Text
F
\\
SQUTHERN CALIFORNIA Ross T. Ridenoure R1 DM SON Senior Vice President and CNO ISan Onofre Nuclear Generating Station An EDISON INTERNATIONAL@ Company SECURITY-RELATED INFORMATION Withhold from Public Disclosure in Accordance With 10 CFR 2.390 10 CFR 73.54 November 23, 2009 10 CFR 50.90 10 CFR 2.390 U.S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D.C. 20555-0001
SUBJECT:
Docket Nos. 50-361 and 50-362 Amendment Application Numbers 257 and 243 Proposed Change Number NPF-10/15-595 Cyber Security Plan San Onofre Nuclear Generating Station, Units 2 and 3 In accordance with the provisions of 10 CFR §50.4 and §50.90, Southern California Edison (SCE) hereby requests the following amendment to Facility Operating Licenses (FOL) NPF-10 and NPF-15 for the San Onofre Nuclear Generating Station (SONGS)
Units 2 and 3, respectively.
The proposed amendment requests Nuclear Regulatory Commission (NRC) approval of the SONGS Cyber Security Plan, provides an Implementation Schedule, provides a table of SONGS deviations from NEI 08-09 Revision 3, and adds a sentence to the existing FOL license condition for Physical Security to require SCE to fully implement and maintain in effect all provisions of the Commission approved Cyber Security Plan. to this letter provides the description and No Significant Hazards Analysis for the proposed amendment. Enclosure 1 also includes attachments showing the changes to the FOL. to this letter provides a copy of the SONGS Cyber Security Plan, which is a stand-alone document that will be incorporated by reference into the SONGS Physical Security Plan upon approval. SCE requests that Enclosure 2, which contains Security-Related information, be withheld from public disclosure in accordance with 10 CFR 2.390. to this letter provides a copy of the SONGS Cyber Security Plan Implementation Schedule. SCE requests that Enclosure 3, which contains Security-Related information, be withheld from public disclosure in accordance with 10 CFR 2.390.
SECURITY-RELATED INFORMATION Withhold from Public Disclosure in Accordance With 10 CFR 2.390 Mail Stop D45 (Decontrolled when separated from Enclosures 2, 3, and 4)
P.O. Box 128 San Clemente, CA 92672 (949) 368-6255 PAX 86255 Fax: (949) 368-6183 Ross.Ridenoure@sce.com
SECURITY-RELATED INFORMATION Withhold from Public Disclosure in Accordance With 10 CFR 2.390 Document Control Desk November 23, 2009 to this letter provides a copy of the SONGS Table of Deviations from NEI 08-09, Revision 3. SCE requests that Enclosure 4, which contains Security-Related information, be withheld from public disclosure in accordance with 10 CFR 2.390.
SCE has determined that there are no significant hazards considerations associated with the proposed change and that the change is exempt from environmental review pursuant to 10 CFR 51.22(c)(12).
SCE commits to the proposed implementation schedule described in Enclosure 3.
There are no other regulatory commitments associated with this request.
SCE requests an implementation period of 90 days following NRC approval of this license amendment.
If you should have any questions regarding this submittal, please contact Mr. Steven Root at 949-368-6480.
I declare under penalty of perjury that the foregoing is true and correct.
