DAVE BAXTER Duke Vice President
- Energy, Oconee Nuclear Station Duke Energy ON0I VP / 7800 Rochester Highway Seneca, SC 29672 March 6, 2009 864-873-4460 864-873-4208 fax dabaxter@dukeenergy. corn U. S. Nuclear Regulatory Commission Washington, DC 20555-0001 Attention: Document Control Desk
Subject:
Duke Energy Carolinas, LLC Oconee Nuclear Station, Unit 2 Docket No. 50-270 2EOC23 Refueling Outage Steam Generator Inservice Inspection Report Per American Society of Mechanical Engineers (ASME) Boiler and Pressure Vessel Code, Section Xl, Subsubarticles IWA-6230 and IWA-6240, attached for your review is a summary report specific to the Steam Generator Tube Inservice Inspection activities conducted during Unit 2 EOC-23 Refueling Outage.
The Oconee Nuclear Station Technical Specification (TS) 5.5.10 establishes the Steam Generator (SG) tube surveillance program requirements for SGs. TS 5.6.8 requires the results of a SG Tube Inservice Inspection be reported to the NRC within 180 days following completion of the inspection.
Therefore, the results of the SG Tube Inservice Inspection performed during the Unit 2 End of Cycle 23 refueling outage are submitted at this time for your review.
Please address any questions to Corey A. Gray at (864) 873-6325.
Sincerely, Dave axter, Site Vice President, Oconee Nuclear Station Enclosures 4047~M www. duke-energy. corn
U. S. Nuclear Regulatory Commission March 6, 2009 Page 2 xc w/enclosures:
Luis Reyes Region II Administrator U.S. Nuclear Regulatory Commission Atlanta Federal Center 61 Forsyth St., SWW, Suite 23T85 Atlanta, Ga 30303 John Stang Project Manager U.S. Nuclear Regulatory Commission Office of Nuclear Reactor Regulation Washington, D.C 20555
- xc w/o enclosures:
Andy Hutto NRC Senior Resident Inspector Oconee Nuclear Station Susan Jenkins Section Manager Division of Waste Management Bureau of Land and Waste Management SC Dept. of Health & Environment Control 2600 Bull St.
Columbia SC 29201
I I
Steam Generator In-service Inspection Summary Report Oconee Nuclear Station Unit 2 EOC 23 Fall Outage 2008 Location: 7800 Rochester Highway, Seneca, South Carolina 29672 NRC Docket No. 5 0-270 National Board No. N/A Commercial Service Date: September 9, 1974 Owner: Duke Energy Carolinas, LLC 526 South Church St.
Charlotte, N.C. 28202 Revision 0 Prepared By:
Checked By:
Approved By:
"7 60 Date:
/
Date:
D ate:
Document Completion Date:
j /.Z" 9
.1
FORM NIS-1 OWNER'S DATA REPORT FOR INSERVICE INSPECTIONS As required by the Provisions of the ASME Code Rules
- 1.
Owner: Duke Energy Carolinas, LLC, 526 S. Church St. Charlotte, NC 28202 (Name and Address of Owner)
- 2.
Plant:
Oconee Nuclear Station, 7800 Rochester Highwav. Seneca, SC 29672 (Name and Address of Plant) 3.
4.
5.
6.
7.
Plant Unit:
2 Owner Certificate of Authorization (if required)
Commercial Service Date: September 9, 1974 National Board Number for Unit N/A Components Inspected:
N/A Component Steam Generator 2A Steam Generator 2B Manufacturer Babcock & Wilcox-Canada Babcock & Wilcox-Canada Manufacturer Serial No.
006K03 006K04 State or ProvinceNo.
N/A N/A National Board No.
207 208 Note:
Supplemental sheets in form of lists, sketches, or drawings may be used provided (1) size is 81/2 in.
x II in., (2) information in items I through 6 on this data report is included on each sheet, and (3) each sheet is numbered and the number of sheets is recorded at the top of this form.
FORM NIS-1 (Back)
- 8.
Examination Dates:
May 30, 2007 To December 12, 2008
- 9.
Inspection Period Identification:
- 10.
Inspection Interval Identification:
I1.
Applicable Edition of Section XI:
- 12.
Date/Revision of Inspection Plan:
Second Period Fourth Interval 1998 Addenda 2000 August 26, 2008 / revision 0
- 13.
Abstract of Examinations and Test. Reference attached response to technical specification 5.6.8, Steam Generator Tube Inspection Report.
- 14.
Abstract of Results of Examination and Tests. Reference attached response to technical specification 5.6.8, Steam Generator Tube Inspection Report.
- 15.
Abstract of Corrective Measures. Reference attached response to technical specification 5.6.8, Steam Generator Tube Inspection Report.
We certify that a) the statements made in this report are correct b) the examinations and tests meet the Inspection Plan as required by the ASME Code,Section XI, and c) corrective measures taken conform to the rules of the ASME Code,Section XI.
Certificate of Authorization No. (if applicable)
Date JZX
/*.
20 08 Signed N/A Duke Energy Carolinas, LLC I
Owner Expiration Date N/A 3y
/ /1; CERTIFICATE OF INSERVICE INSPECTION I, the undersigned, holding a valid commission issued by the National Board of Boiler and Pressure Vessel Inspectors and the State of Province of North Carolina employed by *The HSB CT., have inspected the components described in this Owner's Report during the period
- ee,,
to 4-,
_JAand state that to the best of mynowledge and belief, the Owner has performed examinations and tests and taken corrective measures described in the Owner's Report in accordance with the Inspection Plan and as required by the ASME Code, Section Xl.
By signing this certificate neither the Inspector nor his employer makes any warranty, expressed or implied, concerning the examinations, test, and corrective measures described in this Owner's Report. Furthermore, neither the Inspector nor his employer shall be liable in any manner for any personal injury or property damage or a loss of any kind arising from or connected with this inspection Commissions AI/CL /'/"-/-,
_C Inspector's Signature Date
/
7 200
- The Hartford Steam Boiler of Connecticut 200 Ashford Center North Suite 205 Atla National Board, State, Province, and Endorsements mnta, GA. 30338
Attachment to Form NIS-1 Oconee 2 EOC 23 Steam Generator Tube Inspection Report Pursuant to Oconee technical specification 5.6.8 the following information is provided:
- a. The scope of inspections performed on each SG The scope of the inspection performed on both 2A & 2B steam generators included 100%
of the active tubes in each Replacement Once Through Steam Generator (ROTSG) consisting of approximately 50% of the tubes each with the bobbin and x-probe. Special Interest (array) was also performed on selected indications.
- b. Active degradation mechanisms found Tube support plate wear was the only active degradation mechanism found.
- c.
Non-destructive examination techniques utilized for each degradation mechanism The Non-destructive examination techniques utilized bobbin coil for the detection of tube support plate wear. The array probe was utilized to characterize selected wear indications.
- d.
Location, orientation (if linear), and measured sizes (if available) of service induced indications The complete listing for service induced indications is attached.
- e.
Number of tubes plugged during the inspection outage for each active degradation mechanism Eight tubes were plugged in 2A ROTSG and twenty three tubes were plugged in 2B ROTSG, allfor tube support plate wear; no other tubes were plugged.
- f. The total number and percentage of tubes plugged to date There are fourteen tubes (0. 09 %) in the 2A ROTSG plugged to date and twenty-eight tubes (0.18%) plugged in 2B ROTSG.
- g.
The results of condition monitoring, including the results of tube pulls and in-situ pressure testing Condition Monitoring was demonstrated for both tapered and flat wear. An NDE maximum depth call of 73%TW or less for tapered wear is sufficient to demonstrate a minimum degraded tube burst pressure of 3AP, 4050 psi, at 0.95 probability with 50%
confidence. The worst case depth call observed during the Oconee 2EOC23 inspection was an NDE depth of 52% TW.
Flat wear occurs in the inspection port regions of both generators. The condition monitoring limit for flat wear was calculated as 54%. The maximum flat wear depth seen in either steam generator was 36 %TW in 2A ROTSG and 31% in 2B ROTSG.
No in situ pressure testing was required. No tube pulls were performed.
- h.
The effective plugging percentage for all plugging in each SG The effective plugging percentage is 0.09 % in the 2A ROTSG and 0. 18 % in the 2B ROTSG.
AREVA NP Inc Customer Name: ONS2 Repu 01/20/09 02:10:17 Component: S/G A Page 1 of 38 Service Induced Degradation QUERY: u2sg ROW COL 1
1 1
7 1
9 1
15 2
23 2
24 3
9 3
18 3
23 3
26 3
29 3
33 3
34 4
7 4
11 4
12 4
15 4
21 4
29 4
32 4
33 5
1 5
13 5
14 5
15 5
17 5
21 5
23 5
24 5
26 5
27 VOLTS 0.06 0.15 0.06 0.19 0.19 0.32 0.07 0.07 0.07 0.07 0.07 0.09 0.15 0.08 0.13 0.06 0.07 0.07 0.16 0.09 0.09 0.06 0.15 0.14 0.21 0.26 0.11 0.12 0.16 0.17 0.15 0.14 0.21 0.17 0.21 0.06 0.08 0.12 0.35 0.08 0.11 0.13 0.08 0.11 0.10 0.06 0.07 0.06 0.09 0.15 0.24 0.06 "0.20 0.10 0.25 0.13 0.08 0.06 0.08 0.08 0.17 0.33 0.82 0.07 0.14 0.08 0.07 0.10 0.21 0.10 0.17 0.46 1.14 0.07 1.20 3.74 0.06 0.08 0.12 DEG 140 140 124 139 133 138 145 93 ill 154 118 154 139 124 135 132 140 143 141 147 146 144 141 152 153 136 76 148 149 138 139 128 137 140 135 150 147 147 144 156 148 137 151 52 147 48 141 153 153 145 135 135 126 146 145 133 141 142 153 145 153 136 143 131 132 155 143 157 140 145 77 133 135 126 115 126 103 130 140 146 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2' P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 42 P2 P2 P2 P2 P2 P2 P2 P2 P2 22 P2 P2 166 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWE TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
ýTWD TWD TWD TWD TWD TWD TWD TWD TWDO TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD VOL TWD TWD TWD
%TW 5
10 5
14 13 18 6
6 6
5 6
7 10 5
10 5
6-6 11 7
7 5
10 9
14 17 9
9 11 12 11 10 15 13 13 5
6 9
19 5
8 10 6
9 7
7 5
6 4
7 11 16 5
14 8
17 10 6
5 6"
7 12 21 5
10 5
5 8
15 8
11 26 5
41 5
5 9
LOCATION EXT EXT 011
-0.26 LTE UTE 011
-0.29 LTE UTE 013
-0.31 LTE UTE 011
-0.29 LTE UTE 011
-0.26 LTE UTE 011
-0.23 LTE UTE 011
+0.36 LTE UTE 009
+0.67 LTE UTE 012
-0.31 LTE UTE 012
-0.39 LTE UTE 011
-0.28 LTE UTE 011
+0.36 LTE UTE 012
-0.39 LTE UTE 012
-0.36 LTE UTE 012
-0.34 LTE UTE 011
-0.29 LTE UTE 011
-0.31 LTE UTE 011
+0.39 LTE UTE 012
-0.42 LTE UTE 010
+0.49 LTE UTE 012
-0.39 LTE UTE 010
-0.49 LTE UTE 012
-0.42 LTE UTE 012
+0.44, LTE UTE 010
-0.46 LTE UTE 012
-0.39 LTE UTE 010
+0.73 LTE UTE 013
+0.34 LTE UTE 011
+0.34 LTE UTE 012
-0.39 LTE UTE 011
+0.37 LTE UTE 010
+0.42 LTE UTE 012
+0.37 LTE UTE 013
-0.39 LTE UTE 010
-0.44 LTE UTE 011
+0.37 LTE UTE 010
-0.54 LTE UTE 011
+0.31 LTE UTE 010
-0.44 LTE UTE 011
-0.36 LTE UTE 010
<-0.47 LTE UTE 011
-0.31 LTE UTE 010
-0.47 LTE.UTE 010
+0.65 LTE UTE 010
-0.44 LTE UTE 010
+0.70 LTE UTE 012
-0.42 LTE UTE 012
-0.39 LTE UTE 011
-0.26 LTE UTE 009
-0.31 LTE UTE 015
-0.34 LTE UTE 015
+0.62 LTE UTE 012
-0.34 LTE UTE 011
+0.37 LTE UTE 013
-0.37 LTE UTE Oil
+0.37 LTE UTE 012
-0.45 LTE UTE 011
+0.34 LTE UTE 011
+0.31 LTE UTE 011
-0.36 LTE-UTE 010
-0.49 LTE UTE 011
-0.36 LTE UTE 010
-0.47 LTE UTE 010
-0.49 010 010 011
-0.36 LTE UTE 012
-0.39 LTE UTE 009
-0.41 LTE UTE 011
-0.34 LTE UTE 010
-0.47 LTE UTE 012
-0.42 LTE UTE 010
+0.70 LTE UTE 010
-0.44 LTE UTE 010
-0.44 LTE UTE 010
-0.47 010 010 012
-0.47 LTE UTE 010
-0.42 LTE UTE 010
-0.47 010 010 011
-0.28 LTE UTE 011
-0.26 LTE UTE 013
-0.34 LTE UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 1
UTIL 2
CAL # LEG 8
6 3
30 30 30 32 4
8 30 0
30 32 30 3
30 32 32 30 8
4 8
5 8
5 6
7 8
0 30 0
30 32 32 30 30 8
3 8
0 8
9 6
8 8
8 8
32 3
30 30 30 32 32 4
30 30 4
30 7
30 30 7
30 5
30 30 32 8
8 0
8 8
8 3
8 8
8 0
8 4
8 3
6 8
6 30 29 0
32 30 32 2
32 30 30 8
30 32 30 29 32 LAR 32 31 30 32 4
30 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XP 510XB 510XB 510XB 28 30 32 36 41 1
6 12 14 16 18 19.
20 25 27 28 31 32 35 36 37 38 45 46 47
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:17 Component:
S/G A Page 2 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 7
15 0.09 7
17 0.08 7
18 0.11 0.12 7
19 0.14 7
20 0.29 0.06 7
26 0.06 7
27 0.20 0.15 7
31 0.12 7
33 0.07 7
35 0.05 7
37 0.52 1.25 7
38 0.09 7
39 0.26 0.13 0.06 7
40 0.09 7
42 0.11 0.22 0.10 7
47 0.32 7
48 0.06 7
51 0.13 7
52 0.09 8
2 0.15 8
4 0.21 8
9 0.15 8
11 0.19 8
12 0.11 8
17 0.09 8
18 0.07 8
21 1.21 0.21 0.33 8
23 0.09 8
28 0.11 0.11 8
35 0.22 8
38 0.07 8
40 6.12 0.09 8
41 0.22 0.42 1.24 8
42 0.25 8
43 0.06 0.22 0.06 8
44 0.08 0.10 8
45 0.29 0.12 8
55 0.14 9
17 0.11 0.07 9
18 0.25 0.18 9
19 0.16 9
20 0.10 9
22 0.15 0.12 9
23 0.13 0.15 9
26 0.06 9
29 0.10 9
39 0.09 9
43 0.21 9
44 0.09 0.11 0.08 9
48 0.07 0.07 0.12 9
50 0.10 0.07 0.07 9
57 0.11 DEG 132 145 139 116 142 142 115 158 141
'138 149 153 137 138 122 145 132 146 161 152 149 143 150 131 155 149 138 135 143 149 141 150 144 143 98 147 136 143 149 132 139 140 150 149 143 136 131 141 146 141 149 148 121 140 118 146 148 146 138 147 129 151 149 136 154 151 120 153 142 141 150 148 161 139 50 60 150 159 139 140 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 18 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P28 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 22 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW 7
7 8
9 10 18 4
5 12 10 8
5 4
26 7
16 9
4 7
9 15 7
18 5
9 7
10 14 11 13 8
7 5
15 21 7
8 8
16 5
8 6
15 24 15 5
15 5
5 7
19 9
10 9
5 16 12 12 7
11 9
10 11 4
8 6
13 7
8 6
6 5
9 8
6 6
7 LOCATION 012
-0.44 010
+0.44 010
-0.53 010
+0.47 010
+0.44 010
-0.49 011
-0.39 008
-0.45 011
-0.36 009
-0.41 012
-0.44 009
-0.44 011
-0.36 010
-0.44 010
-0.52 010
-0.49 012
-0.47 012
+0.36 010
-0.44' 014
+0.29 010
-0.44 012
-0.44 012
+0.31 012
-0.42 012
-0.44 012
-0.47 011
-0.28 013
-0.34 011
+0.42 012
-0.42 012
-0.45 013
+0.28 010
. +0.18 010
+0.39 011
-0.57 009
-0.47 011
-0.42 009
-0.44 012
-0.52 011
-0.42 012
-0.55 012
+0.31 010
-0.39 011
+0.34 010
-0.39 011
-0.36 011
-0.43 012
+0.34 009
-0.44 012
-0.47 012
+0.29 009
-0.41 012
-0.50 012
-0.47 012
+0.29 011
-0.28 014
-0.44 014
+0.26 013
-0.44 013
+0.23 010
+0.44 010
+0.42 010
-0.50 010
+0.16 012
-0.47 009
-0.44 008
-0.42 009
-0.44 008
+0.23 011
-0.37 011
+0.34 012
-0.47 011
-0.39 009
-0.44 009
+0.70 010
+0.65 012
-0.44 012
+0.39 011
.+0.36 012
-0.39 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 010 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 011 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 011 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE U¶E UTE UTE UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 011 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 011 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL 8
0 8
6 6
8 6
6 6
32 4
32 32 32 32 32 31 30 32 3
32 2
32 4
30 30 30
- 3.
30 32 30 32 30 6
2 6
8 8
6 8
6 7
8 8
0 8
6 2
6 74 5
32 32 4
32 30 30 29 32 30 5
30 0
30 32 32 30 6
30 30 0
8 0
8 6
6 0
8 6
6 6
8 0
8 6
0 8
6 32 32 30 30 30 4
30 5
30 9
30 30 30 0
30 32
- LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:17 Component:
S/G A Page 3 of 38 Service QUERY: u2sga.qry Induced Degradation ROW 9
10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 12 12 12 12 12 12 11 12 11 11 11 11 11 11 11 11 11 11 11 11 11 ii 11 11 11 11 11 12 12 12 12 12 12 12 12 COL 59 1
6 8
10 14 18 19 20 23 24 26 30 32 39 43 45 49 50 51 52 53 56 58 61 64 9
10 14 16 17 18 19 20 21 23 24 25 31 35 37 38 39 41 45 47 51 53 55 61 62 65 66 8
17 20 21 22 23 24 26 VOLTS 0.22 0.12 0.10 0.05 0.15 0.14 0.32 0.07 0.09 0.08 0.06 0.10 0.16 0.10 0.23 0.07 0.14 0.08 0.12 0.23 0.12 0.12 0.07 0.32 0.87 0.10 0.08 0.08 0.10 0.09 0.07 0.09 0.08 0.17 0.15 0.18 0.17 0.10 0.12 0.23 0.09 0.09 0.08 0.15 0.26 0.07 0.12 0.07 0.10 0.09 0.10 0.13 0.09 0.14 0.14 0.09 0.23 0.07 0.16 0.08 0.10 0.07 0.17 0.05 0.08 0.12 0.26 0.12 0.13 0.17 0.11 0.14 0.14 0.28 0.12 0.29 0.13 0.27 0.16 0.08 DEG 138 110 126 160 152 141 136 155 137 145 121 141 150 143 140 134 149 136 144 138 114 153 128 144 139 143 146 160 152 146 131 136 137 143 137 148 136 151 146 131 154 145 153 153 140 72 151 118 138 149 149 150 151 154 148 153 142 156 143 158 153 149 150 148 138 140 136 123 146 137 150 147 142 143 141 139 147 142 139 154 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 130 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 14 TWD 9 TWD 7 TWD 4 TWD 11 TWD 10 TWD 19 TWD 6 TWD 6 TWD 7 TWD 5 TWD 8 TWD 11 TWD 8 TWD 15 TWD 5 TWD 11 TWD 6 TWD 9 TWD 16 TWD 9 TWD 9 TWD 5 TWD 20 VOL TWD 7 TWD 6 TWD 5 TWD 7 TWD 7 TWD 5 TWD 7 TWD 6 TWD 12 TWD 11 TWD 12 TWD 13 TWD 7 TWD 9 TWD 15 TWD 6 TWD 6 TWD 5 TWD 9 TWD 15 TWD 6 TWD 9 TWD 6 TWD 7 TWD 7 TWD 7 TWD 10 TWD 7 TWD 10 TWD 11 TWD 7 TWD 16 TWD 6 TWD 12 TWD 6 TWD 7 TWD 5 TWD 11 TWD 3 TWD 5 TWD 9 TWD 17 TWD 9 TWD 10 TWD 13 TWD 9 TWD 10 TWD 10 TWD 17 TWD 9 TWD 19 TWD 10 TWD 18 TWD 12 TWD 6 LOCATION 011
-0.29 003
-0.23 011
-0.34 011
+0.34 012
-0.44 011
-0.39 012
-0.47 012
+0.29 010
+0.42 010
+0.50 010
+0.00 012
+0.18 009
-0.49 014
-0.49 011
-0.47 008
+0.26 012
+0.26 012
-0.55 012
-0.49 011
-0.36 011
+0.34 011
-0.39 009
-0.47 013
-0.44 013
-0.60 011
-0.34 012
-0.49 012
+0.31 010
-0.46 0il
+0.36 012
+0.36 013
-0.37 014
+0.29 0il
-0.37 012
+0.37 012
-0.47 012
+0.31 009
-0.50 011
+0.29 011
+0.26 011
-0.42 011
-0.42 011
-0.43 012
+0.28 012
+0.31 008
+0.26 01.l
-0.44 008
+0.23 008
+0.26 014
-0.54 012
-0.50 014
-0.52 011
-0.42 011
-0.42 011
-0.42 009
-0.44 011
-0.39 012
+0.34 012
-0.47 012
+0.31 013
-0.39 012
-0.44 012
-0.44 012
-0.41 011
-0.28 011
+0.37 011
-0.42 010
+0.65 011
-0.44 011
+0.26 012
-0.52 014
-0.49 014
+0.18 012
-0.55 011
-0.44 012
+0.24 011
-0.44 011
-0.47 011
+0.26 011
-0.44 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 013 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 013 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE uTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 1
oTIL 2
CAL # LEG 32 8
6 6
6 6
6 6
.2 6
0 8
6 0
8 6
6 6
6 30 6
30 30 30 30 30 32 30 29 0
32 4
30 0
32 32 30 4
32 6
8 0
8 0
8 5
6 8
5 6
5 8
6 4
6 6
76 76 76 6
30 30 32 30 30 30 0
30 30 30 30 30 5
30 30 30 32 32 32 32 32 0
12 10 8
8 8
8 8,
8 6
8 8
6 8
8 8
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET
.INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XE 510XB 510XB 510XB 510XB 510XP 510XB 510XE 510XE 510XB 510XB 510XE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XE 510XE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:17 Component: S/G A Page 4 of 38 Service QUERY: u2sga.qry Induced Degradation ROW COL VOLTS 12 44 0.12 0.24 12 54 0.11 0.08 0.13 12 55 0.09 12 56 0.26 12 57 0.21 0.06 12 60 0.07 12 61 0.07 0.08 12 62 0.10 12 66 0.07 13 3
0.15 13 7
0.22 13 10 0.18 13 16 0.23 0.20 13 18 0.29 13 20 0.09 13 28 0.12 13 30 0.10 0.28 13 50 0.05 13 60 0.32 0.17 0.13 0.90 13 62 0.12 13 65 0.10 13 68 0.10 0.20 13 69 0.23 14 2
0.11 14 11 0.22 14 13 0.17 14 14 0.08 14 17 0.08 14 19 0.10 14 27 0.06 14 54 0.12 14 60 0.12 0.12 14 62 0.16 14 64 0.11 14 65 0.13 14 67 0.14 0.21 0.05 14 68 0.15 15 9
0.10 0.12 0.19 0.18 15 11 0.08 0.16 15 17 0.22 15 19 0.14 15 38 0.14
.0.06 i5 44 0.09 15 66 0.16 15 67 0.12 15 70 0.07 15 73 0.11 15 74 0.09 15 78 0.10 16 1
0.15 16 4
0.12 0.13 16 9
0.12 16 10 0.13 16 11 1.31 0.09 0.37 16 13 0.14 16 14 0.13 16 50 0.23 16 62 0.06 DEG 152 140 148 136 138 153 136 141
.121 159 155 143 137 144 146 141 143 148 139 141 138 142 136 139 161 130 146 150 148 116 144 146 135 137 142 143 145 146 152 135 110 152 147 151 152 134 135 140 142 145 125 133 130 140 134 147 138
.140 145
.121 147 133 136 143 137 141 135 155 140 148 145 141 143 83 149 134 145 142 144 153 CHN IND P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD 118 VOL P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P4 VOL P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD
%TW 8
15 7
5 8
6 15 13 4
5 5
6 7
5 11 15 12 15 14.
18 6
9 7
18 4
21 13 10 9
8 8
15 15 9
14 12 7
6 7
5 10 10 10 12 9
9 10 14 4
12 8
9 13 13 6
12 15 11 10 4
7 12 10 6
8 7
8 11 9
10 9
9 7
22 11 9
17 5
LOCATION 011
-0.42 014
-0.54 009
-0.44 011
-0.39 014
-0.46 014
-0.44 012
-0.55 012
-0:47 005
+0.36 014
+0.23 014
-0.46 014
+0.26 012
-0.44 011
-0.31 013
-0.31 012
+0.34 012
+0.32 011
-0.42 Oil
+0.26 011
-0.44 011
+0.26 014
-0.54 011
+0.21 014
-0.52 011
-0.47 011
-0.34 011
+0.34 012
+0.36 011
-0.44 012
-0.47 012
-0.47 012
-0.44 013
-0.39 011
-0.29 011
-0.29 012
+0.26 011
-0.39 008
+0.29 009
-0.47 014
-0.49 008
+0.21 011
-0.44 012
-0.52 014
-0.46 010
-0.52 011
-0.34 010
-0.50 013
-0.39 014
-0.44 012
-0.45 014
-0.41 011
-0.37 011
+0.37 012
-0.42 012
+0.32 011
-0.34 011
+0.34 012
+0.24 011
-0.44 014
-0.62 014
-0.21 012
-0.55 009
-0.44 010
-0.49 013
-0.39 011
-0.31 011
-0.31 011
+0.42 009
-0.34 011
-0.31 011
+0.42 008
+0.26 011
-0.34 012
+0.08 009
-0.47 012
+0.24 011
+0.31 009
+0.57 011
-0.50 013
+0.21 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 011 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE' LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE EXT UTIL 1
UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 011 WAR 01E WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE
-WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 012 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTIL 2
CAL #
32 32 32 32 32 32 32 32
'32' 2
32 32 32 32 0
.32 20 12 10 10 10 10 10 10 10 10 34 34 34 34 33 74 0
36 34 34 36 20 10 10 12 10 6
10 10 34 0
34 0
34 34 74 7
36 36 36 0
34 0
12 12 12 12 12 12 12 12 10 10 34 5
34 0
34 0
34 44 4
42 42 20 18 5
18 10 10 11 12 12 0
12 10 34 0
34 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510 XE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB_
510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
.510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
.510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510 XE
AREVA NP Inc Customer Name: ONS2 Repr 01/20/09 02:10:17 Component: S/G A Page 5 of 38 Service Induced Degradation QUERY: u2sga.qry ROW 16 16 16 16 16 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 17 18 18 18 18 18 18 18 18 18 18 18 18 19 19 19 19 19 19 19 19 19 19 19 19 19 19 20 20 20 20 20 20 20 20 20 20 20 20 20 COL VOLTS 68 0.19 69 0.16 0.07 0.09 72 0.07 77 0.08 78 0.16 3
0.05 4
0.08 0.09 9
0.21 15 0.12 21 1.26 0.13 0.34 0.17 0.21 22 0.17 24 0.13 34 0.09 48 0.08 66 0.07 67 0.12 69 0.15 0.12 70 0.11 0.17 71 0.09 72 0.12 73 0.10 0.06 77 0.16 78 0.11 3
0.10 17 0.07 0.10 0.17 0.15 41 0.10 51 0.12 62 0.06 71 0.26 74 0.08 75
- 0. 8 78 0.07 79 0.09 81 0.16 84 0.19 1
0.11 3
0.07 0.11 4
0.10 7
0.13 0.11 0.16 16 6.08 43 0.07 65 0.07 72 0.06
- 73.
0.09 0.07 74 0.16 75 0.07 79 0.13 81 0.11 84 0.12 7
0.08 0.10 10 0.08 12 0.13 17 0.07 19 0.06 27 0.19 42 0.10 45 0.04 46 0.06 51 0.24 60 0.16 73 0.05 77 0.12 DEG 147 142 141 158 149 106 138 137 1il 156 135 146 88 155 138 131 139 129 139 156 146 142 123 142 148 146 133 145 149 147 44 138 147 146 153 97 146 131 151 150 108 141 119 150 157 150 138 139 144 135 154 145 145 152 137 143 145 157 150 133 143 147 131 147 140 139 149 145 145 139 149 160 142 131 81 102 129 138 158 140 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P3 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWDO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW 14 12 6
7 6
7 10 4
6 7
15 9
10.
21 12 15 11 9
7 6
5 10 12 10 8
12 8
9 9
5 11 9
7 6
8 12 11 8
10 5
19 6
7 5
7 12 12 8
6 8
7 10 9
12 6
5 5
5 6
5 13 5
9 7
9 6
8 6
10 6
5 14 7
4 5
17 11 4
10 LOCATION 009
-0.44 011
-0.37 012
+0.34 012
-0.52 013
+0.26 011
-0.34 012
-0.39 011
-0.29 011
-0.31 011
+0.39 011
-0.37 012
+0.26 011
+0.05 010
+0.65 011
+0.21 014
-0.55 014
+0.16 014
-0.54 014
-0.57 009
+0.18 011
-0.52 007
-0.38 014
-0.52 012
+0.31 009
-0.49 011
-0.36 012
+0.31 012
-0.49 012
+0.31 010
-0.49 009
+0.62 011
-0.34 011
-0.31 013
+0.34 009
-0.44 009
+0.63 014
-0.52 014
+0.19 011
-0.58 012.
+0.13 011
+0.23 011
-0.42 010
-0.54 014
+0.21 010
-0.49 010
-0.47 011
-0.31 011
-0.29 012
+0.39 011
-0.31 011
+0.39 011
.+0.36 012
-0.44 012
+0.34 013
+0.34 013
-+0.21 009
+0.18 011
+0.23 011
-0.42 013
-0.52 013
+/-0.18 010
-0.52 013
+0.21 010
-0.49 010
-0.44 011
-0.31 012
-0.44 013
-0.39 011
+0.34 011
-0.39 008
-0.44 008
-0.42 011
-0.55 014
+0.03 008
+0.16 008
+0.18 010
-0.58 014
+0.08 007
-0.44 012
-0.49 EXT EXT LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE
.LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL 1
UTIL 2
CAL WAR -----
34---
WAR 34 WAR 34 WAR 34 WAR 3
34 WAR 34 WAR 42 WAR 442 WAR 20 WAR 18 WAR 18 WAR 12 WAR 0
12 WAR 11 WAR 5
12 WAR 12 WAR 12 WAR 12 WAR 10 WAR 10 WAR 0
10 WAR 38 WAR 4
38 WAR 9
40 WAR 40 WAR 0
40 WAR 38 WAR 38 WAR 0
40 WAR 38 WAR 40 WAR 40 WAR 44 WAR 42 WAR 20 WAR 12 WAR 9
12 WAR 12 WAR 12 WAR 12 WAR 40 WAR 4
38 WAR 40 WAR 6
38 WAR 7
40 WAR 44 WAR 42 WAR 0
42 WAR 44 WAR 20 WAR 20 WAR 4
20 WAR 18 WAR 20 WAR 20 WAR 5
20 WAR 10 WAR 2
38 WAR 2
38 WAR 5
40 WAR 7
38 WAR 4
38 WAR 8
40 WAR 2
38 WAR 6
44 WAR 44 WAR 42 WAR 20 WAR 6
20 WAR 18 WAR 18 WAR 12 WAR 12 WAR 12 WAR 10 WAR 40 WAR 38 WAR 40 WAR 5
38 WAR 40 WAR 40
- LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB.
510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
- 510XB, 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Reol 01/20/09 02:10:17 Component:
S/G A Page 6 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.16 20 83 0.10 20 87 0.05 21 9
0.15 0.16 21 11 0.07 21 12 0.16 21 13 0.10 0.11 21 15 0.10 21 18 0.22 21 45 0.15 21 77 0.15 0.06 21 80 0.07 21 81 0.10 0.13 0.21 0.23 21 86 0.07 22 9
0.16 22 15 0.07 22" 28 0.07 22 37 0.09 22 75 0.12 22 81 0.11 22 82 0.14 0.06 22 85 0.10 22 86 0.08 23 23 0.26
,0.11 23 27 0.12 23 32 0.09 23 62 0.08 23 64 0.22 23 67 0.06 23 69 0.08 0.10 23 71 0.11 23 80 0.16 23 82 0.13 23 84 0.19 23
- 85.
0.24 23 89 0.06 24 5
0.10 24 11 0.11 24 20 0.09 24 21 0.12 0.10 24 33 0.23 24 60 0.27 0.27 24 72 0.10 24 81 0.11 24 87 0.08 0.08 24 89 0.08 24 94 0.08 25 3
0.20 25 63 0.02 25 77 0.13 25 83 0.09 25 93 0.07 26 9
0.16 26 12 0.09 0.16 26 14 0.15 26 15 0.14 26 24 0.07 26 45 0.14 26 65 0.27 0.17 26 66 0.05 26 75 0.27 26 92 0.13 26 97 0.07 0.05 26 99 0.07 27 1
0.08 DEG CHN 141 P2 141 P2 94 P2 146 P2 144 P2 160 P2 145 P2 151 P2 151 P2 141 P2 139 P2 130 P2 121 P2 140 P2 148 P2 146 P2 138 P2 138 P2 147 P2 141 P2 150 P2 145 P2 142 P2 156 P2 141 P2 144 P2 144 P2 156 P2 146 P2 147 P2 136 P2 144 P2 151 P2 117 P2 139 P2 126 P2 154 P2 134 P2 129 P2 106 P2 152. P2 148 P2 146 P2 142 P2 122 P2 133 P2 155 P2 144 P2 149 P2 140 P2 137 P2 143 P2 131 P2 140 P2 152 P2 144 P2 136 P2 154 P2 148 P2 130 P2 153 P2 81 P2 150 P2 157 P2 137 P2 142 P2 144 P2 140 P2 148 P2 150 P2 128 P2 132 P2 139 P2 135 P2 132 P2 125 P2 149 P2 165 P2 158 P2 139 P2 IND %TW TWD 13 TWD 8 TWD 4 TWD 11 TWD 11 TWD 6 TWD 11 TWD 8 TWD 9 TWD 7 TWD 15 TWD 11 TWD 11 TWD 5 TWD 6 TWD 7 TWD 9 TWD 13 TWD 14 TWD 6 TWD 12 TWD 6 TWD 6 TWD 8 TWD 10 TWD 9 TWD 10 TWD 4 TWD 8 TWD 6 TWD 18 TWD 9 TWD 10 TWD 7 TWD 7 TWD 17 TWD 5 TWD 6 TWD 7 TWD 8 TWD 12 TWD 10 TWD 14 TWD 15 TWD 4 TWD 7 TWD 8 TWD 8 TWD 9 TWD 7 TWD 15 TWD 19 TWD 19 TWD 8 TWD 9 TWD 6 TWD 6 TWD 7 TWD 6 TWD 14 TWD 2 TWD 11 TWD 6 TWD 5 TWD 11 TWD 7 TWD 11 TWD 11 TWD 10 TWD 6 TWD 10 TWD 17 TWD 12 TWD 4 TWD 17 TWD 9 TWD 6 TWD 4 TWD 6 TWD 6 LOCATION 010
-0.52 010
-0.49 002
-0.31 012
+0.34 012
-0.44 009
-0.44 013
-0.44 013
-0.44 014
-0.52 011
-0.42 014
-0.54 014
+0.05 012
-0.52 012
+0.29 011
+0.31 011
-0.36 011
+0.31 012
-0.47 013
-0.44 012
-0.42 014
-0.47 011
-0.39 011
-0.57 009
+0.16 013
-0.52 011
-0.39 011
-0.36 Qil
+0.31 012
-0.50 013
-0.42 014
-.0.57 014
+0.13 011
+0.18 011
-0.60 008
+0.16 010
-0.65 014
-0.03 011
-0.50 011
+0.21 014
-0.62 011
-0.42 011
-0.39 011
+0.31
.011
-0.39 010
-0.46 013
-0.42 012
-0.50 011
-0.50 011
+0.18 011
-0.52 011
-0.60 014.
