FENOC Follow-Up on Davis-Besse RPV Head Penetration Nozzle 50.55a Request Status Update Telecon
ML101460479
Person / Time
Site: Davis Besse Cleveland Electric icon.png
Issue date: 05/26/2010
From:
FirstEnergy Corp
To: Michael Mahoney
Plant Licensing Branch III
mahoney, m NRR/DORL/LPLIII-2 415-3867
References
Download: ML101460479 (1)


Text

From: talentz@firstenergycorp.com Sent: Wednesday, May 26, 2010 10:19 AM To:

Mahoney, Michael Cc:

phlashley@firstenergycorp.com; kmnesser@firstenergycorp.com; kwbyrd@firstenergycorp.com; apwise@firstenergycorp.com; awbless@firstenergycorp.com; gmwolf@firstenergycorp.com

Subject:

FENOC Follow-up on Davis-Besse RPV Head Penetration Nozzle 50.55a Request Status Update Telecon Mike:

In response to the telecon conducted on May 24, 2010, FENOC provides the following requested information/clarification:

1. Per our discussion this morning, the NRC has received the proprietary calculations that were submitted by FENOC on May 17, 2010 and they have been forwarded to the appropriate technical reviewers. No further action is required by FENOC.
2. As a result of a question from the NRC Special Inspection Team it was discovered that the post-weld PT examinations for ten nozzles did not have sufficient coverage in bands of the examination area due to the field of view on the camera vs the spacer size used. This post weld PT examination overlap issue affected nozzles. 10, 24, 28, 43, 51, 55, 58, 59, 61 and 67.

This is documented in the site corrective action program under FENOC CR 10-77201 (Areva CR 2010-3544). As a result, the post weld PTs for these nozzles are being reperformed. For nozzles 51, 55, 58, 59, 61 and 67, since abrasive water jet machining remediation has already been completed, the PT will now be performed after water jet remediation. This is contrary to the process overview provided in our April 1, 2010, 10 CFR 50.55a request. Specifically, on page 4 of 20 of the Enclosure, FENOC provided an overview of the basic steps of the repair process. Step 6 and 7 will now be reversed for these six nozzles.

As discussed on the telecon yesterday and, in part, in our April 16, 2010 response to RAI Question 2(4), the order of these two steps can be interchanged, as the material removed by the water jetting is minimal (approximately 0.030 inches) and the abrasive water jet machining remediation will not interfere with the subsequent surface examination (i.e., the abrasive water jet machining remediation is not considered a peening process).

3. As provided in our May 17, 2010 response to RAI Question 3(2), the examination area for the preservice examination following repair and for future inservice inspections shall include the wetted surface of the new weld from the toe of the weld up through 0.5 inches above the rolled

region of the nozzle remnant. In accordance with Figure 3 of the Enclosure of the April 1, 2010, 10 CFR 50.55a request, during the post-weld PT examination following repairs, the examination includes the area 1/2 inch below the toe of the weld. This PT will also serve as the preservice examination.

As noted in the 50.55a request, FENOC plans to use a surface examination method for future inservice inspections. If PT is used, the examination will be in accordance with Code Case N-729-1 and the 50.55a request and may include some portion of the area below the toe of the weld to ensure adequate coverage of the weld. If other surface or volumetric examination techniques (e.g. eddy current or UT) are developed and qualified per Code Case N-729-1, the qualified examination area would include, as a minimum the wetted surface of the new weld from the toe of the weld up through 0.5 inches above the rolled region of the nozzle remnant.

4. In accordance with our current plan, NDE examination of nozzle 4 (PT/UT) is in progress and results are expected to be available on Thursday, May 27, 2010.

They will be provided to you electronically when available.

Subsequent to the May 24, 2010 telecon, the NRC provided the following additional question via email on May 25, 2010 (question highlighted in bold):

By letters dated April 1, 2010 and May 17, 2010, the licensee submitted the half nozzle repair relief request for the control rod drive mechanism (CRDM) nozzles at Davis Besse. In response to RAI Question number 2 in to the May 17, 2010, submittal, the licensee stated that Code Case N-416-3 will be used to satisfy pressure testing requirements subsequent to the CRDM nozzle repair. In the teleconference dated May 24, 2010, the licensee indicated that it will perform a visual (VT-2) examination from outside the service structure of the reactor pressure vessel without any direct view of the surface of the head in the areas that were repaired during the system leakage test.

