ML100470359

From kanterella
Jump to navigation Jump to search

Relief Request 09-GO-001, Regarding Alternatives from Pressure Test Requirements for Buried Piping
ML100470359
Person / Time
Site: McGuire, Mcguire  Duke Energy icon.png
Issue date: 02/18/2010
From: Kulesa G
Plant Licensing Branch II
To: Repko R
Duke Energy Carolinas
Stang J, NRR/DORL, 415-1345
References
TAC ME0958, TAC ME0959
Download: ML100470359 (7)


Text

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 February 18, 2010 Mr. Regis T. Repko Vice President McGuire Nuclear Station Duke Energy Carolinas, LLC 12700 Hagers Ferry Road Huntersville, NC 28078

SUBJECT:

MCGUIRE NUCLEAR STATION, UNITS 1 AND 2, RELIEF REQUEST 09-GO-001, REGARDING ALTERNATIVES FROM PRESSURE TEST REQUIREMENTS FOR BURIED PIPING (TAC NOS. ME0958 AND ME0959)

Dear Mr. Repko:

By letter dated February 24,2009, as supplemented by letter dated August 27,2009, Duke Energy Carolinas, LLC (Duke, the licensee), submitted relief request (RR) 09-GO-001 for McGuire Nuclear Station, Units 1 and 2 (McGuire 1 and 2), related to the Inservice Inspection (lSI)

Program for the third 10-year interval pertaining to system pressure tests. The licensee requested approval of a proposed alternative to the American Society of Mechanical Engineers (ASME), Boiler and Pressure Vessel Code (Code) from performing required pressure tests of the buried components of the nuclear service water system. The Code requires measuring the rate of pressure loss or change in flow between the ends of the buried components. The licensee proposed an alternative test that will confirm that flow of the nuclear service water system is not impaired during normal plant operation. The Code of Record for McGuire 1 and 2 is the 1998 Edition through the 2000 Addenda of the ASME Code.

Based on the information provided by the licensee, the Nuclear Regulatory Commission (NRC) staff has determined that the licensee's compliance to the Code of record would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety. Therefore, pursuant to Title 10 of the Code ofFederal Regulations, Part 50, Section 50.55a(a)(3)(ii), the NRC authorizes the proposed alternative in RR 09-GO-001 for the third 10-year lSI interval for McGuire 1 and 2, which is scheduled to end on November 30, 2011, for McGuire 1 and February 18, 2014, for McGuire 2. Enclosed is the NRC's Safety Evaluation.

R. Repko

- 2 If you have any questions concerning this action, please contact John Stang of my staff at 301-415-1345 Sincerely, Gloria Kulesa, Chief Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-369 and 50-370

Enclosure:

Safety Evaluation cc w/encl: Distribution via Listserv

UNITED STATES NUCLEAR REGULATORY COMMISSION WASHINGTON, D.C. 20555-0001 SAFETY EVALUATION BY THE OFFICE OF NUCLEAR REACTOR REGULATION REQUEST FOR APPROVAL OF RELIEF 09-GO-001 REGARDING ALTERNATIVES FROM PRESSURE TEST REQUIREMENTS FOR BURIED PIPING MCGUIRE NUCLEAR STATION, UNITS 1 AND 2 DUKE ENERGY CAROLINAS, LLC DOCKET NOS. 50-369 AND 50-370

1.0 INTRODUCTION

By letter dated February 24, 2009, Agencywide Documents Access and Management System (ADAMS) Accession No. ML090890782), as supplemented by letters dated August 27,2009 (ADAMS Accession No. ML092520032), Duke Energy Carolinas, LLC (the licensee), submitted relief request (RR) 09-GO-001 for the McGuire Nuclear Station, Units 1 and 2 (McGuire 1 and 2) related to the Inservice Inspection (lSI) Program for the third 1O-year interval for McGuire 1 and 2.

The licensee requested approval of a proposed alternative to the American Society of Mechanical Engineers (ASME), Boiler and Pressure Vessel Code (Code) for required pressure test of the buried components of the nuclear service water system. The Code requires measuring the rate of pressure loss or change in flow between the ends of the buried components. The licensee proposed an alternative test that will confirm that flow is not impaired during normal operation.

The integrity of the buried piping will be ensured during unimpaired flow testing for each train of the nuclear service water system by balancing the flow from the output of the nuclear service water pumps against the total measured flow through various nuclear safety-related loads. All of the individual component flows are recorded and verified against the owner-established flow acceptance criteria. In addition to the unimpaired flow test, the licensee will perform a visual examination of the ground surface areas above components buried to detect evidence of through-wall leakage in buried components. The Nuclear Regulatory Commission (NRC) staff has reviewed the licensee's proposed alternative pursuant to Title 10 to Code of Federal Regulations (10 CFR), Part 50, Section 50.55a(a)(3)(ii) on the basis that compliance to the Code requirement would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.

