C Accuracy: +/- 2.0 mvdc TAVG MA DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 100.0 98.0 to 102.0 2
200 200.0 198.0 to 202.0 3
300 300.0 298.0 to 302.0 4
400 400.0 398.0 to 402.0 5
500 500.0 498.0 to 502.0 5
500 500.0 498.0 to 502.0 4
400 400.0 398.0 to 402.0 3
300 300.0 298.0 to 302.0 2
200 200.0 198.0 to 202.0 1
100 100.0 98.0 to 102.0 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.4.99 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 45 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.100 Using Table 6-26, perform a calibration test of TI-402.
Table 6-26 INPUT (mvdc)
OUTPUT (°F)
TI-402 4122402 Accuracy: +/- 2°F TP/TM402C DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 520
<520 to 522 2
200 545 543 to 547 3
300 570 568 to 572 4
400 595 593 to 597 5
500 620 618 to >620 5
500 620 618 to >620 4
400 595 593 to 597 3
300 570 568 to 572 2
200 545 543 to 547 1
100 520
<520 to 522 M&TE ID DESCRIPTION Precision voltmeter 6.4.101 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 46 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.102 Using Table 6-27, perform a calibration test of TM-402W.
Table 6-27 INPUT (mvdc)
OUTPUT (mvdc)
TM-402W 4892714 TM-402W Accuracy: +/- 2.0 mvdc TP/TM402C DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 100.0 98.0 to 102.0 2
200 200.0 198.0 to 202.0 3
300 300.0 298.0 to 302.0 4
400 400.0 398.0 to 402.0 5
500 500.0 498.0 to 502.0 5
500 500.0 498.0 to 502.0 4
400 400.0 398.0 to 402.0 3
300 300.0 298.0 to 302.0 2
200 200.0 198.0 to 202.0 1
100 100.0 98.0 to 102.0 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter Precision test resistor 6.4.103 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 47 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.104 Using Table 6-28, perform a calibration test of T0401A.
Table 6-28 INPUT (mvdc)
OUTPUT (°F)
T0401A Accuracy: +/- 1.0°F TM-402W DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 520.0 519.0 to 521.0 2
200 545.0 544.0 to 546.0 3
300 570.0 569.0 to 571.0 4
400 595.0 594.0 to 596.0 5
500 620.0 619.0 to 621.0 M&TE ID DESCRIPTION Precision voltmeter Precision test resistor 6.4.105 Are all Final Data entries within the acceptance range?
Yes
No 6.4.106 At TM-402W, remove all test equipment.
6.4.107 At TM-402W, connect the signal cord set.
6.4.108 In Relay Rack RR-102, TP/TM402EE, connect a precision voltmeter.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 48 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.4.109 Using Table 6-29, perform a calibration test of TM-402EE.
Table 6-29 INPUT (mvdc)
OUTPUT (mvdc)
TM-402EE 4892715 TP/TM402EE Accuracy: +/- 2.0 mvdc TP/TM402C DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 100.0 98.0 to 102.0 2
200 200.0 198.0 to 202.0 3
300 300.0 298.0 to 302.0 4
400 400.0 398.0 to 402.0 5
500 500.0 498.0 to 502.0 5
500 500.0 498.0 to 502.0 4
400 400.0 398.0 to 402.0 3
300 300.0 298.0 to 302.0 2
200 200.0 198.0 to 202.0 1
100 100.0 98.0 to 102.0 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.4.110 Are all Final Data entries within the acceptance range?
Yes
No 6.4.111 At TP/TM402EE, remove the precision voltmeter.
6.4.112 At TP/TM402C, remove the precision voltmeter.
6.4.113 In Relay Rack RR-114, TAVG MA test point jacks, remove the precision voltmeter.
6.4.114 Place the TAVG signal injection switch to NORMAL (down).
6.4.115 At the TAVG signal injection test jacks, remove the current calibrator.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 49 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.5 Flux Tilt 6.5.1 In Relay Rack RR-114, Q0 test point jacks, connect a precision voltmeter.
Note Adjust TM-402U as necessary.
6.5.2 Using Table 6-30, perform a calibration test of Q0.
Table 6-30 Q0 TM-402U 4892712 Q0 Accuracy: +/- 2.0 mvdc SETPOINT DESIRED AS FOUND ACCEPTANCE RANGE FINAL*
Set (mvdc) 100.0 98.0 to 102.0 M&TE ID DESCRIPTION Precision voltmeter
- Final value should be optimized to 100.0 mvdc 6.5.3 In Relay Rack RR-114, at the QU signal injection test jacks, connect a 0 to 10 vdc source.
6.5.4 At the QL signal injection test jacks, connect a 0 to 10 vdc source.
6.5.5 Place the following signal injection switches to TEST (up):
6.5.5.1 QU 6.5.5.2 QL 6.5.6 At the following test point jacks, connect a precision voltmeter as necessary:
6.5.6.1 QU 6.5.6.2 QL 6.5.6.3 QU > QL 6.5.6.4 QL > QU 6.5.7 Adjust the voltage source at QL for a QL output of 0.00 vdc.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 50 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note Table 6-31 AS FOUND values may be out of acceptance range due to cycle Reload Safety Evaluation for COLR. A CR is NOT required for that circumstance.
Note Obtain AS FOUND values for Table 6-31 and Table 6-32 prior to making adjustments to TC-406L.
6.5.8 Using Table 6-31, perform a calibration test of TC-406L.
Table 6-31 INPUT (vdc)
OUTPUT (mvdc)
TC-406L 4857101 QU > QL Accuracy: +/- 2.0 mvdc QU DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
0.24
<100.0
<100.0 2
0.44 100.0 98.0 to 102.0 3
1.00 123.0 121.0 to 125.0 4
2.00 164.0 162.0 to 166.0 5
3.00 205.1 203.1 to 207.1 6
4.00 246.2 244.2 to 248.2 7
5.00 287.2 285.2 to 289.2 8
6.00 328.3 326.3 to 330.3 9
7.00 369.4 367.4 to 371.4 10 8.00 410.5 408.5 to 412.5 11 9.00 451.5 449.5 to 453.5 12 10.00 492.6 490.6 to 494.6 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter Precision voltmeter 6.5.9 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 51 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note Table 6-32 AS FOUND values may be out of acceptance range due to cycle Reload Safety Evaluation for COLR. A CR is NOT required for that circumstance.
6.5.10 Adjust the voltage source at QL for a QL output of 4.00 vdc.
6.5.11 Using Table 6-32, perform a calibration test of TC-406L.
Table 6-32 INPUT (vdc)
OUTPUT (mvdc)
TC-406L 4857101 QU > QL Accuracy: +/- 2.0 mvdc QU DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
4.00
<100.0
<100.0 2
4.44 100.0 98.0 to 102.0 3
5.00 123.0 121.0 to 125.0 4
6.00 164.0 162.0 to 166.0 5
7.00 205.1 203.1 to 207.1 6
8.00 246.2 244.2 to 248.2 7
9.00 287.2 285.2 to 289.2 8
10.00 328.3 326.3 to 330.3 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter Precision voltmeter 6.5.12 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 52 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.5.13 Adjust the voltage source at QU for a QU output of 0.00 vdc.
Note Obtain AS FOUND values for Table 6-33 and Table 6-34 prior to making adjustments to TC-402R.
6.5.14 Using Table 6-33, perform a calibration test of TC-402R.
Table 6-33 INPUT (vdc)
OUTPUT (mvdc)
TC-402R 4892710 QL > QU Accuracy: +/- 2.0 mvdc QL DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
1.00
<100.0
<100 2
1.32 99.6 97.6 to 101.6 3
2.00 169.6 167.6 to 171.6 4
3.00 272.4 270.4 to 274.4 5
4.00 375.2 373.2 to 377.2 6
5.00 478.0 476.0 to 480.0 7
5.21 499.6 497.6 to 501.6 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter Precision voltmeter 6.5.15 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 53 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.5.16 Adjust the voltage source at QU for a QU output of 4.00 vdc.