+0.00 014
-0,.67 014
+0.08 011
-0.44 Oil
+0.31 012
+0.34 013
+0.23 012
-0.42 010
+0.76 008
+0.08 012
-0.62 007
-0.44 012
-0.47 012
+0.29 009
-0.47 012
-0.55 012
-0.52 011
+0.26 007
-0.41 008
-0.61 010
-0.71 014
-0.67 008
+0.16 010
-0.62 010
+0.65 011
-0.31 012
-0.44 012
-0.39 011
+0.31 EXT EXT UTIL 1
UTIL 2
LTE UTE WAR 9
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 6
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 5
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 5
LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR 3
LTE UTE WAR 6
LTE UTE WAR LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR 5
LTE UTE WAR 3
LTE UTE WAR LTE UTE WAR LTE UTE WAR 4
LTE UTE WAR 4
LTE UTE WAR 7
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 5
LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 6
LTE UTE WAR LTE UTE WAR 5
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 6
.LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 5
LTE UTE WAR LTE UTE WAR LTE UTE WAR 9
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR CAL # LEG 40 INLET 42 INLET 42 INLET 20 INLET 20 INLET 20 INLET 18 INLET 12 INLET 12 INLET 12 INLET 10 INLET 138 INLET 38 INLET 38 INLET 42 INLET 44
-INLET 44 INLET 44 INLET 44 INLET
-42 INLET 20 INLET 16 INLET 14 INLET 16 INLET 40 INLET 42 INLET 44 INLET 44 INLET 42 INLET 44 INLET 16 INLET 16 INLET 16 INLET 14 INLET 40 INLET 40 INLET 38 INLET 38 INLET 38 INLET 38 INLET 40 INLET 42 INLET 42 INLET 44 INLET 44 INLET 18 INLET 18 INLET 16 INLET 14 INLET 14 INLET 14 INLET 40 INLET 40 INLET 40 INLET 42 INLET 42 INLET 42 INLET 42 INLET 44 INLET 20 INLET 40 INLET 40 INLET 44 INLET 44 INLET 18 INLET 20 INLET 20 INLET 20 INLET 18 INLET 14 INLET 14 INLET 38 INLET 38 INLET 40 INLET 38 INLET 44 INLET 42 INLET 42 INLET 42 INLET 20 INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
.510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:17 Component: S/G A Page 7 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 27 3
0.13 27 4
0.13 27 23 0.06 0.07 27 27 0.10 27 28 0.06 27' 35 0.12 27 44 0.11 27 48 0:06 27 89 0.08 27 90 0.09 0.10 0.11 0.10 27 99 0.07 28 3
0.12 28 9
0.14 28 14 0.14 28 23 0.04' 28 26 0.11 0.11 28 45 0.15 28 48 0.06 28 50 0.10 28 90 0.06 28 91 0.21 28 93 0.11 28 94 0.09 28 97 0.07 28 101 0.07 29 1
0.05 29 10 0.16 0.16' 29 12 0M06 29 17 0.08 29 26 0.04 29 27 0.09 29 28 0.11 29 30 0.11 29 32 0.11 29 40 0.06 29 54 0.05 29 55 0.05 29
- 60.
0.06 29 81 0.11 29 96 0.12 29 100 0.09 29 104 0.07 30 1
0.06 0.13 30 3
0.11 30 26 0.09 30 44 0.12 30 49 0.05 30 53 0.04 30 60 0.05 30 67 0.05 30 96 0.09 31 1
0.43 0.19 0.13 0.13 1.88 31 6
0.13 0.09 31 10 0.07 31 20 0.05 31 26 0.13 31 27 0.13 31 41 0.12 31 56 0.03 31 80 0.18 0.07 31 95 0.10 31 96 0.10 31 98 0.29 0.14 0.24 0.14 31 99 0.13 DEG 146 143 153 150 145 151 133 136 136 141 136 139 146 134 157 149 146 148 141 118 149 144 128 153 35 149 144 152 145 142 152 144 134 153 146 94 143 138 127 149 77 139 138 148 141 143 146 119 56 142 153 137 147 135 77 148 126 150 129 i42 131 142 110 147 152 148 157 128 129 138 63 141 148 144 153 145 154 142 141 148 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 154 P2 P2 P2 P2 P2 P2 P2 P2
'P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW 10 10 4
5 7
5 8
8 5
7 7
7 7
6 9
11 10 4
8 8
11 5
6 4
15 9
6 6
6 4
11 11 5
6 4
6 8
7 7
5 4
5 5
9 8
6 6
5 10 9
7 7
4 4
5 4
25 13 10 10 9
7 6
4 9
9 7
3 13 5
7 8
19 11 17 11 9
LOCATION 011
-0.29 012
-0.39 011
-0.55 007
-0.54 011
-0.57 008
+0.18 011
-0.60 008
-0.64 008
-0.60 012
+0.31 012
-0.52 012
+0.34 014
+0.18 011
+0.31 012
-0.39 013
-0.34 011
-0.37 011
+0.29 008
-0.52 014
-0.67 014
+0.03 008
-0.65 008
+0.10 011
-0.69 009
+0.70 011
-0.42 012
-0.50 010'
+0.62 010
-0.44 005
-0.29 003
-0.26 011
-0.36 012
+0.29 009
-0.49 012
+0.18 008
+0.16 009
+0.13 011
-0.60 008
-0.54-008
-0.54 007
+0.16 007
+0.13 008
+0.13 008
+0.13 011
-0.52 012
-0.49 010
-0.44 004
-0.28 010
+0.73 011
-0.26 013
+0.34 011
-0.57 008
-0.54.
008
+0.13 008
+0.08 dio
+0.18 008
+0.13 013
-0.47 010
+0.71 011
+0.42 010
+0.39 010
-0.29 010
+0.52 011
+0.36 012
-0.39 011
-0.39 011
-0.52 011
-0.57 008
-0.57 008
-0.57 008
+0.05 011
-0.57 011
+0.10 012
+0.31 012
+0.29 011
-0.39 011
+0.34 013
+0.26 014.
-0.46 010
-0.46 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 010 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTIL UTE WAR UTE WAR UTE *WAR UTE WAR UTE WAR.
UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE' WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR' UTE WAR UTE
'WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR uTE WAR 010 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTIL 2
CAL # LEG 20 INLET 5
18 INLET 14 INLET 14 INLET 14 INLET 16 INLET 14 INLET 3
14 INLET 0
14 INLET 42 INLET 44 INLET 44 INLET 7
44 INLET 3
44 INLET 42 INLET 20 INLET 20 INLET 18 INLET 116 INLET 14 INLET 14 INLET 14 INLET 14 INLET 0
555 INLET 44 INLET 42 INLET 42 INLET 44 INLET 42 INLET 42 INLET 20 INLET 18 INLET 18 INLET 18 INLET 20 INLET 16 INLET 4
14 INLET 14 INLET 3
555 INLET 0
555 INLET 14 INLET 38 INLET 40 INLET 40 INLET 0
40 INLET 44 INLET
- 44.
INLET 42 INLET 20 INLET 20 INLET 2
20 INLET 3
14 INLET 2
555 INLET 14 INLET 40 INLET 40 INLET 40 INLET 44 INLET 20 INLET 20 INLET 7
20 INLET 8
20 INLET 19 INLET 3
18 INLET 4
18 INLET 18 INLET 18 INLET 0
14 INLET 14 INLET 4
555 INLET 40 INLET 38 INLET 3
38 INLET 44 INLET 42 INLET 42 INLET 42 INLET 42 INLET 42 INLET 44 INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:17 Component:
S/G A Page 8 of 38 Service QUERY: u2sga.qry Induced Degradation ROW COL VOLTS 0.07 32 5
0.14 32 9
0.13 32 10 0.13 32 25 0.10 32 33
.0.12 32 39 0.13 32 40 0.07 0.06 32 51 0.07 32 63 0.08 32 70 0.08 32 74 0.15 32 86 1.46 0.40 32 90 0.13 0.08 32 91 0.15 32 93 0.13 32 105 0.13 0.08 33 1
0.12 33 10 0.09 33 11 0.12 33 28 0.07 0.06 33 31 0.12 33 42 0.06 0.11 0.05 33 48 0.07 33 50 0.13 33 56 0.16 0.07 33 57 0.02 33 69 0.06 33 72 0.09 33 73 0.08 33 106 0.13 34 12 0.11 34 25 0.06 34 27 0.05 34 32 0.11 34 34 0.08 0.05 34 36 0.05 34 38
.0.07 34
- 49.
0.10 0.05 34 64 0.07 34 100 0.23 0.07 34 101 0.14 0.13 34 102 0.17 34 106 0.30 34 109 0.12 35 5
0.18 35
.6 0.20 35 26 0.05 35 27 0.11 35 29 0.11 35 34 0.07 0.09 35 38 0.08 0.08 35 40 0.10 0.06 35 46 0.12 0.06 35 49 0.13 0.09 35 51 0.06 35 53 0.05 35 65 0.06 35 79 0.15 0.10 0.11 35 95 0.08 0.08 DEG 150 142 142 142 144 134 142 149 100 69 147 146 130 119 125 139 135 148 132 154 156 142 149 150 135 153 138 143 114 82 82 144 147 79 148 148 149 144 147 151 145 102 142 148 114 118 77 96 149 152 123 158 148 150 143 142 145 126 147 112 130 127 129 149 154 116 130 115 132 108 138 129 139 126 157 138 136 153 149 140 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 70 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 5 TWD 10 TWD 9 TWD 10 TWD 8 TWD 7 TWD 8 TWD 5
'TWD 4 TWD 5 TWD 7 TWD 7 TWD 10 VOL TWD 25 TWD 9 TWD 6 TWD 12 TWD *10 TWD 10 TWD 6 TWD 9 TWD 7 TWD 9 TWD 5 TWD 5 TWD 9 TWD 5 TWD 8 TWD 4 TWD 5 TWD 9 TWD 11 TWD 5 TWD 2 TWD 5, TWD 6 TWD 7 TWD 9 TWD 8 TWD 5 TWD 4 TWD 8 TWD 6 TWD 4 TWD 4 TWD 6 TWD 7 TWD 4 TWD 6 TWD 14 TWD 5 TWD 11 TWD 10 TWD 11 TWD 18 TWD 9 TWD 13 TWD 13 TWD 4 TWD 8 TWD 7 TWD 5 TWD 6 TWD 6 TWD 6 TWD 7 TWD 5 TWD 8 TWD 5 TWD 9 TWD 7 TWD 5 TWD 4 TWD 5 TWD 12 TWD 8 TWD 9 TWD 5 TWD 6 LOCATION 010 010 012 009 010 008 012 008 008 011 008 007 008 014 014 012 012 011 012 011 012 009 011 012 008 008 008 007 008 008 007 007 007 008 008 008 007 014 011 012 008 008 008 00 08 008 008 007 008 008 008 012 012 011 011 011 012 008 010 013 008 008 010 008 009 009.
011 008 008 008 008 006 008 007 008 009 011 014 014 011 Ol
+0.62
+0.70
+0.26
-0.47
+0.16
-0.56
-0.77
-0.55
+0.16
-0.68
+0.10
-0.54
-0.61
-0.59
-0.64
-0.62
+0.26
-0.52
-0.57
+0.36
-0.42
+0.68
-0.42
+0.24
+0.16
-0.54
-0.57
-0.59
-0.60
+0.08
+0.08
+0.10
+0.13
+0.08
+0.03
+0.08
-0.54
-0.05
+0.36
+0.24
+0.16
+0.16
-0.55
-0.57
+0.13
+0.13
+0.-08
-0.65
+0.10
+0.03
-0.52
+0.34
-0.42
+0. 29'
-0.39
-0.41
-0.36
+0.68
-0.39
+0.18
-0.55
+0.08
+0.13
+0.08
+0.08
-0.65
-0.60
+0.08
-0.60
+0.10
+0.05
-0.62
+0.03
+0.60
+0.03
-0.60
-0.70
-0.05
-0.52
+0.16 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 014 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTILS WAR WAR WAR WAR WAR WAR.
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR
- WAR, WAR WAR WAR WAR WAR WAR 1
UTIL 2
CAL #
4 44 18 18 20 16 0
555 8
555 3
14 14 14 40 40 3
565 39 40 44 4
.44 4
42 42 42 42 20 18 20 14" 0
14 14 2
14 0
14 14 14 14 38 38 40 40 38 40 0
52 18 14 14 0
553 0
14 14 14 14 0
14 14 40 52 52 50 50 52 52 50 20 18 14 0
553 0
553 14 14 3
14 14 0
14 14 0
14 14-14.
0 14 42 2
42 40 40 40 6
40 52 52 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510UL 510UL 510XB 510XB 510XB 510XB 510XB 51OUL 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 5i0XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:17 Component:
S/G A Page 9 of 38 Service QUERY: u2sga.qjry Induced Degradation ROW COL VOLTS 35 102 0.11 35
- 104 1.32 0.13 0.15 0.33 35 107 0.07 0.08 36 5
0.07
-36 7
0.15 36 10 0.12 36 13 0.07 36 33 0.10 36 39 0.06 0.06 36 43 0.11 36 51 0.07 36 59 0.05 36 60 0.05 36 66 0.12 36 75 0.09 36 77 0.09 36 90 0.10 0.09 36 101 0.08 36 105 0.18 36 108 0.11 0.08
- 36.
109 0.23 0.16 36 113 0.21 0.06 37 4
0.11 37 12 0.16 37 13 0.13 37 14 0.09 37 26 0.08 37 39 0.12 0.08 37 46 0.13 37 49 0.07 37 50 0.09 37 52 0.06 37 77 0.17 37 89 0.06 37 103 0.11 37 106 0.14 0.11 37 108 0.13 37 110 0.10 0.08 37 11 0.09 37 113 0.09 37 114 0.08 38 1
0.14 0.06 38 4
0.31.
38 8
0.14 38 31 0.11 38 33 0.05 38 36 0.oii 38 38 0,08 38 39 0.14 38 41 0.08 38 53 0.11 0.04 38 54 0.06 38 55 0.11 0.04 38 68 0.08 38 87 0.08 38 94 0.06 38 106 0.22 0.21 38 107 0.05 38 112 0.15 38 114 0.12 0.07 38 115 0.06 39 1
0.07 0.08 DEG 152 105 147 146 137 148 142 129 144 138 129 132 71 115 155 152 54 122 141 117 144 134 141 141 152 150 144 138 148 145 155 149 147 137 149 128 78 83 130 143 108 133 148 142 150 139 142 129 138 152 152 141 136 150 117 137 147
.112 129 142 145 151 142 143 147 162 132 115 143 148 141 139 138 153 135 84 138 157 147 134 CHN IND P2 TWD 98 VOL P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD
%TW 9
10 11 21 5
6 5
11 8
5 8
4 5
8 6
4 5
10 6
6 7
6 7
13 8
6 16 12 15 5
7 11 10 7
6 9
6 9
6 7
5 13 5
9 10 7
9 7
6 7
7 7
10 5
18 10 8
4 8
6 10 6
8 3
5 8
3 7
7 4
14 13 4
10 8
5 5
5 6
LOCATION 012
+0.36 012
+0.26 011
-0.36 012
-0.47 012
+0.36 012
-0.44 011
+0.34 012
+0.36 013
-0.44 012
+0.26 008
+0.23 011
-0.63 008
+0.10 008
-0.57 007
+0.10 007
+0.03 007
+0.10 008
+0.03 007
-0.60 008
-0.61 007
-0.59 011
-0.54 012
-0.65 011
-0.44 011
-0.42 011
+0.36 013
+0.36 011
-0.36 011
+0.34 011
+0.41 013
+0.41 011
-0.31 011
-0.39 011
+0.29 012
+0.23 008
+0.13 008
-0.60 008
+0.10 008
-0.63 007
+0.13 008
-0.59 007
-0.59 007
-0.54 013
+0.05 011
-0.41 011
-0.39 013
+0.31 012
+0.39 011
-0.36 011
+0.36 011
-0.31 011
-0.28 012
-0.39 011
-0.26 003
-0.26 013
-0.39 013
-0.42 011
-0.62 008
+0.16 008
-0.60 007
+0.16 010
+0.05 007
-0.59 008
-0.59 008
+0.05 006
+0.13 008
-0.62 008
+0.03 007
+0.13 007
-0.54 012
+0.18 011
-0.44 012
+0.34 013
-0.44 011
-0.33 010
+0.72 008
-0.36 008
+0.36 013
-0.37 011
+0.37 EXT EXT UTIL LTE UTE WAR 012 '012 WAR LTE UTE WAR" LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR*
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE-WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR.
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 1
UTIL 2
CAL #
50 49 50 50 50 52 0
52 0
24 24 4
22 3
24 16 14 0
14 14 42 40 40 40 0
569 4
569 52 52 50 50 4
52 0
52 50 50 50 0
50 22 22 24 22 14 14 14
,14 14 42 42 40 40 50 52 0.
52 52 52 3
52 4
50 4
50 50 24 5
24 22 22 14 14 14 16 14 14 44 44 42 44 44 40 40 52 52 52 50 3
52 52 5
52 50 3
24 3
24 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET-INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET PROBE 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB' 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB*
510XB 510UL 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
.510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:17 Component: S/G A Page 10 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 39 3
0.05 39 12 0.15 0.11 39 14 0.09 39 17
'0.13 0.10 39 31 0.06 0.07 39 33 0.10 0.06 39 43 0.06 39 47 0.10
- 39 74 0.13 39 78 0.11 39 103 0.09 39 104 0.33 0.17 0.09 39-112 0.15 40 1
0.10 0.14 0.07 40 2
0.07 40 4
0.07 0.21 40 6
0.07 40 12 0.07 0.12 0.12 40 13
. 0.13 40 26 0.13 40 28 0.06 40 31 0.09 40 40 0.06 40 42 0.06 0.08 0.10 40 44 0.08 40 52 0.05 40 105 0.11 41 3
0.08 41 4
0.16 41 6
0.09 0.22 41 10 0.11 41 11 0.07 0.11 41 12 0.08 41 14 0.11 0.14 41 40' 0.05 41 42 0.12 41 50 0.14 41 61 0.06*
41 81 0.16 41 104 0.10 41 107 0.59 0.34 41 113 0.18 42 1
0.10 42 12 0.09 42 13 0.13 42 15 0.16 42 37 0.11 42 48 0.09 42 49 0.18 42 57 0.10 42 58 0.09 42 67 0.12 42 83 0.13 42 86 0.10 0.09 42 88 0.08 0.13 42 100 0.09 42 107 0.08 0.17 43 1
0.06 43 4
0.10 43 9
0.09 DEG 152 140 148 153 150 143 142 124 132 133 142 117 122 124 139 142 146 149 136 127 148 150 138 150 137 154 144 146 146 132 128 155 134 37 145 130 119 142 121 148 117 138 147 141 144 153 136 59 153 149 127 94 142 93 143 i52 121 137 152 148 140 150 144 140 115 148 30 134 122 131 146 145 122 124 148 155 147 158 152 144 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 86 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWD 4 TWD 10 TWD 8 TWD 7 TWD 10 TWD 7 TWD 5 TWD 6 TWD 7 TWD 5 TWD 5 TWD 7 TWD 9 TWD 7 TWD 7 TWD 19 TWD 11 TWD 7 TWD 10 TWD 8 TWD 10 TWD 6 TWD 5 TWD 6 TWD 14 TWD 6 TWD 5 TWD 9 TWD 9 TWD 9 TWD 9 TWD 5 TWD 7 TWD 5 TWD 5 TWD 6 TWD 8 TWD 6 TWD-4 TWD 8 TWD 6 TWD 11 TWD 6 TWD 14 TWD 7 TWD 5 TWD 8 TWD 6 TWD 8 TWD 10 TWD 4 TWD 8 TWD i1 TWD 5 TWD 13 TWD 7 VOL TWD 21 TWD 13 TWD 8 TWD 7 TWD 10 TWD 11 TWD 8 TWD 7 TWD 14 TWD 7 TWD 8 TWD 8 TWD 9 TWD 7 TWD 6 TWD 5 TWD 9 TWD 7 TWD 6 TWD 13 TWD 5 TWD 7 TWD 7 LOCATION 012
+0.39 012
-0.52 012
+0.23 010
+0.62 011
-0.47 011
+0.21 008
+0.10 011
-0.62 011
-0.65 009
+0.10 007
+0.05 008
-0.60 008
-0.62 008
-0.59 014
+0.16 013
-0.46 014
+0.21 013
+0.23 011
-0.33 003
-0.26 013
+0.31 012
-0.37 003
-0.28 011
-0.31 012'
+0.39 013
-0.47 009
-0.49 011
-0.39 012
-0.50 012
-0.55 014
-0.69 009
+0.08 008
+0.08 008
+0.08 007
-0.62 010
+0.00 011
-0.67 007
+0.10 008
+0.05 011
-0.47 011
+0.37 013
-0.39 012
-0.37 013
-0.42 012
+0.26 012
+0.23 012.
-0.58 012
-0.55 011
+0.26 011
-0.47 007
+0.10 008
-0.58 007
+0.03 007
+0.03 014
-0.75 012
+0.23 011
-0.52 011
-0.41 012
-0.44 011
-0.29 012
+0.21 011 70.42 013
-0.55 010
+0.03 008
-0.62 007
+0.10 007
+0.08 008
-0.62 008
-0.62 007
+0.10 010
-0.72 007
-0.59 008
+0.10 01i
-0.64 012
-0.62 009
-0.44 011
-0.44 011
-0.29 013
-0.39 011
-0.36 EXT EXT LTE OTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE' LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE.
LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE
,LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 011 011 LTE DTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL 1
UTIL 2
WAR 0
WAR WAR WAR 6
WAR WAR WAR WAR WAR WAR 3
WAR WAR WAR 0
WAR 0
WAR WAR WAR WAR 3
WAR WAR WAR 7
WAR 3
WAR 0
WAR 4
WAR WAR 0
WAR 6
WAR 4
WAR 7
WAR WAR WAR WAR WAR WAR WAR 4
WAR 8
WAR 4
WAR WAR 0
WAR 0
WAR WAR WAR WAR WAR 5
WAR 6
WAR WAR WAR 3
WAR WAR 0
WAR WAR WAR WAR WAR WAR WAR WAR 4
WAR WAR WAR WAR WAR WAR WAR WAR WAR 0
WAR 5
WAR 0
WAR 6
WAR 5
WAR 6
WAR WAR WAR WAR 4
WAR WAR CAL # LEG 24 22 22 22 24 24 14 14 14 14 14 14 569 569 50 52 52 52 52 24 24 24 24 24 24 24 24 24 24 22 22 14 14.
14 14 14 14 553 42 50 24 22 22 22 22 24 24 22 22 22 14 553 42 40 40 52 49 50 50 24 22 24 24 14 14 42 44 42 569 569 569 569 569 569 52 50 50 24 22 24 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXE' 510XE 510UL 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XE 510UL 510XBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXE 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB "510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510UL 510UL 510UL 510UL 510UL 510XB 510XB 510XB 510XB 510XE 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:18 Component: S/G A Page 11 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.15 43 28 0.14 43 38 0.07 43 50 0.05 0.06 43 87 0.15 43 89 0.13 43 98 0.08 43 105 0.10 43 106 0.20 43 112 0.10 0.08 43 115 0.15 44 1
0.07 44 3
0.14 0.13 44 4
0.10 44 7
0.13 0.-13 0.08 44 8
0.10 0.12 0.19 44 9
0.17 0.10 44 10 0.12 0.11 44 13 0.16 44 15 0.09 44 23 0.08 44 33 0.10 44 37 0.07 0.05 44 39 0.06 0.06 44 50 0.06 44 53 0.14 44 55 0.10 44 56 0.05 44 75 0.06 44 86 0.06 44 92 0.06 44 105 0.09 0.12 44 108 0.23 44 109 0.11 44 ill 0.09 44 113 0.46 0.22 0.30 44 117 0.11 44 119 0.10 0.07 45 1
0.10 45 3
0.10 45 9
0.14 0.08 45 11 0.09 45 31 0.06 45 74 0.05 45 82 0.13 45 84 0.04 45 93 0.10 45 107 0.13 0.09 0.13 45 109 0.08 45 110 0.13 0.07 45 111 0.12 45 112 0.13 45 113 0.25 0.09 45 116 0'.24 46 1
0.14
- 46.
4 0.20 0.16 46 7
0.12 46 31 0.06 46 32 0..15 DEG CHN 150 P2 125 P2 107 P2 148 P2 128 P2 143 P2 128 P2 156 P2 151 P2 144 P2 150 P2 158 P2 141 P2 143 P2 145 P2 145 P2 160 P2 148 P2 142 P2 148 P2 149 P2 148 P2 145 P2 147 P2 138 P2 153 P2 152 P2 144 P2 156 P2 148 P2 126 P2 128 P2 94 P2 70 P2 124 P2 77 P2 115 P2 79 P2 101 P2 133 P2 153 P2 149 P2 156 P2 142 P2 147 P2 150 P2 153 P2 115 62 142 P2 141 P2 144 P2 150 P2 135 P2 144 P2 148 P2 130 P2 130 P2 148 P2 106 P2 139 P2 132 P2 146 P2 130 P2 138 P2 149 P2 133 P2 153 P2 149 P2 158 P2 148 P2 140 P2 148 P2 135 P2 139 P2 145 P2 141 P2 131 P2 154 P2 93 P2 149 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW LOCATION 11 012
-0.58 10.011
-0.62 5
008
-0.59 4
007
+0.05 5
007
-0.62 10 011
-0.65 9
011
-0.62 5
012
+0.10 8
012
+0.21 13 011
-0.49 7
011
+0.28 6
013
+0.26 12 013
+0.31 5
011
-0.26 10 011
-0.29 9
012
-0.39 8
012
-0.45 9
012
-0.47 9
012
+0.31 6
013
+0.28 7
009
-0.44 8
012
-0.52 13 013
-0.47 11 012
-0.50 7
011
-0.36 9
011
-0.39 8
012
+0.23 11 013
-0.52 6
011
+0.21 6
010
+0.10 7
008
-0.62 6
008
-0.65 4
008
+0.05 5
008
+0.05 5
008
-0.62 5
007
+0.08 11 008
-0.64 7
008
-0.59 4
007
+0.08 5
008
+0.03 5
008
+0.08 5
0il
+0.03 7
012
+0.18 10 014 Z0.59 14 1l1
-0.46 9
011
-0.47 7
012
-0.49 012
-0.49 16 010
-0.44 20 012
-0.47 8
013
+0.33 8
013
+0.38 5
011
-0.31 7
013
-0.42 8
011
-0.29 10 012
-0.58 6-012
+0.26 7
012
+0.21 5
008
+0.08 4
008
+0.08 9
008
-0.60 4
008
+0.05 7
009
-0.64 10 011
-0.47 7
012
+0.13 10 012
-0.57 6
011
+0.26 9
011
-0.44 5
009
-0.62 9
012
-0.54 9
012
-0.52 17 012
-0.47 7
012
+0.34 15 012
-0.44 10 010
-0.29 13 011
-0.34 11 013
+0.28 9
012
-0.47 4
010
+0.08 11 014
-0.08 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT t:TE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL #
24 14 14 42 5
42 5
569 0
569 52 50 52 0
52 0
52 50
- 0.
24 22 22 24 22 22 22 24 24
.24 9
22 5
22 24 0
24 22 22 22 14 14 14 14 14 42 42 44 42 40 40 40 50 50 52 50 5
_50 49 50 50 136 50 2
50 4
24ý 24 6
24 6
24 3
24 14 40 0
573 40 5
569 50 50 6
50 2
50 52 52 50 5
52 50 3
50 52 24 24 0
24 3
22 14 14 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510 XB 510XB 510XB 510XB 510XB 51OUL 51OUL 510UX 510XB 510XB 510XB 510XB 510XB 510XB 510XB
.510XB
.510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XE 510XE 510XE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51 OXL 510XB 51OUL 510XB 510X 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXP 510XB 510OXE 510 XE
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:18 Component: S/G A Page 12 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.13 46 36 0.11 46 50 0.14 46 54 0.05 46 65 0:08 46 66 0.10 46 84 0.15 46 97 0.12 46 103 0.08 46 110 0.09 0.09 46 113 0.07 0.08 46 117 0109 0.10 47 1
0.10 47 3
0.08 47 5
0.09 47 57 0 09 47 63 0.08 47 76 0.06 47 109 0.09 0.08 47 110 0.08 47 111 0.i2 47 114 0.13 48 5
0.15 48 20 0.07 0.07 48 40 0.09 0.03 48 46 0.10 48 57 0.08 48 59 0.11 48 60 0.04 48 77 0.07 48 98 0.07 48 107 0.11 48 109 0.12 48 112 0.15 48 114 0.15 0.20 0.14 0.38 0.58 48 121 0.09 49 3
0.12 0.12 49 4
0.09 49 5
0.09 0.14 49 14 0.08 49 15 0.11 49 17 0.13 49 50 0.06 49 52 0.14 49 54 0.05 49 58 0.06 49
.59 0.06 49 62
- 0. 07 49 66 0.07 49 75 0.05 49 86 0.09 49 106 0.08 49 107 0.12 49 113 0.12 0.07 49 116 0.15 0.10 49 117 0.14 0.08 49 124 0.16 50 11 0.19 50 41 0.08 50 51 0.10 50 53 0.09 50 77 0.08 50 110 0.07 50 112 0.14 50 115 0.26 DEG 136 131 112 133 95 128 150 139 153 151 154 155 157 151 144 148 149 150 131 123 135
- 145, 139 153 158 139 154 119 151 119 96 103 115 124 55 114 154 139 139 133 133 148 146 136 106 152 123 110 141 141 152 150 159 148 121 136 143 77
.79 125 132 144 90 128 127 115 149 152 99 154 133 138 137
'115 45 121 116 143 138 148 CHN P2.
P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TW TWO 9
TWD 9 TWD 11 TWD Ii TWD 4 TWD 7 TWD 7 TWD 12 TWD 10 TWD 6 TWD 7 TWD 7 TWD 5 TWD 5 TWD 6 TWD 7 TWO 8 TWD 6 TWD 7 TWD 7 TWD'6 TWD 5 TWD 7 TWD 6 TWD.6 TWD 9 TWD 9 TWO 10 TWD 5 TWD 5 TWD 7 TWD 3 TWD 7.
TWD 6 TWD 8 TWD 3 TWD 5 TWD 6 TWD 9 TWD 9 TWD 10 TWD 10 TWD 13 TWD 9 TWDO 21 VOL TWD 7 TWD 8 TWD 8 TWD 7 TWD 6 TWD 9 TWD 6 TWD 8 TWD 9 TWD 4 TWD 10 TWD 4 TWD 5 TWD 5 TWD 5 TWD 5 TWD 4 TWD 6 TWD 6 TWD 9 TWD 9 TWD 6 TWD 10 TWD 7 TWD 11 TWD 6 TWD 11 TWD 13 TWD 6 TWD 7 TWD 8 TWD 5 TWD 5 TWD 9 TWD 18 LOCATION 014
-0.79 011
-0.66 008
-0.62 007
+0.03 008
-0.60 008
-0.60 007
-0.62 013
-0.68 012
+0.10 011
-0.47 011
+0.23 014
+0.23 013
+0.28 013
-0.39 013
+0.31 013
-0.39 012
-0.39 013
+0.23 008
-0.62 007
+0.13 007
+0.08
.008
-0.54 011
-0.46 011
+0.21 011
+0.26 013
+0.25 012
-0.42 008
-0.57 010
+0.10-008
-0.65 008
+0.03 008
-0.62 007
+0.08 008
-0.62 007
+0.10 007
+0.08 014
+0.00 011
-0.52 011
-0.49 012
-0.54 012
-0.52 013
-0.47 013
+0.26 014
-0.51 014
-0.54 013
-0.36 011
-0.31 010
+0.70 013
-0.39 010
-0.36 012
-0.42 011
+0;24 011
-0.47 011
-0.54 008
+0.,05 007
+0.08 008
+0.00 008
+0.05 007
+0.03 007
-0.65 007
+0.13 006
+0.16 008
-0.62 012
+0.15 011
-0.54.
012
-0.57 011
-0.46 011
-0.44 012
-0.49 012
-0.49 013
+0.26 013
+0.38 011
-0.42 010
-0.68 008
-0.60 007
-0.62 008
-0.65 011
+0.21 012
+0.21 013
+0.28 EXT EXT LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 014 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL # LEG PROBE 14 74 42 42 5
40 0
577 40 50 0
52 5
50 2
50 52 0
52 3
52 5
52 24 0
24 0
24 5
603 6
603' 136 5
50 4
50 3
52 4
50 52 22 24 24 0
14 14 3
549.
136 136 138
.0 577 50 50 5
50 52.
52 52 52 52 51 4
50 22 22 24 22 6
22 0
24 0
22 0
22 76 136 136 136 138 3
603 136 136 0
577 52 50 50 5
50' 52 52 50 0
50 68 24 6
549 5
76 0
599 0
577 52 52 50 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET iNLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 51OUL 510UL 510XB 510XB 510XB
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:10:18 Component: S/G A Page 13 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.11 50 116 0.13 0.35 0.67 50 121 0.06 51 1
0.09 51 2
0.07 51 7
0.35 1.18 51 10 0.09 51 57 0.11 51 61 0.14 51 62 0.15 51 114 0.15 51 119 0.11 52 43 0.10 52 57 0.09 52 58 0.11 52 59 0.08 52 60 0.09 52 63 0.07 52 67 0.06 52 69 0.07 52 75 0.04 52 76 0.06 52 77 0.11 52 90 0.05 0.12 52 92 0.04 52 112 0.06 0.15 0.08 52 113. 0.13 52 116 0.11 52 118 0.16 0.08 53 7
0.12 53 10 0.16 0.11 53 39 0.11 53 45 0.07 53 61 0.05 53 73 0.05 53 77 0.11 53 89 0.09 53 109 0.13 53 116 0.08 53 118 0.15 53 119 0.21 53 120 0.21 54 1
0.06 54 3
0.14 54 28 0.09 54 29 0.11 54 34 0.08 54 47 0.09 54 52 0.14 54 54 0.12 54 60 0.07 54 70 0.10 54 71 0.06 54 110 0.14 54 115 0.09 54 120 0.13 0.23 54 121 0.11 54 125 0.10 55 3
0.11 0.06 55 4
0.09 55 8
0.22 0.16 0.10 55 54 0.07 55 57 0.07 55 62 0.09 55 67 0.05 55 71 0.07 55 73 0.09 55 75 0.05 DEG CHN 145 P2 150 P2 140 P2 67 Q1 157 P2 146 P2 153 P2 142 P2 130 82 148 P2 102 P2 97 P2 143 P2 135 P2 149 P2 134 P2 112 P2 137 P2 75 P2 157 P2 62 P2 100 P2 132 P2 130 P2 135 P2 134 P2 112 P2 129 P2 141 P2 159 P2 127 P2 147 P2 137 P2 146 P2 149 P2 143 P2 142 P2 146 P2 146 P2 141 P2 141 P2 45 P2 131 P2 114 P2 104 P2 136 P2 143 P2 141 P2 143 P2 146 P2 153 P2 74 P2 143 P2 122 P2 111 P2 137 P2 142 P2 136 P2 73 P2 124 P2 129 P2 139 P2 159 P2 148 P2 138 P2 145 P2 153 P2 148 P2 159 P2 135 P2 139 P2 129 P2 148 P2 95 P2 118 P2 141 P2
.41 P2 130 P2 138 P2 103 P2 IND TWD TWD TWD VOL TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW LOCATION 8
014
+0.23 9
011
-0.44 20 012
-0.51 012
-0.57 5
012
-0.36 7
012
+0.31 5
011
-0.31 20 013
-0.42 013
-0.52 7
011
-0.42 8
008
-0.62 10 008
-0.62 11 007
-0.57 12 014
-0.54 7
012
-0.46 7
008
-0.60 8
007
-0.65 8
008
-0.62 6
007
+0.13 7
011
-0.75 5
007
+0.08 5
007
+0.10 6
007
+0.10 3
007
+0.03 5
067
+0.08 8
007
-0.65 4
008
+0.10 10 068
-0.60 4
008
+0.08 5
012
+0.18 11 012
-0.60 6
011
-0.49 9
010
-0.46 9
012
+0.23 12 012
-0.49 6
013
+0.28 8
012
-0.47 11 013
-0.44 7
013
+0.23 8
010
-0.73 5
008
-0.62 4
007
+0.08 4
007
+0.03 8
007
-0.64 6
007
-0.59 9
012
-0.67 6
008
-0.51 11 012
-0.49 13 013
+0.28 15 012
-0.46 5
013
+0.36 9
010
+0.72 6
010
+0.08 8
008
-0.59 5
008
-0.59 6
011
-0.77 10 011
-0.73 9
007
-0.62 5
007
+0.08.