2.0 REGULATORY REQUIREMENTS Section 50.55a(g) requires that lSI of ASME Code Class 1, 2, and 3 components be performed in accordance with Section XI of the ASME Code and applicable addenda, except where specific written relief has been granted by the Commission pursuant to 10 CFR 50.55a(g)(6)(i). According Enclosure

- 2 to 10 CFR 50.55a(a)(3), alternatives to the requirements of paragraph 50.55a(g) may be used, when authorized by the NRC, if an applicant demonstrates that the proposed alternatives would provide an acceptable level of quality and safety or if the specified requirement would result in hardship or unusual difficulty without a compensating increase in the level of quality and safety.

Pursuant to 10 CFR 50.55a(g)(4), ASME Code Class 1,2, and 3 components (including supports) shall meet the requirements, except the design and access provisions and the preservice examination requirements, set forth in ASME Code,Section XI, Rules for lSI of Nuclear Power Plant Components, to the extent practical within the limitations of design, geometry, and materials of construction of the components. The regulations require that lSI of components and system pressure tests conducted during the first 1O-year interval and subsequent intervals comply with the requirements in the latest edition and addenda of Section XI of the ASME Code incorporated by reference in 10 CFR 50.55a(b) twelve months prior to the start of the 120-month interval, subject to the limitations and modifications listed therein. The lSI Code of Record for the third 1O-year inspection interval at McGuire 1 and 2 is the 1998 Edition, through the 2000 Addenda of the ASME Code,Section XI.

3.0 TECHNICAL EVALUATION

System/Component(s) for Which Relief is Requested ASME Code Class 3 nuclear service water system buried piping at McGuire 1 and 2.

ASME Code Requirements As applicable to the McGuire 1 and 2, the 1998 Edition through the 2000 Addenda of the ASME Code,Section XI, Table IWO-2500-1, Examination Category O-B, Item Number 02.10 requires a system pressure test and a VT-2 visual examination. Subsection IWA-5244(b) requires buried components that are isolable by means of valves be tested to determine the rate of pressure loss in the buried components. Alternatively, the test may determine the change in flow between the ends of the buried components. The system pressure test for nonisolable buried components shall consist of a test to confirm that flow during operation is not impaired.

Licensee's Request for Relief Approval of a proposed alternative is requested from performing the system pressure test for buried portions of Class 3 piping that are isolable by means of valves by determining the rate of pressure loss or the change in flow between the ends of buried piping.

Licensee's Basis for Requesting Relief The buried piping segments of the Class 3 nuclear service water piping at McGuire 1 and 2 are bounded by butterfly valves that are not designed or expected to provide an adequate leak tight boundary that is necessary for an accurate pressure decay test. To perform an accurate rate of pressure loss test, extensive maintenance or system modifications would be required. Also, the buried piping is not instrumented to measure change of flow at the ends. The licensee has proposed an alternative to perform the unimpaired flow test. Neither the change in flow test

[IWA-5244(b)(1)] nor the unimpaired flow test [IWA-5244(b)(2)] is sufficiently sensitive to detect

- 3 small through-wall leakage in these buried components, due to relatively high system flow rates and accuracy of flow measurement instrumentation. As such, there is no appreciable difference between the level of quality and safety achieved by performing either of these tests.

Visual examinations of ground surface areas are capable of detecting potentially small through-wall leakage in the buried component. These visual examinations and unimpaired flow tests will provide reasonable assurance of the structural and leak-tight integrity of the buried components.

For McGuire 1 and 2, the unimpaired flow tests for the buried piping identified in the relief request are conducted in accordance with "RN [Nuclear Service Water] Flow Balance" for each train of nuclear service water system. In accordance with Generic Letter (GL) 89-13 "Service Water System Problems Affecting Safety-Related Equipment," the flow balancing is performed as part of licensee's test program at the design basis flow rates to ensure that all components are not fouled or clogged and that they will be able to receive their design basis flow rates simultaneously. Flow rates measured during flow balance testing are verified to meet the licensee's flow acceptance criteria for each cooled components. If the measured nuclear service water system flow is less than the specified acceptance criteria, the nuclear service water train is declared inoperable and the appropriate Limiting Condition for Operating of the Technical Specifications is entered into. In addition, the condition is entered into the licensee's corrective action program for resolution.

Licensee's Proposed Alternative The licensee proposes to use as an alternative to the requirements of IWA-5244(a) or IWA-5244(b), a verification that flow during operation is not impaired in non-isolable buried piping.

