ML102020366

From kanterella
Jump to navigation Jump to search
Assignment Report 00927310
ML102020366
Person / Time
Site: Oyster Creek
Issue date: 06/03/2009
From:
AmerGen Energy Co
To:
Office of Information Services
References
FOIA/PA-2009-0214 AR 00927310
Download: ML102020366 (2)


Text

AR - Assignment Report Page 1 of 2 x

,:Back,

.Print New Search Home o ac AR 00927310 Report Aff Fac:

Oyster Creek AR Type:

CR Status:

APPROVED' Aff Unit:

NA.

Owed To:

A5332CAP Due Date:

07/03/2009 Aff System:

Event Date:

06/01/2009 CR 4/D Disc Date:

06/01/2009 Level/Class:

How H02 Orig Date:

06/03/2009 Discovered:

WRIPIMS AR:

Component #:

Action Request Details

Subject:

FALSE POSITIVE TRITIUM FROM ANALYSIS OF WELL WATER

==

Description:==

Originator: JAMES J VOUGLITOIS Supv Contacted: J. Kandasamy Condition

Description:

As part of the ongoing investigation of the tritiated water that leaked from underground pipes, monitoring well MW-1I-1A was sampled on 05/27/09.

The Chemistry Department filtered and analyzed this water sample in accordance with CY-OC-130-530 "Tritium Analysis Liquid Samples". The results of the analysis showed 83,000 pCi/L tritium. This result was inconsistent with the facts that all prior samples from this well showed no detectable tritium, and that the well is located in an area not believed to be impacted by the pipe leaks. Suspecting a false positive result due to interferences caused by sediment or micro-organisms in the sample, the sample was distilled andre-analyzed in accordance with CY-OC-130-530. The result of the re-analysis was less than the lower limit of detection.

Immediate actions taken:

Discussed the anomaloius result with the Chemistry Supervisor and requested the distallation/re-analysis.

Recommended Actions:

Close to trend.

What activities, processes, or procedures were involved?

Analysis of well water samples in accordance with CY-OC-130-530 "Tritium Analysis Liquid Samples" Why did the condition happen?

Interferences caused by sediment or micro-organisms in the sample.

What are the consequences?

None - The distallation and re-analysis in accordance with the procedure eliminated the interferences.

Were any procedural requirements impacted?

No - The analysis and re-analysis were performed in accordance with the procedure ( CY-OC-130-530 "Tritium Analysis Liquid Samplesý').

Were there any adverse physical conditions?

NA httD ://eamienco.ceco.com/caD/se'rvlet/ReDortARServlet 6/3/200.9

,-AR - Assignment Report Page 2 of 2 List of knowledgeable individuals:

J. Kandasamy, L. Birkmire, J. Vouglitois Repeat or similar condition?

No '- not as part of this investigation.

Operable Basis:

N/A Reportable Basis:

N/A Reviewed by: HERBERT G TRITT II 06/03/2009 12:05:09 CDT Reviewer Comments:

none Dynamic AR Attributes KEYWORD:

ENV Assignments Assign #:

01 Assigned To:

Status:

AWAIT/C Aff Fac:

Oyster Creek Prim Grp:

ACAPALL Due Date:

06/08/200.9 Assign Type:

TRKG Sec Grp:

Orig Due Date:

pp/pp/pppp Priority:

Schedule Ref:

Unit Condition:

Subject/Description:

FALSE POSITIVE TRITIUM FROM ANALYSIS OF WELL WATER http://eamgenco.ceco.com/cap/servlet/ReportARServlet 6/3/2009