Executed on
/23 2
(Date) closure 1 - De ription and No Significant Hazards Analysis nclosure 2 - S GS Cyber Security Plan nclosure 3 - S NGS Cyber Security Plan Proposed Implementation Schedule - SONGS Table of Deviations from NEI 08-09, Revision 3 cc (with Enclosures):
R. Hall, NRC Project Manager, San Onofre Units 2 & 3 E. E. Collins, Regional Administrator, NRC Region IV G. G. Warnick, NRC Senior Resident Inspector, San Onofre Units 2 & 3 S. Y. Hsu, California Department of Public Health, Radiologic Health Branch SECURITY-RELATED INFORMATION Withhold from Public Disclosure in Accordance With 10 CFR 2.390 (Decontrolled when separated from Enclosures 2, 3, and 4)
ENCLOSURE 1 DESCRIPTION AND NO SIGNIFICANT HAZARDS ANALYSIS FOR PROPOSED CHANGE NUMBER NPF-10/15-595 SAN ONOFRE NUCLEAR GENERATING STATION, UNITS 2 AND 3
LICENSEE'S EVALUATION Description and No Significant Hazards Analysis For Proposed Change Number NPF-10/15-595 Cyber Security Plan San Onofre Nuclear Generating Station, Units 2 and 3 EXISTING OPERATING LICENSE CONDITION Unit 2: See Attachment 1 Unit 3: See Attachment 2 PROPOSED OPERATING LICENSE CONDITION (highlight for additions, strikeout for deletions)
Unit 2: See Attachment 3 Unit 3: See Attachment 4 PROPOSED OPERATING LICENSE CONDITION (with changes)
Unit 2: See Attachment 5 Unit 3: See Attachment 6 1.0
SUMMARY
DESCRIPTION The proposed license amendment request (LAR) includes the proposed San Onofre Nuclear Generating Station (SONGS) Cyber Security Plan (Plan), a proposed Implementation Schedule, a Table of Deviations from NEI 08-09, Revision 3, and a proposed sentence to be added to the existing Facility Operating License (FOL)
Physical Security license condition.
2.0 DETAILED DESCRIPTION The proposed license amendment request (LAR) includes four parts: the proposed Plan, a proposed Implementation Schedule, a Table of Deviations from NEI 08-09, Revision 3, and a proposed sentence to be added to the existing FOL Physical Security license condition to require Southern California Edison (SCE) to fully implement and maintain in effect all provisions of the Commission approved cyber security plan as required by 10 CFR §73.54. A Federal Register notice issued the final rule that Page 1 of 7
amended 10 CFR Part 73. The regulations in 10 CFR §73.54, "Protection of digital computer and communication systems and networks," establish the requirements for a cyber security program. This regulation specifically requires each licensee currently licensed to operate a nuclear power plant under Part 50 of this chapter to submit a cyber security plan that satisfies the requirements of the Rule. Each submittal must include a proposed implementation schedule and implementation of the licensee's cyber security program must be consistent with the approved schedule.
3.0 TECHNICAL EVALUATION
Federal Register notice 74 FR 13926 (Reference 1) issued the final rule that amended 10 CFR Part 73. Cyber security requirements are codified as new §73.54 and are designed to provide high assurance that digital computer and communication systems and networks are adequately protected against cyber attacks up to and including the design basis threat established by § 73.1(a)(1)(v). These requirements are substantial improvements upon the requirements imposed by EA-02-026 (Reference 2).
This LAR includes the proposed Plan (Enclosure 2) that conforms to the template provided in NEI 08-09, Revision 3. In addition, the LAR includes the proposed change to the existing FOL license condition for "Physical Security" (Attachments 3, 4, 5, and 6). The LAR contains the proposed Implementation Schedule (Enclosure 3) as required by 10 CFR §73.54. Finally, the LAR contains a Table of Deviations from NEI 08-09, Revision 3 (Enclosure 4).
4.0 REGULATORY EVALUATION
4.1 APPLICABLE REGULATORY REQUIREMENTS / CRITERIA This LAR is submitted pursuant to 10 CFR §73.54 which requires licensees currently licensed to operate a nuclear power plant under 10 CFR Part 50 to submit a Cyber Security Plan as specified in §50.4 and §50.90.
Page 2 of 7
4.2 SIGNIFICANT HAZARDS CONSIDERATION SCE has evaluated the proposed changes using the criteria in 10 CFR 50.92 and has determined that the proposed changes do not involve a significant hazards consideration. An analysis of the issue of no significant hazards consideration is presented below:
Criterion 1: The proposed change does not involve a significant increase in the probability or consequences of an accident previously evaluated.
The proposed change is required by § 73.54 and includes four parts. The first part is the submittal of the Plan for NRC review and approval. The Plan conforms to the template provided in NEI 08-09, Revision 3, and provides a description of how the requirements of the Rule will be implemented at SONGS. The Plan establishes the licensing basis for the SONGS Cyber Security Program. The Plan establishes how to achieve high assurance that nuclear power plant digital computer and communication systems and networks associated with the following are adequately protected against cyber attacks up to and including the design basis threat:
- 1. Safety-related and important-to-safety functions,
- 2. Security functions,
- 3. Emergency preparedness functions including offsite communications, and
- 4. Support systems and equipment which if compromised, would adversely impact safety, security, or emergency preparedness functions.
