Enclosure 2 - Oconee Nuclear Station Regulatory Audit - Documents Reviewed
ML090900433
Person / Time
Site: Oconee  
Issue date: 04/06/2009
From: Lain P
NRC/NRR/DRA/AFPB
To: Howe A, Klein A
NRC/NRR/DRA/AFPB, NRC/NRR/DRA/APLA
Lain, P NRR/DRA/AFPB 415-2346
Shared Package
ML090900390 List:
References
TAC MD0395, TAC MD0396, TAC MD0397
Download: ML090900433 (2)


Text

Enclosure 2 Documents Reviewed at the Oconee Nuclear Station Regulatory Audit Reference Number Title Revision OSC-9291 NFPA 805 Transition B-2 Table 1

OSC-9293 NFPA 805 Transition Radioactive Release G-1 Table 0

OSC-9295 NFPA 805 Transition B-1 Table/Report 1

OSC-9313 NFPA 805 Transition Non-Power Fire Area Assessments (Pinch Points Analysis) 0 OSC-9314 NFPA 805 Transition Risk-Informed, Performance-Based Change Evaluation Methodology 0

OSC-9315 NFPA 805 Transition Change Evaluation - Fire Area RB1 0

OSC-9316 NFPA 805 Transition Change Evaluation - Fire Area RB2 0

OSC-9317 NFPA 805 Transition Change Evaluation - Fire Area RB3 0

OSC-9318 Oconee NFPA 805 Transition Change Evaluation -

Fire Area WP1 0

OSC-9319 Oconee NFPA 805 Transition Change Evaluation -

Fire Area WP2 0

OSC-9320 Oconee NFPA 805 Transition Change Evaluation -

Fire Area WP3 0

OSC-9321 Oconee NFPA 805 Transition Change Evaluation -

Fire Area BOP 0

OSC-9323 Oconee NFPA 805 Transition Change Evaluation -

Fire Area YARD-W 0

OSC-9324 Oconee NFPA 805 Transition Change Evaluation -

Fire AREA YARD-E 0

OSC-9375 Oconee Fire PRA Scenario Development 0

OSC-9376 Oconee Fire PRA Cable Selection 0

OSC-9377 Oconee Fire PRA Model Development 0

OSC-9378 Oconee Fire PRA Summary 0

OSC-9505 Oconee NFPA 805 Transition Change Evaluation -

Fire Area SSF 0

OSC-9519 Oconee Unit 2 Fire PRA Summary 0

OSC-9622 Oconee Unit 1 Comparative Screening Analysis 0

EIR 51-5044354-003 Oconee Appendix R Fire Safe Shutdown Analysis (Unit 1) 3 OSC-9302 Fire Protection Evaluation for Balance of Plant (BOP)

Fire Area Partiioning 0

OSS-0254-00-00-4008 Design Basis specification for Fire Protection OSC-8978 Oconee Fire PRA Component Selection 2

OSC-8979 Oconee Plant Partitioning and Ignition Frequencies 1

Reference Number Title Revision OSC-9215 Oconee Appendix R Fire Safe Shutdown Analysis (Unit 2 and 3) 1 OSC-9268 NFPA 805 Transition Non-Power Operations Component Selection 0

OSC-9290 NFPA 805 Transistion Licensing Action Review 0

OSC-9292 NFPA 805 Transition B-3 Table/Report 0

OSC-9296 Fire Protection Evaluation for Unit 3 Blockhouse Wall 0

OSC-9297 Fire Protection Evaluation for West Penetration Pipe Tunnel Area to Auxiliary Building 0

OSC-9298 Fire Protection Evaluation for West Penetration Room to Auxiliary Building Purge Inlet Room 0

OSC-9347 Thermal Hydraulic Analysis for NFPA 805 Transition 3

OSC-9376 Oconee Fire PRA Model Development 0

OSC-9518 Oconee Fire PRA Application Calculation 2

OSC-9535 Recovery Action and DID Action Evaluation in Support of Nuclear Safety Capability Assessment 0

OSC-9659 Nuclear Safety Capability Assessment for Units 1,2,3 (draft) 51-5044354-004 Areva Engineering Information Record, Oconee Appendix R Fire Safe Shutdown Analysis (draft) 4 Summary of Control Room Abandonment Times at Oconee Nuclear Power Station Unit 3 (draft)

O-08-04820 PIP Item O-08-02163 PIP Item O-08-02006 PIP Item O-08-02520 PIP Item O-02-03870 PIP Item O-05-04125 PIP Item O-01-03492 PIP Item KFD-109A-1.1 Drawing Flow Diagram of Service Water System OSS-0254-00-00-4008 Design Basis specification for te Fire Protection 20