AR - Assignment Report Go Back Print New Search Home AR 00914347 Report Aft Fac:

Oyster Creek AR Type:

CR Status:

COMPLETE Aft Unit:

NA Owed To:

A5332CAP Due Date:

05/31/2009 Aff System:

Event Date:

04/29/2009 CR Level/Class: 4/D Disc Date:

04/29/2009 How H02 Orig Date:

05/01/2009 Discovered:

WR/PIMS AR:

Component #:

Action Request Details

Subject:

LESSON LEARNED TRITIUM ANALYSIS IN THE HOT LAB

==

Description:==

Originator: LEANNE K BIRKMIRE Supv Contacted: Jhansi Kandasamy Condition

Description:

On 04/29/09 tritium samples were taken for support of the tritium ACMP..

One of these sample had known tritium activity. When the samples were distilled the sample with known tritium activity was distilled first after a blank for cleanliness verification. After the sample with known tritium activity was run it contaminated the sample that was run after it.

Immediate actions taken:

The samples were distilled again with a blank and then the samples were run. The samples were distilled from the least amount of tritium based on previous results to the highest amount of tritium based on previous results and then a blank was run to verify cleanliness of the distillation after all samples were complete.

Recommended Actions:

Samples were re-run and results were consistent with what was expected and previous results. Technician involved was briefed on the logistic of sequencing analysis.

Operable Basis:

N/A Reportable Basis:

N/A Reviewed by: HERBERT G TRITT II 05/02/2009 02:22:38 CDT Reviewer Comments:

none SOC Reviewed by: JAMES J VOUGLITOIS 05/04/2009 11:59:32 CDT SOC Comments:

Follow up Chemistry 05/04/09 ]JV: Close to actions taken.

Reviewed by: PHILIP E OLIVIERI 05/05/2009 08:14:12 CDT Reviewer Comments:

Coaching was provided to technicians and participants in tritium analysis from other sites that sample prep distillations should be performed starting with sampels with lowest activity, absed on previous results, to http://eamgenco.ceco.com/cap/servlet/ReportARServlet 6/23/2009

AR-Assi Page 2 of 2 sampels with greatest activity to avoid cross-contamination.

Dynamic AR Attributes CREW RESET1i:

Chemistry KEYWORD:

LL Trend Codes TC1 TC2 TC3 Proc Org Rank ECY103 CY90 CH P

Assignments Assign #:

01 Assigned To:

Status:

COMPLETE Aft Fac:

Oyster Creek Prim Grp:

ACAPALL Due Date:

05/06/2009 Assign Type:

TRKG Sec Grp:

Orig Due Date:

Priority:

Schedule Ref:

Unit Condition:

Subject/Description:

LESSON LEARNED TRITIUM ANALYSIS IN THE HOT LAB i