ML093100149

From kanterella
Jump to navigation Jump to search

Relief Request for Containment Building Spray Pump Flow Test
ML093100149
Person / Time
Site: Seabrook 
Issue date: 11/06/2009
From: Egan D
Plant Licensing Branch 1
To: O'Keefe M
Florida Power & Light Energy Seabrook
Egan, Dennis; NRR/DORL 301-415-2443
References
TAC ME2412
Download: ML093100149 (2)


Text

From:

Egan, Dennis Sent:

Friday, November 06, 2009 9:50 AM To:

'OKeefe, Michael' Cc:

Wolfgang, Robert; Farnan, Michael; Feintuch, Karl; Lingam, Siva

Subject:

Acceptance Review for Containment Building Spray Pump Flow Test Relief Request (ME2412)

ADAMSAccessionNumber:

ML090420020 Mr. O'Keefe:

By letter dated October 13, 2009, NextEra Energy Seabrook submitted a relief request for the Seabrook Station, Unit No. 1. The relief request provides an alternative for the Containment Building Spray Pump Flow Test (TAC No. ME2412). The purpose of this e-mail is to provide you with the results of the Nuclear Regulatory Commission (NRC) staff's acceptance review of this submittal. The acceptance review was performed to determine if there is sufficient technical information in scope and depth to allow the NRC staff to complete its detailed technical review.

The acceptance review is also intended to identify whether the application has any readily apparent information insufficiencies in its characterization of the regulatory requirements or the licensing basis of the plant.

Pursuant to Sections 50.55a(a)(3)(i) and 50.55a(a)(3)(ii) of Title 10 of the Code of Federal Regulations (10 CFR), the applicant shall demonstrate that the proposed alternative would provide an acceptable level of quality and safety, or that compliance with the specified requirements of Section 50.55a would result in hardship or unusual difficulty without a compensating increase in the level of quality or safety.

The NRC staff has reviewed your submittal and concluded that it does provide technical information in sufficient detail to enable the NRC staff to proceed with its detailed technical review and make an independent assessment regarding the acceptability of the proposed relief request in terms of regulatory requirements and protection of public health and safety and the environment. Given the lesser scope and depth of the acceptance review as compared to the detailed technical review, there may be instances in which issues that impact the NRC staffs ability to complete the detailed technical review are identified despite completion of an adequate acceptance review. If additional information is needed, you will be advised by separate correspondence.

If you have any questions, please contact me.

Dennis Egan, P.E.

Senior Project Manager U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Division of Operating Reactor Licensing Plant Licensing Branch LPL1-2 (301) 415-2443 dennis.egan@nrc.gov

E-mail Properties Mail Envelope Properties (9E28710E0B702149AEC663972863644019C1560BBB)

Subject:

Acceptance Review for Containment Building Spray Pump Flow Test Relief Request (ME2412)

Sent Date: 11/5/2009 10:34:18 AM Received Date: 11/6/2009 9:50:00 AM From: Egan, Dennis Created By: Dennis.Egan@nrc.gov Recipients:

Michael.OKeefe@fpl.com ('OKeefe, Michael')

Tracking Status: None Robert.Wolfgang@nrc.gov (Wolfgang, Robert)

Tracking Status: None Michael.Farnan@nrc.gov (Farnan, Michael)

Tracking Status: None Karl.Feintuch@nrc.gov (Feintuch, Karl)

Tracking Status: None Siva.Lingam@nrc.gov (Lingam, Siva)

Tracking Status: None Post Office:

HQCLSTR01.nrc.gov Files Size Date & Time MESSAGE 14278 11/5/2009 Options Expiration Date:

Priority: olImportanceNormal ReplyRequested: False Return Notification: False Sensitivity: olNormal Recipients received: