UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 July 22, 2010 Mr. Adam C. Heflin Senior Vice President and Chief Nuclear Officer Union Electric Company P.O. Box 620 Fulton, MO 65251
SUBJECT:
CALLAWAY PLANT, UNIT 1 - CORRECTION OF TECHNICAL SPECIFICATION PAGES 3.7-45 AND 3.7-46, ISSUED WITH AMENDMENT NO. 197, WHICH REVISED TECHNICAL SPECIFICATIONS 3.3.2 AND 3.7.2, AND ADDED A NEW TECHNICAL SPECIFICATION 3.7.19 (TAC NO. ME1324)
Dear Mr. Heflin:
By letter dated May 28, 2010 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML101121025), the U.S. Nuclear Regulatory Commission (NRC) issued the Amendment No. 197 to Facility Operating License No. NPF-30, for Callaway Plant, Unit 1. The amendment consisted of changes to the Technical Specifications (TSs) in response to your application dated May 4,2009 (ADAMS Accession No. ML091310167) (ULNRC-05566).
Amendment No. 197 revised TS 3.3.2, "Engineered Safety Feature Actuation System Instrumentation," and TS 3.7.2, "Main Steam Isolation Valves (MSIVs), Main Steam Isolation Valve Bypass Valves (MSIVBVs), and Main Steam Low Point Drain Isolation Valves (MSLPDIVs)," and added new TS 3.7.19, "Secondary System Isolation Valves (SSIVs)."
By electronic mail dated June 8,2010 (ADAMS Accession No. ML101940116), Mr. Thomas Elwood of your staff informed the NRC that a typographical error had been identified on TS pages 3.7-45 and 3.7-46 forwarded in Amendment No. 197. The page break of page 3.7-45 was incorrectly located immediately after REQUIRED ACTION A.2, instead of after "(continued)"
which had moved to the following page 3.7-46. The licensee stated that it had provided the correct pages 3.7-45 and 3.7-46 to NRC, and requested that the correct pages replace the erroneous pages.
The NRC staff reviewed the licensee's request and determined that the error was caused in the licensee-supplied revised pages for Amendment No. 197. The erroneous pages were sent by your staff by electronic mail on May 22, 2010, to Ms. Janet Burkhardt of the NRC staff, and were incorporated in the Amendment No. 197 as received by the NRC staff.
The NRC staff agrees that the pages should be corrected as requested by the licensee.
Accordingly, TS pages 3.7-45 and 3.7-46 have been corrected, and are enclosed for replacement in the Amendment No. 197.
A. Heflin
- 2 If you have any questions, please contact me at (301) 415-1476 or bye-mail at mohan.thadani@nrc.gov.
Sincerely, Mohan C. Thadani, Senior Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-483
Enclosure:
As stated cc w/encl: Distribution via Listserv
ENCLOSURE CALLAWAY PLANT, UNIT 1 DOCKET NO.
REPLACEMENT TECHNICAL SPECIFICATION PAGES 3.7-45 50-483 AND 3.7-46 FOR AMENDMENT NO. 197
SSIVs 3.7.19 3.7 PLANT SYSTEMS 3.7.19 Secondary System Isolation Valves (SSIVs)
LCO 3.7.19 The SSIVs shall be OPERABLE.
NOTE --------------------------------------------
Locked closed manual SSIVs may be opened under administrative controls.
APPLICABILITY:
MODES 1, 2, and 3 except for each secondary system flow path when:
- a.
At least one of the two associated SSIVs is closed and de-activated; or
- b.
At least one of the two associated SSIVs is closed and isolated by a closed manual valve; or
- c.
The SSIV flow path is isolated by two closed manual valves, or two closed de-activated automatic valves, or a combination of a closed manual valve and a closed de-activated automatic valve.
ACTIONS
NOTE ----------------------------------------------------------
Separate Condition entry is allowed for each secondary system flow path.
CONDITION REQUIRED ACTION COMPLETION TIME A.
One or more SSIVs inoperable.
NOTE ------------------
Closed or isolated automatic SSIVs may be opened or unisolated under administrative controls.
A.1 AND.
Close or isolate SSIV.
A.2 Verify SSIV is closed or isolated.
7 days Once per 7 days (continued)
CALLAWAY PLANT 3.7-45 Amendment No. 197
3.7.19 SSIVs ACTIONS (continued)
CONDITION B.
Required Action and Associated Completion Time not met.
B.1 AND B.2 REQUIRED ACTION Be in MODE 3.
Be in MODE 4.
COMPLETION TIME 6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> 12 hours SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.19.1 Verify the isolation time of each automatic SSIV is within limits.
In accordance with the Inservice Testing Program SR 3.7.19.2 Verify each automatic SSIV in the flow path actuates to the isolation position on an actual or simulated actuation signal.
18 months CALLAWAY PLANT 3.7-46 Amendment No. 197
A. Heflin
- 2 If you have any questions, please contact me at (301) 415-1476 or bye-mail at mohan.thadani@nrc.gov.
Sincerely, Ira!
Mohan C. Thadani, Senior Project Manager Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-483
Enclosure:
As stated cc w/encl: Distribution via Listserv DISTRIBUTION:
PUBLIC LPLIV Reading RidsAcrsAcnw_MailCTR Resource RidsNrrDirsltsb Resource RidsNrrDorlLpl4 Resource RidsNrrDssSbpb Resource RidsNrrLAJBurkhardt Resource RidsNrrPMCallaway Resource RidsOgcRp Resource RidsRgn4MailCenter Resource MHarnm, NRR/DIRS/ITSB SJones, NRR/DSS/SBPB ADAMS Accession No. ML101950210 OFFICE NRR/LPL4/PM NRR/LPL4/LA NRR/LPL4/BC NRR/LPL4/PM NAME MThadani JBurkhardt MMarkley (MThadani for)
MThadani (NKalyanam for)
DATE 7/22/10 7/21/10 7/22/10 7/22/10 OFFICIAL RECORD COpy