6.5.17 Using Table 6-34, perform a calibration test of TC-402R.
Table 6-34 INPUT (vdc)
OUTPUT (mvdc)
TC-402R 4892710 QL > QU Accuracy: +/- 2.0 mvdc QL DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
4.00
<100.0
<100.0 2
5.32 99.6 97.6 to 101.6 3
6.00 169.6 167.6 to 171.6 4
7.00 272.4 270.4 to 274.4 5
8.00 375.2 373.2 to 377.2 6
9.00 478.0 476.0 to 480.0 7
9.21 499.6 497.6 to 501.6 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter Precision voltmeter 6.5.18 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 54 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note Use the voltage source at QU and QL as required to vary inputs.
6.5.19 Using Table 6-35 and Table 6-36, perform a calibration test of TM-402T.
Table 6-35 INPUT (mvdc)
OUTPUT (mvdc)
TM-402T 4892713 Q
Accuracy: +/- 2.0 mvdc QL > QU DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
<98 100.0 98.0 to 102.0 2
200 200.0 198.0 to 202.0 3
300 300.0 298.0 to 302.0 4
400 400.0 398.0 to 402.0 5
500 500.0 498.0 to 502.0 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter Table 6-36 INPUT (mvdc)
OUTPUT (mvdc)
TM-402T 4892713 Q
Accuracy: +/- 2.0 mvdc QU > QL DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
<98 100.0 98.0 to 102.0 2
200 200.0 198.0 to 202.0 3
300 300.0 298.0 to 302.0 4
400 400.0 398.0 to 402.0 5
476 476.0 474.0 to 478.0 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.5.20 Are all Final Data entries within the acceptance range for Table 6-35 and Table 6-36?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 55 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.5.21 At the following test point jacks, remove the precision voltmeter:
6.5.21.1 QU > QL 6.5.21.2 QL > QU 6.6 Overtemperature T Setpoint 6.6.1 In Relay Rack RR-114, at TM-402B, remove the signal cord set.
6.6.2 At pins W(+) and X(), connect a current calibrator.
6.6.3 At TM-406D, remove the signal cord set.
Note Figure 3 shows the I&C output test connector.
6.6.4 At TM-406D, connect an I&C output test connector and 10 ohm precision test resistor.
6.6.5 At TM-406D, connect the signal cord set.
6.6.6 At TM-406D, at the I&C output test connector, connect a precision voltmeter. _______
6.6.7 At TSP1 test point jacks, connect a precision voltmeter.
Figure 3 CORD SET 10 ohm test resistor OUTPUT TEST CONNECTOR CURRENT TO CURRENT OR VOLTAGE TO CURRENT CONVERTER SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 56 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note Table 6-37, Table 6-38, Table 6-39, and Table 6-40 may be performed concurrently.
Note Use the current calibrator at TM-402B to vary the input.
6.6.8 Using Table 6-37, perform a calibration test of TM-406D.
Table 6-37 INPUT (mvdc)
OUTPUT (mvdc)
TM-406D 4857106 TM-406D Accuracy: +/- 2.0 mvdc TSP1 DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 100.0 98.0 to 102.0 2
200 200.0 198.0 to 202.0 3
300 300.0 298.0 to 302.0 4
400 400.0 398.0 to 402.0 5
500 500.0 498.0 to 502.0 5
500 500.0 498.0 to 502.0 4
400 400.0 398.0 to 402.0 3
300 300.0 298.0 to 302.0 2
200 200.0 198.0 to 202.0 1
100 100.0 98.0 to 102.0 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter Precision test resistor 6.6.9 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 57 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.6.10 Using Table 6-38, perform a calibration test of TI-406A.
Table 6-38 INPUT (mvdc)
OUTPUT (%)
TI-406A 4121701 Accuracy: +/- 3%
TM-406D DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 0.0
<0 to 3.0 2
200 37.5 34.5 to 40.5 3
300 75.0 72.0 to 78.0 4
400 112.5 109.5 to 115.5 5
500 150.0 147.0 to >150 5
500 150.0 147.0 to >150 4
400 112.5 109.5 to 115.5 3
300 75.0 72.0 to 78.0 2
200 37.5 34.5 to 40.5 1
100 0.0
<0 to 3.0 M&TE ID DESCRIPTION Precision voltmeter Precision test resistor 6.6.11 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 58 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.6.12 Using Table 6-39, perform a calibration test of T0411A.
Table 6-39 INPUT (mvdc)
OUTPUT (%)
T0411A Accuracy: +/- 1.5%
TM-406D DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 0.0 1.5 to 1.5 2
200 37.5 36.0 to 39.0 3
300 75.0 73.5 to 76.5 4
400 112.5 111.0 to 114.0 5
500 150.0 148.5 to 151.5 M&TE ID DESCRIPTION Precision voltmeter Precision test resistor 6.6.13 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 59 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note Recorder TR-405A is calibrated in SP-47-011A.
6.6.14 Using Table 6-40, check TR-405A (red pen).
Table 6-40 INPUT (mvdc)
OUTPUT (%)
TR-405A 4255301 Accuracy: +/- 0.5%
TM-406D DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
300 75.0 74.5 to 75.5 M&TE ID DESCRIPTION Precision voltmeter Precision test resistor 6.6.15 At TM-406D, remove all test equipment.
6.6.16 At TM-406D, connect the signal cord set.
6.6.17 At TM-402B, remove the current calibrator.
6.6.18 At TM-402B, connect the signal cord set.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 60 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.6.19 At the PRESS. PRESS. (430) signal injection test jacks, connect an analog simulator.
6.6.20 At the following test point jacks, connect a precision voltmeter:
6.6.20.1 PRESS. PRESS.
(430) _______
6.6.20.2 TAVG MA 6.6.20.3 TAVG VOLTS 6.6.20.4 TSP1 6.6.21 Connect data acquisition device to the following test point jacks:
6.6.21.1 Channel 1 TAVG MA _______
6.6.21.2 Channel 2 TSP1 _______
6.6.22 Notify Shift Manager/Unit Supervisor ICCMS Train B will be INOPERABLE. _______
(SM/US) 6.6.23 Notify the Control Room Operators that performing the following step causes the ICCMS B display to start flashing.
6.6.24 Place the PRESS. PRESS. (430) signal injection switch to TEST (up).
6.6.25 At the TAVG signal injection test jacks, connect a ramp generator.
6.6.26 Place the TAVG signal injection switch to TEST (up).
6.6.27 Adjust the voltage sources at QU and QL for outputs of 0.00 vdc.
Note For Step 6.6.28, the Fluke 45 precision voltmeter setting is 300 mvdc medium resolution.
6.6.28 Adjust the analog simulator at PRESS. PRESS. (430) for a PRESS. PRESS. (430) output of 40.40 mvdc.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 61 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.6.29 Use the following guidelines to adjust the data acquisition device:
Table 6-41 Range 1 600.0 mvdc Offset 0.00 vdc Range 2 600.0 mvdc Offset 0.00 vdc Total time 26 secs Pretrigger 2.0 secs for up ramp 4.0 secs for down ramp Trigger level 132 mvdc + LEVEL for up ramp 470 mvdc LEVEL for down ramp Y axis 30 divisions X axis 13 divisions Note Steps 6.6.30 and 6.6.31 may be performed as many times as needed.
6.6.30 Perform a dynamic test of TM-402B by applying an input ramp from 121 mvdc to 500 mvdc at a rate of 10 mvdc/sec.
6.6.31 Perform a dynamic test of TM-402B by applying an input ramp from 500 mvdc to 121 mvdc at a rate of 10 mvdc/sec.
6.6.32 Remove the ramp generator.
6.6.33 At the TAVG signal injection test jacks, connect a step function generator and current calibrator.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 62 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.6.34 Use the following guidelines to adjust the data acquisition device:
Table 6-42 Range 1 320.0 mvdc Offset 0.14 vdc for up step 0.26 vdc for down step Range 2 320.0 mvdc Offset 0.14 vdc for up step 0.26 vdc for down step Total time 26 secs Pretrigger 1.0 sec for up step 1.0 sec for down step Trigger level 315 mvdc + LEVEL for up step 315 mvdc LEVEL for down step Y axis 32 divisions X axis 13 divisions Note Steps 6.6.36 and 6.6.38 may be performed as many times as needed.
6.6.35 Adjust the analog simulator at PRESS. PRESS. (430) for PRESS. PRESS. (430) output of 147 mvdc.
6.6.36 Perform a dynamic test of TM-402B by applying an input step change from 308 mvdc to 328 mvdc.
6.6.37 Adjust the analog simulator at PRESS. PRESS. (430) for PRESS. PRESS. (430) output of 40 mvdc.
6.6.38 Perform a dynamic test of TM-402B by applying an input step change from 328 mvdc to 308 mvdc.
6.6.39 Compare the traces with the Kewaunee LEAD/LAG CAL book for TM-402B.
6.6.40 IF the traces are UNSAT, THEN calibrate the TM-402B dynamics AND repeat Steps 6.6.25 through 6.6.39.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 63 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.6.41 Attach the traces to this procedure.
6.6.42 Remove the data acquisition device.
6.6.43 Remove the step function generator.
6.6.44 Adjust the current calibrator at TAVG for a TAVG MA output of 205.28 mvdc**.
Note Dynamic compensation is present. Allow time for the output to stabilize.
Note If performing this procedure as post SP-47-288B, Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White)
Calibration performance, the TSP1 value will be 7% low with a TAVG of 572ºF (308 mvdc), PRESS. PRESS. of 2235 psig (147 mvdc) and NO f(l) (100 mvdc). TM-402B should be adjusted for 118.25% (415.3 mvdc) using the K1 potentiometer. K1 (as labeled on the box) is equivalent to KSB (as indicated on the manufacturers drawing).
6.6.45 Using Table 6-43, perform a calibration test of TM-402B.
Table 6-43 INPUT (mvdc*)
OUTPUT (mvdc**)
TM-402B 4892711 TSP1 Accuracy: +/- 2.0 mvdc PRESS. PRESS.
(430)
DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
40.0 415.3 413.3 to 417.3 2
83.0 456.6 454.6 to 458.6 3
128.0 499.8 497.8 to 501.8 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
Fluke 45 precision voltmeter**
Fluke 45 precision voltmeter**
- 300 mvdc medium resolution
- 1000 mvdc slow resolution SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 64 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.6.46 Are all Final Data entries within the acceptance range?
Yes
No 6.6.47 Adjust the current calibrator at TAVG for a TAVG MA output of 260 mvdc**. _______
Note Dynamic compensation is present. Allow time for the output to stabilize.
6.6.48 Using Table 6-44, perform a calibration test of TM-402B.
Table 6-44 INPUT (mvdc*)
OUTPUT (mvdc**)
TM-402B 4892711 TSP1 Accuracy: +/- 2.0 mvdc PRESS. PRESS.
(430)
DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
40 360.6 358.6 to 362.6 2
120 437.4 435.4 to 439.4 3
185 499.8 497.8 to 501.8 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
Fluke 45 precision voltmeter**
Fluke 45 precision voltmeter**
- 300 mvdc medium resolution
- 1000 mvdc slow resolution 6.6.49 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 65 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.6.50 Adjust the current calibrator at TAVG for a TAVG MA output of 340 mvdc**. _______
Note Dynamic compensation is present. Allow time for the output to stabilize.
6.6.51 Using Table 6-45, perform a calibration test of TM-402B.
Table 6-45 INPUT (mvdc*)
OUTPUT (mvdc**)
TM-402B 4892711 TSP1 Accuracy: +/- 2.0 mvdc PRESS. PRESS.
(430)
DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
40 280.6 278.6 to 282.6 2
110 347.8 345.8 to 349.8 3
180 415.0 413.0 to 417.0 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
Fluke 45 precision voltmeter**
Fluke 45 precision voltmeter**
- 300 mvdc medium resolution
- 1000 mvdc slow resolution 6.6.52 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 66 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.6.53 Adjust the current calibrator at TAVG for a TAVG MA output of 420 mvdc**. _______
Note Dynamic compensation is present. Allow time for the output to stabilize.
6.6.54 Using Table 6-46, perform a calibration test of TM-402B.
Table 6-46 INPUT (mvdc*)
OUTPUT (mvdc**)
TM-402B 4892711 TSP1 Accuracy: +/- 2.0 mvdc PRESS. PRESS.
(430)
DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
40 200.6 198.6 to 202.6 2
110 267.8 265.8 to 269.8 3
180 335.0 333.0 to 337.0 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
Fluke 45 precision voltmeter**
Fluke 45 precision voltmeter**
- 300 mvdc medium resolution
- 1000 mvdc slow resolution 6.6.55 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 67 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.6.56 Adjust the current calibrator at TAVG for a TAVG MA output of 500 mvdc**. _______
Note Dynamic compensation is present. Allow time for the output to stabilize.
6.6.57 Using Table 6-47, perform a calibration test of TM-402B.
Table 6-47 INPUT (mvdc*)
OUTPUT (mvdc**)
TM-402B 4892711 TSP1 Accuracy: +/- 2.0 mvdc PRESS. PRESS.
(430)
DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
40 120.6 118.6 to 122.6 2
110 187.8 185.8 to 189.8 3
180 255.0 253.0 to 257.0 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
Fluke 45 precision voltmeter**
Fluke 45 precision voltmeter**
- 300 mvdc medium resolution
- 1000 mvdc slow resolution 6.6.58 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 68 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.6.59 Adjust the analog simulator at PRESS. PRESS. (430) for a PRESS. PRESS. (430) output of 200 mvdc*.
6.6.60 Adjust the current calibrator at TAVG for a TAVG MA output of 274.2 mvdc**.
6.6.61 Adjust the voltage source at QU for a QU output of 0.00 vdc.
Note Use the voltage source at QL to vary the input.
6.6.62 Using Table 6-48, perform a calibration test of TM-402B.
Table 6-48 INPUT (mvdc**)
OUTPUT (mvdc**)
TM-402B 4892711 TSP1 Accuracy: +/- 2.0 mvdc Q
DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100.0 500.0 498.0 to 502.0 2
200.0 400.0 398.0 to 402.0 3
300.0 300.0 298.0 to 302.0 4
400.0 200.0 198.0 to 202.0 5
500.0 100.0 98.0 to 102.0 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
Fluke 45 precision voltmeter**
Fluke 45 precision voltmeter**
- 300 mvdc medium resolution
- 1000 mvdc slow resolution 6.6.63 Are all Final Data entries within the acceptance range?
Yes
No 6.6.64 IF adjustments were made to TM-402B temperature gain input, THEN perform dynamic test steps 6.6.27 through 6.6.40, otherwise N/A this step.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 69 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.6.65 Adjust the voltage sources at QU and QL for outputs of 8.33 vdc.
6.6.66 Adjust the current calibrator at TAVG for a TAVG MA output of 308.0 mvdc. _______
6.6.67 Adjust the analog simulator at PRESS. PRESS. (430) for a PRESS. PRESS. (430) output of >147 mvdc.
6.6.68 At T LAG test point jacks, connect a precision voltmeter.
6.6.69 Adjust the voltage source at TT-402B for a TCL output of 2.00 vdc.
6.6.70 Adjust the voltage source at TT-402A for a T LAG output of 7.306 vdc.
6.6.71 Using Table 6-49, perform a calibration test by lowering the analog simulator output at PRESS. PRESS. (430) until the ROD STOP (406D) bistable proving lamp is OFF.
Table 6-49 Overtemperature Rod Stop TC-406D 4857105 TSP1 Accuracy: +/- 2.0 mvdc SETPOINT DESIRED AS FOUND ACCEPTANCE RANGE FINAL Set (mvdc) 428.7 426.7 to 430.7 Reset (mvdc) 432.7 430.7 to 434.7 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
Precision voltmeter
- 1000 mvdc slow resolution SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 70 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.6.72 Using Table 6-50, perform a calibration test by lowering the analog simulator output at PRESS. PRESS. (430) until the OVER TEMP TRIP (406C) bistable proving lamp is OFF.
Table 6-50 Overtemperature Trip TC-406C 4857105 TSP1 Accuracy: +/- 2.0 mvdc SETPOINT DESIRED AS FOUND ACCEPTANCE RANGE FINAL Set (mvdc) 415.3 413.3 to 417.3 Reset (mvdc) 419.3 417.3 to 421.3 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
Precision voltmeter
- 1000 mvdc slow resolution 6.6.73 In Relay Rack RR-114, place the PRESS. PRESS. (430) signal injection switch to NORMAL (down).
6.6.74 At the following test point jacks, remove the precision voltmeter:
6.6.74.1 TSP1 6.6.74.2 PRESS. PRESS.
(430) _______
6.6.75 At the PRESS. PRESS. (430) signal injection test jacks, remove the analog simulator.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 71 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.7 Pressurizer Pressure Loop 430 6.7.1 Using Table 6-51, at power supply PQ-430, verify the power supply load potentiometer.
Table 6-51 Power Supply Load Adjustment PQ-430 4840101 Relay Rack RR-114 Accuracy: +/- 25 ohms SETPOINT DESIRED AS FOUND ACCEPTANCE RANGE FINAL Set (ohms) 0 0 to 25 6.7.2 In Relay Rack RR-114, connect data acquisition device to the following test points:
6.7.2.1 Channel 1 PRESS. PRESS. (430) _______
6.7.2.2 Channel 2 COMP. PRESS. (430) _______
6.7.3 In Relay Rack RR-114, place the PRESS. PRESS. (430) signal injection switch to TEST (up).
6.7.4 At PQ-430, remove the signal cord set.
6.7.5 At the PRESS. PRESS. (430) signal injection test jacks, connect a jumper.
Concurrent Verification _______
6.7.6 At the PQ-430 cord set, pins A(+) and U(), connect a ramp generator.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 72 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.7.7 Use the following guideline to adjust the data acquisition device:
Table 6-52 UP STEP DOWN STEP Range 1 600.0 mvdc 600.0 mvdc Offset 0.00 mvdc 0.00 mvdc Range 2 600.0 mvdc 600.0 mvdc Offset 0.10 mvdc 0.06 mvdc Total time 44 secs 44 secs Pretrigger 4 secs 2 secs Trigger level 45 mvdc ABOVE 190 mvdc BELOW Y axis 30 divisions 30 divisions X axis 24 divisions 24 divisions 6.7.8 Perform a dynamic test of PM-430C by applying an input ramp from 40 mvdc to 200 mvdc at a rate of 4 mvdc/sec.
6.7.9 Perform a dynamic test of PM-430C by applying an input ramp from 200 mvdc to 40 mvdc at a rate of 4 mvdc/sec.
6.7.10 Remove the ramp generator.
6.7.11 At the PRESS. PRESS. (430) signal injection test jacks, remove the jumper.
Independent Verification _______
6.7.12 At the PRESS. PRESS. (430) signal injection test jacks, connect an analog simulator.
6.7.13 At PQ-430, connect the cord set.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 73 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.7.14 Use the following guidelines to adjust the data acquisition device:
Table 6-53 UP STEP DOWN STEP Range 1 200.0 mvdc 200.0 mvdc Offset 0.14 mvdc 0.00 mvdc Range 2 600.0 mvdc 600.0 mvdc Offset 0.10 mvdc 0.10 mvdc Total time 44 secs 44 secs Pretrigger 6 secs 6 secs Trigger level 45 mvdc ABOVE 190 mvdc BELOW Y axis 30 divisions 30 divisions X axis 24 divisions 24 divisions 6.7.15 Perform a dynamic test of PM-430C by applying an input step change from 40 mvdc to 48 mvdc.
6.7.16 Perform a dynamic test of PM-430C by applying an input step change from 200 mvdc to 192 mvdc.
Note The 8 mvdc step input used for a 4 to 20 madc loop corresponds to a 20 mvdc step for a 10 to 50 madc loop. Multiply by 2.5 to obtain the required values.
6.7.17 Compare the traces with the Kewaunee LEAD/LAG CAL book for PM-430C.
6.7.18 IF the traces are UNSAT, THEN calibrate the PM-430C dynamics and repeat Steps 6.7.4 through 6.7.17.
6.7.19 Attach the traces to this procedure.
6.7.20 Remove the data acquisition device.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 74 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.7.21 At the PRESS. PRESS. (430) test point jacks, connect a precision voltmeter.
6.7.22 At the COMP. PRESS. (430) test point jacks, connect a precision voltmeter.
Note Dynamic compensation is used. Allow time for the output to stabilize.
6.7.23 Using Table 6-54, perform a calibration test of PM-430C.
Table 6-54 Input (mvdc*)
Output (mvdc**)
PM-430C 4840104 COMP. PRESS. (430)
Accuracy: +/- 2.0 mvdc PRESS. PRESS.
(430)
DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
40 100.0 98.0 to 102.0 2
80 200.0 198.0 to 202.0 3
120 300.0 298.0 to 302.0 4
160 400.0 398.0 to 402.0 5
200 500.0 498.0 to 502.0 5
200 500.0 498.0 to 502.0 4
160 400.0 398.0 to 402.0 3
120 300.0 298.0 to 302.0 2
80 200.0 198.0 to 202.0 1
40 100.0 98.0 to 102.0 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
Fluke 45 precision voltmeter**
- 300 mvdc medium resolution
- 1000 mvdc slow resolution 6.7.24 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 75 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.7.25 At PM-430C, remove the signal cord set.
6.7.26 At the PM-430C cord set, pins W(+) and X(), connect a current calibrator.
Note The desired values for Table 6-55 are based on Calculation Number C10818-4 Rev.1.
6.7.27 Using Table 6-55, perform a calibration test by lowering the current calibrator output at PM-430C until the LO PRESS. TRIP (430H) bistable proving lamp is OFF.
Table 6-55 PRZR Low Pressure RX Trip (1904 psig)
PC-430H 4840105 COMP. PRESS. (430)
Accuracy: +/- 2.0 mvdc SETPOINT DESIRED AS FOUND ACCEPTANCE RANGE FINAL Set (mvdc) 202.0 200.0 to 204.0 Reset (mvdc) 206.0 204.0 to 208.0 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
- 300 mvdc medium resolution 6.7.28 At the PM-430C cord set, remove the current calibrator.
6.7.29 At PM-430C, connect the signal cord set.
6.7.30 At the COMP. PRESS. (430) test point jacks, remove the precision voltmeter. _______
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 76 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note The desired values for Table 6-56 are based on Calculation Number C10818-1 Rev.1.
6.7.31 Using Table 6-56, perform a calibration test by raising the analog simulator output at PRESS. PRESS. (430) until the HI PRESS. TRIP (430A) bistable proving lamp is OFF.
Table 6-56 PRZR High Pressure Rx Trip (2377 psig)
PC-430A 4840102 PRESS. PRESS. (430)
Accuracy: +/- 0.8 mvdc SETPOINT DESIRED AS FOUND ACCEPTANCE RANGE FINAL Set (mvdc) 175.4 174.6 to 176.2 Reset (mvdc) 173.8 173.0 to 174.6 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
- 300 mvdc medium resolution Note The desired values for Table 6-57 are based on Calculation Number C10818-3 Rev.1.