Part one of the proposed change is designed to achieve high assurance that the systems are protected from cyber attacks. The Plan itself does not require any plant modifications. However, the Plan does describe how plant modifications that involve digital computer systems are reviewed to provide high assurance of adequate protection against cyber attacks, up to and including the design basis threat as defined in the Rule.
The proposed change does not alter the plant configuration, require new plant equipment to be installed, alter accident analysis assumptions, add any initiators, or affect the function of plant systems or the manner in which systems are operated, maintained, modified, tested, or inspected. The first part of the proposed change is Page 3 of 7
designed to achieve high assurance that the systems within the scope of the Rule are protected from cyber attacks and has no impact on the probability or consequences of an accident previously evaluated.
The second part of the proposed change is a proposed Implementation Schedule (provided as Enclosure 3). The third part adds a sentence to the existing FOL license condition for Physical Security. The fourth part provides a Table of Deviations from NEI 08-09, Revision 3. All of these changes are administrative and have no impact on the probability or consequences of an accident previously evaluated.
Therefore, it is concluded that this change does not involve a significant increase in the probability or consequences of an accident previously evaluated.
Criterion 2: The proposed change does not create the possibility of a new or different kind of accident from any accident previously evaluated.
The proposed change is required by § 73.54 and includes four parts. The first part is the submittal of the Plan for NRC review and approval. The Plan conforms to the template provided by NEI 08-09, Revision 3, and provides a description of how the requirements of the Rule will be implemented at SONGS. The Plan establishes the licensing basis for the SONGS Cyber Security Program. The Plan establishes how to achieve high assurance that nuclear power plant digital computer and communication systems and networks associated with the following are adequately protected against cyber attacks up to and including the design basis threat:
- 1. Safety-related and important-to-safety functions,
- 2. Security functions,
- 3. Emergency preparedness functions including offsite communications, and
- 4. Support systems and equipment which if compromised, would adversely impact safety, security, or emergency preparedness functions.
Part one of the proposed change is designed to achieve high assurance that the systems within the scope of the Rule are protected from cyber attacks. The Plan itself Page 4 of 7
does not require any plant modifications. However, the Plan does describe how plant modifications that involve digital computer systems are reviewed to provide high assurance of adequate protection against cyber attacks, up to and including the design basis threat as defined in the Rule. The proposed change does not alter the plant configuration, require new plant equipment to be installed, alter accident analysis assumptions, add any initiators, or affect the function of plant systems or the manner in which systems are operated, maintained, modified, tested, or inspected. The first part of the proposed change is designed to achieve high assurance that the systems within the scope of the Rule are protected from cyber attacks and does not create the possibility of a new or different kind of accident from any previously evaluated.
The second part of the proposed change is a proposed Implementation Schedule. The third part adds a sentence to the existing FOL license condition for Physical Security.
The fourth part provides a Table of Deviations from NEI 08-09, Revision 3. All of these changes are administrative and do not create the possibility of a new or different kind of accident from any previously evaluated.
Therefore, the proposed change does not create the possibility of a new or different kind of accident from any previously evaluated.
Criterion 3: The proposed change does not involve a significant reduction in a margin of safety.
The proposed change is required by § 73.54 and includes four parts. The first part is the submittal of the Plan for NRC review and approval. The Plan conforms to the template provided by NEI 08-09, Revision 3, and provides a description of how the requirements of the Rule will be implemented at SONGS. The Plan establishes the licensing basis for the SONGS Cyber Security Program. The Plan establishes how to achieve high assurance that nuclear power plant digital computer and communication Page 5 of 7
systems and networks associated with the following are adequately protected against cyber attacks up to and including the design basis threat:
- 1. Safety-related and important-to-safety functions,
- 2. Security functions,
- 3. Emergency preparedness functions including offsite communications, and
- 4. Support systems and equipment which if compromised, would adversely impact safety, security, or emergency preparedness functions.
