L-2010-078, Attachment 5, St. Lucie Unit 1, Extended Power Uprate Licensing Report, Appendix F, Caldon Ultrasonics Engineering Reports, No. 733, Rev 3, and No. 740, Rev 0

From kanterella
(Redirected from ML101160202)
Jump to navigation Jump to search
Attachment 5, St. Lucie Unit 1, Extended Power Uprate Licensing Report, Appendix F, Caldon Ultrasonics Engineering Reports, No. 733, Rev 3, and No. 740, Rev 0
ML101160202
Person / Time
Site: Saint Lucie NextEra Energy icon.png
Issue date: 04/16/2010
From:
Florida Power & Light Co
To:
Office of Nuclear Reactor Regulation
Shared Package
ML101160214 List:
References
L-2010-078
Download: ML101160202 (2)


Text

St. Lucie Unit 1 L-2010-078 Docket No. 50-335 Attachment 5 _____________________________________________________________________________ St. Lucie Unit 1 EPU Licensing Report Appendix F-1 St. Lucie Unit 1 Extended Power Uprate Licensing Report Attachment 5 Appendix F Caldon Ultrasonics Engineering Reports Engineering Report No. 733, Rev. 3 Meter Factor Calculation and Accuracy Assessment for St. Lucie Unit 1 Engineering Report No. 740, Rev. 0 Bounding Uncertainty Analysis for Thermal Power Determination at St. Lucie Units 1 & 2 Using the LEFM Checkplus System Caldon Ultrasonics Engineering Reports St. Lucie Unit 1 L-2010-078 Docket No. 50-335 Attachment 5 _____________________________________________________________________________ St. Lucie Unit 1 EPU Licensing Report Appendix F-2 Caldon Ultrasonics Engineering Reports Proprietary Information Withhold from Public Disclosure Pursuant to 10 CFR 2.390