6.7.32 Using Table 6-57, perform a calibration test by raising the analog simulator output at PRESS. PRESS. (430) until the UNBLOCK S.I. (430F) bistable proving lamp is OFF.
Table 6-57 PRZR High Pressure Unblock SI (1985 psig)
PC-430F 4840103 PRESS. PRESS. (430)
Accuracy: +/- 0.8 mvdc SETPOINT DESIRED AS FOUND ACCEPTANCE RANGE FINAL Set (mvdc) 97.0 96.2 to 97.8 Reset (mvdc) 95.4 94.6 to 96.2 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
- 300 mvdc medium resolution SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 77 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note The desired values for Table 6-58 are based on Calculation Number C10818-2 Rev.1.
6.7.33 Using Table 6-58, perform a calibration test by lowering the analog simulator output at PRESS. PRESS. (430) until the S.I. (430E) bistable proving lamp is OFF.
Table 6-58 PRZR Low Pressure Safety Injection (1830 psig)
PC-430E 4840103 PRESS. PRESS. (430)
Accuracy: +/- 0.8 mvdc SETPOINT DESIRED AS FOUND ACCEPTANCE RANGE FINAL Set (mvdc) 66.0 65.2 to 66.8 Reset (mvdc) 67.6 66.8 to 68.4 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
- 300 mvdc medium resolution SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 78 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.7.34 In Relay Rack RR-114, TP/PM430A, connect a precision voltmeter.
6.7.35 Using Table 6-59, perform a calibration test of PM-430A.
Table 6-59 Input (mvdc*)
Output (mvdc**)
PM-430A 4840106 TP/PM430A Accuracy: +/- 2.0 mvdc PRESS. PRESS.
(430)
DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
40 100.0 98.0 to 102.0 2
80 200.0 198.0 to 202.0 3
120 300.0 298.0 to 302.0 4
160 400.0 398.0 to 402.0 5
200 500.0 498.0 to 502.0 5
200 500.0 498.0 to 502.0 4
160 400.0 398.0 to 402.0 3
120 300.0 298.0 to 302.0 2
80 200.0 198.0 to 202.0 1
40 100.0 98.0 to 102.0 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
Fluke 45 precision voltmeter**
- 300 mvdc medium resolution
- 1000 mvdc slow resolution 6.7.36 Are all Final Data entries within the acceptance range?
Yes
No 6.7.37 At the PRESS. PRESS. (430) test point jacks, remove the precision voltmeter. _______
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 79 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.7.38 In Relay Rack RR-105, TP/PM430D, connect a precision voltmeter.
6.7.39 Using Table 6-60, perform a calibration test of PM-430D.
Table 6-60 Input (mvdc)
Output (mvdc)
PM-430D 4840110 TP/PM430D Accuracy: +/- 2.0 mvdc TP/PM430A DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 100.0 98.0 to 102.0 2
200 200.0 198.0 to 202.0 3
300 300.0 298.0 to 302.0 4
400 400.0 398.0 to 402.0 5
500 500.0 498.0 to 502.0 5
500 500.0 498.0 to 502.0 4
400 400.0 398.0 to 402.0 3
300 300.0 298.0 to 302.0 2
200 200.0 198.0 to 202.0 1
100 100.0 98.0 to 102.0 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
Fluke 45 precision voltmeter*
- 1000 mvdc slow resolution 6.7.40 Are all Final Data entries within the acceptance range?
Yes
No 6.7.41 In Relay Rack RR-187, at the ICCMS Train B front panel display, enter test mode by pressing the TEST pushbutton.
6.7.42 Using the LEVEL/MARGIN and ACK pushbuttons on the front panel display, select Test 16.
6.7.43 Select Channel 33.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 80 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.7.44 Using Table 6-61, perform a calibration test of ICCMS digital readout for Channel 33.
Table 6-61 Input (mvdc)
Output (psig)
Channel 33 Accuracy: +/- 4 psig TP/PM430A DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 1700 1696 to 1704 2
200 1900 1896 to 1904 3
300 2100 2096 to 2104 4
400 2300 2296 to 2304 5
500 2500 2496 to 2504 M&TE ID DESCRIPTION Precision voltmeter 6.7.45 Are all Final Data entries within the acceptance range?
Yes
No 6.7.46 Exit test 16 by pressing the ACK pushbutton.
6.7.47 Return ICCMS Train B to service by pressing the TEST pushbutton.
Concurrent Verification _______
6.7.48 At TP/PM430A, remove the precision voltmeter.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 81 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.7.49 In Relay Rack RR-105, at PM-430B, remove the signal cord set.
Note Figure 4 shows the I&C output test connector 6.7.50 At PM-430B, connect an I&C output test connector and 10 ohm precision test resistor.
6.7.51 At PM-430B, connect the signal cord set.
6.7.52 At PM-430B, at the I&C output test connector, connect a precision voltmeter. _______
Figure 4 CORD SET 10 ohm test resistor OUTPUT TEST CONNECTOR CURRENT TO CURRENT OR VOLTAGE TO CURRENT CONVERTER SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 82 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note Table 6-62, Table 6-63, and Table 6-64 may be performed concurrently.
6.7.53 Using Table 6-62, perform a calibration test of PM-430B.
Table 6-62 Input (mvdc)
Output (mvdc)
PM-430B 4840107 PM-430B Accuracy: +/- 2.0 mvdc TP/PM430D DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 100.0 98.0 to 102.0 2
200 200.0 198.0 to 202.0 3
300 300.0 298.0 to 302.0 4
400 400.0 398.0 to 402.0 5
500 500.0 498.0 to 502.0 5
500 500.0 498.0 to 502.0 4
400 400.0 398.0 to 402.0 3
300 300.0 298.0 to 302.0 2
200 200.0 198.0 to 202.0 1
100 100.0 98.0 to 102.0 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
Fluke 45 precision voltmeter*
Precision test resistor
- 1000 mvdc slow resolution 6.7.54 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 83 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.7.55 Using Table 6-63, perform a calibration test of PI-430.
Table 6-63 Input (mvdc)
Output (psig)
PI-430 4122202 Accuracy: +/- 16 psig TP/PM430D DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 1700
<1700 to 1716 2
200 1900 1884 to 1916 3
300 2100 2084 to 2116 4
400 2300 2284 to 2316 5
500 2500 2484 to >2500 5
500 2500 2484 to >2500 4
400 2300 2284 to 2316 3
300 2100 2084 to 2116 2
200 1900 1884 to 1916 1
100 1700
<1700 to 1716 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
- 1000 mvdc slow resolution 6.7.56 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 84 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.7.57 Using Table 6-64, perform a calibration test of P0430A.
Table 6-64 Input (mvdc)
Output (psig)
P0430A Accuracy: +/- 8 psig PM-430B DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 1700 1692 to 1708 2
200 1900 1892 to 1908 3
300 2100 2092 to 2108 4
400 2300 2292 to 2308 5
500 2500 2492 to 2508 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
Precision test resistor
- 1000 mvdc slow resolution 6.7.58 Are all Final Data entries within the acceptance range?
Yes
No 6.7.59 At PM-430B, remove the I&C test connector, precision voltmeter, and test resistor.
6.7.60 At PM-430B, connect the cord set.
6.7.61 At Recorder 42301, select CAL START message.
6.7.62 At Mechanical Control Console C, have a Control Room Operator place PRZR PRESSURE RECORDER INPUT SELECTOR switch (ES-46325) to position 2.
2 _______
(Operator)
Concurrent Verification _______
(Operator)
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 85 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note Recorder PR-429 is calibrated in SP-47-011A.