Part one of the proposed change is designed to achieve high assurance that the systems within the scope of the Rule are protected from cyber attacks. Plant safety margins are established through Limiting Conditions for Operation, Limiting Safety System Settings and Safety limits specified in the Technical Specifications. Because there is no change to these established safety margins, the proposed change does not involve a significant reduction in a margin of safety.
The second part of the proposed change is a proposed Implementation Schedule (provided as Enclosure 3). The third part adds a sentence to the existing FOL license condition for Physical Security. The fourth part provides a Table of Deviations from NEI 08-09, Revision 3. All of these changes are administrative and do not involve a significant reduction in a margin of safety.
Therefore, the proposed change does not involve a significant reduction in a margin of safety.
Based on the above, SCE concludes that the proposed change presents no significant hazards consideration under the standards set forth in 10 CFR 50.92(c), and accordingly, a finding of no significant hazards consideration is justified.
4.3 CONCLUSION
Based on the considerations discussed above, it is concluded that: (1) there is reasonable assurance that the health and safety of the public will not be endangered by Page 6 of 7
operation in the proposed manner; (2) such activities will be conducted in compliance with the Commission's regulations; and (3) the issuance of the amendment will not be inimical to the common defense and security or to the health and safety of the public.
5.0 ENVIRONMENTAL CONSIDERATION
The proposed amendment establishes the licensing basis for a Cyber Security Program for SONGS and will be a part of the Physical Security Plan. This proposed amendment will not involve any significant construction impacts. Pursuant to 10 CFR 51.22(c)(12) no environmental impact statement or environmental assessment need be prepared in connection with the issuance of the amendment.
6.0 REFERENCES
- 1. Federal Register Notice, Final Rule 10 CFR Part 73, Power Reactor Security Requirements, published on March 27, 2009, 74 FR 13926.
- 2. EA-02-026, Order Modifying Licenses, Safeguards and Security Plan Requirements, issued February 25, 2002.
- 3. NEI 08-09, Revision 3, "Cyber Security Plan Template."
Page 7 of 7
PCN 595 Attachment I SONGS Unit 2 Existing Pages: Facility Operating License E.
SCE shall fully implement and maintain in effect all provisions of the Commission-approved physical security, training and qualification, and safeguards contingency plans including amendments made pursuant to provisions of the Miscellaneous Amendments and Search Requirements revisions to 10 CFR 73.55 (51 FR 27817 and 27822) and to the authority of 10 CFR 50.90 and 10 CFR 50.54(p).
The combined set of plans, which contain Safeguards Information protected under 10 CFR 73.21 is entitled: "San Onofre Nuclear Generating Station Security, Training and Qualification, and Safeguards Contingency Plan, Revision 0" submitted by letter dated October 19, 2004.
F.
This license is subject to the following additional condition for the protection of the environment:
Before engaging in activities that may result in a significant adverse environmental impact that was not eva uated or that is significantly greater than that evaluated in the Final Environmental Statement, SCE shall provide a written notification of such activities to the NRC Office of Nuclear Reactor Regulation and receive written approval from that office before proceeding with such activities.
G.
DELETED H.
SCE shall notify the Commission, as soon as possible but not later than one hour, of any accident at this facility which could result in an unplanned release of quantities of fission products in excess of allowable limits for normal operation established by the Commission.
I.
SCE shall have and maintain financial protection-of such type.and in such amounts as the Commission shall require in accordance withý Section 170 of the Atomic Energy Act of 1954, as amended, to cover public liability claims.
J.
This license is effective as of the date of issuance and shall expire at midnight on February 16, 2022.
FOR THE NUCLEAR REGULATORY COMMISSION Original Signed by Harold R. Denton Harold R. Denton, Director Office of Nuclear Reactor Regulation
Enclosures:
- 1.
Appendix A (Technical Specifications)
- 2.
Appendix B (Environmental Protection Plan)
- 3.
Appendix C (Antitrust Conditions)
Date of Issuance:
FEB 16 1982 On September 29, 1983, the Safeguards Contingency Plan was made a separate, companion document to the Physical Security Plan pursuant to the authority of 10 CFR 50.54.
