ML090760635

From kanterella
Jump to navigation Jump to search
EOC 23 Refueling Outage Inservice Inspection Report Fourth Ten-Year Inservice Inspection Interval
ML090760635
Person / Time
Site: Oconee Duke Energy icon.png
Issue date: 03/06/2009
From: Baxter D
Duke Energy Carolinas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
Download: ML090760635 (275)


Text

SDuke Duke DAVE BAXTER Vice President Energy Oconee Nuclear Station Duke Energy ON01 VP / 7800 Rochester Highway Seneca, SC 29672 864-873-4460 March 6, 2009 864-873-4208 fax dabaxter@dukeenergy.com U.S. Nuclear Regulatory Commission Washington, DC 20555 Attention: Document Control Desk

Subject:

Duke Energy Carolinas, LLC Oconee Nuclear Station, Unit 2 Docket No. 50-270 Unit 2 EOC 23 Refueling Outage Inservice Inspection Report Fourth Ten-Year Inservice Inspection Interval Please find attached a copy of the Inservice Inspection Report for Oconee Unit 2 End of Cycle 23 Refueling Outage. This report is submitted pursuant to Section XI of the ASME Boiler and Pressure Vessel Code, 1998 Edition, with 2000 addenda, Subsubarticles IWA 6230 and IWA-6240.

This report does not include activities specific to the Steam Generator Tube Inservice Inspection. An additional summary report which documents the Steam Generator Tube Inservice Inspection of the Unit 2 EOC-23 Refueling Outage will be transmitted separately.

If there are any questions you may contact Corey Gray at (864) 873-6325.

Sincerely, D ye Baxter, Site Vice-President Oconee Nuclear Station Attachment 4 C7 www. duke-energy.com

U. S. Nuclear Regulatory Commission March 6, 2009 Page 2 xc wo/attachment:

Luis Reyes Region II Administrator U.S. Nuclear Regulatory Commission 61 Forsyth Street, S. W., Suite 23T85 Atlanta, GA 30303 John Stang, Projects Manager Office of Nuclear Reactor Regulation U. S. Nuclear Regulatory Commission Washington, D. C. 20555 Andy Hutto NRC Senior Resident Inspector Oconee Nuclear Station

U. S. Nuclear Regulatory Commission March 6, 2009 Page 3 bxc w/attachement:

Document Control ELL EC050 G. L. Brouette (ANII) bxc w/o attachment:

T. J. Coleman L. C. Keith M. A. Pyne R. P. Todd C. A. Gray R. L. Gill Jr A. D. Best ISI File

INSERVICE INSPECTION REPORT DUKE ENERGY CAROLINAS OCONEE NUCLEAR STATION UNIT 2 TWENTY-THIRD REFUELING OUTAGE h Duke aEnergy

Owner's Report For INSERVICE INSPECTIONS OCONEE UNIT 2 2008 REFUELING OUTAGE EOC23 (OUTAGE 3)

Plant Location: 7800 Rochester Highway, Seneca, South Carolina 29672 NRC Docket No. 50-270 Commercial Service Date: September 9, 1974 Document Completion Date z? ,3 109 Owner: Duke Energy Carolinas 526 South Church St.

Charlotte, N. C. 28201-1006 Revision 0 Prepared By: C Date 0_____

Reviewed By: Date

/

Approved By: Date _____

a,

FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules

1. Owner:' Duke Energy Carolinas, 526 S. Church St.. Charlotte, NC 28201-1006 (Name and Address of Owner)
2. Plant: Oconee Nuclear Station, 7800 Rochester Highway, Seneca, SC 29672 (Name and Address of Plant)
3. Plant Unit: 2 4. Owner Certificate of Authorization (if required) N/A
5. Commercial Service Date: September 9, 1974 6. National Board Number for Unit N/A
7. Components Inspected:

Component or Manufacturer Manufacturer State or National Appurtenance Installer Installer Serial Province No. ,Board No.

No.'

See Section 1.1 in the Attached Report Note: Supplemental sheets in the form of lists, sketches, or drawings may be used provided (1) size is 81/2 in. x 11 in., (2) information in items 1 through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.

Total number of pages contained in this report 271

FORM NIS-1 (Back)

8. Examination Dates May 30, 2007 to December 12, 2008
9. Inspection Period Identification: Second Period
10. Inspection Interval Identification: Fourth Interval
11. Applicable Edition of Section XI 1998 Addenda 2000
12. Date/Revision of Inspection Plan: January 26, 2008 / Revision 1
13. Abstract of Examinations and Tests. Include a list of examinations and tests and a statement concerning status of work required for the Inspection Plan. See Sections 2.0, 3.0 and 6.0
14. Abstract of Results of Examination and Tests. See Sections 4.0 and 6.0
15. Abstract of Corrective Measures. See Subsection 4.3 We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.

Certificate of Authorization No. (if applicable) NA Expiration Date NA' Date Z _ Iq_-09 Signed Duke Energy By Carolinas.

Owner CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of AAergv Lea w employed by Hartford Steam Boiler of Connecticut (HSBCT) have inspected the components described in this Owner's Report during the period 5- .3o - o 7 to /2 -/Z -6> , and state that to the best of my knowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in the Owner's Report in accordance with the Inspection Plan and as required by the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, test, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection

______________________Commissions A/'/,, 5 -

Inspector's Signature National Board, State, Province, and Endorsements Date /Z_/n ?

HSBCT 200 Ashford Center North Suite 205 Atlanta, GA. 30338-4860 (800) 417-3721 I www.hsbct.com

DISTRIBUTION LIST

1. Duke Energy Carolinas Nuclear Technical Services Division Section XI Inspection Program Section
2. NRC Document Control Desk
3. HSBCT (AIA)

C/o ANII at Oconee Note: The following personnel are to be notified via e-mail after the Inservice Inspection Report has been stored in the Nuclear Electronic Document Library:

GO Nuclear Assurance c/o Bruce Nardoci.

Inspection and Welding Services (ISI Coordinator)

TABLE OF CONTENTS Section Title Revision 1.0 General Information 0 2.0 Fourth Ten Year Inspection Status 0 3.0 Final Inservice Inspection Plan 0 4.0 Results of Inspections Performed 0 5.0 Owners Report for Repair/Replacement Activities 0 6.0 Pressure Testing 0

1.0 GeneralInformation This report describes the Inservice Inspection of Duke's Oconee Nuclear Station, Unit 2, during Outage 3/EOC 23. This is the first outage in the second inspection period of the Fourth Ten-Year Interval. ASME Section XI, 1998 Edition with the 2000 Addenda, was the governing Code for selection and performing of the ISI examinations.

Included in this report are: the inspection status for each examination category, the final inservice inspection plan, the inspection results for each item examined, and corrective actions taken when reportable conditions were found. In addition, there is an Owner's Report for Repair/Replacement Section included for completed NIS-2 documentation of repairs and replacements.

1.1 Identification Numbers Manufacturer Item Manufacturer or Installer State or National or Installer Serial No. Province No. Board No.

Reactor Vessel Babcock & Wilcox 620-0004-51-52 N/A N-1 05 Reactor Vessel Babcock & Wilcox, 068S-02 N/A 209 Head (replaced head)

Steam Generator A Babcock & Wilcox 006K03 N/A 207 '

Steam Generator B Babcock & Wilcox 006K04 N/A 208 Pressurizer Babcock & Wilcox 620-0004-59 N/A N-1 06 Main Steam Duke Power NA NA NA System Auxiliary Steam Duke Power NA NA NA System Feedwater System Duke Power NA NA NA Emergency Duke Power NA NA NA Feedwater System Steam Generator Duke Power NA NA NA Flush System Condensate Duke Power NA NA NA System EOC 23 Refueling Outage Report Page 1 of 4 Oconee Unit 2 Revision 0 Section 1 February 11, 2009

Manufacturer Item Manufacturer or Installer State or National or Installer Serial No. Province No. Board No.

Vents and Exhaust Duke Power NA NA NA System Condenser Duke Power NA NA NA Circulating Water High Pressure Duke Power NA NA NA Service Water System Low Pressure Duke Power NA NA NA Service Water System Reactor Coolant Duke Power NA NA NA System High Pressure Duke Power NA NA NA Injection System Low Pressure Duke Power NA NA NA Injection System Reactor Building Duke Power NA NA NA Spray System Component Duke Power NA NA NA Cooling System Spent Fuel Cooling Duke Power NA NA NA System Vents - Reactor Duke Power NA NA NA Building Components Drains - Reactor Duke Power NA NA NA Building Components EOC 23 Refueling Outage Report Page 2 of 4 Oconee Unit 2 Revision 0 Section 1 February 11, 2009

1.2 Personnel,Equipment and MaterialCertifications All personnel who performed or evaluated the results of inservice inspections during the time frame bracketed by the examination dates shown on the NIS-1 Form were certified in accordance with the requirements of 1998 Edition of ASME Section XI with the 2000 addenda including Appendix VII for ultrasonic inspections. In addition, ultrasonic examiners were qualified in accordance with ASME Section XI, Appendix VIII, and 1998 Edition with the 2000 Addenda through the Performance Demonstration Initiative (PDI) for Supplements 2, 3, 4, 6, 8, 10 and 11. Preservice examinations of weld overlays were conducted in accordance with Code Case N-504-2 including non-mandatory Appendix Q.

The appropriate certification records for each inspector, calibration records for inspection equipment, and records of materials used (i.e., NDE consumables) are on file at Oconee Nuclear Station or copies can be obtained by contacting Duke's Corporate Office in Charlotte, North Carolina.

The copies of the certification records for Washington Group International inspectors and Atlantic Group inspectors can be obtained by contacting Duke's Corporate Office in Charlotte, North Carolina.

1.3 Reference Documents The following reference documents apply to the inservice inspections performed during this report period. A copy may be obtained by contacting the ISI Plan Manager at Duke's Corporate Office in Charlotte, North Carolina.

Code Case N-460- Applicable to items in this report where less than 100%

coverage of the required weld examination volume was achieved. These items are identified on the Run D that is located in Section 4 of this report.

Code Case N-700- Alternate Rules for selection of Classes 1, 2 and 3 Vessel Welded Attachments for Examination Section XI, Division 1. (Categories B-K, C-C, and D-A).

Code Case N-706- Alternate Examination Requirements of Table IWB-2500-1 and Table IWC-2500-1 for PWR Stainless steel Residual and Regenerative Heat Exchangers (Category C-A at Oconee).

Code Case N-504 Applicable to items that weld overlay was performed on.

During 2EOC-23 outage there were welds that had weld overlay performed on them and the PSI exams were performed per Code Case N-504-2.

Code Case N-665- Alternative requirements for beam angle measurements using refracted longitudinal wave search units.

EOC 23 Refueling Outage Report Page 3 of 4 Oconee Unit 2 Revision 0 Section 1 February 11, 2009

Duke Power Company Problem Investigation Process Report 0-09-00822. This PIP was written to track the evaluation process and resolution for limited coverage on UT examinations of welds that were inspected during EOC-23 for Unit 2. This will include processing relief request if it is determined that greater than ninety percent of coverage cannot be achieved. The welds with limited coverage are listed in Section 4.4 of this report.

Duke Power Company Problem Investigation Process Report 0-08-06882 was written to document leakage detected during an augmented VT-2 bare metal visual examination of the reactor vessel head (summary number 02.G11.1.0002).

PIP 0-09-00530 was written to document the work orders that had work completed during this report period but the documentation was not completed in time for the NIS-2 forms to be incorporated into this report.

Request for Relief 07-ON-001 (Allows Duke an alternative to perform examinations of weld overlays per Code Case N-504-2.)

Request for Relief 03-006 (Allows Duke an Alternative for the Snubber Examinations required in IWF-5000 for the 4th interval.)

1.4 Augmented and Elective Examinations Augmented and elective examination information found within. this Inservice Inspection Report is not required by the ASME Section XI Code; therefore, it is exempt from ANII review, verification, and/or record certification.

1.5 Responsible Inspection Agency Hartford Steam Boiler of Connecticut (HSBCT) is responsible for the third party inspections required by ASME Section XI.

Authorized Nuclear Inservice Inspector(s)

Name: Gary Brouette and Nancy Slaughter Employer: HSBCT Business Address: 200 Ashford Center North Suite 205 Atlanta, GA 30338-4860 (800) 417-3721 www.hsbct.com EOC 23 Refueling Outage Report' Page 4 of 4 Oconee Unit 2 Revision 0 Section 1 February 11, 2009

2.0 Fourth Ten Year Interval Inspection Status The completion status of inspections required by the 1998 ASME Code Section XI, with the 2000 Addenda, is summarized in this section. The requirements are listed by the ASME Section XI Examination Category as defined in Table IWB-2500-1 for Class 1 Inspections, Table IWC-2500-1 for Class 2 Inspections, and IWF-2500-1 for Class 1 and 2 Component Supports. Augmented inspections are also included.

Class 1 Inspections Examination Inspections Inspections Percentage *Deferral Category Description Required Completed Completed Allowed B-A Pressure Retaining Welds 6 Welds .5 Weld 8% Yes in Reactor Vessel B-B Pressure Retaining Welds 10 Welds 4 Welds 40% No in Vessels Other than Reactor Vessel B-D Full Penetration Welds of 54 20 37% Partial Nozzles in Vessels Inspections Inspections Inspection Program B B-F Pressure Retaining 2 Welds 0 Welds 0% Yes Dissimilar Metal Welds B-G-1 Pressure Retaining Bolting 128 Items 81.66 Items 64% Yes Greater than 2 Inches in Diameter B-G-2 Pressure Retaining Bolting 20 Items 12 Items 60% No' 2 Inches and Less in Diameter B-J Pressure Retaining Welds 160 Welds 65.5 Welds 41% No in Piping B-K Welded Attachments for 11 6 55% No Vessels, Piping, Pumps 1and Valves Deferral of inspection to the end of the interval as allowed by ASME Section XI Tables IWB and IWC 2500-1.

EOC 23 Refueling Outage Report Page 1 of 4 Oconee Unit 2 Revision 0 Section 2 February 11, 2009

Class 1 Inspections (Continued)

Examination Inspections Inspections Percentage

  • Deferral Category Description Required Completed Completed Allowed B-L-1 Pressure Retaining Welds 1 Weld 1 Weld 100% Yes in Pump Casings B-L-2 Pump Casings 1 Casing 0 Casing 0% Yes B-M-1 Pressure Retaining 1 Valve Body 0 Valve Body 0% Yes Welds in Valve Bodies Weld Weld B-M-2 Valve Bodies 3 Valves 1 Valves 33% Yes B-N-1 Interior of Reactor Vessel 3 Inspections 2 Inspection 67% No B-N-2 Welded Core Support 1 Inspection 0 Inspections 0% Yes Structures and Interior Attachments to Reactor Vessels B-N-3 RemovableCore Support 1 Inspection 0 Inspections 0% Yes Structures III B-0 Pressure Retaining.Welds 12 Housing 8 Housing 67% Yes in Control Rod Housings Welds Welds B-P All Pressure Retaining Components REFERENCE SECTION 6.0 OF THIS REPORT B-Q Steam Generator Tubing N/A N/A N/A N/A F-A Class 1 Component 37 Supports 20 Supports 54% No F1.10 & F1.040 Supports (Except items. Snubbers)

F-A Class 1 Component **

F1.050 items Supports, Snubbers

  • A Deferral of inspection to the end of the interval as allowed by ASME Section XI Tables IWB and IWC 2500-1.

Inspected under Selected License Commitment 16.9.18 per Relief Request 03-006 EOC 23 Refueling Outage Report Page 2 of 4 Oconee Unit 2 Revision 0 Section 2 February 11, 2009

Class 2 Inspections Examination Inspections, Inspections Percentage *Deferral Category Description Required Completed Completed Allowed C-A Pressure Retaining Welds 11 Welds 7 Welds 64% No in Pressure Vessels C-B Pressure Retaining Nozzle 4 Welds 3 Welds 75% No Welds in Vessels C-C Integral Attachments for 38 21 55% No Vessels, Piping, Pumps Attachments Attachments and Valves C-D Pressure Retaining Bolting 2 Items 1 Items 50% No Greater Than 2 Inches in Diameter C-F-1 Pressure Retaining Welds 164 Welds 70 Welds 43% No in Austenitic Stainless Steel or High Alloy Piping C-F-2 Pressure Retaining Welds 66 Welds 32 Welds 48% No in Carbon or Low Alloy Steel Piping C-G Pressure Retaining Welds N/A N/A N/A N/A in Pumps and Valves C-H All Pressure Retaining Components REFERENCE SECTION 6.0 OF THIS REPORT F-A Class 2 Component 137 Supports 69 Supports 50% No F1.020 & F1.040 Supports (Except items. Snubbers)

F-A Class 2 Component **

F1.050 items Supports, Snubbers Deferral of inspection to the end of the interval as allowed by ASME Section Xl Tables IWB3 and,IWC 2500-1.

  • Inspected under Selected License Commitment 16.9.18 per Relief Request 03-006 EOC 23 Refueling Outage Report Page 3 of 4 Oconee Unit 2 Revision 0 Section 2 February 11,2009

Augmented/Elective Inspections Augmented and elective examination information found within this Inservice Inspection Report is not required by the ASME Section XI Code; therefore, it is exempt from ANII review, verification, and/or record certification.

Summary Number Description Percentage Complete 02.G1.1. Reactor Coolant Pump Flywheel 100% of EOC 23 Requirements 02.G2.1. HPI Nozzle Safe End Examinations None scheduled for EOC 23 02.G3.1. Pressurizer Surge Line Examinations None scheduled for EOC 23 02.G4.1. Thermal Stress Piping (NRC Bulletin 88-08) None scheduled for EOC 23 02.G1 1.1.0001 Reactor Pressure Vessel Head Penetration Nozzle by None scheduled for EOC 23 UT Examination per NRC Order EA-03-009.

O2.G1 1.1.0002 Bare Metal Visual Examination of the Reactor Pressure 100% of EOC 23 Requirements Vessel Head Surface per NRC Order EA-03-009.

02.G12.1. UT Examination per MRP-139 None scheduled for EOC 23 02.G12.2. UT Examination per MRP-139 None scheduled for EOC 23 02.G12.3. UT Examination per MRP-139 None scheduled for EOC 23 02.G13.1. VT-2 Examination per MRP-139 100% of EOC 23 Requirements 02.G13.2. VT-2 Examination per MRP-139 None scheduled for EOC 23 02.G13.3. VT-2 Examination per MRP-139 100% of EOC 23 Requirements 02.G13.4. VT-2 Examination per MRP-139 100% of EOC 23 Requirements 02.G14.1. VT-2 Examination per Oconee Response to BL-2004-01 100% of EOC 23 Requirements 02.H1.1. Pressurizer Sensing/ Sampling Nozzle Safe Ends None scheduled for EOC 23 02.H2.1. Class 1 RTE Mounting Bosses 100% of EOC 23 Requirements 02.H3.1. Main Feedwater Piping in the East and West 100% of EOC 23 Requirements Penetration Rooms per QA-513J (ER-ONS-04-03) 02.H4.1. Main Feedwater and Main Steam Piping Supports and 100% of EOC 23 Requirements Attachment Welds per QA-513J (ER-ONS-04-05)

EOC 23 Refueling Outage Report Page 4 of 4 Oconee Unit 2 Revision 0 Section 2 February 11, 2009

  • 3.0 FinalInservice Inspection Plan The final Inservice Inspection Plan shown in this section lists all ASME Section Xl Class 1, Class 2, Class 3, and Augmented examinations credited for this report period.

The information shown below is a field description for the reporting format included in this section of the report:

Summary/Item = ASME Section XI Tables IWB-2500-1 Number (Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2 ), Augmented Requirements ID Number = Unique Identification Number Sys = Component System Identification Iso / Dwg. Numbers = Location and/or Detail Drawings Proc = Examination Procedures Insp Req. - Examination Technique - Magnetic Particle, Dye Penetrant, etc.

Mat / Sch. = General Description of Material Diam. / Thick = Diameter/Thickness Cal Blocks = Calibration Block Number Comments = General and/or Detail Description EOC 23 Refueling Outage Report Page 1 of 1 Oconee Unit 2 Revision 0 Section 3 February 11, 2009

DUKE EMiRGY NUCLEAR TECHAVAL SERVICES ScheduleWorks Inservice Inspection DatabaseManagementSystem Plan Report Oconee 2, 4th Interval, Outage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched ThicklDia Cal Blocks Comments / HistoricalData Categor AUG 02.G1 .1.0006 GO1.001.003, 2GO1.001.003A 2-RCP-2B1 50 OM-201D-038 54-ISI-117 UT CS 9.500 / 72.000 RCP 2B1 Flywheel. Reference Section 7 of the Class 1 O-ISIN4-100A-2.1 ISI Plan, General Requirements. --

(GO1.001.003A) Whenever maintenance or repair activities necessitate flywheel removal, a surface examination of exposed surfaces and a complete volumetric examination shall be performed if the interval measured from the previous such inspection is greater than 6 2/3 years.

02.G1.1.0006 GOl .001.003, GOl .001 .003A 2-RCP-2B1 50 OM-2011D-038 54-ISI-271 MT CS 9.500 / 72.000 RCP 2131 Flywheel. Reference Section 7 of the Class 1 O-ISIN4-100A-2.1 ISI Plan, General Requirements. --

(GOl .001 .003A) Whenever maintenance or repair activities necessitate flywheel removal, a surface examination of exposed surfaces and a complete volumetric examination shall be performed if the interval measured from the previous such inspection is greater than 6 2/3 years.

02.G1 1.1.0002 G1l1.001.002 2-RPV-HEAD-PEN 50 OM-201-2271 NDE-68 VT-2 CS-Inconel 0.000 / 0.000 NRC Order EA-03-009 requires bare metal Class 1 O-ISlN4-100A-2.1 visual examination of 100% of the Reactor Pressure Vessel Head surface (including 360 degrees around each RPV head penetration nozzle). For additional information, contact J.M. Shuping of the Metallurgy, Lab Services Group.

Procedure MPIO/AI1 150/029-001 Procedure NDE-68 in conjunction with MP/O/A/1 150/029-001 should be used to perform the Bare Metal Visual Inspection.

These items are being removed from the schedule and made inactive because they will now be examined per Code Case N-729-1 requirements. See Plan Addenda ONS-033 and ONS2-076 Dissimilar Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 1 of 71

Oconee 2, 4th Intervetage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor AUG 02.G13.1.0011 G13.001.011 2-PZR-WP63-1 50 ISI-OCN2-002 NDE-68 VT-2 CS-Inconel 1.18. 5/1.000 The surface of the Pressurizer Sensing and Circumferential Class 1 B&W149771E Sampling Nozzle-to-Safe End Welds shall be examined (W-X Quadrant). Augmented Inspection Per MRP-1 39. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Inspect with item number G13.001.012.

Dissimilar Nozzle Pc.30 to Safe End Pc.42 02.G13.1.0012 G13.001.012 2RC-240-6B 50 2RC-240 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 Augmented Inspection Per MRP-139. Contact Circumferential Class 1 Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe toSafe End 02.G13.1.0013 G13.001.013 2-PZR-WP63-2 50 ISI-OCN2-002 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 The surface of the Pressurizer Sensing and Circumferential Class 1 B&W149771E Sampling Nozzle-to-Safe End Welds shall be examined (Y-Z Quadrant). Augmented Inspection Per MRP-1 39. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Inspect with item number G1 3.001.014.

Dissimilar Nozzle Pc.30 to Safe End Pc.42 Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 2 of 71

0 Oconee 2, 4th Interv*

Insp tage 3 (EOC-23)

Summary Num Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor AUG 02.G1 3.1.0014 G13.001.014 2RC-240-9A 50 2RC-240 NDE-68 VT-2 CS-Inconel 1.185 /1.000 Augmented Inspection Per MRP-139. Contact Circumferential Class 1 Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End 02.G1 3.1.0015 G13.001.015 2-PZR-WP63-3 50 ISI-OCN2-002 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 The surface of the Pressurizer Sensing and Circumferential Class 1 B&W149771E Sampling Nozzle-to-Safe End Welds shall be examined (Z-W Quadrant). Augmented Inspection Per MRP-1 39. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Inspect with item number G1 3.001.016.

Dissimilar Nozzle Pc.30 to Safe End Pc.42 02.G13.1.0016 G13.001.016 2RC-240-4A 50 2RC-240 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 Augmented Inspection Per MRP-1 39. Contact Circumferential Class 1 Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End Printed 02/16/091ck8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 3 of 71

Oconee 2, 4th Interv*tage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor AUG 02.G13.1.0017 G13.001.017 2-PZR-WP63-4 50 IS1-OCN2-002 NDE-68 VT-2 CS-Inconel 1.185 /1.000 The surface of the Pressurizer Sensing and Circumferential Class 1 B&W149771E Sampling Nozzle-to-Safe End Welds shall be examined (W-X Quadrant). Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Inspect with item number G13.001.018.

Dissimilar Nozzle Pc.30 to Safe End Pc.42 02.G133.1.0018 G13.001.018 2RC-240-25V 50 2RC-240 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 Augmented Inspection Per MRP-1 39. Contact Circumferential Class 1 Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End 02.G13.1.0019 G13.001.019 2-PZR-WP63-5 50 ISI-OCN2-002 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 The surface of the Pressurizer Sensing and Circumferential Class 1 B&W149771E Sampling Nozzle-to-Safe End Welds shall be examined (Y-Z Quadrant). Augmented Inspection Per MRP-1 39. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Inspect with item number G1 3.001.020.

Dissimilar Nozzle Pc.30 to Safe End Pc.42 Printed 02/16/091ck8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 4 of 71

Summary Num Oconee 2, 4th Intervetage 3 (EOC-23)

Insp Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData S0 Component ID / Type System ISO/DWG Number Cateaor AUG 02.G13.1.0020 G13.001.020 2RC-240-1A 50 2RC-240 NDE-68 VT-2 CS-Inconel 1.185 /1.000 Augmented Inspection Per MRP-139. Contact Circumferential Ch ass 1 Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End 02.G13.1.0021 Gi13.001.021 2-PZR-WP63-6 50 ISI-OCN2-002 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 The surface of the Pressurizer Sensing and Circumferential Class 1 B&W149771E Sampling Nozzle-to-Safe End Welds shall be examined (Z-W Quadrant). Augmented Inspection Per MRP-1 39. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Inspect with item number G1 3.001.022.

Dissimilar Nozzle Pc.30 to Safe End Pc.42 02.G13.1.0022 G13.001.022 2RC-240-21 V 50 2RC-240 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 Augmented Inspection Per MRP-139. Contact Circumferential Cla ss 1 Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End Printed 02116/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 5 of 71

0 Summary Num Oconee 2, 4th Intervstage Insp 3 (EOC-23)

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor AUG 02.G13.1.0023 G13.001.023 2-PZR-WP63-7 50 ISI-OCN2-002 NDE-68 VT-2 CS-Inconel 1.185 /1.000 surface of the Pressurizer Sensing and Circumferential Class 1 B&W149771E pling Nozzle-to-Safe End Welds shall be nined (Z-W Quadrant). Augmented ection Per MRP-1 39. Contact Jody ping for additional information on this nination.

Metal Visual Examinations are to be irmed each refueling outage by a VT-2 fied inspector. Acceptance criteria is "no ence of borated water leakage."

ect with item number G13.001.024.

Dissimilar Nozzle Pc.30 to Safe End Pc.42 02.G13.1.0024 G13.001.024 2RC-206-6 50 2RC-206 NDE-68 VT-2 SS-Inconel 1.250 / 1.000 Augmented Inspection Per MRP-1 39. Contact Circumferential Class 1 Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End 02.G13.1.0026 G13.001.026 2RC-278-66 50 2RC-278 NDE-68 VT-2 CS-Inconel 0.250 / 1.000 1 inch HL SB-166 Pressure Tap SE to CS Circumferential Class 1 Nozzle, weld and SS pipe weld. (Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)

Augmented Inspection Per MRP-1139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 6 of 71

Oconee 2, 4th Interv* tage 3 (EOC-23)

Summary Num "nsp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments /Historical Data Categor AUG 02.G13.1.0027 G13.001.027 2RC-278-70V 50 2RC-278 NDE-68 VT-2 CS-Inconel 0.250 / 1.000 1 inch HL SB-166 Pressure Tap SE to CS Circumferential Class 1 Nozzle weld and SS pipe weld. (Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)

Augmented Inspection Per MRP-1139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End 02.G13.1.0028 G13.001.028 2RC-277-50 50 2RC-277 NDE-68 VT-2 CS-Inconel 0.250 / 1.000 1 inch HL SB-166 Pressure Tap SE to CS Circumferential Class 1 Nozzle weld and SS pipe weld. (Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)

Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End Printed 02/16/09 lck8302 v. 01 /19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 7 of 71

Summary Num Oconee 2, 4th Interv*tage3 (EOC-23)

Insp 0

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments /Historical Data Categor AUG 02.G13.1.0029 G13.001.029 2RC-277-71V 50 2RC-277 NDE-68 VT-2 CS-Inconel 0.250 / 1.000 1 inch HL SB-166 Pressure Tap SE to CS Circumferential Class 1 Nozzle weld and SS pipe weld. (Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)

Augmented Inspection Per MRP-1 39. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End 02.G13.1.0030 G13.001.030 2RC-278-23 50 2RC-278 NDE-68 VT-2 CS-Inconel 0.250 / 1.000 .075 inch ID HL SB-167 Flowmeter Nozzle SE Circumferential Clas ,s 1 to CS Nozzle weld and SS pipe weld. (Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)

Augmented Inspection Per MRP-1 39. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 8 of 71

0 Summary Num Oconee 2, 4th Interv"tage Insp 3 (EOC-23)

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched ThicWlDia Cal Blocks Comments /Historical Data Cateoor AUG 02.G13.1.0031 G13.001.031 2RC-278-69 50 2RC-278 NDE-68 VT-2 CS-Inconel 0.250 / 1.000 .75 inch ID HL SB-167 Flowmeter Nozzle SE to Circumferential Class 1 CS Nozzle weld and SS pipe weld. (Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)

Augmented Inspection Per MRP-1 39. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End 02.G1 3.1.0032 G13.001.032 2RC-277-24 50 2RC-277 NDE-68 VT-2 CS-lnconel 0.250 / 1.000 .75 inch ID HL SB-167 Flowmeter Nozzle SE to Circumferential Class 1 CS Nozzle weld and SS pipe weld. (Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)

Augmented Inspection Per MRP-139. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End Printed 02/16/09ick8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 9 of 71

Summary Num Oconee 2, 4th Intervlitage3 (EOC-23)

Insp S

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor AUG 02.G13.1.0033 G13.001.033 2RC-277-70 50 2RC-277 NDE-68 VT-2 CS-Inconel 0.250 / 1.000 .75 inch ID HL SB-167 Flowmeter Nozzle SE to Circumferential Class 1 CS Nozzle weld and SS pipe weld. (Examine the Nozzle to Safe-End weld and the Safe-End to Pipe weld.)

Augmented Inspection Per MRP-1 39. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End 02.G13.1.0034 2RC-325-8A 50 2RC-325 NDE-68 VT-2 SS-Inconel 0.250 / 1.000 1 inch PZR vent nozzle SB-166 Nozzle to SS Class 1 pipe weld. (Examine the PZR surface where the PZR Vent Nozzle and the PZR Head/Shell interface and also examine the Nozzle to SS Pipe weld.)

Augmented Inspection Per MRP-1 39. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

This weld was examined in EOC-22 using summary number 02.G13.1.0025.

This weld was listed previously as 2-50-16-8A until it was transferred to iso 2RC-325 After this weld was transferred to iso 2RC-325, it will be examined using summary number 02.G13.1.0034.

Dissimilar Pipe to Safe End Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 10 of 71

Oconee 2, 4th IntervlStage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Cate panAUG 02.G13.3.0001 2SGA-HL-CON-36 50 OM-1201-0103.001 NDE-68 VT-2 CS-Inconel Steam Generator A Hot Leg Connection # 36 Class 1 O-ISIN4-100A-2.1 on drawing OM 1201-0103.001 and Mark # 10 OM-1201-1472.001 on drawing OM-1201-1472.001 Abandoned RTE Thermal Well Connection Augmented Inspection per Corrective Action #

6 in PIP 0-06-2050. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar RTE Hot Leg Thermal Well 02.G13.3.0002 2SGB-HL-CON-27 50 OM-1201-0103.001 NDE-68 VT-2 CS-Inconel Steam Generator B Hot Leg Connection # 27 Class 1 0-ISIN4-100A-2.1 on drawing OM 1201-0103.001 and Mark# 10

<OM-1201-1472.001 on drawing OM-1201-1472.001 Abandoned RTE Thermal Well Connection Augmented Inspection per Corrective Action #

6 in PIP 0-06-2050. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar RTE Hot Leg Thermal Well 02.G13.4.0001 2SGA-2A1-SUCT-CON-11 50 OM-1201-0103.001 NDE-68 VT-2 CS-Inconel Pump 2A1 Suction Piping/ Connection # 11 on Class 1 O-ISIN4-100A-2.1 drawing OM 1201-0103.001 and Mark # 11 on OM-1201-1472.001 drawing OM-1201-1472.001 Abandoned RTE Thermal Well Connection Augmented Inspection per Corrective Action #

6 in PIP 0-06-2050. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pump 2A1 Suction Piping/RTE Thermal Well Printed 02/16/091ck8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 11 of 71

Summary Num Oconee 2, 4th Interv*tage 3 (EOC-23)

"Isp 0

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Cate-gor AUG 02.G13.4.0002 2SGA-2A2-SUCT-CON-14 50 OM-1201-0103.001 NDE-68 VT-2 CS-Inconel Pump 2A2 Suction Piping/ Connection # 14 on Class 1 0-ISIN4-100A-2.1 drawing OM 1201-0103.001 and Mark# 11 on OM-1201-1472.001 drawing OM-1201-1472.001 Abandoned RTE Thermal Well Connection Augmented Inspection per Corrective Action #

6 in PIP 0-06-2050. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pump 2A2 Suction Piping/RTE Thermal Well 02.G133.4.0003 2SGB-2B1-SUCT-CON-3 50 OM-1201-0103.001 NDE-68 VT-2 CS-Inconel Pump 2B1 Suction Piping/ Connection # 3 on Class 1 0-ISIN4-100A-2.1 drawing OM 1201-0103.001 and Mark # 11 on OM-1201-1472.001 drawing OM-1201-1472.001 Abandoned RTE Thermal Well Connection Augmented Inspection per Corrective Action #

6 in PIP 0-06-2050. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pump 2B1 Suction Piping/RTE Thermal Well Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 12 of 71

0 Summary Num Oconee 2, 4th lntervltage 3 (EOC-23)

Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments /Historical Data Cateaor AUG 02.G13.4.0004 2SGB-2B2-SUCT-CON-7 50 OM-1201-0103.001 NDE-68 VT-2 CS-Inconel Pump 2B2 Suction Piping/ Connection # 7 on Class 1 0-ISIN4-100A-2.1 drawing OM 1201-0103.001 and Mark # 11 on OM-1201-1472.001 drawing OM-1201-1472.001 Abandoned RTE Thermal Well Connection Augmented Inspection per Corrective Action #

6 in PIP 0-06-2050. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed every third refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pump 2B2 Suction Piping/RTE Thermal Well 02.G14.1.0001 G14.001.001 2-PZR-THERM 50 NDE-68 VT-2 CS-Inconel 0.250 / 1.000 1.5 inch Thermowell located on the Pressurizer.

Circumferential Class 1 OM 1201-1135 Augmented Inspection Per Oconee Response OM 100-1189 to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Nozzle to Elbow 02.G14.1.0008 G14.001.008 2-PZR-WP63-1 50 ISI-OCN2-002 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 The surface of the Pressurizer Sensingand Circumferential Class 1 B&W149771E Sampling Nozzle-to-Safe End Welds shall be examined (W-X Quadrant). Augmented Inspection Per Oconee response to BL-2004-

01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Inspect with item number G14.001.009.

Dissimilar Nozzle Pc.30 to Safe End Pc.42 Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 13 of 71

0 Summary Num Oconee 2, 4th IntervStage 3 (EOC-23)

Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Cateaor AUG 02.G14.11.0009 G14.001.009 2RC-240-6B 50 2RC-240 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 Augmented Inspection Per Oconee response Circumferential 'lass 1 to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End 02.G14.1.0010 G14.001.010 2-PZR-WP63-2 50 ISI-OCN2-002 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 The surface of the Pressurizer Sensing and Circumferential Class 1 B&W149771E Sampling Nozzle-to-Safe End Welds shall be examined (Y-Z Quadrant). Augmented Inspection Per Oconee response to BL-2004-

01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Inspect with item number G1 4.001.011.

Dissimilar Nozzle Pc.30 to Safe End Pc.42 02.G14.1 .0011 G14.001.011 2RC-240-9A 50 2RC-240 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 Augmented Inspection Per Oconee response Circumferential Class 1 to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 14 of 71

Oconee 2, 4th lntervtage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Cateaor AUG 02.G14.1.0012 G14.001.012 2-PZR-WP63-3 50 ISI-OCN2-002 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 The surface of the Pressurizer Sensing and Circumferential Class 1 B&W149771E Sampling Nozzle-to-Safe End Welds shall be examined (Z-W Quadrant). Augmented Inspection Per Oconee response to BL-2004-

01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Inspect with item number G1 4.001.013.

Dissimilar Nozzle Pc.30 to Safe End Pc.42 02.G14.1.0013 G14.001.013 2RC-240-4A 50 2RC-240 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 Augmented Inspection Per Oconee response Circumferential Class 1 to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar

______________Pipe to Safe End 02.G14.1.0014 G14.001.014 2-PZR-WP63-4 50 ISI-OCN2-002 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 The surface of the Pressurizer Sensing and Circumferential Class 1 B&W149771E Sampling Nozzle-to-Safe End Welds shall be examined (W-X Quadrant). Augmented Inspection Per Oconee response to BL-2004-

01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Inspect with item number G1 4.001.015.

Dissimilar Nozzle Pc.30 to Safe End Pc.42 Printed 02/16109 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 15 of 71

0 Summary Num Oconee 2, 4th lnterv@tage 3 (EOC-23)

Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor AUG 02.G14.1.0015 G14.001.015 2RC-240-25V 50 2RC-240 NDE-68 VT-2 CS-Inconel 1.185 /1.000 Augmented Inspection Per Oconee response Circumferential Class 1 to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End 02.G14.1.0016 G14.001.016 2-PZR-WP63-5 50 ISI-OCN2-002 NDE-68 VT-2 CS-lnconel 1.185 / 1.000 The surface of the Pressurizer Sensing and Circumferential Class 1 B&W149771E Sampling Nozzle-to-Safe End Welds shall be examined (Y-Z Quadrant). Augmented Inspection Per Oconee response to BL-2004-

01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Inspect with item number G1 4.001.017.

Dissimilar Nozzle Pc.30 to Safe End Pc.42 02.G14.1.0017 G14.001.017 2RC-240-1A 50 2RC-240 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 Augmented Inspection Per Oconee response Circumferential Class 1 to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End Printed 02/16/09 Ick8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 16 of 71

0 Summary Num Oconee 2, 4th Intervotage3 (EOC-23)

Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Catepor AUG 02.G14.1.0018 G14.001.018 2-PZR-WP63-6 50 ISI-OCN2-002 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 The surface of the Pressurizer Sensing and Circumferential Class 1 B&W149771E Sampling Nozzle-to-Safe End Welds shall be examined (Z-W Quadrant). Augmented Inspection Per Oconee response to BL-2004-

01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Inspect with item number G14.001.019.

Dissimilar Nozzle Pc.30.to Safe-End Pc.42-02.G14.1.0019 G14.001.019 2RC-240-21V 50 2RC-240 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 Augmented Inspection Per Oconee response Circumferential Class 1 to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End 02.G14.1 .0020 G14.001.020 2-PZR-WP63-7 50 ISI-OCN2-002 NDE-68 VT-2 CS-Inconel 1.185 / 1.000 The surface of the Pressurizer Sensing and Circumferential Class1 B&W149771E Sampling Nozzle-to-Safe End Welds shall be examined (Z-W Quadrant). Augmented Inspection Per Oconee response to BL-2004-

01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Inspect with item number G14.001.021.

Dissimilar Nozzle Pc.30 to Safe End Pc.42 Printed 02/16/091ck8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 17 of 71

0 Summary Num Oconee 2, 4th Intervl Insp tage 3 (EOC-23)

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor AUG 02.G14.1.0021 G14.001.021 2RC-206-6 50 2RC-206 NDE-68 VT-2 SS-lnconel 1.250 / 1.000 Augmented Inspection Per Oconee response Circumferential 'lass 1 to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

Dissimilar Pipe to Safe End 02.G14.1.0023 2RC-325-8A 50 2RC-325 NDE-68 VT-2 SS-Inconel 0.250 / 1.000 1 inch PZR vent nozzle SB-166 Nozzle to SS Class 1 pipe weld. (Examine the PZR surface where the PZR Vent Nozzle and the PZR Head/Shell interface and also examine the Nozzle to SS Pipe weld.)

Augmented Inspection Per Oconee response to BL-2004-01. Contact Jody Shuping for additional information on this examination.

Bare Metal Visual Examinations are to be performed each refueling outage by a VT-2 qualified inspector. Acceptance criteria is "no evidence of borated water leakage."

This weld was listed previously as 2-50-16-8A until it was transferred to iso 2RC-325.

This exam was performed during EOC-22 using summary number 02.G14.1.0022 and the id was 2-50-16-8A.

This weld will be examined during EOC-23 and future outages using summary number 02.G14.1.0023 and id 2RC-325-8A.

Dissimilar

_______________ _______ _________ ____ Pipe to Safe End ___

Category B-B 022.B2.40.0001 B02.040.001 2-.SGA-W23 50 OM-201.S-0156 NDE-820 UT CS 5.875 / 132.000 20T-245 Steam Generator 2A Upper Head to Upper Ci rcumferential Class 1 OM-201.S-0157 Tubesheet Head to Tubesheet 02.B2.40.0001 B02.040.001 2-SGA-W23 50 OM-201.S-0156 NDE-640 UT CS 5.875 /132.000 20T-245 Steam Generator 2A Upper Head to Upper Circumferential Class 1 OM-201.S-0157 Tubesheet Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 18 of 71

Oconee 2, 4th Intervjtage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched ThickuDia Cal Blocks Comments / HistoricalData Cafegor B-B Head to Tubesheet 02.B2.40.0002 B02.040.002 2-SGA-W22 50 OM-201.S-0156 NDE-820 UT CS 5.875/132.000 20T-245 Steam Generator 2A Lower Head to Lower Circumferential Class 1 OM-201.S-0157 Tubesheet Head to Tubesheet 02.B2.40.0002 B02.040.002 2-SGA-W22 50 OM-201.S-0156 NDE-640 UT CS 5.875/132.000 20T-245 Steam Generator 2A Lower Head to Lower Circumferential Class 1 OM-201.S-0157 Tubesheet Head to Tubesheet __________

Catepgor, B-D 02.B33.110.0012 B03.110.012 2-PZR-WP26-7 50 ISI-OCN2-002 NDE-640 UT CS 6.187 / 5.750 40338 Pressurizer Sampling Nozzle Pc. 30 to Heater Circumferential Class 1 OM-1201-456 Belt Shell Pc. 4. Z-W Quadrant, 40 Degrees off W- Axis.

Nozzle to Shell 02.B3.110.0012 B03.110.012 2-PZR-WP26-7 50 ISI-OCN2-002 NDE-820 UT CS 6.187 / 5.750 40338 Pressurizer Sampling Nozzle Pc. 30 to Heater Circumferential Class 1 OM-1201-456 Belt Shell Pc. 4. Z-W Quadrant, 40 Degrees off W- Axis.

Nozzle to Shell 02.B3.120.0012 B03.120.012 2-PZR-WP26-7 50 ISI-OCN2-002 NDE-680 UT CS 2.531 / 5.750 40338 Pressurizer Sampling Nozzle Pc. 30 to Heater OM-1201-456 50237E Belt Shell Pc. 4. Z-W Quadrant, 40 Degrees Class 1 off W-Axis. (Inside Radius Section)

B&W149771E Nozzle to Shell Printed 02/16/09ick8302 v.01/19/08 Cat "C" P 0 99SDQA Oconee 2 2/16/2009 10:32:23 AM Page 19 of 71

0 Summary Num Oconee 2, 4th Inte Insp itage 3 (EOC-23)

Component (D / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments lHistoricalData Catecior B-D 02.1B3.140.0001 B03.140.001 2-SGA-OUTLET 50 OM-201.S-0001 54-ISI-371 VT-1 CS 4.250 / 28.000 Steam Generator 2A Class 1 OM-201.S-0033 (Lower Head) Primary Outlet Nozzle at X-1/Y-2 Quadrant.

Inside Radius Section Enhanced VT-1 Inspection is required in lieu of UT inspection.

A vendor that is qualified for remote automated Visual examinations (Enhanced VT-1) will have to be contracted to perform this inspection.

Nozzle to Head 02.B3.140.0002 B03.140.002 2-SGA-OUTLET 50 OM-201.S-0001 54-ISI-371 VT-1 CS 4.250 / 28.000 Steam Generator 2A Class 1 OM-201.S-0033 (Lower Head) Primary Outlet Nozzle at X-2/Y-2 Quadrant.

Inside Radius Section Enhanced VT-1 Inspection is required in lieu of UT inspection.

A vendor that is qualified for remote automated Visual examinations (Enhanced VT-1) will have to be contracted to perform this inspection.

Nozzle to Head O2.B3.140.0003 B03.140.003 2-SGB-OUTLET 50 OM-201.S-0001 54-ISI-371 VT-1 CS 4.250 / 28.000 Steam Generator 2B Class 1 OM-201.S-0033 (Lower Head) Primary Outlet Nozzle at X-1/Y-2 Quadrant.

Inside Radius Section Enhanced VT-1 Inspection is required in lieu of UT inspection.

A vendor that is qualified for remote automated Visual examinations (Enhanced VT-1) will have to be contracted to perform this inspection.

Nozzle to Head Printed 02/16/09ick8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 20 of 71

0 Summary Num Oconee 2, 4th Inte Insp 4

.itage 3 (EOC-23)

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Cateaor B-D 02.B3.140.0004 1303.140.004 2-SGB-OUTLET 50 OM-2011.S-0001 54-ISI-371 VT-1 CS 4.250 / 28.000 Steam Generator 2B Class 1 OM-201.S-0033 (Lower Head) Primary Outlet Nozzle at X-2/Y-2 Quadrant.

Inside Radius Section Enhanced VT-1 Inspection is required in lieu of UT inspection.

A vendor that is qualified for remote automated Visual examinations (Enhanced VT-1) will have to be contracted to perform this inspection.

Nozzle to Head 02.B3.140.0005 B03.140.005 2-SGA-INLET 50 OM-201.S-0001 54-ISI-371 VT-1 CS 5.000 / 36.000 Steam Generator 2A Inlet Nozzle (Upper Class 1 OM-201.S-0157 Head) Inside Radius Section Enhanced VT-1 Inspection is required in lieu of UT inspection.

A vendor that is qualified for remote automated Visual examinations (Enhanced VT-1i) will have to be contracted to perform this inspection.

Nozzle to Head 02.83,140.0006 103.140.006 2-SGB-INLET 50 OM-201.S-0001 54-ISI-371 VT-1 CS 5.000 / 36.000 Steam Generator 2B Inlet Nozzle (Upper Class 1 OM-201.S-0157 Head) Inside Radius Section Enhanced VT-1 Inspection is required in lieu of UT inspection.

A vendor that is qualified for remote automated Visual examinations (Enhanced VT-1) will have to be contracted to perform this inspection.

Nozzle to Head Categor, B-G-1 02.B6.10.0021 B06.010.021 2-RPV-26-204-21 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.B6.10.0022 B06.010.022 2-RPV-26-204-22 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 21 of 71

0 Summary Num Oconee 2, 4th Inte Insp 4

itage 3 (EOC-23)

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments /Historical Data Categor B-G-1 02.B6.10.0023 B06.010.023 2-RPV-26-204-23 50 OM-1201-4 NDE-62 VT-1 CS 1.300 1 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.B6.10.0024 B06.01 0.024 2-RPV-26-204-24 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.86.10.0025 B06.010.025 2-RPV-26-204-25 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.16.10.0026 B06.010.026 2-RPV-26-204-26 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.86.10.0027 B06.010.027 2-RPV-26-204-27 50 OM-1201-4 NDE-62 VT-1 CS 1.300/9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.86.10.0028 B06.010.028 2-RPV-26-204-28 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.86.10.0029 B06.010.029 2-RPV-26-204-29 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.86.10.0030 B06.010.030 2-RPV-26-204-30 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E Printed 02/16/09lck8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 22 of 71

0 Summary Num Oconee 2, 4th Intervitage Insp 3 (EOC-23)

Component ID / Type System ISOIDWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Cateaor B-G-1 02.136.10.0031 B06.010.031 2-RPV-26-204-31 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.86.10.0032 B06.010.032 2-RPV-26-204-32 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.B6.10.0033 B06.010.033 2-RPV-26-204-33 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.B6.10.0034 B06.010.034 2-RPV-26-204-34 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.16.10.0035 B06.010.035 2-RPV-26-204-35 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.86.10.0036 B06.010.036 2-RPV-26-204-36 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.86.10.0037 B06.010.037 2-RPV-26-204-37 50 OM-1201-4 NDE-62 VT-i CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.86.10.0038 B06.010.038 2-RPV-26-204-38 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E Printed 02/16/09 Ick8302 v.. 6-1119ý0 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 23 of 71

0 Summary Num Oconee 2, 4th Inte Insp Jtage 3 (EOC-23)

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor B-G-1 02.1B6.110.0039 B06.010.039 2-RPV-26-204-39 50 OM-1201-4 NDE-62 VT-1 CS 1.300 / 9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.B6.10.0040 B06.010.040 2-RPV-26-204-40 50 OM-1201-4 NDE-62 VT-1 CS 1.300/9.250 Reactor Vessel Closure Nut Pc. 26.

Class 1 B&W152009E 02.B6.30.0021 B06.030.021 2-RPV-25-204-21 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.B6.30.0022 B06.030.022 2-RPV-25-204-22 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.B6.30.0023 B06.030.023 2-RPV-25-204-23 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.B6.30.0024 B06.030.024 2-RPV-25-204-24 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.86.30.0025 B06.030.025 2-RPV-25-204-25 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.B6.30.0026 B06.030.026 2-RPV-25-204-26 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 24 of 71

0 Summary Num Oconee 2, 4th Interv*

Insp tage 3 (EOC-23)

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments /Historical Data Catepor B-G-1 02.B6.30.0027 B06.030.027 2-RPV-25-204-27 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.B6.30.0028 B06.030.028 2-RPV-25-204-28 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.B6.30.0029 B06.030.029 2-RPV-25-204-51-62 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250. Stud # 2-RPV-25-204-29 was replaced with stud # 2-RPV-25-204-51-62 during 2EOC-21.

02.B6.30.0030 B06.030.030 2-RPV-25-204-30 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.B6.30.0031 B06.030.031 2-RPV-25-204-31 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.86.30.0032 B06.030.032 2-RPV-25-204-32 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.86.30.0033 B06.030.033 2-RPV-25-204-33 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.B6.30.0034 B06.030.034 2-RPV-25-204-34 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 - Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

Printed 02/16/09 lck8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 25 of 71

0 Summary Num Oconee 2, 4th IntervStage 3 (EOC-23)

Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Catepo' B-G-1 02.B6.30.0035 B06.030.035 2-RPV-25-204-35 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.B6.30.0036 B06.030.036 2-RPV-25-204-36 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.B6.30.0037 B06.030.037 2-RPV-25-204-37 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.B6.30.0038 B06.030.038 2-RPV-25-204-38 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.B6.30.0039 B06.030.039 2-RPV-25-204-39 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.B6.30.0040 B06.030.040 2-RPV-25-204-40 50 OM-1201-4 PDI-UT-5 UT CS 0.000 / 6.500 40420 Reactor Vessel Closure Stud Pc. 25 -

Class 1 B&W152009E Removed. Stud Length = 63.250.

02.B6.50.0002 B06.050.002 2-RPV-WASH-BUSH 50 B&W152009E NDE-62 VT-1 CS 0.000 / 9.750 Reactor Vessel Closure Washers and Class 1 Bushings. Stud Holes 21 thru 40.

Catepor B-G-2 02.B7.20.0002 B07.020.002 2-PZR-CHB-STUDS 50 B&W149775E NDE-62 VT-1 CS 0.000 / 2.000 Pressurizer Center Heater Bundle Studs Pc. 75 Class 1 and Nuts. 16 Studs, Length = 19.312".

Examine all studs and nuts.

Printed 02/16/091ck8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 26 of 71

Oconee 2, 4th Interva tage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor B-G-2 02.17.50.0003 B07.050.003 2-PZR-RC67-STUDS 50 OM-1201-1526 NDE-62 VT-1 CS 0.000 / 1.125 Pressurizer Relief Valve 2RC-67 Inlet Flange Class 1 B&W149762E Bolting. W-X Quadrant.

8 Studs and 16 Nuts, Length = 8.750".

Examine all studs and nuts.

02.87.50.0004 B07.050.004 2-PZR-RC68-STUDS 50 OM-1201-1526 NDE-62 VT-1 CS 0.000 / 1.125 Pressurizer Relief Valve 2RC-68 Inlet Flange Class 1 B&W149762E Bolting. X-Y Quadrant.

8 Studs and 16 Nuts, Length = 8.750".

Examine all studs and nuts.

Cateaor B-J 02.B9.11.0003 B09.011.003, B09.011.003A 2-PSP-3 50 ISI-OCN2-016 NDE-35 PT SS 0.531 / 4.000 Pressurizer Spray Piping. Elbow Pc. 91 to Circumferential Class 1 O-ISIN4-100A-2.2 Reducer Pc. 102. Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Stress Weld Elbow to Reducer 02.89.11.0003 B09.011.003, B09.011.003A 2-PSP-3 50 ISI-OCN2-016 PDI-UT-2 UT SS 0.531 / 4.000 Component Pressurizer Spray Piping. Elbow Pc. 91 to 0-ISIN4-100A-2.2 50307 Reducer Circumferential Class 1 Pc. 102. Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Stress Weld Elbow to Reducer

-ýrinted 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 27 of 71

Oconee 2, 4th Interv0tage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor B-J 02.B9.11.0004 B09.01 1.004, B09.011.004A 2-PIB2-3 50 ISI-OCN2-010 NDE-25 MT CS 2.330 / 33.500 Reactor Coolant Pump 2B2 Circumferential Class 1 OM-1201-966 Suction Piping. Elbow Pc. 45 to Pipe Pc. 63. Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Stress Weld Elbow to Pipe 02.89.11.0004 B09.011.004, B09.011.004A 2-PIIB2-3 50 ISI-OCN2-010 NDE-600 UT CS 2.330 / 33,500 Component Reactor Coolant Pump 282 OM-1201-966 40350 Suction Piping. Elbow Circumferential Class 1 Pc. 45 to Pipe Pc. 63. Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Stress Weld Elbow to Pipe 02.B9.11.0005 Elbow to Pipe B09.011.005, B09.011.005A 2RC-279-89V 50 ISI-OCN2-005 NDE-25 MT CS 3.500 / 36.000 Steam Generator 2A Hot Leg. Elbow Pc. 1A to Circumferential Class 1 2RC-279 Elbow. Weld 89V is listed on weld iso 2RC-279 O-SIN4-100A72.1 but drawing ISI-OCN2-005 is listed as the iso to show where the weld is located on the 2A Hot Leg Piping Loop.

Elbow to Elbow 02.89.11.0005 B09.011.005, B09.011.005A 2RC-279-89V 50 ISI-OCN2-005 NDE-600 UT CS 3.500 / 36.000 Component Steam Generator 2A Hot Leg. Elbow Pc. 1A to Circumferential Class 1 2RC-279 Elbow. Weld 89V is listed on weld iso 2RC-279 O-SIN4-100A-2.1 but drawing ISI-OCN2-005 is listed as the iso to show where the weld is located on the 2A Hot Leg Piping Loop.

Elbow to Elbow Printed 02/16/09ick8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 28 of 71

Oconee 2, 4th Intervotage3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Catepor B-J 02.B9.111.0023 B09.011.023, B09.011.023A 2SGA-W2 50 ISI-OCN2-007 NDE-25 MT CS 3.500 / 33.500 Steam Generator 2A Outlet Nozzle to Pump Circumferential Class 1 O-ISIN4-100A-2.1 2A1 Suction Piping Weld W2 is listed on OM OM 201 .S--0033.001 201 .S--0033.001 but drawing ISI-OCN2-007 is listed as the iso to show where the weld is located on the 2A1 Suction Piping Loop.

Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Cal Block 40350 to be used where the thickness is between 2.10 inches and 3.55 inches and Cal Block 40339 to be used where the thickness exceeds 3.55 inches.

Terminal End Nozzle to Pipe 02.B9.111.0023 B09.011.023, B09.011.023A 2SGA-W2 50 ISI-OCN2-007 NDE-600 UT CS 3.500 / 33.500 Component Steam Generator 2A Outlet Nozzle to Pump O-ISIN4-10OA-2.1 40339 2A1 Suction Piping Weld W2 is listed on OM 40350 201 .S--0033.001 but drawing ISI-OCN2-007 is listed as the iso to show where the weld is Circumferential Class 1 located on the 2A1 Suction Piping Loop.

OM 201.S--0033.001 Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Cal Block 40350 to be used where the thickness is between 2.10 inches and 3.55 inches and Cal Block 40339 to be used where the thickness exceeds 3.55 inches.

Terminal End Nozzle to Pipe Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" PAOconee 2 2/16/2009 10:32:23 AM Page 29 of 71

Oconee 2, 4th Intervetage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISOIDWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Cate-gor B-J 02.B9.111.0025 B09.011.025, B09.011.025A 2SGA-W3 50 ISI-OCN2-008 NDE-25 MT CS 3.500 / 33.500 Steam Generator 2A Outlet Nozzle To Pump Circumferential Class 1 O-ISIN4-100A-2.1 2A2 Suction Piping Pc. 67.

OM 201 .S--0033.001 Weld W3 is listed on OM 201 .S--0033.001 but drawing ISI-OCN2-008 is listed as the iso to show where the weld is located on the 2A2 Suction Piping Loop.

Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Cal Block 40350 to be used where the thickness is between 2.10 inches and 3.55 inches and Cal Block 40339 to be used where the thickness exceeds 3.55 inches.

Terminal End Nozzle to Pipe 02.B9.11.0025 B09.011.025, B09.011.025A 2SGA-W3 50 ISI-OCN2-008 NDE-600 UT CS 3.500 / 33.500 Component Steam Generator 2A Outlet Nozzle To Pump O-ISIN4-10OA-2.1 40339 2A2 Suction Piping Pc. 67.

40350 Weld W3 is listed on OM 201 .S--0033.001 but drawing ISI-OCN2-008 is listed as the iso to Circumferential Class 1 show where the weld is located on the 2A2 OM 201.S--0033.001 Suction Piping Loop.

Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Cal Block 40350 to be used where the thickness is between 2.10 inches and 3.55 inches and Cal Block 40339 to be used where the thickness exceeds 3.55 inches.

Terminal End Nozzle to Pipe Printed 02/16/091ck8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 30 of 71

0 Oconee 2, 4th Intervltage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Catepo, B-J 02.B9.111.0027 B09.011.027, B09.011.027A 2SGB-W3 50 ISI-OCN2-009 NDE-25 MT CS 3.500 / 33.500 Steam Generator 2B Outlet Nozzle to Pump Circumferential Class 1 OM 201.S--0033.001 2B1 Suction Piping.

O-ISIN4-100A-2.1 Weld 2SGB-W3 is listed on drawing OM 201 .S--0033.001 but drawing lSI-OCN2-009 is listed as the iso to show where the weld is located on the 2B1 Suction Piping Loop.

Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Cal Block 40350 to be used where the thickness is between 2.10 inches and 3.55 inches and Cal Block 40339 to be used where the thickness exceeds 3.55 inches.

Terminal End Nozzle to Pipe 02.B9.11.0027 B09.011.027, B09.011.027A 2SGB-W3 50 ISI-OCN2-009 NDE-600 UT CS 3.500 / 33.500 Component Steam Generator 2B Outlet Nozzle to Pump OM 201 .S--0033.001 40339 281 Suction Piping.

40350 Weld 2SGB-W3 is listed on drawing OM 201 .S--0033.001 but drawing ISI-OCN2-Circumferential Class 1 009 is listed as the iso to show where the weld O-ISIN4-100A-2.1 is located on the 2B1 Suction Piping Loop.

Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Cal Block 40350 to be used where the thickness is between 2.10 inches and 3.55 inches and Cal Block 40339 to be used where the thickness exceeds 3.55 inches.

Terminal End Nozzle to Pipe Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 31 of 71

Oconee 2, 4th Interv0tage 3 (EOC-23)

Summary Num lnsp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor B-J 02.139.111.00311 02.B.11.031B09.011.031, B09.01 1.031A 2-PIB2-8 50 ISI-OCN2-010 NDE-35 PT SS 2.780 / 33.500 Reactor Coolant Pump 2B2 Casing to Safe Circumferential Class 1 OM-1201-966 End Pc. 55. Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used. Procedure NDE-830 and Cal Block 50214 are to be used only for a supplemental UT performed from the pump side. The supplemental exam is being performed as requested by Jim McArdle which will be used to justify limited coverage from the code exam (performed using NDE-600 or PDI-UT-2).

Stress Weld Terminal End Casing to Safe End 02.69.11.0031 B09.01 1.031, B09.011 .031A 2-PIB2-8 50 ISI-OCN2-010 NDE-830 UT SS 2.780 / 33.500 Component Reactor Coolant Pump 2B2 Casing to Safe OM-1201-966 40397 End Pc. 55. Procedure NDE-600 uses the 50214 component for calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If Circumferential Class 1 PDI-UT-2 is used, then the calibration block listed shall be used. Procedure NDE-830 and Cal Block 50214 are to be used only for a supplemental UT performed from the pump side. The supplemental exam is being performed as requested by Jim McArdle which will be used to justify limited coverage from the code exam (performed using NDE-600 or PDI-UT-2).

Stress Weld Terminal End Casing to Safe End 02.89.11.0031 B09.011.031, B09.011.031A 2-PIB2-8 50 ISI-OCN2-010 NDE-600 UT SS 2.780 / 33.500 Component Reactor Coolant Pump 262 Casing to Safe OM-1201-966 40397 End Pc. 55. Procedure NDE-600 uses the 50214 component for calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If Circumferential Class 1 PDI-UT-2 is used, then the calibration block listed shall be used. Procedure NDE-830 and Cal Block 50214 are to be used only for a supplemental UT performed from the pump side. The supplemental exam is being performed as requested by Jim McArdle which Printed 02/16/09 Ick8302 v. 01 /19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 32 of 71

Oconee 2, 4th Intervotage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categaor, B-J will be used to justify limited coverage from the code exam (performed using NDE-600 or PDI-UT-2).

Stress Weld Terminal End Casing to Safe End 02.139.11.0043 B09.011.043, B09.011.043A 2RC-279-91V 50 ISI-OCN2-007 NDE-25 MT CS 3.500 / 33.500 Reactor Coolant Pump 2A1 Circumferential Class 1 2RC-279 Suction Piping to Elbow Pc. 45. Weld 91V is 0-ISIN4-10OA-2.1 listed on weld iso 2RC-279 but drawing ISI-OCN2-007 is listed as the iso to show where the weld is located on the 2A1 Suction Piping Loop.

Stress Weld Pipe to Elbow 02.B9.11.0043 B09.011.043, B09.01 1.043A 2RC-279-91V 50 ISI-OCN2-007 NDE-600 UT CS 3.500 / 33.500 Component Reactor Coolant Pump 2A1 Circumferential Class 1 2RC-279 Suction Piping to Elbow Pc. 45. Weld 91V is O-ISIN4-100A-2.1 listed on weld iso 2RC-279 but drawing ISI-OCN2-007 is listed as the iso to show where the weld is located on the 2A1 Suction Piping Loop.

Stress Weld Pipe to Elbow 02.B9.11.0044 B09.011.044, B09.011.044A 2-PIA1-3 50 ISI-OCN2-007 NDE-25 MT CS 2.330 / 33.500 Reactor Coolant Pump 2A1 Circumferential Class 1 OM-1201-966 Suction Piping. Elbow Pc. 45 to Pipe Pc. 63. Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Stress Weld Elbow to Pipe 02.B9.11.0044 109.011.044, B09.011.044A 2-PIA1-3 50 iSI-OCN2-007 PDI-UT-1 UT CS 2.330 / 33.500 Component Reactor Coolant Pump 2A1 OM-1201-966 40350 Suction Piping. Elbow Circumferential Class 1 Pc. 45 to Pipe Pc. 63. Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C Oconee 2 2/16/2009 10:32:23 AM Page 33 of 71

0 Oconee 2, 4th Interv~tage3 (EOC-23)

Insp Summary Num Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor B-J calibration block listed shall be used.

Stress Weld Elbow to Pipe 02.B9.11.0049 B09.011.049, B09.011.049A 2-2RC-279-90V 50 ISI-OCN2-008 NDE-25 MT CS 3.500 / 33.500 Reactor Coolant Pump 2A2 Circumferential Class 1 0-ISIN4-100A-2.1 Suction Piping. Pipe to Elbow Pc. 45.

OM 201 .S--0033.001 Weld 90V is listed on weld iso 2RC-279 but drawing ISI-OCN2-008 is listed as the iso to show where the weld is located on the 2A2 Suction Piping Loop.

Stress Weld Pipe to Elbow 02.B9.11.0049 B09.011.049, B09.011.049A 2-2RC-279-90V 50 ISI-OCN2-008 NDE-600 UT CS 3.500 / 33.500 Component Reactor Coolant Pump 2A2 Circumferential Class 1 0-ISIN4-100A-2.1 Suction Piping. Pipe to Elbow Pc. 45.

OM 201 .S--0033.001 Weld 90V is listed on weld iso 2RC-279 but drawing ISI-OCN2-008 is listed as the iso to show where the weld is located on the 2A2 Suction Piping Loop.

Stress Weld Pipe to Elbow 02.B9.111.0055 B09.011.055, B09.011.055A 2RC-279-95V 50 ISI-OCN2-009 NDE-25 MT CS 3.500 / 33.500 Reactor Coolant Pump 2B1 Circumferential Class 1 2RC-279 Suction Piping. Pipe to Elbow Pc. 45.

O-ISIN4-10OA-2.1 Weld 95V is listed on weld iso 2RC-279 but drawing ISI-OCN2-009 is listed as the iso to show where the weld is located on the 2B1 Suction Piping Loop.

Stress Weld Pipe to Elbow 02.B9.11.0055 B09.011.055, B09.011.055A 2RC-279-95V 50 ISI-OCN2-009 NDE-600 UT CS 3.500 / 33.500 Component Reactor Coolant Pump 2B1 Circumferential Class 1 2RC-279 Suction Piping. Pipe to Elbow Pc. 45.

O-ISIN4-100A-2.1 Weld 95V is listed on weld iso 2RC-279 but drawing ISI-OCN2-009 is listed as the iso to show where the weld is located on the 2B1 Suction Piping Loop.

Stress Weld Pipe to Elbow Printed 02/16/09ick8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 34 of 71

0 Oconee 2, 4th IntervStage 3 (EOC-23)

Insp Summary Num Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Cate0ori, B-J 02.139.11.0056 B09.011.056, B09.011.056A 2-PIB1-3 50 ISI-OCN2-009 NDE-25 MT CS 2.330 / 33.500 Reactor Coolant Pump 2B1 Circumferential Class 1 OM-1201-966 Suction Piping. Elbow Pc. 45 to Pipe Pc. 63. Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Stress Weld.

Elbow to Pipe 02.139.11.0056 B09.011.056, B09.011 .056A 2-PIB1-3 50 iSI-OCN2-009 NDE-600 UT CS 2.330 / 33.500 Component Reactor Coolant Pump 281 OM-1201-966 40350 Suction Piping. Elbow Circumferential Class 1 Pc. 45 to Pipe Pc. 63. Procedure NDE-600 uses the component for calibration. Procedure PD1-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Stress Weld

-Elbow to Pipe 02.89.11.0058 B09.011.058, B09.011.058A 2-PIB1-8 50 ISI-OCN2-009 NDE-35 PT SS 2.780 / 33.500 Reactor Coolant Pump 281 Suction Piping.

Circumferential Class 1 OM-1201-966 RCP 281 Casing to Safe End Pc. 55.

Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used. Procedure NDE-830 and Cal Block 50214 are to be used only for a supplemental UT performed from the pump side. The supplemental exam is being performed as requested by Jim McArdle which will be used to justify limited coverage from the code exam (performed using NDE-600 or PDI-UT-2).

Stress Weld Terminal End Casing to Safe End 02.89.11.0058 B09.011.058, B09.011.058A 2-PIB1-8 50 ISI-OCN2-009 NDE-600 UT SS 2.780 / 33.500 Component Reactor Coolant Pump 281 Suction Piping.

OM-1201-966 40397 RCP 281 Casing to Safe End Pc. 55.

50214 Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-2 may be used Circumferential Class 1 Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 35 of 71

Oconee 2, 4th Interv-tage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor B-J in lieu of procedure NDE-600. If PDI-UT-2 is used,.then the calibration block listed shall be used. Procedure NDE-830 and Cal Block 50214 are to be used only for a supplemental UT performed from the pump side. The, supplemental exam is being performed as requested by Jim McArdle which will be used to justify limited coverage from the code exam (performed using NDE-600 or PDI-UT-2).

Stress Weld Terminal End Casing to Safe End 02.B9.11.0058 B09.011.058, B09.011.058A 2-PIB1-8 50 ISI-OCN2-009 NDE-830 UT SS 2.780 / 33.500 Component Reactor Coolant Pump 2B1 Suction Piping.

OM-1201-966 40397 RCP 2B1 Casing to Safe End Pc. 55.

50214 Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-2 may be used Circumferential Class 1 in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used. Procedure NDE-830 and Cal Block 50214 are to be used only for a supplemental UT performed from the pump side. The supplemental exam is being performed as requested by Jim McArdle which will be used to justify limited coverage from the code exam (performed using NDE-600 or PDI-UT-2).

Stress Weld Terminal End Casing to Safe End 02.B9.11.0067 B09.011.201, B09.011.201A 2-53A-1 0-3 53A 2-53A-10 NDE-35 PT SS 1.125 / 12.000 Procedure NDE-600 uses the component for Circumferential Class 1 O-ISIN4-102A-2.1 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Valve 2LP-1 to Pipe 02.B9.11.0067 B09.011.201, B09.011.201A 2-53A-1 0-3 53A 2-53A-10 PDI-UT-2 UT SS 1.125 /12.000 Component Procedure NDE-600 uses the component for 0-ISIN4-102A-2.1 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used Circumferential Class 1 in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Valve 2LP-1 to Pipe Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 36 of 71

0 Oconee 2, 4th Interv tage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Cateaor B-J 02.B9.11.0071 B09.011.207, B09.011.207A 2-53A-8-43 53A 2-53A-8(2) NDE-35 PT SS 1.250 / 14.000 Procedure NDE-600 uses the component for Circumferential Class 1 0-ISIN4-102A-2.3 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.B9.11.0071 B09.011.207, B09.011.207A 2-53A-8-43 53A 2-53A-8(2) PDI-UT-2 UT SS 1.250114.000 Component Procedure NDE-600 uses the component for 0-ISIN4-102A-2.3 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used Circumferential Class 1 in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.89.21.0015 B09.021.015 2RC-253-5 50 2RC-253 NDE-35 PT SS 0.281 / 1.500 Circumferential Class 1 0-ISIN4-100A-2.2 Stress Weld Tee to Pipe 02.89.21.0016 B09.021.016 2RC-253-6 50 2RC-253 NDE-35 PT SS 0.281 / 1.500 Circumferential Class 1 0-ISIN4-100A-2.2 Stress Weld Pipe to Valve 2LP-46 02.89.21.0021 B09.021.021 2-PSP-14 50 ISI-OCN2-016 NDE-35 PT SS 0.375 / 2.500 Pressurizer Spray Piping. Elbow Pc. 98 to Tee Circumferential Class 1 O-ISIN4-100A-2.2 Pc. 105.

Stress Weld Elbow to Tee 02.89.21.0030 B09.021.107 2HP-216-9 51A 2HP-216 NDE-35 PT SS 0.375 / 2.500 This weld was listed previously as 2-51A-30-54 Circumferential Class 1 0-ISIN4-101A-2.4 until iso 2-51A-30 was redrawn.

Stress Weld Pipe to Valve 2HP-486 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 37 of 71

Oconee 2, 4th Intervltage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor B-J 02.B9.21.0049 B09.021.126 2-51 A-30-15 51A 2-51A-30 NDE-35 PT SS 0.375 / 2.500 Circumferential Class 1 O-ISIN4-101A-2.4 Pipe to Pipe 02.B9.21.0052 B09.021.129 2-51A-30-40 51A 2-51A-30 NDE-35 PT SS 0.375 / 2.500 Circumferential Class 1 O-ISIN4-101A-2.4 Elbow to Pipe 02.B9,21.0054 B09.021.131 2-51A-35-28A 51A 2-51A-35 (2) NDE-35 PT SS 0.375/ 2.500 Circumferential Class 1 O-ISIN4-101A-2.1 Pipe to Elbow 02.B9.21.0055 B09.021.132 2-51A-35-33 51A 2-51A-35(2) NDE-35 PT SS 0.375/ 2.500 Circumferential Class 1 0-ISIN4-101A-2.1 Pipe to Elbow 02.B9.21.0228 2HP-495-26 51A 2HP-495 NDE-35 PT SS 0.375/2.500 Letdown Cooler 2A. Inlet Nozzle to Elbow.

Class 1 0-ISIN4-101A-2.1 This weld was listed previously as 2-51A-1 47-26 until it was transferred to iso 2HP-495.

Terminal End Pipe to Pipe 02.B9.31.0002 B09.031.002, B09.031.002A 2-PHA-16 50 ISI-OCN2-005 NDE-25 MT CS 2.875 / 25.000 Steam Generator 2A Hot Leg to Reactor Branch Class 1 B&W146330E Vessel. Decay Heat Nozzle Pc. 34 to Pipe Pc.

32. NPS of Branch Piping is 12 inches.

Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used. MT or PT or a combination of the two methods together are exceptable to meet the surface examination requirements.

Stress Weld Nozzle to Pipe Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 38 of 71

Oconee 2, 4th Interv0tage3 (EOC-23)

Summary Num Insp Component ID / Type System ISOIDWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Category B-J 02.B9.32.0006 B09.032.006 2-PIAl-10 50 ISI-OCN2-007 NDE-25 MT CS 2.250/ 12.000 Reactor Coolant Pump 2A1 Suction Piping.

Branch Class 1 OM-1201-966 Drain Nozzle Pc. 64 to Pipe Pc. 63.

B&W146623E NPS of Branch Piping is 1.5 inches.

Stress Weld Nozzle to Pipe 02.B9.40.0004 B09.040.004 2RC-271-3B 50 2RC-271 NDE-35 PT SS 0.281 11.500 This weld was listed previously as 2-50-129-3B Socket Class 1 0-ISIN4-100A-2.2 until iso 2-50-129 was deleted and all welds were tranferred to iso 2RC-271.

Elbow to Pipe 02.B9.40.0006 B09.040.006 2-50-7-127 50 2-50-7 (1) NDE-35 PT SS 0.281 /1.500 Socket Class 1 0-ISIN4-100A-2.1 Pipe to Valve 2RC-24 02.B9.40.0011 B09.040.101 2-51A-145-26 51A 2-51A-145 NDE-35 PT SS 0.344 / 2.000 Socket Class 1 0-ISIN4-101A-2.1

_________________ Pipe to Valve 2HP4 ____

Categor B-K 02.B131.110.0006 B10.010.006 2-PZR-WP82-Y ISI-OCN2-002 NDE-25 MT CS 3.500 / 0.000 Pressurizer Support Lug Assembly PC.110 to Class 1 0-ISIN4-100A-2.2 Lower Shell Course Pc.3. Y Axis.

Dave Peltola selected this lug to be examined which will meet the requirements of Code Case N-700.

(see letter dated 11-1-07 from Dave Peltola)

Support Lug to Shell 02.B130.20.0002 B10.020.011 2-51A-0-1478A-H5C 51A 0-2RB-25112-01 NDE-35 PT NA 0.500 / 2.500 Calculation No. OSC-1660-06.

Rigid Support Class 1 0-ISlN4-101A-2.1 Inspect with F01 .010.014.

Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 39 of 71

Oconee 2, 4th Interv*tage 3 (EOC-23)

Summary Num - Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor B-K 02.1310.20.0004 B10.020.013 2-51 A-0-1 479A-H 7B 51A 2-51-24 NDE-35 PT NA 0.312 / 2.500 Calculation No. OSC-1323.

Rigid Restraint Class 1 O-ISIN4-101A-2.4 HPI West Coolant Loop.

Inspect with F01.011.014.

Cateiof2 B-M-2 02.1312-50.0002 B1 2.050.002 2-53A-CF12 53A OM-245-001 NDE-64 VT-3 SS 0.000/14.000 A-Side Core Flood Valve Body 2CF-12 Internal Class 1 0-ISIN4-102A-2.3 Surfaces. W-Axis. Inspect one of the following valves: 2CF-11, 2CF-12, 2CF-13, or 2CF-14 only if valve is disassembled for maintenance, repair, or volumetric examination.

Cate-gory B-N-I-02.1313.10.0001 B133.010.001 2-RPV-INT-SURFACE 50 B&W152008E NDE-63 VT-3 SS 0.000 / 0.000 Reactor Vessel Interior. Areas to be examined Class 1 ISI-OCN2-001 shall include the spaces above and below the Reactor Core that are made accessible for examination by removal of components during normal refueling outages.

For the examination performed during the third period, a vendor that is qualified for remote automated Visual examinations (Enhanced VT-1 and VT-3) will have to be contracted to perform this inspection.

Cate-go B-0 02.1314.10.0001 B14.010.001 2-RPV-CRD-52WH-9 50 OM-201.R--0106.001 NDE-35 PT SS-Inconel 0.650 / 4.025 CRDM #52 Housing Body to Adapter.

Class 1 OM-201-3161 Dissimilar Housing Body to Adapter 02.B14.10.0004 B14.010.004 2-RPV-CRD-52W6 0 50 OM-201-3160 NDE-35 PT SS-CS 0.500 / 5.000 CRDM #52 Base to Motor Tube.

Class 1 OM-201-3161 Base to Motor Tube Printed 02/16/091ck8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 40 of 71

Oconee 2, 4th lnten,*tage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor, B-0 02.B14.10.0007 B14.010.007 2-RPV-CRD-52 50 OM-201-3160 NDE-35 PT SS-CS 0.400 / 4.300 CRDM #52 Motor Tube to Extension.

Class 1 OM-201-3161 Motor Tube to Extension 02.B14.10.0010 B14.010.010 2-RPV-CRD-52W61 50 OM-201-3160 NDE-35 PT SS 0.380 / 4.190 CRDM #52 Extension to Cap.

Class 1 OM-201-3161 Extension to Cap Categorj2 C-A 02.Cl .30.0007 2-RCSRCA-SH-TS-1 51A OM 201-3218 NDE-35 PT SS 0.165 / 0.000 Reactor Coolant Seal Return Cooler 2A. Weld Circumferential ClI ass 2 O-ISIN4-101A-2.1 located next to inlet piping. ComplD was 2-OM 201-086 LPCB-SH-TUBE until changed by addendum ONS2-038.

Shell to Tubesheet 02.Cl .30.0008 C01.030.004 2-RCSRCA-SH-TS-2 51A OM 201-3218 NDE-35 PT SS 0.165 / 0.000 Reactor Coolant Seal Return Cooler 2A. Weld Circumferential Class 2 O-ISlN4-101A-2.1 located next to outlet piping.

OM 201-086 Shellto Tubesheet Categor C-B 02.C2.21.0002 C02.021.002, C02.021.002A 2-SGA-W128 OM-201.S-0001 NDE-25 MT CS 5.125 / 24.000 Steam Generator 2A Main Steam Nozzle to Circumferential Class 2 OM-201.S-0026 Shell.

X-2/Y-1 Quadrant.

OM-201.S-0157 Nozzle to Shell 02.C2.21.0002 C02.021.002, C02.021.002A 2-SGA-W128 OM-201.S-0001 NDE-820 UT CS 5.125 / 24.000 20T-240 Steam Generator 2A Main Steam Nozzle to Circumferential Class 2 OM-201.S-0026 Shell.

OM-201.S-0157 X-21Y-1 Quadrant.

Nozzle to Shell 02.C2.21.0002 C02.021.002, C02.021.002A Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 41 of 71

Oconee 2, 4th JntervOtage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched ThicklDia Cal Blocks Comments / HistoricalData Categor C-B 2-SGA-W128 OM-201 .S-0001 NDE-640 UT CS 5.125 /24.000 20T-240 Steam Generator 2A Main Steam Nozzle to Circumferential Class 2 OM-201.S-0026 Shell.

OM-201.S-0157 X-2/Y-1 Quadrant.

Nozzle to Shell Cateaor. C-C 02.C3.20.0006 C03.020.012 2-03-0-1480A-H7A 03 0-1490B-4(S) NDE-25 MT CS 0.237 / 24.000 Calculation No. OSC-1313-06(Vol.B). Inspect Hyd Snubber Class 2 0-ISIN4-121B-2.3 with F01.022.012.

2-03-05/sht.3 02.C3.20.0011 C03.020.023 2-14B-0-11479A-H 12 14B 0-1492A-5(S) NDE-25 MT CS 0.750 / 6.000 Calculation No. OSC-1 325-06. Inspect with Rigid Restraint Class 2 0-ISIN4-124B-2.2 F01.021.022.

2-14-16/sht.1 02.C3.20.0015 C03.020.033 2-51A-1-0-436J-SR116 51A 0-2AB-25102-01 NDE-35 PT SS 0.750 / 4.000 Calculation No. OSC-481. Inspect with Rigid Restraint Class 2 0-ISIN4-101A-2.3 F01.021.043.

02.C3.20.0017 C03.020.035 2-51A-0-1478A-H1OC 51A 2-51-12/sht.5 NDE-35 PT SS 0.500 / 2.500 Calculation No. OSC-1660-06. Inspect with Rigid Support Class 2 0-ISIN4-101A-2.1 F01.020.051.

02,C3.20.0020 C03.020.041 2-53-0-1478A-H5 53 0-2RB-25310-03 NDE-35 PT SS 0.337 / 12.000 Calculation No. OSC-1320-06. Inspect with Rigid Restraint Class 2 0-ISIN4-102A-2.1 F01.021.067.

02.C3.20.0022 C03.020.043 2-53B-10-0-435B-H2 53B 0-2AB-25301-03 NDE-35 PT SS 0.216 / 8.000 Calculation No. OSC-487. Inspect with Spring Hgr Class 2 0-ISIN4-102A-2.2 F01.022.052.

02.C3.20.0026 C03.020.047 2-53B-5-0-1439C-H31 53B 0-2AB-25302-01 NDE-35 PT SS 0.500 /10.000 Calculation No. OSC-493. Inspect with Rigid Support Class 2 0-ISIN4-102A-2.2 F01.020.082.

Printed 02/16/091ck8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 42 of 71

0 Oconee 2, 4th Interv*tage 3 (EOC-23)

Insp Summary Num Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor C-D 02.C4.30.0001 C04.030.001 2-HPI-PUMP-2A 51A OM-201-1704 PDI-UT-5 UT SS 0.000 / 2.500 40422 HPI Pump 2A Bolting on Pump Casing. 20 Class 2 O-ISIN4-101A-2.3 Studs, Length = 12.000".

The bolting on only one of the HPI Pumps 2A, 2B, or 2C is required to be examined. Due to inaccessibility, disassembly is required, therefore they will be scheduled for Outages 1, 2, 5, or 6. Examine upon disassembly for maintenance or disassembly will be required in order to perform the examination. This examination cannot be performed in the second period (Outages 3 or 4) in accordance with the requirements of IWC-2412(a).

HPI Pumps (C4.30 items) were originally sheduled for the first period and third period for the fourth interval. Due to maintenance activities , Pump 2A was made accesible to inspect in outage 3 which is in the second period. We moved the inspection to outage 3 for Pump 2A and then scheduled item 02.C4.40.0001 for the 3rd period to meet the percentage requirements for category C-D.

Categoo C-F-1 02.C5.11.0005 C05.011.005, C05.011.005A 2LP-150-17 53A 2LP-150 NDE-35 PT SS 1.125 / 10.000 Procedure NDE-600 uses the component for Circumferential Class 2 O-ISIN4-102A-2.3 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used. This weld was listed previously as 2-53A-9-17 until iso 2-53A-9 was redrawn.

Pipe to Valve 2LP-48 02.C5.11.0005 C05.011.005, C05.011.005A 2LP-150-17 53A 2LP-150 PDI-UT-2 UT SS 1.125 / 10.000 Component Procedure NDE-600 uses the'component for 0-ISIN4-102A-2.3 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used Circumferential Class 2 in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used. This weld was listed previously as 2-53A-9-17 until iso 2-53A-9 was redrawn.

Pipe to Valve 2LP-48 Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 43 of 71

Oconee 2, 4th Interv-tage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments /Historical Data Categqory C-F-I 02.C5.11.0021 C05.011.021, C05.011.021A 2LP-217-8 53A 2LP-217 NDE-35 PT SS 1.000 / 10.000 Procedure NDE-600 uses the component for Circumferential Class 2 O-ISIN4-102A-2.3 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Valve 2LP-1 78 to Pipe 02.C5.11.0021 C05.01 1.021, C05.01 1.021A 2LP-217-8 53A 2LP-217 PDI-UT-2 UT SS 1.000 / 10.000 Component Procedure NDE-600 uses the component for O-ISIN4-102A-2.3 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used Circumferential Class 2 in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Valve 2LP-1 78 to Pipe_

02.C5.11.0022 C05.011.022, C05.011.022A 2-53A-9-1 0 53A 2-53A-9 NDE-35 PT SS 1.000 / 10.000 Procedure NDE-600 uses the component for Circumferential Class 2 O-ISIN4-102A-2.2 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.11.0022 C05.011.022, C05.011.022A 2-53A-9-10 53A 2-53A-9 PDI-UT-2 UT SS 1.000 / 10.000 Component Procedure NDE-600 uses the component for 0-ISIN4-102A-2.2 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used Circumferential Class 2 in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.11.0023 C05.011.023, C05.011.023A 2-53A-9-11 53A 2-53A-9 NDE-35 PT SS 1.000 / 10.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-102A-2.2 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.11.0023 C05.011.023, C05.011.023A Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cal "C" Oconee 2 2/16/2009 10:32:23 AM Page 44 of 71

Oconee 2, 4th Interv*tage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Catepor C-F-1 2-53A-9-11 53A 2-53A-9 PDI-UT-2 UT SS 1.000 / 10.000 Component Procedure NDE-600 uses the component for O-ISIN4-102A-2.2 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used Circumferential Class 2 in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.11.0024 C05.011.024, C05.011.024A 2-53A-9-12 53A 2-53A-9 NDE-35 PT SS 1.000 / 10.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-102A-2.2 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.11.0024 C05.011.024, C05.011.024A 2-53A-9-12 53A 2-53A-9 PDI-UT-2 UT SS 1.000 / 10.000 Component Procedure NDE-600 uses the component for 0-ISIN4-102A-2.2 PDI-UT-2-0 calibration. Procedure PD17UT-2 may be used Circumferential Class 2 in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.1 1.0025 C05.011.025, C05.011.025A 2-53A-9-16 53A 2-53A-9 NDE-35 PT SS 1.000 / 10.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-102A-2.2 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Valve 2LP-48 02.C5.11.0025 C05.011.025, C05.011.025A 2-53A-9-16 53A 2-53A-9 PDI-UT-2 UT SS 1.000 / 10.000 Component Procedure NDE-600 uses the component for 0-ISIN4-102A-2.2 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is Circumferential Class 2 used, then the calibration block listed shall be used.

Pipe to Valve 2LP-48 Printed 02/16/09 Ick8302 v. 01/19/08 -ib -QA--Ca-t-"'-C-"" Oconee 2 2/16/2009 10:32:23 AM Page 45 of 71

Oconee 2, 4th Interv*tage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments /Historical Data Catepor C-F-1 02.C5.11.0026 C05.011.026, COS5l 11.026A 2-53A-9-4 53A 2-53A-9 NDE-35 PT SS 1.000 / 10.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-102A-2.2 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.11.0026 C05.011.026, C05.011.026A 2-53A-9-4 53A 2-53A-9 PDI-UT-2 UT SS 1.000 / 10.000 Component Procedure NDE-600 uses the component for O-ISIN4-102A-2.2 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used Circumferential Class 2 in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.11.0027 C05.011.027, C05.011.027A 2-53A-9-5 53A 2-53A-9 NDE-35 PT SS 1.000 / 10.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-102A-2.2 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.11.0027 C05.011.027, C05.011.027A 2-53A-9-5 53A 2-53A-9 PDI-UT-2 UT SS 1.000 / 10.000 Component Procedure NDE-600 uses the component for 0-ISIN4-102A-2.2 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is Circumferential Class 2 used, then the calibration block listed shall be used.

_____Pipe to Elbow 02.C5.11.0028 C05.011.028, C05.011.028A 2-53A-9-6 53A 2-53A-9 NDE-35 PT SS 1.000 /10.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-102A-2.2 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.11.0028 C05.011.028, C05.011.028A Printed 02/16/09ick8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 46 of 71

Oconee 2, 4th Intervetage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia CalBlocks Comments / HistoricalData Categor C-F-1 2-53A-9-6 53A 2-53A-9 PDI-UT-2. UT SS 1.000 / 10.000 Component Procedure NDE-600 uses the component for O-ISIN4-102A-2.2 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is Circumferential Class 2 used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.11.0033 C05.011.033, C05.011.033A 2LP-189-13 53A 2LP-189 NDE-35 PT SS 1.000 / 10.000 Procedure NDE-600 uses the component for Circumferential Class 2 O-ISIN4-102A-2.2 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used. This weld was listed previously as 2-53A-8-13 on iso 2-53A-8(1) until it was transferred to iso 2LP-189.

Pipe to Elbow 02.C5.11.0033 C05.011.033, C05.01 1.033A 2LP-189-13 53A 2LP-189 PDI-UT-2 UT SS 1.000 / 10.000 Component Procedure NDE-600 uses the component for O-ISIN4-102A-2.2 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is Circumferential Class 2 used, then the calibration block listed shall be used. This weld was listed previously as 2-53A-8-13 on iso 2-53A-8(1) until it was transferred to iso 2LP-189.

Pipe to Elbow 02.C5.11.0034 C05.011.034, C05.011.034A 2LP-189-14 53A 2LP-189 NDE-35 PT SS 1.000 / 10.000 Procedure NDE-600 uses the component for Circumferential Class 2 O-ISIN4-102A-2.2 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used. This weld was listed previously as 2-53A-8-14 on iso 2-53A-8(1) until it was transferred to iso 2LP-189.

Pipe to Elbow O2.C5.111.0034 C05.011.034, C05.011.034A 2LP-189-14 53A 2LP-189 PDI-UT-2 UT SS 1.000 / 10.000 Component Procedure NDE-600 uses the component for O-ISIN4-102A-2.2 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is Circumferential Class 2 used, then the calibration block listed shall be used. This weld was listed previously as 2-53A-Printed 02/16/09 Ick83 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 47 of 71

Oconee 2, 4th IntervAtage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched ThicklDia Cal Blocks Comments / HistoricalData Cateaor C-F-1 8-14 on iso 2-53A-8(1) until it was transferred to iso 2LP-189.

Pipe to Elbow 02.C5.11.0035 C05.01 1.035, C05.011.035A 2LP-215-1 53A 2LP-215 NDE-35 PT SS 1.000 / 10.000 Procedure NDE-600 uses the component for Circumferential Class 2 O-ISIN4-102A-2.3 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Elbow to Pipe 02.C5.11.0035 C05.011.035, C05.011.035A 2LP-215-1 53A 2LP-215 PDI-UT-2 UT SS 1.000 / 10.000 Component Procedure NDE-600 uses the component for O-ISIN4-102A-2.3 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is Circumferential Class 2 used, then the calibration block listed shall be used.

Elbow to Pipe 02.C5.11.0036 C05.011.036, COS5l 11.036A 2LP-215-17 53A 2LP-215 NDE-35 PT SS 1.000 / 10.000 Procedure NDE-600 uses the component for Circumferential Class 2 O-ISIN4-102A-2.3 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Flow Restrictor 02.C5.11.0036 C05.011.036, C05.011.036A 2LP-215-17 53A 2LP-215 NDE-600 UT SS 1.000 / 10.000 Component Procedure NDE-600 uses the component for O-ISIN4-102A-2.3 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is Circumferential Class 2 used, then the calibration block listed shall be used.

Pipe to Flow Restrictor Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 48 of 71

Oconee 2, 4th Intervltage 3 (EOC-23)

Summary Num Jnsp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor C-F-1 02.C5.11.0067 C05.011.067, C05.011.067A 2LP-218-23 53A 2LP-218 NDE-35 PT SS 1.000 / 10.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-102A-2.3 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Valve 2LP-1 76 02.C5.11.0067 C05.011.067, C05.011.067A 2LP-218-23 53A 2LP-218 PDI-UT-2 UT SS 1.000 / 10.000 Component Procedure NDE-600 uses the component for 0-ISIN4-102A-2.3 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used Circumferential Class 2 in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Valve 2LP-176 02.C5.11.0071 C05.011.071, C05.011.071A 2LPS-724-10 I 14B 2LPS-724 NDE-35 PT SS 0.432 / 6.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-124B-2.2 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Elbow to Pipe 02.C5.11.0071 C05.011.071, C05.011.071A 2LPS-724-1 0 14B 2LPS-724 PDI-UT-2 UT SS 0.432 / 6.000 Component Procedure NDE-600 uses the component for 0-ISIN4-124B-2.2 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is Circumferential Class 2 used, then the calibration block listed shall be used.

Elbow to Pipe 02.C5.1 1.0071 C05.011.071, C05.011.071A 2LPS-724-10 14B 2LPS-724 NDE-600 UT SS 0.432 / 6.000 Component Procedure NDE-600 uses the component for 0-ISIN4-124B-2.2 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is Circumferential Class 2 used, then the calibration block listed shall be used.

Elbow to Pipe Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 49 of 71

Oconee 2, 4th IntervOtage3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments /Historical Data Catepor C-F-1 C05.011.076, 02.C5.11.0076 C05.011.076A 2LPS-724-18 14B 2LPS-724 NDE-35 PT SS 0.432 / 6.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-124B-2.2 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.11.0076 C05.011.076, C05.011.076A 2LPS-724-18 14B 2LPS-724 PDI-UT-2 UT SS 0.432 / 6.000 - Component Procedure NDE-600 uses the component for O-ISIN4-124B-2.2 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used Circumferential Class 2 in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.11.0079 C05.011.079, C05.011.079A 2LPS-724-8 14B 2LPS-724 NDE-35 PT SS 0.432 / 6.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-124B-2.2 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.11.0079 C05.011.079, 005.011.079A 2LPS-724-8 14B 2LPS-724 PDI-UT-2 UT SS 0.432 / 6.000 Component Procedure NDE-600 uses the component for 0-ISIN4-124B-2.2 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used Circumferential Class 2 in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Elbow C05.011.080, 02.C5.11.0080 C05.011.080A 2LPS-724-9 14B 2LPS-724 NDE-35 PT SS 0.432 / 6.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-124B-2.2 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Elbow to Pipe 02.C5.11.0080 C05.011.080, C05.011.080A Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 50 of 71

4 Oconee 2, 4th Interv tage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor C-F-1 2LPS-724-9 14B 2LPS-724 PDI-UT-2 UT SS 0.432 / 6.000 Component Procedure NDE-600 uses the component for O-ISIN4-124B-2.2 PDI-UT-2-O calibration. Procedure PDI-UT-2 may be used Class 2 in lieu of procedure NDE-600. If PDI-UT-2 is Circumferential used, then the calibration block listed shall be used.

Elbow to Pipe 02.C5.21.0004 C05.021.004, C05.021.004A 2-RCP-FTR2B-SH-2 51A 2-51A-28(1) NDE-12 RT SS 0.531 / 4.000 Reactor Coolant Pump Seal Supply Filter 2B.

Circumferential Class 2 OM-201-0473 Pc. 10 to Pc. 1. -- (C05.021.004) Remove filter from housing to insure the system is drained O-ISIN4-101A-2.4 prior to performing RT.

Terminal End Filter Hub to Filter Housing 02.C5.21.0027 C05.021.035, C05.021.035A 2-51A-28-15 51A 2-51A-28(1) NDE-35 PT SS 0.531 / 4.000 Procedure NDE-600 uses the component for Circumferential Class 2 O-ISlN4-101A-2.4 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Flange 02.C5.21.0027 C05.021.035, C05.021.035A 2-51A-28-15 51A 2-51A-28(1) PDI-UT-2 UT SS 0.531 / 4.000 Component Procedure NDE-600 uses the component for O-ISIN4-101A-2.4 50307 calibration. Procedure PDI-UT-2 may be used PDI-UT-2-O in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be Circumferential Class 2 used.

Pipe to Flange 02.C5.21.0028 C05.021 .036, C05.021 .036A 2-51A-28-17 51A 2-51A-28(1) NDE-35 PT SS 0.531 / 4.000 Procedure NDE-600 uses the component for Circumferential Class 2 O-ISIN4-101A-2.4 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Tee to Pipe 02.C5.21.0028 C05.021.036, C05.021.036A 2-51A-28-17 51A 2-51A-28(1) PDI-UT-2 UT Ss 0.531 / 4.000 Component Procedure NDE-600 uses the component for O-ISIN4-101A-2.4 50307 calibration. Procedure PDI-UT-2 may be used PDI-UT-2-O in lieu of procedure NDE-600. If PDI-UT-2 is Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 51 of 71

Oconee 2, 4th Jnterv*.tage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Catego' C-F-1 Circumferential Class 2 used, then the calibration block listed shall be used.

Tee to Pipe 02.C5.21.0029 C05.021.037, C05.021.037A 2-51A-28-21 51A 2-51A-28(1) NDE-35 PT SS 0.531 / 4.000 Procedure NDE-600 uses the component for Circumferential Class 2 O-ISIN4-101A-2.4 calibration. Procedure PDI-UT-2 may be used inlieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Pipe to Valve 2HP-135 02.C5.21.0029 C05.021.037, C05.021.037A 2-51A-28-21 51A 2-51A-28(1) PDI-UT-2 UT SS 0.531 / 4.000 Component Procedure NDE-600 uses the component for O-ISIN4-1O1A-2.4 50307 calibration. Procedure PDI-UT-2 may be used PDI-UT-2-O in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be

  • Circumferential Class 2 used.

Pipe to Val ve 2HP-135 02.C5.211.0030 C05.021.038, C05.021.038A 2-51A-28-23 51A 2-51A-28 (1) NDE-35 PT SS 0.531 / 4.000 Procedure NDE-600 uses the component for Circumferential Class 2 O-ISIN4-101A-2.4 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Tee to Elbow 02.C5.21.0030 C05.021.038, C05.021.038A 2-51A-28-23 51A 2-51A-28(1) PDI-UT-2 UT SS 0.531 / 4.000 Component Procedure NDE-600 uses the component for O-ISIN4-101A-2.4 50307 calibration. Procedure PDI-UT-2 may be used PDI-UT-2-O in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be Circumferential Class 2 used.

Tee to Elbow 02.C5.21.0031 C05.021.039, C05.021.039A 2HP-222-2 51A 2HP-222 NDE-35 PT SS 0.674 / 4.000 Procedure NDE-600 uses the component for Circumferential Class 2 O-ISIN4-101A-2.4 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Valve 2HP-26 to Elbow Printed 02/16/09 1ck8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 52 of 71

0 Summary Num Oconee 2, 4th lntervatage 3 (EOC-23)

Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor C-F-I 02.C5.21.0031 C05.021.039, C05.021.039A 2HP-222-2 51A 2HP-222 PDI-UT-2 UT SS 0.674 / 4.000 Component Procedure NDE-600 uses the component for O-ISIN4-101A-2.4 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is Circumferential Class 2 used, then the calibration block listed shall be used.

Valve 2HP-26 to Elbow 02.C5.21.0032 C05.021.040, C05.021.040A 2HP-222-104 51A 2HP-222 NDE-35 PT SS 0.674 / 4.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-101A-2.4 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used. This weld was listed previously as 2-51A-28-104 until iso 2-51A-28(2) was deleted and this weld was transferred to iso 2HP-222.

Elbow to Pipe 02.C5.21.0032 C05.021.040, C05.021.040A 2HP-222-104 51A 2HP-222 PDI-UT-2 UT SS 0.674 / 4.000 Component Procedure NDE-600 uses the component for 0-ISIN4-101A-2.4 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is Circumferential Class 2 used, then the calibration block listed shall be used. This weld was listed previously as 2-51A-28-104 until iso 2-51A-28(2) was deleted and this weld was transferred to iso 2HP-222.

Elbow to Pipe 02.C5.21.0055 C05.021.065, C05.021.065A 2-51A-17-93 51A 2-51A-17(2) NDE-35 PT SS 0.375 / 2.500 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-101A-2.3 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is used, then the calibration block listed shall be used.

Tee to Pipe 02.C5.21.0055 C05.021.065, C05.021.065A 2-51A-17-93 51A 2-51A-17(2) NDE-600 UT SS 0.375 / 2.500 Component Procedure NDE-600 uses the component for 0-ISIN4-101A-2.3 PDI-UT-2-0 calibration. Procedure PDI-UT-2 may be used in lieu of procedure NDE-600. If PDI-UT-2 is Circumferential Class 2 used, then the calibration block listed shall be used.

Tee to Pipe Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat °'C" Oconee 2 2/16/2009 10:32:23 AM Page 53 of 71

Oconee 2, 4th Intervltage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / Historical Data Categorv C-F-1 02.C5.21.0256 C05.021.

2HP-221-22 51A 2HP-221 NDE-35 PT SS 0.531 / 4.000 This weld was listed previously as 2-51A-128-Circumferential Class 2 0-ISIN4-101A-2.4 18 until iso 2-51A-128 was redrawn.

Valve 2HP-410 to Elbow 02.C5.21.0256 C05.021.

2HP-221-22 51A 2HP-221 NDE-600 UT SS 0.531 / 4.000 Component This weld was listed previously as 2-51A-128-Circumferential Class 2 O-ISIN4-101A-2.4 18 until iso 2-51A-128 was redrawn.

Valve 2HP-410 to Elbow 02.C5.30.0003 C05.030.003 2-51 B-23-67 51B 2-51B-23 NDE-35 PT SS 0.154 / 2.000 Socket Class 2 0-ISIN4-101A-2.2 Tee to Pipe Cate-gorv C-F-2 02.C5.51.0002 C05.051 .002, C05.051.002A 2-01 A-4-29 01A 2-01A-4(2) NDE-25 MT CS 1.250 / 36.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-122A-2.1 calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.51.0002 C05.051.002, C05.051.002A 2-01 A-4-29 01A 2-01A-4(2) PDI-UT-1 UT CS 1.250 / 36.000 Component Procedure NDE-600 uses the component for 0-ISIN4-122A-2.1 PDI-UT-1-0 calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is Circumferential Class 2 used, then the calibration block listed shall be used.

Pipe to Elbow 02.C5.51.0004 C05.051.004, C05.051.004A 2MS-124-71V 01A 2MS-124 NDE-25 MT CS 0.875 / 26.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISlN4-122A-2.1 calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Pipe to Reducer Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 54 of 71

0 Oconee 2, 4th Interv-0tage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor C-F-2 02.05.51 .0004 C05.051.004, C05.051.004A 2MS-124-71V 01A 2MS-124 PDI-UT-1 UT CS 0.875 / 26.000 Component Procedure NDE-600 uses the component for 0-ISIN4-122A-2.1 PDI-UT-1-0 calibration. Procedure PDI-UT-i may be used Circumferential Class 2 in lieu of procedure NDE-600. If PC0-UT-1 is used, then the calibration block listed shall be used.

Pipe toReducer _________________

02.C5.51.0011 C05.051.01i1, C05.051 .01 1lA 2-MSB10-E 01A 2MS-111 NDE-25 MT CS 0.562 / 12.000 Subassembly 2MSB-10.

Circumferential Class 2 0-ISIN4-122A-2.2 This subassembly used to be shown on 2MSB-10 isometric 2-01A-15 until the subassembly was transferred to 2MS-1 11 .Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Elbow to Pipe 02.C5.51.0011 C05.051.011, C05.051.01 1A 2-MSB10-E 01A 2MS-111 PDI-UT-1 UT CS 0.562 /12.000 Component Subassembly 2MSB-10.

0-ISIN4-122A-2.2 PDI-UT-1-0 This subassembly used to be shown on Circumferential Class 2 isometric 2-01A-15 until the subassembly was 2MSB-10 transferred to 2MS-111I.Procedure NDE-600 uses the component for calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Elbow to Pipe 02.C5.51.0025 C05.051.025, C05.051.025A 2MS-1 32-54 01A 2MS-132 NDE-25 MT CS 0.500 / 8.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-122A-2.3 calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Elbow to Pipe 02.C5.51.0025 C05.051.025, C05.051.025A 2MS-132-54 01A 2MS-132 NDE-600 UT CS 0.500 / 8.000 Component Procedure NDE-600 uses the component for 0-ISIN4-122A-2.3 PDI-UT-1-0 calibration. Procedure PDI-UT-1 may be used Circumferential in lieu of procedure NDE-600. If PDI-UT-1 is Class 2 used, then the calibration block listed shall be used.

Printed 02/16/09 Ick8302 v. 01 /19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 55 of 71

Oconee 2, 4th Intervitage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Cate-gory C-F-2 02.C5.51 .0031 C05.051.031, C05.051.031A 2-144B-49-136 14B 2-14B-49 NDE-25 MT CS 0.500 / 8.000 Flange at valve 2LPSW-18. Procedure NDE-Circumferential Class 2 0-ISIN4-124B-2.2 600 uses the component for calibration.

Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Flange to Pipe 02.C5.51.0031 C05.051.031, C05.051.031A 2-141-49-136 14B 2-141-49 PDI-UT-1 UT CS 0.500 /8.000 Component Flange at valve 2LPSW-18. Procedure NDE-0-ISIN4-124B-2.2 PDI-UT-1-0 600 uses the component for calibration.

Circumferential Class 2 Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Flange to Pipe 02.C5.51.0032 C05.051.032, C05.051.032A 2MS-1 36-209 01A 2MS-136 NDE-25 MT CS 0.432 / 6.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-122A-2.2 calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Pipe to Valve 2MS-24 02.C5.51.0032 C05.051.032, C05.051.032A 2MS-136-209 01A 2MS-136 PDI-UT-1 UT CS 0.432./ 6.000 Component Procedure NDE-600 uses the component for 0-ISIN4-122A-2.2 PDI-UT-1-0 calibration. Procedure PDI-UT-1 may be used Circumferential Class 2 in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Pipe to Valve 2MS-24 02.C5.51.0033 C05.051.033, C05.051.033A 2-148-50-111 14B 2-14B-50 NDE-25 MT CS 0.500 / 8.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-124B-2.2 calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Elbow to Pipe 02.C5.51.00 33 C05.051.033, C05.051.033A Printed 02/16/09ick8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 56 of 71

9 Summary Num Oconee 2, 4th Interveitage3 (EOC-23)

Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Catecor C-F-2 2-14B-50-1 11 14B 2-14B-50 PDI-UT-1 UT CS 0.500 / 8.000 Component Procedure NDE-600 uses the component for 0-ISIN4-124B-2.2 PDI-UT-1-O calibration. Procedure PDI-UT-1 may be used Circumferential Class 2 in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used.

Elbow to Pipe 02.C5.51.0034 C05.051.034, C05.051.034A 2LPS-606-4 14B 2LPS-606 NDE-25 MT CS 0.500 / 8.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-124B-2.2 calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used. This weld was listed previously as 2-14B-51-4 until iso 2-141-51 was redrawn.

Pipe to Elbow 02.C5.51.0034 C05-051.034, C05.051.034A 2LPS-606-4 14B 2LPS-606 PDI-UT-1 UT CS 0.500 / 8.000 Component Procedure NDE-600 uses the component for 0-ISIN4-124B-2.2 PDI-UT-1-0 calibration. Procedure PDI-UT-1 may be used Circumferential Class 2 in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used. This weld was listed previously as 2-14B-51-4 until iso 2-14B-51 was redrawn.

Pipe to Elbow 02.C5.51.0037 C05.051.037, C05.051.037A 2MS-136-9A 01A 2MS-136 NDE-25 MT CS 0.432 / 6.000 Procedure NDE-600 uses the component for Circumferential Class 2 0-ISIN4-122A-2.2 calibration. Procedure PDI-UT-1 may be used in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used. This weld was listed previously as 2-01A-16-9A on iso 2-01A-16 until it was transferred to iso 2MS-136.

Pipe to Elbow 02.C5.51.0037 C05.051.037, C05.051.037A 2MS-136-9A 01A 2MS-136 PDI-UT-1 UT CS 0.432 / 6.000 Component Procedure NDE-600 uses the component for 0-ISIN4-122A-2.2 PDI-UT-1-0 calibration. Procedure PDI-UT-1 may be used Circumferential Class 2 in lieu of procedure NDE-600. If PDI-UT-1 is used, then the calibration block listed shall be used. This weld was listed previously as 2-01A-16-9A on iso 2-01A-16 until it was transferred to iso 2MS-136.

SDi- Cnaetn ElhL .... e.. 2 2/600 12 AM ag5o7 Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 22/16/2009 10:32:23 AM Page 57 of 71

Oconee 2, 4th Interv"Stage 3 (EOC-23)

Summary Num Insp Component ID /Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Category C-F-2 02.C5.61 .0001 C05.061.001, C05.061.001A 2SGA-W250-4 03A OM 201.S--0157.001 NDE-25 MT CS 0.300 / 3.000 A Steam Generator (Auxiliary Feedwater Circumferential Class 2 OM 201.S--0022.001 Header)

OM 201.S--0147.001 O-ISIN4-121B-2.3 OM 201 .S--0048.001 This weld is located on riser piping associated with weld W254 (2SGA-W254).

The ID was determined from drawing OM 1201.S--0005. It is weld 250 and part number (5205000) 4. We combined the 2 and the weld ID is 2SGA-W250-4.

Either Liquid Penetrant or Magnetic Particle are acceptable methods to satisfy the surface examination requirements. A combination of Liquid Penetrant and Magnetic Particle may be used to achieve 100% of the required coverage if necessary.

Elbow to Nozzle/Flange 02.C5.61.0001 C05.061.001, C05.061.001A 2SGA-W250-4 03A OM 201.S--0157.001 NDE-12 RT CS 0.300 / 3.000 A Steam Generator (Auxiliary Feedwater Circumferential Class 2 OM 201.S--0022.001 Header)

OM 201 .S--0147.001 O-ISIN4-121 B-2.3 OM 201 .S--0048.001 This weld is located on riser piping associated with weld W254 (2SGA-W254).

The ID was determined from drawing OM 1201 .S--0005. It is weld 250 and part number (5205000) 4. We combined the 2 and the weld ID is 2SGA-W250-4.

Either Liquid Penetrant or Magnetic Particle are acceptable methods to satisfy the surface examination requirements. A combination of Liquid Penetrant and Magnetic Particle may be used to achieve 100% of the required coverage if necessary.

Elbow to Nozzle/Flange Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 58 of 71

0 Summary Num Oconee 2, 4th Interv*tage3 (EOC-23)

Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Cate-gory C-F-2 02.C5.61.0002 C05.061.002, C05.061.002A 2SGA-W251-4 03A OM 201.S--0157.001 NDE-12 RT CS 0.300 / 3.000 A Steam Generator (Auxiliary Feedwater Circumferential Class 2 OM 201.S--0022.001 Header)

OM 201 .S--0147.001 0-ISIN4-121B-2.3 OM 201 .S--0048.001 This weld is located on riser piping associated with weld W254 (2SGA-W254).

The ID was determined from drawing OM 1201.S--0005. It is weld W-251 and part number (5204849) 4. we combined the 2 and the weld ID is 2SGA-W251-4.

Either Liquid Penetrant or Magnetic Particle are acceptable methods to satisfy the surface examination requirements. A combination of Liquid Penetrant and Magnetic Particle may be used to achieve 100% of the required coverage if necessary.

Pipe to Elbow 02.C5.61.0002 C05.061.002, C05.061.002A 2SGA-W251-4 03A OM 201.S--0157.001 NDE-25 MT CS 0.300 / 3.000 A Steam Generator (Auxiliary Feedwater Circumferential Class 2 OM 201.S--0022.001 Header)

O-ISIN4-121B-2.3 OM 201 .S--0147.001 OM 201 .S--0048.001 This weld is located on riser piping associated with weld W254 (2SGA-W254).

The ID was determined from drawing OM 1201 .S--0005. It is weld W-251 and part number (5204849) 4. we combined the 2 and the weld ID is 2SGA-W251-4.

Either Liquid Penetrant or Magnetic Particle are acceptable methods to satisfy the surface examination requirements. A combination of Liquid Penetrant and Magnetic Particle may be used to achieve 100% of the required coverage if necessary.

Pipe to Elbow Printed 02/16/09 lck8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 59 of 71

9 Summary Num Oconee 2, 4th Intervltage Insp 3 (EOC-23)

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched ThickWDia Cal Blocks Comments / HistoricalData Catepor C-F-2 02.C5.61.0036 C05.061.

2SGA-W335 03A OM 201.S--0157.001 NDE-12 RT CS 0.300 / 3.000 A Steam Generator (Auxiliary Feedwater Circumferential Class 2 OM 201.S--0022.001 Header)

O-ISIN4-121B-2.3 OM 201 .S--0002.001 Either Liquid Penetrant or Magnetic Particle are acceptable methods to satisfy the surface examination requirements. A combination of Liquid Penetrant and Magnetic Particle may be used to achieve 100% of the required coverage if necessary.

This weld is located on riser piping associated with weld W254 (2SGA-W254).

The ID was determined from drawing OM 1201 .S--0005. The locations for W333 thru W338 are not in the order as shown on drawing OM-201.S--0157. We used Om 201.S--

0022 to determine the order of welds W254 thru W259. Then we used OM 201 .S--0005 to determine the order of welds W333 thru W338.

02.C5.61.0036 C05.061.

2SGA-W335 03A OM 201.S--0157.001 NDE-25 MT CS 0.300 / 3.000 A Steam Generator (Auxiliary Feedwater Circumferential Class 2 OM 201.S--0022.001 Header)

O-ISIN4-121B-2.3 OM 201 .S--0002.001 Either Liquid Penetrant or Magnetic Particle are acceptable methods to satisfy the surface examination requirements. A combination of Liquid Penetrant and Magnetic Particle may be used to achieve 100% of the required coverage if necessary.

This weld is located on riser piping associated with weld W254 (2SGA-W254).

The ID was determined from drawing OM 1201 .S--0005. The locations for W333 thru W338 are not in the order as shown on drawing OM-201.S--0157. We used Om 201.S--

0022 to determine the order of welds W254 thru W259. Then we used OM 201 .S--0005 to determine the order of welds W333 thru W338.

02.C5.70.0002 C05.070.002 2-03A-1 0-57 03A 2-03A-10 NDE-35 PT CS 0.344 / 2.000 Socket Class 2 O-ISIN4-121D-2.1 Pipe to Half Coupling Printed 02/16/091ck8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/200910:32:23 AM Page 60 of 71

0 Summary Num Oconee 2, 4th Intervitage Insp 3 (EOC-23)

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Cateaor C-F-2 02.C5.70.0003 C05.070.003 2-03A-1 0-58 03A 2-03A-10 NDE-35 PT CS 0.344 / 2.000 Socket Class 2 0-ISIN4-121B-2.5 Pipe to Valve 2FDW-301 02.C5.81.0004 C05.081.004 2-FWD63-B 03 2FDW-226 NDE-25 MT CS 1.031 /20.000 This branch connection weld is covered by a Branch Class 2 0-ISIN4-121B-2.3 reinforcing plate weld. The examination 2FWD-63 requirements will be as shown by Figure IWC-2500-13.

Subassembly 2FWD-63.

Pipe to Pipe 02.C5.81.0005 C05.081.005 2-03A-1 0-56 03A 2-03A-10 NDE-35 PT CS 0.344 / 2.000 Branch Class 2 0-ISIN4-121D-2.1 Half Coupling to Pipe Categor D-A 02.D1.20.0001 D01.020.001 2-01A-4-0-1400H-DJB1004 01A 2-01-06/sht.2 NDE-65 VT-1 NA 0.216 / 6.000 Calculation No. OSC-445. Inspect with Rigid Support Class 3 0-ISIN4-122A-2.4 F01.030.002.

02.D1.20.0003 D01.020.003 2-01A-4-2-0-1400A-R27 01A 2-01-06/sht.2 NDE-65 VT-1 NA 0.237 /6.000 Calculation No. OSC-445. Inspect with Mech Snubber Class 3 0-ISIN4-122A-2.4 F01.032.002.

02.D1.20.0024 001.020.067 2-14B-1-0-1439B-H1-8 14B 4-14-04/sht.3 NDE-65 VT-1 NA 0.625 / 8.000 Calculation No. OSC-474. Inspect with Spring Hgr Class 3 O-ISIN4-124B-2.2 F01.032.052.

D01.020.067 02.D1.20.0092 D01.020.

2-14B-0-1439A-H34 14B 2-14-06/sht.2 NDE-65 VT-1 1.000 / 14.000 Calculation No. OSC-475.

Rigid Restraint Class 3 0-ISIN4-124B-2.2 Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 61 of 71

Summary Num Oconee 2, 4th Intervltage Insp 3 (EOC-23) 0 Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments /Historical Data Catego ELC H02.001.009 02.H2.1.0009 2-PIB1-12 50 ISI-OCN2-009 NDE-35 PT CS-Inconel 2.250 / 8.750 RTE-Mounting Boss Pc.58 to Pipe Pc.56. The Circumferential Class I OM-1201-1521 diameter of hole that penetrates the nozzle into the RCP 211 Suction Piping = .613. Reference Section 7 of the ISI Plan, General Requirements.

Dissimilar Nozzle to Pipe 02.H2.1.0010 H02.001.010 2-PIB2-12 50 ISI-OCN2-010 NDE-35. PT CS-Inconel 2.250 / 8.750 RTE Mounting Boss Pc.58 to Pipe Pc.56. The Circumferential Class 1 OM-1201-1521 diameter of hole that penetrates the nozzle into the RCP 2B2 Suction Piping = .613. Reference Section 7 of the ISI Plan, General Requirements.

Dissimilar Nozzle to Pipe 02.H3.1.0007 H03.001.007 2-03-18-25 03 2-03-18 (1) PDI-UT-1 UT CS 1.219 / 24.000 Component Procedure NDE-600 should be used for angle O-ISIN4-121B-2.3 PDI-UT-1-O beam inspection and Procedure NDE-946 Circumferential Class 3 should be used for thickness measurements on this weld.

PDI-UT -1 may be used in lieu of NDE-600 with cal block PDI-UT-1-0.

Inspection results should be forwarded to Timothy D. Brown of the Oconee Design Basis Group.

Pipe to Elbow 02.H3.1.0008 H03.001.008 2-03-18-25G 03 2-03-18 (1) PDI-UT-1 UT CS 1.219 / 24.000 Component Weld 2-03-18-25 is a Pipe to elbow weld O-ISIN4-121B-2.3 PDI-UT-1-0 located on iso 2-03-18(1). Weld 2-03-18-25G Circumferential Class 3 is a Grinnell Subassembly (elbow to pipe) weld located on the opposite end of the elbow from weld 1-03-18-25 Procedure NDE-600 should be used for angle beam inspection and Procedure NDE-946 should be used for thickness measurements on this weld.

PDI-UT -1 may be used in lieu of NDE-600 with cal block PDI-UT-1-O.

Inspection results should be forwarded to Timothy D. Brown of the Oconee Design Basis Group.

Elbow to Pipe Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 62 of 71

9 Summary Num Oconee 2, 4th Intervitage Insp 3 (EOC-23)

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Cateoor ELC 02.H3.1.0009 H03.001.009 2-03-18-43A 03 2-03-18 (2) NDE-600 UT CS 1.219 / 24.000 Component Procedure NDE-600 should be used for angle Circumferential Class 2 O-ISIN4-121B-2.3 beam inspection and Procedure NDE-946 should be used for thickness measurements on this weld.

Inspection results should be forwarded to Timothy D. Brown of the Oconee Design Basis Group.

Pipe to Elbow 02.H3.1.0010 H03.001.010 2-FW D60-A 03 2-03-18 (2) NDE-600 UT CS 1.219/ 24.000 Component Weld 2-03-18-43AA is a Pipe to elbow weld Circumferential Class 2 O-ISIN4-121B-2.3 located on iso 2-03-18(2). Weld 2-FWD60-A is a Grinnell Subassembly (elbow to pipe) weld located on the opposite end of the elbow from weld 1-03-18-43AA.

Procedure NDE-600 should be used for angle beam inspection and Procedure NDE-946 should be used for thickness measurements on this weld.

Inspection results should be forwarded to Timothy D. Brown of the Oconee Design Basis Group.

Elbow to Pipe 02.H3.11.0011 H03.001.011 2-03-18-43AA 03 2-03-18 (2) NDE-600 UT CS 1.219 / 24.000 Component Procedure NDE-600 should be used for angle Circumferential Class 2 O-ISIN4-121B-2.3 beam inspection and Procedure NDE-946 should be used for thickness measurements on this weld.

Inspection results should be forwarded to Timothy D. Brown of the Oconee Design Basis Group.

Pipe to Elbow 02.H4.1.0009 H04.001.009 2-03-0-1401A-R1 1 03 2-03-01/sht.1 NDE-66 VT-3 NA 0.000 / 24.000 Calculation No. OSC-454.

Rigid Support Class 3 O-ISIN4-121B-2.3 Printed 02/16/09]ck8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 63 of 71

0 Oconee 2, 4th Intervmtage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor ELC 02.1-4.1.0010 H04.001.010, H04.001.010A 2-03-0-5511-H49 03 2-03-01/sht.1 NDE-25 MT CS 1.500 / 24.000 Calculation No. OSC-454.

Rigid Support Class 3 O-ISIN4-121B-2.3 -- (H04.001.010A) Perform a Surface exam on the attachment welds.

Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.

02.1-4.1 .0010 H04.001.010, H04.001.010A 2-03-0-5511-H49 03 2-03-01/sht.1 NDE-66 VT-3 CS 1.500 / 24.000 Calculation No. OSC-454.

Rigid Support Class 3 O-ISIN4-121B-2.3 -- (H04.001.010A) Perform a Surface exam on the attachment welds.

Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.

02.H4.1.0011 H04.001.011, H04.001.01 1A 2-03-0-5511-H48 03 2-03-01/sht.1 NDE-25 MT CS 0.322 / 24.000 Calculation No. OSC-454.

Spring Hgr Class 3 O-ISIN4-121B-2.3 -- (H04.001.011A) Perform a Surface exam on the attachment welds.

Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.

02.H4.1.0011 H04.001.011, H04.001.01 1A 2-03-0-551-H48 03 2-03-01/sht.1 NDE-66 VT-3 CS 0.322 / 24.000 Calculation No. OSC-454.

Spring Hgr Class 3 O-ISlN4-121B-2.3 -- (H04.001.011A) Perform a Surface exam on the attachment welds.

Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.

02.H4.1.0012 H04.001.012, H04.001.012A 2-03-0-1439A-H63 03 2-03-01/sht.1 NDE-35 PT CS 0.500 / 24.000 Calculation No. OSC-454.

Spring Hgr Class 3 O-ISIN4-121B-2.3 -- (H04.001.012A) Perform a Surface exam on the attachment welds.

Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.

Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 64 of 71

0 Summary Num Oconee 2, 4th Intervltage Insp 3 (EOC-23)

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor ELC 02.H4.1.0012 H04.001.012, H04.001.012A 2-03-0-1439A-H63 03 2-03-01/sht.1 NDE-66 VT-3 CS 0.500 / 24.000 Calculation No. OSC-454.

Spring Hgr Class 3 O-ISIN4-121B-2.3 -- (H04.001.012A) Perform a Surface exam on the attachment welds.

Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.

02.1-4.1 .0013 H04.001.013, H04.001.013A 2-03-0-1439A-H61 03 2-03-01/sht.1 NDE-35 PT CS 0.500 / 24.000 Calculation No. OSC-454.

Spring Hgr Class 3 O-ISIN4-121B-2.3 -- (H04.001.013A) Perform a Surface exam on the attachment welds.

Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.

02.H4.1.0013 H04.001 .013, H04.001 .01 3A 2-03-0-1439A-H61 03 2-03-01/sht.1 NDE-66 VT-3 CS 0.500 / 24.000 Calculation No. OSC-454.

Spring Hgr Class 3 O-ISIN4-121B-2.3 -- (H04.001 .01 3A) Perform a Surface exam on the attachment welds.

Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.

02.H4.1.0014 H04.001 .014, H04.001 .01 4A 2-03-0-551--H60 03 2-03-01/sht.1 NDE-25 MT CS 0.500 / 24.000 Calculation No. OSC-454.

Rigid Support Class 3 O-ISIN4-121B-2.3 -- (H04.001.014A) Perform a Surface exam on the attachment welds.

Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.

02.H4.1.0014 H04.001.014, H04.001.014A 2-03-0-5511-H60 03 2-03-01/sht.1 NDE-66 VT-3 CS 0.500 / 24.000 Calculation No. OSC-454.

Rigid Support Class 3 O-ISIN4-121B-2.3 -- (H04.001.014A) Perform a Surface exam on the attachment welds.

Note: Magnetic Particle examinations (with the use of procedure NDE-25) may be performed on carbon steel material in lieu of or in conjunction with liquid penetrant examinations.

Printed 02/16/091ck8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 65 of 71

0 Summary Num Oconee 2, 4th Intervotage 3 (EOC-23)

Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Cateaor ELC 02.H4.1.0029 H04.001 .029 2-01A-0-1401B-H7 01A 2-01-01/sht.2 NDE-66 VT-3 NA 0.000 / 36.000 Calculation No. OSC-440.

Spring Hgr Class 2 O-ISIN4-122A-2.1 Inspect with item number FO1.022.007.

Categor F-A 02.F1.10.0004 FOl1.010.014 2-51A-0-1478A-H5C 51A 0-2RB-25112-01 NDE-66 VT-3 NA 0.500 / 2.500 Calculation No. OSC-1660-06.

Rigid Support Class 1 O-ISIN4-101A-2.1 02.F1.11.0003 F01.01 1.013 2-51A-0-1479A-H8A 51A 0-2RB-25315-04 NDE-66 VT-3 NA 0.000 / 2.500 Calculation No. OSC-1324-06.

Rigid Restraint Class 1 O-ISIN4-101A-2.4 HPI East Coolant Loop.

02.F1.11.0004 F01.011.014 2-51A-0-1479A-H78 51A 2-51-24 NDE-66 VT-3 NA 0.312/2.500 Calculation No. OSC-1323. HPI West Coolant Rigid Restraint Class 1 O-ISIN4-101A-2.4 Loop.

02.F1.11.0009 F01.011.034 2-53A-0-1478A-H4A 53A 0-1492C-3(s) NDE-66 VT-3 NA 0.500 / 10.000 Calculation No. OSC-1318.

Rigid Restraint Class 1 O-ISIN4-102A-2.3 2-53-1 3/sht.2 02.F1.12.0003 F01 .01 2.003 2-50-0-1480A-H8 50 0-2RB-25314-01 NDE-66 VT-3 NA 0.000 / 2.500 Calculation No. OSC-1324-06.

Hyd Snubber Class 1 O-ISIN4-100A-2.2 02.F1.12.0010 F01.012.041 2-57-0-1481 A-CEW-H0802 57 0-2RB-25701-01 NDE-66 VT-3 NA 0.000 / 2.500 Calculation No. OSC-1332-06.

Spring Hgr Class 1 O-ISIN4-100A-2.2 02.F1.20.0023 F01.020.051 2-51A-0-1478A-H 1OC 51A 2-51-12/sht.5 NDE-66 VT-3 NA 0.500 /2.500 Calculation No. OSC-1660-06.

Rigid Support Class 2 O-ISIN4-101A-2.1 HPI System. Inspect with C03.020.035.

Printed 02/16/09ick8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 66 of 71

0 Summary Num Oconee 2, 4th Intervitage Insp 3 (EOC-23)

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData CateFor F-A 02.F1.20.0024 F011.020.052 2-51A-0-1439A-H 175 51A 2-51-18/sht.1 NDE-66 VT-3 NA 0.000 / 4.000 Calculation No. OSC-1023.

Rigid Support Class 2 O-ISIN4-101A-2.4 02.F1.20.0029 F01.020.057 2-51A-2-0-437B-H7 51A 2-51-18/sht.6 NDE-66 VT-3 NA 0.000 / 4.000 Calculation No. OSC-1023. HPI System.

Rigid Support Class 2 O-ISIN4-101A-2.4 02.F1.20.0030 F01.020.058 2-51A-3-0-437B-H6 51A 2-51-18/sht.6 NDE-66 VT-3 NA 0.000 / 4.000 Calculation No. OSC-1023.

Rigid Support Class 2 O-ISfN4-101A-2.4 HPI System.

02.F1.20.0032 F01.020.060 2-51 B-2-0-436E-H55 518 0-2AB-25101-03 NDE-66 VT-3 NA 0.000 /4.000 Calculation No. OSC-479.

Rigid Support Class 2 O-ISIN4-101A-2.1 02.F1.20.0037 F01.020.075 2-53B-0-1436A-DE054 53B 0-2AB-25301-03 NDE-66 VT-3 NA 0.000 /10.000 Calculation No. OSC-487.

Rigid Support Class 2 O-ISIN4-102A-2.2 02.F1.20.0044 F01.020.082 2-53B-5-0-1439C-H31 53B 0-2AB-25302-01 NDE-66 VT-3 NA 0.500 / 10.000 Calculation No. OSC-493. Inspect with Rigid Support Class 2 O-ISIN4-102A-2.2 C03.020.047.

02.F1.20.0050 F01.020.092 2-54A-3-0-435B-R2 54A 2-54-02/sht.1 NDE-66 VT-3 NA 0.125 / 8.000 Calculation No. OSC-495.

Rigid Support Class 2 O-ISIN4-103A-2.1 02.F1.20.0051 F01.020.093 2-54A-3-0-1439A-H25 54A 2-54-03/sht.1 NDE-66 VT-3 NA 0.000/ 8.000 Calculation No. OSC-496.

Rigid Support Class 2 O-ISIN4-103A-2.1 Printed 02/16/09)ck8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 67 of 71

0 Summary Num Oconee 2, 4th Interv-tage Insp 3 (EOC-23)

Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Catepo' F-A 02.F1.21.0004 F01.021.022 2-14B-0-1479A-H12 14B 0-1492A-5(S) NDE-66 VT-3 NA 0.750 / 6.000 Calculation No. OSC-1325-06. Inspect with Rigid Restraint Class 2 O-ISIN4-124B-2.2 C03.020.023.

2-14-16/sht.1 02.F1.21.0015 F01.021.043 2-51A-1-0-436J-SR116 51A 0-2AB-25102-01 NDE-66 VT-3 NA 0.750 / 4.000 Calculation No. OSC-481. Inspect with Rigid Restraint Class 2 O-ISIN4-101A-2.3 C03.020.033.

02.F1.21.0024 F01.021.052 2-51B-436J-DE012 51B 0-2AB-25102-05 NDE-66 VT-3 NA 0.000 / 2.000 Calculation No. OSC-481.

Rigid Restraint Class 2 O-ISIN4-101A-2.2 02.F1.21.0031 F01.021.065 2-53B-0-1439A-DE048 53B 0-2AB-25305-01 NDE-66 VT-3 NA 1.000 / 10.000 Calculation No. OSC-491.

Rigid Restraint Class 2 O-ISIN4-102A-2.2 02.F1.21.0033 F01.021.067 2-53-0-1478A-H5 53 0-2RB-25310-03 NDE-66 VT-3 NA 0.337/12.000 Calculation No. OSC-1320-06. Inspect with Rigid Restraint Class 2 O-ISIN4-102A-2.1 C03.020.041.

02.F1.22.0007 F01.022.007 2-01A-0-1401B-H7 01A 2-01-01sht.2 NDE-66 VT-3 NA 0.000 / 36.000 Calculation No. OSC-440.

Spring Hgr Class 2 O-ISIN4-122A-2.1 Inspect with item number H04.001.029.

02.F1.22.0010 F01.022.012 2-03-0-1480A-H7A 03 0-1490B-4(S) NDE-66 VT-3 NA 0.237 / 24.000 Calculation No. OSC-1316-06(Vol.B). Inspect Hyd Snubber Class 2 O-ISIN4-121B-2.3 with C03.020.012.

2-03-05/sht.3 02.F1.22.0011 F01.022.014 2-03A-1 480A-H6B 03A 0-2RB-203A13-01 NDE-66 VT-3 NA 0.000 / 6.000 Calculation No. OSC-1224-17.

Spring Hgr Class 2 O-ISIN4-121D-2.1 Printed 02/16/09 Ick8302 v. 01/19/08 SDQA Cat "C'" Oconee 2 2/16/2009 10:32:23 AM Page 68 of 71

Oconee 2, 4th Intervltage 3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Categor F-A 02.F1.22.0016 F01.022.045 2-51A-435B-DKB-1410 51A 0-2AB-25102-02 NDE-66 VT-3 NA 0.000 / 6.000 Calculation No. OSC-481.

Spring Hgr Class 2 O-ISIN4-101A-2.3 02.F1.22.0018 F01.022.052 2-53B-10-0-435B-H2 53B 0-2AB-25301-03 NDE-66 VT-3 NA: 0.216 / 8.000 Calculation No. OSC-487. Inspect with Spring Hgr Class 2 O-ISIN4-102A-2.1 C03.020.043.

02.F1.22.0056 F01.022.

2-01A-0-1401B-H 18 01A 2-01-01/sht.1 NDE-66 VT-3 0.000 / 8.000 Calculation No. OSC-440.

Spring Hgr Class 2 O-ISIN4-122A-2.1 02.F1.30.0002 F01.030.002 2-01A-4-0-1400H-DJB1004 01A 2-01-06/sht.2 NDE-66 VT-3 NA 0.216 / 6.000 Calculation No. OSC-445. Inspect with Rigid Support Class 3 0-ISIN4-122A-2.4 D01.020.001.

02.F1.30.0004 F01.030.011 2-03A-1401A-GC-907 03A 2-03A-06/sht.1 NDE-66 VT-3 NA 0.000 /6.000 Calculation No. OSC-459.

Rigid Support Class 3 0-ISIN4-121D-2.1 02.F1.30.0027 F01.030.044 2-07A-6-0-1402A-R44 07A 2-07-01/sht.1 NDE-66 VT-3 NA 0.000 / 24.000 Calculation No. OSC-467.

Rigid Support Class 3 0-ISIN4-121A-2.7 02.F1.30.0033 F01.030.062 0-13-447A-H7042 13 4-13-03/sht.1 NDE-66 VT-3 NA 0.000 / 12.000 Calculation No. OSC-1224-25.

Rigid Support Class 3 0-ISIN4-133A-2.5 02.F1.30.0034 F01.030.071 0-14-447A-H7020 14 4-14-15/sht.1 NDE-66 VT-3 NA 0.000 / 6.000 Calculation No. OSC-1224-28.

Rigid Support Class 3 O-ISIN4-133A-2.5 Printed 02/16/091ck8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 69 of 71

0 Summary Num Oconee 2, 4th Intervotage3 (EOC-23)

Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Catepo' F-A 02.F1.30.0036 F01 .030.073 2-144B-1 437A-H25 14B 0-2AB-21405-03 NDE-66 VT-3 NA 0.000 / 16.000 Calculation No. OSC-473.

Rigid Support Class 3 O-ISIN4-124B-2.1 02.F1.30.0042 F01 .030.079 2-148-1 1439B-DE 182 14B 4-14-04/sht.3 NDE-66 VT-3 NA 0.000 / 8.000 Calculation No. OSC-474.

Rigid Support Class 3 O-ISIN4-124B-2.2.

02.F1.31.0010 F01.031.019 2-03A-1 1401 B-SRi 1 03A 2-03A-05/sht.6 NDE-66 VT-3 NA 0.000 / 6.000 Calculation No. OSC-447.

Rigid Restraint Class 3 O-ISIN4-121D-2.1 02.F1.31.0014 F01.031.031 2-07A-0-1400A-SR3 07A 2-07-02/sht.1 NDE-66 VT-3 NA 0.000 / 8.000 Calculation No. OSC-466.

Rigid Restraint Class 3 O-ISIN4-121A-2.8 02.F1.31.0018 F01 .031.052 0-13-447A-H7007 13 4-13-03/sht.1 NDE-66 VT-3 NA 0.000 / 8.000 Calculation No. OSC-1224-25.

Rigid Restraint Class 3 O-ISIN4-133A-2.5 02.F1.31.0151 F01.031.

2-14B-0-1439A-H34 14B 2-14-06/sht.2 NDE-66 VT-3 1.000 / 14.000 Calculation No. OSC-475.

Rigid Restraint Class 3 O-ISIN4-124B-2.2 02.F1.32.0001 F01.032.001 2-01A-4-0-1403D-H8 01A 2-01-06/sht.1 NDE-66 VT-3 NA 0.000 /6.000 Calculation No. OSC-445.

Spring Hgr Class 3 O-ISIN4-122A-2.4 02.F1.32.0002 F01.032.002 2-01A-4-2-0-1400A-R27 01A 2-01-06/sht.2 NDE-66 VT-3 NA 0.237 /6.000 Calculation No. OSC-445. Inspect with Mech Snubber Class 3 O-ISIN4-122A-2.4 D01.020.003.

Printed 02/16/091ck8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/1612009 10:32:23 AM Page 70 of 71

Oconee 2, 4th Interv.Jtage3 (EOC-23)

Summary Num Insp Component ID / Type System ISO/DWG Number Procedure Req Mat Sched Thick/Dia Cal Blocks Comments / HistoricalData Cateaor F-A 02.F1.32.0013 F01 .032.052 2-114B-11-0-1439B-H1-8 14B 4-14-04/sht.3 NDE-66 VT-3 NA 0.625 / 8.000 Calculation No. OSC-474. Inspect with Spring Hgr Class 3 0-ISIN4-124B-2.2 D01.020.067.

02.F1.32.0015 F01 .032.062 2-57-0-1481A-H16 57 0-2RB-25701-01 NDE-66 VT-3 NA 0.000 / 6.000 Calculation No. OSC-1332-06.

Hyd Snubber Class 3 0-ISIN4-100A-2.2 02.F1.40.0009 F01.040.009 2-EFDW-MD-PU-A OM-206-0036 NDE-66 VT-3 NA 0.000 / 0.000 Emergency Feedwater Motor Driven Pump 2A Class 3 0-ISIN4-121D-2.1 Support & Pad.

02.F1.40.0011 F01.040.011 2-EFDW-PU-TD OM-206.A-0001 NDE-66 VT-3 NA 0.000 / 0.000 Emergency Feedwater Pump Turbine Driven Class 3 O-ISIN4-121D-2.1 Support & Pad. Class C 02.F1.40.0018 F01.040.018 2-RCSR-COOLER-A OM-201-086 NDE-66 VT-3 NA 0.000 / 0.000 Reactor Coolant Seal Return Cooler 2A Class 2 0-ISIN4-IO1A-2.1 Support.

02.F17.40.0026 F01.040.026 2-50-RCPM-2A2-SS2 0-1 066A NDE-66 VT-3 NA 0.000 / 6.000 Calculation No. OSC-0991-01-0001, Reactor Hyd Snubber Class 1 0-ISIN4-100A-2.1 Coolant Pump 2A2 Motor Snubbers.

O-ISIN-100A-2.3 Reference PIP 0-096-1575.

02.F1.40.0030 F01.040.030 2-DESW-PU OM-208-148 NDE-66 VT-3 NA 0.000 / 0.000 Diesel Engine Service Water Pump.

Class 3 0-ISIN4-133A-2.5 OM-208-129 02.F1.40.0066 F01.040.033 2-SRC-LATERAL O-0152-W-008 NDE-66 VT-3 NA 0.000 / 0.000 Unit 2 Seal Return Cooler Lateral Restraint Class 2 0-ISIN4-101A-2.1

-- ------. End of Report STATISTICS ONLY Class 1 169 Class 2 122 Class 3 35 Total by Class 326 Systems 326 Total Count 326 Printed 02/16/09ick8302 v.01/19/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 71 of 71

4.0 Results Of Inspections Performed The results of each examination shown in the final Inservice Inspection Plan (Section 3 of this report) are included in this section. The completion date and status for each examination are shown. All examinations revealing reportable indications and any corrective action required as a result are described in further detail in Subsections 4.1 and 4.2. Corrective measures performed and limited examinations are described in further detail in Subsections 4.3 and 4.4.

The information shown below is a field description for the reporting format included in this section of the report:

Summary/Item = ASME Section XI Tables IWB-2500-1 Number .(Class 1), IWC-2500-1 (Class 2), IWF-2500-1 (Class 1 and Class 2),

Augmented Requirements ID Number = Unique Identification Number Sys = Component System Identification Insp Date = Date of Examination Insp Status = CLR Clear REC Recordable REP Reportable Insp Limited = Indicates inspection was limited.

Coverage obtained is listed Geo. Ref. = Y Yes (Geometric Reflector N No applies only to UT)

= Y Yes RFR (Relief Request)

N No Comments = General and/or Detail Description EOC 23 Refueling Outage Report Page 1 of 3 Oconee Unit 2 Revision 0 Section 4 February 11, 2009

4.1 Reportable Indications EOC 23 (Outage 3) did not have any reportable indications during this report period.

4.2 Corrective Action Corrective action is action taken to resolve flaws and relevant conditions, including supplemental examinations, analytical evaluations, repair/ replacement activities, and corrective measures. There were no problems that required corrective action during this report period.

4.3 Corrective Measures Corrective measures are actions (such as maintenance) taken to resolve relevant conditions, but not including supplemental examinations, analytical evaluations, and repair / replacement activities. Any corrective measures performed for examinations associated with this report period will be shown on the examination data sheets which are on file at the Duke's Corporate Office in Charlotte, North Carolina.

PIP 0-08-06882 was written to document evidence of leakage discovered during a VT-2 examination on summary number O1 .G1 1.1.00002. The augmented examination was on the Unit 2 Reactor Vessel Head Penetrations area.

4.4 Limited Examinations Limited examinations (i.e., less than or equal to 90% of the required examination coverage obtained) identified during EOC 23 (Outage 3) are shown in the table below.

A Request for Relief will be submitted to seek NRC acceptance of the limited coverage for the items listed in the table below.

Summary/Item Descriptionof Limitation Number 02.B3.110.0012 Coverage limitation (36.24%)

02.B9.11.0031 Coverage limitation (37.50%)

02.B9.11.0058 Coverage limitation (37.50%)

02.B9.11.0067 Coverage limitation (37.50%)

EOC 23 Refueling Outage Report Page 2 of 3 Oconee Unit 2 Revision 0 Section 4 February 11, 2009

Summary/Item Descriptionof Limitation Number 02.C5.11.0005 Coverage limitation (37.50%)

02.C5.11.0021 Coverage limitation (37.50%)

02.C5.11.0025 Coverage limitation (37.50%)

02.C5.11.0034 Coverage limitation (88.90%)

02.C5.11.0036 Coverage limitation (36.81%)

02.C5.11.0067 Coverage limitation (37.50%)

02.C5.21.0027 Coverage limitation (37.50%)

02.C5.21.0029 Coverage limitation (75.00%)

02.C5.21.0031 Coverage limitation (37.50%)

02.C5.21.0055 Coverage limitation (83.50%)

02.C5.21.0256 Coverage limitation (37.50%)

EOC 23 Refueling Outage Report Page 3 of 3 Oconee Unit 2 Revision 0 Section 4 February 11, 2009

DUKE ENERMCORPORATION Scheduleworks o QUALITY ASSURANLWFECHNICAL SERVICES 0 Inservice Inspection Database Management System Inspection Results Oconee 2, 4th Interval, Outage 3 EOC-23)

FOR INFORMATION ONLY!

Insp Insp Insp Geo Summary No Component ID Sy.stem Date Status Limited Ref RFR Comment 02.B10.10.0006 2-PZR-WP82-Y 11/07/08 CLR N N N MT-08-043 02.B10.20.0002 2-51A-0-1478A-H5C 51A 11/12/08 CLR N N N PT-08-099 02.B10.20.0004 2-51A-0-1479A-H7B 51A 11/14/08 CLR N N N PT-08-112 02.112.50.0002 2-53A-CF12 53A 11/10/08 CLR N N N VT-08-257 02.B133.10.0001 2-RPV-INT-SURFACE 50 11/25/08 CLR N N N VT-08-260 02.B14.10.0001 2-RPV-CRD-52WH9 50 11/02/08 CLR N N N PT-08-076 02.B14.10.0004 2-RPV-CRD-52W60 50 11/01/08 CLR N N N PT-08-080 02.B14.10.0007 2-RPV-CRD-52 50 11/01/08 CLR N N N PT-08-081 02.314.10.0010 2-RPV-CRD-52W61 50 11/01/08 CLR N N N PT-08-082 02.B2.40.0001 2-SGA-W23 50 11/17/08 CLR N N N UT-08-158 50 11/17/08 CLR 92.30% N N UT-08-160 02.B2.40.0002 2-SGA-W22 50 11/17/08 CLR N N N UT-08-159 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 1 of 26 Printed 10:35:46 AM 2/16/2009 10:35:46 Printed 2/16/2009 AM Ick8302 v. 01 1ck8302 v. /01/08 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Pagel of26

Summary No

'"Insp Component ID System Date Insp Status InspINFO "Gee FOR Limited 4 WTION ONLY!

Ref RFR Comment 0

02.B2.40.0002 2-SGA-W22 50 11/17/08 CLR 92.30% N N UT-08-16 02.B3.110.0012 2-PZR-WP26-7 50 11/24/08 CLR 36.24% N Y UT-08-16 9 PIP 0-09 -00822 was written to document and determine the corrective action for the limite d coverage achieved for this exam.

50 11/24/08 CLR 36.24% N Y UT-08-170 PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

02.B3.120.0012 2-PZR-WP26-7 50 11/09/08 CLR N N UT-08-135 02.B3.140.0001 2-SGA-OUTLET 50 11/03/08 CLR N N VT-N/A 02.B3.140.0002 2-SGA-OUTLET 50 11/03/08 CLR N N VT-N/A 02.B3.140.0003 2-SGB-OUTLET 50 11/04/08 CLR N N VT-N/A 02.B3.140.0004 2-SGB-OUTLET 50 11/04/08 CLR N N VT-N/A 02.B3.140.0005 2-SGA-INLET 50 11/11/08 CLR N N VT-N/A 02.B3.140.0006 2-SGB-INLET 50 11/17/08 CLR N N VT-N/A 02.B6.10.0021 2-RPV-26-204-21 50 11/05/08 CLR N N VT-08-234 02.B6.110.0022 2-RPV-26-204-22 50 11/05/08 CLR N N VT-08-235 02.B6.10.0023 2-RPV-26-204-23 50 11/05/08 CLR N N VT-08-236 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 2 of 26 Printed 2/16/2009 10:35:46 v. 01 Ick8302 v.

AM 1ck8302 10:35:46 AM /01/08 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 2 of 26

FOR INF0OW TION ONLY!

Summary No Component ID System Insp Date Insp Status Insp Limited "eo Ref RFR Comment 0

02.B6.10.0024 2-RPV-26-204-24 50 11/05/08 CLR N N N VT-08-237 02.B6.10.0025 2-RPV-26-204-25 50 11/05/08 CLR N N N VT-08-238 02.B6.10.0026 2-RPV-26-204-26 50 11/05/08 CLR N N N VT-08-239 02.86.10.0027 2-RPV-26-204-27 50 11/05/08 CLR N N N VT-08-240 02.B6.10.0028 2-RPV-26-204-28 50 11/05/08 CLR N N N VT-08-241 02.B6.10.0029 2-RPV-26-204-29 50 11/05/08 CLR N N N VT-08-242 02.B6.10.0030 2-RPV-26-204-30 50 11/05/08 CLR N N N VT-08-243 02.B6.10.0031 2-RPV-26-204-31 50 11/05/08 CLR N N N VT-08-244 02.B6.10.0032 2-RPV-26-204-32 50 11/05/08 CLR N N N VT-08-245 02.B6.10.0033 2-RPV-26-204-33 50 11/04/08 CLR N N N VT-08-225 02.B6.10.0034 2-RPV-26-204-34 50 11/04/08 CLR N N N VT-08-226 02.B6.10.0035 2-RPV-26-204-35 50 11/04/08 CLR N N N VT-08-227 02.B6.10.0036 2-RPV-26-204-36 50 11/04/08 CLR N N N VT-08-228 02.B6.10.0037 2-RPV-26-204-37 50 11/04/08 CLR N N N VT-08-229 SOQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 3 of 28 2/16/2009 10:35:46 Printed 2/16/2009 lck8302 v.

AM Ick8302 10:35:46 AM 01/01/08

v. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page3 of25

FOR INFONTION ONLY!

Insp /nsp /nsp "eo Summary No Component ID System Date Status 1.imited Ref RFR Comment 02.B6.10.0038 2-RPV-26-204-38 50 11/04/08 CLR N N N VT-08-230 02.B6.10.0039 2-RPV-26-204-39 50 11/04/08 CLR N N N VT-08-231 02.B6.10.0040 2-RPV-26-204-40 50 11/04/08 CLR N N N VT-08-232 02.B6.30.0021 2-RPV-25-204-21 50 11/05/08 CLR N N N UT-08-110 02.B6.30.0022 2-RPV-25-204-22 50 11/05/08 CLR N N N UT-08-111 02.B6.30.0023 2-RPV-25-204-23 50 11/05/08 CLR N N N UT-08-112 02.B6.30.0024 2-RPV-25-204-24 50 11/05/08 CLR N N N UT-08-113 02.B6.30.0025 2-RPV-25-204-25 50 11/05/08 CLR N N N UT-08-114 02.B6.30.0026 2-RPV-25-204-26 50 11/05/08 CLR N N N UT-08-115 02.B6.30.0027 2-RPV-25-204-27 50 11/05/08 CLR N N N UT-08-116 02.B6.30.0028 2-RPV-25-204-28 50 11/05/08 CLR N N N UT-08-117 02.86.30.0029 2-RPV-25-204-51-6 2 50 11/05/08 CLR N N N UT-08-118 02.B6.30.0030 2-RPV-25-204-30 50 11/05/08 CLR N N N UT-08-119 02.B6.30.0031 2-RPV-25-204-31 50 11/05/08 CLR N N N UT-08-120 Oconee 2 2/16/2009 10:32:23 AM Page 4 of 26 Printed 2/16/2009 10:35:47 AM Ick8302 v. 01/01/08 Printed 2/16/2009 10:35:47 AM1ck8302 v. 01/01/08 Cat "C" SDQA Cat SDQA "C" Oconee 2 2/16/2009 10:32:23 AM Page 4 of 26

9 Insp Insp FOR INFOSIATION ONLY!

Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment 02.B6.30.0032 2-RPV-25-204-32 50 11/05/08 CLR N N N UT-08-121 02.B6.30.0033 2-RPV-25-204-33 50 11/04/08 CLR N N N UT-08-102 O2.B6.30.0034 2-RPV-25-204-34 50 11104/08 CLR N N N UT-08-103 02.B6.30.0035 2-RPV-25-204-35 50 11/04/08 CLR N N N UT-08-104 02.B6.30.0036 2-RPV-25-204-36 50 11/04/08 CLR N N N UT-08-105 02.B6.30.0037 2-RPV-25-204-37 50 11/04/08 CLR N N N UT-08-106 02.B6.30.0038 2-RPV-25-204-38 50 11/04/08 CLR N N N UT-08-107 02.B6.30.0039 2-RPV-25-204-39 50 11/04/08 CLR N N N UT-08-108 02.B6.30.0040 2-RPV-25-204-40 50 11/04/08 CLR N N N UT-08-109 02.B6.50.0002 2-RPV-WASH-BUSH 50 11/04/08 CLR N N N VT-08-233 Leo Paquin examined washers for stud holes 33 to 40 on-11-4-2008 and Ronald McCollough examined washers for stud holes 21 thru 32 on 11-5-2008.

10/27/08 CLR 02.B7.20.0002 2-PZR-CHB-STUDS 50 N N N VT-08-211 10/27/08 CLR 02.B7.50.0003 2-PZR-RC67-STUDS 50 N N N VT-08-212 10/27/08 CLR 02.B7.50.0004 2-PZR-RC68-STUDS 50 N N N VT-08-213 02.19.11.0003 2-PSP-3 50 11/14/08 CLR N N N PT-08-110 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 5 of 26 Printed 2/16/2009 AM 1ck8302 10:35:47 AM 2/16/2009 10:35:47 v. 01/01/08 Ick8302 v. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 5 of 26

FOR INFORIM N ONLY!

Summary No Component ID System Insp Date Insp Status Insp Limited Geo Ref RFR Comment 0

02.B9.11.0003 2-PSP-3 50 11/15/08 CLR N Y N UT-08-153 Indication # 1- 45

  • was determined to be geometry (360
  • continuous) 02.19.11.0004 2-PIB2-3 50 11/13108 CLR N N MT-08-046 50 11/14/08 CLR N N UT-08-149 02.B9.11.0005 2RC-279-89V 50 10/31/08 CLR N N MT-08-034 50 10/31/08 CLR N N UT-08-094

-2.B9.1-1.0023 2SGA-W2 50 11/02/08 CLR N N MT-08-035 50 11/03/08 CLR N N UT-08-100 02.B9.111.0025 2SGA-W3 50 11/02/08 CLR N N MT-08-036 50 11/03/08 CLR N N UT-08-101 50 11/13/08 CLR N 02.B9.111.0027 2SGB-W3 N MT-08-047 50 11/14/08 CLR N N UT-08-151 50 11/02/08 CLR N 02.B9.11.0031 2-PIB2-8 N PT-08-074 50 11/06/08 CLR 37.50% N Y UT-08-132 PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

Printed 2/16/2009 3:13:49 PM Ick8302 v. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 3:12:24 PM Page 6 of 26

FOR INFQW TION ONLY!

Summary No Component ID System Insp Date fnsp Status (nsp Limited

.eo Ref RFR Comment 0

02.89.11.0031 2-PI1B2-8 50 11/06/08 CLR N Y UT-08-134 Best effort exam of upper 2/3 of weld to supplement coverage.

PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

02.B9.11.0043 2RC-279-91V 50 11/02/08 CLR N N MT-08-037 50 11/04/08 CLR N N UT-08-124 02.B9.11.0044 2-PlA1-3 50 11/02/08 CLR N N MT-08-038 50 11/03/08 CLR N N UT-08-099 02.B9.11.0049 2-2RC-279-90V 50 11/02/08 CLR N N MT-08-039 50 11/04/08 CLR N N UT-08-125 02.B9.11.0055 2RC-279-95V 50 11/13/08 CLR N N MT-08-048 50 11/14/08 CLR N N UT-08-152 02.B9.11.0056 2-PIB1-3 50 11/14/08 CLR N N MT-08-049 50 11/14/08 CLR N N UT-08-150 02.B9.11.0058 2-PIB1-8 50 11/02/08 CLR N N N PT-08-075 50 11/06/08 CLR 37.50% N Y UT-08-131 PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 7 of 28 10:35:47 AM Printed 2/16/2009 10:35:47 1ck8302 v.

AM Ick8302 01/01/08

v. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 7 of 26

1s l Insp FOR Inspj INFO ATION eo ONLY!

0 "Insp Summary No Component ID System Date Status Limited Ref RFR Comment 02.B9.11.0058 2-PIB1-8 50 11/06/08 CLR N Y UT-08-133 Best effort exam of upper 2/3 of weld to supplement coverage.

PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

02.B9.11.0067 2-53A-10-3 53A 11/12/08 CLR N N N PT-08-097 53A 11/13/08 CLR 37.50% N Y UT-08-141 PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

02.19.11.0071 2-53A-8-43 53A 11/12/08 CLR N N N PT-08-098 53A 11/13/08 CLR N N N UT-08-142 02.B9.21.0015 2RC-253-5 50 10/31/08 CLR N N N PT-08-071 02.B9.21.0016 2RC-253-6 50 10/31/08 CLR N N N PT-08-072 02.B9.21.0021 2-PSP-14 50 11/14/08 CLR N N N PT-08-111 02.B9.21.0030 2HP-216-9 51A 11/18/08 CLR N N N PT-08-118 02.B9.21.0049 2-51A-30-15 51A 11/12/08 CLR N N N PT-08-095 02.B9.21.0052 2-51A-30-40 51A 11/12/08 CLR N N N PT-08-096 02.B9.21.0054 2-51A-35-28A 51A 11/14/08 CLR N N N PT-08-103 02.B9.21.0055 2-51A-35-33 51A 11/14/08 CLR N N N PT-08-104 Printed 2/16/2009 10:35:47 AM Ick8302 v. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 8 of 26

0 Insp Insp FOR INF(OTION ONLY!

fnsp Geo Summary No Component ID System Date Status Limited Ref RFR Comment 02.B9.21.0228 2HP-495-26 51A 11/05/08 CLR N N N PT-08-089 02.B9.31.0002 2-PHA-16 50 11/16/08 CLR N N N MT-08-050 02.B9.32.0006 2-PIAl-10 50 11/02/08 CLR N N N MT-08-040 02.B9.40.0004 2RC-271-3B 50 10/31/08 CLR N N N PT-08-073 02.B9.40.0006 2-50-7-127 50 11/02/08 CLR N N N PT-08-077 02.B9.40.0011 2-51A-145-26 51A 11/05/08 CLR N N N PT-08-090 02.C1.30.0007 2-RCSRCA-SH-TS-1 51A 08/08107 CLR N N N PT-07-060 02.01.30.0008 2-RCSRCA-SH-TS-2 51A 08/08/07 CLR N N N PT-07-061 02.C2.21.0002 2-SGA-W128 11/18/08 CLR N N N MT-08-054 11/19/08 CLR N N N UT-08-162 11/19/08 CLR N N N UT-08-163 02.C3.20.0006 2-03-0-1480A-H7A 03 11/12/08 CLR N N N MT-08-045 02.C3.20.0011 2-14B-0-1479A-H12 14B 11/07/08 CLR N N N MT-08-044 02.C3.20.0015 2-51A-1-0-436J-SR1 16 51A 11/04/08 CLR N N N PT-08-087 02.C3.20,0017 2-51A-0-1478A-H10C 51A 11/18/08 CLR N N N PT-08-117 Printed 2/16/2009 10:35:47 AM Ick8302 v. 01/0 1/08 1/08 ~~~~~~~SDQA Cat "C" Oc O onee oe 2 2/16/2009

/620 10:32:23 03:3AAM ae 9of26 Page f2

FOR INFO0TI0N ONL 0 Insp fnsp /nsp "eo Summary No Component ID System Date Status Limited Ref RFR Comment 02.C3.20.0020 2-53-0-1478A-H5 53 11/13/08 CLR N N N PT-08-100 02.C3.20.0022 2-53B-10-0-435B-H2 53B 07/21/08 CLR N N N PT-08-062 02.C3.20.0026 2-53B-5-0-1439C-H31 53B 07/23/08 CLR N N N PT-08-063 02.C4.30.0001 2-HPI-PUMP-2A 51A 08/28/07 CLR N N N UT-08-140 02.C5.11.0005 2LP-150-17 53A 11/10/08 CLR N N N PT-08-091 53A 11/11/08 CLR 37.50% Y Y UT-08-139 PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

Indication # 1-60L was due to geometry.

02.C5.11.0021 2LP-217-8 53A 11/13/08 CLR N N N PT-08-101 53A 11/13/08 CLR 37.50% N Y UT-08-156 PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

02.C5.11.0022 2-53A-9-1 0 53A 11/14/08 CLR N N N PT-08-105 53A 11/14/08 CLR N N N UT-08-144 02.C5,11.0023 2-53A-9-1 1 53A 11/10/08 CLR N N N PT-08-092 53A 11/11/08 OLR N N N UT-08-136 02.C511.0024 2-53A-9-12 53A 11/10/08 CLR N N N PT-08-093 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 10 of 26 Printed 2/16/2009 AM 1ck8302 10:35:47 AM 2/16/2009 10:35:47 v. 01/01/08 Ick8302 v. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 10 of 26

FOR INFO*ATION ONLY fnsp (nsp /nsp. 0'eo Summary No Component ID System Date Status Limited Ref RFR Comment 02.C5.11.0024 2-53A-9-12 53A 11/11/08 CLR N N N UT-08-137 02.C5.11.0025 2-53A-9-16 53A 11/10/08 CLR N N N PT-08-094 53A 11/11/08 CLR 37.50% Y Y UT-08-138 Indication # 1-60L was due to geometry.

PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

02.C5.11.0026 2-53A-9-4 53A 11/14/08 CLR N N N PT-08-106 53A 11/14/08 CLR N N N UT-08-145 02.C5.11.0027 2-53A-9-5 53A 11/14/08 CLR N N N PT-08-107 53A 11/14/08 CLR N N N UT-08-146 02.C5.11.0028 2-53A-9-6 53A 11/14/08 CLR N N N PT-08-108 53A 11/14/08 CLR N N N UT-08-147 02.C5.11.0033 2LP-189-13 53A 11/16/08 CLR N N N PT-08-115 53A 11/17/08 CLR N N N UT-08-154 02.C5.11.0034 2LP-189-14 53A 11/16/08 CLR 95.55% N N PT-08-116 53A 11/17/08 CLR 88.90% N Y UT-08-155 PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

02.C5.11.0035 2LP-215-1 53A 11/14/08 CLR N N N PT-08-109 Printed 2/16/2009 10:35:47 AM Ick8302 v. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 11 of 26

FOR INFQWTION ONLY!

Insp Insp Insp Geo.

Summary No Component ID System Date Status Limited Ref RFR Comment 02.C5.11.0035 2LP-215-1 53A 11/14/08 CLR N N N UT-08-148 02.C5.11.0036 2LP-215-17 53A 11/19/08 CLR N N N PT-08-123 53A 11/19/08 CLR 36.81% N Y UT-08-164 PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

02.C5.11.0067 2LP-218-23 53A 11/13/08 CLR N N N PT-08-102 53A 11/13/08 CLR 37.50% N Y UT-08-157 PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

02.C5.11.0071 2LPS-724-10 14B 11/19/08 CLR N N N PT-08-119 14B 11/19/08 CLR N N N UT-08-165 02.C5.11.0076 2LPS-724-18 14B 11/19/08 CLR N N N PT-08-120 14B 11/19/08 CLR N N N UT-08-166 02.C5.11.0079 2LPS-724-8 14B 11/19/08 CLR N N N PT-08-121 14B 11/19/08 CLR N N N UT-08-168 02.C5.11.0080 2LPS-724-9 14B 11/19/08 CLR N N N PT-08-122 14B 11/19/08 CLR N N N UT-08-167 02.C5.21.0004 2-RCP-FTR2B-SH-2 51A 11/02/08 CLR N N N RT-N/A SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 12 of 26 10:35:47 AM 2/16/2009 10:35:47 Printed 2/16/2009 AM Ick8302 v. 01/01/08 1ck8302 v. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 12 of 26

FOR INFWTION ONLY!

(nsp Insp fnsp Geo Summary No Component ID System Date Status Limited Ref RFR Comment 02.C5.21.0027 2-51A-28-15 51A 11/03/08 CLR N N N PT-08-083 51A 11/04/08 CLR 37.50% Y Y UT-08-127 Indication # 1 and Indication # 2 are geometrical reflectors due to root geometry.

PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

02.C5.21.0028 2-51A-28-17 51A 11/03/08 CLR N N N PT-08-084 51A 11/04/08 CLR N N N UT-08-128 02.C5.21.0029 2-51A-28-21 51A 11/03/08 CLR N N N PT-08-085 51A 11/04/08 CLR 75.00% N Y UT-08-129 PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

02.C5.21.0030 2-51A-28-23 51A 11/03/08 CLR N N N PT-08-086 51A 11/04/08 CLR N N N UT-08-130 02.C5.21.0031 2HP-222-2 51A 07/28/08 CLR N N N PT-08-064 51A 11/03/08 CLR 37.50% N Y UT-08-088 PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

02.C5.21.0032 2HP-222-104 51A 07/28/08 CLR N N N PT-08-065 51A 07/29/08 CLR N N N UT-08-089 02.C5.21.0055 2-51 A-1 7-93 51A 07/21/08 CLR N N N PT-08-066 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 13 of 26 Printed 2/16/2009 10:35:47 AM 2/16/2009 10:35:47 AM Ick8302 v. 01/01/08 1ck8302 v. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 13 of 26

FOR INFO# TION ONLY!

9 ,nsp Insp Insp eo Summary No Component ID System Date Status Limited Ref RFR Comment 02.C5.21.0055 2-51 A-1 7-93 51A 07/22/08 CLR 83.50% N Y UT-08-087 PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

02.C5.21.0256 2HP-221-22 51A 07/23/08 CLR N N N PT-08-067 51A 07/29/08 CLR 37.50% N Y UT-08-086 PIP 0-09-00822 was written to document and determine the corrective action for the limited coverage achieved for this exam.

02.C5.30.0003 2-51 B-23-67 51B 11/04/08 CLR N N N PT-08-088 02.C5.51.0002 2-01A-4-29 01A 10/30/08 CLR N N N MT-08-032 01A 10/31/08 CLR N Y N UT-08-095 Indication # 1 and Indication # 2 are geometric reflectors due to a heavy root configuration.

02.C5.51.0004 2MS-124-71V 01A 11/06/08 CLR N N N MT-08-041 01A 11/06/08 CLR N N N UT-08-126 02.C5.51.0011 2-MSB10-E 01A 10/30/08 CLR N N N MT-08-030 01A 10/30/08 CLR IN Y N UT-08-093 Indication # 1-60 is due to geometry.

02.C5.51.0025 2MS-132-54 01A 10/29/08 CLR N N N MT-08-029 01A 10/29/08 CLR N N N UT-08-090 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 14 of 26 Printed 2/16/2009 10:35:47AM 2/16/2009 10:35:47 Ick8302 v.01/01/08 AM 1ck8302 v. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 14 of 26

FOR INF(VTION ONLY!

Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment 02.C5.51.0031 2-144B-49-136 14B 07121/08 CLR N N N MT-08-023 14B 07/22/08 CLR N N N UT-08-083 02.C5.51.0032 2MS-136-209 01A 10/28/08 CLR N N N MT-08-026 01A 10/29/08 CLR N Y N UT-08-092 Indication # 1 is due to geometry.

02.C5.51.0033 2-14B-50-111 14B 07/21/08 CLR N N N MT-08-024 14B 07/22/08 CLR N N N UT-08-084 02.C5.51.0034 2LPS-606-4 14B 07/21/08 CLR N N N MT-08-025 14B 07/22/08 CLR N N N UT-08-085 02.C5.51.0037 2MS-1 36-9A 01A 10/28/08 CLR N N N MT-08-027 01A 10/29/08 CLR N N N UT-08-091 02.C5.61.0001 2SGA-W250-4 03A 11/16/08 CLR N N N MT-08-051 03A 11/12/08 CLR N N N RT-N/A 02.C5.61.0002 2SGA-W251-4 03A 11/16/08 CLR N N N MT-08-052 03A 11/12/08 CLR N N N RT-N/A 02.C5.61.0036 2SGA-W335 03A 11/16/08 CLR N N N MT-08-053 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 15 of 26 10:35:47 AM Printed 2/16/2009 10:35:47 1ck8302 v.

AM Ick8302 01/01/08 V. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 15 of 26

FOR INF(*"\TION ONLY!

Summary No Component ID System Insp Date tnsp Status Ins#-I Limited Ref o

RFR Comment 0

02.C5.61.0036 2SGA-W335 03A 11/12/08 CLR N N N RT-N/A 02.C5.70.0002 2-03A-1 0-57 03A 07/21/08 CLR N N N PT-08-068 02.C5.70.0003 2-03A-1 0-58 03A 07/21/08 CLR N N N PT-08-069 02.C5.81.0004 2-FWD63-B 03 11/06/08 CLR N N N MT-08-042 02.C5.81.0005 2-03A-1 0-56 03A 07/21/08 REC N N N PT-08-070 Rounded indication that was .100 inches in diameter and is acceptable.

02.D1.20.0001 2-01A-4-0-1400H-DJB1004 01A 07/23/08 CLR N N VT-08-136 02.D1.20.0003 2-01 A-4-2-0-1400A-R27 01A 07/23/08 CLR N N VT-08-156 02.D1.20.0024 2-14B-1-0-1439B-H18 14B 07/23/08 CLR N N VT-08-157 02.D1.20.0092 2-14B-0-1439A-H34 14B 07/23/08 CLR N N VT-08-158 02.F1.10.0004 2-51A-0-1478A-H5C 51A 11/03/08 CLR N N VT-08-219 02.F1.11.0003 2-51A-0-1479A-H8A 51A 11/03/08 CLR N N VT-08-220 02.F1.11.0004 2-51A-0-1479A-H7B 51A 11/16/08 REC N N VT-08-259 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order 968488 was written to correct problems.

SDQA Cat "C' Oconee 2 2/16/2009 10:32:23 AM Page 16 of 26 Printed 2/16/2009 Printed Ick8302 v.

AM 1ck8302 10:35:47 AM 2/16/2009 10:35:47 01/01/08

v. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 16 of 26

0 fnsp insp FOR INFQeTION ONLY!

Insp eo Summary No Component ID System Date Status Limited Ref RFR Comment O2.F1.11.0009 2-53A-0-1478A-H4A 53A 11/03/08 REC N N N VT-08-221 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

02.F1.12.0003 2-50-0-1480A-H8 50 12/03/08 CLR N N N VT-08-265 02.F1.12.0010 2-57-0-1481 A-CEW-H0802 57 10/31/08 CLR N N N VT-08-216 02.F1.20.0023 2-51A-0-1478A-H1OC 51A 11/16/08 REC N N N VT-08-266 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order 969255 was written to correct problems.

02.F1.20.0024 2-51 A-0-1 439A-H 175 51A 07/17/08 CLR N N N VT-08-138 02.F1.20.0029 2-51A-2-0-437B-H7 51A 07/17/08 CLR N N N VT-08-139 02.F1.20.0030 2-51A-3-0-437B-H6 51A 07/17/08 REC N N N VT-08-160 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order 964940 was written to correct problems.

N N N VT-08-140 02.F1.20.0032 2-51 B-2-0-436E-H 55 51B 07/17/08 CLR N N N VT-08-141 02.F1.20.0037 2-53B-0-1436A-DE054 53B 07/17/08 CLR N N N VT-08-161 02.F1.20.0044 2-53B-5-0-1439C-H31 53B 07/23/08 REC The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

02.F1.20.0050 2-54A-3-0-435B-R2 54A 07/17/08 CLR N N N VT-08-142 Printed 2/16/2009 10:35:47 AM Ick8302 v. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 17 of 26

0 Insp Insp FOR INFQ#TION ONLY!

Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment 02.F1.20.0051 2-54A-3-0-1439A-H25 54A 07/17/08 CLR N N N VT-08-143 02.F1.21.0004 2-14B-0-1479A-H1-2 14B 11/09/08 REC N N N VT-08-246 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order 967159 was written

<. to correct problems.

02.F1.21.0015 2-51A-1-0-436J-SR1 16 51A 11/02/08 REC N N N VT-08-222 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

02.F1.21.0024 2-51 B-436J-DE012 51B 11/02/08 CLR N N N VT-08-217 02.F1.21.0031 2-53B-0-1439A-DE048 53B 07/17/08 REC N N N VT-08-162 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order 969172 was written to correct problems.

02.F1.21.0033 2-53-0-1478A-H5 53 11/09/08 REC N N N VT-08-247 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order 967162 was written to correct problems.

02.F1.22.0007 2-O1A-0-1401R-H7 01A 10/30/08 REC N N N VT-08-171 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

02.F1.22.0010 2-03-0-1480A-H7A 03 10/31/08 CLR N N N VT-08-215 02.F1.22.0011 2-03A-1480A-H6B 03A 10/31/08 CLR N N N VT-08-218 02.F1.22.0016 2-51A-435B-DKB-1410 51A 07/17/08 CLR N N N VT-08-134 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 18 of 26 Printed 2/16/2009 Printed AM 1ck8302 10:35:47 AM 2/16/2009 10:35:47 v. 01 Ick8302 v. /01/08 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 18 of 26

0 Insp Insp FOR INF(O TION ONLY!

Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment 02.F1.22.0018 2-53B-10-0-435B-H2 53B 07/23/08 REC N N N VT-08-163 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

02.F1.22.0056 2-01A-0-1401B-H18 01A 10/30/08 REC N N N VT-08-172 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

02.F1.30.0002 2-01A-4-0-1400H-DJB1004 01A 07/23/08 CLR N N N VT-08-144 02.F1.30.0004 2-03A-1401A-GC-907 03A 07/17/08 CLR N N N VT-08-145 02.F1.30.0027 2-07A-6-0-1402A-R44 07A 12/01/08 REC N N N VT-08-262 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

02.F1.30.0033 0-13-447A-H7042 13 07/17/08 CLR N N N VT-08-146 02.F1.30.0034 0-14-447A-H7020 14 07/17/08 REC N N N VT-08-165 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

02.F1.30.0036 2-14B-1437A-H25 14B 07/17/08 REC N N N VT-08-166 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

02.F1.30.0042 2-14B-1-0-1 439B-DEl182 14B 07/17/08 REC N N N VT-08-167 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

02.F1.31.0010 2-03A-1 1401 B-SR 11 03A 07/17/08 CLR N N N VT-08-147 Printed 2/16/2009 10:35:47 AM Ick8302 v. 01101/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 19 of 26

FOR INFHOTION ONLY!

