ML091910196

From kanterella
Jump to navigation Jump to search
Summary of Telephone Conference Call Held on June 25, 2009, Between the U.S. NRC and PPL Susquehanna, LLC, Comments on the Safety Evaluation Report with Open Items Related to the License Renewal of Susquehanna Steam Electric Station, Units
ML091910196
Person / Time
Site: Susquehanna  
Issue date: 07/16/2009
From: Gettys E
License Renewal Projects Branch 1
To:
Susquehanna
Gettys Evelyn, NRR/DLR/RPB1 415-4029
References
Download: ML091910196 (3)


Text

July 16, 2009 LICENSEE: PPL Susquehanna, LLC FACILITY: Susquehanna Steam Electric Station, Units 1 and 2

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON JUNE 25, 2009, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PPL SUSQUEHANNA, LLC, COMMENTS ON THE SAFETY EVALUATION REPORT WITH OPEN ITEMS RELATED TO THE LICENSE RENEWAL OF SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 The U.S. Nuclear Regulatory Commission (NRC or the staff) and representatives of PPL Susquehanna, LLC (PPL), held a telephone conference call on June 25, 2009, to discuss PPLs comments on the Safety Evaluation Report with open items related to the license renewal of Susquehanna Steam Electric Station, Units 1 and 2 (SSES), issued by letter of March 13, 2009.

The NRC staff stated in its write up concerning request for additional information 4.3-1b that the number of cycles for the 25 percent steam bypass event was 70 cycles. The purpose of the telephone conference call was for PPL to clarify that the SSES design basis includes 70 cycles for the partial feedwater heater bypass event and 10 cycles for the turbine trip with 25 percent steam bypass event.

The enclosure provides a listing of the participants.

The applicant had an opportunity to comment on this summary.

/RA/

Evelyn H. Gettys, Project Manager Projects Branch 1 Division of License Renewal Office of Nuclear Reactor Regulation Docket Nos. 50-387 and 50-388

Enclosure:

As stated cc w/encl: See next page

ML091910196 OFFICE PM:RPB1:DLR LA:DLR BC:RPB1:DLR PM:RPB1:DLR NAME EGettys IKing DPelton (DAshley for)

EGettys (Signature)

DATE 07/16/09 07/15/09 07/16/09 07/16/09

Memorandum to PPL Susquehanna, LLC from Evelyn H. Gettys dated July 16, 2009

SUBJECT:

SUMMARY

OF TELEPHONE CONFERENCE CALL HELD ON JUNE 25, 2009, BETWEEN THE U.S. NUCLEAR REGULATORY COMMISSION AND PPL SUSQUEHANNA, LLC, COMMENTS ON THE SAFETY EVALUATION REPORT WITH OPEN ITEMS RELATED TO THE LICENSE RENEWAL OF SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 DISTRIBUTION:

HARD COPY:

DLR RF E-MAIL:

PUBLIC RidsNrrDlr Resource RidsNrrDlrRpb1 Resource RidsNrrDlrRpb2 Resource RidsNrrDlrRerb Resource RidsNrrDlrRer1 Resource RidsNrrDlrRer2 Resource RidsNrrDlrRpob Resource RidsNrrDciCvib Resource RidsNrrDciCpnb Resource RidsNrrDraAfpb Resource RidsNrrDeEmcb Resource RidsNrrDeEeeb Resource RidsNrrDssSrxb Resource RidsNrrDssSbpb Resource RidsNrrDssScvb Resource RidsOgcMailCenter Resource EGettys FJaxheimer

ENCLOSURE TELEPHONE CONFERENCE CALL SUSQUEHANNA STEAM ELECTRIC STATION, UNITS 1 AND 2 LICENSE RENEWAL APPLICATION LIST OF PARTICIPANTS June 25, 2009 PARTICIPANTS AFFILIATIONS Evelyn Gettys U.S. Nuclear Regulatory Commission (NRC)

Allen Hiser NRC Chuang-Yeh Yang NRC Duane Filchner PPL Susquehanna, LLC (PPL)

Dave Flyte PPL Jeff Weik PPL

Susquehanna Steam Electric Station, Units 1 and 2 cc:

Cornelius J. Gannon Vice President - Nuclear Operations PPL Susquehanna, LLC 769 Salem Blvd., NUCSB3 Berwick, PA 18603-0467 Robert M. Paley General Manager - Plant Support PPL Susquehanna, LLC 769 Salem Blvd., NUCSB2 Berwick, PA 18603-0467 Michael H. Crowthers Manager - Nuclear Regulatory Affairs PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Ronald E. Smith General Manager - Site Preparedness and Services PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467 Michael H. Rose Manager - Quality Assurance PPL Susquehanna, LLC 769 Salem Blvd., NUCSB2 Berwick, PA 18603-0467 Joseph J. Scopelliti Community Relations Manager, Susquehanna PPL Susquehanna, LLC 634 Salem Blvd., SSO Berwick, PA 18603-0467 Board of Supervisors Salem Township P.O. Box 405 Berwick, PA 18603-0035 Bryan A. Snapp, Esq.

Associate General Counsel PPL Services Corporation Two North Ninth Street, GENTW3 Allentown, PA 18101-1179 Document Control Services PPL Susquehanna, LLC Two North Ninth Street, GENPL4 Allentown, PA 18101-1179 Richard W. Osborne Allegheny Electric Cooperative, Inc.

212 Locust Street P.O. Box 1266 Harrisburg, PA 17108-1266 Director, Bureau of Radiation Protection Pennsylvania Department of Environmental Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 35, NUCSA4 Berwick, PA 18603-0035 Regional Administrator, Region 1 U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Dr. Judith Johnsrud National Energy Committee Sierra Club 443 Orlando Avenue State College, PA 16803 Dayne R. Brophy Nuclear Regulatory Affairs PPL Susquehanna, LLC 769 Salem Blvd., NUCSA4 Berwick, PA 18603-0467