Amendment No.
214 Revised by letter dated March 6, 2007
PCN 595 SONGS Unit 3 Existing Pages: Facility Operating License Report.
These exemptions are authorized by law and will not endanger life or property or the common defense and security and are otherwise in the public interest. Therefore, these exemptions are hereby granted. The facility will operate, to the extent authorized ierei in conformity with the application, as amended, the provisions of te Act, and the regulations of the Commission.
E.
SCE shall fully implement and maintain in effect all provisions of the Commission-approved physical security, training and qualification, and safeguards contingency plans including amendments made pursuant to provisions of the Miscellaneous Amendments and Search Requirements revisions to 10 CFR 73.55 (51 FR 271a7 and 27822) and to the authority of 10 CFR 50.90 and 10 CF 50.54(p).
The combined set of plans, which contain Safeguards Information protected under 10 CFR 73.21 is entitled: "San Onofre Nuclear Generating Station Security, Training and Qualification, and Safeq uards Contingency Plan, Revision 0" submitted by letter dated October 19, 2004.
F.
This license is subject to the following additional condition for the protection of the environment:
Before engaging in activities that may result in a significant adverse environmental impact that was not evaluated or that is significantly greater than that evaluated in the Final Environmental Statement, SCE shall provide a written notification of such activities to the NRC Office of Nuclear Reactor Regulation and receive written approval from that office before proceeding with such activities.
G.
DELETED H.
SCE shall notify the Commission, as soon as possible but not later than one hour, of any accident at this facility which could result in an unplanned release of quant-ities of fission products in excess of allowable limits for normal operation established by the Commission.
I.
SCE shall have and maintain financial protection of such type and in such amounts as the Commission shall require in accordance with Section 170 of the Atomic Energy Act of 1954, as amended, to cover public liability claims.
J.
This license is effective as of the date of issuance and shall expire at midnight on November 15, 2022.
K.
Deleted by Amendment No.
176 FOR THE NUCLEAR REGULATORY COMMISSION Original Signed by Harold R. Denton Harold R. Denton, Director Office of Nuclear Reactor Regulation Attachments:
- 1.
Attachment I - Deleted by Amendment No.
176
- 2.
Appendix A (Technical Specifications)
- 3.
Appendix B (Environmental Protection Plan)
- 4.
Appendix C (Antitrust Conditions)
Date of Issuance:
NOV 15 1982 On September 29, 1983, the Safeguards Contingency Plan was made a separate, companion document to the Physical Security Plan pursuant to the authority of 10 CFR 50.54.
Amendment No.
206 Revised by letter dated March 6, 2007
PCN 595 SONGS Unit 2 Retyped: Facility Operating License E.
SCE shall fully implement and maintain in effect all provisions of the Commission-approved physical security, training and qualification, and safeguards contingency plans including amendments made pursuant to provisions of the Miscellaneous Amendments and Search Requirements revisions to 10 CFR 73.55 (51 FR 27817 and 27822) and to the authority of 10 CFR 50.90 and 10 CFR 50.54(p).
The combined set of plans, which contain Safeguards Information protected under 10 CFR 73.21 is entitled:
"San Onofre Nuclear Generating Station Security, Training and Qualification and Safeguards Contingenc Pla F.
This license is sub ject to the following additional condition for the protection of the environment:
Before engaging in activities that may result in a significant adverse environmental impact that was not evaluated or that is significantly qreater than that evaluated in the Final Environmental Statement.
SCE shall provide a written notification of such activities to t6e NRC Office of Nuclear Reactor Regulation and receive written.approval from that.office before proceeding with such activities.
G.
DELETED H.
SCE shall notify the,Commission, as soon as possible but not later than one hour, of any accident at this-facility which could result in an unplanned release of quantities of fission products in excess of allowable limits for normal operation established by the Commission.
I.
SCE shall have and maintain financial protection of such type and in such amounts as the Commission shall require in accordance with Section 170 of the Atomic Energy Act of 1954, as amended, to cover public liability claims.
J.
This license is effective as of the date of issuance and shall expire at midnight on February 16, 2022.
