Text

From: Pickett, Douglas Sent: Wednesday, February 03, 2010 11:48 AM To: 'Harding Jr, Thomas' Cc: Dinsmore, Stephen; Harrison, Donnie; Patel, Jigar; Alley, David; Lupold, Timothy; Lingam, Siva; Feintuch, Karl; Salgado, Nancy

Subject:

Acceptance Review for Ginna TAC No. ME3013

Dear Mr. Harding:

By letter dated December 30, 2009, R.E. Ginna Nuclear Power Plant, LLC submitted Relief Request ISI-01 for the R.E. Ginna Nuclear Power Plant (TAC No. ME3013). The proposed relief request would adopt ASME Code Case N-716 Risk-Informed Inservice Inspection Program for Class 1 and 2 Piping. The purpose of this email is to provide the results of the Nuclear Regulatory Commission (NRC) staff=s acceptance review of this relief request. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review. The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.

Pursuant to Sections 50.55a(a)(3)(i) and 50.55a(a)(3)(ii) of Title 10 of the Code of Federal Regulations (10 CFR), the applicant shall demonstrate that the proposed alternatives would provide an acceptable level of quality and safety, or that compliance with the specified requirements of Section 50.55a would result in hardship or unusual difficulty without a compensating increase in the level of quality or safety.

The NRC staff has reviewed your application and concludes that it provides technical information in sufficient detail to enable the staff to proceed with its detailed technical review and make an independent assessment regarding the acceptability of the proposal in terms of regulatory requirements and the protection of public health and safety and the environment. If additional information is needed for the staff to complete its technical review, you will be advised by separate correspondence.

A copy of this email will be made publicly available in ADAMS. Please contact me at 301-415-1364 if you have any questions.

Douglas Pickett, Senior Project Manager Plant Licensing Branch I-1 Division of Operating Reactors Licensing Office of Nuclear Reactor Regulation E-mail Properties Mail Envelope Properties (8C658E9029C91D4D90C6960EF59FC0D607C525D6FD)

Subject:

Acceptance Review for Ginna TAC No. ME3013 Sent Date: 2/3/2010 11:48:22 AM Received Date: 2/3/2010 11:48:00 AM From: Pickett, Douglas

Created By: Douglas.Pickett@nrc.gov Recipients:

Thomas.HardingJr@constellation.com ('Harding Jr, Thomas')

Tracking Status: None Stephen.Dinsmore@nrc.gov (Dinsmore, Stephen)

Tracking Status: None Donnie.Harrison@nrc.gov (Harrison, Donnie)

Tracking Status: None Jigar.Patel@nrc.gov (Patel, Jigar)

Tracking Status: None David.Alley@nrc.gov (Alley, David)

Tracking Status: None Timothy.Lupold@nrc.gov (Lupold, Timothy)

Tracking Status: None Siva.Lingam@nrc.gov (Lingam, Siva)

Tracking Status: None Karl.Feintuch@nrc.gov (Feintuch, Karl)

Tracking Status: None Nancy.Salgado@nrc.gov (Salgado, Nancy)

Tracking Status: None Post Office:

HQCLSTR02.nrc.gov Files Size Date & Time MESSAGE 12474 2/3/2010 Options Expiration Date:

Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: