ML091460618
| ML091460618 | |
| Person / Time | |
|---|---|
| Site: | Oyster Creek |
| Issue date: | 10/01/2008 |
| From: | Richmond J NRC Region 1 |
| To: | Modes M NRC Region 1 |
| References | |
| FOIA/PA-2009-0070 | |
| Download: ML091460618 (6) | |
Text
Jbhn'Riichmond From:
Sent:
To:
Subject:
Attachments:
John Richmond, *1*'T Wednesday, October 01, 2008 12:28 PM Michael Modes OC High Priority Insp Items OC Priority Inspection Itemsrev-4.doc see attached this is intended to be the core of our inspection.
I wanted to look at the SER list and the outage work list, to see if we can broaden the targeted inspection samples to cover more aging management programs. [e.g., verify more commitments]. just haven't found the time yet.
I
Received: from R1CLSTR01.nrc.gov ([148.184.99.7]) by R1 MS01.nrc.gov
([148.184.99.10]) with mapi; Wed, 1 Oct 2008 12:27:35 -0400 Content-Type: application/ms-tnef; name="winmail.dat" Content-Transfer-Encoding: binary From: John Richmond <John.Richmond@nrc.gov>
To: Michael Modes <MichaeI.Modes@nrc.gov>
Date: Wed, 1 Oct 2008 12:27:34 -0400
Subject:
OC High Priority Insp Items Thread-Topic: OC High Priority Insp Items Thread-Index: Ackj4pw6W5wFNqKrTYmGngXch9JedQ==
Message-ID: <2856BC46F6A308418F033D973BBOEE729697628DCF@R1CLSTRO1.nrc.gov>
Accept-Language: en-US Content-Language: en-US X-MS-Has-Attach: yes X-MS-Exchange-Organization-SCL: -1 X-MS-TNEF-Correlator:
<2856BC46F6A308418F033D973BBOEE729697628DCF@R1 CLSTR01. nrc.gov>
MIME-Version: 1.0
Oyster Creek Outage Inspection License Renewal Commitments - IP 71003 Drywell Shell Thickness Verifications 27 Oct - General DNW Access Lower Drywell Shell Internal UT (at Sand Bed Region elevations) 19 Locations inside drywell [IS-328227-004, 3.2.2]
7x7 arrays over a 6"x6" area, and 1x7 arrays, on 1" increments 29 Oct Day Shift, R2096031 [date confirmed by NDE]
Commitment 27, Item (1 & 21)
Lower Drywell Shell External UT (in Sand Bed Bays) 106 UT readings, in the 10 bays (2-shift, 24-hr activities) [IS-328227-004, 3.2.3]
Access through 20" manway (tunnel)
Commitment 27, Item (9,14, & 21)
Bay 1 30 Oct
[critical bay, based on previous inspection]
Bay 3 30 Oct Bay 5 27 Oct Bay 7 29 Oct Bay 9 28 Oct Bay 11 28 Oct
[critical bay, based onpreious inspection]
Bay 13 28 Oct
[critical bay, basedonp*..reious inspeptionl]
Bay 15 29 Oct Bay 17 3 Nov Bay 19 30 Oct Upper Drywell Shell UT at Elev 71' (knuckle region)
Transition from 2.625" plate to 0.640" plate [IS-328227-004, 3.2.8]
4 locations using a dynamic scan of a 6"x6" area 1 Nov 1700, R2096037 Commitment 27, Item (11)
Lower Drywell Shell UT at Elev 23' (bottom to middle spherical plates)
Transition from 0.770" plate to 1.154" plate [IS-328227-004, 3.2.7]
4 locations using a dynamic scan of a 6"x6" area Does NOT appear to be scoped into outage
[29 Oct 0600, C2017059 (one-time inspection of 4 butt welds)]
Commitment 27, Item (10)
Upper Drywell Shell UT at Various Elevations 9 locations using a 7x7 array, at elev. 50', 51', 60', and 87' [IS-328227-004, 3.2.1]
Commitment 27, Item (7)
Drywell Floor Inspection Access Trenches UT & VT in Bay 5 & Bay 17 Trenches [IS-328227-004, 3.2.6]
Remove & reinstall lower 6" of grout at bottom of Bay 5 trench Inspect caulk sealant (trench edge where concrete meets shell)
Verify no water accumulation 29 Oct 2100, R2117387 Commitment 27, Item (5,16, & 20)
Oyster Creek Outage Inspection License Renewal Commitments - IP 71003 Drvwell Shell Leakage Verifications Cavity Strippable Coating prior to flood-up 27 Oct 1500, R2098683 Commitment 27, Item (2)
Rx Cavity Concrete Trough Drain Camera Inspection of Rx cavity trough drain line for blockage only 1 drain line, goes to RW drain on Elev 70' 29 Oct 0300, R2095857 Commitment 27, Item (13)
Rx Cavity Seal Leakage Trough Drains Daily leakage check when cavity is flooded Acceptance criteria < 12 gpm 1 drain line, goes to RW drain on Elev 70' No leakage detection instrumentation R2102695 Commitment 27, Item (3)
Sand Bed Region Drains (5 drain lines)
Daily leakage check R2102695 Commitment 27, Item (3)
Moisture Barrier Seal between Sand Bed Region Concrete and Embedded Drywell Shell Inspect seal at junction between concrete and shell [IS-328227-004, 3.2.4.1.4]
?? Schedule Date' Commitment 27, Item (3, 12, & 21)
Moisture Barrier between Drywell Shell and Concrete Floor Curb inside Drywell Inspect moisture barrier between curb and shell 30 Oct 0600, R2097321 Commitment 27, Item (17)
Oyster Creek Outage Inspection License Renewal Commitments - IP 71003 Drvwell Shell Coating Verifications Drywell Interior Service Level I Coating Inspect shell coating inside drywell 29 Oct 0500, R2096685 Commitment 33, Item (1)
Drywell Exterior Service Level II Coating in Sand Bed Bays VT epoxy coating in each bay (2-shift, 24-hr activities) [IS-328227-004, 3.2.4]
Commitment 27, Item (4 & 21)
Commitment 33 Bay 1 4 Nov Bay 3 28 Oct Bay 5 2
Nov Bay 7 29 Oct Bay 9 28 Oct Bay 11 28 Oct Bay 13 28 Oct Bay 15 29 Oct Bay 17 2 Nov Bay 19 28 Oct Electrical Cable Inspections Feeder Cable to Auxiliary Transformer (Bank 4)
Inaccessible Medium Voltage Cable Perform power factor test of 4 kV transformer feeder cable 30 Oct 1000, R2026131 Commitment 36 Feeder Cable to Startup Transformer (Bank 6)
Inaccessible Medium Voltage Cable Power factor test of 4 kV transformer feeder cable 2 Nov 0600, R2033700 Commitment 36 Feeder Cable to P-37-1 Inaccessible Medium Voltage Cable Hi-Pot feeder cable 29 Oct 0500, R2054006 Commitment 36 Feeder Cable to P-37-5 Inaccessible Medium Voltage Cable Hi-Pot feeder cable
,j??Schedule Date, R2059713 Commitment 36
I,
Oyster Creek Outage Inspection License Renewal Commitments - IP 71003 Cable Inspection in Trunion Room Visually inspect a representative sample of accessible cables and connections located in adverse localized environments, for indications of accelerated insulation aging 26 Oct 0400, R2122597 Commitment 34 Cable Inspection in Drywell Visually inspect a representative sample of accessible cables and connections located in adverse localized environments, for indications of accelerated insulation aging 29 Oct 0500, R2122597 Commitment 34 Non-drywell ISI & NDE Inspections Isolation Condenser One-time Inspection of two stainless steel pipe sections in stagnant or low flow area in the Isolation Condenser System, to verify no stress corrosion cracking.
A21841 19 (AR/Library)
?? Schedule Date, Commitment 24, Item (8)
Isolation Condenser One-time Inspection UT of "B" Isolation Condenser shell below the waterline, to verify no pitting corrosion and confirm effectiveness of Water Chemistry Program.
31 Oct - coatings inspection with UT Commitment 24, Item (2)
Open Cycle Cooling & Buried Pipe Inspections ESW Expansion Joint Periodic inspection 27 Oct 1400, R2081668 Commitment xx ??
ESW Buried Piping Replace previously un-replaced buried ESW piping New pipe already installed, needs to be connected in-place of existing old pipe
??chedul D ate for new piigte-in Commitment 63 ESW Intake Structure Periodic inspection of components submerged in salt water Structures Monitoring Program, inspect ESW/SW piping & components located under the Deck ROV video of piping and coating
?*? Schedule Date (R2120584??)
Commitment 31 Item (7)
Commitment 32 Item (2)