FOR THE NUCLEAR REGULATORY COMMISSION Original Signed by Harold R. Denton Harold R. Denton, Director Office of Nuclear Reactor Regulation
Enclosures:
- 1.
Appendix A (Technical Specifications)
- 2.
Appendix B (Environmental Protection Plan)
- 3.
Appendix C (Antitrust Conditions)
Date of Issuance:
FEB 16 1982 On September 29, 1983, the Safeguards Contingency Plan was made a separate, companion document to the Physical Security Plan pursuant to the authority of 10 CFR 50.54.
Amendment No. 24 Revised by letter dated March 6, 2007
PCN 595 SONGS Unit 3 Retyped: Facility Operating License Report.
These exemptions are authorized by law and will not endanger life or property or the common defense and security and are otherwise in the public interest. Therefore, these exemptions are hereby granted. The facility will operate, to the extent authorized herein, in conformity with the application, as
- amended, the provisions of the Act, and the regulations of the Commission.
E.
SCE shall fully implement and maintain in effect all provisions of the Commission-approved physical security, training and qualification, and safeguards contingency plans including amendments made pursuant to provisions of the Miscellaneous Amendments and Search Requirements revisions to 10 CFR 73.55 (51 FR 27817 and 27822) and to the authority of 10 CFR 50.90 and 10 CFR 50.54(p).
The combined set of plans, which contain Safeguards Information protected under 10 CFR. 73.21 is entitled:
"San Onofre Nuclear Generating Station Security, Training and Qualification, and Safeguards Contingency Pla I
F.
This license is subject to the following additional condition for the protection of the environment:
Before engaging in activities that may result in a significant adverse environmental impact that was not evaluated or that is significantly greater than that evaluated in the Final Environmental Statement, SCE shall provide a written notification of such activities to the NRC Office of Nuclear Reactor Regulation and receive written approval from that office before proceeding with such activities.
G.
DELETED H.
SCE shall notify the Commission, as soon as possible but'not later
.than one hour, of any accident at this facility which could result in an unplanned release of quantities of'fission roducts in excess of allowable limits for normal operation established by the.
Commission.
I.
SCE shall have and maintain financial protection of such type and in such amounts as the Commission shall require in accordance with Section 170 of the Atomic Energy Act of 19 54, as amended, to cover public liability claims.
On September 29, 1983, the Safeguards ContingencyPlan was made a separate, companion document to the Physical Security Plan pursuant to the authority of 10 CFR 50.54.
Amendment No. 9 Revised by letter dated March 6, 2007 J.
This license is effective as of the date of*issuance and.shall expire at midnight on November 15, 2022.
K.
Deleted by Amendment No.
176 FOR THE NUCLEAR REGULATORY COMMISSION Original Signed by Harold R. Denton Harold R. Denton, Director Office of Nuclear Reactor Regulation Attachments:
- 1.
Attachment I - Deleted by Amendment No.
176
- 2.
Appendix A (Technical Specifications)
- 3.
Appendix B (Environmental Protection Plan)
- 4.
Appendix C (Antitrust Conditions)
Date of Issuance:
NOV 15 1982 Amendment No. 2 Revised by letter dated Mareh 6, 2007
PCN 595 SONGS Unit 2 Clean Pages: Facility Operating License E.
SCE shall fully implement and maintain in effect all provisions of
.the Commission-approved physical security, training and qualification, and safeguards contingency plans including amendments made pursuant to provisions of the Miscellaneous Amendments and Search Requirements revisions to 1O'CFR 73.55 (51 FR 27817 and 27822) and to the authority of 10 CFR 50.90 and 2 CFR 50.54(p).
The combined set of plans, which contain Safeguards Information protected under 10 CFR 73.21 is entitled:
"San Onofre Nuclear Generating Station Security, Training and Qualification and Safeguards Contingency Plan Revision 0" submitted by letter dated October 19, 2004.
SCE shall'fully implement and maintain in effect all provisions of the Commission-approved SONGS Cyber Security Plan submitted by letter dated November.23 2009 and withheld from public disclosure in accordance with 16 CFR §2.390.
F.
This license is subject to the following additional condition for the protection of the environment:
Before engaging in activities that may result in a significant adverse environmental impact that was not evaluated or that is significantly greater than that evaluated in the Final Environmental Statement SCE shall provide a written notification of such activities to thie NRC Office of Nuclear Reactor Regulation and receive written approval from that office before proceeding with such activities.
G.
DELETED H.
SCE shall notify the Commission, as soon as possible but not later
,than one 'hour, of any accident at this facility which could.,ire~s-ul-t in an unplanned release of quantities of fission products in'excess of allowable limits for normal operation established by the Commission.
I.
SCE shall have and maintain financial protection of such type and in such amounts as the Commission shall require in accordance with Section 170 of the Atomic Energy Act of 1954, as amended,'to cover public liability claims.
J.
This license is effective as of the date Of issuance and shall' expire at midnight on February 16, 2022.
FOR THE NUCLEAR REGULATORY COMMISSION Original Signed by Harold R. Denton Harold R. Denton, Director Office of Nuclear Reactor Regulation
Enclosures:
1.-
Appendix A (Technical Specifications)
- 2.
Appendix B (Environmental Protection Plan)
- 3.
Appendix C (Antitrust Conditions)
Date of Issuance:
FEB 16 1982 On September 29, 1983, the Safeguards Contingen'cy Pl.an was made a separate, companion document to the Physical Security Plan pursuant to the authority of 10 CFR 50.54.
1 Amendment No.
PCN 595 SONGS Unit 3 Clean Pages: Facility Operating License Report.
These exemptions are authorized *by law and will not endanger life or property or the common defense and security and are otherwise in the public interest. Therefore, these exemptions are hereby granted. The facility will operate, to the extent authorized herein, in conformity with the application, as
- amended, the provisions of the Act, and the regulations of the Commission.
E.
SCE shall fully implement and maintain in effect all provisions of
- the Commission-approved physical security, training and qualification, and safeguards contingency plans including amendments made pursuant to provisions of the Miscellaneous Amendments and Search Requirements revisions to 10 CFR 73.55 (51 FR 27817 and 27822) and to the authority of 10 CFR 50.90 and 10 CFR 50.54(p).
The combined set of plans, which contain Safeguards Information protected under 10 CFR 73.21 is entitled:
"San Onofre Nuclear Generating Station Security, Training and Qualification, and Safeguards Contingency Plan, Revision 0" submitted by letter dated October 19, 2004.
SCE shall fully implement and maintain in effect all provisions of the Commission-approved SONGS Cyber Security Plan submitted by letter dated November 23, 2009 and withheld from public disclosure in accordance with 10 CFR §2.390.
F.
This license is subject to the following additional condition for the protection of the environment:
Before engaging in activities that may result in a significant adverse environmental impact that was not evaluated or that i~s..
significantly greater than that evaluated in the Final Environmental Statement, SCE shall provide a written notification of such activities to the NRC Office of Nuclear Reactor Regulation and receive written approval from that office before proceeding with such activities.
G.
DELETED H.
SCE shall notify the Commission, as soon as possible but not later than one hour, of any accident at this facility which could result in an unplanned release of quantities of fission products in excess of allowable limits for normal operation established by the Commission.
I.
SCE shall have and maintain financial protection of such type and in such amounts as the Commission shall require in accordance with Section 170 of the Atomic Energy Act of 1954, as amended, to cover public liability claims.
On September 29, 1983, the Safeguards Contingency Plan was made a separate, companion document to the Physical Security Plan pursuant to the authority of 10 CFR 50.54.
Amendment No.
J.
This license is effective as of the date of issuance and shall expire at midnight on November 15, 2022.
K.
Deleted by Amendment No.
176 FOR THE NUCLEAR REGULATORY COMMISSION Original Signed by Harold R. Denton Harold R. Denton, Director Office of Nuclear Reactor Regulation Attachments:
- 1. Attachment I - Deleted by Amendment No.
176
- 2.
Appendix A (Technical Specifications)
- 3.
Appendix B (Environmental Protection Plan)
- 4.
Appendix C (Antitrust Conditions)
Date of Issuance:
NOV 15 1982 Amendment No.