6.7.63 Using Table 6-65, check PR-429 (red pen).
Table 6-65 INPUT (mvdc)
OUTPUT (psig)
PR-429 42301 Accuracy: +/- 1.6 psig TM/PM430D DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
300 2100.0 2098.4 to 2101.6 M&TE ID DESCRIPTION Precision voltmeter Note Performing the following step prevents PR-2B/CV-31109 PRZR PORV from operating.
6.7.64 At Mechanical Control Console C, have a Control Room Operator verify PR-2B/CV-31109 PRZR PORV control switch (ES-46414) to CLOSE.
CLOSE _______
(Operator)
Concurrent Verification _______
(Operator) 6.7.65 Notify the Control Room Operator, IF desired, operate Pressurizer Pressure controls in MANUAL using Operations procedure N-RC-36C, Pressurizer Pressure Control before transferring the PRZR PRESSURE CONTROL CHANNEL SELECTOR switch (Step 6.7.66).
(Operator) 6.7.66 At Mechanical Control Console C, have a Control Room Operator place PRZR PRESSURE CONTROL CHANNEL SELECTOR switch (ES-46324) to position 2-3.
2-3 _______
(Operator)
Concurrent Verification _______
(Operator)
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 86 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.7.67 Notify the Control Room Operator, IF desired, the controllers may be placed to AUTO.
(Operator)
Concurrent Verification _______
(Operator) 6.7.68 In Relay Rack RR-105, TB-PLPP-W, terminals 1 and 2, connect an AC voltmeter.
6.7.69 Using Table 6-66, perform a calibration test by raising the analog simulator output at PRESS. PRESS. (430) AND monitoring the output at TB-PLPP-W terminals 1 and 2.
Table 6-66 PRZR Pressure Relief Valve 2B (2335 psig)
PC-430B 4840108 TP/PM430D Accuracy: +/- 2.0 mvdc SETPOINT DESIRED AS FOUND ACCEPTANCE RANGE FINAL Set (mvdc) 417.5 415.5 to 419.5 Reset (mvdc) 407.5 405.5 to 409.5 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
- 1000 mvdc slow resolution 6.7.70 Remove the AC voltmeter.
6.7.71 At Relay Rack RR-105, TB-PLPP-W, terminals 3 and 4, connect an AC voltmeter.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 87 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.7.72 Using Table 6-67, perform a calibration test by raising the analog simulator output at PRESS. PRESS. (430) AND monitoring the output at TB-PLPP-W terminals 3 and 4.
Table 6-67 PRZR Pressure High (2310 psig)
PC-430C 4840109 TP/PM430D Accuracy: +/- 2.0 mvdc SETPOINT DESIRED AS FOUND ACCEPTANCE RANGE FINAL Set (mvdc) 405.0 403.0 to 407.0 Reset (mvdc) 401.0 399.0 to 403.0 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
- 1000 mvdc slow resolution 6.7.73 Check annunciator (47042C) PRESSURIZER PRESSURE HIGH alarms at setpoint.
6.7.74 Check SER (940) PRESSURIZER PRESSURE HIGH alarms at setpoint.
6.7.75 Remove the AC voltmeter.
6.7.76 In Relay Rack RR-114, place the PRESS. PRESS. (430) signal injection switch to NORMAL (down).
6.7.77 Remove the analog simulator.
6.7.78 At TP/PM430D, check loop integrity by measuring a voltage that is consistent with plant conditions.
mvdc _______
6.7.79 At TP/PM430D, remove the precision voltmeter.
6.7.80 At Mechanical Control Console C, have a Control Room Operator place PR-2B/CV-31109 PRZR PORV control switch (ES-46414) to the desired position AND circle that position.
CLOSE / AUTO / OPEN _______
(Operator)
Concurrent Verification _______
(Operator)
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 88 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.7.81 Notify Shift Manager/Unit Supervisor, ICCMS Train B is OPERABLE.
(SM/US) 6.8 F(TAVG) 6.8.1 Connect data acquisition device to the following test point jacks:
6.8.1.1 Channel 1 TAVG MA _______
6.8.1.2 Channel 2 F(TAVG) _______
6.8.2 At the TAVG signal injection test jacks, remove the current calibrator.
6.8.3 At the TAVG signal injection test jacks, connect a ramp generator.
6.8.4 Use the following guidelines to adjust the data acquisition device:
Table 6-68 Range 1 600.0 mvdc Offset 0.00 mvdc Range 2 600.0 mvdc Offset 0.00 mvdc Total time 54 secs Pretrigger 3.0 secs Trigger level 110 mvdc + LEVEL Y axis 30 divisions X axis 27 divisions 6.8.5 Perform a dynamic test of TM-402O by applying an input ramp from 100 mvdc to 500 mvdc at a rate of 10 mvdc/sec.
6.8.6 Remove the ramp generator.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 89 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.8.7 At the TAVG signal injection test jacks, connect a step function current calibrator.
6.8.8 Use the following guidelines to adjust the data acquisition device:
Table 6-69 Range 1 300.0 mvdc Offset 0.00 vdc Range 2 150.0 mvdc Offset 0.05 vdc Total time 54 secs Pretrigger 2.0 secs Trigger level 295 mvdc + LEVEL Y axis 30 divisions X axis 27 divisions 6.8.9 Perform a dynamic test of TM-402O by applying an input step change from 287 mvdc to 307 mvdc.
6.8.10 Compare the traces with the Kewaunee LEAD/LAG CAL book for TM-402O.
6.8.11 IF the traces are UNSAT, THEN calibrate the TM-402O dynamics AND repeat Steps 6.8.2 through 6.8.10.
6.8.12 Attach the traces to this procedure.
6.8.13 Remove the data acquisition device.
6.8.14 At F(TAVG) test point jacks, connect a precision voltmeter.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 90 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note Dynamic compensation is present. Allow time for the output to stabilize.
6.8.15 Using Table 6-70, perform a calibration test of TM-402O.
Table 6-70 INPUT (mvdc)
OUTPUT (mvdc)
TM-402O 4892706 F(TAVG)
Accuracy: +/- 2.0 mvdc TAVG MA DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 100.0 98.0 to 102.0 2
200 100.0 98.0 to 102.0 3
308 100.0 98.0 to 102.0 4
340 102.2 100.2 to 104.2 5
420 107.7 105.7 to 109.7 6
460 110.4 108.4 to 112.4 7
500 113.2 111.2 to 115.2 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter 6.8.16 Are all Final Data entries within the acceptance range?
Yes
No 6.8.17 Place the TAVG signal injection switch to NORMAL (down).
6.8.18 At the TAVG signal injection test jacks, remove the current calibrator.
6.8.19 At TAVG MA test point jacks, remove the precision voltmeter.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 91 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.9 Overpower T Setpoint 6.9.1 In Relay Rack RR-114, TM-402S, remove the signal cord set.
Note Figure 5 shows the I&C output test connector.
6.9.2 At TM-402S, connect an I&C output test connector and 10 ohm precision test resistor.
6.9.3 At TM-402S, connect the signal cord set.
6.9.4 At TM-402S, at the I&C output test connector, connect a precision voltmeter.
6.9.5 At TM-402V, remove the signal cord set.
6.9.6 At pins W(+) and X(), connect a current calibrator.
6.9.7 At TSP2 test point jacks, connect a precision voltmeter.
Figure 5 CORD SET 10 ohm test resistor OUTPUT TEST CONNECTOR CURRENT TO CURRENT OR VOLTAGE TO CURRENT CONVERTER SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 92 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note Table 6-71, Table 6-72, Table 6-73, and Table 6-74 may be performed concurrently.