Insp Insp Insp eo Summary No Component ID System Date Status Limited Ref RFR Comment 02.F1.31.0014 2-07A-0-1400A-SR3 07A 07/23/08 CLR N N N VT-08-148 O2.F1.31.0018 0-13-447A-H7007 13 07/17/08 CLR N N N VT-08-151 02.F1.31.0151 2-14B-0-1439A-H34 14B 07/23/08 REC N N N VT-08-168 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order 964767 was written to correct problems.

02.F1.32.0001 2-01A-4-0-1403D-H8 01A 10/30/08 REC N N N VT-08-173 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order 966724 was written to correct problems.

02.F1.32.0002 2-01 A-4-2-0-1400A-R27 01A 07/23/08 REC N N N VT-08-159 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order 964771 was written to correct problems.

02.F1.32.0013 2-14B-1-0-1439B-H-18 14B 07/23/08 CLR N N N VT-08-135 02.F1.32.0015 2-57-0-1481A-H16 57 12/03/08 CLR N N N VT-08-263 02.F1.40.0009 2-EFDW-MD-PU-A 07/23/08 CLR N N N VT-08-149 02.F1.40.0011 2-EFDW-PU-TD 07/23/08 CLR N N N VT-08-150 02.F1.40.0018 2-RCSR-COOLER-A 08/09/07 CLR N N N VT-08-152 02.F1.40.0026 2-50-RCPM-2A2-SS2 11/10/08 REC N N N VT-08-248 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 20 of 26 Printed 2/16/2009 AM 1ck8302 10:35:47 AM 2/16/2009 10:35:47 v. 01/01/08 Ick8302 v. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 20 of 26

0 fnsp Insp FOR INFQWTION ONLY!

Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment 02.F1.40.0030 2-DESW-PU 07/17/08 CLR N N N VT-08-153 02.F1.40.0066 2-SRC-LATERAL 08/09/07 CLR N N N VT-08-154 02.G1.1.0006 2-RCP-2B1 50 CLR N N N MT-N/A 50 06/25/08 CLR N N N UT-N/A 02.G1 1.1.0002 2-RPV-HEAD-PEN 50 11/02/08 CLR N N N VT-08-214 PIP 0-08-06882 was written to document leakage detected that was from the CC system.

02.G13.1.0011 2-PZR-WP63-1 50 10/28/08 CLR N N N VT-08-175 02.G13.1.0012 2RC-240-6B 50 10/28/08 CLR N N N VT-08-176 02.G13.1.0013 2-PZR-WP63-2 50 10/23/08 CLR N N N VT-08-177 02.G13.1.0014 2RC-240-9A 50 10/28/08 CLR N N N VT-08-178 02.G13.1.0015 2-PZR-WP63-3 50 10/28/08 CLR N N N VT-08-179 O2.G13.1.0016 2RC-240-4A 50 10/28/08 CLR N N N VT-08-180 02.G13.1.0017 2-PZR-WP63-4 50 10/28/08 CLR N N N VT-08-181 02.G13.1.0018 2RC-240-25V 50 10/28/08 CLR N N N VT-08-182 02.G13.1.0019 2-PZR-WP63-5 50 10/28/08 CLR N N N VT-08-183 Printed 2/16/2009 100:35:47 AM Ick8302 v. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 21 of 26

0 Insp Insp FOR INFc.TION ONLY!

Insp eo Summary No Component ID System Date Status Limited Ref RFR Comment 02.G13.1.0020 2RC-240-1A 50 10/28/08 CLR N N N VT-08-184 O2.G13.1.0021 2-PZR-WP63-6 50 10/28/08 CLR N N N VT-08-185 O2.G13.1.0022 2RC-240-21V 50 10/28108 CLR N N N VT-08-186 O2.G13.1.0023 2-PZR-WP63-7 50 10/28/08 CLR N N N VT-08-187 02.G13.1.0024 2RC-206-6 50 10/28/08 CLR N N N VT-08-188 02.G13.1.0026 2RC-278-66 50 10/27/08 CLR N N N VT-08-249 02.G13.1.0027 2RC-278-70V 50 10/27/08 CLR N N N VT-08-258 02.G13.1.0028 2RC-277-50 50 10/27/08 CLR N N N VT-08-250 02.G13.1.0029 2RC-277-71V 50 10/27/08 CLR N N N VT-08-189 02.G13.1.0030 2RC-278-23 50 10/27/08 CLR N N N VT-08-251 02.G13.1.0031 2RC-278-69 50 10/27/08 CLR N N N VT-08-252 02.G13.1.0032 2RC-277-24 50 10/27/08 CLR N N N VT-08-190 02.G13.1.0033 2RC-277-70 50 10/27/08 CLR N N N VT-08-253 02.G13.1.0034 2RC-325-8A 50 10/28/08 CLR N N N VT-08-191 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 22 of 26 Printed AM 1ck8302 10:35:47 AM 2/16/2009 10:35:47 Printed 2/16/2009 v. 01/01/08 Ick8302 V. 01/01/08 SDQA Cat "C'" Oconee 2 2/16/2009 10:32:23 AM Page 22 of 26

FOR INFQ(WTION ONLY!

Insp Insp Insp leo Summary No Component ID System Date Status Limited Ref RFR Comment 02.G13.3.0001 2SGA-HL-CON-36 50 10/27/08 CLR N N N VT-08-254 02.G13.3.0002 2SGB-HL-CON-27 50 10/27/08 CLR N N N VT-08-192 02.G13.4.0001 2SGA-2A1-SUCT-CON-11 50 10/28/08 CLR N N N VT-08-255 02.G13.4.0002 2SGA-2A2-SUCT-CON-14 50 10/28/08 CLR N N N VT-08-256 02.G13.4.0003 2SGB-2B1-SUCT-CON-3 50 10/27/08 CLR N N N VT-08-193 02.G13.4.0004 2SGB-2B2-SUCT-CON-7 50 10/27/08 CLR N N N VT-08-194 02.G14.1.0001 2-PZR-THERM 50 10/28/08 CLR N N N VT-08-195 02.G14.1.0008 2-PZR-WP63-1 50 10/28/08 CLR N N N VT-08-196 02.G14.1.0009 2RC-240-6B 50 10/28/08 CLR N N N VT-08-197 02.G14.1.0010 2-PZR-WP63-2 50 10/28/08 CLR N N N VT-08-198 02.G14.1.0011 2RC-240-9A 50 10/28/08 CLR N N N VT-08-199 02.G14.1.0012 2-PZR-WP63-3 50 10/28/08 CLR N N N VT-08-200 N N- N . . .

-V-T------... . . . . . . .

50 10/28/08 CLR 02.G14.1.0013 2RC-240-4A N N N VT-08-201 50 10/28/08 CLR N N N VT-08-202 02.G14.1.0014 2-PZR-WP63-4 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 23 of 26 Printed 2/16/2009 10:35:47 AM 1ck8302 10:35:47 AM v. 01/01/08 Ick8302 v. 01/01/08 SDQA Cat "C" Oconee 2 2/1612009 10:32:23 AM Page 23 of 26

FOR INF(@TION ONLY!

Insp Jnsp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment 02.G14.1.0015 2RC-240-25V 50 10/28/08 CLR N N N VT-08-203 02.G14.1.0016 2-PZR-WP63-5 50 10/28/08 CLR N N N VT-08-204 02.G14.1.0017 2RC-240-1A 50 10/28/08 CLR N N N VT-08-205 02.G14.1.0018 2-PZR-WP63-6 50 10/28/08 CLR N N N VT-08-206 02.G14.1.0019 2RC-240-21V 50 10/28/08 CLR N N N VT-08-207 02.G14.1.0020 2-PZR-WP63-7 50 10/28/08 CLR N N N VT-08-208 02.G14.1.0021 2RC-206-6 50 10/28/08 CLR N N N VT-08-209 02.G14.1.0023 2RC-325-8A 50 10/28/08 CLR N N N VT-08-210 02.H2.1.0009 2-PIB1-12 50 11/15/08 CLR N N N PT-08-113 O2.H2.11.0010 2-PIB2-12 50 11/15/08 CLR N N N PT-08-114 02.H3.1.0007 2-03-18-25 03 11/04/08 CLR N Y N UT-08-122 Indication # 1 and indication # 2 are geometric reflectors due to backing ring.

02.H3.1.0008 2-03-18-25G 03 11/04/08 CLR N Y N UT-08-123 Indication # 1 and indication # 2 are geometric reflectors due to backing ring.

02.H3.1.0009 2-03-18-43A 03 11/01/08 CLR N y N UT-08-096 Indication # 1 and indication # 2 are geometric reflectors due to backing ring.

SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 24 of 26 Printed 2/1612009 Ick83O2 v.

AM 1ck8302 10:35:47 AM 2/16/2009 10:35:47 01/01/08

v. 01/01/08 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 24 of 26

FOR INFVTION ONLY!

Insp Insp Insp Geo Summary No Component ID System Date Status Limited Ref RFR Comment 02.1-3.1.0010 2-FWD60-A 03 11/01/08 CLR N Y N UT-08-097 Indication # 1 and indication # 2 are geometric reflectors due to backing ring.

02.H3.1.0011 2-03-18-43AA 03 11/01/08 CLR N Y N UT-08-098 Indication # 1 and indication # 2 are geometric reflectors due to backing ring.

02.H4.1.0009 2-03-0-1401A-R1 1 03 10/26/08 CLR N N N VT-08-155 02.H4.1.0010 2-03-0-551--H49 03 10/30/08 CLR N N N MT-08-031 03 12/01/08 CLR N N N VT-08-261 02.H4.1.0011 2-03-0-551-H48 03 10/28/08 CLR N N N MT-08-028 03 10/26/08 REC N N N VT-08-169 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order 969281 and Work Order 1795440 were written to correct problems.

02.H4.1.0012 2-03-0-1439A-H63 03 11/01/08 CLR N N N PT-08-078 03 10/31/08 REC N N N VT-08-223 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

02.H4.1.0013 2-03-0-1439A-H61 03 11/01/08 REC N N N PT-08-079 The rounded indications were acceptable per IWB-3514-4.

03 10/31/08 REC N N N VT-08-224 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service. Work Order 983756651 was written to correct problems.

SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 25 of 26 Printed 10:35:48 AM 2/16/2009 10:35:48 Printed 2/16/2009 AM Ick8302 v. 01/01/08 1ck8302 v. 0 1/0 1108 SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 25 of 26

FOR INFQOTION ONLY!

0 Insp Insp Insp eo Summary No Component ID System Date Status Limited Ref RFR Comment 02.H4.1.0014 2-03-0-5511-H60 03 10/31/08 CLR N N N MT-08-033 03 10/26/08 REC N N N VT-08-170 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

02.H4.1.0029 2-01 A-0-1401 B-H7 01A 10/30/08 REC N N N VT-08-174 The discrepancies that were found were reviewed by civil engineering and the support was found to be acceptable for service.

Oconee 2 2/16/2009 10:32:23 AM Page 26 of 26 10:35:48 AM Printed 2/16/2009 10:35:48 01/01/08

v. 01/01/08 1ck8302 v.

AM Ick8302 SDQA Cat "C" SDQA Cat "C" Oconee 2 2/16/2009 10:32:23 AM Page 26 of 26

5.0 Owner's Report for Repair and Replacement Activities As required by the applicable code, records of Class 1 and Class 2 Repair and Replacement work is included on NIS-2 forms in this section.

Due to station processing and approval time frames, three categories of repair and replacement documentation exist for: 1) work performed during a prior refueling cycle; 2) work performed during the current refueling cycle; and 3) work completed but documentation not yet reviewed and approved.

There were no items for Category 1 during this reporting period.

Category 2 had 63 NIS-2 forms for work orders completed during this reporting period. Copies of the NIS-2 forms are included in this section of the report.

There were 5 items for Category 3 during this reporting period. PIP 0-09-00530 was written to document the work orders that had work completed during this report period but the documentation was not completed in time for the NIS-2 forms to be incorporated into this report.

The individual work request documents and manufacturers' data reports are on file at Oconee Nuclear Station.

5.1 Class I and 2 Preservice Examinations As required by the applicable code, Preservice Inspection (PSI) Examinations were performed on ISI Class 1 items during this report period. PSI Examination data for items listed below is on file in the Oconee Nuclear Station QA Vault.

In addition to the information above, there is a list for PSI exams that were performed and the list is located behind the NIS-2 forms in this section. The list has one page and is entitled "Preservice Examinations of Class 1 & 2 Welds".

PSI examination data for items on the list previously mentioned is on file in the Oconee Nuclear Station QA Vault.

EOC 23 Refueling Outage Report Page 1 of 1 Oconee Unit 2 Revision 0 Section 5 February 11, 2009

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl U

Work Order Number Sheet a

i 01676536 I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station - ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/5/2009
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Injection, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Valve 2LP- 181 Flowserve 50AXW 1198 UNK 2003 Removed YES Valve 2LP-181 Flowserve 21BLD 2207 UTC 1911962 2008 Installed YES 52AWX Valve 2LP-180 BW/IP Intern 2AWX 1201 UNK 2003 Removed YES 2748AT680 2

Valve 2LP- 180 Flowserve 25BLD 2211 UTC 1911966 2008 Installed YES L J. I J. I 4- 4 1- t 1- t 1~ I "7

I rfl=grinfinn nf WAnrk

______________ _______________ I ______________ F___________ I............i

____________ I -

OE200649 replaced valves 2LP-180, 2LP-181, 2LP-182, 2LP-187, 2LP-188, and 2LP-189 with valve item # 09J-2005.

Note: Valves 2LP-180 and 2LP-181 are ISI ClassA. All others are I" and ISI Class B.

,- I

8. Test Conducted flHydrostatic i Pneumatic Z Nominal Operating Pressure, "r Exempt _D Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I I Work Order Number Sheet 01676536 2 of 2 IF ll 7

V9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0

0 0

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed William W Foster Jr, Engineer II Date 1/5/2009 6

Owner or wner's Designee., Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,&V-// (f, , and employed by HSB CT of Hartford, Connecticut have inspected the components describe(d in this Owner's Report during the period 4 -/R- 0 a to / - - 0_7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described-in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

  • By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.- 7Furthermore, - eithVer-the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_______________________ Commissions I"nspector's Signature National Board, State, Province, and Endorsements Date _-1_ 0 7

Porm NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl Work Order Number Sheet 1681455 I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/20/2009
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class RC, ASME Class I 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Angle A

4"x3"x 1/4"x8" DPCo None None UTC0001075716 Installed NO long (2) 3/8" Bolt (2)

DPCo None None UTC0001043512 Installed (A307) NO

4) 3/8" Heavy Flex Nut (At192 DPCo None None UTCOOO1911792 Installed NO Gr2H)
7. Description of Work Attach the above items to existing support 53-0-1478A-H3, by bolting, per OD200454 (EC89720 Rev. 6)
8. Test Conducted Li"Hydrostatic I-1 Pneumatic 1:1 Nominal Operating Pressure Exempt ] Other Pressure PSI Test Temperature _F

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1681455 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 All itemns attached to existing support 53-0-1478A-H3 which is a Class 1 support. the tubing itself is Class 2.

0 0

0 0

o 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed Mechanical Engineer Date 1/20/2009

  • ._.../ Owner or Owner's Designee, Title .. ...

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Vo,,,er and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7-z V-o8 to /-e..2 - o , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____te ________ Commissions AJC_'-% ,

,Co National Board, State, Province, and Endorsements Date_ _ -o

6-Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number 1 Sheet of 5 01742572

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1 11-26-08
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant System, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) N-504-2, N-659-0, and N-638 for Weld Overlay Only

6. Identification of Components Name of Name of Manufacturer National, Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code- -

or Installed Stamped (Yes / No)

-U 1: WO Task 67: Weld #

RC Hot Leg 12" B&W None None 2-53A-10-1OA 2008 Corrected No Decay Heat Nozzle butt weld 2: WO Task 85:

Pzr 11/2" Alloy B&W None None None 1974 Removed No 600 thermowell WO Task 85:

Pzr 11/2" Alloy WSI 105401-TW-01 None 2-RC-TW-0305 2008 Installed No 600 thermowell 3: WO Task 86:

Pzr 1" Alloy 600 B&W None None None 1974 Removed No vent nozzle WO Task 86:

Pzr 1V SS vent WSI 105401-VN-01 None None 2008 Installed No.

nozzle WO Task 63:

DPCo. None None None 2008 Installed No Piping J. J. .1. 6~4 4, ________ 4 _____

4. WO Task 18:

Pzr water sample B&W None None None 1974 Removed No nozzle safe-end

4. I 4~ 4. .~ 4. 1-WO Task 18:

Pzr water sample WSI 105401-SE-01 None None 2008 Installed No-nozzle safe-end WO Pipe Task 79: .. DPCo. None None - None 2008 Installed .. - No...

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet W 01742572 2 of 5 0 6. Identification of Components (continued):

Name of Name of Manufacturer National Other Identification Year Corrected, ASME Component Manufacturer Serial Number Board No. Built Removed, Code or Installed Stamped (Yes / No)

5. WO Task 56:

Pzr level tap nozzl B&W saf-endValveNone None By Instrument 2-RC-IV-Root162 1974 Removed No nozzle safe-end ______

WO Task 56: By Instrument Root Pzr level tap nozzl WSI 105401-SE-03 saf-endValve None 2-RC-IV- 162 2008 Installed No

  • nozzle safe-end
6. WO Task 57: By Instrument Root Pzr level tap B&W None None Valve 2-RC-IVu-163 1974 Removed No nozzle safe-end Vave_2-RC-IV_163 WO Task 57: By Instrument Root Pzr level tap WSI 105401-SE-02 None Valve 2-RC-IV-163 2008 Installed No nozzle safe-end
7. WO Task 40:

2RC-LT-0005P1 Kerotest EC20-14 None 2RC-IV-164 UNK Removed No IRV WOTask 58: By Instrument Root Pzr level tap B&W None None Valve 2-RC-IV-164 1974 Removed No nozzle safe-end WO Task 58: By Instrument Root Pzr level tap WSI 105401-SE-07 None Valve 2-RC-IV-164 2008 Installed No nozzle safe-end -

WO Task 75: S/N 46BKM 2RC-LT-0005P 1 Flowserve S/N 46BKM None 2RC-IV-164 2008 Installed No IRV (UTC 1905113)

8. WO Task 50: Anderson -

2RC-LT-0004P3 Greenwood NA None 2-RC-IV-165 UNK Removed No IRV WO Task 59: By Instrument Root Pzr level tap B&W None None Valve 2-RC-IV- 165 1974 Removed No nozzle, safe-end 2-RC-IV- 165 WO Task 59:

Pzr level tap WSI 105401-SE-04 None By Instrument Root 2008 Installed No nozzle safe-end Valve 2-RC-IV-165

9. WO Task 52 IRV for Kerotest EB-20-20 None 2-RC-IV- 166 UNK Removed No 2RC LT0O4P2 WO Task 68:

Pzrleveltap B&W None None By Instrument Root i974 Removed No nozzle safe-end2-RC-IV-166--

WO Task 68: .ByInstrument Root Pzr level nozzle tap safe-end2-RC-IV-166 WSI . 105401-SE-06 - None- Valvet-R6 2008 Installed No nozl saf-ed. - ..- -_.....-. -_ __.---- - --- -- - ____

-D

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI Work Order Number Sheet W 01742572 1 3 of 5

6. Identification of Components (continued):

Name of Name of Manufacturer National Other Identification Year Corrected, ASME Component Manufacturer Serial Number Board No. Built Removed, Code or Installed Stamped (Yes / No)

10. WO Task 53:

IRV for Flowserve EB 14-9 None 2-RC-IV-167 UNK Removed No 2RC LT0004P I WO Task 71: By Instrument Root Pzr level tap nozzl B&W saf-endValveNone None Vl IrCment 2-RC-IV- 167 1974 Removed No nozzle safe-end_______

WO Task 71: By Instrument Root Pzr level tap WSI 105401-SE-05 None Valve 2IRCumVe 167 2008 Installed No nozzle safe-end I I 167

7. Description of Work
1. ONS Unit 2 Hot Leg 12" Decay Heat Nozzle Butt Welds: EC 94347 covers the original Alloy 600 (82/182) weld material between A-105 Gr. II Nozzle and A-376 Gr TP316 Pipe with a full structural Alloy 52M weld overlay. The weld overlay was installed by WO 01742572 Task 67.
2. ONS Unit 2 Pressurizer 1V2" Thermowell: EC 94347 replaces the original Alloy 600 thermowell and internal Alloy 600 (82/182) weld material J-weld between thermowell and the SA-516 Gr. 70 pressurizer shell with a new Alloy 690 thermowell and an Alloy 52M weld pad on the outside surface of the pressurizer shell. The existing thermowell-was removedt and the replacement thermowell was installed by WO 01742572 Task 85. i
3. ONS Unit 2 Pressurizer 1" vent nozzle: EC 94347 replaces the original Alloy 600 vent nozzle and internal J-weld with a SA-479 Type 316 nozzle and an ER309/309L and ER316/316L weld pad on the surface of the SA-516 Gr. 70 pressurizer head. The vent nozzle replacement includes the following:
a. WO 01742572 Task 62 removed the vent line piping attached to the existing vent nozzle. This piping was then re-installed by WO 01742572 Task 63.
b. WO 01742572 Task 86 removed the existing vent nozzle and installed the replacement vent nozzle.
b. WO 01742572 Task 63 re-installed the vent line piping. This installation includes the addition of one (1) Class "A" 6000# SA-'182 Gr. F316 full coupling in the pressurizer 1-inch SA-376 TP 316 vent line, to facilitate the piping restoration.
4. ONS Unit 2 Pressurizer 1F water sample nozzle safe-end: EC 94347 replaces the original Alloy 600 safe-end and Alloy 600 (82/182) weld material between safe-end and A-508 CL I nozzle with a SA-479 type 316 safe-end and ER309/309L weld material. The sample tap safe-end replacement includes the following:
a. WO 01742572 Task 54 removed the sample line between theexisting safe-end and 2RC-16. This piping was then re-installed by WO 01742572 Task 79.
b. WO 01742572 Task 18 removed the existing safe-end and installed the replacement safe-end.

c.- WO 01742572 Task 79 re-installed the sample line piping. This iristallation includes the addition of one (l)'Class"A" 6000# SA-182 Gr. F316 1-inch full coupling to connect the new safe-end to the existing 1-inch SA-376 TP 316

...... sample piping, and one (1).Class "B" 6000# SA-182 Gr. F316 V2-inch full coupling- to-reconnect the piping -.....

downstream of valve 2RC-16, to facilitate the piping restoration.

5. ONS Unit 2 Pressurizer 1" level tap nozzle safe-end (associated with 2RC-IV-0162): EC 94347 replaces the original Alloy.

.. 600 safe-end and Alloy 600 (82/182) weld material between safe-end and A-508 CL 1 nozzle with a SA-479 tyrpe 316 safe-

........ end and ER3091309L. weld material. The safe-end replacement includes the following: .

a. WO 01742572-Task 47 removed 2-RV-IV-0162. This valve was then re-installed by WO 01742572 Task 7-3..
b. WO 01742572 Task 56 removed the existing safe-end and installed the new replacement safe-endd.
c. WO 01742572 Task 73 re-installed 2-RV-IV-0162.

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01742572 4 of 5

7. Description of Work (continued):
6. ONS Unit 2 Pressurizer 1" level tap nozzle safe-end (associated with 2RC-IV-0163): EC 94347 replaces the original Alloy 600 safe-end and Alloy 600 (82/182) weld material between safe-end and A-508 CL 1 nozzle with a SA-479 type 316 safe-end and ER309/309L weld material. The safe-end replacement includes the following:

a, WO 01742572 Task 48 removed 2-RV-IV-0163. This valve was then re-installed by WO 01742572 Task 74.

b. WO 01742572 Task 57 removed the existing safe-end and installed the new replacement safe-end'.

c, WO 01742572 Task 74 re-installed 2-RV-IV-0163.

7. ONS Unit 2 Pressurizer 1" level tap nozzle safe-end (associated with 2RC-IV-0164): EC 94347 replaces the original Alloy 600 safe-end and Alloy 600 (82/182) weld material between safe-end and A-508 CL I nozzle with a SA-479 type 316 safe-end and ER309/309L weld material. The safe-end replacement includes the following:
a. WO 01742572 Task 49 removed 2-RV-IV-0164. The existing valve was found to be inoperable.
b. WO 01742572 Task 58 removed the existing safe-end and installed the new replacement safe-end.
c. WO 01742572 Task 75 installed a new different type valve to replace 2-RV-IV-0164.
8. ONS Unit 2 Pressurizer 1"level tap nozzle safe-end (associated with 2RC-IV-0165): EC 94347 replaces the original Alloy 600 safe-end and Alloy 600 (82/182) weld material between safe-end and A-508 CL I nozzle with a SA-479 type 316 safe-end and ER309/309L weld material. The safe-end replacement includes the following:
a. WO 01742572 Task 50 removed the existing 2-RV-IV-0165. This valve was discarded, as OE200633/EC 90764 is replacing this root valve with a different type valve.
b. WO 01742572 Task 59 removed the existing safe-end and installed the new replacement safe-end.
c. WO 01677233 Task 01 installed the new replacement 2-RV-IV-0165, per OE200633/EC 90764. This is listed here only for information, the valve installation is not included in the WO 01742572 NIS-2.
9. ONS Unit 2 Pressurizer 1" level tap nozzle safe-end (associated with 2RC-IV-0166): EC 94347 replaces the original Alloy 600 safe-end and Alloy 600 (82/182) weld material between safe-end and A-508 CL I nozzle with a SA-479 type 316 safe-end and ER309/309L weld material. The safe-end replacement includes the following:
a. WO 01742572 Task 52 removed the existing 2-RV-IV-0166. This valve was discarded, as OE200413/EC 80244 is replacing this root valve with a different type valve.
b. WO 01742572 Task 68 removed the existing safe-end and installed the new replacement safe-end.
c. WO 01660818 Task 01 installed the new replacement 2-RV-IV-0166, per OE200413/EC 80244. This is listed here only for information, the valve installation is not included in the WO 01742572 NIS-2.
10. ONS Unit 2 Pressurizer 1" level tap nozzle safe-end (associated with 2RC-IV-0167): EC 94347 replaces the original Alloy 600 safe-end and Alloy 600 (82/182) weld material between safe-end and A-508 CL 1 nozzle with a SA-479 type 316 safe-end and ER309/309L, weld material. The safe-end replacement includes the following:
a. WO 01742572 Task 53 removed the existing 2-RV-IV-0167. This valve was discarded, as OE200413/EC 80244 is replacing this root valve with a different type valve.
b. WO 01742572 Task 71 removed the existing safe-end and installed the new replacement safe-end.
c. WO 01660818 Task 04 installed the new replacement 2-RV-IV-0167, per0E200413/EC 80244. This is listed here only for information, the valve installation is not included in the WO 01742572 NIS-2.
8. Test Conducted LE] Hydrostatic - Pneumati~c 0 Nominal Operating Pressure L Exempt D Other Pressure PSI Test Temperature OF.

I.

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet W 01742572 1 5 of 5

9. Remarks (Applicable Manufacturer's Data Reports to be attached)
1. Decay Heat Nozzle Weld Overlay - See WSI Traveler 105401-TR-006 in WO 01742572 Task 6.
2. Replacement Pressurizer Thermowell - See WSI Certification Report 105401-ONS-U2, QA-1 Fabricated Components.
3. Replacement Pressurizer Vent Nozzle - See WSI Certification Report 105401-ONS-U2, QA-I Fabricated Components.
4. Replacement 1" Pzr water sample nozzle safe-end - See WSI Cert. Report 105401-ONS-U2, QA-I Fabricated Components.
5. Replacement 1" Pzr level tap nozzle safe-end - See WSI Certification Report 105401-ONS-U2, QA-1 Fabricated Components.
6. Replacement 1" Pzr level tap nozzle safe-end - See WSI Certification Report 105401-ONS-U2, QA-1 Fabricated Components.
7. Replacement 1" Pzr level tap nozzle safe-end - See WSI Certification Report 105401-ONS-U2, QA-1 Fabricated Components.
8. Replacement 1" Pzr level tap nozzle safe-end - See WSI Certification Report 105401-ONS-U2, QA-1 Fabricated Components.
9. Replacement 1" Pzr level tap nozzle safe-end - See WSI Certification Report 105401-ONS-U2, QA-1 Fabricated Components.
10. Replacement 1" Pzr level tap nozzle safe-end - See WSI Certification Report 105401-ONS-U2, QA-1 Fabricated Components.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed L. S. White, Engineer Date 11-26-08 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of.,A,_a~erI Z__,,Z.x._AJAq and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owners Report during the period Z- Z 7 - o& to -/ ?- 07 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

-Commissions AJC/<1i4f

'-" - Inspector's Signature National Board, State, Province, and Endorsements Date

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number-* Sheet 01742572, 01677233 I of 2 w 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/25/08

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

D 2RC-IV-0 165 AGCO unknown unknown unknown unk Removed NO 2RC-IV-0165 Flowserve 52BKM 2057 UTC1913505 2008 Installed YES

7. Description of Work R.eplace__,_ Class A instrument root valve 2RC-IV.-0165_

-8. TestC Conrduicted-ElyrstatiC. Eli .neum-atic Z Nominal Operaiing Pressure.-. Exempt -- Other Pressure PSI Test Temperature OF

-- I I

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number - Sheet 01742572, 01677233 I 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0

0 o

0 0

CERTIFICATE OF COMPLIANCE

.Icertify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed

  • 4*g~x J Jennifer Barrett, Mechanical Engineer Date 11/25/2008 LT & Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and employed by HSB CT of -- Hartford; -Connecticut - - - -- have-inspected the components described in this Owner's Report during the period /0 -Z~S - o, to /.. 0..7 . ,and state that to the- best of -my -knowledge --and---belief -- the---Owner has--performed -examinations and taken corrective- measures--

described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By..signi ng- this. -certificate-neitheL-,the.Inspector_ nor-his-employe rmakes -any. warranty,, expressed or implied,-

ý-d6n-c-&iiri§ thWxri tiOh'R-ir' urhroe heitter thf Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any

-kind arising f rom- or connected-with-this -inspection._--- ----

7 C6rnrnissions~VC >'~%'A~-

0 Date

'&4-7

-'Thspector'sSignature- - National Board; State, Province, and Endorsements U-

Form NIS-2 Owner's Report for Repair/Replacement Activity i

As required by the provisions of the ASME Code Section XI I.

Work Order Number - Sheet 01742572, 01660818 I of 2

1. Owner 2. Plant Unit Duke Power Company 526 South Church Street Oconee Nuclear Station 7800 Rochester Hwy j Date ONS - 2 Charlotte, NC 28201-1006 Seneca, SC 29672 11/25/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed. Stamped (Yes I No) 2RC-IV-0166 Kerotest EB-20-20 3296 unknown 1974 Removed YES 2RC-IV-0166 Flowserve 53BKM 2058 UTC1913506 2008 Installed YES 2RC-IV-0167 Kerotest EB 14-9 3364 unknown 1974 Removed YES 2RC-IV-0167 Flowserve 48BKM 2054 UTC 1913502 2008 Installed YES
7. Description of Work Replace I", Class A instrument root valves 2RC-IV-0 166 and 2RC-IV -0167
8. Test Conducted ....

Eli Hydrostatic E] Pneumatic L- Nominal Operating Pressure L Exempt N Other Functional Leak Ins.

Pressure PSI Test Temperature _F

Forth NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I

Work Order Number -, Sheet 01742572, 01660818 2 of 2 9 emarks (Applicable Manufacturer's Data Reports to be attached) 0 0

0 0

0 0

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed

  • I 4 Jennifer Barrett, Mechanical Engineer Date 1/13/2009 U I/ Owner or Owner's Designee, .Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,_1.*r/' o and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period __ 0- Z_3__O-f_ to /- -o 7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements ofthe ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report.-- Furthermore, neitheT-the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions 4/C-/'*'A--A', C.

- 'Inspector's Signature Nationa-lBoard, State, Province, and Endorsements Date /-/ o 7

C-Form NIS-2 Owner's Report for Repair/Replacement Activities As- required by thelfoV-0n9isSbfthe&ASME Code Section XI Wock Order Numbt Sheet 01762706 Pagel of 2 1.owner Duke Power Company 2. Plant Oconee Nuclear Station nunit 526 South Church Street 7-800 Rochester Hwyt 1 /

Charlotte, NC 28201-1006 Seneca, SC 29672-0752 . D

3. Work Performed. By rype Code.. Symbol Stamp Duke Power Company

... ...... I Noft-Applicable Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiraton Date 'Not Applicable

4. Identification of Syt.,*. A.MF r.I..

High Pressure Injection - High Pressure Portion , ASME Class I 5.

(a) Applicable Construction Cod USAS B31.1 1967: Edition, No Addenda No Code Case (b) Applicable Edition Section XIUtilized For R/R Activity 1998: Edition, 2000 Addenda (c) Applicable Section Xi Codes Cases(s) None

6. Identification of Coimponents Name of Component Manufacturer: Manufacturer National Other Year Corrected, ASME Code Serial Number Board No identification Built Removed or Stamped Installed (Yes/No)

(1) 2-51A-0-1479E-H1E, Weld- N/A N/A UNK N/A UNK Removed No material 2-51A-O-1479E-H1E, Weld material N/A N/A UNK UTC UNK Installed No 1915691 2-51A-0-1479E-H1 E, Weld material UNK UTC UNK Installed No 1898596

7. Description of Work Removed existing weld, beveled existing plate and reinstalled plate.
8. Test Conducted F-1 Hydrostatic El Pnuematic El Nominal Operating Pressure LI Excempt [ Other Visual Pressure PSI Test Temperature Deg. F

Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisio'ns of the ASME Code SectionXl work.Order Numbe . Shee

-- .. 01752706 - 01 . Page2of2

7. Remarks (Applicable Manufactuerr's Data Reports to be attachedi)-

(1) Removed existing weld, beveled existing plate'and reinstalled plate.

CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp Not Applicable Certificate of A therization Number Not Applicable Expiration Date Not Applicable Signed / f4*$> ./

& dtM, Date __. ________

Owner or Owner's Designee. Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of ,Jo,,e' , . and employed by HSB CT of Hartford. Connecticut have inspected the components described in the Owner's Report during the period 3. .y- o* to i o,*. oP , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the-inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.

________________ Commision(s) -/W Inspector's Signature National Board. State. Province. and Endorsements Date

Form NIS-2 Owner's Report for Repair/Replacement Activity cIL As required by the provisions of the ASME Code Section XI Work Order Number Sheet aI v

01762590 Unit 1 of 2

1. Owner 2. Plant Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/10/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class RC, ASME Class 1
5. . ..

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section X1 Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer' National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 1.) 2-50-0-RCPM-H6606 DPCo None None None IJNK Corrected NO I I 4 4 4
7. Description of Work OE201906 (EC95380); S/R 2-50-RCPM-H6606 - Temporarily remove and reinstall with additional shims.

T I8a Cdneumttic ominaOperating Pressure -kN Exempt rOther Pressure PSI Test Temperature OF .

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Sheet I

Work Order Number a 01762590 2 of 2 1W.

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

I o 2-50-RCPM-H6606; 1/4", 1/2", 3/4", 1" and 1 1/2" plates used as shims were installed..,(

§

  • Y4",'*e. U,.C.. \ ,: S x o -l P ("*C o 8-78' I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

T ype C ode Symbol S tamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date -Not Applicable Signed -Date /.-/o-4 o SOwneion e ee, Title I CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .-4 t,W (-5V, -,ee and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 3-,1-,06 to /.-c?-o7' ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

-B-y signing this certificate nreithertheInspectornor his employer makes any warranty, expressed or implied,

ýconc erningthe examinati-n d-corrective"measuresýdescribedin this Owner's-Report. Furthermore, neither the',

Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising-from or.connected-with-this .inspection.... ..

____________________ Commissions _ _ _ _ _ _ _ _ _ _ _

Inspectors. lgnature .. =-. National Board, State, P'rovince, and Endorsements Date..... Z

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01762592 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/9/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class RC, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For RFR Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 1.) 2-50-0-1066A- DPCo None None None LUNK Corrected NO RCPM-2B 1-SS1 2.) 2-50-0-1066A- DPCo None None None LINK Corrected NO RCPM-2B 1-SS2 3.) 2-50-0-1066A- DPCo None None None LINK Corrected NO RCPM-2B 1-SS3
7. Description of Work OE201907 (EC95381); Modify snubber extension pieces for S/Rs 2-50-0-1066A-RCPM-2B1-SS1, SS2 and SS3 to extend pin to pin length to provide greater flexibility in their reinstallation due to RCPM 2B13 replacement.
8. Test Conducted D Hydrostatic l Pneumatic [-i Nominal Operating Pressure L Exempt ] Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01762592 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 2-50-0-1066A-RCPM-2B 1-SS 1; 1/2" & 1 1/2" plates, 2 Anvil snubber rear brackets and snubber extension assembly, Anvil sway strut assembly with additional rear bracket.

@ 2-50-0-1066A-RCPM-2BI-SS2; 1 1/2" plates, 6" pipe, 2 Anvil snubber rear brackets and snubber extension assembly.

O 2-50-0-1066A-RCPM-2B 1-SS3; 1 1/2" plates, Anvil snubber rear bracket and snubber extension assembly.

0 0

0 0

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed // '* ?Z,/ Date I q/9/10oo ow er o wner' esignee, noitle CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of o and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 3- "/'- , to /-___;X-o 2'? , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions AJ C Inspector's Signature National Board, State, Province, and Endorsements Date -? -' '

Form NIS-2 Owner's Report for Repair/Replacement Activity 0.

As required by the provisions of the ASME Code Section XI U.

Work Order Number

! Sheet 01762594 I of 2 I.

'qK 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/10/2008

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class RC, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of ' Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed -Stamped

.(Yes I No) 1.) 2-50-0-1066A- DPCo None None None UNK Corrected NO RCPM-2B2-SS2 2.) 2-50-0-1066A- DPCo None None None UNK Corrected NO RCPM-SS3

___ I ___ I ___ I

___ I _ .1 1

__________________________ I I _______________________ _____________________ I ________________________ I ~ I __________________ I

7. Description of Work OE201909 (EC95382); Modify snubber extension pieces for S/Rs 2-50-0-1066A-RCPM-2B2-SS2 and -SS3 to extend pin to pin length to provide greater flexibility in their reinstallation.
8. Test Conducted E] Hydrostatic LI Pneumatic L- Nominal Operating Pressure Z Exempt [-] Other .....

Pressure PSI Test Temperature OF

Form' NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I

Work Order Number Sheet 01762594 2 of 2 I

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o 2-50-0-1066A-RCPM-2B2-SS2; 1 1/2" plates, Anvil snubber rear bracket and snubber extension assembly.

O 2-50-0-1066A-RCPM-2B2-SS3; 1 1/2" plates, Anvil snubber rear bracket and snubber extension assembly.

0 0

0 e

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed .Date //-j o-05 OwneorOOw sDesD ee, Title F ,-

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,,e,., , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,-,2-o8 to ,__-.,-" _7_ , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions ,/ ,

--T-nspector's Signature National Board, State, Province, and Endorsements Date I

.Form NIS-2 Owner's Report for Repair/Replacement Activity C As required by the provisions of the ASME Code Section XI U-Work Order Number I Sheet 01765542 I of 3

-U -

1 S MW.1 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/1/2007

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class High Pressure Injection (HPI), ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected,- ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code-or Installed Stamped (Yes I No)

Addt'l weld material to base of the vent/drains containing the valves listed below:

2HP-322 NA NA NA NA NA Corrected NO 2HP-323 NA NA NA NA NA Corrected NO 2HP-326 NA NA NA NA NA Corrected NO 2HP-327 NA NA NA NA NA Corrected NO 2HP-334 NA NA NA NA NA Corrected NO 2HP-345 NA NA .. .. NA NA NA Corrected_ NO

. . ... ... . . . .. i . . . . .. .. . .. . . .. . . .. . .. i . .. .. . . . .. . . .. .. . . . .. ...--

7. Description of Work WORK ORDER NUMBER 01765542 SHEET 2 of 3 Add 2-to-I taper welds to base (i.e., connection of the 1" line to the half-coupling on the 2 1/2" HPI header) of the vent/drains containing the valves listed below:

- 2HP-322

- 2HP-323

- 2HP-326

- 2HP-327

- 2HP-334

- 2HP-345 This preventative work is required as an extend of condition item due the 2HP-487 leak (ref. PIP 0-07-02844). Addition of 2-to-I taper welds provides better vibrational resistance.

8. Test Conducted

-- Hydrostatic E- Pneumatic L Nominal Operating Pressure L-I Exempt Other O None Pressure PSI, Test Temperature OF

,0 ., : I Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01765542 3 of 3

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0

0 Q

0 Q)

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp NotApplicable Certificate of Authorization Number Not AWlipable Expiration Date Not Applicable Signed Geart eDate 11/1/2007 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of , , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period //- d'- >7 to .-.- 05' , and state that to the best of my knowledge and belief", the Owner has- performdd exarminatiofns- and taken 'Corrective measures described in this Owner's Report in accordance with-the requirements of th-ASME Code, Section Xl.

By signing this certificate neither -the -Inspector-nor his--employer makes any-warranty, expressed or implied, concerning the examinations and corrective--measures -described-in -this Owner's Report. - Furthermore, -neither._the.

Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss..of any, kind arising from or connected with this inspection...._

- *j ..... ........ Commissions- -- ,/S/.,,i,... .

