ML092100133

From kanterella
Jump to navigation Jump to search
Submittal of Special Report (Spr) 09-0001
ML092100133
Person / Time
Site: Summer South Carolina Electric & Gas Company icon.png
Issue date: 07/24/2009
From: Archie J
South Carolina Electric & Gas Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML092100133 (1)


Text

Jeffrey B. Archie Vice President,NuclearOperations 803.345.4214 July 24, 2009 A SCANA COMPANY Document Control Desk U. S. Nuclear Regulatory Commission Washington, DC 20555

Dear Sir / Madam:

Subject:

VIRGIL C. SUMMER NUCLEAR STATION (VCSNS)

DOCKET NO. 50/395 OPERATING LICENSE NO. NPF-12 SPECIAL REPORT (SPR) 09-0001 South Carolina Electric & Gas Company (SCE&G) is submitting this report pursuant to the requirements of Technical Specification (TS) 3.3.3.6 a., Table 3.3-10, Items 6 and 11. This report addresses the inoperability of the Reactor Coolant Loop "C" Hot Leg Temperature Element ITE00433. The temperature element supports part of the accident monitoring instrumentation required by NUREG-0737 item II.F.2.

ITE00433 was declared inoperable June 12, 2009, at 0430 hours0.00498 days <br />0.119 hours <br />7.109788e-4 weeks <br />1.63615e-4 months <br /> due to spurious alarms.

VCSNS diagnostics indicated the cause of the erroneous readings is associated with the element and not with supporting components. Preplaned alternate methods of obtaining accurate readings are provided through the remaining channel of Reactor Coolant Outlet Temperature (Wide Range) and Reactor Vessel Level Instrumentation System. ITE00433 is a dual element RTD. Its sister element ITE00433A is operable and provides Reactor Coolant System Hot Leg "C" wide range temperature indication at the Control Room Evacuation Panel (CREP) and Technical Support Center (TSC). Due to the location of the element, restoration of channel operability cannot be completed until the next available outage.

The failure of the element has been entered into the VCSNS corrective action program and planned for replacement at the next opportunity. Should you have any questions, please call Mr. Bruce Thompson at (803) 931-5042 at your convenience.

Very truly yours, Jfey. Achie JMG/JHW/JBA/gar c: K. B. Marsh S. A. Byrne K. M. Sutton N. S. Carns NRC Resident Inspector J. H. Hamilton INPO Records Center R. J. White NSRC W. M. Cherry RTS (CR-09-02337)

L. A. Reyes File (818.08)

R. E. Martin PRSF (RC-09-0082)

SCE&G I Virgil C.Summer Nuclear Station

  • P.O.Box 88 ° Jenkinsville, South Carolina 29065 °T (803) 345.5209 °www.scana.com ,.1 e .