6.9.8 Using Table 6-71, perform a calibration test of TM-402S.
Table 6-71 INPUT (mvdc)
OUTPUT (mvdc)
TM-402S 4892709 TM-402S Accuracy: +/- 2.0 mvdc TSP2 DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 100.0 98.0 to 102.0 2
200 200.0 198.0 to 202.0 3
300 300.0 298.0 to 302.0 4
400 400.0 398.0 to 402.0 5
500 500.0 498.0 to 502.0 5
500 500.0 498.0 to 502.0 4
400 400.0 398.0 to 402.0 3
300 300.0 298.0 to 302.0 2
200 200.0 198.0 to 202.0 1
100 100.0 98.0 to 102.0 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter Precision test resistor 6.9.9 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 93 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.9.10 Using Table 6-72, perform a calibration test of TI-406C.
Table 6-72 INPUT (mvdc)
OUTPUT (%)
TI-406C 4121703 Accuracy: +/- 3%
TM-402S DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 0.0
<0 to 3.0 2
200 37.5 34.5 to 40.5 3
300 75.0 72.0 to 78.0 4
400 112.5 109.5 to 115.5 5
500 150.0 147.0 to >150 5
500 150.0 147.0 to >150 4
400 112.5 109.5 to 115.5 3
300 75.0 72.0 to 78.0 2
200 37.5 34.5 to 40.5 1
100 0.0
<0 to 3.0 M&TE ID DESCRIPTION Precision voltmeter Precision test resistor 6.9.11 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 94 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.9.12 Using Table 6-73, perform a calibration test of T0408A.
Table 6-73 INPUT (mvdc)
OUTPUT (%)
T0408A Accuracy: +/- 1.5%
TM-402S DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100 0.0 1.5 to 1.5 2
200 37.5 36.0 to 39.0 3
300 75.0 73.5 to 76.5 4
400 112.5 111.0 to 114.0 5
500 150.0 148.5 to 151.5 M&TE ID DESCRIPTION Precision voltmeter Precision test resistor 6.9.13 Are all Final Data entries within the acceptance range?
Yes
No SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 95 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White)
Note Recorder TR-405A is calibrated in SP-47-011A.
6.9.14 Using Table 6-74, check TR-405A (blue pen).
Table 6-74 INPUT (mvdc)
OUTPUT (%)
TR-405A 4255303 Accuracy: +/- 0.5%
TM-402S DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
300 75.0 74.5 to 75.5 M&TE ID DESCRIPTION Precision voltmeter Precision test resistor 6.9.15 At TM-402S, remove all test equipment.
6.9.16 At TM-402S, connect the signal cord set.
6.9.17 At TM-402V, remove the current calibrator.
6.9.18 At TM-402V, connect the signal cord set.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 96 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.9.19 At the F(TAVG) signal injection test jacks, connect a current calibrator.
6.9.20 Place the F(TAVG) signal injection switch to TEST (up).
Note If performing this procedure as post SP-47-288B, Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White)
Calibration performance, the TSP2 value will be 7% low with a TAVG of 572ºF (308 mvdc). TM-402V should be adjusted for 108.25% (388.7 mvdc) using the BIAS potentiometer.
6.9.21 Using Table 6-75, perform a calibration test of TM-402V.
Table 6-75 INPUT (mvdc)
OUTPUT (mvdc)
TM-402V 4892707 TSP2 Accuracy: +/- 2.0 mvdc F(TAVG)
DESIRED AS FOUND ACCEPTANCE RANGE FINAL 1
100.0 388.7 386.7 to 390.7 2
101.9 386.8 384.8 to 388.8 3
113.2 375.5 373.5 to 377.5 4
121.4 367.3 365.3 to 369.3 M&TE ID DESCRIPTION Precision voltmeter Precision voltmeter
- 1000 mvdc slow resolution 6.9.22 Are all Final Data entries within the acceptance range?
Yes
No 6.9.23 Adjust the TCL voltage source for a TCL output of 2.00 vdc.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 97 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.9.24 Using the THL voltage source, adjust the T LAG output to 6.688 vdc.
6.9.25 Using Table 6-76, perform a calibration test by raising the current calibrator output at F(TAVG) until the ROD STOP (406B) bistable proving lamp is OFF. _______
Table 6-76 Overpower Rod Stop TC-406B 4857107 TSP2 Accuracy: +/- 2.0 mvdc SETPOINT DESIRED AS FOUND ACCEPTANCE RANGE FINAL Set (mvdc) 396.7 394.7 to 398.7 Reset (mvdc) 400.7 398.7 to 402.7 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
Precision voltmeter
- 1000 mvdc slow resolution 6.9.26 Using Table 6-77, perform a calibration test by raising the current calibrator output at F(TAVG) until the OVER POWER TRIP (406A) bistable proving lamp is OFF.
Table 6-77 Overpower Trip TC-406A 4857107 TSP2 Accuracy: +/- 2.0 mvdc SETPOINT DESIRED AS FOUND ACCEPTANCE RANGE FINAL Set (mvdc) 388.7 386.7 to 390.7 Reset (mvdc) 392.7 390.7 to 394.7 M&TE ID DESCRIPTION Fluke 45 precision voltmeter*
Precision voltmeter
- 1000 mvdc slow resolution 6.9.27 Place the F(TAVG) signal injection switch to NORMAL (down).
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 98 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.9.28 At the F(TAVG) signal injection test jacks, remove the current calibrator.
6.9.29 At F(TAVG), test point jacks, remove the precision voltmeter.
6.9.30 At TSP2 test point jacks, remove the precision voltmeter.
6.10 Restoration 6.10.1 Place the following signal injection switches to NORMAL (down):
6.10.1.1 QU 6.10.1.2 QL 6.10.2 At TT-402A, remove the voltage source.
6.10.3 At TT-402A, connect the signal cord set.
6.10.4 Restore power to TT-402A by plugging in the power cord AND record the time.
________ time _______
6.10.5 At TT-402B, remove the voltage source.
6.10.6 At TT-402B, connect the signal cord set.
6.10.7 Restore power to TT-402B by plugging in the power cord AND record the time.
________ time _______
6.10.8 At the following signal injection test jacks, remove the voltage test sources:
6.10.8.1 QU 6.10.8.2 QL 6.10.9 At the following test point jacks, remove the precision voltmeter:
6.10.9.1 QU 6.10.9.2 QL 6.10.9.3 Q
6.10.9.4 T LAG SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 99 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.10.10 Close states block terminals 3, 6, 9, 12.
Independent Verification _______
6.10.11 Close the states block cover.
6.10.12 In Relay Rack RR-114, close the signal injection test panel cover AND check the following:
6.10.12.1 Annunciator (47035K) PROCESS PROTECT RACK 2 CHANNEL TEST is OFF.
6.10.12.2 SER (1680) PROCESS PROTECT RACK 2 CHANNEL TEST is NORMAL.
6.10.13 Using the time recorded in Step 6.10.4, verify TT-402A power has been restored for one hour.
6.10.14 Using the time recorded in Step 6.10.7, verify TT-402B power has been restored for one hour.
6.10.15 Have a Control Room Operator verify the following SER points are ENABLED:
6.10.15.1 RCS LOOP A CHANNEL 2 TAVG DEVIATION (974) _______
(Operator) 6.10.15.2 RCS LOOP A CHANNEL 2 DELTA TEMP DEVIATION (978) _______
(Operator)
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 100 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.10.16 In Relay Rack RR-114, place the following bistable output switches to NORMAL (down):
6.10.16.1 HI TAVG (402A) _______
6.10.16.2 LO/LO TAVG (402D) _______
6.10.16.3 F.W. VALVE OVERRIDE (402F) _______
6.10.16.4 OVER POWER TRIP (406A) _______
6.10.16.5 ROD STOP (directly below OVER POWER TRIP)
(406B) _______
6.10.16.6 OVER TEMP. TRIP (406C) _______
6.10.16.7 ROD STOP (directly below OVER TEMP. TRIP)
(406D) _______
6.10.16.8 HI PRESS. TRIP (430A) _______
6.10.16.9 LO PRESS. TRIP (430H) _______
6.10.16.10 UNBLOCK S.I.
(430F) _______
Independent Verification _______
6.10.16.11 S.I.
(430E) _______
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 101 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.10.17 IF reactor trip breakers are open AND auto SI is disabled, THEN N/A Steps 6.10.18 through 6.10.22.