Inspector's Signature .. National Board, State, Province; and Endorsements Date /- ",,-

FoYrm NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI Work Order Numbe Sheet 01786312 - 01 Page I of 2

- ~ Iunit w 1. Owner Duke Power Company 2. Plant Oconee Nuclear Station Unit 2

526 South Church Street 7800 Rochester Hwy Date 12/8/2008 Charlotte, NC 28201-1006 Seneca, SC 29672-0752

3. Work Performed By Type Code Symbol Stamp I Not Applicable N

Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of Systems, ASME Class High Pressure Injection - High Pressure Portion , ASME Class (a) Applicabie Construction Cod USAS E31.7 1969 Edition, No Addenda No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 1998: Edition, 2000 Addenda (c) Applicable Section Xl Codes Cases(s) None
6. Identification of Coirnponents Name of Component Manufacturer: Manufacturer National Other Year Corrected, ASME Code Serial Number Board No identification Built Removed or Stamped Installed (Yes/No)

Addt'l weld material on all socket N/A NA UNK NA UNK Corrected No welds from inlet of valve 2HP-453 to inlet of valve 2HP-246

7. Description of Work ADD 2-TO-1 TAPER WELDS TO ALL SOCKET WELDS STARTING INLET OF VALVE 2HP-453 TO INLET SIDE OF VALVE 2HP-246 This preventative work is required as an extend of condition item due the 2HP-487 leak (ref. PIP 0-07-02844). Addition of 2-to-1 taper welds provides better vibrational resistance.
8. Test Conducted IZ Hydrostatic E] Pnuematic E] Nominal Operating Pressure ED Excempt W Other Visual Pressure PSI Test Temperature Deg. F

Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl Type Code Symbol Stamp Not Applicable Certificate of Autherization Number Not Applicable Expiration Date Not Applicable Signed Geary L. Armentrout, Principal Engineerc__ *-te 12/8/2008 Owner or Owner's Designee, i1tle, CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of and employed by HSB CT of Hartford, Connecticut have inspected the components described in the Owner's Report during the period 6- 5'/-40 to /2 - /-0 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.

~~~~~Commision(s) ,,..le/,l*/je,,0/l.de_

Inspector's Signature National Board, State, Province, and Endorsements Date zlf,6-

Form NIS-2 Owner's Report for Repair/Replacement Activities Ký As required by the provisions of the ASME Code Section XI I.1 Work Order Numbe Sheet 01786312 - 10 Pagel of 2

1. Owner Duke Power Company j 2. Plant Oconee Nuclear Station I I Unit 2

526 South Church Street 7800 Rochester Hwy D Charlotte, NC 28201-1006 Seneca, SC 29672-0752

3. Work Performed By Type Code Symbol Stamp I Not Applicable Duke Power Companyr Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of Systems, ASME Class High Pressure Injection - High Pressure Portion , ASME Class f/

(a) Applicable Construction Cod USAS 831.7 1969 Edition, No Addenda No Code Case (b) Applicable Edition Section XtUtilized For R/R Activity 1998: Edition, 2000 Addenda (c) Applicable Section XlCodes Cases(s) None

6. Identification of Coimponents Name of Component Manufacturer: Manufacturer National Other Year Corrected, ASME Code Serial Number Board No identification Built Removed or Stamped Installed (Yes/No)

Addt'l weld material on all socket N/A NA UNK NA UNK Corrected No welds from inlet of valve 2HP-451 to inlet of valve 2HP-240

7. Description of Work ADD 2-TO-1 TAPER WELDS TO ALL SOCKET WELDS STARTING INLET OF VALVE 2HP-451 TO INLET SIDE OF VALVE 2HP-240
8. Test Conducted

[] Hydrostatic E] Pnuematic LI Nominal Operating Pressure EL Excempt R] Other Visual Pressure PSI Test Temperature Deg. F

Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section X1 Work Order Numbe 01786312 - 10 Page 2 of21 I Sheet 1 7. Remarks (Applicable Manufactuerr's Data Reports to be attached)

CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp Not Applicable Certificate of Autherization Number Not Applicable Expiration Date Not Applicable Signed Geary L. Armentrout, Principal Enginee ,  ;* 'Date 12/8/2008 Owner or Owner's Designee, "itO CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of and employed by HSB CT of Hartford, Connecticut have inspected the components described in the Owner's Report during the period 9---o6 to ,e -f-e* , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.

____________________ Commision(s) ,'_/,V%,A'd_

Inspecor's Signature National Board, State, Province, and Endorsements Date ,e-A#'

(f Form NIS-2 Owner's Report for Repair/Replacemenit Activity I _is-equired bytheprovisions of the ASME Code Section XL -. - -

-Work:OrdeirNuM ber - -Sheet 1 1 798312-0..... I of 2

i. Owner:

Duke Power Company 5-Sut-ur'-fet ~ +/-

rn '-

-.- Qconee Nuclqar Station

-78W0RoeheqterHwy -

j Dt-ONS - 2 Charlotte, NC 2 8201-1006 - .,--Seneca,:SC -296-7 - 1:-,-2-/1/2008

3. Work Performed by .Type Code-Symbol-Stamp.

Not Applicable---* --

Dike Power Comp-ay .. . . Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class Reactor Coolant, ASME Class 1 "5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI CodeCase(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number _ Board No. Identification Built Removed, Code

.. or'Installed Stamped:

(Yes I No) 2RC-68 Consolidated BT-04976 None None 1979 Removed YES 2RC-68 Consolidated BL-08896 None None 1971 Installed YES

7. Description of Work Installed valve, serial number BT-04976, was removed for 1ST Program. Replaced with tested spare valve, serial number BL-08896 from Stock.
8. Test Conducted

[I Hydrostatic L-] Pneumatic E Nominal Operating Pressure 1L: Exempt M Other Visual leak check Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section:X-: '________" ________- __"_'

! 2of 2lU

-: :W 019320 Order -Number--- -Sheet

-9. Rem~ark*.(-Api pcable:M~ii-uractui'-r-rsData*Reportstob .att ehed) ................. . . * . .... ..

O -R*epla-d-cxistfiig- VaVeWit tested SpareF-om stock;--Seral-number-BL-08896. ...... ......

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed _ , Sr. Engineer Date 1.2/1/2008 Oy# -rOwner's esignee, Title CERTIFICATE OF INSERVICE INSPECTION

'I,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,oe ,,j, :and employed by HSB CT of Hartford, Connecticut -have inspected the components described in this Owner's Report during the period 17-J/- c' to /-a. ?-Or__ I and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his erfployer shall be liable in any-manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Sinaue Commissions ~adEdreet Daenspector'sSignature National Board, State, Province, and Endorsements Date / **_ZZ 0,r

Form NIS-2 Owner's Repoirtfor Repair/Replacement Activity

-. Asrr the.provisions of the. ASME Code Section XI.

=. ,

Work Order Number Sheet N/A 1 of 2 I

1.-Owner " - .. -_ -. .- 2.- Plant- . Unit Duke Power Company Oconee Nuclear Station ONS - 2

- 26South-,C-hurch-Street----, . ' - 7800 Rochester, Hwy ..... Date . .

Charlotte, NC 28201-1006 Seneca, SC 29672 12/1/2008

3. Work Performed by Type Code Symbol Stamp Not Applicable

.Duke-Power-Company - . . Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class Reactor Coolant, ASME Class 1
5. ".

(a) Applicable Construction Code: ASME Section III 19 65 Edition, Summer Addenda, No Code Case (b) Applicable. Edition Section X1 Utilized. For R/R Activity . 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected,. ASME Component - Manufacturer :Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No) spare pressurizer Dresser BL-08896 None None 1971 Corrected YES code safety valve
7. Description of Work Replaced disc, installed serial #: ADW13 from stock.
8. Test Conducted .

[l Hydrostatic E--Pneumatic [I] Nominal Operating Pressure E-"Exempt Other visual leak check Pressure PSI Test Temperature °F P., yf 0f g

q Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI

- WorkOrde r Number, ~1 Sheet3 2 -

N/A -

--9w- -Remarks (Applicable Manufacturer's Data Reports to be attachedy --** ----- _-*--*--- ----.------ .-

JO Disc-* aog-ID. UTC#; 1089829, serial'#:--ADW13 . " ..

f'" .... .....

Z??6 0

.... .. .. ,,- /

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number- Not Applicable Expiration Date Not Applicable Signed T S.) =. , Sr. Engineer Date 12/3/2008 S Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A/lor// l and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7-/S-OC to / -Z.._.- 0,' , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__________________________Commissions A ,C4-,"/,4',6C

" -iInspector'sSignature National Board, State, Province, and Endorsements Date /-,? Z-

&~ ~

Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI Work Order Numbe Sheet 01798343 - 02 a 1. Owner Duke Power Company 2. Plant Oconee Nuclear Station Unit Page 1 of 2 2

526 South Church Street 7800 Rochester Hwy Seneca, SC 29672-0752 Date 12/2/2008 Charlotte, NC 28201-1006

3. Work Performed By Type Code Symbol Stamp Not Applicable N

Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of Systems, ASME Class Main Steam , ASME Class 1 5.

(a) Applicable Construction Cod USAS B31.1 1967: Edition, No Addenda No Code Case (b) Applicable Edition Section Xi Utilized For RIR Activity 1998: Edition, 2000 Addenda (c) Applicable Section XI Codes Cases(s) None

6. Identification of Coimponents Name of Component Manufacturer: Manufacturer National Other Year Corrected, ASME Code Serial Number Board No identification Built Removed or Stamped Installed (Yes/No)

(1) 50-0-1481A-H3, Hydraulic Grinnell 18790 UNK N/A UNK Removed No Snubber 50-0-1481A-H3, Hydraulic Snubber Anvil 36971 1 UNK UTC 1908095 UNK Installed No

7. Description of Work Replace existing Grinnell snubber like for like due to seal life.
8. Test Conducted

[] Hydrostatic E] Pnuematic D Nominal Operating Pressure LI Excempt 66 Other Visual P ressure PSI Test Temperature Deg. F

Form'NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI Work Order Numbe _ Sheet 01798343 - 02 Page2of2

7. Remarks (Applicable Manufactuerr's Data Reports to be attached)

Replace existing snubber due to seal life.

CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp Not Applicable Certificate of Autherization Not Applicable Expiration Date Not Applicable Signed _____65_, __r.__ _Date / V X/fý Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of Y and employed by HSB CT of Hartford, Connecticut have inspected the components described in the Owner's Report during the period /a-/ - o0 : to " _/-e- ,,p , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection-Commision(s) /_ * 'v/,,de, Inspector's Signature National Board, State, Province, and Endorsements Date /-1-e 0 7

C/i Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work OrderrNumber -Sheet....

S98-3-76-07--

1. Owner - 2. Plant unit.

Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800,Rochester=Hwy . . .. .. -Date -......

Charlotte, NC 28201-1006 Seneca, SC 29672 12-1-08

3. Work Performed by Type Code Symbol-Stamp - .

Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class Reactor Coolant System, ASME Class 1 (a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 1nlet flange- UNK NONE NONE NONE UNK Corrected NO bolting
7. Description of Work Installed new inlet -tuds and nuts due to spare valve having through hole inlet flange.

AL F'8. Test Conducted Fi Hydrostatic E] Pneumatic 1-- Nominal Operating Pressure [: Exempt E Other RCS Visual Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity

_ As required by the provisions of the ASME Code Section XI wok- . eet.of-2 ...

_ Remarks (Applicable Manufacturer's Data Reports to be attached).. .........-.......  : .

o Inlet stud material - catalog ID 318736- UTC No's: 857853, 857854, 857855 & 951541. Inlet nut material - catalog ID 131853

_-TU7-TC No_-YI922820 ' *'..

0 0 C OF COMPLIANCE 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed Sr. Engineer Date 12/1/2008

- Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of /,6"4 . 6 e and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period // - to /-/7- o7 , and state.that to the best of my knowledge and*belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the' Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

~rQ~ Commissions ___________________-_

- -spector's ;ignature National Board, State, Province, and Endorsements Date /-/f-or

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01799867 I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/17/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class HPI, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 67 Edition, No Addenda, None Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected,- ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed -Stamped (Yes No)

Pipe Duke Energy .... 1970 Installed NO

- s i io fWor --....... .. - _-- .

-.Welding-to-re-install-sect-ion.of-lPI pip-.e . ...

8;.a -Test -COnduUt-d ... . -...

SPena OperatingPressure Exe leak st.

Firesre __ _ _ _PSI Test Temperature OF___

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet I 01799867 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Remove and replaced three welds to support HPI Thermal Sleeve removal and replacement.

0 0

0 Q

4 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Aut~\rzto NmtNoA liable Expiration Date Not Applicable-Signed 6O~ 1 9j Vi6¶ PL &4 CA Date IL lo NOwner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A/lerlv A and employed by HSB CT of Hartford, Connecticut .. . . have inspected the components described in this Owner's Report during the period a- V- 0 6 to /-,,. ,9 , and state that to the best of my knowledge and--belief, the.. Owner- hasprfornmd.examinatio*nls ae*aken corrective measuresl described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl. .

By signing this certificate neitfer the_ýnsp-tor n--his- eployer~makes-any_-warranty, expressed or- implied, concerning the examinations and corrective measures descdbed-in_-this-_Owner's-Report. Furthermore, neiather th_e

-Inspector nor his employer-shall be-liable in any manner-for any personal injury or property damage or-a loss of any

.kind arising from or connected with this-inspection .-..-. . ..-..-....-.......-

--- _T

  • . .... rift

. .o.mmissio A -AfC .s / 9..... . .c.

Inspector's Signaýire_ National Board, State, Province, and Endorsements Date /'iŽ-"* 7 "

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01799868 I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/17/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class HPI, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 67 Edition, No Addenda, None Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) Noneý

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. .Identification Built Removed;, Code or Installed [ Stamped (Yes I No)

Pipe Duke Energy 1970 Installed NO 7.-Description of-W ork . . .. ..... ........... .. . ..-.... ... .... .

Welding to rere-install.

.W sectioniiof HPI s ag~~~~~~to~

ei ldin l-et-of H-i pipe....--.-

e ... . .............. .... .. ... .......-.. . . . . . . ........ .............. . ... . . . .

0. -

I-lst ,eonauctea - - -. . ---.-

[]Hdrotatc UPnematc L] Noinalx Oper-at4Ping  ;`_uD-1]Eiempt -0 Othe yse la f_

-PSL. - .,esItempiatuve.-_ "

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number _ Sheet

-3

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

I 01799868 2 of 2 0 Remove and replaced three welds to support HPI Thermal Sleeve removal and replacement.

0 0

0 0

0 0

0 CERTIFICATE OF COMPUANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Cetiatteofoýn Number No Apicableý Expiration Date Not Applicable Signed ________________Date __________

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A v,,,e_4 and-employed by HSB Cr of ...... Hatford, Connecticut - have inspected the components described in this Owner's Report during the period -... - -. 4 8 to_... _-._- 7_ , and state that to the best of my knowledge and belief, the Owner has performed examinations and tak corrective measures described in this Owners Report in.accordance ASME Code,Section XI.

twitltheirquirementsQ~f-the _ .....

By.signing.thiscertificate neither thejn__specMornor his employer makes any warranty, expressed or impii, conceming the examinations- andrl-corrective -measures - describeini-this-Owner__s Report_-Eu-rmore-fi-eith*r-tho-Inspector nor-his employer-shall be-liable-in-any-mannerifor-anyp-emonal injuryr propertyd amgeora loss of any

-kind arising -from or conneotedwith-this inspeotion.. - - __-.. _-.

anspe of Si -. -  :. -. . -.......... .. Provin.c., a d-Edorsements Board, Stae .. --

'Date ---------- ---- ------

FR Form NIS-2 Owner's Report for Repair/Replacement Activities clii As required by the provisions of the ASME Code Section Xl I.

Work Order Numbe Sheet 01831432 - 30 Page 1 of 2

1. Owner Duke Power Company 2. Plant Oconee Nuclear Station Unit j 2 526 South Church Street 7800 Rochester Hwy Date 1212/2008 Charlotte, NC 28201-1006 Seneca, SC 29672-0752
3. Work Performed By Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of Systems, ASME Class Reactor Coolant , ASME Class 1 5.

(a) Applicable Construction Cod USAS B31.1 1967: Edition, No Addenda No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 1998: Edition, 2000 Addenda (c) Applicable Section Xi Codes Cases(s) None

6. Identification of Coimponents Name of Component Manufacturer: Manufacturer National Other Year Corrected, ASME Code Serial Number Board No identification Built Removed or Stamped Installed (Yes/No)

(1) 50-0-1480A-H8, LoaU0 # N/A N/A UNK N/A UNK Removed No 50-0-1480A-H8, Loa9 Pin Anvil 4 UNK L44I-- UTC UNK Installed No L4NK 1051723

7. Description of Work Replace existing load pin with a double end load stud.
8. Test Conducted D1 Hydrostatic rD Pnuematic Li Nominal Operating Pressure El Excempt W Other Visual Pressure PSI Test Temperature Deg. F

Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI Work Order Numbe .het 01831432- 30 Page2of 2

7. Remarks (Applicable Manuractuerrs Data Reports to be attached)

(1) Replaced existing load pin withdouble end load stud.

CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp Not Applicable Certificate of Autherization Number Not Applicable Expiration Date Not Applicable Signed _- , , Date _ 2/z '

Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of ,)o,,rY , and employed by HSB CT of Hartford, Connecticut have inspected the components described in the Owner's Report during the period /2 -'-c.)? to -/., -00 ,7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.

Comm ision(s) ,4 J/4 C inspector's Signature National Board, State, Province, and Endorsements Date /I O7

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI -------------------------------------

I Work Order NumbeC. ' .Sheet - .

.1838716 lof:2 S

1. Owner .. .2. Plant '. - . Unit . . . .

Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201'1006 Seneca, SC 29672 . 12/8/2008

3. Work Pe'rfo'med by Type Code Symbol Stamp, -

Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class High Pressure Injection System, ASME Class 1 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s)

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)

Piping DPCo N/A N/A None 2008 Installed NO

7. Description of Work Replaced pipe nipple and cap downstream of 2HP-500 due to galled threads 1 8. Test Conducted F-- Hydrostatic EI-] Pneumatic E Nominal Operating Pressure L--Exempt L-- Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI

t. Work Order Number Sheet

-9. Remarks (Applicable Manufacturer's Data Reports to be attached)-,,- -.

I.

..- . *1838716 I 2 of 2

o 1"Pipe nipple: SA376 TP304; 1' Pipe Cap: SA182 F304 0

C-C O F. . . . . . . . . . .

0 0

I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Numbero Applicable Expiration Date Not Applicable Signed Aaron Best, Engineer Date 12/8/2008 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of , , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period //*,.,-o (5 to /-4 9 -- c/i' , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_________________ Commissions /7< AfC

,nspector'sSignature National Board, State, Province, and Endorsements Date / O/f-e9

Form NIS-2 Owner's Report for Repair/Replacement Activity (f_

As required by the provisions of the ASME Code Section XI p I

Work Order Number Sheet 01841935 I of 2

1. Owner .-2. Plant -Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/2/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable.

Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class Reactor Coolant System, ASME Class I 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)
  • Valve 2RC-3 Edwards UNK UNK None UNK Removed NO Valve 2RC-3 Flowserve 06BKB 1976 UTC# 1910056 2008 Installed YES
1) Piping DPCo. None None None 2008 Installed NO
7. Description of Work EC 99776 repaced-valve 2RC-3 and installed a 1/2" full coupling (in order to purge piping for welding).

a8. Test Conducted D Hydrostatic ,"] Pneumatic Z Nominal Operating Pressure D--Exempt [D] Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01841935 2 of 2

9. Remarks-(Applicable Manufacturer's -Data-Reports-to be attached) .

O Installed 1/2" full coupling.

0 0,

CERTIFICATE OF COMPLIANCE of the I cetfy that the statements made in the report are correct and that this conforms to the requirements JASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed Sr Technical Specialist Date 12/3/2008 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,/'o.eLr,, LzeV Z.,.,, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period //- /f,- 0d to /- .2.-,7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither, the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

________________________Commissions '*/" ' *iA'd.

Inspector's Signature National Board, State, Province, and Endorsements Date -

. r Forrn NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1843116-06 I of 2

'1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/6/2009

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Unit 2 2A1 Reactor Coolant System, ASME Class I 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, - -ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed - -Stamped (Yes I No)

ON2RCPU0001 Bingham UNK UNK UNK LUNK Corrected NO

-T.Desitdpntidoii df -oiW---

-Base.material wassused toý weld_ repair a vertical pipe stub within the bowl of the 2A1 RCP during the 2EOC23 e.* _--

-8.-Test-Conducted - -

. jjlydro-s-tatic ." Pneumatic [Nominal Operating Pressure ___Exempt _'__Other_____"

Pressure PSI Test Temperature OF

-Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 11 QA'21 1 A I rz, I l OtIJL LU '- '-' '.

. Remarks (Applicable Manufacturer's Data Reports to be attached) o UTC#0001913772, ELECTRODE, WELDING, 316L, SS, 3/32" DIA X 36" LG 0

0 0

0 o

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.

Type Code Symbol Stamp Not Applicable Certificate of Autho zL *on Number Not Applicable Expiration Date Not Applicable Signed ,"- /-4 *.,* , Associate Engineer Date 1/6/2009 0 nor Owner's De gnee, Title I U CERTIFICATE.OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,ibr,,' c*,b4-,,,, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period //- z/-,' to -,62 - of' , and state that to.-the,,lbest.oft.,ny,.knowledge..and..beliefJhe-O.wraerhas-performed examinations and taken corrective measures described in this Owner's Rep~ortin a-c.crda-n-e-wi~th-the_-re-quLrerm*_nrtsisfth-ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied,

-6o6,erdgi 6he-.examiIti .ons a-nd 'ci'rectiv'd eas*u*skd6ecri-ed' thiisOwners'. Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind:arising from:-or connected with. this-r-n. ,ction-.-----'- . .- -.-

Commison

-`tmpector's Signature National Board, State, Province, and Endorsements

ýDate -

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI U

I Work Order Number Sheet 1731948 1 of 6 m

  • I1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/2/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number

'I- 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No) 2LPSW-228 CRANE UNK UNK NONE LINK Removed NO BNL 2LPSW-228 BN R A070815-4-10 UNK UTC# 1901700 2007 Installed YES INDUSTRIES 2LPSW-229 CRANE UNK UNK NONE UNK Removed NO BNL 2LPSW-229 INDUSTRIES A070815-4-11 UNK UTC# 1901701 2007 Installed YES 2LPSW-90 CRANE UNK UNK NONE UNK Removed NO 2LPSW-90 INDUSTRIES "NS A070815-4-7 UNK UTC# 1901697 2007 Installed YES 2LPSW-92 CRANE UNK UNK NONE UNK Removed NO 2LPSW-92 BNL ýA070815-4-12 UNK UTC# 1901702 2007 Installed YES INDUSTRIES PIPE DPCo. NONE NONE NONE 2008 Installed NO
7. Description of Work EC92500 (OD201184) replaces 3" or smaller carbon steel pipe and components associated with the 2A2 Reactor Coolant Pump Motor Air Cooler and Upper Bearing Oil Cooler with stainless steel piping and components.
8. Test Conducted Hydrostatic Pneumatic E--]Nominal Operating Pressure L-' Exempt [L] Other Pressure 425 PSI Test Temperature * ,F -

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1731948 2 of 6 Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/2/2008

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of.System, ASME Class Low Pressure Service Water, ASME Class 2 5.

(a) Applicable Construction Code: USAS B331.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section X1 Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) i1/2" THERD 1/RO2HD UNK UNK UNK UNK UNK Removed NO R D 1/2" THRD UNK UNK LINK UTC# 1847391 UNK Installed NO ROD 1/2" HEAVY UNK UNK UNK UNK LINK Removed NO HEX NUTS 1/2" HEAVY IUNK UNK UTC# 1901397 LINK Installed NO HEX NUTS 1/2" 1/2 6 UNK UNK UNK UNK UNK Removed WASHER(16) NO 1/2" 1/2 6 UNK UNK UNK UTC# 1901398 LINK Installed WASHER(16) NO 3/4 2 UNK UNK UNK UNK UNK WASHER(32) Removed NO 3/4" 3/4 2 UNK UNK UNK UTC# 1901396 LINK Installed WASHER(32) NO 3/4" THRD UNK UNK UNK UNK UNK Removed NO ROD 3/4" THRD UNK UNK lINK UTC# 1911000 UNK Installed NO ROD 3/4" HEAVY HEX NUTS UNK UNK UNK LINK UNK Removed NO (79) 3/4" HEAVY HEX NUTS UNK UNK UNK UTC# 1897749 UNK ,Installed NO (32) 1

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet W9. Remarks (Applicable Manufacturer's Data Reports to be attached)

I 1731948 3 of 6 o PIPE, 3", SS, ASME SA312, TP304, SCH 40, ANSI B36.10, ASME SECTION III SUBSECTION NC O PIPE, 5", SS, ASME SA312, TP304, SCH 40, ANSI B36. 10, ASME SECTION III SUBSECTION NC O FLANGE, PIPE, WELD NECK, 3", SS, ASME SA182, F304, RAISED, 150 LB, SCH 40, ANSI B 16.5, ASME SECTION III SUBSECTION NC o FLANGE, PIPE, WELD NECK, 5", SS, ASME SA182, F304, RAISED, 150 LB, SCH 40, ANSI B 16.5, ASME SECTION III SUBSECTION NC O FLANGE, PIPE, WELD NECK REDUCING, 5" X 3", SS, ASME SA182, F304, RAISED, 150 LB, SCH 40, ANSI B 16.5, ASME SECTION III

@ TEE, PIPE REDUCER, 5" X 5" X 3", SS, ASME SA403, WP304, BW, SCH 40, ANSI B 16.9, ASME SECTION III O ROD, THREADED, 1/2", 13 UNC-2A, ALLOY STL, ASME SA193 GR B7, ASME SECTION III SUBSECTION NB O ROD, THREADED, 3/4", 10 UNC-2A, ALLOY STL, ASME SA193 GR B7, ASME SECTION III SUBSECTION NB Q NUT, HEX, HEAVY HEX, 1/2", 13 UNC-2B, CARBON STL, ASME SA194 GR 2H, ANSI B 18.2.2, ASME SECTION III SUBSECTION NB

() NUT, HEX, HEAVY HEX, 3/4", 10 UNC-2B, ALLOY STL, ASME SA194 GR 7, ANSI B 18.2.2, ASME SECTION III SUBSECTION NB CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed ____ __ _ __ __ _, _ __ _Date i[ ([o0 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A1,1 '* ,,, u.4J and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Y-d- 08 to / O , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_ _ _ _ _ _ _ _ _ _ _ Commissions ,_____/__ ____J__________

Inspector's Signature National Board, State, Province, and Endorsements Date /_ _7-_ _ I__-_

Form NIS-2 Owner's Report for Repair/Replacement Activity Xs required by the provisions of the ASME Code Section XI Work Order Number Sheet A

1731948 4 of 6 m 9

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/2/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 2 5.

(a) Applicable Construction Code: USAS B331.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section X1 Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year, Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No) 3/4" HEX 3 HEAVY NVTS UNK UNK UNK UTC# 1822335 UNK Installed HX N U E TS (32 )1 NO 3/4" HEAVY HEX UNK UNK UNK UTC# 1912344 UNK Installed HEX NUTS (32) NO 5/8" 5/8 1INK UNK UNK UNK IJNK Removed WASHER(108) NO 5/8" UNK UNK UNK UTC# 1899223 UNK WASHER(108) Installed NO 5/8' HEAVY UNK UNK UNK UNK UNK Removed NO HEX NUTS 5/8" HEAVY UNK UNK UNK UTC# 1834698 UNK Installed NO HEX NUTS 5/8" THRD ROD UNK UNK UNK UNK LINK Removed- NO 5/8" THRD ROD UNK UNK UNK UTC# 1910103 UNK Installed NO 5/8" THRD ROD UNK UNK UNK UTC# 1909601 UNK Installed NO
7. Description of Work EC92500 (OD201184) replaces 3" or smaller carbon steel pipe and components associated with the 2A2 Reactor Coolant Pump Motor Air Cooler and Upper Bearing Oil Cooler with stainless steel piping and components.
8. Test Conducted L- Hydrostatic [I Pneumatic [:] Nominal Operating Pressure [Z Exempt E] Other Pressure PSI Test Temperature OF "

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI U

Work Order Number Sheet 1731948 5 of 6 U a F1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/2/2008

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class LOW PRESSURE SERVICE WATER, ASME Class 2 5.

(a) Applicable Construction Code: USAS B331.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed - Stamped (Yes / No)

SIR 2-14B3-S/R02-14B-DPCo.

148013-116542 None None None UNK Corrected NO SIR 2-14B-14802-1413- DPCo. None None None UNK Corrected 148013-1-6543 NO

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1 1731948 6 of 6

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o NUT, HEX, HEAVY HEX, 5/8", 11 UNC-2B, CARBON STL, ASME SA194 GR 2H, ANSI B 18.2.2, ASME SECTION III SUBSECTION NB O ROD, THREADED, 5/8", 11 UNC-2A, ALLOY STL, ASME SA193 GR B7, ASME SECTION III SUBSECTION NB

@ WASHER, HARDENED STEEL, CIRCULAR, 5/8", CARBON STL, ASTM F436 TYPE 1, ASTM F436 o WASHER, HARDENED STEEL, CIRCULAR, 3/4", CARBON STL, ASTM F436 TYPE 1, ASTM F436 O WASHER, HARDENED STEEL, CIRCULAR, 1/2", CARBON STL, ASTM F436 TYPE 1, ASTM F436 O S/R2-14B-1480B-H6542, replaced 1/2" x 3" U-Bolt, 1/4" x " U-Bolt (2), and 3'3" of 3'x3"x3/8" Angle

  • S/R 2-14B-1480B-H6543, added 1/2"x3" U-Bolt, 1/2"x9"x9" Plate, 1-1/2"x24"x3/8" thick flat plate and 3'x3"x3/8"x25-1/2" long Angle iron.,

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization N~umber Not Applicable Expiration Date Not Applicable Signed * . a *- L* .L " Date I Z/4-oS Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of AJobr-,/l ef4,*;ecZ1AJA and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,3 - -o30 to / 7- .05 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions Inspector's Signature National Board, State, Proviuce, and Endorsements Date 17 9'

Form NIS-2 Owner's Report for Repair/Replacement Activity c)

As'required by the provisions of the ASME Code Section XI -w

- - , .nA'erC Q0 .- A Work Order Number Sheet n  :< k.-.. ... 01733889 I of 2

- q - 6.

1. Owner 2. Plant I Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date t,

Charlotte, NC 2820 1-1006 Seneca, SC 29672

/- -2 0

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526Souflt Chiirfi Sfiet .NotAplicabl-Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Reactor Building Spray System, ASME Class 2 5.

(a) Applicable Construction Code: USAS B331.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components . -- -

Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No) 2BS-26 Velan Valve 972018-2 UNK UTC 982180 Unk Installed YES Co.

Piping DPCo. None None None 2007 Installed NO

7. Description of Work OD201490 added a 4" diameter branch connection that included 2BS-26.
8. Test Conducted D Hydrostatic l Pneumatic Nominal Operating Pressure LI Exempt [j Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI /

Work Order Number Sheet S173 I'l 2of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 2- 7- 4(

0 0

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed / fv_- D__

Date .

Owner or Owner's Designee, Title "

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of 41oerwZ " w., and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period "_-/-_

_ _ 7 _ to ,-_-o8' ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

______________Commissions ,,/l/_/___,,_..)/,_'______.--

Inspector's Signature National Board, State, Province, and Endorsements Date / Oc.

I C

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01737591 I of 3

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/16/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Main Steam, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 2MS-155 Crane Co UNK N/A N/A UNK Removed NO 2MS-155 Velan 082017 N/A UTC 1911752 2008 Installed YES
7. Description of Work OD201844/EC95069 replaced valves and piping in'the B-train Main Steam header branch path for the Atmospheric Dump and Vent Valves to resolve leakage problems and to upgrade the valves to QA Condition 1. The upgrade to QA Condition I would permit additional licensing credit to be taken for the use of this flow path, if desired in the future.
8. Test Conducted FD Hydrostatic D Pneumatic ZE Nominal Operating Pressure [D Exempt E] Other Pressure PSI Test Temperature _F

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01737591 2 of 3 1

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/16/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Main Steam, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 4 4 4 + 4 4- I 2MS-156 Velan Valve 082018 N/A UTC 1911753 2008 Installed YES Piping DPCo N/A N/A N/A 2008 Installed NO 4 4 4 + I I-

-a- + + + 4 4

______ _______I ~I ______

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet I .01737591 3 of 3

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

O 2MS-155 (removed) was not manufactured as an ASME Section XI component and therefore has no data to report.

2MS-156 was upgraded from Duke Class G to Duke Class F (ISI Class C), therefore, the valve that was removed Was not included in the ASME Section XI program.

0 0

0 0Q 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed pO)J!*O*wne*r&r(*y lti., e. , Date , -(i* *c wner or ner s Desie gnee, "'"i :

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period -I -o to / - eZ C? , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_______________________Commissions </6,/*'X 4/ A4, pnspg nature National Board, State, Province, and Endorsements Date / "? a 02

'Form NIS-2 Owner's Report for Repair/Replacement Activity As'required by the provisions of the ASME Code Section XI SWork Order rNumber Sheet :

1746001 1 of 2

1. Owner .2. ........ ..... Plant . *- .. Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 - j Seiheca-SC
  • 29672 ...... 11/25/2008 11/25/2008
3. Woikperformed by . ... T.Ie*iCode'S*mb6l Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System,'ASME Class HPI, ASME Class 2 5.

(a) Applicable Construction Code:. ASME Section 111 .19 68 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 2B Letdown Filter Filterite Corp. Unk Unk None 1968 Corrected YES
7. Description of Work Replace eyenuts, eyebolts, and pins on 2B letdown filter. The new eyenuts are SA 194 Gr 8F, the new eyebolts are SA193 Gr. B8, and the new pins are SS 304 (reference OM-201-0128).

"8. Test Conducted FI Hydrostatic E'"Pneumatic Eli Nominal Operating Pressure L] Exempt 0 Other Leak Check Pressure PSI Test Temperature °F

'Foilý NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI .......

Remarks - . .. - Work Order Number Sheet

... .... A7 4 6 0 0 1 2 o f 2:

(pplicable (arks Manufacturer's Data: Reports to be attached)

O Replace eyenuts, eyebolts, and pins on 2B letdown filter. The new eyenuts are SA 194 Gr 8F, the new eyebolts are SA 193 Gr.

-B8, and the new-pins are SS 304-(reference-OM-201-0128), . . . . . .

C OF COMPL-AN- -

§ 0

0 0

0i CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Numb r Not Applicable Expiration Date Not Applicable Signed Senior Engineer Date 11/25/2008 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,, -7q'* , , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period '/- ?, - J to /- ,--'! ,27J , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

__ _ _ _ _ _ _ _ _ _ _ _ _ _ ~Commissions _ _ _ _ _ _ _ _ _

,'Inspector'- Signature National Board, State, Province, and Endorsements Date 7- -'-9*-  ::/

Form NIS-2 Owner's Report for Repair/Replacement Activity C2 As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01752865-01 I of 2 I

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/21/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class High Pressure Injection, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected,- ASME Component Manufacturer Serial Number Board No. Identification Built Removed,. Code or Installed Stamped (Yes / No) t 4 4 4 4 4 4 2HP- 120 Valve CCI 706571-1-1 None None 1998 Corrected. NO

- --- t 7-Description of-Work- -

During the valve PM, Maintenance identified that the valve spindle was damaged from the flow conditions.

_8..._Test.Conducted ............. - ==-in

- '[] Hydrostatic'-- [I] Pneumatic -Nominal Operatin, Pressure l[-i Exempt Other Vtiual ..

Pressure PSI Test Temperature

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01752865-01 I 2 of 2

/

W 9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Valve spindle, S/N 2, UTC # 0001913332, Cat ID 486801, Material - ASME SB637-N07718 0

§ 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed . * /

  • ate ////OI Z Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of , -o,*A and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /-.1 -,12 to -_-c, , and state that to__the best of my. knowledge. and belief, ..the Owner.-has: performed. examinations and taken corrective measures.

.described in this Owner's Report-in accordance with the requirements ot the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the lpct6-rhorei-nplby-e sh-allbe-liable&in--i-any*-manner.-fo-r---an- -personal injury or property damage or a loss, of -any kind arising from or connected with this inspection.

__ _ _ _ _ _..........__ _ _ ..... Commissions , __o_ _ _ _-" __,._,,,_ _..

.. ignature.

'pectors. ........................ .Nationaf Board, State, Province, and Endorsements Date g.1-/ 0' - .. .

Form NIS-2 Owner's Report for Repair/Replacement Activity As required.by-the provisions of the ASME Code Section XL. ""

"*"!:*. - ' * * .... W rk Order Number Sheet O01752872 1 of 2 6 W

-1..: Owner 2.: Plant---------- - - - - . .Unit- - -

Duke Power Company Oconee Nuclear Station ONS- 2

--..-,526 South Church Street 7800 Rochester Hwy Date -.. .

Charlotte, NC 28201-1006 Seneca,. SC 29672 11/24/2008

3. Work Performed by Type Code Symbol Stamp .

Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class LPSW, ASME Class 5.

(a) Applicable Construction Code: USAS B31.1 19 ' 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME

- Codmponent Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

"C" RBCU supply NA NA unk NA unk Corrected NO

& return flanges

7. Description of Wgrk Change/replace 6" CS flanges with SS
8. Test Conducted D Hydrostatic E-l Pneumatic Nominal Operating Pressure Exempt r Other Functional/Visual Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMEECodeSection X. S.....

.Work Ordei Number 2 sheet 01752872 2 of 2

9. 'RemarkO (Applicable Manufacturer's Data Reports to be attached).-

O-0FIL-ANGE, PIPE, WELD NECK, 6", SS, ASME SA182, F304,-RAISEI)j-450ýELBSCH 40, ANSI -B165*-1004U1-MA1DOB060, -

B, ASME SECTION III SUBSECTION NC r..d / *,7-o ..

0 0

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed c__

  • e--",

. C.G. Abellana - Engineer Date 11/24/2008 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ./,r-, ,,o4/.A' and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period i* - e. 7- o* to / -Zo -07" , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions C_.Jc-/*,*"*2/,,,e.--

- Inspector's Signature National Board, State, Province, and Endorsements Date / -2 0 -c*/'

c:ýi?

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Work Order Number Sheet 01754287 I of 3 1

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/16/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Main Steam, ASME Class 2 5.

(a) Applicable Construction Code: USAS 1331 .1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For RIR Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No) 2MS-153 Velan Valve 082013 N/A UTC 1908731 2008 Installed YES
7. Description of Work OD201843/EC95068 replaced valves and piping in the A-train Main Steam header branch path for the Atmospheric Dump and Vent Valves to resolve leakage problems and to upgrade the valves to QA Condition 1. The upgrade to QA Condition I would permit additional licensing credit to be taken for the use of this flow path, if desired in the future.
8. Test Conducted D Hydrostatic [L] Pneumatic [] Nominal Operating Pressure [] Exempt [] Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X[

Work Order Number Sheet

_ 01754287 2 of 3

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/16/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Main Steam, ASME Class 3 5.

(a) Applicable Construction Code: USAS B3 1.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 2MS-154 Velan Valve 082015 N/A UTC 1911750 2008 Installed YES Piping DPCo N/A N/A N/A 2008 Installed NO

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 3-I 01754287 of 3

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o 2MS-153 (removed) was not manufactured as an ASME Section XI component and therefore has no data to report.

@ 2MS-154 was upgraded from Duke Class G to Duke Class F (ISI Class C), therefore, the valve that was removed was not included in the ASME Section Xl program.

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed OtALtb jLtZIA Pv. if-eH:c-I.,iDate 1.-(2.-

Owner or 0%vner's besignee, Tie CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of 4. I 0 -," / and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period - - o to / - 2 o 5? , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Sec tion XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions AiC/'--*'* 7 .JI,4c-DI -nspector- s inature National Board, State, Province. and Endorsements Date _ 0__

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01758537 I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/06/09
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class ASME Class .3 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section X1 Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No) 14B-0-1480A- *'I H3B; D.E.C. NONE NONE NONE 1973 H36B;... Corrected NO 14B-0-1480A- D.E.C NONE NONE NONE 1973 Corrected NO H36A; 1917472 2-14B-0-1480A- D.E.C NONE NONE NONE 1973 Corrected -NO-H29B; .......

-7.- Description- of Work

-Replaced U-bolts 8-. Test Conducted E.. Hydrostatic E- Pneumatic E] Nominal Operating Pressure Exempt [] Other Pressure -.PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet I 01758537 2of 2 U.

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 14B 1480A-H36B3; 4" U-bolt UTC# 1917472

§ 14B-0-1480A-H36A;4" U-bolt UTC# 1917472

§ 2-14B-0-1480A-H29B; 4" U-bolt UTC# 1917472 0

0 Q

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed Engineer Date 1/6/2009 Owneror Owner's Designee. Title

-OO EnIneer

. .. CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province vi'*, of ,4/o/rV/ v ,j and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period / ' to /- ZO-0 5' , and state that to the best of my knowledge and_-belief,Athe-Owner -has. performed examinations -andtaken. corrective measures described in this Owner's Report inaccordance with the requirements-of-the ASME-Code, Section-Xl*.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning -the examinations and -orrective measures-described in -this Owner's-Report-.-o Furthermore,- neither- the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or-a loss of any kind arising from o onnected with this in7pection. .-

S_ - Commission. /*.-: 'V.Q-/Ad,- n r

-ETmhpector's Signature. National-Roard.- State, PRrovince, and Endorsements Date /- Zo -o0 )

Form NIS-2 Owner's Report for Repair/Replacement Activity jA'srequiiiIredlby te p-hvtionisTof-the ASME Code SectlonXI . . -

....... .... . . ... . . ...... . . ' 1 n.

.. . . *..... ...--.. ... . .. .*.. . ..- .... .  ! . .. o U F..

U 1*t.Ow ner- --: - -- = =: -:--.......... - - " 1. 2.. Plant-

- DukePower Company_ Oconee Nuclear Station 526-South-Church-Street-- -... 7800 Rochester Hwy

--Crhalbtte,-NC 28201-1006 - Seneca, SC 29672 U

3.- Work Performed by -Type Code Symbol Stamp - -.......

Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class Low Pressure Injection, ASME Class 2 5.

(a) Applicabile Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section X1 Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)

Valve 2LP-6 WM Powell UNK LINK UNK UNK Removed NO Valve 2LP-6 Weir 2-53825-A UNK UTC 1918970 2008 Installed YES Valve 2LP-7 WM Powell UNK LINK UNK LINK Removed NO Valve 2LP-7 Weir 1-53825-A UNK UTC 1918279 2008 Installed YES (1) Piping DPCo. UNK LINK UNK 2008 Installed NO Support 2-53 B-Spot-531- DPCo. UNK UNK UNK UNK Removed NO Support 2-53 B-43BEOH0 435B3-EMO-H-50 DPCo. UiNK UNK UiNK UiNK Removed NO (2) Support 2-511B-1435B- DPCo. UNK UNK UNK UNK Corrected NO H5572 ,_-

7. Description of WOrk OD201895 replaced valves 2LP-6 and 2LP-7 with valve item # DMV-1448. New piping has been installed and hangers Sffected.
8. Test Conducted

- D Hydrostatic Pneumatic 0 Nominal Operating Pressure [ Exempt [ Other Pressure PSI Test Temperature °F

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X I. ---- --  :.

- -- - - -.... 0.76.9.9-- - [_ _- - -i

-.. Remarks (Applicable Manufacturer's:Data:Repottbatce) _ -- -- **--_--.-*-*---- . .-- . -

0lnsta~le&14" nine 14'h14-" fi s3V-/"ot:1Y-1"heddrdfor-flaneesA'obr 2LPMandl2LP--zzr

-.. Supp-oft 27-5,I-Bl435B:H5572,ýreplaced3I/4":pat5e-0 0

00 I ce~prtif ta -*

t-1 Bhe 55tatem that this....

ents adedinthe"-p ortare:.....................

corc co fom to. re ure

.. e t th,-he :of

i. CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section XL Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed 6J.4,f-dedL William W. Foster Jr., Engineer 11 Date 1/5/2009 Owner or dlwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of e,- and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period o e - to - , ,/

and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or propefty damage or a loss of any kind arising from or connected with this inspection.

Commissions .,,'_,* ,)/,?,,fC....

'"-Inspector'sSignature National Board. State, Province, and Endorsements Date /-/6-r*-c

Form NIS-2 Owner's Report for Repair/Replacement Activity *7 As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1769207 I of 2 I

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy I Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/20/2007
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Unit 2 "A" High Pressure Injection Pump, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 68 Edition, 06/68 Addenda, No Code Case (b) Applicable Edition Section X1 Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

ON2HPIPOOO Ingersoll-Rand UNK UNK UNK UNK Removed NO ON2HPIP0001 Flowserve SN#O5RLCAO3 UNK PN# 10021919 IJNK Installed" NO 14402001

7. Description of Work Removed old 2A HPI Pump and replace it with a new 23 stage HPI Pump. All other parts were replaced or repiared under work scope as necessary. Parts listed in the remarks section located on second page refer to seal piping that was replaced during the scope of work.

-Ii

8. Test Conducted L-" Hydrostatic 1-- Pneumatic 1L: Nominal Operating Pressure E] Exempt 0 Other Flow Testing Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1769207 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o (3) CONNECTOR, TUBE TO PIPE, SWAGELOK, MALE, 5/8" X 1/2", SS, ASME SA479, 316 {CAT ID# 2275, UTC#1074989 & 1088958}

O (1) CROSS, PIPE, PRECISION, 1/2", SS, ASME SA182, F316 {CAT ID# 317515, UTC#1066697};

0(1) ELBOW, PIPE, 1/2", SS, ASME SA182, F304, 90, SW, 3000 LB, ANSI B 16.11 {CAT ID# 80499, UTC#1079371}

o (3 FT) PIPE, 1/2", SS, ASME SA376, TP304, PLAIN ENDS, SEAMLESS, SCH 80, ANSI B36.10 {CAT ID# 149439, UTC#1846687};

O (1) PLUG, PIPE, 1/2", SS, ASME SA182, F316, HEX, THD, ANSI B16.11 {CAT ID# 154029, UTC#1090155};

0 0

0

§ CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authofizatikn Nwmber  ; ot Applicable Expiration Date Not Applicable Signed , Associate Engineer Date 11/20/2007 O)1er or Owner's De gnee, Title

/U CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,foWcrzi 6a7ot4, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 8-____7-7 to //- Zo- o . , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions - )1"C" ssions

'ý nspector's Signature National Board, State, Province, and Endorsements Date /11-2o-02

Form- NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl Y Work Order Numbe Sheet 01777827 - 01 Page 1 of 2 9unit 1.Owner Duke Power Company 2. Plant Oconee Nuclear. Station Unit 2

526 South Church Street 7800 Rochester Hwy Date 12/2/2008 Charlotte, NC 28201-1006 Seneca, SC 29672-0752

3. Work Performed By Type Code Symbol Stamp Not N Applicable Duke Power Company Authorization Number 526 South Church Street i Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of Systems, ASME Class Main Steam , ASME Class 2 5.

(a) Applicable Construction Cod USAS B31.1 1967: Edition. No Addenda No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 1998: Edition, 2000 Addenda (c) Applicable Section Xi Codes Cases(s) None

6. Identification of Coimponents Name of Component Manufacturer: Manufacturer National Other Year Corrected, ASME Code Serial Number Board No identification Built Removed or Stamped Installed (Yes/No)

(1) 2-01A-1401B-H4284, Hydraulic Lisega 97614263/23 UNK N/A UNK Removed No Snubber 2-01A-1401B-H4284, Hydraulic Anvil 37008 UNK UT C UNK Installed No Snubber 1913770

7. Description'of Work Replace existing Lisega snubber with Anvil 3306
8. Test Conducted F] Hydrostatic E] Pnuematic L] Nominal Operating Pressure El Excempt W Other Visual Pressure PSI Test Temperature Deg. F

Form 'NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl Work Order Numbe - Sheet 01777827 - 01 Page2of2

7. Remarks (Applicable Manufactuerr's Data Reports to be attached)

(1) Snubber replaced to seal degradation CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl Type Code Symbol Stamp Not Applicable Certificate of Autherization Number Not Applicable Expiration Date Not Applicable Signed _ _ _ _ _ _ _ _ _ _ _ Date /

Owner or Oiner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of AJOe-rW 4!5oe,*_.,e 4' and employed by HSB CT of Hartford. Connecticut have inspected the components described in the Owner's Report during the period "/-z*2 -06 to /1-1. - 07' , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owners Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.

___________________Commision(s) / 4J , ,,,

Inspector's Signature National Board, State. Province. and Endorsements Date /-/,/- r

"Forrn NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl Work Order Numbe Sheet 01788458 - 03 rage I ut £

1. Owner Duke Power Company 2. Plant Oconee Nuclear Station Unit 526 South Church Street 7800 Rochester Hwy Seneca, SC 29672-0752 Charlotte, NC 28201-1006
3. Work Performed By Type Code Symbol Stamp Not Applicable N

Duke Power Company Authorization Number 526 South Church Street i Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of Systems, ASME Class Main Feedwater , ASME Class S.

(a) Applicable Construction Cod USAS B31.1 1967: Edition, No Addenda No Code Case (b) Applicable Edition Section XI utilized For RIR Activity 1998: Edition, 2000 Addenda (c) Applicable Section Xl Codes Cases(s) None

6. Identification of Coimponents Name of Component Manufacturer: Manufacturer National Other Year Corrected, ASME Code Serial Number Board No identification Built Removed or Stamped Installed (Yes/No)

(1) 2-03-0-1401A-H4087, Pivot Pin Anvil N/A UNK UTC UNK Installed No 1019297 2-03-0-1401A-H4087, Pivot Pin N/A N/A UNK N/A UNK Removed No

7. Description of Work Replace worn load pin
8. Test Conducted LI Hydrostatic F] Pnuematic E] Nominal Operating Pressure LI Excempt [ Other Visual Pressure PSI Test Temperature Deg. F

(

ýForm NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl Work Order Numbe Sheet 01788456 -03 Page 2of 2

7. Remarks (Applicable Manufactuerres Data Reports to be attached)

(1) Replaced worn load pin CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp Not Applicable Certificate of Autherization Number Not Applicable Expiration Date Not Applicable Signed . i. t. Date' _ _,_-Or3 Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of .,4Jo,,eFr' C,,eL..,wQ and employed by HSB CT of Hartford, Connecticut have inspected the components described in the Owner's Report during the period O - ;* " to Iow

-- -, 7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.

on(ommision(s) _/

Inspector's Signature National Board, State. Province, and Endorsements Date /-le'-o f

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI F-Work Order Number I Sheet 1797984 1 of 2

'1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station - ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/25/2008

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class HPI, ASME Class 2 5.

(a) Applicable Construction Code: ASME Section II 19 68 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected; ASME Component Manufacturer Serial Number Board NO. Identification Built Removed, Code or Installed -Stamped (Yes / No) 2A Letdown Filter Filterite Corp. Unk Unk None 1968 Corrected YES r- -Co -------.

7.. Description of Work Replace eyenuts,,eyebolts, and pins on 2A letdown filter. The new eyenuts are SA 194 Gr 8F, the new eyebolts -are.-.-.-

SA193 Gr;B8, andtihe new pins-are SS 304 (reference OM-201-0128).

8. Test Conducted

[!- Hydrostatic I] Pneumatic E] Nominal Operating Pressure' r- Exempt Other Leak Check*

Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1 '7/C7QA "), , )

14 9F9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Replace eyenuts, eyebolts, and pins on 2A letdown filter. The new eyenuts are SA 194 Gr 8F, the new eyeblilts are SA193 Gr.

B8, and the new pins are SS 304 (reference OM-201-0128).

0 o

0 0

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and thatthis conforms to the requirements of the ASME Code, Section X1.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed W _ Senior Engineer Date 11/25/2008 Owner or Owner's Designee, Title I. 'U CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period -/. o g' to "I_-,/ 7o,,' , and state that to the best of my knowledge and belieft ormed en corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing th is -certificate neither. the. Inspector. nor. his. employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind~arisingfrom or connected with-this inspection,.

Commissions .,) C1/A 1/-,,C_

Inspector's Signature .National Board, State, Province, and Endorsements Date /Y-0 7

  • 7 Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI p

.. ° Work Order Number Sheet

.... I - 01798519 lof 2

-1. -O w n e r - .. - - - . . . . . . P la n t ...

-.... Un it .......

Duke Power Company Oconee Nuclear Station ONS - 2

-.56 South Chu~rchStreet - -7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/22/2008

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Feedwater, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)
  • 2-63-1439A-115443; D.E.C. NONE NONE NONE 1973 Corrected H5443; Hanger NO
7. Description of Work Replace 6" U-bolt
8. Test Conducted LI Hydrostatic L] Pneumatic L-1 Nominal Operating Pressure Exempt Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity

__As required by the provisions of the ASME Code Section XI I

Work Ordeer Number Sheet 17985.19 2 of 2

-9.- Remarks (Applicable-Manufacturer'sData-Reports-tobe attached) -... ..--

=OW6LUIbof UTC#OOOI8316LPN#137N.. . . .... .

0 0

0 e

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed ýa"ojy, tap/ Engineer Date 12/22/2008

- Owner or Owner's'Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of 4 ,ew ,, , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period to , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

h ** .Commissions At / //A,1 fC-

Ž Inspector's Signature National Board, State, Province, and Endorsements Date / o-f//

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01831432 I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/22/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 2 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 2-14B-1480C- D.E.C. NONE NONE NONE 1973 Corrected NO

.H6540

7. Description of Work Reinstalled hanger/support
8. Test Conducted

[]Hydrostatic 1-- Pneumatic ["] Nominal Operating Pressure Exempt []Other *-

Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01831432 2 of 2 1

-U

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o 3" U-bolt UTC#0001077381 PN#137N, 1" U-bolt UTC#0001907896 PN#137N, 2" Flat bar UTC#0001898853 Trace: M HT#770516 0

0 0

0 0

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed 0 ,ý zv/ ze/', Engineer Date 12/22/2008 11-"/Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid co rpission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,I-r,, ,,,. . and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /1-Z '- -*f to /-/S-fY * , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions AI*_/*'/' &,

Inspector's Signature National Board, State, Province, and Endorsements Date ""-- 2"

Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section XI Work Order Numbe Sheet 01831432 - 54 Page 1 of 2

- ~ runit WI 1. Owner Duke Power Company 2. Plant Oconee Nuclear Station Unit 2

526 South Church Street 7800 Rochester Hwy Date 12/8/2008 Charlotte, NC 28201-1006 Seneca, SC 29672-0752

3. Work Performed By rype Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of Systems, ASME Class Low Pressure Service Water ASME Class 2 5.

(a) Applicable Construction Cod USAS B31.7 1969 Edition, No Addenda No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 1998: Edition, 2000 Addenda (c) Applicable Section XI Codes Cases(s) None

6. Identification of Coiirponents Name of Component Manufacturer: Manufacturer National Other Year Corrected, ASME Code Serial Number Board No identification Built Removed or Stamped Installed (Yes/No)

Two (2) 12" Sections of 3" CS piping N/A na UNK.. na UNK Corrected No

7. Description of Work Piping required temporary removal to replace 2B1 Motor Upper Air Cooler
8. Test Conducted LI Hydrostatic E] Pnuematic LI Nominal Operating Pressure L] Excempt [ Other Funtional Pressure PSI Test Temperature Deg. F

Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xi Work Order Numbe 01831432- 54 Page 2 of 2 I Sheet 7 7. Remarks (Applicable Manufactuerr's Data Reports to be attached) I CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI Type Code Symbol Stamp Not Applicable Certificate of Autherization Number Not Applicable Expiration Date Not Applicable Signed Geary L. Armentrout, Principal Engineer 1 _4" Date 12/8/2008 Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of A,'oe r/,, Ct,*,,.,., and employed by HSB CT of Hartford, Connecticut have inspected the components described in the Owner's Report during the period / -, o#0 to / - - oY ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.

Commision(s) A/C Inspector's Signature National Board, State, Province, and Endorsements Date //,zz/ f '

Form NIS-2 Owner's Report for Repair/Replacement Activities

' srecqifIred bi the Ii -

f provTsiohns' ofth-e ASMECoII de Section Xl Work t)rder Numbe

-01844529.- 01 Sheet:

Page I of 2

1. Owner D---o--e, .2. -ompaty; Plant -Oconee-Nuclear Station Unit U

2 526 South Church Street 7800 Rochester Hwy

. . . ........ .. Date 12/4/2008 Charlotte, NC 28201-1006 Seneca, SC 29672-0752

  • 3. W ork Performed -By TypeCode Symbol Stamp NotApplicable Not Appliale Duke PowerCompany- .... ........

Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of Syetn~m A5MUFCrI1...

Main Steam , ASME Class 2 5.

(a) Applicable Construction Cod USAS B31.1 1967: Edition, No Addenda No Code Case (b) Applicable Edition Section Xi Utilized For RJR Activity 1998: Edition, 2000 Addenda (c) Applicable Section XI Codes Cases(s) None

6. Identification of Coimponents Name of Component Manufacturer: Manufacturer National Other Year Corrected, ASME Code Serial Number Board No identification Built Removed or Stamped Installed (Yes/No)

(1) 2-01A-0-1481A-H8A, Hydrauilc Grinnell 35553 UNK N/A UNK Removed No snubber 2-01A-0-1481A-H8A, Hydrauilc Anvil 36534 UNK UTC UNK Installed No snubber 1919361

7. Oescription of Work Replaced leaking Grinnell Fig. 200 snubber with Anvil Fig. 200.
8. Test Conducted F] Hydrostatic F] Pnuematic D] Nominal Operating Pressure D Excempt [] Other Visual Pressure PSI Test Temperature Deg. F

- Form NIS-2 Owner's Report for Repair/Replacement Activities

.As required. by the provisiohs of the ASME Code Section XI Work Order Numbe Sheet P 01844529 - 01 Page 2 of 2 1

,,1 -; I%

-7. RenirIwi(Applt~bTe ManQT- t~es D-ataRepodrtS toe attached)

(I) Replaced leaking Grinnell Fig.: 200 snubber withAnvil Fig. 200.

CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl Type Code Symbol Stamp Not Applicable Certificate .of Autherization Number Not Applicable Expiration Date Not Applicable Signed / 6 -er, Date _____.____

Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of A e./o*,-,,, /,,o.*, and employed by HSB CT of Hartford, Connecticut have inspected the components described in the Owners Report during the period /12.-.. - Oc to /- If- of , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.

~ Commision(s)

Ins e Signature National Board, State, Province, and Endorsements Date /-__ __ __ __

Form NIS-2 Owner's Report for Repair/Replacement Activity Clý As required by the provisions of the ASME Code Section XI Work Order Number Sheet 098729486 (1657123) I of 2

i. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/10/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class CCW, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No) i) Pratt NA NA NA NA Corrected YES (2) Pratt NA NA NA NA Corrected YES t I 4 4 + -t I 4 1 4 4 4 4 4 4 + 4 4 4 4 4-
7. Description of Work Replacement of the two (2) 96" Rubber Expansion Joints at the Intake Structure. Note: the other expansion joints were replaced the previous Unit 2 Fall outage.

V, -

Test Conducted

[--]1-ydrostatic 1 Pneumatic L--Nominal Operating Pressure [] Exempt [Z] Other Functional Pressure PSI Test Temperature

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Work Order Number Sheet 098729486 (1657123) 2 of 2 W. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 2"A" Unit 2 CCW Pump Discharge 96" Rubber Expansion Joint 0 2"B" Unit 2 CCW Pump Discharge 96" Rubber Expansion Joint 0

0 C O C 0

0 0

0 qD CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization N ber Not Applicable Expiration Date Not Applicable Signed.,1 "* 7 *_, Geary L. Armentrout, Principal Engineer Date November 10, 2008 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of llo, -,o and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 10-e/- o06 to /- " 0,,o7 1 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions ,A/C6/,i'/ A',,,

I I nspector's Signature National Board, State, Province, and Endorsements Date V_ 0 f___ _

Fohri'NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisiqns of the ASME Code Section XI Work Order Number Sheet 1674321 lof 2

1. Owner .. 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 3 526 South Church Street 7800 Rochester Hwy Date CharIotte-e, NC 28201-1006 Seneca, SC 29672 10/9/2008

-3_ Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class Condenser Circulating Water System, ASME Class 3 5.

(a) Applicable Construction Code: USAS B3 1.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XAUtilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 03CCW PU 0002 Sulzer 550-50321-2 UNK None UNK Corrected NO
7. Description of Work The 3B CCW pump packing gland was removed so that the packing gland studs could be replaced. The original bronze studs have been failing in service. New stainless steel studs have been recommended by the vendor. One stud on the 3B hump has failed, but all are being replaced as a preventative measure.
8. Test Conducted LI Hydrostatic LI Pneumatic 0 Nominal Operating Pressure D Exempt E] Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1 1674321 2of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 -Installed 2 new packing gland studs - ASTM A 193 B8 - Heat Number 151723

- Installed 2 new-packing gland nuts - ASME SA194 Grade 8M - Heat Number 550519 0

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate ou ization m J No, Applicable , Expiration Date Not Applicable Signed 0, Engineer Date 10/9/2008 L Owneor Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of o and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period - Co o 6s- to 0/-7 o , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

P__________________Commissions .(/.-C -

nspector's Signature National Board, State, Province, and Endorsements Date /-

Forim NIS-2 Owner's Report for Repair/Replacement Activity C

As required by the provisions of the ASME Code Section Xl Work Order Number Sheet 01714790 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ] ONS - 0 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/4/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class SSF Diesel Jacket Water, ASME Class 3 5.

(a) Applicable Construction Code: ASME Section III 19 74 Edition, 1975 Addenda, Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s)

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, - Code or Installed- Stamped (Yes I No)

DJW PU 00B1 EMD unknown unknown UTC#1057432  ? Removed NO DJW PU 00B1 EMD unknown unknown UTC#1893896  ? Installed NO

7. Description of Work SSF DJW PU 0OBI REPLACE LEAKING WATER PUMP B ENG. 12 CYL.
8. Test--Conducted - *

['I Hydrostatic [- Pneumatic VI NominalOperatingP-essure [j Exempt Other Normal Dies@ run.

Pressure 20 PSI Test Temperature 168 OF ..

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I

Work Order Number Sheet 01714790 2 of 2 I

9. Remarks (Applicable Manufacturer's Data Reports to be attached)

O N/A 0

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed /* / 14, r,/

'-. Date //,l P Owner or Owner's Designee, Title U CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of - , and employed by of ,_have inspected the components described in this Owner's Report during the period . c.,

U,&/ to / , , , and state that

.to the best- of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing..this certificate neither the Inspector nor his employer makes any warranty, .expressed. or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from*r connected with this inspection.

/[_______._________ Commissions ,J /z,- 'A ,d _ *

'Inspector's Signature National Board, State, Province, and Endorsements Date ____ -C>7 __

Form NIS-2 Owner's Report for Repair/Replacement Activity, As required.by the provisions.of the ASME Code Section-XI Work Order Number Sheet I*17L 13960-05 1 of 2 1:. Owner:. . .. 2. Plant Unit Duke-Power Company Oconee Nuclear Station ONS - 0 526 South Church Street . - 7800 Rochester Hwy Date

. Charlotte, -NC 28201-1006-. Seneca, SC 29672 10/6/2008

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Spent Fuel Demineralizer, ASME Class 3 5.

(a) Applicable Construction Code: ASME Section III 19 65 Edition, No Addenda, Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 Edition, Addenda.

(c) Applicable Section XI Code Case(s) - -

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Manway Bolting UNK N/A N/A N/A UNK Removed NO Manway Bolting UNK N/A N/A N/A 2008 Installed NO

7. Description of Work Replaced Manway Bolting on the Spent Fuel Demineralizer
8. Test Conducted

.I- Hydrostatic l: Pneumatic E Nominal Operating Pressure I: Exempt Eil Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I

Work Order Number Sheet 1743960-05 - 2 of 2

-9. Remarks (Applicable Manufacturer's Data Reports to be attached) o 40 x 1 1/8" Nuts: SA 194 GR 7 - UTC# 1907651 C OF COMPLIANCE 0

0 r CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed 6i-,...~... Aaron Best, Engineer Date 10/06/2008 Owner or Owner's signee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of f ,, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 57- ,. "c-5 to /-,/f- o 7 , and state that to the, best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions 2/'*AJX,*'J- ci/C_

inspector'DsSignature National Board, State, Province, and Endorsements Date _ _ _ _ _ _ _