For each segment of the buried pipe, periodic flow testing will be performed in accordance with flow balance test procedure for each train. These surveillance procedures require flow to be measured, recorded and compared to established acceptance criteria to provide assurance that flow is not impaired during operation. In addition to the unimpaired flow test, the licensee will perform a visual examination of the ground surface areas above components buried to detect evidence of through-wall leakage in buried components.

4.0 NRC STAFF'S EVALUATION The Code of Record for McGuire 1 and 2 requires a system pressure test for the buried portion of the nuclear service water piping and the condenser circulating water that will determine either a rate of pressure loss or a change in flow at the ends of the buried piping. The buried piping at McGuire 1 and 2 uses butterfly valves at the ends which were not designed for pressure isolation and therefore, are unsuitable to determine meaningful rate of pressure loss. One end of the buried piping is not instrumented for flow measurement which does not permit measurement of change in flow at the ends of the buried pipe. Therefore, the ASME Code-required test cannot be performed. In order to comply with the ASME Code requirement, extensive maintenance or system modification would be required or additional instrumentation need to be installed in the buried piping which would result in hardship to the licensee. The ASME Code, however, allows for nonisolable testing for buried components to confirm that flow during operation is not impaired.

The NRC staff agrees with the licensee's approach that unimpaired flow in the buried piping can be qualitatively assessed during the flow balance test routinely performed in accordance with GL 89-13. The procedure for the flow balance testing will confirm that the nuclear service water

- 4 GL 89-13. The procedure for the flow balance testing will confirm that the nuclear service water system of each unit is capable of supplying the design basis cooling water to various nuclear safety-related loads. During this test alignment, all of the individual component flows are recorded, including the total system flow and the opposite unit system flow. The recorded test flows are verified against the licensee's established flow acceptance criteria. The NRC staff finds that the licensee's proposed test performed in accordance with the GL 89-13 program will ensure unimpaired flow in the buried piping given that the specified flow from each of the pumps is available, assuming no major breach in the piping pressure boundary. The licensee has stated, however, that if during the flow balance test, the required flow could not be achieved, the nuclear service water system train under the test would be declared inoperable and the appropriate Limiting Condition for Operating of the Technical Specifications is entered into. In addition, the condition is entered into the licensee's corrective action program for resolution. The licensee will also perform a visual examination of the ground surface areas above buried components to detect any evidence of through-wall leakage. Therefore, the licensee's proposed alternatives in RR 09-GO-001 will provide reasonable assurance of structural and leak-tight integrity. The NRC staff has determined that compliance with the ASME Code requirement would require extensive maintenance and/or system modifications requiring the installation of additional flow measuring devices at the inlet and outlet ends of buried piping. This would result in hardship to the licensee without a compensating increase in the level of quality and safety.

5.0 CONCLUSION

The NRC staff concludes that for the buried portion of the nuclear service water system at McGuire 1 and 2, compliance with the ASME Code,Section XI requirement to perform a system pressure test that determines the rate of pressure loss or the change in flow would result in hardship to the licensee without a compensating increase in the level of quality and safety. The licensee's proposed alternative does provide reasonable assurance of structural and leak-tight integrity of the buried piping. Therefore, pursuant to 10 CFR 50.55a(a)(3)(ii), the proposed alternatives in RR 09-GO-001 are authorized for the third 1O-year lSI interval for McGuire 1 and 2.

All other requirements of ASME Code,Section XI for which relief has not been specifically requested remain applicable, including a third-party review by the Authorized Nuclear Inservice Inspector.

Principal Contributor: P. Patnaik, NRR Date: February 18, 2010

R. Repko

- 2 If you have any questions concerning this action, please contact John Stang of my staff at 301-415-1345 Sincerely, IRA!

Gloria Kulesa, Chief Plant Licensing Branch 11-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-369 and 50-370

Enclosure:

Safety Evaluation cc w/encl: Distribution via Listserv DISTRIBUTION:

PUBLIC RidsRgn2MailCenter Resource LPLlI-1 RtF RidsNrrPMMcGuire Resource (hard copy)

RidsAcrsAcnw_MailCtr Resource RidsNrrDciCpnb Resource RidsNrrDorlLp2-1 Resource PPatnaik, NRR RidsNrrLAMOBrien Resource (hard copy)

DDiaz-Toro, EDO R-II ADAMS Accession No. ML100470359

  • via memo OFFICE NRRlLPL2-1/PM NRRlLPL2-1/PM NRRtLPL2-1/LA NRRlCPNB/BC NRRtLPL2-1/BC NRRtLPL2-1/PM NAME JStang JThompson MO'Brien TChan*

GKulelsa JStang DATE 2/17/10 2/17/10 2/17/10 12/24/09 2/18/10 2/18/10 OFFICIAL RECORD COpy