6.10.18 Check the following annunciators are OFF:
6.10.18.1 OTT HIGH (47033C) _______
6.10.18.2 OPT HIGH (47033D) _______
6.10.18.3 PRESSURIZER PRESSURE 2385 (47041C) _______
6.10.18.4 PRZR PRESS SI CHANNEL ALERT (47041D) _______
6.10.18.5 OPT CHANNEL RNBACK/RDSTP ALERT (47041Q) _______
6.10.18.6 OTT CHANNEL RNBACK/RDSTP ALERT (47041R) _______
6.10.18.7 PRESSURIZER PRESSURE < 1900 (47042D) _______
6.10.18.8 RCS TAVG HIGH (47042H) _______
6.10.18.9 RCS LOOP A TAVG LOW LOW (47043H) _______
6.10.19 Check the following SER points are NORMAL:
6.10.19.1 REACTOR COOLANT SYSTEM LOOP A CHANNEL 2 TAVG HIGH (944) _______
6.10.19.2 OVERTEMPERATURE DELTA TEMP HIGH (1070) _______
6.10.19.3 PRESSURIZER PRESSURE < 1900 (1071) _______
6.10.19.4 OVERPOWER DELTA TEMP HIGH (1076) _______
6.10.19.5 PRESSURIZER PRESSURE 2385 (1080) _______
6.10.19.6 PRESSURIZER LOW PRESSURE SI CHANNEL ALERT (1173) _______
6.10.19.7 REACTOR COOLANT SYSTEM LOOP A TAVG LO-LO (1583) _______
6.10.19.8 OVERPOWER DELTA TEMP RUNBACK/RODSTOP ALERT (1685) _______
6.10.19.9 OVERTEMPERATURE DELTA TEMP RUNBACK/RODSTOP ALERT (1686) _______
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 102 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.10.20 Check the following status lamps are DIM:
6.10.20.1 LOOP A CHAN 2 OTT (44904-0101) _______
6.10.20.2 LOOP A CHAN 2 OPT (44904-0401) _______
6.10.20.3 PRESSURIZER 1900 PSIG (44907-0206) _______
6.10.20.4 PRESSURIZER 2385 PSIG (44907-0306) _______
6.10.20.5 LOOP A OTT (44907-0506) _______
6.10.20.6 LOOP A OPT (44907-0606) _______
6.10.20.7 PRESSURIZER 1815 PSIG (44908-0202) _______
6.10.20.8 LOOP A LOW TAVE (44908-0302) _______
6.10.20.9 LOOP A LOW-LOW TAVE (44908-0402) _______
6.10.21 Check status lamp (44908-0102) PRESSURIZER > 2000 PSIG is BRIGHT. _______
6.10.22 Check the following computer points are NOT TR:
6.10.22.1 RCLA OVERPOWER DT CHAN 2 (T0400D) _______
6.10.22.2 RCLA OVERTEMP DT CHAN 2 (T0403D) _______
6.10.22.3 PRESSURIZER HI P CH 2 (P0481D) _______
6.10.22.4 PRESSURIZER LOW P CH 2 (P0485D) _______
6.10.22.5 PRESSURIZER LO P CH 2 SI (P0490D) _______
6.10.22.6 SAFETY INJECTION CHAN 2 UNBLK (P0493D) _______
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 103 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.10.23 At Mechanical Control Console C, have a Control Room Operator place DELTA TEMPERATURE RX PROTECTION CHANNEL DEFEAT switch (ES-46374) to OFF.
OFF _______
(Operator)
Concurrent Verification _______
(Operator) 6.10.24 At Mechanical Control Console C, have a Control Room Operator place TAVE RX PROTECTION CHANNEL DEFEAT switch (ES-46375) to OFF.
OFF _______
(Operator)
Concurrent Verification _______
(Operator) 6.10.25 At Recorder 42301, select CAL STOP message.
6.10.26 Verify Recorder 42301 is displaying normal.
6.10.27 At Recorder 42553, select CAL STOP message.
6.10.28 Verify Recorder 42553 is displaying normal.
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 104 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.10.29 IF the PRZR PRESSURE CONTROL CHANNEL SELECTOR switch (ES-46324) is in the desired position, THEN N/A Step 6.10.30.
(Operator) 6.10.30 Notify the Control Room Operator, IF desired, operate Pressurizer Pressure controls in MANUAL using Operations procedure N-RC-36C, Pressurizer Pressure Control before transferring the PRZR PRESSURE CONTROL CHANNEL SELECTOR switch (Step 6.10.31).
(Operator) 6.10.31 At Mechanical Control Console C, have a Control Room Operator verify PRZR PRESSURE CONTROL CHANNEL SELECTOR switch (ES-46324) to the desired position AND circle that position.
4-3 / 2-3 / 2-1 _______
(Operator)
Concurrent Verification _______
(Operator) 6.10.32 Notify the Control Room Operator, IF desired, the controllers may be placed to AUTO.
(Operator)
Concurrent Verification _______
(Operator) 6.10.33 At Mechanical Control Console C, have a Control Room Operator verify PRZR PRESSURE RECORDER INPUT SELECTOR switch (ES-46325) to the desired position AND circle that position.
1 / 2 / 3 / 4 _______
(Operator)
Concurrent Verification _______
(Operator)
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 105 of 108 DATE PERFORMED __________
INITIALS CONTINUOUS USE Channel 2 (White) 6.10.34 At Mechanical Vertical Panel A, have a Control Room Operator verify TR-405 RX CLNT DELTA-TEMP RECORDER SELECTOR switch (ES-46551) to the desired position AND circle that position.
1 / 2 / 3 / 4 _______
(Operator)
Concurrent Verification _______
(Operator) 6.10.35 Notify the Control Room Operators of your completing this procedure.
(Operator)
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 106 of 108 CONTINUOUS USE Channel 2 (White) 7.0 Acceptance Criteria Reactor Condition (power level):
Channels Satisfactorily Tested Yes No Channel 2 (White)
M&TE ID DESCRIPTION CAL DUE Fluke 45 precision voltmeter Fluke 45 precision voltmeter Decade resistance box Decade resistance box Precision voltmeter Precision voltmeter Precision test resistor Plotter SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 107 of 108 CONTINUOUS USE Channel 2 (White) 7.1 This test is complete and acceptable once the following items have been completed and signed.
7.1.1 Section 6.0 has been completed.
7.1.2 Concurrent and Independent Verifications have been completed.
7.1.3 All problems encountered during the test have been properly resolved and signed, except as noted by a Condition Report (CR).
7.2 Were all As Found data entries within the acceptance range?
Yes
No Initials: _____
N/A 7.3 Are all Final data entries within the acceptance range?
Yes
No Initials: _____
N/A 7.4 Were any problems or discrepancies noted while performing this procedure?
Yes CR No. _______________
No 8.0 Review 8.1 Performed by:
_______________________ Initials: _____ Date: __________
(Print / Sign)
_______________________ Initials: _____ Date: __________
(Print / Sign)
Group Supervisor: _______________________
Date: __________
(Print / Sign)
SUPERSEDED
DOMINION ENERGY KEWAUNEE, INC No.
SP-47-011B Rev.
17 Kewaunee Power Station Title Reactor Coolant Temperature and Pressurizer Pressure Instrument Channel 2 (White) Calibration Surveillance Procedure Date APR 22 2008 Page 108 of 108 CONTINUOUS USE Channel 2 (White) 9.0 Records 9.1 The following QA records and non-QA records are identified in this directive/procedure and are listed on the KPS Records Retention Schedule. These records shall be maintained according to the KPS Records Management Program.
9.1.1 QA Records Completed procedure 9.1.2 Non-QA Records None SUPERSEDED