Form NIS-2 Owner's Report for Repair/Replacement Activity C1 As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01752474 I of 2 UD p -

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/18/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class High Pressure Injection System, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Correctedý, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 2-5 IA-0-1479A-H19C; 2 1/2"; U D.E.C. NONE NONE NONE 1973 Installed NO bolt
7. Description of Work Replaced U-bolt
80. Test Conducted

- Hydrostatic []Pneumatic []Nominal Operatiiig Pressure Exempr E]o ther Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1 01752474 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o 2-5 IA-0-1479A-H19C; 2 1/2" U bolt - UTC # 0001916330 PN# 137N 0

0 0

0 0

0 0

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed 2&cJ,,- ,--

  • Civil Engineer Date 12/18/2008 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of j,,ex,* and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period _-___-__ to /-/'407 , and state that

-tO6the6 'b6st9 of'my knowlddge and. belief; the Owner has -peformed examinations and taken corrective Tneasures described in this Owner'sReport-in accordancewith the requirements of the ASME Code, Section Xh.-

--,----By signing- this -certificate -neither the Inspector nor his employer makes any warranty, expressed or- implied,

-concerning ..the. examinations -and corrective measures described in this Owner's Report. Furthermore, neither-the Inspectorinor ihisemployer shall-be liable in any manner for any personal injury or property damage or a Io'ss of any kind arising-from-or connected with this inspection.

O_______________ ........... Commissions .

  • ý.-pector's Signature - - . ..... - - National Board, State, Province, and Endorsements Date /-/* c  %

Forjm NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01763290 I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station " ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006. Seneca, SC 29672 4/07/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Essential Siphon Vacuum System, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 2ESV PU 0002 Siemens UNK 1998 Removed NO 0 ESV PU 0001 Siemens UJNK 1996 Installed NO
7. Description of Work The existing pump was removed to be rebuilt and replaced with an in house spare pump. Once rebuilt, the pump just removed will become the spare for the next pump to be rebuilt.

U.-

M. Test Conducted L--- Hydrostatic L Pneumatic n Nominal Operating Pressure -- Exempt [ZOther Pressure PSI Test Temperature OF

,Forjn NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I I Work Order Number Sheet 01763290 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0

0 0

0 0

0 o

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section X1.

Type Code Symbol Stamp Not Applicable Certificate of Auth i tion ber Not Applicable Expiration Date Not Applicable Signed Engineer Date 4/7/2008

.X-*' Owner (r, Ov4Wer's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A,/oer' 6.otz,_ and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period V o0 to " -- f.-v.og , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a Icss of any kind arising from or connected with this inspection.

__________________________ Commissions JLCYYVVA)/44, Inspector's Signature National Board, State, Province, and Endorsements Date "

-2 -o_-_ 6

Form NIS-2 Owner's Report for Repair/Replacement Activity 0__

As required by the provisions of the ASME Code Section XI U

1Al1 r% ." KI "

Sheet

- 'I -

I 1765215 Unit 1 of 2 II. Owner 2. Plant Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 10/27/2008 3, Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class Feedwater System, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, - ASME Component Manufacturer Serial Number Board No. Identification Built Removed, - Code or Installed Stamped (Yes t No) 4X8X10.5B 2FDW PU 0003 Sulzer 280066 LUNK 1969 Corrected NO MSD

-~ -- -- --

7. Description of Work The Unit 2 Turbine Driven Emergency FDW pump packing glands were removed so that the packing gland stds-could be replaced. The original studs have limited thread engagement and new studs are available from the vendor that provide more engagement. The replacement of these studs is a preventative measure only.
8. Test Conducted El] Hydrostatic Pneumatic Nominal Operafing Pressure r]Exempt Other .

Pressure __ PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 1765215 I 2 of 2 0 Installed 4 new packing gland bolts 1( 7"3,4 2'rug , z

/7._.

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

-Type Code Symbol Stamp Not Applicable Certificate of Author* ationNumber Not Applicable Expiration Date Not Applicable Signed Engineer Date 10/27/2008 V Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A~rv.ceA4 and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /0 -Z7"- of to /_- - 0?, and state that

-to 'the -besrt-of'my -knowledger and -belidf,"the -Owne'r has dnh1armd examinations and taken corrective, measures

-describyed in-this Owner's-Report in-accordance with the requirements-of the ASME Code, Section Al - -

-By signing -this- certificate- neither the Inspector nor his employer makes any warranty, expressed or- implied,.

-,concerning-.the examinations and corrective measures described in this Owner's Report. Furthermore, neither_ t-he Insector nd hist employer shall be liable in any manner for any personal injury or property damage or a ross of any-kind arising from or connected with this inspection.

-Inspectors SignatureCommissions -AI /* x? C .......

S -Inspector's Signature "- - "National Board, State, Province,-and Endorsements Date /.r - ,i~ "-*--

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Work Order Number Sheet 1767211,1796511,1767212 I of 8 k

-1 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/7/2009

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 12LPSW- 1109 Fisher Controls 16986196 7479 UTC 1821686 2006 Installed YES 2LPSW- I111 Crane Nuclear D4711 36 UTC 1092866 2006 Installed YES 2LPSW-1 113 Fisher Controls 16986201 7500 UTC 1822986- 2006 Installed .YES 2LPSW- 1114 Fisher Controls 16986197 7478 UTC 1831112 2006 Installed YES 2LPSW-1 116 Crane Nuclear D4714 38 UTC 1093184 2006 Installed YES 2LPSW- 1118 Fisher Controls 16986198 7477 UTC 1831113 2006 Installed YES 2LPSW-I 119 Fisher Controls 16986207 7472 UTC 1820745 2006 Installed YES 2LPSW-1 120 Fisher Controls 16986216 7498 UTC 1823876 2006 Installed YES 2LPSW-1 121 Fisher Controls 16986229 7520 UTC 1921110 2007 -Installed . YES_.

7 . - 4.:

.' ... ~ t,' z s r IL.

7. Description of Work Items being installed in accordance with NSM ON-23117. There are numerousvalve additions in the LPSW Supply Headerstd-the Reactor1B3iilding-and in-the common headers from theReactor-Building. Also the common return header Lis being dividedinto two-paralleea-l tie- hr--iiiih-asetbof air-operated -vaives.

- U-F8. Test Conducted -.. -- -.. ..

D- Hyrostatic

-Peumati-e Nominal Operating Pressure"" Exempt D Other Pressure ..... ..... PSI ..... . - Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1767211,1796511,1767212 2 of 8

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/7/2009
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 3 5.

(a) Applicable Construction Code: USAS B3 1.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section X1 Utilized For R/R Activity 19 98 Edition, 2000 Addenda..

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASMVE Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 2LPSW-1 122 Fisher Controls 16986222 7493 UTC 1921081 2006 Installed YES 2LPSW-1 123 Fisher Controls 16986230 7521 UTC 1921111 2007 Installed YES 2LPSW-1 124 Fisher Controls 16986228 7518 UTC 1921109 2007 Installed,- YES 2LPSW-1 125 Fisher Controls 16986215 7482 UIC 1824449 2006 Installed YES 2LPSW-1 126 Fisher Controls 16986209 7506 UTC 1822987 2006 Installed YES 2LPSW-1 134 BNL Industries A060309-2-1. 'INK UTC 1092709 2006 Installed YES 2LPSW-A 135 Anderson Greenwood N99989-00-0001 UNK UTC 1895299 2007 Installed YES 2LPSW-1 137 BNL Industries A060414-1-1 UNK UTC 1093090 2006 Installed YES 2LPSW-1 148 Flowserve BD360 1916 UTC_1894923 2007--- -- Installed -----YES----

2LPSW-1 149 Flowserve BD361 1917 UTC 1909563 2007 Installed YES 2LPSW-1 150 Velan Valve *082038 .. .N/A - I .U-TC-l9J-902 7-:ý-'2008 -.Installed YES

- I 2LPSW-1 151 Velan Valve 082037 N/A UTC19119820 -2008 Installed YES

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 17672 11,17965 11,1767212 3 of 8

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/7/2009
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.1 19 67 Edition', No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section X1 Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 2LPSW-1 152 BNL Industries A060415-2-2 UNK UTC 1823861 2006 Installed YES 2LPSW-1 172 BNL Industries A080121-28-4 UNK UTC 1912055 2008 Installed YES 2HPSW-943 Flowserve 08BEJ 1631 UTC 1092218. 2006 Installed YES 2HPSW-950 BNL Industries A080121-28-1 UNK U.UTC 1910332. 2008 Installed YES 2HPSW-951 BNL Industries A080121-28-2 UNK "UTC '1912053 2008 Installed YES 21 A-2964 Flowserve E371A-37-2 2217 UTC 1014704 1999 Installed YES 21A-2967 BNL Industries A080121-28-3 UNK UTC 1912054 2008 Installed YES 2LPSIV0547 BNL Industries A050808-8-53 UNK UTC 1822251 2006 Installed YES 2LPSIV0548 BNL Industries A050808-8-58 UNK UTC 1822773 2006 Installed YES 2LPSIV0549 BNL Industries A050808-8-60 UNK UTC 1822775 2006 Installed YES 2LPSIV0549 - - L-BNL-Industries - A050808-8-59 -UNK UTC 1822774: 2006 Installed.- YES 2LPSIV0557--: BNL Industries A05080848-54 UNK UTC 1822769ý - 2006 Installed YES-

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1767211,1796511,1767212 4 of 8 Fl U.

w'l 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/7/2009

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006' Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 3
5. "

(a) Applicable Construction Code: USAS B331.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 12LPSIV0558 BNL Industries A050808-8-44 UNK UTC 1090888 2006 Installed YES 2LPSMJOO II Flexonics K22660-1-1 N/A UTC 1093252 2006 Installed YES 2LPSMJOO!2 Flexonics K22550-1-2,.... N/A_. UTC 1912299 2006 Installed YES YES (1) Piping DPCo None None None 2008 Installed NO S/R 2-1413- DPCo None None None 1402A-H4361 2008 Installed NO S/R 2-14B-SDPCo None None None 2008 Installed NO S/R 2-14B-DPCo None None None 2008 Installed NO 1402A-H4364_

S/R 2-14B-DPCo None None None 2008 Installed NO 1402A-H4365 4 I-402A-H4366-- DPCo - None- None- None 2008 Installed NO H 367

ý1402 -- -- - "--- _______

1i02A_.31.g-.)-.-.DPCo---- NoneNNone No *2009 Noe Non

. 2008 Installed NO

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl Work Order Number Sheet 1767211,1796511,1767212 5 of 8 V 9

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/7/2009
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 3 5.

(a) Applicable Construction Code: USAS B3 1.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)

S/R 2-14B-1402A-H4368 DPCo None None None 2008 Installed NO S/R 2-14B-1402-143- DPCo None None None 2008 1402A-H4369 Installed NO S/R 2-14B- DPCo None None None . .. 2008 Installed NO 1402A-H4370 NNed l402-143- DPCo None None None 2008 Installed NO S/R 2-14B-1402A-H4371 142-143- DPCo None None 1402A-H4373 None 2008 Installed NO S/R 2-14B-1429- DPCo None None 1429H-H4374 None 2008 Installed NO S/R 2 1429H-H4375 DPCo None None None 2008 Installed NO SIR 2 1429- DPCo None None None 2008 1429H-H4376 Installed NO SIR 2 SIR 2919- DPCo None None None 2008 Installed NO 1429H-H4377 _ .

S/R 2 DPCo None *None None 2008 Installed NO 1429H-H4378

-SIR 2 . .... . .. . ... ... ... .. . .. ... .... .. . ....... . .... .. ......

D PC o .N . - o n e"_.

. . N fi - .. :.;.' ,'_: N. o.n e .. . .
.--
--- 10 0 8 r-in St a ll e d - O 142H-43'IDPCo .: ..  :*:None-,. ..-': None ... . None -'-2008 installed . -No. -

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1767211,1796511,1767212 6 of 8 6

- 4

'M[1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/7/2009

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code orr Installed I(Yes Stamped I No)
  • S/R 2 1429H-H2-19 DPCo None None None 2008 Installed NO 1429H-H4382 S/R 2 DPCo None - None None 2008 Installed NO 1429H-H4383 DPCo None None None 2008 Installed NO 1429H-H4384 SR21429-H48 S/R 2-14A- DPCo None None None 2008 Installed NO

.S1439A-H5582, SR2143A-H83 S/R 2-14A- D o None None None 2008, Installed NO 1439A-H5583 DPCo None None None 2008 1439A-H5584 Installed NO S/R 2-14A- DPCo None None None 2008 Installed NO 1439A-1-15585 S/R 2-14A-14A- DPCo None None None 2008 31.439A-H5586 Installed NO

  • . .. : . .. ..r.  :,.

-Nn ... .. 2- -08.. - -In ta le .. ..

. ..... - O- *...

_S/R 2-!.4B - . P o . . ... ... .N ne-**- --

1"439A-H5580 DPo...e...-~i&-fNn.-~2 Or~~nsald N S/R 2-14A-DPCo None .. .... Nones__ _....:.<..None ...... .2008 .......-nstaled--i-;.--I--NO--

1439A-H5628 .- ---- ' -- -.. ----

(2)S/R 2-14B1 - e-e-- -..2 0 0 8 1. - C o rre cted NO D PC o -!No n e Non eon -.

4 0 -

A - J B_-1 1901H (3) S/R 2-1 4B- DPCo None None. --..

None ------ _2008 .__ . Corrected- NO -....

I-0-1444-H3 _

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Y

Work Order Number - Sheet 1767211,1796511,1767212 7 of 8

.5

'4W' 1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/7/2009

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 2820 1-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 3 5.

(a)Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

(4) S/R 2-14B-1400A:JEJ- DPCo None None None 2008 Corrected NO 2001

. *E . . ZL -'. " " ,. - . .. "" ". .. .""

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number - Sheet 1767211,1796511,1767212 8 of 8

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 Installed piping; (20) 18", (12) 14", (2) 10", (4) 6", (2) 3", (1) 2 1/2", (2) 2", (1) 1 1/2" flanges; (192) 1 1/8", (96) 1", (12) 7/8",

(16) 3/4", (16) 5/8", (50") studs; (384) 1 1/8", (192) 1", (24) 7/8", (32) 3/4", (40) 5/8", (24) 1/2" nuts.

O S/R 2-14B-0-1401A-JB-1901; Installed (2) 4" x 4" x 1/4" x 2 1/2" 1g. tube steel, (2) 1/2" x 5" x 5" steel plates and (4) WT cut from a W 10x 45 x 4'lg.

O S/R 2-14B-1-0-1444-H3; Removed (1) H.S. (Hanger Standard) 40 riser clamp, installed (1) 14", Fig. 40N heavy riser clamp.

O S/R 2-14B-1400A-JEJ-2001; Change V"x 18", Fig. 137S U-Bolt to tight fit.

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed . ., /- / Date __-Z_-_ _ _ _ _ _

Owner or Oner's Designfee, Title . . -

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of /lJe-r,1 6A*°e,,uf and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z-7. 7o to /- _. C; ýp - , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

_By signi~ngthis__certificate neither the !nspector nor his employer makes any warranty, expressed or implied, 6T6hefiin-tg-_tlh*] 6,*<*ffifrati n-ýa-zn-d,ýc6re-,tiV-e asr6-sd*ib-ed inffthis- Owner's Report. Furthermore, neither the:

Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.*


.--- :rCommissions /'49 &fC-

--:o's Sign~a~ture:------- _-------.---::-*:- - --- -National Board, State, Province, and Endorsement _

Date /e z.-oY .. .. .. .

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Y

Work Order Number Sheet 1767212 I of 2 1

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/7/2009
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped

.. (Yes / No) 2LPSW-I Ill Crane Nuclear D4711 36 UTC 1092886 2006 Removed - YES 2LPSW-1 111 Crane Nuclear D4710 35 UTC 1092865 2006. Installed YES

/ ______ __ _

7. Description of Work Items beinng installed in acco'rdance withNSMON_-23-1JT.There-are-numerous valve additions in-the LPSW Supply-Headers to the ReactorBuilding and in the common headers from the Reactor Building. Also the common-retum header-is being divided int two pparaillefleaders- e.cdltditia*ifýaaset of air 6operf-*edvalves. . - .. .

-U

8. Test Conducted D Hydrostatic Li Pneumatic Nominal Operating Pressure ,-- Exempt Other

-- Pressure ........ PSI ---- Test Temperature

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl ml.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signedq---ý />e/Ak/_j hll,(ate, w

- -- i Owner or-wner's Desilfnee, Title CERTIFICATE OF INSERVICE INSPECTION 1, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of Ao/,C71- 6 and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z o? to _ -__- ___,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

ysigning this -certificate neither the Inspector- nor -his -employer makes-any-warranty, expressed--or__implied,._

concerning the examinations and corrective measures describ&ejdInth"n- r Re isL F'. irl is,-' ff,-r iffil Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any

.kind~arising from or connected with this inspection.

_4;4 _C ornm is & s i ..............

... .i.n. pector's Signature - - National Board, State;,Province,-and. Endorsements- .- -

'-',o,- /.7.Yo r Q S---- 6

C Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1769991,1777844, 1 of 9 17RTQA1

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/10/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Condensate & Emergency Feedwater, ASME Class 3 5.

(a) Applicable Construction Code: USAS B3 1.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Valve 2C-152 UNK UNK UNK None UNK Removed NO Valve 2C-153 UNK UNK UNK None UNK Removed NO Valve 2C-898 Flowserve E602T-1-6 2921 UTC 1053606 2002 Installed YES Valve 2C-899 Flowserve AU322 1134 UTC 1057563 2003 Installed YES Valve 2C-902 Enertech 11282 None UTC 1064524 2003 Installed YES Valve 2C-903 Crane D1062 26 UTC 1056496 2003 Installed YES Valve 2C-904 Crane D1067 30 UTC 1056500 2003 Installed YES Valve 2C-906 Crane D 1116 21 UTC 1054679 2003 Installed YES Valve 2C-907 Crane D1121 25 UTC 1063822 2003 Installed YES

7. Description of Work NSM ON-23098 Part AMI installed &Ior modified piping & valves to provide automatic isolation and single failure protection to the Upper Surge Tank (UST), the safety grade source of water to the Emergency Feedwater (EFW) Pumps, to ensure that non-safety pathways are isolated. In addition, the EFW pump recirculation pathway supports and piping welds were upgraded to seismic design to ensure the UST inventory is seismically protected.
8. Test Conducted r- Hydrostatic I- Pneumatic L2 Nominal Operating Pressure EL Exempt 0 Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI I

Work Order Number Sheet 1769991,1777844, 2 of 9 17R7941

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/10/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Condensate & Emergency Feedwater, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Valve 2C-908 Flowserve E602T- 1-5 2920 UTC 1053605 2002 Installed YES Valve 2C-912 Enertech 11281 None UTC 1064523 2003 Installed YES Valve 2FDW- UNK UNK UNK UNK UNK Removed NO 92 Valve 2FDW- Velan 032063 N/A UTC 1064933 2003 Installed YES 92 (1) Piping DPCo None None None 2008 Installed NO S/R 2-07A--

1207A- DPCo. None None None 2008 1400A-DE003 Installed NO S/R 2-07A 0-1207A DPCo. None None None 2008 Installed NO S/R 2-07A DPCo. None None None 2008 Installed NO S/R 2-07A 0-1402A-H6 01402A-RI6 1207A DPCo. None None None 2008 S/R 2-07A ' Installed NO 1207A DPCo. None None None 2008 1400A-SR 15IIIIII Removed NO

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1769991,1777844, 3 of 9 117970A

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/10/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Condensate & Emergency Feedwater, ASME Class 3 5.

(a) Applicable Construction Code: USAS B3 1.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

S/R 2-07A-DPCo None None None 2008 Installed NO 1400ASR19 S/R 2-07A 1400A-SR-25 DPCo None None None 2008 Installed NO 1400A-DE039 S/R 2-07A-0 DPCo None None None 2008 S/R 2-07A- Installed NO 1400A-DE039 1207A- DPCo None None None 2008 SIR 2-07A-6 e Installed NO S 407AR6- DPCo None None None 2008 Corrected NO SR1402A-D41 S/4207A-DE#4 DPCo None None None 2008 Removed NO SIR 2-037--

S/R 01402A-DE05 2-07A-SI1-030 DPCo None None None 2008 Corrected NO ON 2C HS DPCo None None None 2008 Removed NO 008707A ON 2C HS DPCo None None None 2008 Removed NO 008807A S/R 2-07A DPCo None None None 2008 Removed NO 01400AH60 ON 2C HS DPCo None None None 2008 Removed NO 006407A

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1769991,1777844, 4 of 9 1 17R7941

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/10/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Condensate & Emergency Feedwater, ASME Class 3 5.

(a) Applicable Construction Code: USAS B331.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

ON 2C HS DPCo None None None 2008 Removed NO 008907A 2-07A S/R07A DPCo None None None 2008 Removed NO 0-1400A-H61 ON 2C HS ON62C7HSDPCo None None None 2008 Removed NO 006507A S/R 2-07A £ 2-07A DPCo None None None 2008 Removed 0- 1400A-1-62 NO ON 2C HS *DPCo None None None 2008 Removed NO 006607A S/R 2-07A 2-07A DPCo None None None 2008 Removed 0- 1400A-H63 NO S/R 2-07A-6--

SI 407A DPCo None None None 2008 Corrected NO 0- 1400A-H65 S/R 2-07A 0-07A-6 DPCo None None None 2008 Installed 0- 1400A-H76 NO S/R 2-03A 2-03A-HI8- DPCo None None None 2008 Installed 0- 1400A-1-98 NO SIR 2-07A-I 207A- DPCo None None None 2008 Removed 1400A-H4291 NO SIR 2-07A-1207A- DPCo None None None 2008 Installed 1402A-H4292IIIIIII NO SIR 2-07A-1207A-HI3 DPCo None None None 2008 1402A-H4293 Installed NO

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 176999 1,17778~44, 5 of 9 17R7QAi1

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/10/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Condensate & Emergency Feedwater, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xi Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

S/R 2-07A-1402B-H4300 DPCo None None None 2008 Installed NO S/R 2-07A- '

1402-07A- DPCo None None None 2008 140213-1-4301 Installed NO S/R 2-07A-1402-07A- DPCo None None None 2008 Corrected NO 1402B-H4302 1207A- DPCo None None None 2008 1402B-H4303 Installed NO S/R 2-07 A-S207A- DPCo None None None

.1400A-H4304 SIR 2-07 A- 2008 Installed NO SIR 2-07A- DPCo None None None 2008 SIR 2-07A- Installed NO 1400A-H4305 1400A-07A- DPCo None None None 2008 1400A-H4306 Corrected NO sIR 2-07A-l207A- DPCo None None None 2008 1400A-H4307. Installed NO SIR 2-07 A-S4002-07A- DPCo None None None 2008 Corrected 1400A-H4308 NO SIR 2-07A-1207A- DPCo None None None 2008 Installed

!400A-H4309 NO 2-07A-'

S/R 2-07A- DPCo None None None 2008 Corr ected NO 1400A-H4310 DPCo S/ None None None 2008 Installed NO 11400A-1-4311 IIIIII

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI U.

Work Order Number Sheet 1769991,1777844, 6 of 9 17R70I

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/10/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Condensate & Emergency Feedwater, ASME Class 3 5.

(a) Applicable Construction Code: USAS B 31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)

S/R 2-07A-207A- DPCo None None None 2008 Corrected 1400A-H4312 NO S/R 2-07A- *o 1207A-4.13 DPCo None None None 2008 Corrected NO 1400A-H4313 S4002-07A- DPCo None None None 2008 Installed NO S/R 2-07A-1400A-H4314 1207A- DPCo None None None 2008 1400A-H4315 Installed NO S/R 2-07A-S4002-07A- DPCo None None None 2008 Installed 1400A-H4316 NO S/R 2-07 A-S/R 2-07A-I i 400A-H4319 1207A-H 0 DPCo None None None 2008 Installed NO S/R 2-07A-1400A-H4319 N

S/R 2-07A-l203A- DPCo None None None 2008 Installed NO 1203A- DPCo None None None 2008 1400A-H4322IIII Installed NO S/R 2-03A-DPCo None None None 2008 Installed NO 1400A-H4323 SIR 2-07A- 'I None None DPCo None 2008 Installed NO 1400A-H4324 d & ~ -. ,l -

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Number Sheet 1769991,1777844, 7 of 9 1787941

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/10/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Condensate & Emergency Feedwater, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

S/R 2-07A-1402-07A- DPCo None None None 2008 140213-H4325 Installed NO S/R 2-07A- E I 207A- DPCo None None None 2008 1400A-H4340 Installed NO SIR 2-03A-1203A- DPCo None None None 2008 1400A-H4359 Installed NO S/R 2-07A- t DPCo None None None 2008 Installed NO 1400A-H4385 ON O2C 2C HS DPCo None None None 2008 Installed NO 021907A 1207A- DPCo None None None 2008 SIR 2-07 A- Installed NO 1400A-H4386 1207A- DPCo None None None 2008 1400A-H4387 Installed NO SIR 2-07A-a S/ DPCo None None None 2008 Installed NO 1400A-H4388 1207A- DPCo None None None 1402A-H4339 2008 Installed NO SIR 2-07A-DPCo S/ None None None 2008 Installed NO 11402A-1-4294 SIR 2-07A-DPCo None None None 2008 Installed NO 1402A-H4295 t .t * +

2008 I Installed I NO lw SIR 2-07A- None None DPCo None None None None 2008 Installed NO 1402A-H4296

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Y --

Work Order Number Sheet 1769991,1777844, 8 of 9 17R7TAI

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/10/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Condensate & Emergency Feedwater, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

S/R 2-07A-1207A- DPCo None None None 2008 Installed NO 1402A-H4298 0-0A- 1 DPCo None None None 2008 S/R 2-03A- I- Removed NO 0-1400A-H 126 2-03A- DPCo None None None 2008 0- 1400A-H 127 Removed NO SIR 2-03A S/R 2-03A- l-N 0- 1400A-H 129 SI420A DPCo None None None 2008 Removed NO 0-140OA-HI30 SIR 2-03A-I-SI420A--0 DPCo None None None 2008 Removed NO SR-3--* DPCo None None None 2008 Installed NO 0-140OA-HI104 I I I I

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1769991,1777844, 9 of 9 1 ....

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Installed piping; (4) 30", (8) 20", (6) 8", (2) 6" & (1) 2" flange(s); (224) 1-1/4", (224) 1-1/8", (96) 3/4" & (16) 5/8" nuts & studs 0

0 0

0 0

0 0

CERTIFICATE OF COMPLIANCE Icertify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable' Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed .)U L6-x ,Terdi Spip fU. Date _______________

Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .rA],,' *,4.eo.-,iA and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period Z -Z 7- D to /-,2/- , , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_________________ Commissions ,__._.__,_______-_

"---T--pector's Signature National Board. State, Province, and Endorsements 9

Date /-2/- ,*

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI

- U - -

Work Order Number Sheet 01778488 I of 2 "1. Owner 2. Plant Unit Duke Energy Carolinas, LLC Oconee Nuclear Station ONS - 0 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 Nov. 18, 2008

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Energy Carolinas, LLC Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class SSF CCW, ASME Class 3 5.

(a) Applicable Construction Code: ASME Section III 19 86 Edition, A86 Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XA Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Code Component Manufacturer Serial Number Board No. Identification Built Removed, Stamped (Yes or INo)

Installed SSSF Service Water PO # N59200-16 Air Ejector Graham 65512-1 16556 Drawing NU-D- 1988 Removed YES ONOCCWAE001) Manufacturing123-1 0 SSF Service Graham PO # N59200-16 Water Air Ejector 65512-1 16556 Drawing NU-D- 1988 Installed YES (NCCWAE00) Manufacturing1123-1

7. Description of Work Testing had indicated potential degraded performance of the SSF Air Ejector, resulting in WO 01778488 to inspect/repair and replace parts as needed. Identical replacement parts were obtained under PO 108216 (and 108215). Inspection under the WO revealed no actual problem with the air ejector. Some parts were replaced for incidental reasons as indicated below (see Cat IDs in remark 1).

The Diffuser Pipe was replaced due only to the fact that the removed Diffuser Pipe flange weld build-up material interfered slightly with one of the Air Chamber Nuts during disassembly. The old Diffuser Pipe was otherwise acceptable and could have been re-used. (WR 00967924 was issued to machine the old Diffuser Pipe flange weld to remove a small amount of weld build up to eliminate the interference, then return to stock.) The Air Chamber Studs, Air Chamber Nuts, flange studs & nuts were replaced due to normal surface rust. All were in acceptable condition as previously installed. Gaskets and washers were also replaced. AlL replacements were with approved parts under Cat IDs established to duplicate the originals.

  • r

Order Number Sheet Work Order Work Number Sheet 01778488 2of 2 Test Conducted L- Hydrostatic E] Pneumatic -- Nominal Operating Pressure [I Exempt X Other F/V Leak Check Pressure n/a PSI Test Temperature n/a OF

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Portions of the SSF Service Water Air Ejector (ONOCCWAEOO1) were replaced with new parts as follows:

- Diffuser Pipe (one): Cat ID 864497

- Air Chamber Studs (eight): Cat ID 864739

- Air Chamber Nuts (eight): Cat ID 864741 The attached NSC Receiving Inspection Reports for PO 108216 provide additional information for air ejector parts replaced.

Also replaced were the studs and nuts connecting the air ejector to three adjoining pipe flanges:

- flange studs (twelve): Cat ID 297411; Threaded Rod; 1/2"; 13 UNC-2A; Alloy Stl; ASME SA193 GR B7; 1007B1ARICOA004; A, ASME Section III Subsection NB; UTC Nbr 001847391

- flange nuts (twenty four): Cat ID 313135-1; Heavy Hex; 1.2"; 13 UNC-2B; Carbon Stl; ASME SA194 GR 2H; ANSI B 18.2.2; AMSE Section III Subsection NB, 1007B2ANICOA004, A; UTC Nbr 0001894531 Gaskets and washers were also replaced with approved parts.

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Signed __

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of AJe ,,,q,, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period __ -/______to /-/.g - o0' , and state that to the best of my knowledge and belief, the Owner has performed examinations 'and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed. or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a ..loss of.any kind arising from or connected with this inspection.

_____________________ Commissions ,V/-/*Y KJ/A3.,'C

`'-"Inspector's Signature National Board, State, Province, and Endorsements Date /'A*--c7

611-Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1783520 I of 2 1

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station 0NS - 0 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/26/2009
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 3 (a) Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year CorrectedI ASME Component Manufacturer Serial Number Board No. Identification Built Removed-, Code or Installed Stamped (yes_No)

P LPSW-26 Allis-Chalmers Unk. Unk. None 1968 Removed LPSW-26 Enertech 11336 None None 2004 Installed YES

1) Piping , DPCo.- None None None 2008 Installed ....

LPSW- H189 BNL Industries A0800121-28-7 N/A 2008 Installed. YES--

LPSW-l 190 BNL Industries A0800121-28-6 N/A 2008 Installed YES

2) S/R'I-14B- ..

200B-5R3 DPCo None None None Ukn Corrected NO 400B3-SR3

3) S/R 2-14B- DPCo None None None Ukn Corrected NO 400B-DE 105

.. .. . ... . ". . . . '- . .. -- i - . . . . . .

7. Description-of Work~ - oa ....
lej*ai6ýdLLPSW-26:aiii'dipipini sp-6i-piece'between LPSW-26 and LPSW-25, installed two new 2" drains, one with... .

valve LPSW-1 189 and the other with LPSW-1 190 and installed a reinforcement tee with seal-tite and blind flange.

8-.- Tpest Conducted -- - .

Hydrostatic. - Pneumatic N-Nominal Operating7Pressure- -F-] Exempt El Other -

Pressure PSI Test Temperature _F

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI _-

Work Order Number Sheet 1783520 2 of 2 Reports to be attached)

9. Remarks (Applicable Manufacturer's Data o Replaced two 24" slip-on flanges and short length of 24" pipe, installed re-inforcement tee, 24" blind flange, two 2" half couplings 2" pipe and two 2" pipe caps. Replaced 1-1/4" 8UN threaded rod (studs) UTC #1847398, 1-1/4" 8UN Heavy Hex Nuts (UTC #1915241), 1-1/4" 7UN threaded rod (studs) UTC #1822336, 1-1/4" 7UN Heavy Hex Nuts (UTC #1092153).
  • Added 4"x4"x3/8" angle (UTC #1088234) and 3"x3"x3/8" angle (UTC #935012), modified weld between Item 2 and existing Col.

O Lengthed weld on Item 7 to existing Col.

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable - "

Signed .j Date / --

Owner or O7;er's Designee, Title/

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Provinceof &: - ,- and employed by HSB CT ..

of Hartford, Connecticut have inspected the components described in this Owper's Reportduring the period .- . . f-,a-y to_/-*?..,f ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance, with the requirements, of the ASME Code,Section XI.

By signing this ificat0oithrga he lse~tbrnhi*-e/po'rmkes any warranty, expressed br imnplied, concerning the examinations. and corrective measures described_ in this Owner's Report. Furthermore, neither the Inspector- nor his--empilyer s ai- be-liabl-e.in- nymnan-er-for any- personal _injury or property damageor a loss .of-any kind arising frohn or co-nnected witfiththis inspec-tion..... .. ....... .. . ." " . ..

  • - - ~Commissions AACa~c
  • .. '.. nspector's'Signature . - - National Board, State, Province,: and Endorsements Date / "e*o-

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisigns of the ASME Code Section XI Work Order Number ýSheet 01794494-01, -04, -07 1 of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 0 526 South Church Street

.--.. 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/19/2008

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class SSF CCW, ASME Class 3 5.

(a) Applicable Construction Code: ASME Section III 19 74 Edition, 1975 Addenda, Code Case (b) Applicab!e Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s)

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 7SSF Aux Service Water Strainer Zum 29 9808 Model 8-563 1980 Corrected YES (1)

-t -t 1~ -t -t t I I -t -t I I $

& & & I &~& I

7. Description of Work The SSF Aux Service Water Strainer is a duplex strainer that contains 2 valve Discs that seal against Spacer Plates to allow for isolation of one strainer basket or the other. The corroded lands either side of the o-ring groove in the valve discs were be built up by welding and then machined to the nominal new height and the o-ring groove re-machined into khe disc. The corroded sealing surface face of the Spacer Plates were skim cut to re-establish a suitable surface condition o improve sealing of the disc o-ring against the plate. Also, the Operator End Seal Plate was replaced.
8. Test Conducted E Hydrostatic n Pneumatic 0 Nominal Operating Pressure El Exempt Other Pressure PSI Test Temperature i. OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 1 01794494-01, -04, -07 2 of 2 Manufacturer's Data Reports to be attached)

9. Remarks (Applicable
9. Remarks (Applicable Manufacturer's Data Reports to be attached) o The 2 valve discs to the SSF Service Water Strainer had corroded o-ring grooves. Weld metal was added to the groove area and machining performed to re-establish proper groove dimensions. The 2 spacer plates, which are the mating surfaces for the valve discs, were also corroded. Machining of the spacer plate to re-establish smooth sealing surfaces was performed.

0 Part #28 on OM 240.-044.001 replaced like for like with manufacturer part 83762-1. This was item was stock code 863210:

PLATE, END, CARBON STL, SA-515, GR 70 with the condition of QA-1, UTC Nbr: 1915738, PN#83762-1 and HT#801B04680.

0 0

0 0

0 0

0

/

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed A r Date Q/6OV. 2-3, 20o0.

Owner or Owner's Designee, Ti-te CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province off, -",o_ and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period //- /8 - o0 to /-* - 0 f , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any rind arising from or connected with this inspection.

  • *-2 /' Commissions ,/* .- ,t

- Inspector's SignatUre National Board, State, Province, and Endorsements Date /-_ __ __O__

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Work Order Number Sheet 01797845-01 I of 2 mu - I.

IW1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 11/19/2008

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class High Pressure Injection, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed- Stamped (Yes I No) 121-IP-7 CCI Unknown N/A None 1998 Corrected NO
7. Description of Work PM of the valve revealed that the spindle was eroded on it's seating surface that interfaces with the seat ring.

-Maithienance-had to-replace the spindle.

8. Test, Conducted& - .

.L Hydrostatic L-]Pneumatic -I Nominal Operating Pressure -' Exempt [ Other Visual Pressure PSI Test Temperature OF

,Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl Work Order Number Sheet Af 1 /'7079A< A1 I 1) ,-.f -)

Remarks (Applicable Manufacturer's Data Reports to be attached) o Valve Spindle, Cat ID 480657, UTC #0001916091, HT # A899, Material - SB637-N07718, Serial # I 0

0 0

o+q CERTIFICATE OF COMPLIANCE I certify that the statements m ade in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Si~nedj~.A&)14Owner or Owner's Designee, Title Dt CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of /o,-,, ,, and employed by HSB CT of .... Hartford,Connecticut have inspected the components described.

in this Owner's Report during the period //- -f -06 to /F/9E *' , and state that to.-the. best.-of.., my..knowledge-and, belief, -the. Owner has performed examinations and taken corrective measures described .in .this.Owners..Report-in accordance.with the requirements of the ASME Code, Section Xl.

-. By signing this-.certificate--neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owners Report. Furthermore, neither the Inspector-nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kir.d-.arising::from-o[rconnected-w.ith thisinspection.

-Commissions 4Wc Z~Yr 7:1 ector's Signature p"-.. National Board, State, Province, and Endorsements 0

Date _ - I ..

SFourm NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI WOrK uroer Numoer Sheet 01797924-01, -10 1 of 2

--.--.Ow ner- - " -. - 2. Plant . -- Unit Duke Power Company Oconee Nuclear Station ONS - 2 L - -:.::5dS0.UhChurch Str~eet .. 5-.2,,:*'1:-t , 70 Rochester Hwy -Date ...  :

Charlotte, NC 28201-1006 Seneca, SC 29672 11/13/2008 3.- Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable

4. Identification of System, ASME Class 2A Reactor Building Cooling Unit (RBCU) Coils, ASME Class 3 5.. ..

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME
  • Component Manufacturer Serial Number Board No. Identification Built Removed, Code

- or Installed Stamped (Yes I No) 2A RBCU-Coils Aerofin 940505, 550,551,556 None 1994 Corrected YES 1, 2, & 3 (1) Corporation 940506, 940511 5 5 5o1red

7. Description of Work PM on the 2A RBCU Coils # 1, #2 and #3 (tube cleaning and eddy current testing) required disassembly/reassembly of the cooler channel head. This involved disassembling the Low Pressure Servcie (LPSW) piping from the coils. The 5/8-inch diameter LPSW piping bolting material for the piping-to-coil flanges required replacement due to surface degradation. Note, the #4 coil was not PM'd this outage and therefore no disassembly was required on this coil.
8. Test Conducted E[- Hydrostatic 1 Pneumatic [ Nominal Operating Pressure 1 Exempt [I Other Pressure _ PSI Test Temperature OF

form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order 1797924 0 -------iIj Numfiiber.*


. Sheet -.........

2 --- -------

-9.-Remarks (Applicable Manufacturer's Data Reports to be attached) ... -..-..

o Replaced ninety-six (96) 5/8-inch diameter nuts and forty-eight (48) 5/8-inch diameter studs on the 2A RBCU, #1, #2 and #3 Cobils'-flamnges (UTC # 0001908177, Stock Code 293556, and UTC #-0001909601 & 000191 _776,*~S kC6"#297 412).

~0 0__.

0 o

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signet 411uieA - riainee,- Date f/14 /Zoc'8 Owner or Owner's Designee, Title/

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /'o-e. 7-o& to /-/ 0-c' , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

___________________ Commissions A/IC 7,,.,,i Inspector's Signature National Board, State, Province, and Endorsements Date / I-

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01798051-01 1 of 2

-- - I. -~ I

1. Owner 2.: Plant :Unit.=:- :-  :-=-  :.

.Duke Power Company Oconee Nuclear Station ONS- 2

.526 South Church Street 7800 Rochester Hwy Date

-Cliarlotte,NC 28201-1006 Seneca, SC 29672 i11/6/ 27070-8

3. Work Performed by Type Code Symbol Stamp Not Applicable

'Duke Power Company Authorization Number . .. -

526 South Church Street Not Applicable

-- -Charlotte, NC 28201-1006 Expiration Date ------

Not Applicable

4. Identification of System, ASME Class Main Steam, ASME Class 3 5.

(a) Applicable Construction Code: USAS 1331.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl'Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No) 2MS-87 Fisher Controls 4792779 N/A None 1970 Corrected NO
7. Description of Work The valve plug/stem assembly was replaced during 2EOC23 outage due to eroded valve plug from flow conditions.
8. Test Conducted E]Hydrostatic Pneumatic 1:1 Nominal Operating Pressure LI] Exempt N Other Visual Pressure PSI Test Temperature _F

Form NIS-2 Owner's Report for Repair/Replacement Activity srequired by the provisions of the ASME Code Section XI

.* , " -Work Orde r -Number Sheet 01'7 9.8051-O1 2 of 2

9. Remarks (Applicable Maniifacturei'sDat=Ritpoitpfo be ttfiched) .--

O Valve plug, UTC #-0001091641, Catalog ID # 279942, HT # A15257, Fisher part #1 P3918X0132--- a[ /0 ( r o -

G 0 .- ...

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed Date //- -*>

,ý*oner or Owner's Designee, Title 17 CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of .,-.W , and employed by. HSB CT of . Hartford, Connecticut , have inspected the components described in this Owner's Report during the period / ;- .- .. , to I-eo - V7 7 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions ,/ 4'*4'-

- N1-peetor's Signature National Board, State, Province, and Endorsements Date C-'Q-

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI U

Sheet IWork Order 01798554-06 Number 1 of 2

1. Owner 12. Plant Unit Duke Power Companyj Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 1 Seneca, SC 29672 1/06/09
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class 2B2 RCP COOLER SHELL RELIEF VALVE, ASME Class c 5.

(a) Applicable Construction Code: USAS B331.7 19 68 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed -Stamped (Yes / No) 2 147H9G- D.E.C. NONE NONE NONE 1973 Corrected NO I .4 1 1. .4 .4 .4 4 .4 & A. .4 .4 .4 a s I J. .1 1 1 r I I *I* a a a

______ I _____ ______ I _____ I ______ ___ I _____

i I 1d

7. Description of Work Installed new material for items 14,19, and 22. Performed welding-forstructural attachments of items 2,3,14,t19,2-Bases metal repair to structural steel all as part of re-instalktion aihd n6tmal-wear anid tear.

m a

8. Test Conducted .. . . .. . . -. .. ... = = " "'"

L" Hydrostatic []Pneumatic []Nominai Operating Pre-.ure Exempt- [-]Other Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI Work Order Number -. Sheet 01798554-06 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Flat I"x3" bar UTC# 0001081518 Trace: M HT#V4-3389 O l-l/2"x3"xl'-4" plate UTC# 0001913383 Trace: M HT#7109236 O 1/2"x2" flat bar UTC# 0001893033 Trace: M HT#77420 o Weld BMR-I UTC# 1919516, weld BMR-2 UTC# 1919516, weld BMR-3 UTC# 1919516, weld 19 to 2 UTC# 1919516 0 Weld 19 to 3 UTC# 1919516, weld 19 to 2 UTC# 1919516, weld 14 to 2 UTC# 1919516, weld 14 to 3 UTC# 1919516 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed 7-iRAJ~ Engineer Date 1/5/2009 Ownef or Owner'9 Designee, Title CERTIFICATE OF INSERVICE INSPECTION 1,the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of floe rl c-vs and employed by HSB CTr of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ___________to /..eO.. 0? ,and state that to-Ahe -best-,of -my-~knowledge -and belief, the Owner has performed examinations%and taken .corrective~-measuresý

- -described in-this Owner'sLReport in accordance with the requirements of the ASME Code, Section Xl.- _

..By signing tis etfct ete h Inspector nor his employer makes any warranty,. expressed or implied,~

-concerning -the examinations- and- corrective measures described in this Owner's Report. Furthermore, neither-the-Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss. of any,

_kinid ~isn~rmo once ith this inspection.

_______________________Commissions A/C. ~~5<,'C Inspector' s.Signamure National Board, State, Province, and Endorsements.

Date 6Z

ý- 7

Fdim NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl Work Order Number Sheet 01799268 I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1/5/2009
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not.Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Low Pressure Service Water, ASME Class 3 5.

(a) Applicable Construction Code: USAS B33 I. 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section X1 Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

+ t 4 W

I. Piping DPCo. None None None Unk Installed NO

2. 2-1413 14B913- None None None None Unk Removed NO 1439B-H 18 3.3913-1-118 2-1413 None None None UTC1832152 2008 Installed NO 1439B-HI8
7. Description of Work OE202127 (EC97358) replaced 8" LPSW piping.
8. Test Conducted D Hydrostatic F-I Pneumatic Nominal Operating Pressure L Exempt El Other Pressure PSI Test Temperature OF

Form'NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Work Order Number Sheet 1 01799268 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o None 0 None O Changed 1/2" plate from CS to SS SA240, TP304.

0 0

0 0

§

§ CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed - Mechanical Engineer Date 1/5/2009 OvOwner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of , --,, , and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,-,$-o*: to --... "* o ,2" ,and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

_________________ Commissions __.________-_-____

Inspector's Signature National Board, State, Province, and Endorsements Date e/ - o

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI

-U. -

C-l Work Order Number Sheet

01. Owner 2. Plant 01802903-12 Unit I of 2 Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201 - 1006 Seneca, SC 29672 4/14/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Essential Siphon Water, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.l 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No)

ESV2 Crispin- 20312-3 None None 2000 Corrected NO Multiplex MFG

7. Description of Work Replace the existing 2ESV-2 with spare valve from the warehouse F8. Test Conducted

- ]Hydrostatic 111 Pneumatic 1: Nominal Operating Pressure --] Exempt Other Visual Pressure PSI Test Temperature OF

Form'NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 2 of 2 0 1 01802903-12 I 2 of 2 U-W. Remarks (Applicable Manufacturer's Data Reports to be attached) 01802903-12 0 DMV-1231, Replaced Entire valve, Catalog 462323, UTC # 0001026261 0 -MLAC C O 0

0 I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed ,AA J Date

° Owner or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A,,'Oe.r CAo9,~vq and employed by HSB CT of Hartford, Connecticut have inspected the components describe d A

in this Owner's Report during the period 3 -2 7- oa° to --..- " , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions A,/.)C4"*V 1de,

  • Inspector's Signature National Board, State, Province, and Endorsements Date R-'-e-g

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI U

Work Order Number Sheet 1811479-02 I of 2 Ah

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 0 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 7/01/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Essential Siphon Vacuum System, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.1 19 67 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No) 0 ESV PU 0001 Siemens 231842 UJNK None 1996 Corrected NO
7. Description of Work The existing pump was removed to be rebuilt and replaced with an in house spare pump. This form covers the rebuilding of the removed pump which will now be the spare.
8. Test Conducted

-- Hydrostatic I-ElPneumatic [ Nominal Operating Pressure L Exempt [i Other Pressure PSI Test Temperature OF ..

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section X1 Work Order Number Sheet 21 A170-0) I 9 Af" 9

- Remarks (Applicable Manufacturer's Data Reports to be attached) 0 0

0 0

0 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate oy uthorization Number Not Applicable Expiration Date Not Applicable Signed Engineer Date 7/1/2008

w. er or Owner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of A,,oR*l ,,eZ.,,,Au and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period 7- Z - o6 to f-?. V-o.8 , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

____________________________Commissions __

Inspector's Signature National Board, State, Province, and Endorsements Date 0

Form NIS-2 Owner's Report for Repair/Replacement Activity C-As r-quired by the provisions of the ASME Code Section XI Work Order Number Sheet 01831432 1 of 2

/

0

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/10/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class RC, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section Xl Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 1.) 57-0-1481A-H4 DPCo None None None UNK Corrected NO
7. Description of Work OE201906 (EC95380); S/R 57-0-1481 A-H4- Temporarily remove and reinstall due to replacement of RCPM 2B 1.
8. Test Conducted

" Hydrostatic [-- Pneumatic E] Nominal Operating Pressure N Exempt Li Other Pressure PSI Test Temperature OF ,

Form NIS-2 Owner's Report for Repair/Replacement Activity

/.s required by the provisions of the ASME Code Section XI I I Work Order Number Sheet 01831432 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o 57-0-148 1A-H4; 1/2" and 3/4" plates, 1" diameter rods with nuts and washers.

0

§ 0

0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not. Applicable Signed Oweror"" nerDes Title ,A- Date /,/a- d t.v4 -. Tt CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of _,.,4, wvoberA'//",,and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,' -/o - o to 75-?J.o , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code,Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions

- '----JIfspector's Signature National Board, State, Province, and Endorsements Date It

Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisioris of the ASME Code Section XI.

9 .. Work Order Numbe 01831432 - 33 Sheet Pagel of 2 1.Owner Duke Power Company 2.Plant Oconee j Nuclear Station unit 2 526 South Church Street 7800 Rochester Hwy*

Date 12/2/2008 Charlotte, NC 28201-1006 Seneca, SC 29672-0752

3. Work Performed By Type Code Symbol Stamp I Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of Systems, ASME Class Vents - Reactor Bldg. Components

, ASME Class 3

5. 1 (a) Applicable Construction Cod USAS B31.1 1967: Edition, No Addenda No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 1998: Edition, 2000 Addenda (c) Applicable Section XI Codes Cases(s) None
6. Identification of Coimponents Name of Component Manufacturer: Manufacturer National Other Year Corrected, ASME Code Serial Number Board No identification Built Removed or Stamped Installed (Yes/No)

(1) 57-0-1481A-H7, Load Pin N/A N/A UNK N/A UNK Removed No 7-0-1481A-H7, Load Pin Anvil -5t4"27217 UNK UTC 09 3 3 6 0 UNK Installed No 4 r /4 11

  • t,,* o
7. Description of Work Replace existing load pin with a double end load stud.
8. Test Conducted D Hydrostatic D Pnuematic [ Nominal Operating Pressure ED Excempt [ Other Visual Pressure PSI Test Temperature Deg. F

'V .

Form NIS-2 Owner's Report for Repair/Replacement Activities As required by the provisions of the ASME Code Section Xl Work Order Numbe Sheet 0 1 01831432 - 33 Page 2 of 2

7. Remarks (Applicable Manufactuerrs Data Reports to be attached)

(1) Replace existing load pin with a double end load stud.

CERTIFICATION OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl Type Code Symbol Stamp Not Applicable Certificate of Autherization Nupnber Not Applicable Expiration Date Not Applicable Signed __ _ _ _ _ _ __ _ _ _ _ _Date _ _'_ _

Owner or Owner's Designee, Title CERTIFICATION OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and State or province of A.1,,4* .er

  • 4,,-.v and employed by HSB CT of Hartford, Connecticut have inspected the components described in the Owner's Report during the period / ?- - e.- 0T to /-1,-o Y , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section Xl.

By signing this certificate neither the inspector nor his employer make any warrenty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind rising from or connected with this inspection.

Commision(s) / _./

Inspector's Signature National Board, State, Province, and Endorsements Date

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASMIE Code Section XI Sheet IWork Order01831432 Number I of 2

1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 1-6-2009
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class ON 2 GWD HS 000557, ASME Class '* '

5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes I No) 0-4 A 5; H0-148IA- D.E.C. NONE NONE NONE 1973 Corrected NO 1 9 4 4 4 4 4.

______.~

7. Description of Work I ______

1 ill..i

~ ___

i~~i Repaired weld 7..

8;. Test Conducted

[]Hydrostatic Lii Pneumatic LINominal Operating Pressure Exempt El Oiher Pressure PSI Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI I I Work Order Number Sheet 01831432 2 of 2

9. Remarks (Applicable Manufacturer's Data Reports to be attached) o Weld 9 to 8 UTC1914216 0

0 0

0

§ Q) 0 CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed *__1 fr Engineer Date 1/6/09, O.wner or bwner's Designee, Title CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,,, e7-r'. /,, and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period ,/-/o *, *' to /- 00o - 07 , and state that to the best of my knowledge and-belief1-- the -Owner--has, performed examinations--and Aaket corrrective-measures described in this Owner's Report in-accordance with theiequirements-of-the ASME Code, Section XL-- -_ .

By signing this certificate neither the Inspector nor his employer makes .any warranty, expressed or implied, concerning the examinations and-corrective measures-described in-,this. Owner's Report;--Furthermoreneither--the Inspector nor his employer shall be liable in any manner-for any personal injury or property damage or a loss of any kind arising from or connected witht his .inspection= - . -...--

Comm iss ions .:A&- -ý Inspector's Signature National Board, State, Province, and Endorsements .

Date e/-- -c3

C Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 01831432 I of 2 E~,

I

- Unit

1. Owner 2. Plant Duke Power Company Oconee Nuclear Station ONS- 2 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/10/2008
3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class HPI, ASME Class 3 5.

(a) Applicable Construction Code: USAS B31.7 19 69 Edition, No Addenda, No Code Case (b) Applicable Edition Section XI Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No) 1.) 2-51-1479F- DPCo None None None UNK Corrected NO H6445
7. Description of Work OE201906 (EC95380); S/R 2-51-1479F-H6445- Temporarily remove and reinstall due to replacement of RCPM2B1.
8. Test -Conducted D Hydrostatic E Pneumatic .. 1" Nominal Operating Pressure - Exempt LI Other Pressure PSI, Test Temperature OF

Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section Xl I

Work Order Number Sheet 01831432 2 of 2

-I

9. Remarks (Applicable Manufacturer's Data Reports to be attached) 0 2-51-1479F-H6445: 1/4" plates 0

0 0

0 0

0 A

CERTIFICATE OF COMPLIANCE I certify that the statements made in the report are correct and that this conforms to the requirements of the ASME Code, Section Xl.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed ______-_,___ _____-,____ -.,__. ___, Date /Z.. Lo 0

!Owne( or Owner*AI'ignee, Title 19":d s .

CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State orProvince of A/:,z,,cwo and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period /L- ,V -OCR to ,,./'- Y' , and state that to the best of my knowledge and belief, the Owner has performed examinations and taken corrective measures described in this Owner's Report in accordance with the requirements of the ASME Code, Section XI.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection.

Commissions -VL-W3,*,/dJ -

Inspector's. Signature National Board, State, Province, and Endorsements Date /-/-0 57

.Form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI p

Work Order Number Sheet 01843163 1 of 2

'1. Owner 2. Plant Unit Duke Power Company Oconee Nuclear Station ONS - 0 526 South Church Street 7800 Rochester Hwy Date Charlotte, NC 28201-1006 Seneca, SC 29672 12/10/2008

3. Work Performed by Type Code Symbol Stamp Not Applicable Duke Power Company Authorization Number 526 South Church Street Not Applicable Charlotte, NC 28201-1006 Expiration Date Not Applicable
4. Identification of System, ASME Class Condenser Circulating Water, ASME Class 3 5.

(a) Applicable Construction Code: USAS B331.7 19 69 Edition, No Addenda, None Code Case (b) Applicable Edition Section Xl Utilized For R/R Activity 19 98 Edition, 2000 Addenda.

(c) Applicable Section XI Code Case(s) None

6. Identification of Components Name of Name of Manufacturer National Other Year Corrected, ASME Component Manufacturer Serial Number Board No. Identification Built Removed, Code or Installed Stamped (Yes / No)

Station Auxiliary Ingersol-Rand Service Water Pump Suction (Currently 0869073 None None UNK Corrected NO Flange and Piping Flowserve)

7. Description of Work The flange studs that connect the Station Auxiliary Service Water Pump suction flange to the Station Auxiliary Service Water Pump suction piping.spooLpiece-flange-were replaceL.....

The flange.studs-..that coniect, theStaticinS Auxiliary Service Water Pump suction piping spool piece flange.to the suction valve flange were also replaced_. .

The gaskets were replaced in these flan-ges with-thicker gaske*t. Thig-resulte-d -in the-need-for longer studs to meet -

minimumbthread-engagme...nt..

8. Test Conducted .

li Hydrostatic E] Pneumatic n Nominal Operating Pressure . - Exempt n Other Visual Inspection-Pressure PSI Test Temperature OF

form NIS-2 Owner's Report for Repair/Replacement Activity As required by the provisions of the ASME Code Section XI Work Order Number Sheet 2 of 2 I- 1 01843163 2 of 2 U Uv9. Remarks (Applicable Manufacturer's Data Reports to be attached) 01843163 0 Replaced all 7/8" studs on the Station Auxiliary Service Water pump suction flange to suction piping flange.

0 Replaced all 1V studs on the Station Auxiliary Service Water pump suction piping flange to the suction valve flange CCW-99.

0 0

0r 0

CERTIFICATE OF COMPLIANCE I certifythat the statements made in the report are correct and that this conforms to the requirements of the ASME Code,Section XI.

Type Code Symbol Stamp Not Applicable Certificate of Authorization Number Not Applicable Expiration Date Not Applicable Signed C.

C. , f 4.. L-" -. Senior Technical Specialist Date 12/10/08 Owner or Owner's Designee, Title CERTIFICATE OF INSERVICEINSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State or Province of ,,x4-,,/ t-: and employed by HSB CT of Hartford, Connecticut have inspected the components described in this Owner's Report during the period // -Z,-o5 0 to /.-Zo - 0,P , and state that to. the best of-my knowledge-and ..belief,- 1he.iOwner=hasperformed examinations and .takew -corrective measures described in thi.sOwner's Repojrtin accordance withtbe_:requirements_ of the ASME Code, SectionXl.

By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examin-ati"ns- an-d corrective masu-e. described-inthis Ow*v*ner-s -Repo-rt. uFthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property-damage or a loss of any kind arising from or corinected-with this inspection. - - .

Commissions . C

'* . pector's-Signature National Board, State. Province, and Endorsements Date /-I ' -" C , .7

Date: 01/05/09 Sheet: 1 of 1 TO: ONS ISIM Plan Manager FROM: ONS QA Tech. Support RE: PRESERVICE EXAMINATIONS OF CLASS 1 & 2 WELDS As required by ASME Section XI 1998 Edition with 2000 addenda. Pre-service examinations were performed on ISI Class 1 & 2 welds made during the U2EOC23 outage timeframe. The following is a list of the welds that received pre-service examinations during this outage timeframe.

WORK ORDER WELD NUMBER ISI CLASS INSPECTION TYPE NUMBER MT PT RT UT 1737591 2MS-0146 - 4 2 X X 1754287 2MS-0103 - 79 2 X X 1760949 2-53B-0017 2 X 176 2-53B-0017 2 X 176 & 179 2-53B-0018 73 2 X 1799867 2HP-0216 - 22 1 X 2RC-0203 - 32 1 X X 1799868 2HP-0217 - 21 1 X 2RC-0204 - 37 1 X 1841935 2RC-0266 - 24& 1 X 25

/

I I 1-4-1-4.-

I I 1-4-1 I I 1t1t I I 1-4-1 I I I I 1-4-1 I I I~t~I~t~

I I 1-4-14 I I 4-4-1 Revision 1: Deleted entry for welds associated with work order # 17443077 due to work not being completed. JRM 23 - 09 Prepared By: JRB5

6.0 PressureTesting The Class 1 (Category B-P) leakage test is required each refueling outage. Table 6-1 shows the completion data of the Class 1 (Category B-P) leakage test conducted during refueling cycle EOC23.

Table 6-1 DetailedClass 1 Listing EOC23 Zone Completion EOC23 VT-2 Code Case(s)

Number Boundary Dwg Status Examination Date Used OZ2L-1A O-ISIL4-100A-2.1 Complete 12/10/08 None O-ISIL4-10OA-2.2 Corn plete 12/10/08 None O-ISIL4-10OA-2.3 Complete 12/10/08 None O-ISIL4-101A-2.1 Complete 12/10/08 None O-ISIL4-101A-2.4 Complete 12/10/08 None O-ISIL4-102A-2.1 Complete 12/10/08 None O-ISIL4-102A-2.3 Complete 12/10/08 None O-ISIL4-1 1OA-2.1 Complete 12/10/08 None O-ISIL4-1 1OA-2.4 Complete 12/10/08 None OZ2L-1 6 O-ISIL4-101A-2.4 Complete 12/08/08 None The Class 2 (Category C-H) leakage tests are required each period. Table 6-2 shows the completion data of the Class 2 (Category C-H) leakage tests required for the 2 nd Inspection Period.

Table 6-2 Detailed Class 2 Listing VT-2 Code Zone Examination Case(s)

Number Boundary Dwg Completion Status Date Used 1 IZ2L-10 O-ISIL4-101A-2.3 Completed in EOC23 10/25/08 None 2 IZ2L-11 O-ISIL4-101A-2.3 Completed in EOC23 10/25/08 None 3 IZ2L-12 O-ISIL4-101A-2.3 Not Yet Tested O-ISIL4-101A-2.4 Not Yet Tested 4 IZ2L-13 O-ISIL4-101A-2.3 Not Yet Tested 5 IZ2L-14A O-ISIL4-101A-2.3 Completed in EOC23 12/01/08 None 6 IZ2L-14B O-ISIL4-101A-2.3 Completed in EOC23 12/01/08 None 7 IZ2L-20 O-ISIL4-101A-2.3 Not Yet Tested

-Refueling Outage Report EOC23 Page 1 of 4 Oconee Unit 2 Revision 0 Section 6 January 21, 2009

VT-2 Code Zone Examination Case(s)

Number Boundary Dwg Completion Status Date Used 8 IZ2L-22 O-ISIL4-101A-2.3 Not Yet Tested O-ISIL4-102A-2.1 Not Yet Tested O-ISIL4-102A-2.2 Not Yet Tested O-ISIL4-104A-1.2 Not Yet Tested 9 IZ2L-24 O-ISIL4-102A-2.1 Not Yet Tested O-ISIL4-103A-2.1 Not Yet Tested 10 IZ2L-25 0-ISIL4-102A-2.1 Not Yet Tested OI-ISIL4-103A-2.1 Not Yet Tested 11 IZ2L-27A O-ISIL4-102A-2.1 Not Yet Tested O-ISIL4-102A-2.2 Completed in EOC23 12/05/08 None 12 IZ2L-27B O-ISIL4-102A-2.2 Completed in EOC23 12/06/08 None 13 IZ2L-4 O-ISIL4-101A-2.1 Not Yet Tested 14 IZ2L-41 O-ISIL4-109A-1.1 Not Yet Tested 15 IZ2L-48 O-ISIL4-122A-2.1 Not Yet Tested O-ISIL4-122A-2.2 Not Yet Tested 0-ISIL4-122A-2.3 Not Yet Tested 0-ISlL4-122B-2.1 Not Yet Tested 0-ISIL4-122A-2.4 Not Yet Tested 16 IZ2L-5 O-ISIL4-101A-2.1 Not Yet Tested 0-ISIL4-101 A-2.3 Not Yet Tested 17 IZ2L-60 0-ISIL4-124B-2.2 Completed in EOC23 06/05/08 None O-ISIL4-124B-2.4 Completed in EOC23 06/05/08 None 18 OZ2L-14B O-ISIL4-101A-2.4 Completed in EOC23 12/01/08 None 19 OZ2L-15 O-ISIL4-101A-2.4 Completed in EOC23 12/10/08 None 20 OZ2L-16 O-ISIL4-101A-2.4 Completed in EOC23 12/08/08 None 21 OZ2L-17 O-ISIL4-101A-2.2 Completed in EOC23 12/08/08 None 22 OZ2L-17B O-ISIL4-101A-2.2 Partial in EOC23 11/30/08 None 23 OZ2L-18 0-ISIL4-101A-2.2 Completed in EOC23 12/06/08 None Refueling Outage Report EOC23 Page 2 of 4 Oconee Unit 2 Revision 0 Section 6 January 21, 2009

VT-2 Code Zone Examination Case(s)

Number Boundary Dwg Completion Status Date Used 24 OZ2L-19A O-ISIL4-104A-1.1 Not Yet Tested O-ISIL4-101A-2.5 Not Yet Tested 25 OZ2L-19B O-ISIL4-101 A-2.5 Partial in EOC23 11/27/08 None 26 OZ2L-1A O-ISIL4-101A-2.1 Completed in EOC23 12/10/08 None O-ISIL4-101A-2.5 Completed in EOC23 12/10/08 None 27 OZ2L-2 O-ISIL4-101A-2.1 Completed in EOC23 12/10/08 None O-ISIL4-101A-2.4 Completed in EOC23 12/10/08 None O-ISIL4-101A-2.5 Completed in EOC23 12/10/08 None 28 OZ2L-21 O-ISIL4-102A-2.1 Completed in EOC23 12/06/08 None O-ISIL4-102A-2.2 Completed in EOC23 12/06/08 None O-ISIL4-104A-1.2 Completed in EOC23 12/06/08 None 29 OZ2L-23 O-ISIL4-101A-2.2 Completed in EOC23 12/05/08 None O-ISIL4-102A-2.1 Completed in EOC23 12/05/08 None O-ISIL4-102A-2.2 Completed in EOC23 12/05/08 None 30 OZ2L-26 O-ISIL4-102A-2.2 Completed in EOC23 12/06/08 None 31 OZ2L-28 O-ISIL4-102A-2.2 Not Yet Tested 32 OZ2L-29 O-ISIL4-102A-2.2 Completed in EOC23 12/06/08 None 33 OZ2L-29A O-ISIL4-102A-2.2 Completed in EOC23 12/06/08 None O-ISIL4-102A-2.3 Completed in EOC23 12/06/08 None 34 OZ2L-3 O-ISIL4-101A-2.1 Completed in EOC23 12/10/08 None 35 OZ2L-30 O-ISIL4-102A-2.2 Completed in EOC23 12/06/08 None 36 OZ2L-30A O-ISIL4-102A-2.2 Completed in EOC23 12/06/08 None O-ISIL4-102A-2.3 Completed in EOC23 12/06/08 None 37 OZ2L-31A O-ISIL4-102A-2.3 Completed in EOC23 12/25/08 None 38 OZ2L-31B O-ISIL4-102A-2.3 Completed in EOC23 12/25/08 None 39 OZ2L-31C O-ISIL4-102A-2.3 Completed in EOC23 12/25/08 None 40 OZ2L-39 O-ISIL4-104A-1.1 Not Yet Tested 41 OZ2L-42A O-ISIL4-1 1OA-2.1 Completed in EOC23 12/10/08 None 42 OZ2L-42B O-ISIL4-11OA-2.1 Completed in EOC23 12/10/08 None

>1 Refueling Outage Report EOC23 Page 3 of 4 Oconee Unit 2 Revision 0 Section 6 January 21, 2009

VT-2 Code Zone Examination Case(s)

Number Boundlary Dwg Completion Status Date Used 43 OZ2L-44 O-ISIL4-1 1OA-2.1 Not Yet Tested O-ISIIL4-121 B-2.3 Not Yet Tested O-ISIL4-121 B-2.5 Not Yet Tested O-ISIL4-121D-1.2 Not Yet Tested 0-ISIL4-121D-2.1 Partial in EOC23 12/05/08 None O-ISIL4-122A-2.1 Not Yet Tested O-ISIL4-133A-2.5 Partial in EOC23 12/05/08 None 44 OZ2L-6 O-ISIL4-101A-2.1 Complete in EOC23 12/10/08 None O-ISIL4-101A-2.2 Complete in EOC23 12/10/08 None O-ISIL4-109A-1.1 Complete in EOC23 12/10/08 None 45 OZ2L-6B O-ISIL4-101A-2.2 Not Yet Tested 46 OZ2L-64 O-ISIL4-124B-2.2 Complete in EOC23 12/10/08 None 47 OZ2L-65 O-ISIL4-124B-2.4 Complete in EOC23 12/10/08 None 48 OZ2L-7 0-ISIL4-101A-2.2 Complete in EOC23 11/30/08 None 0-ISIL4-101A-2.3 Complete in EOC23 11/30/08 None 49 OZ2L-7B 0-ISIL4-101A-2.3 Complete in EOC23 11/30/08 None O-ISIL4-102A-2.1 Complete in EOC23 11/30/08 None O-ISIL4-102A-2.2 Complete in EOC23 11/30/08 None 50 OZ2L-9 O-ISIL4-101A-2.3 Complete in EOC23 12/06/08 None O-ISIL4-102A-2.1 Complete in EOC23 12/06/08 None O-ISIL4-102A-2.2 Complete in EOC23 12/06/08 None Section 6 Prepared By: Date:

Section 6 Reviewed By: Date:

I67uUIwo{W-Refueling Outage Report EOC23 Page 4 of 4 Oconee Unit 2 Revision 0 Section 6 January 21, 2009