In general, the NRC accepts this type of indirect visual (VT-2) examination. However, it may not be appropriate for Davis-Besse CRDM nozzle repairs based on the following:

1) A larger number of repaired CRDM nozzles increases possibility for fabrication defects that may be missed by nondestructive examination.
2) Several unsuccessful repairs on CRDM nozzle 4 create the possibility for unforeseen fabrication defects.
3) Inability of a visual (VT-2) examination from the outside service structure to detect small leakage from a through-wall

fabrication defect in a repaired nozzle.

For these reasons, the staff requests a direct viewing of the bare metal head surface through one or more access hole penetrations during the system leakage test to provide an additional defense in-depth and increase confidence in these nozzle repairs.

Alternatively, the licensee needs to justify why the proposed indirect visual (VT-2) examination is acceptable.

5. As noted in the 50.55a request, the CRDM nozzle repair weld is a partial penetration weld.

ASME Code NB-5245 requires a progressive surface examination of partial penetration welds.

In lieu of the progressive surface examination, a surface examination and an ultrasonic examination, qualified to detect flaws in the new weld and base material is performed on the partial penetration weld as described in the 50.55a request, Figure 3.

This UT examination, exceeds construction code requirements and along with the liquid penetrant examination of the weld area provides a high degree of confidence in the integrity of the repair weld.

Pressure testing requirements will be met by the completion of a VT-2 examination that will be conducted in accordance with the requirements of IWA-5000 and Code Case N-416-3 which is endorsed in NRC Regulatory Guide 1.147 Revision 15 with no conditions noted. IWA-5000 permits a VT-2 visual examination with insulation installed. As specified in IWA-5242, the VT-2 examination will be conducted at the lowest elevation where leakage may be detectable. Examination of the surrounding area such as floor areas, equipment surfaces or underneath components is required.

A remote VT-2 examination will be conducted by examining the refueling canal floor in the area of the reactor vessel flange. A direct VT-2 examination of the reactor vessel insulation joints from under the reactor vessel will also be performed. Together, the NDE and pressure test visual examination will provide a high level of confidence in the integrity of the CRDM repairs.

The CRDM penetrations are located within the service structure below the reactor vessel heads insulation package. Access to this area is available through inspection ports, however, during the system leakage test, the Reactor Coolant System is at normal operating temperature and pressure (approximately 532 degrees Fahrenheit and 2150 psig) with all insulation in place as permitted by IWA-5000. This insulation covers the inspection ports.

Opening the inspection ports would require removal of the insulation and the hot inspection ports. Air emitted from the

ports could approach 500 degrees Fahrenheit. Inspection would be difficult and access would require personnel to be in close proximity to the hot surfaces creating an industrial safety hazard.

The benefit of this direct visual examination is considered to be limited given the additional level of NDE and pressure test visual examination noted above.

The information contained in this message is intended only for the personal and confidential use of the recipient(s) named above. If the reader of this message is not the intended recipient or an agent responsible for delivering it to the intended recipient, you are hereby notified that you have received this document in error and that any review, dissemination, distribution, or copying of this message is strictly prohibited. If you have received this communication in error, please notify us immediately, and delete the original message.

E-mail Properties Mail Envelope Properties (OF5C7D5655.DBC1F7F6-ON8525772E.006456D7-8525772F.004EAA9F)

Subject:

FENOC Follow-up on Davis-Besse RPV Head Penetration Nozzle 50.55a Request Status Update Telecon Sent Date:

5/26/2010 10:19:21 AM Received Date:

5/26/2010 10:19:21 AM From:

talentz@firstenergycorp.com Created By:

talentz@firstenergycorp.com Recipients:

Michael.Mahoney@nrc.gov (Mahoney, Michael)

Tracking Status: None phlashley@firstenergycorp.com (phlashley@firstenergycorp.com)

Tracking Status: None kmnesser@firstenergycorp.com (kmnesser@firstenergycorp.com)

Tracking Status: None kwbyrd@firstenergycorp.com (kwbyrd@firstenergycorp.com)

Tracking Status: None apwise@firstenergycorp.com (apwise@firstenergycorp.com)

Tracking Status: None awbless@firstenergycorp.com (awbless@firstenergycorp.com)

Tracking Status: None gmwolf@firstenergycorp.com (gmwolf@firstenergycorp.com)

Tracking Status: None Post Office:

FirstEnergyCorp.com Files Size Date & Time MESSAGE 20433 5/26/2010 Options Expiration Date:

Priority:

olImportanceNormal ReplyRequested:

False Return Notification:

False Sensitivity:

olNormal Recipients received: