Log Sheet
ML100740167
Person / Time
Site: Oyster Creek
Issue date: 04/25/2009
From:
- No Known Affiliation
To:
Office of Information Services
References
FOIA/PA-2009-0214
Download: ML100740167 (1)


Text

logs gage 11 ot 14 Swing Shift 4/25/2009 12:24:13 AM Log approved by Moore, Dennis M Mid Shift 4/25/2009 Pre-Shift Briefing discussion included: Braidwood scram 12:35:00 AM while performing 1/2 scram testing due to spike in other RPS system, and work management fundamental for reviewing the schedule for conflicts.

Mid Shift 4/25/2009 Commenced Surveillance Test 666.3.009, AOG 12:40:31 AM RECOMBINER DISCHARGE HYDROGEN AND TEMERATURE MONITOR CALIBRATION for the A recombiner. R2136801 Log Date Entry Use 4/2S/2009 Completed Surveillance Test 666.3.009, AOG RECOMBINER DISCHARGEBa 4/25/2009 HYDROGEN AND TEMERATURE MONITOR CALIBRATION for the A recombiner.

Ba 6:29:53 AM R2136801, sat.Ma Mid Shift 4/25/2009 Completed Core Daily Checks per procedure 202.1 for the 12:45:27 AM midnight shift. sat.

Mid Shift 4/25/2009 Commenced Surveillance Test 677.4.001, CANAL WATER 12:50:00 AM TEMPERATURE MONITORING SYSTEM-CHANNEL AND ALARM CHECK.

Log Date Entry User 4/25/2009 Completed Surveillance Test 677.4.001, CANAL WATER TEMPERATURE Bara 1:03:43 AM MONITORING SYSTEM-CHANNEL AND ALARM CHEC:K.sat.

Mari Mid Shift 4/25/2009 Singer, Kris Assumed EO Intake Position. NOTE: Performed 12:52:43 AM by: Singer, Kris Mid Shift 4/25/2009 Made up to the containment via V-23-17 and V-23-18 in 12:53:00 AM accordance with procedure 312.11. - Initial pressure 1.08 PSIG - Finial pressure 1.13 PSIG Mid Shift 4/25/2009 Core Spray System 1 is filled and vented in accordance 2:08:40 AM with procedure 308.

Mid Shift 4/25/2009 Received a report from RP that there is a leak from the 2:12:00 AM west wall of the excavation hole of approximately 1 GPM of warm water between the CST and the Condensate transfer house. Preliminary results are that the water is contaminated from a frisk of a glove immersed in the leak.

The field supervisor and intake operator were dispatched.

Chemistry will be sampling the water. Initial WD level is 30.8 ft., and the CST is 33.5 ft.

Log Date Entry User 4/25/2009 Chemistry Technician informed the Control Room that the sample of water Johnston found in the excavation exhibited a gamma source of Xe-135 at a 3:55:00 AM Steven P concentration of 7.05 E-7 microcuries per milliliter.

Completed conference call with duty station manager, director of training, 4/25/2009 chemistry manager. plant manager, and SVP regarding water flow into Johnston 3:40:02 AM excavation on the north west side of the condensate transfer house. OCC Steven P member have been paged to restaff.

4/25/2009 Completed phone calls to site radiation protection manager, and site reg.

Johnston 4:30:26 AM assurance manager regarding water flow into excavation on the north west Steven P side of the condensate transfer house.