8/11/09 Prairie Island Request for Information
ML092240559
Person / Time
Site: Prairie Island Xcel Energy icon.png
Issue date: 08/11/2009
From:
NRC/RGN-III
To:
References
Download: ML092240559 (2)


Text

Prairie Island Unit 1 - Supplemental Document Request to Support Baseline ISI inspection procedure 71111.08. Please provide the inspector (M. Holmberg) with the following documents at the on-site inspection entrance meeting scheduled for September 14, 2009. Additionally, please provide confined space, fall protection, and FME training for (Melvin Holmberg and Atif Shaikh) on September 15, 2009 to support observation of NDE examinations.

Welds Selected for Review:

WO/Weld No Description & System Supporting Docs.

PO # 21572, Item 1-25-014 Cooling Water (CL)

Class 3 (In-Process welding)

Weld build up on Suction Bells, column pipe flanges, discharge elbow, and connector pipe.

Replaced lower column pipe.

1) NRC information request letter dated July 8, 2009, Paragraph B.1 documents.
2) Copy of applicable construction code and material specifications (ASTM, ASME etc) for use by inspector for duration of inspection.
3) Vendor fabrication drawings for affected components.

WO #100611-07, Item 1-24-059 Cooling Water (CL),

Class 3 Weld Buildup of wasted areas of shell and attachment weld areas.

1) NRC information request letter dated July 8, 2009, Paragraph B.1 documents.
2) Copy of applicable construction code and material specifications (ASTM, ASME etc) for use by inspector for duration of inspection.
3) Vendor fabrication drawings for affected components.

WO#304392-01 Item 1-24-054, Reactor Coolant System (RC)

Class 1 Installed new isolation valve (RC-8-42 pzr loop seal drain valve) and replaced associated piping.

1) NRC information request letter dated July 8, 2009, Paragraph B.1 documents.

2)EC-11442 (descriptions and drawings)

3) B31.1 Code 1967 Edition for use by inspector for duration of inspection.

Corrective Action Documents Selected for Review:

Number Title Supplemental Information AR-01151962 Pinhole leak at weld on Pipe 8-2CL-25 Operability evaluation and completed WO that repaired pipe AR-01167225 Missing Insulation and Rust on Inlet to 22 CC HX Apparent/root cause if performed.

CAP-1152070 Double Spring Can Hanger Binding Code Examination report, component drawing, vendor manual and basis for functionality (accepted as is) if not recorded on CR.

CAP-1152093 Load indicator more than 10 percent out of tolerance.

Site procedures used to evaluate acceptability of spring can supports, applicable to this type of support. Code Exam report, drawing and vendor manual.

CAP-1128000 FME on reactor head flange Apparent/root cause if performed.

CAP-1140763 FME found in 12 RHR pit heat exchanger Apparent/root cause if performed.

Summary Report 501615-R1 Elbow to Valve Weld W-6 Provide latest UT exam reports for welds W-5 and W-6 and procedure for approving weld substitutions.