7
.007
+0.05 5
007
+0.03 9
011
-0.56 7
012
+0.18 9
011
-0.41 14 013
+0.20 8
010
+0.21 7
013
+0.33 8
013
+0.31 4
010
-0.36 7
013
+0:29 14 011
-0.36 11 012
-0.47
- 7.
012
+0.29 6
007
-0.65 6
008
+0.05 9
007
-0.60 4
007
+0.13 5
007
+0.10 7
007
+0.08 4
007
+0.03 EXT EXT UTIL LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 013 013 WAR LTE.UTE WAR LTE UTE-WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR' LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR
'LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR I UTIL 2
CAL #
6 50 52 52 51
.4 50 0
72 0
24 22 21 7
24 0
597 0
597 136 8
50 0
52 6
549 5
599 0
597 0
136 0
597 136 136 136 136 136 0
577 40 4
40 40 50 6
50 4
50 52 50 50 50 5
24 3
22 0
22 5
549 0
549 136 136 0
577 0
577 7
60 58 58 60 58 72 70 22 0
543 76 76 6
549 136 136 136
.138 60 58 60 0
60 0
58 68 4
24 0
24 5
22 22 22 22 136 136 0
.599 136 136 136 136 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XP 510XB 510UL 510UL 510XB 510XB 510XB 51OUL 51OUL 51OUL 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 51OUL 510XB 510XB 51OUL 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:18 Component: S/G A Page 14 of 38 Service QUERY: u2sga.qry ROW COL VOLTS DEG 0.05 98 55 111 0.27 138 0.09 90 55 117 0.21 151 0.07 149 0.20 142 55 119 0.19 149 0.20 146 55 120 0.13 143 55 121 0.15 150 55 124 0.11 151 55 125 0.26 142 55 126 0.07 145 56 3
0.10 137 56 5
0.08 44 56 8
0.15.
137 56 31 0.07 138 56 54 0.06 108 56 58 0.09 145 56 111 0.14 136 56 120 0.60 131 0.17 144 1.04 104 56 123 0.07 143 56 124 0.15 151 0.13 141 57 2
0.18 142 57 3
0.11 143 57 4
0.16
'146 0.13 72 57 6
0.09 123
.57 9
0.07 156 57 26 0.11 151 57 48 0.09 92 57 49 0.08 153 57 54 0.08 120 0.09 124 0.09 140 57 55 0.08 122 57 67 0.10 145 57 72 0.04 145 57 73 0.09 117 57 75 0.04 129 57 78 0.06 145 57 111 0.16 136 57 114 0.05 147 57 115 0.08 140 57 117 0.19 143 57 118 0.33 137 57 119 0.17 133 57 120' 0.14 144 0.16 136 0.12 151 57 123 0.13 146 57 125 0.08 153 58 2
0.10 150 58 3
0.08 147 0.13 139 58 6
0.11 143 58 8
0.09 123 0.11 147 58 9
0.16 131 58 10 0.05 145 0.14 151 58 16 0.06 152 58 66 0.05 82 58 77 0.06 147 58 79 0.11 117 58 106 0.11 123 58 115 0.08 142 58 117 0.10 122 58 120 0.07 143 0.12 153 58 121 0.14 143 58 122 0.13.
143 58 123 0.09 130 0.13 155 58 128 0.11 83 59 3
0.11 106 59 4
0.26 145 Induced Degradation CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 26 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO
%TW LOCATION 4
'008 17 011 7
012 15 013 6
014 14 012 14 011 14 012 9
011 11 012 8
012
- 16 012 5
012 7
010 6
010 10 011 5
008 5
007 7'
008 10 011 28 012 11 013 012 5
014 11 012 10 012 14 012 7
010 11 010 9
010 7
011 5
009 8
007 6
008 5
006 6
005 7
007 7
007 7
007 9
007 3
006 8
007 3
007 4
007 12 011 4
011 7
008 14 011 19 012 12 012 9
012 11 012 8
011 10 013 6
012 7
013 5
009 9
010 8
011 7
009 8
012 11 012 4
009 10 011 5
011 4
008 5
007 8
007 8
011 6
012 7
012 6
012 9
011 9
012 10 012 6
010 9
.012 8
010 9
010 17 013
+ 0.03
-0.54
-0.62
+0.26
+0.23
-0.57
-0.41
-0.49
-0.44
-0.46
-0.44
-0.44
-0.41
-0.33
+0.68
+0.31
+0.03
-0.65
-0.62
-0.54
-0.51
+0.28
-0.54
-0.41
-0.49
+0.31
-0.39
-0.33
-0.34
+0.68
-0.36
-0.44
-0.56
-0.60
+0.10
+0.18
-0.62
+0.03
-0.63
-0.57
+0.13
-0.65
+0.08
+0.08
-0.57
+0.18
+0.18
-0.46
-0.54
-0.54
-0.54
+0.23
-0.44
+0.26
-0.41
-0.31
-0.36
-0.33
-0.34
-0.42
+0.31
+0.26
-0.47
+0.29
+0.21
+0.08
+0.05
-0.03
-0.60
+0.13
-0.57
+0.26
-0.44
+0.15
-0.52
+0.13
-0.49
+0.72
-0.36
+0.28 EXT LTE ITE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTEý LTE LTE LTE ITE LTE LTE ITE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE
- LTE LTE LTE LTE LTE LTE LTE EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE:
UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR
- WAR, WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL # LEG PROBE 136 136 136 58 3
58 6
58 58.
7 58 60 58 66 68 68 5
70 6
28 22 22 136 136 0
58 60 60 59 0
58 66 66 72 5
70 28 7
28 3
28 26 5
543 76 76 136 136 5
136 0
599 0
599 136 3
599 136 136 58 60 58 58.
60 136 60 60 60 58 66 70 3
70 4
70 4
.26 26 26 28 26 0
26 0
.26 136 136 136 58 60 60 58 4
58 60 58 0
60 4
60 68 0
'72 28 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510UL 510UL 510XB 510UL 510XB 510XB 510XB 510XB 510XB 5.10XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:18 Component:
S/G A Page 15 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.12 59 6
0.19 59 86 0.06 59 104 0.12 59 121 0.07 60 2
0.13 0.13 60 3
0.25 0.09 60 4
0.72 0.34 0.26 0.35 0.12 60 42 0.07 60 55 0.10 60 73 0.09 60 111 0.16 60 120 0.15 60 122 0.23 0.08 60 123 0.34 60 124 0.17 60 126 0.13 0.11 60 128 0.24 60 129 0.07 61 1
0.10 61 2
0.26 61 3
0.17.
0.15 61 4
0.93.
0.37 0.11 61 6
0.11 61 13 0.07 61 52 0.06 61 53 0.12 61 101 0.09 61 11 0.11 61 118 0.07 61 121 0.14 61 123 0.20 0.11 61 124 0.09.
61 125 0.07 62 1
0.08 62 2
0.23 0.10 62 3
0.34 0.20 0.08 1.25 62 4
0.13 0.22 0.12 62 8
0.11 62 31 0.04 62 32 0.05 62 41 0.08 62 108 0.07 62 118 0.12 62 123 0.23 62 124 0.08 62 127 0.18 63 1
0.20 63 2
0.38 0.17 0.11 1.22 63 3
0;37 0.09 1.25 63 4
0.91
- " 0.38 0.12 0.19 63 5
0.13 63 7
0.16 63 8
0.10 DEG CHN 147 P2 146 P2 129 P2 101 P2 143 P2 143 P2 121 P2 137 P2 144 P2 116 2 138 P2 135 P2 138 P2 151 P2 145 P2 135 P2 116 P2 130 P2 150 P2 148 P2 152 P2 137 P2 142 P2 149 P2 142 P2 146 P2 142 P2 140 P2 147 P2 143 P2 109 P2 127 94 144 P2 128 P2 149 P2 92 P2 153 P2 119 P2 152 P2 142 P2 155 P2 152 P2 139 P2 154 P2 154 P2 157 P2 142 P2 139 P2 132 P2 135 P2 142 P2-154 P2 118 50 151 P2 148 P2 146 P2 156 P2 153 P2 129 P2 118 P2 147 P2 111 P2 141 P2 154 P2 154 P2 139 P2 139 P2 107 P2 138 P2 118 50 139 P2 142 P2 118 50 120 38 140 P2 131 P2 145 P2 142 P2 149 P2 150 P2 IND %TW TWD 12 TWD 13 TWD 5 TWD 9 TWD 5 TWD 10 TWD 10 TWD 18 TWD 7 VOL TWD 19 TWD 16 TWD 20 TWD 8 TWD 5 TWD 7 TWD 7 TWD 11 TWD 11 TWD 15 TWD 6 TWD 19 TWD 13 TWD 9 TWD 8 TWD 15 TWD 5 TWD 8 TWD 18 TWD 13 TWD 12 VOL TWD 20 TWD 7 TWD 8 TWD 6 TWD 4 TWD 8 TWD 7 TWD 8 TWD 6 TWD 9 TWD 12 TWD 7 TWD 7 TWD 5 TWD 7 TWD 14 TWD 7 TWD 22 TWD 15 TWD 6 VOL TWD 9 TWD 13 TWD 8 TWD 8 TWD 3 TWD 4 TWD 6 TWD 5 TWD 9 TWD 14 TWD 6 TWD 13 TWD 15 TWD 23 TWD 12 TWD 8 VOL TWD 24 TWD 7 VOL VOL TWD 21 TWD 8 TWD 12 TWD 10 TWD 11 TWD 8 LOCATION 010
+0.60 011
-0.34 008
+0.13 011
-0.62 011
-0.44 010
-0.39 010
+0.72 010
-0.31 013
-0.36 013
-0.47 010
-0.33 011
+0.36 013
-0.36 012
-0.39 014
-0.15 007
+0.10 007
-0.62 011
-0.59 011
-0.46 011
-0.41 012
+0.26 012
-0.49 013
+0.31 012
+0.31 013
+0.31 013
+0.36 013
+0.38 009
-0.33 010
-0.28 010
-0.31 010
+0.72 010
-0.54 010
-0.33 011
-0.33 014
-0.44 009
-0.49 008
+0.03 008
-0.65 013
+0.03 011
-0.59, 011
+0.23 012
+0.26 012
-0.49 012
+0.31 013
+0.28 013
-0.41 010
-- 0.23 010
-0.33 010
+0.72 010
-0.31 010
+0.21 013
-0.36 010
-0.36 011
+0.36 010
-0.36 012
-0.41 014
-0.49 008
+0.11 008
+0.05 008
-0.70 014
-0.03 012
-0.59 012
-0.51 011
+0.28 013
+0.36 012
-0.36 010
-0.33 010
+0.71 010
+0.10 010
-0.31 010
-0.31 013
-0.39 010
-0.46 010
-0.44 010
-0.33 010
+0.26 012
-0.41 010
-0.36 014
+0.26 010
+0.65 EXT EXT LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 013 013 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 010 010 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE
.LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 010 010 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 010 010 LTE UTE LTE UTE 010 010 010 010 LTE UTE LTE'UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL #
10 28 28 136 58 0
58 72 72 72 72 69 70 70 70 0
70 76 136 0
597 60 4
136 136 0
136 60 58 68 68 68 68 72 72 7272 69 70 3
70 0
26 28 76 76 58 60 6
.58 60 60 60 3
58 0
58 0
72 70 70 72 5
72 0
72 71 70 0
70 4
7028 28 26 0
549 4
58 58 60 0
58 66 0
72 110 110 3
110 109 72 72 71 69 70.
0 70 7
70 6
28 28 26 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET" INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:18 Component: S/G A Page 16 of 38 Component: S/G A Page 16 of 38 Service QUERY: u2sga.qry Induced Degradation ROW COL VOLTS 63 11 0.07 63 14 0.14 63 15 0.09 63 55 0.06 63 56 0.06 63 74 0.13 63 117 0.08 63 119 0.15 63 121 0.07 63 122 0.14 0.28 0.12 63 123 0.08 63 124 0.19 63 125 0.14 0.12 0.07 63 126 0.09 63 130 0.07 0.22 64 1
0.37 1.41 64 2
0.46 0.14 1.58 64 3
0.16 0.13 0.13 64 4
0.29 64 5
0.25 0.13 0.13 0.18 64 6
0.12 0.09 64 7
0.10 64 10 0.14 64 14 0.08 64 31 0.06 64 38 0.06 64 52 0.07 64 71 0.08 64 79 0.05 64 113 0.16 64 118 0.18 64 119 0.06 64 124 0.27 64 125 0.10 0.15 0.39 0.06 2.05 64 126 0.08 0.15 64 128 1.09 0.16 0.40 65 1
0.16 65 3
0.10 0.29 65 4
1.16 0.52 65 5
0.25 65 6
0.09 65 7
0.28 65 9
0.13 65 10 0.15 65 16 0.13 65 37 0.06 65 39 0.04 65 47 0.05 65 55 0.11 65 74 0.12 65 87 0.05 65 114 0.15 65 119 0.28 0.17 65 122 0.16 0.06 65 123 0.26 DEG 147 152 147 137 126 124 156 126 151 151 135 135 151 145 145 149 160 153 147 139 139 105 137 139 115 143 72 150 146 147 118 149 151 151 152 39 148 151 139 99 107 128 137 136 150 148 137 150 149 145 151 123 148 143 102 141 140 140 144 142 115 138 144 94 142 151 155 144 59 133 141 136 118 142 131 134 144 153 154 141 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 58 P2 P2 50 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 42 P2P2 74 P2 P2 P2 P2P2 38 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD VOL TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW LOCATION 6
009
-0.49 10 011
-0.47 7
012
+0.16 4
008
+0.05 5
008
-0.03 10 007
-0.64 6
012
+0.18 11 012
-0.57 6
011
+0.26 10 011
-0.46 17 012
+0.23 8
012
-0.57 7
012
+0.28 12 012
-0.51 11 012
-0.52 10 013
-0.36 6
012
+0.31 7
012
+0.31 5
012
-0.39 14 013
+0.38 23 012
+0.42 012
+0.31 27 010
-0.28 11 011
-0.31 010
-0.39 11 010
-0.33 8
010
+0.69 8
012
-0.41 19 010
-0.33 15 010
-0.36 8
010
+0.72 8
012
-0.44 12 012
+0.33 9
012
-0.42 7
011
+0.34 7
010
+0.69 10 010
+0.68 6
012
+0.18 4
008
+0.13 5
008
+0.08 5
008
+0.03 7
007
-0.62 4
007
+0.10 12 012
-0.70 11 013
-0.52 5
007
-0.44 16- 012
-0.51 8
011
-0.41 12 012
-0.54 23 013
-0.39 5
007
'-0.36 013
-0.49 6
008
+0.31 11 0i3
-0.39 013
+0.13 12 012
-0.44 24 013
+0.33 12 011
-0.28 8
011
-0.31 19 012
+0.39 010
-0.46 26 010
-0.36 17 010
-0.36 7
010
+0.70 18 013
+0.28 10 012
-0.55 10 010
+0.65 9
008
+0.21 5
008
+0.08 3
008
+0.10 4
008
+0.08 10 007
-0.65 9
007
-0.62 4
007
+0.10 12 012
-0.67 17 012.
-0.59 11 013
+0.06 12 012
+0.26 5
008
-0.43 16 013
-0.41 EXT EXT UTIL LTE UTE WAR LTE DTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR 010 010 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 013 013 WAR LTE UTE WAR LTE UTE WAR
.013 013 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 010 010 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE.UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 1
UTIL 2
CAL #
28 4
26 3
28 136 136 3
597 3
58 58 58-4 60 60 4
60 58 5
60 58 58 3
58 66 68 68 72 71 72 7
72 71 70 70 1
70 72 70 70 70 70 7
26 O
26 28 26 26 26 4
2 0
599 136 58 60 4
58 0
60 58 58 58 4
58 57 66 66 65 66 66 72 72 72 69 70 28 26 28 3
28 26 26 4
4 4
0
.599 0
597 136 58 60 60 58 3
58 4
60 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET
.INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXB 510XP 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510UL 510XB 510XB 510XB 510XB 510XE 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:18 Component: S/G A Page 17 of 38 Service QUERY: u2sga.qry Induced Degradation ROW COL VOLTS 65 128 0.17 66 3
0.09 0.20 66 4
0.09 66 5
0.12 66 6
0.28 0.17 0.15 66 7
0.18 66 10 0.08 66 13 0.22 0.09 66 53 0.05 66 55 0.04 66 116 0.08 66-119 0.09 0.11 0.10 66 120
'0.06 66 123 0.11 0.26 0.24 66 124 0.17 66 131 0.28 0.08 0.08 67 1
0.12 67 2
0.14 0.08 67 4
0.10 67 6
0.18 67 7
0.17 67 11 0.12 67 13 0.07 67 18 0.09 67 19 0.03 67 52 0.05 67 110 0.10 67 113 0.05 67 117 0.06 0.10 67 120 0.18 67 122 0.15 0.14 67 123 0.21.'
67 125 0.12 67 126 0.19 68 1
0.14 0.09 68 2
0.19 68 4
0.06 68 7
0.64 1.55 68 9
0.10 68 10 0.20 0.14 68 11 0.15 68 21 0.04 68 122 0.15 0.17.
68 129 0.11 68 131 0.18 69 1
0.08 0.07 69 2
0.11 0.25 69 3
0.09 69 5
0.13 0.07 69 7
0.10 0.07 69 22 0.06 69 91 0.07 69 113 0.09 0.08 0.13 0.12 0.19 69 115 0.05 69 116 0.20 DEG 143 66 148 150 76 145 145 123 148 151 139 153 115 135 112 148 137 153 108 149 140 148 140 145 150 124 137 146 149 96 145 145 142 151 130 157 153 142 152 139 127 135 139 141 142 148 142 138 146 139 136 135 112 137 145 137 145 139 154 122 139 130 144 134 134 138 146 114 152 130 151 143 121 141 150 139 145 137 157
.142 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 154 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD tWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD.
TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW LOCATION 13 012
-0.41 6
010
+0.75 13 011
-0.28 8
011
+0.34 8
010
+0.67 18 010
-0.42 12 013
+0.28 10
.010
+0.70 13 010
-0.42 6
011
-0.42 15.014
-0.54 7
010
+0.55 4
010
-0.05 3
008
+0.10 6
012
-0.64 7
007
-0.44 9
012
-0.57 8
012
+0.16 4-007
-0.41 9
011
-0.44 18 012
-0.54 16 013
+0.28 11 013
+0.28 17 013
+0.43 6
011
+0.39 6
011
-0.26 10 010
-0.28 9
011
-0.28 5
013
+0.36 7
010
+0.69 12 010
-0.42 12 013
-0.42 9
012
+0.24 6
009
-0.52 7
010
-0.57 3
012
+0.14 4
006
+0.18 8
011
-0.62 3
008
+0.18 5
008
-0.49 8
011
-0.52 12 012
+0.18 10 012
+0.26 9
012
-0.54 15 012
-0.54 9
013
+0.31 14 012
-0.49 11 013
-0.29 8
011.
-0.28 14 011
-0.31 5
013
-0.39 31 010
-0.42 010
-0.50 7
010
-0.47 14 013
-0.47 10 013
+0.26 11 012
-0.52 3
012
+0.10 12 012
+0.26 13 012
-0.57.
7 013
-0.31 12 013
+0.41 7
002
+0.44 6
003
-0.26 9
003
-0.23 18 010
-0.28 6
011
-0.31 9
010
+0.70 5
012
+0.28 8
010
+0.68 6
012
+0.31 5
011
+0.08 5
007"
+0.13 7
012
-0.73 6
012
+0.08 10 013
-0.60 9
013
+0.13 14 014
-0.64 4
012
+0.13 13 012
-0.67 EXT EXT UTIL 1
UTIL 2
LTE UTEf WAR LTE UTE WAR LTE UTE WAR 5
LTE UTE WAR 0
LTE UTE WAR LTE UTE, WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 3
LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR LTE UTE WAR 3
LTE UTE WAR 2
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR LTE UTE WAR 5
LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR LTE UTE WAR 4
LTE UTE WAR LTE UTE WAR LTE UTE WAR 010 010 WAR LTE UTE WAR 3
ITE UTE WAR LTE UTE WAR LTE UTE WAR 5
LTE UTE WAR LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 3
LTE UTE WAR LTE UTE WAR 3
LTE UTE WAR LTE UTE WAR 4
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR CAL 66 70 70 72 70 26 26 26 28 26 28 28 4
4 60 58 58 58 60 58 58 58 60 68 68 68 72 70 70 70 26 28 28 28 26 26 2
58 60 58 58 60 60 60 58 58 66 72 72 72 72 26 25 26 28 28 26 26 58 58 68 68 72 72 72 72 70 70 70 26 26 26 136 58 58 58 58 58 58 60
- LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
'510XB "510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXN 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:18 Component:
S/G A Page 18 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.09 0.09 69 121 0.11 69 122 0.12 0.18 69 123 0.13 69 127 0.14 0.05 69 130 0.22 69 131 0.23 70 1
0.11 0.18 0.11 0.13 0.16 70 2
0.18 70 3
0.17 0.16 70 6
0.23 70 13 0.11 70 14 0.09 0.08 70 16 0.09 70 17 0.07 70 92 0.06 70 112 0.09 70 113 0.11 70 114 0.12 0.05 70 116 0.16 70 117 0.21 0.09 70 119 0.08 70 124 0.17 0.06 70 125 0.13 70 127 0.14 0.12 70 128 0.16 70 131 0.07 0.13 71 1
0.27 0.16 71 2
0.11 0.19 0.14 0.09 0.11 7i 3
0.13 0.11 0.19 71 4
0 11 0.09 71 5
0.18 71 7
0.09 71 10 0.12 71 11 0.07 71 30 0.07 71 58 0.08 71 65 0.07 71 123 0.10 71 125 0.15 71 128 0.14 71 129 0.05 71 130 0.08 71 132 0.16 0.i2 0.23 72 1
0.11 0.22 0.14 0.22 72 2
0.09 0.12 0.19 00O8 0.07 72 3
0.10 0.09 72 4
0.09 DEG 142 144 145 159 110 153 146 146 142 146 140 128 138 140 129 145 143 144 142 138 139 107 153 127 129 145 142 139 152 133 124 145 141 140 132 150 141 127 150 126 138 135 133 131 144 151 147 144 137 142 141 55 122 142 151 143 153 141 103 78 143 146 144 144 141 139 146 141 141 129 145 140 151 145 125 142 151 151 143 148 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2.
P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW LOCATION 6
012
+0.13 7
013
+0.13 9
013
+0.21 8
012
+0.18 11 012
-0.59 10 013
+0.26 10 012
-0.49 4
011
-0.36 14 013
-0.31 16 013
+0.41 9
001
+0.46 14 002
-0.23 9
002
+0.41 10 003
-0.23 12 003
+0.46 13 010
-0.28 11 011
-0.33 11 012
+0.36 16 013
+0.31 8
010
-0.52 7
006
-0.39 6
009
-0.52 7
009
-0.52 5
009
-0.55 4
007
+0.08 7
013
-0.65 9
014
-0.64 10 011
-0.59 4
011
+0.08 12 012
-0.67 13 012
-0.62 7
013
-0.52 6
007
-0.39 13 012
-0.52 5
007
-0.36 9
013
-0.39 9
013
+0.36 8
012
-0.49 12 012
-0.46 5,
003
-0.28 9
013
-0.26 19 002
-0.26 12 003
-0.23 9
001
+0.46 14 002
+0.41 11 004
+0.39 7
-005
+0.41 9
003
+0.46 8
002
-0.23 7
003
+0.46 12 011
-0.31 9
010 7 +0.67 8
012
+0.36 11 012
+0.28 7
012
-0.50 9
010
+0.65 5
009
-0.47 6
011
+0.03 6
008
-0.62 7
007
-0.55 7
012
+0.23 10 013
+0.26 10 012
+0.33 4
013
-0.34 6
013
-0.31 10 003
+0.41 8
011
+0.36 14 013
-0.23 9
001
-0.23 16 002
-0.23 11 004
+0.41 16 010
-0.26 7
001
+0.46 10 002
+0.33 14 003
-0.23 6
003
+0.13 6
005
+0.41 7
005
+0.38 6
011
+0.33 7
013
-0.36 EXT EXT UTIL 1
UTIL LTE UTE WAR LTE UTE WAR 4
LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR 6
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 5
LTE UTE WAR LTE UTE WAR 6
LTE UTE WAR LTE UTE WAR LTE*UTE WAR LTE UTE WAR S
LTE UTE WAR LTE UTE WAR 3
LTE UTE WAR LTE UTE WAR 4
LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 6
LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR 7
LTE UTE WAR LTE UTE WAR LTE UTE WAR 4
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 5
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR.
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 2
LTE UTE WAR 2
CAL # LEG 60-INLE-T--
60 INLET 60 INLET 58 INLET 60 INLET 60 INLET 58 INLET 66 INLET 66 INLET 68 INLET 66 INLET 72 INLET 72 INLET 72 INLET 72 INLET 72 INLET 72 INLET 70 INLET 70 INLET 26 INLET 26 INLET 28 INLET 28 INLET 28 INLET 26 INLET 136 INLET 583 INLET 58 INLET 58 INLET 58 INLET 58 INLET 60 INLET 60 INLET 60 INLET 58 INLET 58 INLET 60 INLET 68 INLET 68 INLET 66 INLET 68 INLET 68 INLET 72 INLET 72 INLET 72 INLET 72 INLET 72 INLET 72 INLET 72 INLET 70 INLET 70 INLET 70 INLET 72 INLET 72 INLET 70 INLET 26 INLET
- 28.
INLET 26 INLET 26 INLET 136 INLET 599
-INLET 60 INLET 60 INLET 68 INLET 66 INLET 68 INLET 68 INLET 68 INLET 68 INLET 72 INLET 72 INLET 72 INLET 72 INLET 72 INLET 72 INLET 72 INLET 72 INLET 72 INLET 70 INLET 70 INLET 72 INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB.
510XB 510XB 510XB 51OX B 510XB 510XB 510XB 510XB 510XB 510XB 510XB
- 510XB, 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 51OXE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXU 510XB 510UX 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510OXE 510OXE
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:18 Component: S/G A Page 19 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 72 5
0.21 72 6
0.18 0.13 72 7
0.20 72 8
0.08 0.15 0.13 72 11 0.12 72 13 0.20 72 18 0.06 72 24 0.07 72 30 0.06 72 55 0.08 72 72 0.11 72 109 0.10 72 116 0.06 72 117 0.29.
72 118 0.20 72 120 0.38 0.19 1.96 72 121 0.16 0.16 72 122 0.20 0.10 72 124 0.17 72 127 0.18 72 130 0.11 0.07 0.08 0.06 72 131 0.11 0.21 73 1
0.09
,0.60 0.22 0.14 0.09 0.13 0.23 0.05 0.25 0.18 2.07 73 2
0.14 0.24 0.48 0.14 0.09 0.27 0.10 0.22 1.33 73 3
0.13 0.22 0.23 73 5
0.27 0.10 73 6
0.14 0.07 73 7
0.31 73 9
0.22 0.21 73 10 0.15 0.19 73 11 0.17 73 14 0.21 73 18 0.08 73 24 0.09 73 36 0.06 73 66 0.15 73 73 0.08 73 102 0.09 73
-111 0.10 73 113 0.11 73 121 0.28 0.07 0.13 73 128 0.19 0.16 DEG 143 133 147 139 160 145 141 140 144 93 136 138 128 141 101 151 127 159 139 139 ill 137 137 135 145 136 150 135 146 159 158 129 132 137 132 138 139 141 143 133 141 134 145 107 142 144 132 134 149 140 144 141 120 141 143 1 4A 145 152 134 74 148 145 137 144 146 144 149 155' 143 118 139 103 153 128 108 143 157 143 145 146 CHN P 2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 106 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 134 P2 P2 P2 P2 P2 P2 P2 P2 22 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %TV TWD 13 TWD 12 TWD 9 TWD 14 TWD 6 TWD 11 TWD 9 TWD 9 TWD 13 TWD 4 TWD 5 TWD 4 TWD 6 TWD 8 TWD 8 TWD 5 TWD 17 TWD 14 TWD 23 TWD 14 VOL TWD 11 TWD 10.
TWD 14 TWD 8 TWD 12 TWD 12 TWD 9 TWD 6 TWD 6 TWD 5 TWD 8 TWD 13 TWD 8 TWD 32 TWD i6 TWD 11 TWD 8 TWD 10 TWD 17 TWD 5 TWD 18 TWD 13 VOL TWD 11 TWD 17 TWD 28 TWD 11 TWD 8 TWD 19 TWD 8 TWD 16 VOL TWD 9 TWD 13 TWD 14 TWD 16 TWD 7 TWD 10 TWD 5 TWD 19 TWD 14 TWD 14 TWD 11 TWD 13 TWD 12 TWD 15 TWD 6 TWD 7 TWD 4 TWD 11 TWD 6 TWD 7 TWD 8 TWD 8 TWD 19 TWD 5 TWD 10 TWD 12 TWD 10
= LOCI 013 010 013 013 010 012 013 012 014 009 009 008 008 007 Ol 013 008 012 012 012 012 012 012 012 012 012 013 003 006 012 013 003 013 001 o02 002 004 004 005 008 008 009 012 002 001 002 003 003 003 004 010 011 003 004 Ol 013 013 013 010 010 014 010 010 010 010 010 009 009 009 008 007 008 008 011 012 012 012 010 012 013
~TI10 N
-0.39
+0.65
+0.28
-0.39
-0.44
-0.52
+0.26
-0.55
-0.5.7
-0.57
-0.57
-0.59
-0.54
-0.62
-0.62
-0.57
+0.21
+0.16
+0.21
-0.60
+0.00
-0.57
+0.18
-0.57
+0.23
-0.52.
+0.33
+0.43
+0.38
-0.41
+0.36
-0.23
-0.28
-0.23
-0.23
+0.44
-0.26
+0.41
-0.26
-0.28
+0.39
+0.67
+0.39
-0.15
-0.21
-0.26
-0.23
+0.18
+0.49
+0.41
-0.31
-0.31
-0.44
+0.38
-0.33
+0.33
-0.39
+0.28
-0.42
+0.68
-0.47
-0.47
+0.65
-0.47
+0.62
-0.50
+0.57
-0.55
-0.57
-0.58
-0.59
-0.67
+0.73
-0.59
-0.68
-0.54
+0.21
+0.54
-0.46
+0.36 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 002 LTE LTE LTE LTE LTE LTE LTE LTE 003 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT DIE UTE UTE UTE UTE UTE DTE UTE UTE UTE UTE UTE UTE UTE UTE UTE DTE UTE UTE UTE UTE DIE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 002 UTE UTE UTE UTE UTE UTE UTE UTE 003 UTE UTE UTE UTE DTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTIL 1
UTIL 2
WAR WAR WAR 3
WAR WAR WAR WAR WAR 4
WAR WAR WAR WAR WAR WAR WAR WAR 0
WAR WAR WAR WAR 8
WAR WAR 6
WAR WAR 0
WAR 0
WAR WAR WAR WAR WAR 3
WAR 0
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 0
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 0
WAR 7
WAR WAR WAR WAR 0
WAR WAR CAL 70 28 28 26 28 28 28 26 26 28 26 26 2
136 58 58 60 58 58 58 57 60 60 58 58 58 68 66 66 66 66 68 68 72 72 72 72 72 72 72 72 72 72 71 72 72 72 72 72 72 72 72 71 70 70 70 70 70 28 28 26 26 26 28 28 26 28 28 26 2
136 136 583 583 58-58 58 58 68 68
- LEG PROBE INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XP INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XP INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XP INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 51OUL INLET 510UL INLET 510XB INLET 510XB INLET
- 510XB, INLET 510XB INLET 510XB INLET 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:18 Component: S/G A Page 20 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.12 73 131 0.16 0.07 0.05 0.08 0.17 73 132 0.20 0.16 0.10 0.13.
0.15 74 1
0.12 0.54 0.10 0.10 0.12 0.11 0.12 0.12 0.22 1.52 74 2
0.16 0.10 0.11 0.15 0.10 74 4
0.15 0.29 1.15 74 9
0.23 74 11 0.46 1.41 74 15 0.20 74 17 0.07 74 18 0.09 74 19 0.06 74 51 0.07 74 55 0.08 74 57 0.07 74 102 0.08 74 108 0.09 74 110 0.11 74 i11 0.10 0.11 74 113 0.12 74 115 0.06 0.10 74 117 0.22 74 119 0.08 74 130 0.09 0.14 0.17 0.13 0.10 0.14 0.12 0.10 0.17 74 131 1.49 0.17 0.10 0.18 0.10 0.14 0.51 75 1
0.49 0.14 0.13 0.10 0.10 0.09 0.29 0.11 0.27 0.98 0.60 75 2
0.18 0.11 0.14 0.18 DEG 141 139 155 141 128 143 126 145 130 138 137 148 133 136 149 139 124 141 141 145 109 137 137 145 140 145 147 144 110 147 141 125 135 132 92 105 85 109 115 152 150 125 130 145 115 155 139 139 141 135 152 133 119 153 122 145 139 147 109 136 146 141 142 132 133 136 132 141 130 132 139 133 141 146 104 129 144 150 150 144 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2
-P2 P2 134 P2 P2 P2 P2 P2 P2 P2 74 P2 P2 102 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 54 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 134 110 P2 P2 P2 P2 IND %TW TWD 8 TWD 12 TWD 6 TWD 4 TWD 6 TWD 13 TWD 13 TWD 11 TWD 7 TWD 9 TWD 10 TWD 10 TWD 30 TWD 8 TWD 8 TWD 10 TWD 9 TWD 10 TWD 10 TWD 16 VOL TWD 12 TWD 8 TWD 9 TWD 12 TWD 8 TWD 12 TWD 20 VOL TWD 15 TWD 25 VOL TWD 13 TWD 6 TWD 7 TWD 5 TWD 5 TWD 6 TWD 6 TWD 7 TWD 7 TWD 8 TWD 8 TWD 9 TWD 9 TWD 4 TWD 7 TWD 14 TWD 6 TWD 7 TWD 11 TWD 13 TWD 10 TWD 8 TWD 10 TWD 9 TWD 8 TWD 13 VOL TWD 11 TWD 7 TWD 12 TWD 7 TWD 9 TWD 26 TWD 28 TWD 11 TWD 10 TWD 8 TWD 8 TWD 7 TWD 20 TWD 9 TWD 19 VOL VOL TWD 13 TWD 9 TWD 11 TWD 14 LOCATION 012
+0.31 005
-0.25 012
-0.39 003
-0.20 004
+0.10 004
-0.33 003
-0.23 005
+0.41 004
-0.23 005
-0.25
- 010,
+0.71 001
-0.23 002
-0.23 002
+0.10 002
+0.44 003
-0.23 003
+0.44 004
+0.41 009
+0.65 010
-0.28 002
-0.28 003
-0.26 004
-0.28 005
+0.41 013
-0.36 010
-0.31 012
+0.36 013
+0.28 013
+0.23 013
-0.45 013
-0.50 013
-0.58 012
-0.57 009
+0.18 009
-0.57 009
+0.13 008
-0.64 007
-0.65 008
-0.62 012
+0.73 011
-0.62 012
-0.63 011
-0.62 012
+0.08 0il
-0.60 013
+0.10 013
-0.57 012
+0.13 008
+0.23 001
-0.23 003
-0.25 003
+0.43 004
-0.25 004
+0.38 005
-0.31 005
+0.36 007
-0.28 012
-0.38 011
-0.41 001
-0.23 001
+0.13 012
-0.38 006
+0.41 003
-0.20 011
-0.33 002
-0.23 002
+0.15 003
-0.23 004
+0.41 005
-0.26 005
+0.41 006
-0.28 006
+0.39 001
+0.00 002
-0.31 006
-0.31 001
-0.21 003
+0.44 004
-0.26 004
+0.41 EXT EXT LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE' UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 002 002 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 013 013 LTE UTE LTE UTE 013 013 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 011 011 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 002 002 006 006 LTE UTE LTE UTE LTE UTE LTE UTE UTIL 1
UTIL 2
WAR 6
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 0
WAR WAR WAR WAR WAR WAR WAR 7
WAR 0
WAR 4
WAR 0
WAR WAR 4
WAR WAR 3
WAR 5
WAR WAR 0
WAR 0
WAR WAR 3
WAR 4
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 6
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR CAL 68 66 66 66 66 66 68 68
.68 68 68 72 72 72 72 72 72 72 72 72 71 72 72 72 72 72 72 72 71 26 26 25 26 26 28 26 2
501 136 583 583 58 583 583 58 60 60 60 60 66 66 66 66 66 66 66 66 66 67 68 68 68 68 68 68 72 72 72 72 72 72 72 72 72 71 71 72 72 72 72
- LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 51OUL 51OUL 510XB 51OUL 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:19 Component: S/G A Page 21 of 38 Service QUERY: u2sga.qry ROW COL VOLTS DEG 0.15 148 75 3
0.24 145 0.17 146 0.16 140 0.09 142 0.08 150 0.08 155 0.18 143 75 4
0.15 141 0.10 144 75 5
0.08 155 0.09 157 75 6
0.14 144 75 7
0.07 126 0.09 141 75 8
0.18 142 75 9
0.16 149 75 10 0.10 154 75 11 0.11 149 0.11 146 75 53 0.09 134 75 59 0.14 137 0.17 128 75 64 0.09 97 75 79 0.10 123 75 112 0.14 145 75 117 0.06 90 75 118 0.07 149 75 119 0.08 147 75 126 0.23 140 75 129 0.13 153 75 131 0.57 114 0.15 145 0.12 149 0.19 143 0.09 144 0.06 153 0.18 144 0.17 151 0.28 141 0.32 136 0.13 138 75 132 1.06 i1 0.08 137 0.40 137 0.19 129 0.10 139 0.32 136 0.19 139 0.33 143 0.06 142 76 1
0.13 141 0.09 143 0.11 146 0.07 148 0.14 145 0.12 136 0.19 145 0.06 143 76 2
0.15 132 0.08 151 0.20 137 0.16 136 0.47 132 0.21 135 0.63 132 0.48 125 0.13 147 0.41 129 0.28 137 0.18 139 0.60 138 1.14 122 1.46 120 1.39 107 1.72 108 1.55 112 76 3
0.29 146 76 4
0.07 144 0.09 153 Induced Degradation CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 86 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 2
P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 110 110 26 106 90 P2 P2 P2 IND TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL VOL VOL VOL VOL TWD TWD TWD
%TW 12 15 11 11 6
6 5
12 12 8
6 6
10 5
7, 13 11 7
8 8
6 10 12 77 10 45 5
16 10 11 10 14 7
5 13 12 19 21 10 6
22 12 7
19 12 19 4
10 7
9 6
11 10 14 5
12 7
15 12 27 15 32 28 10.
25 19 13 32.
17 6
7 LOCATION 013
+0.36 002
-0.23 003
+0.43 008
-0.31 002
+0.41 008
+0.08 011
-0.33 012
+0.36 011
-0.34 012
+0.36 012
+0.31 011
+0.31 012
-0.47 010
-0.42 012
+0.31 013
-0.44 010
-0.44 010
-0.49 010
-0.50 012
-0.52 008
-0.65 007
-0.65 009
-0.70 008
-0.65 007
-0.64 014
+0.03 009
+0.10 008
+0.21 008
-0.54 012
-0.49 013
+0.36 003
+0.15 001
-0.23 001.
+0.15 004
-0.28 008
-0.35 008
+0.36 012
+0.36 013
+0.43.
005
-0.31 003
+0.00 005
+0.13 005
-0.
20 001
+0.13 005
-0.28 005
+/-0.13 006 70.05 011
-0.31 011
+0.38 003
+0.13 006
+0.40 001
-0.21 001
+0.49 002
-0:23 004
+0.41 011
-0.31 011
+0.39 012
+0.42 013
-0.29 001
-0.21 001
+0.49 002
-0.23 002
+0.00 002
+0.44 004
-0.03 004
+0.41
.005
-0.31 005
+0.41 006
-0.31 006
+0.36 013
-0.34 003
+0.13 006
-0.39 003
+0.00 002
+0.44 004
+0.28 005
-0.41 011
-0.33 005
+0.36 014
+0.26 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 003 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 005 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 006 003 002 004 005 LTE LTE LTE EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 003 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 005 UTE UTE UTE UTE.
UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 006 003 002 004 005 UTE UTE UTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL # LEG 72 70 70 70 5
70 4
70 4
70 3
70 72 0
72 70 3
70 28 0
26 0
26 28 26 28 26-3 26 6
501 136 136 136 136 58 60 58 60 58 66 65 66 66 66 66 66 66 66 66 13 66 66 67 68 68 68 68 68 68 68 68 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 72 71 71 71 71 71 70 72 72 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510 XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB' 510XB*
510XB 510XB 510XB 510XB
,510xB 510XB 510XB 510XB
-510XB 510XB 510XB 510XB S 510XB 510XB-510XB" 510XB 510XB 51OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XP 510XP 51OXP 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:19 Component: S/G A Page 22 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS DEG CHN 0.09 76 5
0.32 76 7
0.09 76 9
0.10 76 10 1.32 0.38 0.09 76 13 0.07 76 51 0.10 76 53 0.09 76 55 0.07 76 65 0.11 76 112 0.07 76 119 0.07 76 124 0.06 76 128 0.10 76 129 0.10 0.24 0.17 76 130 2.32 1.37 0.09 0.11 0.11
- 0. 30 0.29
,0-.09 0.78 76 131 2.51 1.68 1.28 0.30 0.08 0.50 0.17 0.18 0o08 0.46 77 1
0.59 0.27 0.07 0.19 0.12 0.11 0.13 0.22 0.20 0.23 0.14 1.99 77 2
0.18 0.23 0.22 0.08 0.14 77 3
0.13 0.26 77 4
0.06 0.13 0.20 0.08 0.11 77 7
0.05 77 9
0.08 77 10 0.15 77 13 0.09 0.07 77 62 0.12 77 96 0.06 77 115 0.22 77 116 0.10 77 118 0.13 77 120 0.16 77 125 0.10 77 130 0.11 0.09 77 131 1.84 0.16 0.42 0.11 119 P2 139 P2 158 P2 155 P2 132 166 147 P2 156 P2 145 P2 50 P2 140 P2 135 P2 94 P2 129 P2 150 P2 162 P2 148 P2 136 P2 139 P2
'148 P2 42 P5 38 P12 128 P2 149 P2 127 P2 138 P2 146 P2 134 P2 135 P2 97 P24 88 P15 96 P5 132 P2 139 P2 134 P2 133 P2 136 P2 137 P2 144 P2 130 P2 139 P2 145 P2 139 P2 143 P2 144 P2 142 P2 132 P2 145 P2 138 P2 138 P2 111 86 142 P2 134 P2 139 P2 143 P2 146 P2 136 P2 134 P2 141 P2 137 P2 144 P2 142 P2 136 P2.
148 P2 138 P2 152 P2 156 P2 153 P2 119 P2 62 P2 143 P2 151 P2 130 P2 140 P2 134 P2 141 P2 143 P2 43 P1 130 P2 137 P2 115 P2 IND TWO TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL VOL TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD
%TW 7
18 7
7 22 7
5 7
6 5
8 6
5 5
8 7
15 11 7
9 9
20 19 7
36 18 15 18 6
25 11 12 6
24 31 19 6
14 10 9
10 16 15 17 ii 14 17 16 6
11 9
15 5
10 157 9
4 6
11 7
6 9
5 16 7
9 11 9
7 6
12 258 LOCATION 011
+0.31 013
-0.39 013
+0.23 010
-0.49 010
-0.60 010
-0.47 012
-0.55 010
-0.57 007
-0.67 007
-0.67 007
-0.67 007
-0.62 015
+0.03 013
+0.18 013
+0.28 013
-0.31 004
-0.25 010
+0.66 013
+0.38 003
+0.00 004
-0.28 001
-0.23 002
-0.03 002
+0.36 004
-0.28 013
+0.38 005
+0.36 003
+0.15 008
+0.18 002
-0.35 002
-0.03 005
-0.25 005
+0.13 008
+0.36 010
+0.71 004
-0.15 007
-0.33 002
+0.05 002
-0.26 002
+0.46 004
-0.23 004
+0.44 005
-0.26 006
-0.31 010
-0.26 010
+0.75 011
+0.42 013
-0.31 013
+0.36 002
-0.26 001
+0.46 002
-0.23 003
-0.23 003
+0.44 010
-0:28 010
+0.69 011
-0.31 003
+0.18 010
+0.72 013
-0.34 001
+0.46 003
-0.26 012
+0.28 010
-0.49 010
-0.44 010
-0.49 012
+0.18 007
-0.65 007
+0.08 011
+0.13 011
+0.13 008
+0.23 012
+0.21 013
-0.42 006
-0.33 004
+0.38 005
-0.25 004
-0.25 005
-0.25 005
+0.13 EXT EXT LTE UTE LTE UTE LTE UTE LTE UTE 010 010 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 003 003 004 004 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 008 008 002 002 002 002 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 002 002 LTE UTE LTE UTE
ýLTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 005 005 LTE UTE LTE UTE LTE UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR.
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 1
UTIL 2
CAL # LEG 72 70 26 26 27 28 4
28 5
26 0
501 0
501 0
501 136 3
583 0
60 58 0
66 68 68 68 65 65 66 66 66 66 66' 66 66 67 67 67 68 68 68 68 68 68 68 72 72 72 72 72 72 72 72 72 72 72 71 72 72 72 72 6
72 70 70 72 72 0
72.
72 2
48 6
48 46 48 0
48 136 5
533' 130 2
128 128 128 130 68 4
68 65 66 66 66 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510UL 51OUL 510UL 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 51OXB 510XB 510XB 510XB 510XB 50XP 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:19 Component: S/G A Page 23 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.17 0.08 77 132 1.01 1.19 0.82 0.10 0.10 0.44 0.14 0.14 0.11 0.14 0.43 0.22 0.45 0.09 78 1
0.14 0.44 0.17 0.19 0.12 0.28 0.18 0.15 0.21 1.32 78 2
0.08 0.21 0.25 0.07 0.16 0.18 0.11 78 3
0.10 0.09 78 5
0.21 78 8
0.14 78 9
0.10 78 10 1.31 0.37 78 11 0.11 78 12 0.11 78 16 0.12 78 121 0.06 0.09 78 122 0.14 78 131 0.11 79 1
0.18 0.17 0.39 0.11 0.42 0.13 0.13 0.25 0.06 0.13 0.24 1.27 1.55 79 2
0.12 0.12 0.13 79 12 0.10 79
- 13.
0.08 79 14 0.14 79 15 0.09 79 75 0.08 79 108 0.13 79 120 0.16 0.10 79 122 0.16 0.12
.79 125 0.11 79 132 0.32 0.08 0.20 0.09 80 1
0.11 0.12 DEG 138 112 116 117 135 146 123 140 137 147 133 142 138 143 142 140 142 132 123 142 125 138 127 152 140 114 142 141 133 131 143 145 149 131 136 143 145 146 130 140 150 153 130 153 142 144 119 141 143 137 137 132 130 147 139 141 139 133 113 117 143 146 136 144 152 136 138 113 149 121 157 148 133 141 132 128 124 147 135 132 CHN P2 P2 2
2 158 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 86 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 10 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 6
14 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD VOL VOL VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD.
TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD VOL VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW 13 7
7 7
24 10 9
8 9
23 14 24 6
11 26 13 14 10 19 14 12 15 7
15 18 6
13 14 9
7 6
13 10 8
22 8
8 9
6 8
10 8
14 13 24 9
25 10 11 18 5
10 17 10 10 10 7
6 10 7
6 9
11 7
11 9
8 19 6
13 6
9 10 LOCATION 006
-0.28 005
+0.41 003
+0.08 005
-0.35 011
-0.30 001
-0.20 001
+0.20 005
-0.25 005
+0.13 006
+0.35 007
-0.28 008
-0.30 011
-0.30 011
+0.41 003
+0.20 006
-0.05 001
+0.46 002
-0.23 002
+0.18 002
+0.44 004
-0.26 004
+0.44 005
-6.28 005
+0.39 010
-0.26 002
-0.28 001
+0.03 001
+0.46 002
-0.23 003
-0.03 003
+0.41 004
+0.41 013
+0.33 002
-0.20 003
-0.23 013
-0.36 013
-0;42 012
+0.21 010
-0.70 010
-0.64 012
-0.54 013
-0.49 012
-0.57 013
-0.47 013
+0.21 013
+0.23 006
+0.38 001
-0.23 001
+0.49 002
-0.23 002
+0.15 003
-0.23 003
+0.18 003
+0.46 004
-0.26 004
+0.44 010
-0.28 010
+0.72 002
-0.39 003
-0.33 001
+0.46 003
+0.44 004
+0.41 012
-0.52 012
+0.18 010
-0.52 012
+0.13 007
-0.62 010
+0.08 012
-0.62 011
-0.49 012
+0.23 013
-0.47 012
+0.26 004
-0.25 005
+0.41 007
-0.30 011
+0.41.
002
-0.23 003
-0.23 EXT LTE LTE 003 005 011 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 002 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 010 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 002 003 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTE UTE 003+
005 011 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 002 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 002 003 UTE UTE UTE UTE UTE.
UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL #
66 66 67 67 67 68 68 68 68 68 68 68 68 68 68 0
68 72 72 72 72 72 72 72 72 72 71 72
- 72 72 72 72 72
.72 70 70 70 46 48 45 46 6
48 0
46 46 130 130 6
128 68 72 72 72 72 72 72 72 72 72 72 72 71 71 72 72 72 4
46 48 6
46 0
48 136 128 128 0
128 128 128 128 68 68 68 68 72 72 LEG TNLET.
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510OXB 510XB 510XP 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 5,10XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510OXB
AREVA NP Inc Customer Name: 0N52 Repi 01/20/09 02:10:19 Component: S/G A Page 24 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.08 0.15 0.09 80 3
0.14 80 4
0.09 80 5
0.25 80 8
0.15 80 10 0.09 80 86 0.09 80 114 0.07 80 117 0.09 80 118 0.18 0.22 80 121 0.15 80 129 0.23 81 1
0.07' 0.14 0.23 0.26 -
0.07 0.16 0.10 0.14 0.12 0.16 81 2
0.08 81 3
0.23 81 4
0.14 81 5
0.07 81 6
0.13 0.11 81 9
0.14 0.07 81 10 0.28 0.20 81 13
.0.11 81 117 0.12 81 123 0.06 81 124 0.08 0.15 81 126 0.11 0.06 81 130 0.17 81 132 0.25 0.13 0.07 0.15 0.13 0.09 0.14 0.10 82 1
0.27 0.08 0.05 82 2
0.21 82 3
0.23 82 5
0.15 82 6
0.21 82 9
0.15 82 10 0.14 0.10 82 115 0.13 82 117 0.10 82 119 0.09 82 120 0.20 0.21 82 126 0.18.
0.26 82 128 0.11 82 130 0.08 82 131 0.09 0.09
- 83 1
- 0.09 0.20 0.33 1.14 83 2
0.07 83 4
0.12 83 5
0.13 83 7
0.18 DEG CHN 135 P2 124 P2 134 P2 146 P2 142 P2 145 P2 141 P2 130 P2 142 P2 106 P2 125 P2 144 P2 128 P2 143 P2 141 P2 139 P2 137 P2 137 P2 138 P2 147 P2 141 P2 146 P2 141 P2 106 P2 135 P2 131 P2 143 P2 143 P2 153 P2 155 P2 155 P2 144 P2 154 P2 140 P2 144 P2 146 P2 148 P2 157 P2 149 P2 132 P2 146 P2 159 P2 141 P2 139 P2 142 P2 151 P2 146 P2 153 P2 147 P2 125 P2 122 P2 136 P2 151 P2 141 P2 137 P2 140 P2 151 P2 139 P2 147 P2 144 P2 144 P2 137 P2 136 P2 149 P2 148 P2 140 P2 146 P2 137 P2 137 P2 139 P2 136 P2 152 P2 142 P2 142 P2 135 P2 119 38 156 P2 146 P2 137 P2 145 P2 IND TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWO TWD TWO TWO TWD TWO TWO TWO TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWO TWD
,TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD
%TW LOCATION 7
004
+0.39 12 010
+0.73 8
004
-0.28 9
012
-0.41 7
012
+0.36 15 013
-0.39 10 013
-0.44 7
012
+0.23 6
008
-0.59 6
012
+0.10 8
012
-0.65 12 008
+0.21 14 011
-0.54 12 012
-0.52 14 013
+0.33 6
001
-0.21 11 001
+0.46 17 002
-0.23 18 003
-0.21 6
004
-0.03 12 004
+0.39 8
006
+0.36 11 010
-0.28 10 010
+0.75 12 013
-0.31 7
013
-0.34 14 011
-0.33 11 011
-0.34 5
-011
-0.33 9
012
+0.34 8
013
-0.42 11 010
-0.46 6
012
+0.21 17 013
-0.44 13 012
-0.52 8
010
-0.52 10 011
-0.52 6
013
-0.47 6
012
-0.54 10 013
+0.23 9
012
-0.49 6
012
+0.23 11 013
+0.36 15 005
-0.25 9
006
+0.38 5
008
-0.30 10 008
+0.38 9
011
+0.3,3 7
004
-0.28 9
005
+0.15 7
013
+0.41 19 011
-0.28 7
013
+0.36 4
002
-0.26 16 011
-0.28 14 011
-0.33 10 012
+0.28 14 013
-0.39 11 010
-0.44 10 012
+0.21 7
010
-0.47 10 011
-0.54 9
013
+0.15 7
011
-0.49 13 013
-0.52 14 013
+0.20 13 011
+0.31 18 012
+0.26 9
013
+0.33 6
0il
-0.31 6
011
-0.31 6
011
+0.39 7
010
-0.26 15 011
+0.39 22 013
-0.31 013
-0.39 6
008
+0.36 10 013
-0.36 8
010
-0.39 13 013
-0.39 EXT EXT UTIL LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE' WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE
-WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 013 013 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 1
UTIL 2
CAL #
72 72 6
72 4
70 0
72 70 46 46 4
535 6
130 130 128 128 130 68 72 72 72 72 72 72 72 72 72 72 72 5
70 72 5
70 46 0
46 48 0
48 46 0
46 48 130 130 128 0
128 6
130
'3.
130 68 68 68 68 68 68 0
68 7
.68 4
68 72 72.
72 72 70 70 0
46 48 46 4
46 128 5
130 130 128 128 66 66 4
66 66 68 3
68 72 72 72 71 0
72 72 70 48 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 51OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXBE.
510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:10:19 Component: S/G A Page 25 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 83 9
0.23 83 11 0.13 83 67 0.08 83 75 0.09 83 115 0.13 83 118 0.16 0.12 0.12 83 119 0.24 0.06 83 120 0.11 83 121 0.15 83 122 0.10
°0.18 83 128 0.09 83 129 0.06 83 132 0.09 0.24 0.09 84 1
0.12 84 2
0.23 84 6
0.12 0.27 84 7
0.12 84 55 0.10 84 107 0.09 84 121 0.11 84 122 0.20 84 125 0.08 84 128 0.17 84 130 0.21 0.10 85 1
0.10 85 6
0.20 85 10 0.09 85 74 0.08 85 114 0.13 0.14 85 115 0.20 0.13 85 119 0.12 85 121 0.11 85 122 0.18 85 124 0.11 0.07 85 125 0.15 85 126 0.10 85 128 0.13 0.14 86 1
0.07 0.11 86 4
0.27 86 6
0.06 86 7
0.08 86 11 0.11 86 58 0.06 86 116 0.20 0.10 86 119 0.18 86 121 1.75 0.75 0.22 86 122 0.10 0.17 86 127 0.18 86 128 0.07 0.05 86 131 0.07 0.10 0,.13 87 1
0.13 87 6
0.30 0.06 87 8
0.20 0.16 87 114 0.10 87 116 0.10 0.09 87 118 0.12 DEG CHN 138 P2 144 P2 117 P2 141 P2 139 P2 142 P2 154 P2 151 P2 141 P2 155 P2 150 P2 137 P2 127 P2 138 P2 146 P2 150 P2 137 P2 147 P2 153 P2 143 P2 139 P2 149 P2 142 P2 142 P2 129 P2 142 P2 151 P2 149 P2 150 P2 146 P2 149 P2 131 P2 146 P2 144 P2 147 P2 138 P2 142 P2 146 P2 139 P2 144 P2 138 P2 140 P2 148 P2 153 P2 154 P2 141 P2 135 P2 148 P2 145 P2 117 P2 138 P2 140 P2 149 P2 155 P2 151 P2 128 P2 146 P2 152 P2 143 P2 109 38 132 P2 143 P2 143 P2 149 P2 142 P2 157 P2 160 P2 95 P2 143 P2 153 P2 143 P2 138 P2 154 P2 137 P2 141 P2 142 P2 146 P2 143 P2 139 P2 138 P2 IND %TW TWD 16 TWD 10 TWD 6 TWD 7 TWD 11 TWD 11 TWD 8 TWD 8 TWD 17 TWD 6 TWD 8 TWD 12 TWD 7 TWD 12 TWD 7 TWD 5 TWD 6 TWD 15 TWD 6 TWD 10 TWD 17 TWD 8 TWD 17 TWD 9 TWD 7 TWD 7 TWD 9 TWD 13 TWD 7 TWD 12 TWD 15 TWD 8 TWD 8 TWD 14 TWD 7 TWD 6 TWD 10 TWD 12 TWD 13 TWD 9 TWD 9 TWD 8 TWD 14 TWD 9 TWD 6 TWD 11 TWD 8 TWD 10 TWD 11 TWD 6 TWD 9 TWD 19 TWD 5 TWD 7 TWD 8 TWD 5 TWD 14 TWD 7 TWD 12 VOL TWD 34 TWD 14 TWD 8 TWD 13 TWD 11 TWD 6 TWD 4 TWD 5 TWD 7.
TWD 8 TWD 10 TWD 19 TWD 5 TWD 8 TWD 14 TWD 12 TWD 8 TWD 8 TWD 7 TWD 9 LOCATION 010 012 007 007 OO7 008 008 011 013 012 013.
013 012 012 013 013 011 005 013 011 008 013 012 010 012 007 009 013 013 013 011 013 012 008 010 012 007 011 Oil 011 014 013 013 012 013 011 011 011 011 013 0i2 011 010 014 012 011 008 011 011 012 013 013 Oil 014.
013 014 013 011 006 004 007 008 011 013 013
-011 011 012 012 014 011 012
-0.44
+0.23
-0.64
-0.59
+0.18
+0.18
+0.16
+0.15
+0.16
+0.18
+0.18
+0.23
+0.21
+0.20
+0.33
+0.36
+0.40
+0.36
+0.39
+0.36
-0.34
-0.44
-0.39
+0.28
-0.67
+0.05
+0.21
+0.20
+0.28
+0.36
+0.38
+0.36
+0.34
-0.44
+0.21
-0.64
-0.57
+0.10
+0.13
+0.13
+0.18
+0.18
-0.54
+0.23
+0.26
+0.28
+0.28
+0.38
+0.33
-0.20
-0.28
-0.36
+0.24
+0.28
-0.44
+0.08
+0.15
-0.53
+0.18
+0.20
+0.20
-0.45
+0.21
-0.41
+0.31
+0.36
+0.36
-0.25
+0.38
+0.36
-0.28
-0.39
+0.26
-0.36
-0.44
+0.26
-0.67
+0.10
+0.18
+0.18 EXT EXT UTIL 1
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE-UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 013 013 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR tTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR UTIL 2
CAL #
48 48 144 144 130 128 128 3
128 130 130 0
128 130 128 128 0
68 66 68 68 0
68 72 72 6
46 0
46 48 5
501 4
537 130 128 130 74 74 0
74 72 48 48 0
591.
130 130 128 128 0
128 128 130
.4 130 0
130 128 0
74 74 74 72 72 72 46 48 4
48 144 128 128 128 127 128 128 130 130 76 74 74 76 76 76' 72 48 0
48 0
48 48 48 124 124 0
124 124 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET
.INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET' INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 51OUL 510XB 510XB 50XB
- 510XB, 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:19 Component:
S/G A Page 26 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 87 121 0.25 87 123 0.16 0.19 87 125 0.18 87 126 0.12 0.08 87 128 0.10 0.18 88 1
0.08 88 4
0.30; 88 6
0.10 88 80 0.13 88 116 '0.15 0.06 88 117 0.09 88 121 0.29 0.14 0.09 0.13 88 123 0.13 88 126 1.11 0.14 0.40 0.06 88 128 0.95 0.06 0.36 0.08
-88 131 0.12 0.06 0.06 89 4
0.15 89 8
0.12 89 14 0.15 89 122 0.10 89 123 0.25 0.06 89 124 0.25 0.32 0.11 89 125 0.17 89 126 0.12 0.10 0.12 89 127 0.34 89 128 0.11 90 2
0.08.
90 3
0.09 90 4
1.29 0.37 0.17 0.09 90 6
0.17 0.10 0.09 90 70 0.05 90 110 0.09 90 113 0.09 90 114
.0.09 0.13 90 119 0.21 0.21 0.27 90 122 1.10 0.30 90 123 1.93 0.42 0.12 90 124 1.36 0.06 0.08 0.60 90 127 0.07 0.11 90 128 0.07 0.20 0.31 90 129 0.11 91 1
0.25 91 11 0.13 DEG 137 146 141 136 152 147 150 145 148 143 131 ill 139 152 143 141 144 145 143 152 ill 130 140 158 106 156 137 146 153 43 158 146 141 147 136 145 157 142 142 144 144 144 147 149 140 144 149 146 117 138 148 138 142 149 154 77
-103 138 145 125 140 149 145 115 140 79 134 143 107 150 155 130 132 142 114 137 139 139 136 135 CHN IND %TW P2 TWD 17 P2 TWD 12 P2 TWD 14 P2 TWD 13 P2 TWD 9 P2 TWD 6 P2 TWD 8 P2 TWD 13 P2 TWD 6-P2 TWD 18 P2 TWD 7 P2 TWD 10 P2 TWD 11 P2 TWD 5 P2 TWD 8 P2 TWD 19 P2 TWD 10 P2 TWD 7 P2 TWD 10 P2 TWD 10 26 VOL P2 TWD 10 P2 TWD 24 P2 TWD 5 26 VOL P2 TWD 5 P2 TWD 23 P2 TWD 6 P2 TWD 8 P2 TWD 4 P2 TWD 4 P2 TWD 10 P2 TWD 9 P2 TWD 11 P2 TWD 7 P2 TWD 17 P2 TWD 5 P2 TWD 16 P2 TWD 19 P2 TWD 8 P2 TWD 13 P2 TWD 9 P2 TWD 8 P2 TWD 9 P2 TWD 18 P2 TWD 9 P2 TWD 5 P2 TWD 8 62 VOL P2 TWD 20 P2 TWD 11 P2 TWD 6 P2 TWD 12 P2 TWD 7 P2 TwO 6 P2 TWD 4 P2 TWD 7 P2 TWD 7 P2 TWD 7 P2 TWD 10 P2 TWD 14 P2 TWD 14 P2 TWD 17 98 VOL P2 TWD 20 P28 VOL P2 TWD 24 P2 TWD 9 134 VOL P2 TWD 5 P2 TWD 6 P2 TWD 31 P2 TWD 6 P2 TWD 9 P2 TWD 5 P2 TWD 12 P2 TWD 17 P2 TWD 7 P2 TWD 18 P2 TWD 9 LOCATION 013
-0.49 012
+0.26 013
+0.23 012
-0.49 013
+0.30 011
+0.26 011
+0.36 012
+0.31 013
+0.36 010
-0.33 012
+0.31 007
-0.64 014
-0.62 014
+0.10 012
+0.18 013
+0.21 014
-0.52 014
+0.18 013
-- 0.50 012
-0.36 013
+0.05 012
-0.49 013
+0.28, 012
+0.28 013
+0.28 011
+ 0.38 013
+0.30 013
-0.33 013
+0.35 008
-0.30 008
+0.33 010
-0.39 012
+0.28 010
-0.52 012
-0.51 012
+0.26 009
+0.60 012
-0.46 013
-0.41 012
+0.28 011
-0.39 011
-0.36 012
+0.28 013
+0.28 013
+0.33 012
-.038 012
+0.39 010
-0.39 010
-0.41 010
-0.39 013
-0.36 010
+0.03 013
-0.39 013
+0.26 012
+0.31 007
+0.13 011
-0.62 011
-0.57 011
+0.16 014
-0.59 013
+0.20 014
-0.51 013
-0.49 012
+0.29 012
+0.29 012
+0.28 012
"+0.28 012
-0.56 013
+0.23 008
+0.34 010
+0.62 013
+0.26 008
+0.33 012
-0.38 011
-0.28 013
+0.33 011
+0.39 011
+0.41 013
-0.31 012
-0.52 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 013 LTE LTE LTE 013 LTE LTE LTE
-LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 010 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE 012 LTE LTE 013 LTE LTE.
LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 013 UTE UTE UTE 013 UTE UTE UTE UTE UTE UTE UTE UTE-UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE 012 UTE UTE 013 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR
-WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL # LEG 124 124 124 124 74 0
74 74 74 72 70 46 110 124 124 124 124 124 0
124 0
124 4
120 73 74 74 0
74 73 74 74 0
74 76 76 76 70 48 48 6
118 120 120 118 118
.4 118 120 74 74 3
74 76 5
74 3
70 72 69 70 70 4
70 46 0
46 0
46 144 118 118
-120 120 118 118 6
118 119 120 117 118 6
118 119 120 120 120 74 5
74 76 76 0
76 6
76 72 46 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 51OXE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB
ý510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XP 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XE
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:20 Component: S/G A Page 27 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 91 31 0.09 91 71*
0.05 91 104 0.06 91 114 0.09 91 115 0.14 91 121 0.09 91 124 1.43 0.22 0.38 0.08 91 125 0.11 0.28 0.23 0.08 0.08 91 126 0.23 0.29 0.12 0.09 91 127 0.13 0.07 91 130 0.14 92 4
0.20 92 5
0.18 92 6
0.12 92 116 0.09 0.12 0.27 0.10 92 117 0.26 92 124 0.23 92 125 0.07 92 126 0.20 0.26 92 127 1.04 0.35 93 3
0.11 93 4
0.17 0.08 93 6
0.19 93 118 0.11 0.14 93 121 0.19 93 122 0.08 93 124 0.13 0.07 93
.125 1.25 0.09 0.46 93 126 0.10 94 1
0.07 94 17 0.10 94 121 0.30 0.10 94 123 0.10 94 124 0.21 0.11 94 126 0.05 0.08 0.08 94 127 0.23 0.21 94 129 0.23 95 79 0.09 0.11 95 111 0.06 95 112 0.09 95 116 0.24 95 119 0.18 0.13 95 120 1.88 0.54.
0.22 95 121 0.27 95 122 0.06 95 123 1.51 0.18 0.32 95 124 0.15 0.07 DEG CHN 130 P2 135 P2 136 P2 136 P2 129 P2 147 P2 113 98 140 P2 136 P2 137 P2 143 P2 147 P2 150 P2 148 P2 155 P2 139 P2 143 P2 150 P2 147 P2 146 P2 135 P2 129 P2 146 P2 143 P2 145 P2 140 P2 146 P2 142 P2 137 P2 144 P2 150 P2 144 P2 136 P2 144 P2 114 26 138 P2 149 P2 127 P2 142 P2 146 P2 143 P2 124 P2 143 P2 139 P2 135 P2 74 P2 109 26.
156 P2 138 P2 139 P2 144 P2 146 P2 137 P2 151 P2 146 P2 148 P2 140 P2 125 P2 144 P2 143 P2 143 P2 144 P2 142 P2 147 P2 145 P2 147 P2 103 P2 143 P2 144 P2 143 P2 80 P18 135 P2 143 P2 142 P2 155 P2 115 134 134 P2 145 P2 129 P2 150 P2 IND %TW TWD 7 TWD 4' TWD 5 TWD 7 TWD 11 TWD 7 VOL TWD 16 TWD 24 TWDO 7 TWDO 8 TWD 18 TWD 15 TWD 6 TWD 6 TWD 16 TWD 19 TWD 9 TWD 7 TWD 8 TWD 5 TWD 9 TWD 12 TWD 12 TWD 9 TWD 7 TWD 10 TWD 19 TWD 8 TWD 17 TWD 16 TWD 6 TWD 12 TWD 15 VOL TWD 22 TWD 8 TWD 12 TWD 6 TWD 13 TWD 8 TWD 10 TWD 14 TWD 6 TWD 9 TWD 6 VOL TWD 7 TWD 26 TWD 7 TWD 6 TWD 7 TWD 19 TWD 7 TWD 8 TWD 15 TWD 9 TWD 4 TWD 5 TWD 5 TWD 16 TWD 15 TWD 13 TWD 6 TWD 7 TWD 5 TWD 7 TWD 16 TWD 13 TWD 10 VOL TWD 28 TWD 14 TWD 18 TWD 5 VOL TWD 13 TWD 21 TWD 11 TWD 5 LOCATION 006
-0.54 008
+0.13 009
+0.10 011
-0.57 012
-0.60 008
+0.18 013
+0.28 012
+0.29 013
+0.28 011
-0.39 011
-0.33 011
+0.31 013
-0.41 013
+0.25 012
-0.51 012
-0.41 013
+0.28 013
-0.36 011
+0.33 013
+0.33 013
-0.34
.010
+0.71 010
-0.36 010
-0.36 013
+0.28 011
-0.52 013
-0.55 013
+0.15 014
-0.57 013
-0.54 013
+0.26 011
+0.33 011
+0.38 013
+0.28 013
+0.28 013
+0.28 013
+0.28 010
-0.39 012
-0.36 013
-0.36 012
+0.26 012
-0.54 012
+0.26 013
.+0.23 011
+0.34 011
-0.41 013
+0.23 Oil
+0.33 013
+0.30 012
-0.38 013
+0.39 011
-0.55 012
+0.26 012
-0.49 013
+0.25 011
+0.29 014
+0.31 004
+0.08 011
+0.38 012
-0.31 011
+0.38 013
+0.33 011
+0.36 007
-0.70 008
-0.67 011
-0.57 011
-0.57 013
-0.52 012
-0.52 012
+0.21 013
-0.49 013
-0.49 014
-0.49 013
-0.44 011
+0.31 013
+0.28 011
+0.29 013
+0.26 013
+0.33 013
-0.34 EXT EXT LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 013 013 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 013 013 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 013 013 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 013 013 LTE UTE LTE UTE LTE UTE LTE UTE 013 013 LTE UTE LTE UTE LTE UTE LTE UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR.
WAR WAR WAR 1
UTIL' 2
CAL # LEG 46 144 4
537 120 120
,118
.19 120 120 4'
120 118 118 118 118 4
118 74 74 0
74 0
774 76 3
76 76 70 46 48 120 120 120 5
120 118 120 0
74 76 76 73 74 70 46
- 0.
46 46 118 0
118 120 3
118 3
118 4
118 73 74 74 76 64 6
46 118 5
118 3
118 120 120 76 0
76 4
76 74 74 0
76 8
531 5
531 120 5
118 118 120 120 117 118 118 120 0
118 119 120 120 118 3
118 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510UL 510XB 510XB 510XB 510XP 510XB 510XB 510XB 51MX 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB-510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 51OXB 510XB 510XB 510XB 510XB "510XB 510XB 510XB 510XB 510XB 510UL 510UL 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:20 Component: S/G A Page 28 of 38 Service QUERY: u2sga.qry Induced Degradation ROW 95 95 96 96 96 96 96 96 96 96 96 97 97 97 97 97 97 97 97.
998 98 98 98 98 98 98 98 98 98 99 99 99 99 99 99 99 99 99 99 100 100 100 100 100 100 100 ioo 101 101 101 COL VOLTS 125 0.11 126 0.13 0.47 1.78 2
0.08 3
0.12 5
0.19 6
0.21 103 0.06 109 0.06 114 0.26 120 1.55 0.32 125 0.20 0.21 5
0.09 0.08 86 b.05 0.13 115 0.13 119 0.23 120 0.26 121 1.56 0.35 0.10 0.07 123 0.14 0.09 124 0.15 6
0.24 0.07 7
0.13 8
0.18 19 0.18 26 0.11 74 0.06 122 0.13 0.09 125 1.98 0E50 126 0.11 127 1.32 0.30 0.17 0.09 4
0.18 7
0.10 10 0.15 108 0.17 119 0.24 120 0.16 0.15 123 0.13 124 0.25 0.11 125 0.09 126 2.13 0.18 0.52 0.09 1
0.10 0.05 4
0.10 100 0.16 118 0.14 119 0.06 0.17 0.10 0.06 122 0'.32 1.22 125 0.13 0.21 8
0.12 0.10 15 0.10 0.17 118 1.61 0.41 119 0.10 DEG CHN 145 P2 154 P2 134 P2 113 62 143 P2 132 P2 149 P2 138 P2 142 P2 103 P2 140 P2 80 P18 139 P2 139 P2 143 P2 150 P2 153 P2 97 P2 88 P2 140 P2 141 P2 137 P2 113 158 139 P2 134 P2 145 P2 151 P2 150 P2 143 P2 140 P2 155 P2 152 P2 146 P2 123 P2 148 P2 90 P2 144 P2 146 P2 112 122 132 P2 135 P2 116 122 138 P2 140 P2 152 P2 144 P2 148 P2 139 P2 124 P2 142 P2 147 P2 142 P2 149 P2 145 P2 148 P2 143 P2 111 122 138 P2 138 P2 150 P2 147 P2 157 P2 141 P2 138 P2 145 P2 129 P2 147 P2 136 P2 158 P2 138 P2 113 14 144 P2 145 P2 149 P2 151 P2 144' P2 135 P2 84 P19 138 P2 144 P2 IND %TW TWD 9 TWD 8 TWD 23 VOL TWD 7 TWD 8 TWD 13 TWD 15 TWD 5 TWD 5 TWD 17 VOL TWD 20 TWD 12 TWD 12 TWD 6 TWD 6 TWD 4 TWD 9 TWD 10 TWD 17 TWD 17 VOL TWD 22 TWD 8 TWD 6 TWD 11 TWD 7 TWD 12 TWD 16 TWD 5 TWD 9 TWD 13 TWD 12 TWD 8 TWD 5 TWD 9 TWD 7 VOL TWD 29 TWD 9 VOL TWD 21 TWD 13 TWD 8 TWD 13 TWD 7 TWD 11 TWD 13 TWD 16 TWD 12 TWD 11 TWD 9 TWD 18 TWD 9 TWD 7 VOL TWD 14 TWD 30 TWD 7 TWD 8 TWD 4 TWD 8 TWD 11 TWD 11 TWD 5 TWD 12 TWD 7 TWD 5 TWD 21 VOL TWD 11 TWD 16 TWD 8 TWD 7 TWD 8 TWD 13 VOL TWD 24 TWD 8 LOCATION 011
+0.38 011
+0.41 013
+0.36 013
+0.20 013
-0.36 013
-0.34 014
-0.41 013
-0.39 013
-0.03 012
+0.10 014
-0.59 012
-0.52 012
-0.47 011
+0.38 013
+0.36 012
+0.31 012
-0.47 010
+0.03 008
-0.59 012
-0.55 012
+0.26 013
+0.26 013
+0.28 013
+0.26 014
-0.44 014
+0.23 011
+0.34 013
+0.28 011
+0.37 013
-0.36 010
-0.39 014
-0.46 014
-0.49 013
-0.62 010
+0.10 007
+0.08 014
+0.31 013
-0.39 013.
+0.31 013
+0.36 011
-0.29 013
+0.36 013
+0.39 011
-0.29 011
+0.42 010
-0.36 012
-0.49 014
+0.21 013
-0.63 013
+0.20 013
-0.42 013
+0.28 013
+0.28 013
-0.31 011
+0.37 01i
-0.31 013
+0.34 011
-0.26 013
+0.33 011
+0.44 010
+0.67 008
+0.31 012
+0.36 011
+0.05 012
-0.49 012
+0.28 012
-0.49 013
+0.23 013
-0.46 013
+0.28 013
+0.28 011
-0.29 011
+0.39 013
-0.42 014
+/-0.21 014
+0.13 013
-0.54 013
-0.44 013
-0.44 013
+0.23 EXT LIE LTE LTE LTE 0TE LTE LTE LTE
- LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 013 LTE LTE LIE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 013 LTE LTE 013 LTE LTE LIE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 013 LTE LTE LTE LIE LTE LTE LTE LTE LTE LTE LTE LTE LTE 013 LTE LTE LTE LTE LTE LTE 013 LTE LTE EXT UTIL UTE WAR UTE WAR UTE WAR 013 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 012 WAR DTE. WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 013 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 013 WAR UTE WAR UTE WAR 013 WAR UTE WAR UTE WAR UTE WAR' UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 013 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 013 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 013 WAR UTE WAR UTE WAR 1
UTIL 2
CAL # LEG 74 INLET 76 INLET 76 INLET 75 INLET 72 INLET 70 INLET 46 INLET 48 INLET 118 INLET 4
118 INLET 11 118 INLET 117 INLET 118 INLET 76 INLET 0
76 INLET 46 INLET 5
46 INLET 98 IINLET 0
98 INLET 6
120 INLET 120 INLET 118 INLET 119 INLET 120 INLET 0
120 INLET 0
120 INLET 120
- INLET 7
120 INLET 130 INLET 48 INLET 0
48 INLET 4
46 INLET 48 INLET 46 INLET 46 INLET 144 INLET 118 INLET 4
118 INLET 129 INLET 130 INLET 130 INLET 129 INLET 130 INLET 6
.130 INLET 0
130 INLET 48 INLET
,4 46 INLET 13 48 INLET 5
120 INLET 9
118 INLET 120 INLET 120 INLET 0
118 INLET 130 INLET 4
130 INLET 130 INLET 129 INLET 130 INLET 130 INLET 2
130 INLET 64 INLET 64 INLET 6
48 INLET 118 INLET 120 INLET 0
118 INLET 7
118 INLET
- 3.
118 INLET 0
118 INLET 120 INLET 119 INLET 130 INLET 130.
INLET 46 INLET 46 INLET 48 INLET 5
48 INLET 117 INLET 118 INLET 5
120 INLET PROBE 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 51OXP 510XB 510XB 510XB 51OXB
ý510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:20 Component: S/G A Page 29 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 101 121 0.26 0.11 101 122 0.08 102 2
0.13 102 3
0.16 102 72 0.12 102 99 0.10 102 115 0.10 102 116 0.14 0.18 102 121 0.19 103 6
0.08 103 88 0.08 103 107 0.12 103 110 0.07 103 i17 0.38 1.16 103 118 0.25 0.11 103 123 0.09 103 124 0.10 104 4
0.14 104 99 0.04 104 122 0.10 104 123 0.06 105 3
0.15 105 5
0.08 105 13 0.09 105 107 0.12 105 113 0.29 0.26 0.10 105 114 0.15 0.18 0.09 105 117 0.14 105 122 0.08 106 3
0.07 106 7
0.21 106 10 0.11 106 93 0.14 106 101 0.09 106 111 0.20 106 119 0.08-107 1
0.10 107 5
0.18 107 11 0.08 107 108 0.08 107 110 0.91 0.30 0.11 107 112 0.17-107 117 0.10 108 1
0.10 108 3
0.12 108 6
0.15 108 20 0.07 108 82 0.08 108 92 0.04 108 93 0.07 108 105 0.07 109 96 0.07 109 110 0.09 109 112 0.09 0.13 109 114 0.08 109 115 0.12 110 4
0.13 110 7
0.05 110 101 0.10 110 108 0.14 0.26 110 110 0.13 111 80 0.06 11 90 0.06 111 92 0.09 0.10.
111 97 0.08 111 100 0.12 111 104 0.16 DEG CHN IND %TW 142 P2 TWO 18 144 P2 TWD 9 145 P2 TWD 6 143 P2 TWD 9 139 P2 TWD 11 132 P2 TWD 9 116 P2 TWD 7 144 P2 TWD 8 142 P2 TWD 11 147 P2 TWD 13 141 P2 TWD 13 139 P2 TWD 6 147 P2 TWD 5 153 P2 TWD 9 142 P2 TWD 6 139 P2 TWD 22 116 122 VOL 139 P2 TWD 17 146 P2 'TWD 9
144 P2 TWD 8 146 P2 TWD 8 143 P2 TWD 10 154 P2 TWD 3 149 P2 TWD 9 146 P2 TWD 5 141 P2 TWD 11 118 P2 TWD 6 144 P2 TWD 8 148 P2 TWD 9 144 P2 TWD 18 141 P2 TWD 17 143 P2 TWD 7 151 P2 TWD 12 145 P2 TWD 14 138 P2 TWD 7 149 P2 TWD 10 155 P2 TWD 7 128 P2 TWD 6 139 P2 TWD 15 153 P2 TWD 8 131 P2 TWD 10 152 P2 TWD 7 138 P2 TWD 15 125 P2 TWD 7 141 P2 TWD 7 152 P2 TWD 12 135 P2 TWD 6 150 P2 TWD 7 114 158 VOL 142 P2 TWD 20 144 P2 TWO 9 147 P2 TWD 13 142 P2 TWD 8 150 P2 TWD 7 146 P2 TWD 10 150 P2 TWD 11 113 P2 TWD 5 122 P2' TWD 7 155 P2 TWD 3 151 P2 TWD 6 140 P2 TWD 6 139 P2 TWD 6 130 P2 TWD 7 143 P2 TWD 7 143 P2 TWD 10 136 P2 TWD 7 144 P2 TWD 10 150 P2 TWD 9 148 P2 TWD 5 86 P2 TWD 8 143 P2 TWD 10 143 P2 TWD 17 150 P2 TWD 10 148 P2 TWD 5 130 P2 TWD 5 120 P2 TWD 6 86 P2 TWD 7 142 P2 TWD 7 138 P2 TWD 8 149 P2 TWD 11 LOCATION 013
+0.31 011
+0.34 013
+0.33 011
-0.29 010
-0.34 007
+0.03 011
-0.61 oil
-0.45 012
+0.28 012
-0.48 013
+0.30 012
+0.34 008
+0.10 013
+0.10 013
+0.18 013
+0.23 013
+0.23 013
+0.26 012
+0.26 011
-0.29 008
+0.39 011
-0.29 008
+0.13 011
-0.31 011
-0.31 Ol
-0.31 013
-0.37 012
+0.18 012
+0.13 013
+0.20 014
-0.50 014
+0.26 012
+0.23 013
-0.46 014
-0.48 013
+0.25 008
+0.36 012
-0.39 013
-0.39 013
-0.44 008
-0.56 012
+0.08 012
+0. 21 013
+0.26 013
-0.29 014
-0.44 013
+0.18 011
+0.18 013
+0.13 013
+0.21 Ol1
+0.26 013
-- 0.47 013
+0.29 013
-0.26 013
-0.31 013
-0.36 012
+0.13 008
+0.05 008
+0.15 010
+0.10 014
+0.13 015
-0.03 012
+0.24 013
+0.23 014
-0.44 013
+0.29 013
+0.26 013
-0.34 010
-0.10 012
-0.60 014
-0.53 013
+0.18 013
-0.46 008
+0.05 008
+0.15 011
-0.64 011
-0.08 011
+0.13 011
-0.56 008
+0.23 EXT EXT LTE L:TE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 013 013 LIE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 013 013 LTE UlE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE. UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL WAR~
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 1
UTIL 2
CAL # LEG 120 5
120 4
118 54 54 144 118 0
118 120 8
120
- 5.
136 54 5
531 3
136 5
116 136 135 116 5
116 130 130 54 114 0
130 130 54 0
54 56 114 114 114 4
.114 116 116 5
116 5
136 130 4
56 56 0
54 0
529 114 108 4
108 4
54 54 0
54 2
108 107 108 0
108 108 5
108 4
54 56 54 0
54 4
527 98 4
537
- 6.
108 108 108 108 7
108 0
108 108 0
54 0
56 108 136 136 136 3
527 98 4
106 106 5
108 0
106 6
106 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 51OXE 510XB 510XB 510XB
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:10:20 Component: S/G A Page 30 of 38 Service QUERY: u2sga.qry Induced Degradation ROW COL VOLTS 0.19 111 108 0.10 112 6
'0.08 112 10 0.08 112 11 0.11 112 24 0.09
.0.08 112 96 0.11 112 102 3.66 0.65 0.10 112 104 0.11 0.29 112 105 0.21 0.11 112 117 0.10 113 2
0.08 113 5
0.09 113 7
0.21 113 9
0.16 113 20 0.06 113 74 0.07 113 77 0.08 113 97 0.12 113 103 0.12 113 104 0.19 0.24 113 105 0.15 113 111 0.07 114 3
0.08 114 65 0.10 0.11 0.12 0.10 0.06 114 72 0.07 114 93 0.09 114 103 0.20 0.07 114 107.
0.08 0.07 0.07 114 108 0.22 114 109 0.08 114 115 0.09 115 10 0.10 115 103 0.20
.0.22 115 105 0.13 115 109 0.13 115 114 0.14 0.12 116 10 0.07 116 14 0.10 116 79 0.07 116 86 0.22 116 87 0.06 116 90 0.08 116 99 0.14 116 100 0.07 116 101 0.13 116 106 0.13 116 107 0.11 116 108 0.15 116 112 0.08 0.16 0.09 117 12 0.10 117 70 0.11 117 73 0.26 117 101 0.06 117 104 0.17 117 108 0.31 118 3
0.16 118 4
0.11 118 6
0.06 118 10 0.09 118 16 0.12 0.14 118 67 0.07 DEG 149 146 139 135 156 92 153 127 55 136 132 146 145 142 154 14'6 146 143 145 145 145 129 144 150 135 151 151 142 148 141 75 137 137 100 113 110 120.
149 156 147 156 135 145 141 149 147 147 149 136 146 135 139 152 141 118.
142 141 137 135 143 149 i47 149 147 152 145 117 152 143 137 149 153 146 141 127 136 150 147 140 86 CHN IND %TW P2 TWD 12 P2 TWD 8 P2 TWD 6 P2 TWD 7 P2 TWD 8 P2 TWD 8 P2 TWD 7 P2 TWD 7 3
VOL P2 TWD 30 P2 TWD 7 P2 TWD 7 P2 TWD 17 P2 TWD 15 P2 TWD 9 P2
.TWD 8 P2 TWD 6 P2 TWD 6 P2 TWD 14 P2 TWD 11 P2 TWD 5 P2 TWD 6 P2 TWD 7 P2 TWD 10 P2 TWD 10 P2 TWD 12 P2 TWD 15 P2 TWD 12 P2 TWD 5*
P2 TWD 7 P2 TWD 7 P2 TWD 7 P2 TWD 8' P2 TWD 7 P2 TWD 5 P2 TWD 5 P2 TWD 6 P2 TWD 13 P2 TWD 5 P2 TWD 6 P2 TWD 5 P2 TWD 5 P2 TWD 17 P2 TWD 6 P2 TWD 6 P2 TWD 8 P2 TWD 13 P2. TWD 14 P2 TWD 9 P2 TWD 9 P2 TWD 9 P2 TWD 8 P2 TWD 6 P2 TWD 8 P2 TWD 5 P2 TWD 14.
P2 TWD 5 P2 TWD 8 P2 TWD 10 P2 TWD 7 P2. TWD 9 P2 TWD 11 P2 TWD 8 P2 TWD 13 P2 TWD 6 P2 TWD 11 P2 TWD 7 P2 TWD 8 P2 TWD 8 P2 TWD 18 P2 TWD 6 P2 TWD 11 P2 TWD 18 P2 TWO il P2 TWD 9 P2 TWD 5 P2 TWD 7 P2 TWD 10 P2 TWD 11 P2' TWD 5 LOCATION 011
+0.23 012
+0.21 012
-0.44 012
-0.52 013
-0.44 014
-0.66 014
+0.03 012
-0.61 013
-0.59 013
-0.54 012
-0.64 012
+0.20 013
-0.51 013'
-0.50 014
-0.57 013
-0.31 013
-0.29 013
-0.36 012
-0.42 011
-0.39 010
+0.23 010
+0.08 013
-0.78 014
+0.05 014
-0.53 013
-0.49 013
+0.15 013
-0.46 013
-0.43 011'
-0.29 004
-0.54 006
+0.20 008
-0.59 007
+0.13 010
+0.05 010
+0.08 013
-0.62 013
+0.18 011
+0.15 013
-0.44 014
+0.21 014
-0.49 013
+0.18 014
-0.41 002
+0.43 012
-0.47 013
+0.20 014
-0.51 014
+0.23 013
+0.23 002
-0.25 002
+0.15 013
-0.44 012
-0.54 010
+0.10 014
-0.69 010
+0.16 013
-0.62 014
+0.15 012
-0.50 011
-0.45 013
-0.38 014
-0.43 013
-0.38 008
+0.35 011
+0.41 013
-0.36 013
-0.44 008
-0.57 008
'-0.54 013
+0.20 013
+0.23 013'
-0.38 013
-0.34 013
-0.34 010
+0.29 011
+0.26 013
-0.52 014
-0.56 010
+0.05 EXT LTE LTE LTE LTE LTE LTE LTE LTE 013 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE
'LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTIL UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 013 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE.
WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR;.
UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 1
UTIL 2
CAL #
4 106 5
136 0
56 56 0
54 56 4
56 6
106 105 106 6
106 106 106 108 108 6
108 0
56 4
54 54 54 3
56 2
527 6
525 0
104 6
104 102 102 104 5
106 56 98 98 98 98 98 3
527 0
537 102 3
102 102 102 0
.102 104 102 102 56 102 102 102 102 102 102 110 56 2.
527 98 0
527 104 102 0
104 0
102 104 102 104 136 136 136 64 0
527 7
525 0
104 102 102' 62 64 64 64 64 64 4
527 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET-INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 51 OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
- 510XB, 510UL, 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB.
510XB 510XB.
510XB 510XB 510XB 510XB 510XB 510XB 510UL 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL
AREVA NP Inc.
Customer Name: ONS2 Repl 01/20/09 02:10:20 Component: S/G A Page 31 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 118 97 0.20 118 99 0.08 118 101 0.10 119 1
0.06 119 5
0.15 119 14 0.08 119 58 0.09 119 69 0.11
- 119, 91 0.12 119 92 0.11 120 3
0.09 120 4
0.22 120 6
0.12 120 7
0.14 120 8
0.09 120 72 0.11 120 94 0.11 120 96 0.11 120 97 0.13 120 98 0.11 120 100 0.10 121 1
0.25 121 2
0.18 121 6
0.17 121 7
0.09 0.18 121 20 0.10 121 73 0.08 121 74 0.09 121 76 0.12 121 78 0.08 121 79 0.10 121 97 0.28 1.62 121 100 0.18 121 104 0.09 122 6
0.06 122 19 0.18 122 79 0.18 0.20 0.08 122
'94 0.11 122 95 0.12 0.09 122 99 0.07 122 103 0.10 122 105 0.14 123 9
0.21 123 64 0.07 123 77 0.11 123 79 0.08 123 96 0.10 123 100 0.14 123 103 0.11 124 6
0.07 124 7
0.07 124 10
'0.14 124 44 0.10 124 59 0.13 124 60 0.08 124 86 0.12 124 88 0.09 124 92 0.16 0.06 124 96 0.06 125 5
0.12 125 8
0.11 0.14.
125 12 0.08 125 66 0.09 125 69 0.15 0.07 125 86 0.05 125 89 0.14 0.09 125 91 0.08 125 93 0.10 0.18 0.07 126 2
0.19 DEG 144 146 151 133 140 152 145 144 144 131 138 141 142 141 153 127 139 136 154 152 153 145 142 137 130 148 139 0
149 134 153 0
136 115 151 147 150 142 141 117 147 152 130 134 152 125 122 146 126 125 140 142 137 142 156 151 150 91 130 143 155 134 144 156 152 146 147 141 151 151 130 151 153 138 153 152 138 141 152 140 CHN IND %TW P2 TWD 13 P2 TWD 6 P2 TWD 7 P2 TWD 5 P2 TWD 10 P2 TWD 6 P2 TWD 7 P2 TWD 7 P2 TWD 8 P2 TWD 10 P2 TWD 7 P2 TWD 15 P2 TWD 9 P2 TWD 11 P2 TWD 6 P2 TWD 9 P2 TWD 10 P2 TWD 10 P2 TWD 9 P2 TWD 10 P2 TWD 9 P2 TWD 16 P2 TWD 13 P2 TWD 12 P2 TWD 6 P2 TWD 13 P2 TWD 8 P2 TWD 4 P2 TWD 7 P2 TWD 9 P2 TWD 6 P2 TWD 5 P2 TWD 20 P28 VOL P2 TWD 12 P2 TWD 6 P2 TWD 5 P2 TWD 12 P2 TWD 12 P2 TWD 13 P2 TWD 6 P2 TWD 9 P2 TWD 8 P2 TWD 7 P2 TWD 5 P2 TWD 7 P2 TWD 9 P2 TWD 14 P2 TWD 5 P2 TWD 8 P2 TWD 7 P2 TWD 9 P2 TWD 12 P2 TWD 8 P2 TWD 6 P2 TWD 5 P2 TWD 11 P2 TWD 9 P2 TWD 11 P2 TWD 6 P2 TWD 10 P2 TWD 8 P2 TWD 13 P2 TWD 5 P2 TWD 6 P2 TWD 9 P2 TWD 9 P2 TWD 11 P2 TWD 7 P2 TWD 6 P2 TWD 10 P2 TWD 5 P2 TWD 5 P2 TWD 9 P2 TWD 6 P2 TWD 6 P2 TWD 7 P2 TWD 12 P2 TWD 5 P2 TWD 13 LOCATION 013
+0.20 013
+0.20 013
+0.08 013
-0.31 014
-0.41 012
-0.49 013
-0.75 010
+0.10 014-
+0.13 013
-0.54 013
-0.31 013
-0.34 010
+0.34 013
-0.36 012
+0.36 013
-0.68 013
+0.18 012
+0.23 014
-0.49 013
-0.46 014
-0.41 013
-0.29 013
-0.31 010.
+0.31 010
+0.26 013
-0.39 014
+0.03 013
-0.68 013
+0.00 011
-0.62 014
+0.00 013
-0.67 012
+0.26 012
+0.23 014
-0.41 013
+0.28 014
-0.39 014
-0.54 013
+0.03 014
-0.69 014
+0.03 014
-0.48 013
+0.26 014
+0.23 014
-0.41 011
-0.31 008
+0.36 013
-0.42 010
+0.10 013
-0.65 011
-0.56 014
-0.46 013
+0.28
'011
-0.31 013
-0.36 013
-0.39 014
-0.46 013
-0.65 014
+0.00 010
+0.10 013
-0.51 014
+0.23 012
+0.26 012
-0.41 010
-0.43 012
+0.34 014
+0.26 013
-0.36 013
+0.26 014
+0.03 013
-0.65 013
+0.03 013
-0.54 011
+0.26 014
+0.21 013
-0.41 012
-0.49 012
+0.34 014
-0.44 013
-0.29 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE
.UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE.
UTE UTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL # LEG 102 INL]
4 102 INL]
102 INL]
62 INL]
62 INL]
0 64 INL]
5 525 INLE 98 INL]
102 INL]
104 INL]
64 INL]
62 INL]
3 62 INLI 64 INLI 62 INL]
6 523 INL]
104 INL]
104 INLI 0
102 INL]
0 104 INL]
104 INLI 62 INLI 64 INLI 0
64 INLI 62 INLI 62 INLI 64 INLI 5
521 INLI 98 INLG 0
523 INLI 98 INLI 9
521 INLI 104 INLI 103 INL]
102 INL]
0 102 INLI 3
64 INLG 62 INLE 98 INL]
98 INLE 4
98 INLE 0
104 INLG 102 INLE 0
102 INLE 102 INLE 102 INLI 102 INLG 62 INLE 98 INLG 98 INLI 4
100 INLI 104 INLI 104 INLl 102 INLI 64 INLI
.0 62 INLI 64 INLI 5
519 INLG 100 INLE 98 INL]
104 INLI 0
104 INLE 104 INLE 4
104 INLE 104 INLE 62 INL]
64 INLI 0
64 INLE 3
64 INLI 98 INLI 98 INLI 98 INLI 104 INLI 0
102 INLI 0
102 INLl 102 INLl 102 INLI 102 INLI 102 INLE 62 INL]
ET ET ST ST ET ST ET ST ST ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET PROBE 510OXB 510XB 510XB 510XB 510XB 510XB 51OUG 510XB 510X 510XB' 510XB 510XBE 510XB 510XB 510XB 51OXB 510XB 510UX 510XBE 510XB 510XBo 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510 XE 510 XE
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:21 Component: S/G A Page 32 of 38 Service QUERY: u2sga.qry Induced Degradation ROW COL VOLTS 126 3
0.06 126 32 0.13 126 38 0.13 126 42 0.12 126 58 0.11 126 60 0.09 126 82 0.10 126 94 0.08 126 97 0.08 127 9 "
0.12 127 25 0.05 0.06 127 69 0.08 127 83 0.13 127 85 0.06 127 86 0.16 127 87 0.22 127 88 0.13 0.10 127 91 0.07 127 92 0.32 127 94 0.09 128 9
0.06 128 10 0.11 0.12 128 64 0.14 0.10 128 86 0.11 0.11 128 87 3.00 0.68 0.09 0.09 128 92 0.08 128 95 0.10 0.19 0.15 129 8
0.09 129 14 0.13 0.05 129 51 0.10 129 52 0.09 129
- 56 0.10 129 57 0.09 129 65 0.08 129 70 0.06 129 74 0..13 129 83 0.07 129 85 0.19 0.11 129 94 0.10 0.20 0.08 130 7
0.12-130 8
0.08 0.06 130 51 0.08 130 57 0.10 0.11 O.OA 130 86 0.12 130 87 0.11 0.14 130 88 0.07 130 92 0.05 0.14 130.
93 0.17 0.17 0.09 131 6
0.09 131 12 0.09 131 15 0.07 131 18 0.13 131 27 0.06 131 52 0.11 131 55 0.07 131 65 0.20 0.14 131 67 0.10 0.08 DEG CHN IND %TW 151 P2 TWD 5 107 P2 TWD 10 142 P2 TWO 9 128 P2 TWD 8 127 P2 TWO 8 143 P2. TWO 6 154 P2 TWO 7 147 P2 TWO 7 143 P2 TWO 6 154 P2 TWO 8 144 P2 TWO 5 120 P2
-TWD 5 0
P2 TWO 4 138 P2 TWO 11 108 P2 TWO 6 148 P2 TWO 11 133 P2 TWO 17 152 P2 TWO 9 150 P2 TWO 7 147 P2 TWO 6 144 P2 TWO 19 157 P2 TWO 6 150 P2 TWO 5 148 P2 TWO 8 150.P2 TWO 8 155 P2 TWO 10 161 P2 TWO 7 145 P2 TWO 10 156 P2 TWO 10 82 P5 VOL 135 P2 TWD 31 153 P2 TWO 7 148 P2 TWD.6 138 P2 TWD 7 133 P2 TWD 7 139 P2 TWO 12 147 P2 TWO 10 139 P2 TWO 7 139 P2 TWD-10 155 P2 TWO 4 124 P2 TWD 5 128 P2 TWD 6 118 P2 TWO 9 157 P2 TWD 6 148 P2 TWD 7 160 P2 TWO 4 138 P2 TWD 9.
153 P2 TWD 6 147 P2 TWD 15 150 P2 TWD 10 142 P2 TWD 7.
148 P2 TWD 13 137 P2 TWD 6 139 P2 TWD 9 148 P2 TWD 7 132 P2 TWD 5 120 P2 TWD 6 81 P2 TWO 7 127 P2 TWO 8 155 P2 TWD 3 146 P2 TWO 10 149 P2 TWD 8 141'P2 TWO 10 160 P2 TWD 7 151 P2 TWD 5 149 P2 TWD 12 145 P2 TWD 11 145 P2 TWD 11-128 P2 TWD 6 141 P2 TWD 7 148 P2 TWD 7 146 P2 TWD 6 148 P2 TWD 9 143 P2 TWD 5 118 P2 TWD 8 152 P2 TWD 7 137 P2 TWD 16 147 P2 TWD 12 121 P2 TWD 9 143 P2 TWD 7 LOCATION 013
-0.34 013
-0.57, 014
+0.00 013
-0.67 013
-0.68 010
+0.10 014
+0.13 013
+0.25 013
-0.31 012
+0.34 013
+0.13 014
+0.03 007
-0.53 012
-0.54 008
-0.48 014
-0.49 014
-0.48 013
-0.41 014
-0.46 012
-0.46 013
-0.36 012
-0.41 012
+0.29 013
-0.42 014
-0.44 014
+0.00 013
+0.05 013
-0.44 013
+0.23 012
-0.49 012
-0.49 013
-0.44 013
+0.15 012
-0.38 010
+0.69 011
-0.28 011
+0.39 014
+0.26 013
+0.23 013
-0.44 011
-0.61 013
-0.65 013
-0.62 014
+0.03 010
+0.18 014
+0.05 011O
-0.52 012
+0.26 014
-0.43 014
+0.26 011
-0.28 011
+0.41 013
-0.31 013
-0.39 014
-0.41 013
-0.36 011
-0.56 012
-0.59 014
-0.64 013
+0.10 014
-0.43 013
.- 0.36 014.
+0.34 010
-0.38 008
+0.36 011
+0.43 011
-0.26 012
-0.36 009
-0.31 013
+0.26 013
-0.39 013
-0.36 014
-0.51 010
+0.18 013
-0.60 010
+0.15 014
-0.58 014
+0.08 014
-0.59 014
+0.13 EXT EXT UTIL 1
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTEUTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR
-LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTEUTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE, WAR LTE-UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR UTIL 2
CAL #
0 64 6
519 78 78 98 98 4
98 5
104 102 8
62 4
80 3
80 4
521 5
104 0
104 102 104 102 102 0
104 102 102 0
64 62 62 98 98 104 4
104 101 102 0
102 3
102 0
104 102 102
-102 0
64 64 64 4
521 98 100 98 100 98 98 0
104 104 104 102 102 102 0
62 64 0
64 6
523 98 98 98 100 98 98
.5 100 100 4
100 98 98 4
98 0
64 64 5
80 78 4
80 98 4
100 100 100 100 100 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:21 Component: S/G A Page 33 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 131 69 0.07 0.06 131 71 0.09 131 87 0.09 132 8
0.17 132 12 0.09 132 29 0.06 132 55 0.12 132 59 0.27 0.13 132 70 0.08 132 71 0.13 0.08 132 80 0.09 132 82 0.10 132 84 0.10 132 87 0.16 133 6
0.04 133 35 0.09.
133 47 0.06 133 53
.0.10 133 73 0.08 0.11 133 77 0.06 0.12 133 78 0.21 133 79 0.09 133 80 0.11 133 84 0.10 133 86 0.16 134 9
0.18 134 17 0.04 134 48 0.09 0.10 134 58 0.13 134 68 0.07 134 71 1.93 0.47 134 77 0.06 134 81 0.09 134 83 0.07 134 85 0.10 0.08 135 8
0.07 135 12 0.14 135 13 0.06 135 35 0.15 135 39 0.08 135 52 0.16 135 62 0.15 135 66 0.26 135 67 0.08 135 72 0.20 0.14 135 79 0.06 136 17 0.09 136 19 0.14 136 29 0.06 136 46 0.15 136 52 0.11 136 56 0.07 136 59 0.06 136 67 1.36 0.15 0.26 0.34 0.11 136 68 0.24 0.15 136 69 1.56 0.27 0.40 0.30 0.12 136 71 0.10 0.13 0.11 136 73 1.39 0.40 136 74 0.13 DEG CHN 142 P2 145 P2 140 P2 152 P2 148 P2 140 P2 144 P2 124 P2 139 P2 141 P2 118 P2 139 P2 126 P2 137 P2 132 P2 152 P2 139 P2 142 P2 137 P2 141 P2 152 P2 142 P2 138 P2 149 P2 151 P2 145 P2 153 P2 145 P2 144 P2 142 P2 144 P2 162 P2 144 P2 153 P2 149 P2 132 P2 83 P8 141 P2 165 P2 107 P2 150 P2 148 P2 124 P2 147 P2 139 P2 133 P2 143 P2 63 P2 134 P2 137 P2 143 P2 144 P2 151 P2 141 P2 140 P2 148 P2 147 P2 138 P2 146 P2 150 P2 158 P2 147 P2 94 P12 142 P2 139 P2 143 P2 157 P2 143 P2 142 P2 86 P8 147 P2 145 P2 146 P2 117 P2 141 P2 149 P2 148 P2 88 P8 138 P2 143 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD.
TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWO VOL TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD
%TW LOCATION 6
011
-0.53 6
013
+0.18 8
013
-0.54 9
013
+0.31 12 014
-0.43 7
012
-0.49 5
011
+0.16 8
012
-0.64 17 012
-0.64 9
012
+0.16 8
012
-0.54 9
014
-0.56 6
014
+0.16 8
011
-0.38 9
013
-0.39 9
013
+0..31 11 011
-0.31 4
013
-0.39 7
014
+0.10 6
013
+0.10 9
010
+0.20 7
011
-0.38 10 011
+0.28 6
012
-0.46 11 014
-0.46 14 012
--0.49 9
014
+0.28 8
014
-0.41 7
013
+0.33 11 010
+0.67 12 013
+0.28 4
014
+0.21 9
014
-0.58 9
014
+0.10 11 013
+0.13 6
013
-0.52 013
-0.44 25 013
-0.44 5
013
-0.39 6
013
-0.34 5
013
+0.36 7
011
-0.31 6
006
-0.30 6
012
+0.36 10 0i2
-0.52 5
012
"+0.28 12 013
-0.57 7
- 012,
-0.62 11 012
-0.59 10 012
-0.57 16 013
-0.47 7
011
+0.26 13 012
-0.46 9' 012
+0.31 6
013
-0.36 8
013
-0.39 11 012
+0.26 4
014
+0.17 12 014
+0.13 9
007
-0.53 6
014
+0.13 4
007
-0.51 014
-0.54 10 011
-0.44 16 013
+0.23 20 014
-0.51 8
013
-0.44 17 013
-0.44 12 013
+0.20 013
-0.47 17 010
-0.44 22 013
-0.44 18 013
+0.23 8
014
+0.26 7
012
-0.52 9
013
-0.39 8
614
-0.44 013
-0.54 23 013
-0.39 12 013
+0.26 EXT EXT
- LTE UTE LTE UTE LTE UTE ILTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 013 013 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 014 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 013 013 LTE UTE LTE UTE LTE UTE LTE UTE
.LTE UTE LTE UTE LTE UTE 013 013 LTE UTE LTE UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 1
UTIL 2
CAL 100 4
100 100 0
100 64 64 4
80 98 98 3
98 0
100 4
98 3
98' t00 100 4
100 98 64 4
80 0
.100 100 100
-100 100 100 98 5
100 98 98 98 62 84 100 100 7
100 96 93 94 98 98 0
98 98 98 0
64 7
82 84 84 84 11 94 94 94 0
96 94 6
94 100 5
84 84 84 96 96 4
96 94 93 94 94 94 0
94 96 0
96 93 94 94 94
,5 94 94 0
94 0
94 93 94 100
- LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
'510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB
- 510XB, 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:21 Component: S/G A Page 34 of 3*8 Service QUERY: u2sga.qry Induced Degradation ROW 136 136 137 137 137 137 137 137 137 137 137 137 137 137 137 137 138 138 138 138 138 138 138 138 138 138 138 138 138 138 138 138 138 139 139 139 139 139 139 139 139 139 139 139 139 139 139 139 139 139
.139 139 139 139 140-140 140 140 140 140 140 140 COL 78 80 6
27 35 42 50 52 54 62 63 64 66 69 70 76 78 9
22 43 47 48 49 53 54 57 62 63 64 67 69 73 10 11 14 19 23 25 27 2938 43 53 "56 60.
62 63 66 68 69 70 72 74 10 11 13 19 24 25 26 42 VOLTS 0.13 0.15 0.04 0.17 0.06 0.13 1.32 0.46 0.13 0.16 0.04 0.09 0.15 0.18 4.44 1.18 0.06 0.14 0.15 0.09 0.08 0.12 0.11 0.13 0.12 0.11 0.10 0.13 0.17 0.14 0.31 0.05 1.89 0.28 0.08 0.07 0.18 0.17 0.14 0.12 0.21 0.17 0.07 0.18 0.12 0.16 0.08 0.18 0.13 0.10 0.09 0.15 0.06 0.15 0.10 0.17 0.11 0.11 0.14 0.28 0.13 0.15 0.06 0.18 0.14 0.17 0.12 0.14 0.22 0.14 0.10 0.13 0.09 0.12 0.12.
0.15 0.10 0.'
10 0.17 DEG CHN 139 P2 124 P2 152 P2 142 P2 152 P2 131 P2 90 P9 132 P2 143 P2 144 P2 128 P2 158 P2 149 P2 140 P2 144 P2 82 P28 128 P2 127 P2 150 P2 148 P2 142 P2 152 P2 151 P2 131 P2 142 P2 150 P2 145 P2 150 P2 145 P2 153 P2 152 P2 143 P2 150 P2 37 P23 143 P2 147 P2 145 P2 141 P2 151 P2 146 P2 141 P2 132 P2 150 P2 138 P2 143 P2 132, P2 133 P2 144 P2 141 P2 140 P2 142 P2 159 P2 144 P2 155 P2 136 P2 156 P2 145 P2 124 P2 140 P2 143 P2 146 P2 155 P2 150 P2 151 P2 150 P2 149 P2 151 P2 147 P2.
144 P2 145 P2 153 P2 137 P2 143 P2 139 P2 137 P2 152 P2 146. P2 147 P2 155 P2 153 P2 IND TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD.
TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TwO TWD
%TW LOCATION 11 010
-0.35 13 013
-0.31 4
011
-0.33 12 012
+0.34 6
014
+0.21 10 014
+0.08 014
-0.69 25 014
-0.59 9
014
+0.13 11 013
-0.47 3
013
+0.15 6
011
-0.47 10 014
+0.18 9
013
+0.20 12 013
-0.44 010
-0.54 42 010
-0.44 5
013
+0.26 9
013
+0.28 10 013*
+0.33 6
013
-0.34 7
014
-0.36 8
012
-0.47 8
013
+0.20 11 014
-0.49 10 014
+0.21 9
015
+0.50 8
013
-0.52 10 014
+0.16 12 014
+0.16 11 013
-0.54 20 014
-0.51 5
008
-0.46 014
-0.51 17 014
-0.51 6
012
-0.49 6
014
+0.18 12 011
-0.41 11 013
-0.44 10 013
+0.26 9
010
-0.43 15 013
+0.23 11 013
+0.26 6
013
-0.44 13 013
+0.31 8
010
-0.36 10 014
+0.29 7
012
-0.44 11 014
-0.43 10 012
-0.52 8
012
-0.55 8
013
-0.41 12 012
-0.60 6
013
+0.23 10 014
+0.13 8
013
-0.52 13 013
-0.49 8
012
+0.23 8
014
-0.54 9
013
+0.26 17 013
+0.26 9
014
+0.23 10 013
-0.44 5
013
-0.41 12 010
-0.39 9
013
+0.28 11 010
-0.36 9
012
-0.39 10 013
-0.34 14 013
+0.33 9
011
+0.39 8
011
+0.34 11 012
-0.50 6
013
-0.34 8
013
-0.34 8
014
+0.26 12 011
-0.36 7
013
-0.41 8
014
+0.21 12 013
-0.47 EXT EXT UTIL 1
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 014 014 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 010 010 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 014 014 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE'UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE'UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR
-LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR UTIL 2
CAL #
100 100 100 62 84 84 93 94 94 94 94 94 94 96 94 93 LAR 94 96 94 98 0
82 84 0
82 0
82 84 84 84 96 96 94 96 96 96 95 94 96 96 94 94 94 96 96 94 96 96 98 82 0
84 6
82 84 84 84 9
84 84 94 96 96 94 94 94 94 94 0
94 96 94 0
94 94 0
96 94 98 98 4
84 7
84 0
82 0
82 82 84 82 84 94 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
-510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:10:21 Component: S/G A Page 35 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL 140 46 140 50 140 56 140 59 140 60 140 140 140 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 141 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 142 143 143 143 143 143 143 VOLTS 0.07 0.19 0.11 0.16 0.19 0.13 0.13 0.14 0.14 0.09 2.12 0.45 0.08 0.06 0.13 0.22 0.10 0.11 0.05 0.08 0.13 0.30 0.07 0.09 0.10 0.11 0.15 0.22 0.10 0.10 0.17 0.20 3.21 0.78 0.23 0.13 0.14 0.07 2.37 0.54 0.17 0.15 0.21 0.13 0.07 0.09
.0.16 0.23 0.25 0.32 0.18 0.07 0.07 0.08 0.07 0.07 0.11 0.12 0.06 0.06 0.16 0.19 0.26 0.14 0.10 0.09 0.31 0.07 0.19 0.15 0.21 0.16 0.17 0.09 0.13 0.13 0.06 0.28 0.48 0.09 DEG 139 151 138 144 140 151 147 153 143 155 81 142 100 150 144 143 147 151 159 140 141 141 132 154 153 147 155
.148 151 142 149 147 83 133 139 152 144 153 82 135 141 134 148 153 137 147 141 142 141 138 148 150 156 139 152 157 141 155 151 130 141 148 141 150 141 147 139 134 152 134 134 145 145 137 150 150 152 138 139 144 CHN IND P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P28 VOL P2 TWO P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD
%TW 5
13 8
11 12 11 10 9
9 6
24 6
4 9
16 9
9 57 11 185 7
8 9
10 16 8
7 13 15 34 15 9
1]1 6
27 12 11.
15 9
6 8
10 14 15 18 14 6
5 7
5 6
9 9
5 5
11 12 18 10 8
8 19 6
12 10 15 13 11 6
11 9
5 16 25 6
LOCATION 013
+0.15 014
+0.21 014
-0.51 012
-0.54 010
-0.36 013
-0.41 013
+0.26 013
+0.26 010
-0.41 013
-0.41 010
-0.46 010
-0.41 012
+0.28 007
+0.33 012
-0.47 011
+0.34 011
-0.31 013
+0.31 014
-0.44 012
-0.55 014
+0.29 013
-0.47 013
+0.23 014
+0.18 013
-0. 52 010
-0.49 013
-0.41 013
-0.44 013
+0.23 013
-0.44 013
-0.44 013
-0.41 010
-0.49 010
-0.44 014
+0.29 010
-0.39 013
-0.41 013
+0.31 010
-0.54 010
-0.44 013
-0.36 011
-0.34 011
-0.31 013
+0.28 013
-0.36 012
+0.39 012
-0.47 013
-0.31 012
-0.49 014
-0.46 014
-0.49; 014
+0.21 012
+0.26 012
+0.26 011
-0.36 012
-0.54 011
-0.38 012
-0.54 012
+0.23
.014
-0.51 013
-0.36 010
+0.62 014
-0.43 012
-0.49 010
-0.33 013
-0.46 013
-0.34 013
-0.39 013
-0.31 013
+0.33 011
-0.31 013
-0.33 013
+0.36 013
+0.26 013
+0.33 013
-0.36 014
-0.41 013
+0.31 014
-0.51 013
-0.49 EXT EXT UTIL LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 010 010 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 010 010 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 010 010 WAR ITE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 94 94 0
94 94 5
94 96 96 94 0
94 0
.94 93 94 94 98 0
82 84 0
84 84 84 84 84 82 82 96 96 96 94 96 4
96 94 96 96 93 94 94 0
94 96 4
96 93 94 94 94 96 4
94 96 84 82 82 82 82 84 84 82 96 94 96 0
96 96 96 96
.94 3
94 96 94 96 0
96 94 96 94 94 96 96 4
94 3
82 84 82 84 82 82 82 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET' INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
.510XB 510XB 510XB 510XB 51OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 1
UTIL 2
CAL # LEG PROBE C
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:21 Component: S/G A Page 36 of 38 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 1.85 143 25 0.12 143 27 0.14 143 28 0.11 143 29 0.21 143 30 0.21 143 39 0.13 143 40 0.30 143 43 0.14 143 58 0.10 0.08 143 59 0.07 0.10 143 60 0.10 143 61 0.10 143 62 0.12 0.10 144 7
0.06 144 15 0.11 144 17 0.20 144 18 0.11 144 19 0.18 144 20 0.18 0.08 0.09 0.14 144 21 0.07 0.0.6 144 23 0.17 144 27 0.08 144 33 0.21 144 37 0.07 144 38 0.12 144 39 0.08 144 40 0.18 144 44 0.10 144 50 0.09 0.12 144 52 0.09 144 54 0.05 144 55 0.11 145 8
0.13 145 10 0.08 145 12 0.18 145 13 0.14 145 14 0.13 0.42 1.07 145 15 0.09 145 17 0.08 145 18 0.11 145 19 0.09 145 20 0.22 0.08 145 22 0.13 145 27 6.08 145 28 0.10 145 32 0.09 145 35 0.07 0.15 145 36 0.06 145 39 0.14 145\\ 40 0.17 145 46 0.13 145 47 0.08 145 49 0.10 146 12 0.07 146 16 0.12 0.09 146 19 0.21 146 21 0.11 0.16 146 22 0.26 0.07 146 23
,0.32.
146 27 0.13 0.27 0.16 146 29 0.07 146 33 0.12 DEG 139 148 156 152 144 152 145 142 148 142 142 142 149 149 135 146 150 143 138 143 150 144 145 147 142 144 142 153 139 154 150 151 152 130 145 141 146 149 119 154 145 134 157
'152 139 157 137 114 152 150 147 142 141 1 53 156 145 150 141 156 143 155 1*49 145 139 150 136 137 145 156 143 138 145 143 145 138 149 140 148 151 141 CHN IND 30 VOL P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2
'TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD
- 86.
VOL P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD
%TW LOCATION 014
-0.64 10 013
+0.25 11 013.
-0.44 7
014
-0.48 16 014
-0.48 13 012
-0.54 10 014
+0.23 18 014
-0.49 11 013
-0.44 7
013
-0.31 6
013
+0.33 6
011
-0.28 8
013
+0.33 7
011
+0.39 8
013
+0.33 8
013
-0.31 7
013
+0.38 5
012
+0.36 10 013
-0.39 15 011
-0.31 7
012
-0.47 14 011
-0.33 12 011
-0.39 6
012
-0.52 6
013
-0.39 9
013
+0.28 6
008
-0.41 5
013
-0.39 13 013
+0.28 7
014
-0.43 14 014
-0.49 5
008
-0.41 9
012
-0.52 6
013
-0.39 13 014
-0.43 8
013
+0.26 7
013
-0.36 9
013
+0.31 8
011
-0.31 4
012
-0.39 8
013
-0.31 9
013
-0.34 5
012
+0.36 12 013
-0.36 12 013
-0.36 9
012
-0.47 22- 014
+0.31 014
+0.16 8
013
-0.36 7
012
-0.44 7
.012
-0.49 7
011
-0.34 14 011
+0.34 6
012
-0.49 9
012
-0.49 7
012
+0.31 7
011
-0.36 6
006
-0.33 6
012
-0.47 11 013
-0.41 5
008
-0.36 11 012.
+0.31 11 013
+0;33 9
012
-0.46 7
O11
-0.33 8
006
-0.35 6
013
-0.36 10 014
+0.29 8
012
-0.44 13 011
-0.34 7
011
-0.34 11 014
-0.46 18 013
-0.36.
6 013
+0.31 19 012
-0.49 9
011
-0.36 17 013
-0.39 11 013
+0.28 5
011
-0.34 8
011
-0.36 EXT EXT 014 014 LTE UTE LTE UTE LTE UTE.
LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE
.LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE.
014 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTEUTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR.
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 1
UTIL 2
CAL 81 84 84 82 84 82 92 90 92 90 90 96 96 94 0
96 94 94 84 6
84 84 82 84 82 82 82 3
82 84 84 84 84 90 90 92 90 92 92 92 92 92 92 90 82 82 82 84 82 82 81.
84 84 82 88 86 86 86 92 90 90 92 92 90 92 90 90 92 92 88 88 0
88 86 86 86 88 88 86 90 90 90 90 90
- LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XýB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:22 Component: S/G A Page 37 of 38 Service.Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 146 36 0.13 146 44 0.15" 146 46 0.08 146 51 0.12 147 3
0.22 147 4
0.07 147 6
0.05 147 12 0.19 147 13 0.08 147 15" 0.67 0.30 0.10 147 17 0.17 0.12 147 18 0.51 0.40 1.55 1.21 147 22 0.34 147 23 1.90 0.43 0.08 147 26 0.19 147 27 0.27 147 30 0.13 147 32 0.79 0.11 0.32 0.13 0.41 147 37 0.10 147 40 0.26 147 46 0.10 148 8
0.07 148 15 1.52 0.27 0.39 148 16 0.13 148 19 0.07 148 20 0.15 148 27 0.09 148 32 0.06 148 34 0.08 149 2
0.20 149 5
0.07 149 6
0.08 149 7
0.08 149 17 0.10 149 18 0.15 149 21 0.06 149 25 1.94 0.41 0.12 149 27 0.12 0.15 149 31 0.12 149 32 0.30 0.29 149 34 1.03 0.18 0.23 0.29 0.36 0.08 0.20 150 3
0.12 0.23 0.09 150 4
0.14 150 7
0.10 150 12 0.13 150 13 0.10 150 14 0.07 150' 16 0.11 150 21 0.20 150 24 0.10 150 26 0.13 0.06 150 27 0.07 0.13 DEG CHN IND %TW LOCATION 150 141 150 144 138 135 143 146 152 126 137 148 124 146 133 143 123 115 146 121 133 159 143 143 159 29 132 132 154 134 151 145 148 155 123 130 138 146 150 151 135 161 108 145 148 144 153 144 148 150 302 137 127 144 147 141 135 144 38 144 141 138 149 148 143 150 146 131 138 133 141 156 135 145 137 142 134 143 129 128 P2 TWD 10 P2 TWD 11 P2 TWD 7 P2 TWD 8 P2 TWD 16 P2 TWD 5 P2 TWD 4 P2 TWD 12 P2 TWD 7 134 VOL P2 TWD 20 P2 TWD 8 P2 TWD 13 P2 TWD 10 P2 TWD 26 P2 TWD 22 114 VOL 122 VOL P2 TWD 19 P17 VOL P2 TWD 26 P2 TWD 7 P2 TWD 13 P2 TWD 19 P2 TWD 9 Q14 VOL P2 TWD 8 P2 TWD 19 P2 TWD 9 P2 TWD 22 P2 TWD 8 P2 TWD 16 P2 TWD 7 P2 TWD 5 6
VOL P2 TWD 19 P2 TWD 24 P2 TWD 9 P2 TWD 6 P2 TWD 10 P2 TWD 7 P2 TWD 5 P2 TWD 7 P2 TWD 13 P2 TWD 6 P2 TWD 6 P2 TWD 7 P2 TWD 8 P2 TWD 10 P2 TWD 6 P10 VOL P2 TWD 25 P2 TWD 9 P2 TWD 10 P2 TWD 12 P2 TWD 10 P2 TWD 18 P2 TWD 18 Q3
'VOL P2 TWD 12 P2 TWD 14 P2 TWD 18 P2 TWD 21 P2 TWD 6 P2 TWD 13 P2 TWD 8 P2 TWD 15 P2 TWD 6 P2 TWD 11 P2 TWD 7 P2 TWD 10 P2 TWD 7 P2 TWD 6 P2 TWD 9 P2 TWD 13 P2 TWD 8 P2 TWD 10 P2 TWD 5 P2 TWD 5 P2 TWD 9 010 Oili Oili 002 Oili 013 012 013 013 013 013 Oili 013 012 012 013 012 013 012 013 013 012 012 012 012 013 Oili 012 013 013 Oili Oili 013 012 013 012 013 013 015 013 Oili Oili 013 013 013 012 013 013 012 006 013 013 010*
Oili 013 Oili
.011 012 015 015 Oili 013 015 015 013 012 013 006 012 013 Oili 012 012 012 012 013 Oill 013 007 Ol
+0.62
-0.31
-0.33
-0.25
-0.31
-0.31
-0.44
+0.33
+0.33
-0.39
-0.36
-0.31
-0.36
+0.28
-0.46
-0.36
-0.52
-0.36
-0.44
-0.55
-0.36
-0.47
-0.44
-0.44
-0.47
+0.28
+0.34
-0.44
-0.36
+0.33
-0.31
-0.28
+0.38
+0.42
-0.42
-0.42
-0.34
+0.28
-0.47
+0.33
-0.31
-0.36
+0.34
+0.38
+0.31
-0.39
-0.34
-0.36
-0.36
-0.34
+0.28
+0.36
+0.54
-0.33
+0.38
-0.31
+0.39
-0.36
+0.53
-0.31
-0.31
+0.36
+0.64
-0.42
-0.31
-0.36
+0.38
-0.31
-0.36
-0.34
-0.31
-0.39
-0.42
-0.39
-0.39
+0.31
-0.28
-0.34
-0.31
-0.31 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE 013 LTE LTE LTE LTE LTE LTE "012 013 LTE 013 LTE LTE LTE LTE LTE 013 LTE LTE LTE LTE LTE LTE LTE LTE 013 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 013 LTE LTE LTE LTE LTE LTE LIE 015 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE
- TE EXT UTIL UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 013 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 012 WAR 013 WAR UTE
ýWAR 013 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 013 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 013 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 013 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 015 WAR UTE WAR UTE WAR UTE WAR UTE.
WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 1
UTIL 2
CAL #
0 92 92 0
92 90 8
88 86 86 86 6
88 87 88 3
88 88 5
88 86 86 85 85 86 91 92 6
92 90 92 0
90 89 90 90 90 90 0
.92 90 90 86 87 88 88 5
86
- 88 86 90 92 92 86 88 0
86 88 92 90 92 91 92 5
9 92 4
92 92 90 90 89 90 90 90 90 90 3
90 86 86 86 88 0
86 4 88 86 92 92 90 5
92 92 92 90 90 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510kB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:10:22 Component:
S/G A Page 38 of 38 Service Induced Degradation QUERY: u2sga.qry ROW 151 151 151 151 151 151 151 151 COL 1
4 5
6 7
9 13 16 VOLTS 0.09 0.07 0.17 0.09 0.22
.0.09 0.21 0.11 1.87 0.72 DEG 133 148 138 139 148 143 140 137 35 136 CHN IND P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD Q3 VOL P2 TWD
%TW 7
6 11 7
14 6
14 8
32 LOCATION 008
-0.31 013
-0.34 013
+0.38 003
-0.25 013
-0.31 011
-0.34 013
+0.36 006
-0.33 015
+0.53 015
+0.62 EXT LTE LTE LTE LTE LTE LTE LTE LTE 015 LTE EXT UTE UTE UTE UTE UTE UTE UTE UTE 015 UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 1 UTIL 2
CAL # LEG 88 88 86 88 86 0
86 9090 89 90 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB Total Tubes
- 2006 Total Records: 2970
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:40 Component: S/G B Page 1 of 46 Service Induced Degradation QUERY: u2sg ROW COL VOLTS 1
.1 0.12 1
2 0.07 1
9 0.09 2
8 0.11 2
12 0.21 2
14 0.13 2
16 0.29 1.11 2
18 0.09 2
25 0.13 2
26
.0.08 0.15 2
27 0.18 0.22 3
3 0.06 3
6' 0.11 3
24 0.11 3
29 0.25 3
32 2.14 0.92 0.11 3
34 0.15 4
5 0.07 4
8 0.16 4
1i 0.06 4
14 0.13 4
19 0.08 4
21 0.17 0.17 0.13 4
22 0.09 4
25 0.11 4
35 0.07 4
36 0.09 5
5 0.07 5
13 0.13
- 5 17 0.25 0.82 5
19 0.16 5
20 0.09 0.20 0.18 0.18 5
27 0.10 5
33 0.48 1.42 5
34 0.38 5
35 0.29 0.94 6
2 0.06 6
7 0.13 6
12 0.06 6
14 0.11 6
17 0.07 6
18 0.08
.6 20 0.35 0.23 0.99
- 6.
32 0.23 6
37 0.41 0.10 1.04 6
40 0.26 6
45 0.24 7
7 0.13 0.06 7
13 0.12 7
14 0.13 0.11 7
18 0.13 7
19 0.13 0.19 7
20 0.12 0.11 7
21 0.31 0.09 0.07 1.08 7
22 0.32 7
23 0.25 DEG CHN 122 P2 124 P2 143 P2 103 P2 143 P2 144 P2 132 P2 120 110 128 P2 131 P2 151 P2 132 P2 139 P2 141 P2 115 P2 143 P2 127 P2 130 P2 110 86 129 P2 138 P2 131 P2 141 P2 140 P2 97 P2 142 P2 150 P2 134 P2 141 P2 148 P2 153 P2 146 P2 140 P2 135 P2 123 P2 146 P2 145 P2 116 146 141 P2 145 P2 142 P2 150 P2 144 P2 142 P2 135 P2 114 110 137 P2 142 P2 111 86 137 P2 133 P2 149 P2 142 P2 156 P2 90 P2 136 P2 144 P2 117 38 135 P2 140 P2 141 P2 115 2 138 P2 135 P2 113 P2 135 P2 138 P2 111 P2 141 P2 150 P2 142 P2 138 P2 143 P2 150 P2 139 P2 123 P2 152 P2 94 66 140 P2 144 P2 IND TWO TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD VOL TWD TWD TWD TWD TWD TWO TWD TWD VOL TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD
%TW LOCATION 10 011
-0.26 7
007
-0.29 6
013
+0.41 9
010
-0.26 16 013
+0.42 8
010
-0.28 21 010
-0.31 010
-0.54 8
011
-0.26 8
007
-0.33 5
007
+0.36 9
011
-0.28 10 011
+0.39 12 013
+0.41 6
003
-0.26 10 011
+0.37 6
010
-0.33 19 010
-0.31 011
-0.23 32 011
-0.28 6
011
+0.41 13 010
-0.26 6
001
-0.23 13 012
-0.31 6
010
-0.39 8
011
+0.36 8
011
-0.34 9
010
-0.34 10 013
+0.36 8
012
-0.39 6
011
+0.36 10 012
+0.37 7
- 011,
-0.34 5
010
-0.31 7
007
-0.31 12 011
+0.37 21 011
+0.37 011
+0.42 15 011
-0.37 6
008
+0.44 12 012
+0.29 11 013
+0.34 11 012
-0.39 9
011
-0.34 29 011
-0.34 011
-0.41 18 012
-0.36 21 010
-0.31 010
-0.46 6
007
-0.31 8
010
'0.26 7
010
-0.24 10 011
+0.37 5
010
+0.47 9
010
-0.34 26 012
-0.39 19 013
+0.34 012
-0.39 12 014
-0.42 26 011
-0.36 9
011
+0.26 011
-0.44 19 011
+0.39 18 011
-0.31 11 010
-0.24 6
010
+0.39 11 011
+0.37 8
010
-0.29 7
010
+0.36 8
013
+0.36 12 011
-0.39 17 011
+0.37 7
012
-0.39 7- 013
+0.34 24 011
-0.39 9
008
+0.42 8
011
+0.31 011
-0.47 17 012
-0.42 21 012
+0.32 EXT EXT UTIL 1
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE.UTE WAR LTE UTE WAR 010 0.10 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 011 011 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR
.LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 011 011 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 011 011 WAR LTE UTE WAR LTE UTE WAR 010 010 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 011 011 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE.
WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 011 011 WAR LTE UTE WAR LTE UTE WAR UTIL 2
CAL 100 100 52 100 100 52 54 53 54 52 52 52 52 52 100 6
100 52 54 51 52 0
52 54 100 100 4
42 40 42 52 52 52 52 54 54 52 5
42 4
42 2
42 41 0
42 40 40 40 8
40 3
54 54 53 52 54 53 42 40 4
42 5
42 40 42 42 42 41 52 54
.5.
54 53 100 54 9
38 5
38 4
42 4
40 40 40 42 42 4040" 42 6
42 3
42 41 40 42
- LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:11:40 Component: S/G B Page 2 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.82 7
27 0.35 7
32 0.09 7
34 0.33 7
39 0.25 7
43 0.11 7
44 0.20 7
49 0.13 7
51 0.18 8
8 0.08 8
9 0.13 0.07 8
12 0.17 8
13 0.10 8
15 0.23 8
16 0.24 8
17 0.14 8
19 0.06 8
23 0.15 8
26 0.15 8
27 0.06 0.07 8
35 0.30 1.67 8
36 0.12 8
40 0.22 0.24 8
42 0.08 8
46 0.19 8
50 0.10 8
51 0.08 8
53 0.09 8
57 0.15 9
4 0.08 9
9 0.06 0.09 9
11
- 0.11 9
13 1.41 0:08 0.16 0.66 0.12 9
15 0.08 9
16 0.10 9
17 0.12 9
18 0.09 9
23 0.14 9
25 0.16 9
47 0.33 1.27 9
48 0.12 9
50 0.11 9
51 0.46 1.90 9
52 0.18 9
57 0.12 10 10 0.19 10 13 0.17 0.24 10 14 2.35 0.69 10 16 0.17 10
'17 0.23 10 19 0.19 10 21 0.84 0.30 10 22 0.15 10 23 1.49' 0.41 10 29 0.10 0.06 10 31 0.07 0.19 10 33 0.09 0.16 10 52 0.22 10 54 0.22 11 2
0.06 11 9
0.13 DEG 119 141 148 140 140 146 143 143 134 123 126 15i 121 128 123 137 143 142
- 4149 146 138 156 142 108 147 147 143 132 144 143 148 123 142 105 140 143 148 107 131 138 132 141 146 133 125 142 140 143 145 114 137 142 134 98 140 140 147 136 141 101 138 150 138 141 115 141 147 101 137 150 144 150 148 152 141 143 141 131 154 CHN 122 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 30 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 122 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 2
P2 P2 30 P2 P2 P2 P2 P2 90 P2 P2 P2 P2 62 P2 P2 90 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD VOL TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD VOL TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW LOCATION 012
+0.29 18 014
-0.44 5
011
-0.36 17 011
+0.34 19 012
-0.39 9
010.
-0.31 11 010
-0.33 12 012
-0.34 15 OIl
-0.34 5
010
.+0.36 11 010'
-0.31 7
010
+0.42 10 010
+0.39 9
010
+0.31 18 010
+0.37 13 010
+0.44 12 010
+0.47 6
010
-0.37 12 013
+0.37 9
012
+0.23 6
011
-0.39 6
011
+0.31 22 011
-0.44 011
-0.60 7
012
+0.26 12 012
-0.41 13 013
+0.34 5
010
-0.38 11 012
-0.36 6
010
-0.33 7
010
-0.31 8
010
-0.31.
13 011
-0.34 5
003
-0.28 6
010
+0.26 8
011
+0.37 10 011
+0.34 012
+0.24 7
010
+0,.
21 13 012
-0.39 34 012
+/-0.31 10 013
+0.37 7
010
+0.16 6
010
+0.36 11 010
+0.31 6
010
+0.21 12 011
-0.42 13 012
+0.26 23 012
-0.45 012
-0.45 7
010
-0.36 7
011
-0.39 28 010
-0.36 010
-0.39 10 010
-0.36 11 010
-0.33 11 012
-0.36 14 012
+0.24 18 012
-0.42 012.
-0.47 28 012
-0:42 10 012
-0.39 18 012
+0.24 16 009
-0.42 009
-0.49 22 009
-0.39 9
013
+0.34 009
-0.44 26 009
-0.47 9
014
-0.50 6
014
+0.26 6
009
-0.44 15 009
+0.55 6
011
-0.44 9
013
-0.49 12 012
-0.41 12 012
-0.39 4
002
-0.23 11 012
-0.39 011
-0.36 EXT EXT UTIL 012 012 WAR LTE UTE WAR LTE DTE WAR LTE UTE WAR LTE UTE WAR LTE UTE
- WAR, LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR' LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR' LIE DIE WAR' LTEUTE WAR-012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE'UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 010 010 WAR
-LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 009 009 WAR LTE UTE WAR LTE UTE WAR 009 009 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 011 011 WAR 1
UTIL 2
CAL #
41 40 52 52 54 54 52 54 4
54 36 38 38 0
36 0
3838 36 38 38 38 36 38 38 54 53 4
52 52 52 52 4
52 52 54 54 54 36 38 0
38 0
38 37 38 38 38 38 38 36 38 36
- 0.
38 0
38 54 53 0
52 52 54 53 52
.54 36 38 0
38 35 36 36 38 38 37 38 8
36 37 38 38 38 38 0
38 52 52 52 52 36 0
38 35 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XBý 510XB 510XB 510XB "510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 11 12 1.29 112 110 VOL
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:40 Component: S/G BP Page 3 of 46 Service QUERY: u2sga.qry Induced Degradation ROW COL VOLTS 0.41
- 0.14 11 13 0.21 11 16 0.11 0.21 0.06 11 19 0.08 11 20 0.24 11 22 0.11 11 42 0.16 11 52 0.15 11 54 0.13 0.07 11 60 0.10 11 65 0.13 11 68 1.65 0.06 0.39 12 1
0.12 12
.2 0.07 0.10 12 10 0.20 0.05 12 11 0.22 12 13 0.24 12 14 0.24 12 18 0.16 12 20 0.23 12 30 0.19 0.11 0.13 0.12 12 34 0.24 12 39 0.21 0.14 0.08 12 52 0.15 12 64 0.09 12 65 0.15 12 71 0.06 0.04 13 2
0.06 13 9
0.34 13 12 0.15 13 1"3 0.19 13 14 0.09 13 17 0.26 0.16 13 18 0.10 13 23 2.73 0.26 0.12 0.58 0.13 0.16 13 30 0.08 13 33 0.15 13 48 0.08 13 56 0.12 13 61-0.09 0.16 13 63 0.07 0.10 13 65 0.07 13 67 0.12 14 1
0.09 14 2
0.07 14 4
0.11 14 10 0.34 14 12 0.20 0.25 14 13 0.26 0.07 14 15 0.19 14 16 0.24 0.18 14 i8 0.07 14 33 0.16 0.14 14 34 0.08 DEG 137 146 144 138 133 143 114 147 128 144 147 132 155 153 140 101 150 131 133 127 138 144 143 145 147 144 149 143 138 141 152 141 140 140 139 157 139 149 139 131 95 144 139 143 141 154 147 146 140 103 146 143 138 147 141 156 150 146 149 143 148 136 153 147 142 97 144 129 135 142 144 148 154 139 145 142 154 146 146 142 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 106 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 90 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD.
TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
-TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW 20 9
17 7
12 4
7 13 7
13 13 12 7
9 7
6 26 11 5
7 16 5
12 13 19 14 18 16 10 11 11 18 12 9
5 13 8
9 5
4 4
18 12 11 8
14 9
9 14 7
25 8
9 8
9 5
7 8
13 6
9 7
10 9
5 8
19 12 15 15 5
12 14 12 7-10 8
8 LOCATION 011
-0.39 011
+0.34 011
-0.37 012
-0.36 012
+0.29 013
+0.31 008
+0.00 012
-0.39 013
+0.29-012
-0.47 010
-0.39 010
-0.36 013
+0.31 011
+0.42 011
+0.36 012
-0.37 007
-0.31 012
-0.29 001
-0.18 007
-0.28 010
-0.26 012
-0.39 012
+0.29 012
-0.42 012
-0.44 012
+0.21 012
+0.24 011
-0.44 012
+0.16 013
+0.26 012
-0.50 013
-0.50 012
-0.47 012
-0.52.
013
-0.60 013
+0.21 012
+0.24 012
-0.37 010
-0.31.
006
-0.31 006
+0.70 007
-0.33 011
+0.31 011
-0.42 012
+0.18 012
- 0.23 012
-0.42 012
+0.21 014
-0.47 012
-0.49 011
-0.47 011
+0.26 012
-0.44 012
+0.21 013
+0.29 012
-0.50 012
-0.49 013
+0.21 013
+0.28 010
-0.39 012
-0.42 012
+0.24 012
-0.42 013
+0.29 010
-0.31 007
-0.31 007
+0.33 007
+0.36 011
+0.36 012
-0.44 012
+0.23 012
+0.23 012
-0.46 012
-0.44 012
-0.46 012
+0.21 012
+0.18 012
-0.52 012
+0.16 010
-0.47 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 DTE DTE
-UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE DTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTIL 1
WAR
'WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL # LEG 36 INLET 36 INLET 8
38 INLET 36 INLET 36 INLET 36 INLET 5 36 INLET 36 INLET 36 INLET 54 INLET 54 INLET 54 INLET "54 INLET 54 INLET 4
52 INLET 75 INLET 76 INLET 76 INLET 30 INLET 28 INLET 28 INLET 38 INLET 38 INLET 36 INLET 36 INLET 38 INLET 38 INLET 38 INLET 38 INLET 38 INLET 6
38 INLET 6
38 INLET
- 38 INLET 56 INLET 56 INLET 56 INLET 58 INLET 58 INLET 56 INLET 4
76 INLET 3
76 INLET 28 INLET 0
36 INLET 38 INLET 36 INLET 38 INLET 36 INLET 36 INLET 38 INLET 35 INLET 36 INLET 36 INLET 36 INLET 36 INLET 36 INLET 38 INLET 0-36 INLET 56 INLET 56 INLET 58 INLET 58 INLET 58 INLET 0
58 INLET 4
58 INLET 58 INLET 6
30 INLET 28 INLET 28 INLET 32 INLET 32 INLET 32 INLET 32 INLET 0
32 INLET
-. 32 INLET 32 INLET 32 INLET 1
38 INLET 0
36 INLET 0
36 INLET 38 INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XBý 510XB 510XB 510XB
.510XB 510XB 510XB 510XB 51 OXB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:40 Component:
S/G B Page 4 of 46 Service QUERY: u2sga.qry Induced Degradation ROW 14 14 15 15 15 15 15 15 15 15 15 15 15 15 15 15 16 16 16 16 16 16 16 16 16 16 16 16 16 16 16 17 17 17 17 17 17 17 17 17 17 17 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 18 19 19 19 COL 68 73 3
4 6
8 10 14 18 25 30 32 67 69 71 77 2
8 10 13 19 24 27 30 39 44 46 65 69 76 77 7
21 27 33 34 44 62 69 70 76 82 5
15 21 25 28 35 37 38 44 45 46 48 50 52 54 77 3
13 14 VOLTS 0.20 0.09 0.07 1.35 0.44 2.58 0.48 0.20 0.16 0.05 0.08 0.11 0.11 0.12 0.06 0.05 0.07 3.66 1.04 0.12 0.36 0.11 0.11 0.10 0.17 0.07 0.13 0.11 0.08 0.10 0.13 0.22 0.20 0.09 0.05 1.33 0.15 0.28 0.20 0.05 0.15 0.16 0.34 0.21 0.09 0.17 0.11 0.11 0.10 0.07 0.12 1.49 0.11 0.30 0.08 0.10 0.07 0.06 0.08 0.26 0.11 0.18 0.17 1.44 0.40 0.07 0.11 0.07 0.05 0.17 0.12 0.15 0.13 0.13 0.08 0.08 0.07 0.09 0.09 0.07 DEG 125 146 136 118 137 57 139 141 149 153 148 144 151 137 161 146 148 92 126 143 141 136 148 66 152 155 151 149 134 155 142 142 140 139 159 ill 146 144 138 144 139 146 140 135 121 141 145 136 125 155 146 50 153 135 147 145 143 132 151 137 153
.140 129 104 128 156 148 130 147 139 147 143 148 146 137 150 150 122 147 156 CHN P2 P2 P2 146 P2 Pl0 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 58 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 26 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P15 P2 P2' P2 P2' P2 P2 P2 P2 P2 P2 P2 158 P2 P2 P2
-P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD VOL TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW 16 9
7 23 29 16 13 5
8 7
7 7
5 4
7 42 10 19 10 7
7 14 7
11 7
5' 9
8 17 16 8
5 12 20 16 3
13 10 19 13 5
10 7
10 7
5 10 10 21 8
9 5
6 8
19 10 14 10 26 7
7 6
5 14 11 12 11 11 8
8 7
6 8
7 LOCATION 010
-0.33 007
+0.34 007
+0.34 011
+0.46 011
+0.41 011
+0.42 011
+0.42 011
+0.37 011
-0.39 011
-0.44 012
+0.21 014
-0.49 013
-0.47 013
+0.23 013
+0.21 012.
+0.21 007
-0.39 010
-0.36 010
-0.36 010
-0.33 011
-0.34 007
+0.36 012
+0.31 011
-0.28 012
-0.45 012
+0.21 012
-0.47 013
-0.47 012
+0.10 014
+0.21 014
-0.55 014
-0.63 012
-0.58 012
+0.13 009
-0.47 012
-0.47 011
+0.31 012
-0.47 011
-0.41 011
-0.36 011
-0.34 012
-0.41 012
+0.26 013
+0.34 012
+0.16 012
-0.52 012
-0.57 012
-0.52 011
-0.54 012
-0.51 011
-0.42 012
-0.49 011
-0.41 012
-0.42 011
-0.36 011
+0.39 007
+0.33 012
+0.21 013
.+0.29 014
-0.55 013
-0.45 013.
+0.26 014
-0.55 012
-0.52 012
-0.55 009
-0.52 009
+0.26 013
-+0.16 009
-0.44 012
-0.63 009
-0.44 010
-0.52 009
-0.44 012
+0.16 014
+0.13 014
-0.45 011
+0.42 012
-0.46 011
+0.24 012
-0.47 EXT LTE LTE LTE 011 LTE 011 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LiTE EXT UTE UTE UTE 011 UTE 011 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 1
UTIL 2-CAL # LEG 58 INLET 76 INLET 6
30 INLET 27 INLET 28 INLET 99 INLET 100 INLET 100 INLET 100 INLET 100 INLET 38 INLET 36 INLET 3
36 INLET 0
36 INLET 38 INLET 38 INLET 58 INLET 57 INLET LAR 58 INLET 58 INLET 74 INLET 30 INLET 6
32 INLET 6
32 INLET 4
100 INLET 38 INLET 7
38 INLET 36 INLET 36 INLET 38 INLET 36 INLET 38 INLET.
64 INLET 64 INLET 64 INLETý 57 INLET 58 INLET 0
58 INLET 58 INLET 74 INLET 76 INLET 28 INLET 28 INLET 28 INLET 0
36 INLET 36 INLET 36 INLET 0
38 INLET.
62 INLET 62 INLET 68 INLET 99 INLET 100 INLET 100 INLET 76 INLET 0
76 INLET' 28 INLET 30 INLET
.4 30, INLET 38 INLET 0
38 INLET
.0 38 INLET 0
36 INLET 37 INLET 38 INLET 38 INLET
.0 36 INLET 68 INLET 68 INLET 0
68 INLET 68 INLET 68 INLET 68 INLET 68 INLET 68 INLET 76 INLET 0
30 INLET 28 INLET 30 INLET 30 INLET PROBE 510XB 510XB 510XB 510XP 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB.
510XB
ý510XB 510XE 510XB 510XB 510XE 510XB 510XB 510XP 510XB 510XB 51OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:40 Component: S/G B Page 5 of 46 Service QUERY: u2sga.qry Induced Degradation ROW COL VOLTS 0.07 0.07 19 16 0.07 0.15 0.10 19 26 0.09 0.10 19 27 0.19 19 30 0.19 19 44
'0.08 19 46 0.15 0.06 19 50 0.09 19 51 0.07 19 52 0.08 19 66 0.07 19 73 0.21 19 74 0.11 0.15 0.37 1.38 3.88 1.18 19 77 0.05 20 2
0.11 20 8
0.12 20 14 0.08 20 20 0.07 20 25 0.19 20 26 0.09 20 31 0.12 20 38 0.08 20 43 0.09 20 46 0.10 20 52 0.06 20 54 0.06 0.07 20 57 0.14 20 60 0.06 20 61 0.23 0.07 20 65 0.10 0.07 20 67 0.10 20 72 0.13 20 74 0.12 20 75 0.09 20 76
- 0. 71 2.48 21 I
0.06 21 3
0.05 21 10 0.06 21 13 0.09 21 14 0.16 0.07.
21 16
- 0.12 21 19 0.25 21 39 0.20 0.20 21 47
'.0.09 21 48 0.11 21 49 0.07 21 51 0.07 21 55 0.15 21 75 0.14 21 76 0.05 21 78 0.24 21 79 2.90 0.67 0.16 21 80 0.20 21 86 0.08 0.16 22 9
0.18 22 14 0.16 0.07 22 31 0.13 0.05 22 32 0.06 22 34 0.05 DEG 159 158 154 150 147 142 116 136
'131 132 128 155 147 140 145 148 139 152 147 137 123 90 70 148 129 137 154 126 129 103 133 148 129 141 147 146 136 149 90 138 98 136 156 137 143 140 139 129 72 138 139 122 149 146 150 150 140 136 147 94 121 147 153 126 150 141 148 94 131 152 141 144 81 152 152 150 137 146 126 94 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 82 P27 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P9 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 130 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD
-TWD TWD TWD TWD TWD TWD TWD
%TW 7
7 7
13 9
8 9
11 16 7
12 6
8 6
7 7
16 10 12 24 47 3
10 11 6
5 16 6
11 5
8 8
6 6
7 12 6
18 7
8 6
8 11 10 8
35 6
5 4
6 13 7
11 15 ii 12 8
10 7
6 12 8
5 19 28 10 16 8
13 11 13 7
12 5
5 3
LOCATION 013
-0.45 013-
+0.29 012
-0.50 014
-0.53 014
+0.21 013
-0.52 013
+0.24 009
+0.29 014
-0.58 009
-0.42 012
-0.63 009
-0.42 009
-0.44 010
+0.18 009
-0.47 010
-0.44 010
-0.39 013
-0.42 013
+0.29 014
-0.52 010
-0.39 010
-0.36 014
-0.54 010
-0.39 007
+0.39 013
+0.34 011
-0.46 013
+0.28 014
-0.58 014
-0.61 012
-0.55 009
+0.28 009
+0.28 009
-0.47 009
-0.47 008
+0.36 011
+0.16 012
-0.58 010
+0.16 012
-0.55 012
+0.18 014
+0.16 009
-0.41 012
-0.50 012
-0.44 011
+0.26 011
+0.23 010
-0.36 010
-0.38 007
-0.34 011
-0.39 009
-0:44 012
+0.23 011
-0.39 011
+0.24 012
-0.50 012
+0.18 012
-0.57 012
+0.13 012.
-0.63 012
-0.66 009
-0.47 009
-0.47 012
-0.58 011
-0.46.
008
+0.39 012
-0.42 010
-0.42 010
-0.37 012
-0.42 014
-0.53 010
-0.34 010
+0.68 012
-0.39 012
-0.47 013
-0.50 012
-0.58 012
+0.13 009
-0.51 009
-0.47 EXT EXT LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 010 010 014 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 010 010 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 010 010 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR
- WAR, WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 1
UTIL 2
CAL #
30 30 30 30 30 38 38 36 38 68 68 68
.68 0'
68 68 4
68 2
68 68 68 68 LAR 68 67 67 74 30 6
30 28 0
28 30 28 38 36
'0 38 68 2
68 3
68 3
68 3
68 4
68 68 3
68 68 3
68
.0 68 68 68 4
68 68 67 4
26 26 28 28 0
30 0
30 30 28 36 36 68 68 68 68 5
68 70 2
72 72 73 74 2
74 76 76
'10 76 24 30 30 7
30 4
30 28 36 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET
'INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB.
510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB'
.510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
- 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510 XB
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:11:40 Component:
S/G B Page 6 of 46 Component: S/C B Page 6 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.05 22 37 0.15 22 48 0.09 22 75 0.09 22 78 0.10 0.24 22
.84 0.18 22 89 0.16 23 2
0.12 23 14 0.17 23 15 0.15 23 18 0.08 0.18 23 19 0.11.
23 21 0.14 23 31 0.07 23 48 0.08 0.05 23 54 0.11 23 56 0.08 23 60 0.15 23 69 0.07 0.06 23 71 0.20 23 74 0.27 23 75 0.05.
23 85 0.12 0.05 24 3
0.08 0.08 24 20 0.12 24
- 22.
0.10 24 31 0.08 24 46 0.15 24 49 0.08 24 50 0.06 24 80 0.08 24 81 2.26 0.14 0.57 0.31 24 83 0.14 24 84 0.10 24 88 0.19 25 9
0.11 25 17 0.18 25 20 0.14 0.12 25 24 0.09 25 44 0.05 25 70o 0.05 25 72 0.05 25 84 0.09 25 96 0.08 26 2
0.12 0.17 26 7
0.08 26
'14 0.12
- 26 18 0.19 0.22 26 23 0.27 26 28 0.07 26 45 0.11 26 49 0.09
.26 51 0.06 26 56 0.10 26 61 0.11 26 80
-0.24 26 81 0.17 27 12 0.06 27 28 0.16 27 38 0.10 27 44 0.11 27 89 1.18 0.29 27 92 0.08 0.09 28 17 0.31 28 37 0.07 28 42 0.09 DEG 155 145 152 101 149 148 139 143 137 150 126 148 138 132 137 147 153 141 152 128 141 144 148 143 130 165 154 149 134 157 144 142 141 140 130 154 146 94 149 135 147 150 139 148 146 137 126 148 155 158 43 158 142 149 132 118 149 148 150 139 134 102 146 138 158 152 149 144 145 151 137 147 145 106 135 152 154 133 156 143 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 150 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 74 P2 P2 P2 P2 P2 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD
%TW LOCATION 3
013
+0.16 13 012
+0.08
- 8. 009
-0.47 9
014
-0.60 6
007
-0.43 13 012
-0.46 11 010
-0.34
.14 010
-0.34 8
012
-0.36 14 011
+0*.26 10 012
-0.51 8
012
+0.18 15 012
-0.50 7
012
-0.51 9
012
-0.54 5
010
+0.20 5
013
+0.10 3
013
-0.62 7
'009
-0.47 5
009
-0.47 9
012
-0.62 7
010
+0.24 6
010
-0.42' 16 012
-0.55 15 014
-0.62 5
012
-0.53 8
012
-0.42 3
613
+0.29 7
012
-0.34 7
013
-0.37 11 012
-0.52 9
011
+0.13 6
009
+0.23 10 009
-0.53 5
009
+0.23 4
009
-0.49 8
013
+0.21 011
-0.52 9
010
-0.39 25 011
-0.49 17 012
-0.50 12 012
-0.45 6
009
-0.37 11 014
-0'.45 7
012
-0.39 11 012
+0.18 12 013
-0.53 11 013
+0.21 9
009
-0.46 4
010
+0.15 5
014
+0.03 5
010
+0.16 8
012
-0.50 7
011
+0.39 8
012
-0.33 11 010
+0.67 7
013
+0.32 8
012
-0.44 16 012
-0.50
- 17. 012
+0.18 16 012
+0.15 7
009
+0.23 7
009
-0.51 6
009
-0.51 4
009
-0.47 6
011
-0.03 7
013
+0.08 19 012.
-0.53 10 012
-0.49
- 4. 012
+0.23 10 012
+0.10 7
009
-0.48 8
009
-0.53 011
-0.42 21 011
-0.42 5
009
-0.39 6
012
-0.44 17 012
-0.47 5
007
+0.18 6
009
-0.56 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 011 LTE LTE LTE LTE LTE
'LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 011 LTE LTE LTE LTE LTE
- LTE EXT UTIL UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE..WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 011 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE -WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 011 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 1
UTIL 2
CAL 36 38 72 72 70 0
70 5
74 76 24 30 28 30 0
.30 28 28 5
28 4
597 4
597 70 70 6
597 3
72 2
72 6
72 70 72 74 74 26 3
26 0
30 0
30 3
28 28 3
597 70 4
72 73 74 74 74 0
76 74 74 24 28 30 30
.30 28 0
72 2
72 76 5
76 24 24 4
26 6
24 30 30 28 0
30 28 3
575 70 70 5
597 72 0
70 24 28 28 28 75 76 74 74 24 28 5
575
- LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET
'INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510UL 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXB 510XB 510XB 510UL 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510UL
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:40 Component: S/G B Page 7 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 28 46 0.08 28
'47 0.10 28 48 0.14 28 53 0.07 28 55 0.10 28 83 0.19 28 101 0.08 29 1
0.15 0.09 29 7
0.07 29 8
0.11 29 11 0.30 1.59 29 17 0.10 29 46 0.09 29 47 0.09 29 54 0.08 29 83 0.07 29 86 0.23 29 96 0.08 29 104 0.08 0.21 30 1
0.13 30 8
0.23 0.13 30 9
0.13 30 27 0.12 0.21 30 54 0.08 30 55 0.10 30 91 0.22 30 102 1.70 0.42 30 104 0.25 30 105 0.14 31 1
0.08 31 6
0.10 31 10 0.17 0.07 31 12 0.10 0.21 31 13 0.09 31 22 0.21 0.10 31 26 0.16 31 43 0.10 31 44 0.19 31 51 0.11 31 86 0.13 0.06 0.05 31 87 0;16 0.06 31 94 0.14 31 96
.0.10 31 97 0.14 32 14 0.19 32 16 0.11 0.07 32 32 0.09 32 38 0.08 0.14 32 94 0.37 32 101 0.08 32 105 0.10 0.09 33 8
0.14 33 12 0.21 33 20 0.16 33 31 0.10 33 50 0.10 33 56 0.08 33 91 0.08 33 100 0.07 33 101 1.46 0.29 33 102 0.13 34 4
0.07 34 5
0.07 0.24 DEG CHN 153 P2 121 P2 138 P2 159 P2 146 P2 143 P2 124 P2 143 P2 136 P2 121 P2 141 P2 143 P2 95 P11 159 P2 155 P2 148 P2 149 P2 157 P2 135 P2 146 P2 113 P2 143 P2 149 P2 133 P2 151 P2 153 P2 146 P2 131 P2 149 P2 141 P2 147 P2 91 102 132 P2 138 P2 145 P2 131-P2 148 P2 138 P2 151 P2 151 P2 145 P2
.162 P2 143 P2 150 P2 95 P2 134 P2 152 P2 136 P2 139 P2 31 P2 137 P2 124 P2 147 P2 147 P2 137 P2 149 P2 149 P2 147 P2 138 P2 151 P2 77 P2 109 P2 139 P2 152 P2 140 P2 150 P2 138 P2 144 P2 144 P2 158 P2 129 P2 144 P2 153 P2 115 P2 105 82 133 P2 149 P2 153 P2 111 P2 141 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
ýTWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD
'TWD TWD TWD TWD
%TW 6
7 10 4
6 16 7
12 8
6 8
21 9
6 6
6 7
13 5
8 17 11 17 11 8
8 13 5
6 17 21 14 12 7
7 11 5
6 13 8
17 10 10 7
12 7
8 4
3 94 12 9
9 12 8
5 6-6 11 19 7
9 8
9 13 10 7
8 5
7 4
21 8
6 5
14 LOCATION 009
-0.51 009
-0.53 009
-0.51 009
-0.52 009
-0.52 012
-0.56 009
-0.32 010
-0.28 011
-0.29 010
-0.34 013
+0.34 013
+0.29 013
+0.29 010
+0.57 009
-0.54 009
-0.54 009
-0.47 010
+0.21 012
-0.52 011
+0.34 002
-0.21 011
-0.26 012
-0.31 011
+0.29 010
-0.34 012
-0.42 012
+0.10 012
-0.61 009
-0.51 009
-0.52 012
-0.50 010
-0.39 010
-0.31 011
-0.26 011
-0.26 007
-0.34 013
+0.31 012
+0.29 012
-0.39 012
-0.44 012
+0.21 012
-0.45.
012
-0.58 012
+0.16 012
-0.59 009
-0.53 009
-0.54 007
+0.10 012
-0.57 012
+0.68 012
+0.18 013
-0.57 011
.+0.13 012
-0.53 014
+0.24 014
-0.50 012
-0.49 012
-0.49 012
+0.18 009
+0.15 012
-0.03 012
-0.72 012
-0.52 011
+0.34 011
-0.29 011
+0.45 012
-0.41 012
+0.18 014
+0.08 012
+0.03*
008
+0.23 009
-0.49 010
+0.18 007
-0.36 011
-0.42 011
-0.39 014
+0.26 013
-0.39 007
+0.31 012
-0.36 EXT EXT LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 013 013 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 010 010 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE.UTE LTE. UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE.
LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE
- LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 011 011 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR
-WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL #
4 575 28 5
575 70 70 72 76 26 26 0
26 24 26 25 5
26 28 4
575 6
599 0
72 74 74 76 76 26 26 6
'26 24 28 0
28 52 6
597 76 73 74 74
'76 4
26 24 24 0
24 24 24 0
26 30 30 28 28 6
575 28 5
70 4
70 0
70 74 74 76 76 74 24 24 24 28 0
577 0
577 74 76 76 76 0
24 24 24 4
575 5
577 4
597 4
76 74 75 76 74 5
26 24 24 LEG PROBE INLET 51OUL INLET 510XB INLET 51OUL INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 51OXB INLET 510XB INLET 510XP INLET 510XB INLET 51OXB INLET 510UL INLET 510UL INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB' INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB.
INLET 510XB INLET 510UL INLET 510XB INLET 510XP INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 51OXB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 51OXB INLET 510XB INLET 510XB INLET 510XB INLET 510UL INLET.
510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET.
51OUL INLET 510UL INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510UL INLET 510UL INLET 510UL INLET 510XB INLET 510XB INLET 510XP INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 51"0XB
AREVA NP Inc Customer Name: 0NS2 Repl 01/20/09 02:11:40 Component: S/G B Page 8 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 34 10 0.38 0.15 0.09 1.75 34 17 0.14 34 53 0.14 34 84 0.13 34 88 0.08 34 103 0.93 0.30 0.09 35 5
0.13 35 9
0.13 35 16 0.13 35 18 0.11 35 27 0.14 35 29 0.11 35 51 0.13 35 103 0.10 35 108 0.15 0.15 35 110 0.10 36 1
0.23 0.22 0.07 36 4
0.17 36 8
0.09 0.13 36 9
0.09 36 11 0.17 36 12 0.12 0.10 36 19 0.09 36 34 0.18 36 54 0.08 36 85 0.07 36 103 1'.47 0.30 36 104 0.15 36 105 0.09 36 112 0.09 36 113 1.05 0.14 0.47 37 6
0.11 37 11 0.14 37 13 0.34 1.66 37 30 0.08 37 94 0.22 37 106 6.13 37 112 0.21 0.23 37 113
.0.16 0.24 37 114 0.92 0.19 0.18 0.37 38
ý7 0.07 38 12 0.18 0.28 0.08 38 13 0.14 0.11 38 14 1.92 0.31 0.37 0.08 38 22 0.08 38 37 0.08 38 52 0.11 38 92 0.21 38 110 0.11 38 112 0.19 38 114 0.11 38 115 0.71 0.21 0.27 39 2
0.14 DEG 140 153 137 99 146 144 136 158 123
'39 129 146 140 121 132 143 114 151 148 152 147 133 121 135 142 147 83 146 134 135 150 141 131 131 117 134 ill 143 150-142 150 117 145 136 148 150 138 100 141 135 146 143 133 144 141 117 139 143
.138 144 147 140 143 146 157 68 142 136 145 156 155 148 141 149 146 140 118 145 143 125 CHN P2 P2 P2 P12 P2 P2 P2 P2 2
P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 50 P2 P2 P2 P2 110 P2 P2 P2 P2 P2 P12 P2 P2 P2 P2 P2 P2 P2 86 P2 P2 P2 P2 P2 P2 P2 P2 P2
.P27 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 86 P2 P2 P2 IND TWD TWD TWD VOL TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD "TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD
%TW 25 12 8
9 8
8 5
22 9
11 11 8
7 9.
8 9
6 13 13 9
17 17 6
14 8
11 6
11 10 9
6 11 6
7 229 "
8 6
12 29 8
i2 23 6
13 8
12 13 14 19 16 15 25 6
11 16 5
11 9
17 20 6
5 8
8 12 7
11 7
17 20 9
LOCATION 012
+0.26 013
-0.52 011
+0.29 012
+0.24 012
+0.16 009
-0.51 012
-0.65 007
-0.52 009
-0.31 009
-0.39 010
-0.34 011
+0.29 010
-0.39 011
+0.21 012
-0.57 012
+0.08 012
-0.62 007
+0.13 012
-0.47 011
+0.39 012
-0.39 011
-0.29 010
+0.68 011
-0.29 012
-0.31 012
+0.32 013
+0.21 012
-0.37 010
-0.36 012
+0.23 012
-0.45
.011
-0.39 012
+0.18 009
+0.13 009
-0.53 010
+0.13 012
-0.45 012
-0.53 012
-0.50 009
-0.37 011
+0.47 011
+0.52 011
-0.26 011
+0.47 012
-0.36 011
+0.32 012
+0.24 012
+0.18 013
+0.03 012
-0.60 009
-0.39 011
-0.26 011
+0.44 011
-0.26 011
+0.47 011
+0.55 007
-0.29 011
-0.26 011
+0.47 012
+0.29 012
-0.44 012
+0.23 011
-0.49 012
+0.21 012
-0.47 013
+0.21 012
-0.49 013
+0.21 009
-0.44 010
+0.15 009.
+0.08 007
+0.15 012
-0.65 012
-0.44 011
+0.42 007
-0.34 011
+0.55 011
-0.26 011
+0.47 011
-0.31 EXT EXTE UTIL LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 009 009 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE"UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE-UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE -WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 011 011 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTEUTE WAR LTE UTE WAR LTE UTE WAR 011 011 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR.
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 013 013 WAR LTE UTE WAR LTE UTE
'WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 011 011 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 1
UTIL 2
CAL #
26 7
26 0
26 25 24 4
579 70 74 75 76 76 5
26 26 0
24 24 28 28 28 74 76 76 76 26 26 26 26 5
26 0
26 24 24 26 6
26 24 28 28 0
609 75 76 74 76 74 75 76 76
.0 24 26 26 25 28 74 74 74 74 76 76 75 76 76 76 22.
2Q 20 3
20 0
22 22 19 20 20 20 4
20 4
581 28 74 74 74 74 75 76 76 20 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET
-INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XP 510XB 51OUL 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XP 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB
,510XB 510XB 510XP 510XB 510XB 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510KB 510XP 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:40 Component: S/G B Page 9 of 46 Service QUERY: u2sga.qry Induced Degradation ROW 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 39 40 40 40 40 40 40 40 40 40 40 41 41 41 41 41 41
.41 41 41 41 41 42 42 42 42 42 42 42 42
.42 42 42 42 43 43 43 43 43 COL 5
6 8
10 12 21 22 24 34 37 39 50 59 109 113 116 1
10 11 14 15 99 100 102 107 115 7
8 14 20 29 46 54 106 109 114 115 6
7.
8 14 15 16 26-31 105 109 113 115 2
12
.19 49 108 VOLTS 0.08 0.15 0.10 0.14 0.11 0.06 0.13 0.13 0.09 0.11 0.09 0.10.
0.07 0.09 0.08 0.08 0.05 0.12 0.05 0.18 0.19 0.83 0.31-0.11 0.14 0.11 0.12 0.10 0.14 0.10 0.11 0.10 0.18 0.09 0.11 0.17 0.17 0.12 0.11 0.11 0.13 0.20 0.08 0.09 0.07 0.05 2.12 0.08 0.46 0.30 0.10 0.20 0.07 0.07 0.11 0.14 0.12 0.14 0.17 0.07 0.24 0.07 0.07 0.15 0.06 0.10 1.92 0.13 0.30 0.09 0.06 0.12 0.09 0.11 0.11 0.38 1.19 0.06 0.12 0.08 DEG 155 145 141 145 157 144 147 145 156 130 114 130 142 151 143 130 106 154 137 150 150 113 138 148 146 139 142 151 152 145 146 133 142 131 142 144 147 144 149 137 92 150
.90 149 132 75 96 143 135 142 146 140 153 152 134 144 142 149 138 139 127 144 136 146 155 144 97 134 143 150 158 144 139 146 139 132 89.
103 148 153 CHN IND %TW P2 TWD 7 P2 TWD 12 P2 TWD 7 P2 TWD 9 P2 TWD 7 P2 TWD 4 P2 TWD 8 P2 TWD 9 P2 TWD 6 P2 TWD 9 P2 TWD 6 P2 TWD 6 P2 TWD 6 P2 TWD 7 P2 TWD 8
P2 TWD 6 P2 TWD 4 P2 TWD 10 P2 TWD 3 P2 TWD 14 P2 TWD 15 110 VOL P2 TWD 22 P2 TWD9 P2 TWD 12 P2. TWD 10 P2 TWD 11 P2 TWD 7 P2 TWD 12 P2 TWD 9 P2 TWD 7 P2 TWD 9 P2 TWD 11 P2 TWD 6 P2 TWD 7 P2 TWD 14 P2 TWD 14 P2 TWD 11 P2 TWD 9 P2 TWD 10 P2 TWD 8 P2 TWD 12 P2 TWD 6 P2 TWD 6 P2 TWD 5 P2 TWD 4 78 VOL P2 TWD 8 P2 TWD 28 P2 TWD 16 P2' TWD *9 P2 TWD 12 P2 TWD 5 P2 TWO 5' P2 TWD 9 P2 TWD 12 P2 TWD 8 P2 TWD 9 P2 TWD 11 P2 TWD P2 TWD 18 P2 TWD 5 P2 TWD 5 P2 TWD 10 P2 TWD 4 P2 TWD 9 82 VOL P2 TWD 11 P2 TWD 21 P2 TWD 8 P2 TWD 6 P2 TWD 10 P2 TWD 6 P2 TWD 7 P2 TWD 7 P2 TWD 25 P16 VOL P2 TWD 4 P2 TWD 10 P2 TWD 8 LOCATION 012
-0.37 012
+0.29 012
-0.36 013
+0.34 014
-0.49 007
+0.31 013
+0.26 011
-0.41 012
-0.44 012
+0.13 012
-0.59 012
+0.10 010
+0.16 012
+0.08 009
+0.10 007
+0.15 007
+0.13 007
+0.13 007
+0.08
.012
-0.50 011
+0.42 011
+0.52 011
+0.47 007
+0.42 013
-0.37 010
-0.26 010
-0.36 012
-0.44 012
-0.50 013
+0.21 012
-0.52 013
-0.58.
011
-0.55 011
+0.16 013
+0.16 009
-0.42 011
-0.29 011
+0.42 013
-0.47 013
+0.29 010
-0.39 012
-0.49 011 O
-0.59 012
+0.03 008
+0.23 007.
+0.10 012
-0.58.
009
-0.39 012
-0.53 012
-0.47 011
+0.29 011
-0.29 011
+0.31 013
-0.44 013
-0.47 014
-0.48' 013
+0.31 010
-0.39 014
-0.57 014
+0.16 012
-0.53 010
+0.21 011
+0.08 012
-0.67 012
+0.00 013
+0.18 012
-0.52 010
-0.37 012
-0.50 011
+0.31 012
-0.45 011
-0.29 006
-0.28 012
-0.36 013
+0.21 011
+0.13 011
+0.08 007
+0.15 009
-0.42 011
+0.29 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 011 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE.
LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT
==TE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE
- UTE, UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE 011 UTE UTE OTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR*
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL #
22 22 5
20 20 20 3
20 20.
3 20 5
20 22 6
20 5
20 3
571 5
571 3
581 28 28 4
581 70 84 84 83 84 22
- 22 4
22 22 6
20 22 22 6
20 84 82 0
82 82 84 84 84 22 22 6
20 20 5
20 28 28 28 83 84 84 82 0
84 82 0
20 4
20 22 22 20 4
20 20
.20.
22
.4 20 28 28 28 0
84 83 84 84-4 84
.0 84 84 20 20 20 22 21 28 84 0
84 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL" 51OUL 51OUL 510XB 510XB 510UL 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:40 Component: S/G B Page 10 of 46 Service QUERY: u2sga.qry Induced Degradation ROW COL VOLTS 43 111 0.14 0.10 43 116 1.00 0.27 44 7
0.09 0.12 0.12 44 8
0.17 0.11 44 9
0.13 44 12 0.16 0.10 44 14 0.11 44 15 0.16 44 16 0.19
-44 18 0.13 44 27 0.09 44 110 0.09 44 111 0.08 45 5
0.10 45 7
0.31 0.15 0.09 1.29 45 9
0.10 0.13 45 13 0.16 45 16 0.23 0.08 45 19 0.29 1.09 45 24 0.10 45 103 0.08 45 110 0.08 45 112 0.12 45 118 0.19 45 119 0.20 46 2
0.08 46 3
0.12 46 5
0.16 46 9
0.21 46 15 0.20 0.09 0.19 46 18 0.07 46 20 0.07 46-94.
0;10 46 95 0.09 46 11 0.09 47 3
0.13 47 8
0.19 0.07 47 10 0.11 47 19 0.14 47 23 0.07 47 50 0.09 47 97 0.07 0.11 47 99 0.07 47 103 0.13 47 122 0.11 48 3
0.14 48 4
0.10 48 6
0.21 0.09 48 7
0.22 48 8
0.14 48 9
0.13 0.19 48 18 0.08 48 20 0.15 0.14 48 22 0.07 48 99 0.05 48 101- 0.06 48 112 0.08 48 114 0.07 48 115 0.11 48 123 0.08 49 1
0.10 DEG 138 134 89 140 149 148 136 141 144 152 116 135 150
-139 140 146 101 94 153 154 144 145 156 85 135 141 137 142 139 128 86 157 136 134 142 142 144 146 148 143 138 149 148 141 139 149 126 127 137 140 148 153 146 138 88 125 151 139 136 137 142 140 141 141 147 149 143 143 146 125 135 136 120 100 140
'45 144 155 142 141 CHN IND P2 TWD P2 TWD 54 VOL P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2
- TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P18 VOL P2 TWD P2 TWD P2 TWD P2 TwD P2 TWD P2 TWD P19 VOL P2-TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2-TwO P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD
%TW 9
6 20 8
10 10 11 7
Ii 10 7
7 13 12 8
9 6
7-8 21 13 8
9 11 13 14 5
20 7
7 5
7 12 16 5
10 13 16 15 8
15 5
5 7
8 8
8 15 6
9 9
6 6
6 10 6
- 11i, 10 12 7
13 6
17 9
11 15 6
9 9
5 5
5 7
7 7
7 9
LOCATION 010
-0.34 012
-0.49 011
-0.34 011
-0.31 012
-0.42 012
+0.26 011
+0.32 014
-0.52 013
-0.52 012
-0.42 613
-0.57 014
+0.18 011
-0.49 011
+0.24 012
-0.54 014
-0.65 012
-0.61 009
-0.36 012
-0.50 012
-0.37 014
-0.50 014
+0.24 013
"+0.29',
014
-0.50 010
+0.00 013
+0.29 013
-0.58 012
-0.49 012
+0.16 014
-0.64 014
-0.64 01A
-0.70 010
+0.24 009
-0.39 014
-0.52 011
-0.34 012
-0.39 007
+0.39 012
-0.34 013
+0.34 010
+0.00 012
-0.55 012
+0.13 013
+0.19 012
+0.I0 011
+0.10 011
+0.00 007
-0.55 011
+0.29 011
-0.34 014
-0.50 012
-0.48 013
-0.53 010
+0.21 012
-0.67 009
-0.59 007
-0.52 014
-0.03 007
-0.52 013
-0.61 011
-0.29 011
-0.34 011
-0.34 014
-0.47 013
-0.44.
012
-0.42 010
-0.39 013
-0150 014
-0.53 012
-0.60 013
-0.65 012
-0.57 010
+0.13 007
-0.55 007
+0.16 011
+0.24 012
+0.29 011
-0.41 007
-0.29 006
-0.29 EXT LTE tTE 011 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE
.LTE LTE LTE LTE LTE LTE LTE LTE 014 LTE LTE LTE LTE LTE LTE 014 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LIE EXT UTE UTE 011 UTE UTE UTE DTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 UTE UTE UTE UTE UTE UTE 014 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR
'WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL #
82 0 ~
82 83 84 22 22 0
22 20 6
20 22 2020 4
20 22 20 0
20 30 0
82 0
84 22 22 6
22 5
22 21 22 4
22 22 2o 20 22 21 20 0
84 0
82 82 82-84 20 22 22 22 22 22 22 20 20 82 2
639 84 20 22 0
22 22 20 0
-567 28 3
639 3
639 3
639 6
84 92 22 20 20 5
20 22 20 22 22 6
20 20 4
20 5
-20 0
639 3
639 0
84 84
- 0.
82 92 0
100 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET -
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510UL 51OXB 510UL 51OUL 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510UL 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:11:40 Component: S/G B Page 11 of 46 Service QUERY: u2sga.qry Induced Degradation ROW 49
-49 49 49 49 49 49 49 49 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 50 51:
51 51 51 51 51 51 52 52 52 52 52 52 52 52 52 52 52 52 52 52 53 53 53 53 53 53 53 53 53 54 54 54 5454 COL VOLTS 9
0.12 24 0.09 39 0.05 110 0.09 11 0.10 112 0.14 114 0.25 115 0.13 116 0.21 3
0.28 5
0.12 7
0.15 8
0.16 9
1.97 0.36 0.54 10 0.25 11 0.21 14 0.14 0.16 17 0.10 50 0.05 52 0.06 53 0.09 92 0.07 106 0.17 0.13 116 0.18 119 0.22 5
0.13 0.40 1.33 8
0.16.
10 0.33 102 0.07 117 0.08 0.15 118 0.10 0.10i 122 0.10 1
0.12 3
0.12 4
0.57 0.14 1.85 5,
0.33 0.08
- 7.
0.08 8
0.07 0.15 0.08 9
0.31 0.09 108 0.13
.110 0.13 li4 0.23 117 0.09 118 0.16 119 0.08 0.11 121 0.24 3
0.10 7
0.13 9
0.06 0.07
- 29.
0.10 112 0.14 114 0.14 117 0.15 119 0.29 122 0.07 1
0.13 0.17 0.08 2
0.18 4
0.14 0.12 7
0.21 8
0.11 0.22 DEG 149 151 103 152 159 150 142.
142 146 142 147 141 151 59 137 133 145 143 129 152 145 47 101 143 145 126 117 151 149 147 140 78 147 138 131 152 148 134 140 146 133 140 136 145 80 140 151 157.
143 138 157 140 127 133 150 142 154 149 153 147 140 140 143 146 150 142 136 147 144 146 148 143 130 107 148 140 149 142 127 142 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P5 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P22 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P22 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2P2 IND %TI TWD 10 TWD 6 TWD 3 TWD 6 TWD 9 TWD 9 TWD 14 TWD 11 TWD 12 TWD 16 TWD 8 TWD 9 TWD 13 VOL TWD 19 TWD 25 TWD 18 TWD 13 TWD 11 TWD 13 TWD 7 TWD 3 TWD 4 TWD 6 TWD 4 TWD 14 TWD 11 TWD 14 TWD 13 TWD 11 TWD 25 VOL TWD 10 TWD 18 TWD 6 TWD 6 TWD 10 TWD 9 TWD 9 TWD 9 TWD 10 TWD 8 TWD 31 TWD 12 VOL TWD 18 TWD 5 TWD 5 TWD 6 TWD 12 TWD 7 TWD 17 TWD 6 TWD 8 TWD 8 TWD 14 TWD 8 TWD 10 TWD 7 TWD 10 TWD 18 TWD 6 TWD 8 TWD 4 TWD 5*
TWD 6 TWD 12 TWD 12 TWD 10 TWD 16 TWD 6 TWD 11 TWD 14 TWD 7 TWD 10 TWD 11 TWD 10 TWD 13 TWD 10 TWD 17 W LOCATION 012
-0.42 012
+0.03 007
+0.20 014
+0.13 010
+0.58 012
-0.55 012
-0.52 012
+0.29 011
-0.42 012
-0.:36 010
-0.34 010
-0.36 012
-0.42 014
-0.55 013
+0.29 014
-0.55 012
-0.47 012
+0.21 013
-0.55 014
+0.16 013
-0.63 007
+0.15 007
+0.13 009
-0.61 007
-0.52 014
-0.60 013
-0.63 012
-0.47 012
-0.44 010
-0.34 012
-0.40 012
-0.37 011
+0;29 012
-0.44 008
+0.26 011
-0.44 012
-0.47 010
-0.37 011
+0.29 011
-0.34 007
-0.31 011
+0.34 012
-0.37 013
-0.40 012
-0.37 012
-0.39 013
-0.42 012
-0.42 010
-0.39 011
+0.26 012
-0.45 014
-0.52 013
-0.57 010
+0.23 014
+0.03 012
-0.52 012
-0.47 012
-0.47 012
-- 0.45 011
+0.29.
012
-0.39 011
-0.34 012
-0.42 011
+0.26 012
-0.47 013
+0.03 012
-0.55 011
-0.47 012
-0.47 011
-0.41 012
-0.39 006
-0.29 007
-0.39 009
-0.34 012
-0.34
.012
-0.37 013
+0.37 010
-0.36 010
-0.34 012
-0.42 EXT EXT LTE GTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 014 014 LTE. GTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 LTE GTE.
LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE-UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE -TE LTE UGTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL 1
UTIL 2
CAL #
WAR 22 WAR 20 WAR 28 WAR 0
82 WAR 0
84 WAR 0
82 WAR 0
82 WAR 84 WAR 82 WAR 20 WAR 20 WAR 20 WAR 22 WAR 19 WAR 20 WAR 20 WAR 22 WAR 20 WAR 22 WAR 22 WAR 5
20 WAR 28 WAR 28 WAR 5
591 WAR 70 WAR 84 WAR 7
84 WAR 84 WAR 82 WAR 22 WAR 22 WAR 21 WAR 20 WAR 20 WAR 4
639 WAR 0
82 WAR 0
82 WAR 0
84 WAR 0
84 WAR 0
84 WAR 100 WAR 0
20" WAR 22 WAR 22 WAR 21 WAR 20 WAR 0
20 WAR 5
20 WAR 22 WAR 22 WAR 0
22 WAR 20 WAR 3
20 WAR 82 WAR 82 WAR 82 WAR 84 WAR 82 WAR 84 WAR 4
84 WAR 84 WAR 5
2 WAR 6
20 WAR 4
20 WAR 5
20-WAR 20 WAR 0
84 WAR 0
84 WAR 0
82 WAR 82 WAR 84 WAR 100 WAR 100 WAR 0
100 WAR 2
WAR 22 WAR 0
22 WAR 20 WAR 22 WAR 22 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXB 510XB 510XB 51OXE 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repr 01/20/09 02:11:41 Component: S/G B Page 12 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.25 0.15 0.09 54 9
0.13 54 10 0.08 0.18 54 11 0.20 0.09 54 12 0.13 54 39 0.05 54 77 0.04 0.11 54 84 0.06 54 97 0.10 54 107 0.07 54 116 0.09 54 118 0.10 0.09 54 120 0.14 54 121 0.07 55 3
0.11 0.11 55 4"
0.19 55 5
0.10 55 6
0.09 0.29 0.06 0.08 0.07 55 7
0.14 0.12 55 8
1.75 0.09 0.09 0.28 0.43 0.23 55 10 0.09 55 12 0.17 0.07 55 50 0.06 55 52 0.07 55 86 0.07 55 103 0.07 55 116 0.09 55 117 0.08 55 118.
0.16 0.11 55 120 0.09 56 3
0.11 56 4
'0.20 56 6
1.'76 1.78 0*.09 0.35 0.80 0.38 56 7
0.14 56 8
0.10 56 12 0.21 0.08 56 15 0.14 56 18 0.08 56 19 0.15 0.24 56 42 0.06 56 44 0.11 56 57 0.09 56 79 0.15 56" 100 0.06 56 119 1.63 0.39 56 120 0.20 56 123 0.20 56 127 1.12 0.07 0.45 57 2.02 1.71 0.35 DEG CHN IND %Tt 138 P2 TWD 18 146 P2 TWD 12 151 P2 TWD 8 147 P2 TWD 8 147 P2 TWD 7 151 P2 TWD 14 122 P2 TWD 12 156 P2 TWD 6 141 P2 TWD 11 79 P2 TWD 4 63 P2 TWD 3 119 P2 TWD7 118 P2 TWD 4 153 P2 TWD 9 143 P2 TWD 5 158 P2
-TWD 8
147 P2 TWD 9 153 P2 TWD 8 143 P2 TWD 12 158 P2 TWD 5 128 P2 TWD 7 147 P2 TWD 7 145 P2 TWD 15 133 P2 TWD 7 151 P2 TWD 6 139 P2 TWD 16 141 P2 TWD 4 141 P2 TWD 5 138 P2 TWD 5 141 P2 TWD 12 152 P2 TWD 10 256 P2 VOL 149 P2 TWD 6 146 P2 TWD 6 143 P2 TWD 16 140 P2 TWD 22 142 P2 TWD 14 148 P2 TWD 6 143 P2 TWD 11 153 P2 TWD 5 144 P2 TWD 5 141 P2 TWD 6 142 P2 TWD 4 132 P2 TWD 6 154 P2 TWD 8 137 P2 TWD 5 148 P2 TWD 13
.153 P2 TWD 10 151 P2 TWD 8 122 P2 TWD 6 141 P2 TWD 12 68 P12 VOL 74 P2 VOL 147 P2 TWD 6 137 P2 TWD 19
.131 P2 TWD 32 136 P2 TWD 20 138 P2 TWD 12 138 P2 TWD 7 142 P2 TWD 13 149 P2 TWD..5 119 P2 TWD 11 149 P2 TWD 5 134 P2 TWD 12 135 P2 TWD 18 127 P2 TWD 5 137 P2 TWD 7 141 P2 TWD-6 136 P2 TWD 9 134 P2 TWD 6 95 22 VOL 140 P2 TWD 20 148 P2 TWD 16 146 P2 TWD 12 113 2 VOL 148 P2 TWD 7 138 P2 TWD 28 58 P18 VOL 53 P21 VOL 137 P2 TWD 23 W LOCATION 012 014 014 011 010 012
.013 012 011 007 009.
007 008 007 Ol Ol 013 Oli Oili 012 010 012 013 010 011 013 010 012 012 012 013 012 011 011 012 012.
013 010 012 012 008 007 007 008 Ol 009.
-012 010 012 006 012 012 012 010 011 012 012 010 011 012.
012 010 Oil A
012 012 A
008 A
007 A
007 007 008 A
011 011 011 012 011 007 011 012 011 011
+0.26
-0.50
+0.24
-0.39
-0.39
-0.45
-0.55
-0.52
+0.24
+0.15
+0.65
+0.10
+0.23
-0.57
+0.10
-0.47
-0.53
-0.42
+0.29
-0.39
-0.31
-0.36
+0.37
-0.36
+0.29
+0.34
-0.42
-0.39
+0.21
-0.42
+0.29
+0.26
-0.42
+0.23
-0.44
+0.26
+0.31
-0.39
+0.10
-0.49
+0.21
+0.13
+0.13
+0.23
-0.47
-0.39
+0.32
+0.63
-0.45
-0.31
-0.39
-0.39
+0.29
-0.34
+0.31
-0.39
+0.29
-0.34
-0.39
-0.49 r0.08 0.26 r0.16
-0.61 10.11 r0.13 10.03
-0.65
-0.60 10.21
-0.49 0.44
-0.42
-0.39
-0.26
-0.31
-0.31
-0.31
-0.31
-0.29 EXT EXT UTIL LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR
.LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 011 011 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 011 011 WAR LTE UTE WAR LTE UTE WAR 012 012 WAR 011 011 WAR LTE UTE WAR 1
UTIL 2
CAL #
22 22 0
22 0
20 22 3
22 20 4
20 22 28 70 70 70 4
639 82 0
84 84 0
84 84 82 2
2 22 20 20 20 4
20 2
20 3
20 22 22
.19 20 20 20 2020 -
0 20 20 4
20 5
571 5
571 70 3
639 0
84 82 84 0
.84 84 2
20 19 19 20 20
.20 20 22 20 20 0
20 0
22 20 22 22 3
571 28 4
591 70 4
639 81 82 84 82 91 92 92 99 99 100 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510UL 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510UL 510XB 510UL 510xp 510XB 510XB 510XB 510XP 510XB-510XB 510XP 510XP 51OXB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:41 Component: S/G B Page 13 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.45 0.11 0.11 57 4
0.16 0.16 57 5
0.08 57 6
0.15 57' 7
0.09 S0.10 57 11 0:13 0.07 57 12 0.08 57 27 0.09 57 65 0.09 57 90 0.07 57 98 0.10 0.07 0.05 57 101 0.08 57 120 0.08 57 121 0.14 58 1
0.15 58 2
0.13 58 3
0.75 "0.60 2.23 1.56 58 4
0.15 0.12 58 5
0.13 0.19 58 6
0.08 58 22 0.08 0.18 58 37 0.06 58 44 0.11 58
- 78.
0.09 0.07 58 83 0.09 58 94 0.05 58 115 0.14 58 120 0.27 59 1
1.72 0.08 0.09 0.58 0.19 0.25 59 0.08 0.29 0.06 59 3
0.61 0.33 0.21 1.98 59 4
0.37 0.08 0.33 59 5
0.09 59 7
0.09 59 34 0.08 59 49 0.07 59 55 0.13 59 60 0.08 59 69 0.10 59 81 0.07 59 93 0.05 59 102 0.11 59 106 0.09 59 108 0.ii 59 121 0.22 59 122 0.10 60 1,
1.36 0.09 0.08 0.54 0.15 0.08 60
.3 0.56 0.26 DEG CHN 131 P2 145 P2 138 P2 137 P2 147 P2 149 P2 143 P2 157 P2 153 P2 149 P2 154 P2 150 P2 144 P2 139 P2 148 P2 140 P2 151 P2 105 P2 132 P2 156 P2 146 P2 140 P2 148 P2 131 P2 132 P2 108 30 118 54 142 P2 151 P2 142 P2 144. P2
_129 P2 114 P2 141 P2 128 P2 138 P2 125 P2 92 P2 137 P2 106 P2 135 P2 143 P2 84 P17 149 P2 135 P2 129 P2 138.P2 141 P2 121 P2 138 P2 118 P2.
129 P2 137 P2 143 P2 115 54 141. P2 151 P2 142 P2 149 P2 154 P2 110' P2 137 P2 134 P2 117 P2 109 P2 122 P2 112. P2 75 P2 148 P2 141 P2 143 P2 136 P2 86 P18 133 P2 140 P2 131 P2 143 P2 155 P2 135 P2 141 P2 IND TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWDO TWD TWD VOL VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWO
%TW 28 10 10 9
9 7
9 8
9 11 6
5 7
6 7
7 5
4 8
7 9
13 8
29 25 9
7 8
11 7
5 11 5
7 8
7 6
3 12 15 8
8 33 16 19 5
15 4
2617 12 18 5
17 6
6 7
6 8
5 6
6 3
10 8
10 18.
6 9
8 31 13 7
24 14 LOCATION 012
-0.34 013
+0.42 009
+0.60 010
-0.31 012
-0.36 011
+0.34 012
-0.39.
'012
-0.40 012
+0.26 011
-0.45 011
+0.29 012
+0.08 013
+0.00 007
-0.59 007
-0.57 007
-0.52 008
+0.21 007
+0.18 007
-0.60 011
-0.44 011
-0.41 006
-0.31 006
-0.34 010
-0.31 012
-0.34 010
-0.39 012
-0.39 010
-0.31 011
+0.36 010
-0.34 012
-0.36 010
-0.37 014
-0.68 012
-0.60.
007
+0.03 007
+0.13 007
-0.65-008
-0.60 007
-0.57 007
+0.21 012
-0.55 011
-0.47 011
-0.28 003
-0.26 008
+0.41 011
-0.28 012
-0.29 013
._0.42 003
-0.26 012
-0.31 002
=0.26 010
-0.31 012
-0.36 011
+0.36 010
-0.36 011
+0.34 012
-0.34 013
-0.42 012
-0.39 012
+0.26 012
-0.03 007
+0.10 007
-0.62 007
-0.62 008
-0.64 007
+0.18 007
+0.23 007
-0.60 008
+0.26 014
+0.05 012
-0.45 011
+0.31 012
-0.34 001
-0.23 002
-0.26 012
-0.31 013
-0.36 013
+0.39 010
-0.31 011
+0.36 EXT EXT LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 010 010 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE Oil 011 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE
- LTE UTE LTE UTE 010 010 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 -012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE uTE LTE UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 1
UTIL 2
CAL #
100 100 100 2
2 18 16 18 18 22 0
22 4
20 0
567 158 4
625 82 0
82 82 0
639 84 82 10 2
2 2
1 1
2 2
16 16 18 6
569 6
569 4
571 28 0
625 0
625 70 70 92 90 9
10 10 10 10 10 2
2 2
2 0
2 17 2
2 2
16 0
571 0
571 6
591 4
591 0
631 4
625 70 0
639 2
639 2
639 92 4
90 9
10 10 10.
10.
4 10 2
2 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 51OUL 510XB 510ULo 510XB 510XBL 510XB 510LXB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XL 510XL 510XBL 510XB 510UL 510UL 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510UL 510XL 510DL 510UL 510UL 510UL 510OXB 51OUL 510UL 510UL 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: 0Nr2 Repi 01/20/09 02:11:41 Component: S/G B Page 14 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.42 0.34 0.08 0.11 1.09 1.63 60 4
0.14 0.25 0.19 0.17 60
- 5.
0.15 1.08 3.95 60 6
3.16 0.80 0.10 60 7
0.08 0.16 1.08 3*90 60 13 0.10 60 15 0.18 60 72 0.06 60 82 0.06 0.09 60 84 0.08 60 87 0.11 60 91 0.09 60 94 0 07 60 97 0.11 60 99 0.06 60 101 0.09 60 106 0.09 60 107 0.07 60 110 0.08 60 115 0.08 60 117 0.09 60 119 0.14 60 122 0.10 60 123 0.17 0.12 61 1
0.12' 0.09 0.07 61 3
0.64 0.51 0.08 1.63 1.49 61 4
0.20 0.22 61 6
0.12 0.19 0.22 61 7
0.20
.61 8
0.29 0.16 0.97 61
.12 0.16 61 13 0.19 0.13-61 14 0.10 0.17 61 48 0.:08 61 79 0.11 61 88 0.11 61 94 0.06 61 99 0.09 61 101 0.09 61 103 0.10 61 111 0.12 61 121 0.10 61 122 0.10 61 123 0.15 61 124 0.13 61 127 0.15-62 1
0.07 0.09 62 3
0.06 0.18 DEG 138 141 142 137 123 114 134 143 145 143 149 128 106 99.
133 157 149 146 128 107 150 138 63 132 133 135 133 147 136 130 150 92 104 128 157 155 144 152 156 149 144 134 136 129 131 138 149 117 118 144 143 135 143 147 140 139 137 104 146 146 144 145
-144 130 133 125 140 163 127 145 158 140 155 153
- 141, 141 99 131 138 144 CHN IND P2 TWD P2 TWO P2 TWO P2 TWO 54 VOL 54 VOL P2 TWD P2 TWO P2 TWD P2ý TWO P2' TWD P2 TWD 150 VOL 106 VOL P2 TWD P2 TWO P2 TWO P2 TWD P2-TWO 154 VOL P2 TWO P2 TWO P2' TWO P2 TWO P2 TWO P2 TWO P2 TWO P2 TWD P2 TWO P2 TWO P2 TWD P2 TWD P2
'TWD P2 TWD P2 TWO P2 TWD P2 TWO P2 TWO P2 TWO P2 TWD P2 TWO P2 TWD P2 TWO P2 TWO P2 TWO P2 TWO P2 TWD 54 VOL 54 VOL P2 TWO P2 TWD P2 TWD P2 TWD P2-TWD P2 TWO P2 TWO P2 TWD 110 VOL P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWO P2 TWD P2 TWD P2 TWO P2 TWO P2 TWO P2 TWD P2 TWO P2 TWD P2 TWO P2 TWO P2 TWO P2 TWD P2 TWD P2 TWD
%TW 20 17 5
7 8
13 11 10 13 42 31 7
7 13 42 9
14 6
4 5
5 9
6 4
7 6
8.
6 6
5 8
8 12 6
14 11 11 9
7 26 23 5
11 12 10 15 17 12 21 13 13 11 8
9 14 6
7 9
4 8
8 9
7 6
9 9
11 13 7
9 4
10' LOCATION 012
-0.34 013
+0.39 013
-0.39 012
+0.34 012
-0.37 010
-0.36 006
-0.31 013
-0.42 013
+0.31 011
+0.36 011
+0.26 012
+0.32 012
+0.24 012
-0.37 012
-0.39 015
+0.55 011
-0.42 012
-0.39 012
+0.29 012
+0.18 010
-0.44 014
-0.61 007
+0.10 008
+0.21 007
-0.60 006
+0.21 008
-0.60 007
-0.55 007
+0.18' 007
-0.64 007
-0.55 007
-0.60 008
+0.26.
008
+0.26 007
-0.50 007
-0.47 007
-0.44 012
-0.50 011
-0.41 011
-0.39 011
+0.31 003
-0.26 007
+0.41 009
-0.33 010
-0.31 012
-0.31 01i
+0.37 010
-0.36 012
-0.37 011
+0.36 012
-0.34 011
'-0.37' 012
-0.37 012
+0.29 013
-0.A7 012
-0.42 013
-0.50 012
-0.37 012
-0.47 011
-0.49 012
-0.52 011
-0.50 012
+0.13 007
-0.62 007
-0.62 007
-0.54 007
-0.52 007
-0.60 007
-0.57 007
-0.57 007
-0.51 012
+0.34 014
-0.47 Oil
-0.41 007
-0.34 011
+0.37 001
-0.20 012
-0.29 012
-0.37 011
+0.37 EXT EXT UTIL LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR 010 010 WAR LTE DIE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE-UTE WAR 010 010 WAR 012 012 WAR LTE UTE WAR LTE UTE' WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR.
LTE UTE WAR LTE UTE
-WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE' UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 1
UTIL 2
CAL # LEG 2
2
- 0.
2 0
21 1
2 22 6
'2 0
18 LAR 18 17.
15 16 16 18 5
18 LAR 18 17 18 18 4
633 70 0
70 70 5
633 70 70 4
631 0
639 3
639.
4 637
- 4.
639 5
637 5
92 4
92 5
92 90 92 92 10 10 5
10 2
2 0
2 1.
1 2
2 18 18 16 18 18 17 18
-16 16 18 18 3
571 70 7
633 70 4
639 3
639 3
639 90 4
90 5
92 90 92
.5 92 10.
4 10 2
0 2
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 51OXP 510XP 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510UL 510XB 510XB 510XB 510UL 510XB 510XB 510UL 510UL 510UL 510UL 510UL 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB*
510XB 510XP 510XB 510XB 510XB 510XB' 510XB" 510UL 510XB 510UL 510UL 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510OXB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:41 Component:
S/G B Page 15 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 62 4
0.57 0.28 1.54 62 5
0.20 1.60 5.22 62 6
0.37 0.29 0.10 1.08 0.69 62 7
0.08 0 11 62 10 0.40 0.89 62
- 12.
0:35 0.85 62 13 0.17 62 14 0.11 0.12 62 49 0.06 62 79 0.11 62 92 0.07 62 112 0.12 62 116 0.30 0.18 62 119 0.09 62 122 0.18 63 1
0.07 63 2
0.10 63 3
0.44
.1.35 63 4
0.34 0.65 0.18 0.09 1.81 63 5
0.11
- 0. 10 0.08 0.14 63 6
0.21 63 7
0.12 0.15 63 8
0.08 0:13 63 9
0.14 0.15.
63 10 0.32 1.71 63 13 0.12 0.12 63 14 0.12 63 15 0.15 0.12 63 53 0.06 63 55 0.07 63 67 0.10 63 81 0.07 63 87 0.08 0..05 63 89 0.09 63 92 0.09 63 93 0.09 63 100 0'.05 63 110 0.17 63 112 0.22 63 113 0.13 0.17 63 118 0.09 63 119 0.12 63 121 0.25 63 122 0.18 0.12 63 123 0.15 63 124 0.18 63 125 0.09 63 127 0.14 63 129 0.18 64 1
0.13 DEG CHN 135 P2 144 P2 116 54 144 P2 122 P2 93 130 138 P2 146 P2 141 P2 114 134 110 134 145 P2 151 P2 137 P2 103 134 140 P2 117 158 130 P2 152 P2 152 P2 145 P2 136 P2 105 P2 148 P2 141 P2 141 P2 155 P2 150 P2 148 P2 132 P2 135 P2 123 54 141 P2 135 P2 146 P2 152 P2 114 58 151 P2 147 P2 142 P2 149 P2 142 P2 152 P2 148 P2 123 P2 152 P2 140 P2 151 P2 144 P2 103 118 147 P2 148 P2 147 P2 136 P2 144 P2 93 P2 131 P2 120 P2 121 P2 12,0 P2 146 P2 131 P2 147 P2 139 P2 137 P2 137 P2 138 P2 154 P2 134 P2 134 P2 149 P2 145 P2 152 P2 152 P2 142 P2 145 P2 147 P2 141 P2 86 P2 150 P2 IND TWD TWD VOL TWD TWD VOL TWD TWD TWD VOL VOL TWD TWD TWD VOL TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW LOCATION 25 -012
-0.37 15 012
+0.31 012
-0.37 12 011
+0.31 43 012
-0.39 012
-0.39 24 012
+0.29 20 013
+0.32 9 *011
-0.37 012
+0.34 013
+0.37 5
011
-0.42 7
.012
+0.29 25 012
+0.24 012
+0.26 23 012
+0.21 012
+0.26 10 013
-0.60 10 010-
-0.44 10 011
-0.55 5
007
+0.13 7
007
-0.62 4
007
+0.21 7
011
+0.13
- 16. 011
-0.54 11 012
-0.55 8
012
+0.32 11 011
-0.46 7
006
+0.36 6
006
-0.31 21 010
-0.29 010
-0.29 17 011
+0.37 27 012
-0.34 10 012
+0.37 6
013
+0.34 012
-0.34 7
012
+0.34 6
.013
-0.44 5
011
-0.37 8
013
+0.31 16 013
+0.29 8
011
-0.39 9
013
-0.50 7
008
+0.34 11 014
+0.26 9
013
-0.57 10 012
-0.44 22 012
-0.45 012
-0.53 8
010
-0.44 8
012
+0.18 10 012
-0.53 9
013
-0.63 8
011
+0.16 5
'008
+0.21 5
007
+0.13 6
007
-0.64 6
006
+0.10 7
007 0.55 5
008
+0.23 8
007
-0.55 5
007
-0.61 8
007
-0.60 3
008
+0.23 10 011
-0.64 12 011
-0.60 12 007
-0.50 14 011
-0.60 6
007
-0.46 11 011
-0.50 19 011
-0.44 11 011
-0.46 7
012
-0.44 13 011
-0.42 11 011
-0.41 8
012
-0.45 12 012
-0.37 14 010
+0.70 12 013
+0.41 EXT EXT LTE UTE LTE UTE 012 012 LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE 012 012 013 013 LTE UTE LTE UTE LTE UTE 012 012 LTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE dTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 010 010 LTE UTE LTE UTE LTE UTE
ýLTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE UTE
-LTE UTE LTE UTE LTE UTE LTE' UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE
.LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR
-WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR.
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL #
2 0
2 1
0 16 LAR.
16 15 18 18 0
18 17 17 16 0
-16 18 17 18 17 16 18 18 3
571 70 70 6
90 90 90 4
92 90 10 2
2 1
2 2
2 2
1 2
2 0
2 5
2 18 16 16 18 18 16 4
16 18 17 16 16 18 16 0
16 3
571
- 5.
571 158 4
633 0
633 0
633 4
633 0
631 3
633 90 7
637 90 92 92 90 5
92 92 90 90 92 90 5
92 98 98 0
10 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET PROBE 510 XB 510XB 510XP 510XB 510XB 510XP 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XP 510XB 510XP 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XE 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510UL 510XB 510UL 51OUL 51OUL 51OUL 510XL 510UL 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
.510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:41 Component: S/G B Page 16 of 46 Component: S/C B Page 16 of 46 Service QUERY: u2sga.qry Induced Degradation ROW COL VOLTS 0.09 64 2'
0.22 0.15 64 3
0.10 64 4
0.64 0.15 0.10 1.72 64 5
0.45 0.20 1.27 64 6
0.13 64 7
0.14 64 8
0.11 64 9
0.41 0.13 1.48 64 10 0.25 64 13 0.18 0.12 64 14 0.22 64 17 0.09 0.21 64 70 0.09 64 77 0.07 64 81 0.11 64 82 0.07 0.08 64 87 0.08 64 89 0.11 64 93 0.09 64 100 0.08 64 104 0.13 64 110 0.09 64 114 0.11 64 116 0.17 64 118 0.14 64 119 0.21 64 121 0.19 64 122 0.14 64 123 0.32 64 124 1.56 0.29 0.05 64 131 0.10 65 1
2.53 0.85 65 2
0.16 65 5
0.15 0.11 65 13 0.27 0.32 65 14 0.13 0.23 0.10 0.14 65 16 0.09 65 54 0.07 65 74 0.05 65 76 0.09 65 86 0.11 65 94 0.10 65 95 0.06 65 109 0.10 65 113 0.07 65 115 0.13 65 116 0.11 0.10 65 117 1.46 0.28 0.07 65 118 0.36 0.17 0.21 0.12 65 121 0.16 65 122 0.09 0.36 65 123 0.10 65 124 0.15 DEG 144 136 150 151 131 150 117 113 137 140 123 141 136 142 141 151 92 138 142 144 140 148 132 140 132 84 118 56 25 124 147 136 50 131 143 139 137 143 144 150 142 100 142 157 148 82 128 136 152 146 143 138 143 145 139 144.
135 138 118 67 145 140 144 151 126 145 143 139 97 137 136 140 149 140 137 149 146 144 158 149 CHN P2 P2 P2 P2 P2 P2 P2 54 P2 P2 54 P2 P2 P2 P2 P2 114 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 30 P2 P2 P2 P19 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 34 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWO TWD TWD TWD TWD TWD TWD VOL TWD TWD VOL TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW 8
12 9
6 27 9
6 21 11 8
11 7
26 11 14 14 10 13 8
16 6
5 7
6 7
7 10 8
7 11 8
10 14 12 12 11 12 17 21 5
9 39 9
9 7
15 17 11 17 9
12 8
7 5
8 7
6 6
6 7
12 7
6 21 7
18 10 12 7
13 6
18 9
9 LOCATION 010
-0.28 010
-0.29 013
+0.42 013
+0.39 010
-0.31 011
+0.34 006
-0.36 010
-0.34 010
-0.31 013
+0.34 010
-0.36 012
-0.37 013
+0.32 013
+0.29 012
-0.42 012
+0.26 012
-0.45 012
+/-0.26 011 z0.53 012"
-0.50 012
+0.21 011
-0.55 012
+0.16 007
-0.64 008
+0.21 007
-0.62 008
+0.18 007
+0.16 007
-0.52 007
-0.55 007
-0.60 008
+0.21 008
+0.23 007
-0.52 006
-0.39 012
-0.58 011
-0.52 012
-0.55 012
-0.49 011
-0.44 011
-0.44 011
-0.47 011
-0.44 011
+0.29 007
-0.31 012
-0.29 012
-0.29 013
+0.39 011
+0.34 013
+0.34 012
+0.21 014
-0.60 011
+0.18 012
-0.50 014
-0.64 014
+0.13 007
-0.44 007
-0.60 007
+0.08
.008
+0.21 007
-0.55 007
-0.57 007
+0.23 007
-0.57 010
+0.13 011
-0.58 007
-0.46 011
+0.13 012
-0.59 012
-0.55.
011
+0.21 012
-0.52 010
+0.57 011
-0.52 011
+0.23 Oil
-0.47 014
-0.50 011
-0.46 011
-0.42 011
-0.41 EXT LTE LTE LTE LTE LTE LTE LTE 010 LTE LTE 010 LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 011 LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTE UTE UTE UTE UTE UTE UTE 010 UTE UTE 010 UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 011 UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 1
UTIL 2
CAL # LEG 5
10 2
2 0
2 2
2 6
.2 1
2 2
1 16 18 16 18 18 17 8
16 18 18 16 18 18 162 70 6
631 4
633 2
633 0
633 7
633 2
633 4
639 5
639 3
639 5
92 5
92 5
92 90 90 92 90 91 92 92 98 9
10 2
2 0
2 16 16*
18 18 18 1818 0
525 0
629 2
633 70 70 72 90 4
92 92 90 3
90 91 92 5
92 90 7
90 7
90 3
90 5
92.
90 90 92 90 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET
-INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510 XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510UL' 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:41 Component: S/G B Page 17 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.09 65 126 0.08
- 65.
130 0.13 66 1
0.10 66 3
0.13 0.14 0.17 66 5
0.13 66 6
0:14 66 7
0.12 66
- 10.
0.12 66 18 0.13 66 51 0.07 66 72 0.09 66 74 0.06 66 80 0.10 66 81 0.07 66 85 0.07 66 87 0.10 66 88 0.11 66 89 0.11 66 97 0.06 66 103 0.08 66 105 0.10 66 111 0.14 66 114 0.90 0.29 66 116 0.09 0.21 66 118 0.14 0.17 0.13 66 119 0.08 0.17 66 120 0.13 0.12 66 121 0.18 66 122 0.21 0.14 66 123 0.27 66 124 0.08 66 127 0.10 66 129 0.09 66 131 0.19 0.04 0.11 67 1
0.12 67 2
0.10 67 3
0.10 67 4
0.07 67 6
0.06 67-7 0.15 0.20 67 9
0.22 67 13 0.38 1.27 67 14 0.15 0.15 67 16 0.16
-0.08 0.17 0.21 67 22 0.09 67 53 0.07 67 64 0.17 0.12 67 78 0.05 67 86 0.08 67 87 0.11 67 89 0.08 67 93 0.07 67 95 0.07 67 i11 0.12 67 114 0.16 67 115 0.21 67 116 0.45 0.24 2.13 67 117 0.16 67 118 0.12 DEG CHN 152 P2 142 P2 148 P2 140 P2 123 P2 144 P2 147 P2 138 P2 143 P2 142 P2 143 P2 142 P2 149 P2 146 P2 122 P2 147 P2 130 P2 106 P2 133 P2 136 P2 137 P2 143 P2 146 P2 133 P2 147 P2 155 82 125 P2 134 P2 136 P2 156 P2 148 P2 137 P2 147 P2 142 P2 151 P2 143 P2 146 P2 145 P2 143 P2 142 P2 149 P2 158 P2 146 P2 147 P2 160 P2 139 P2 152. P2 147 P2 147 P2 120 P2 158 P2 143 P2 145 P2 138 P2 139 P2 126 154 147 P2 133 P2 146 P2 142 P2 134 P2 142 P2 141 P2 153 P2 4132 P2 109 P2 108 P2 112 P2 126 P2 132 P2 139 P2 127 P2 144 P2 145 P2 138 P2 139 P2 138 P2 93 30 150 P2 150 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWDO TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWO TWD TWD TWD TWD VOL TWD TWD
%TW 5
7 11 10 8
8 10 7
9 10 7
8 5
8 5
6 4
5 6
10 9
5.
5 6
8 21 9"17 13 15 12 5
10 12 11 10 17 13 15 8
9 7
15 3
9' 11 6
6 4
6 10 12 13 20 12 12 13 7
14 16 6
7 10 8
5 5
9 7
5 5
10 9
17 21 13 14 7
LOCATION 011
+0.31 012
-0.39 007
-0.29 011
-0.31 010
+0.70 011
-0.34 013
+0.39 011
+0.34 012
+0.31 013
+0.29 007
+0.31 012
+0.13 008
+0.21 008
-0.60 008
+0.16 007
-0.56 007
+0.10 007
+0.10 007
+0.16 007
-0.57 007
-0.57.
007
-0.57 011
-0.75 007
+0.18 007
-0.51 012
-0.68 012
-0.61 007
-0.47 011
-0.60 010
+0.60 012
-0.53 012
+0.26 011
+0.23 011
-0.54 011
-0.52 012
+0.18 011
-0.54 011
-0.44 012
+0.34 011
-0.44 011
+0.29 012
-0.37 011
-0.34 011
+0.39 009
-0.34 011
-0.31 013
+0.42 012.
+0.39 013
-0.39 007
-0.34 01i
+0.32 013
+0.31 012
-0.37 012
+0.31 012
-0.52.
012
-0.52 012
-0.50-012
+0.18 012
-0.53 012
+0.16 013
-0.61 011
-0.53 012
+0.03 007
-0.62 007
-0.61 008
-0.59 008
+0.16 007
+0.16 007
-0.57 007
-0.57 007
-0.52 007
+0-16 007
-0.52 006
-0.41 011
-0.60 014
-0.63 011
-0.57 014
-0.65 010
+0.21 007
-0.41 EXT EXT UTIL 1
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR.
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE
- WAR, LTE UTE-WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE
'WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 014 014.
WAR LTE UTE WAR LTE UTE WAR UTIL 2
CAL 90 98 98 6
10 2
2 0
2 0
2 4
16 18 16 5
16
- 4.
527 6
629 3
629 5
631 70 70 70 72 6
633 0
633 90 90 90 91 92 92 92-92 92 5
92 90 5
90 92 5
92 5
90 92 92 90 4
92 98 98 98 98 4
98 10 2
0 2
2 18 16 0
16 16
. 16 15 18 18 18 18 18 0
18 16' 0
525 162 162 0
633 70 0
633 0
633 70 70 8
635 90
.92 90 5
90 89 92 90
- LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET-INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 5.10XB 510XB 510XB 510XB 510XB 51OUL 510UL 51OUL 510UL 510XB 510XB 510XB 510XB 510UL 510UL 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXB 510XB 510XB 510XB 510XB 510XB-510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB.
510XB 510XB 510XB 510UL 510XB 510XB 51OUL 510XB 51OUL 510UL 510XB 510XB 510DL 510XB 510XB 510XB 510XB 510XP 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:41 Component: S/G B Page 18 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.18 0.20 67 119 1.51 0.17 0.57 0.14 0.15 67 120 0.26 67 121 0.16 0.05
- 67.
124 0.09 68 1
0.74 0.07 0.29 68 2
0.08 0.19 0.18 68 3
0.10 0.19 0.09 68 5
0.44 1.25 68 6
0.10 68 8
0.21 68 10 0.70 0.29 0.21 0.14 0.14 1.91 0.81 68 71 0.13 68 79 0.07 68 93 0.10 68 95 0.10 68 112 0.09 0.08 68 113 0.14 68 115 0.24 0.30 68 116 0.17 0.13 0.16 68 118 0.15 0.20 68 119 0.28 68 120 0.15 69 2
0.18 69 4
0.23 0.12 69 5
0.08 69 9
0.29 1.30 69 12 0.19 0.14 69 13 0.16 0.21 69 14 0.23 69 15 0.32 1.82 69 17
.0.12 0.08 0.18 69 22 0.13 69 87 0.07 69 89 0.08 69 90 "0.10 69 93 0.07 69 95 0.06 69 111 0.12 69 112 0.12 0.23 69 113 0.22 69 114 0.13 69 116 0.07 69 118.0.13 0.10 69 122 0.24
- 0.11.
0.09 DEG CHN IND 147 P2 TWD 142 P2 TWD 96 66 VOL 131 P2 TWD 138 P2 TWD
.142 P2 TWD 147 P2 TWD 143 P2.
TWD 151 P2 TWD 69 P2 TWD 153. P2 TWD 87 P20 VOL 144 P2 TWD 138 P2 TWD 128 P2 TWD 140 P2 TWD 141 P2 TWD 88 P2 TWD 132 P2 TWD 140 P2 TWD 137 P2 TWD 120 54 VOL 137 P2 TWD 146 P2 TWD 130 P2 TWD 144 P2 TWD 140 P2 TWD 151 P2 TWD 119 P2 TWD 96 142 VOL 113 134 VOL 124 P2 TWD 74 P2 TWD 149 P2 TWD 134 P2 TWD 148 P2 TWD 120 P2 TWD 140 P2 TWD 133 P2 TWD 140 P2 TWD 144 P2 TWD 123 P2 TWD 138 P2 TWD 141 P2 TWD 142 P2 TWD 145 P2 TWD 151 P2 TWD 139 P2 TWD 136 P2 TWD 150 P2 TWD 146 P2 TWDO 142 P2 TWD 100 142 VOL 144 P2 TWD 145 P2 TWD 146 P2 TWD 140 P2 TWD 139 P2 TWD 145 P2 TWD
.93 118 VOL 139 P2-TWD 155 P2 TWD 132 P2 TWD 115 P2 TWD 126 P2 TWD 142 P2 TWD 138 P2 TWD 136 P2 TWD 80 P2 TWD 145 P2 TWD 146 P2 TWD 138 P2 TWD 131 P2 TWD 147 P2 TWD 159"P2 TWD 14*4 P2 TWD 148 P2 TWD 143.P2 TWD 129 P2 TWD 157 P2 TWD
%TW 15 32 12 13 14 14 5
6 7
21 5
11 10 6
11 6
21 9
16 35 21 16 12 12 8
6 9
8 8
7 8
13 16 15 11 14 13 16 15 13 11 13 8
8 21 12 9
13 16 13 22 10 7
15 10 6
7 6
6 4
7 11 18 13 11 7
12 9
19 10 8
LOCATION 010
+0.57 012
-0.55 010
+0.50 010
+0.21 010
+0.58 011
-0.52 012
-0.53 011
-0.52 011
-0.50 011
+0.24 014
-0.45 012
-0.29 008
-0.31 012
-0.26 006
-0.31 011
-0.34 012
+0.42 006
-0.36 012
-0.32 014
-0.34 010
-0.31 010
-0.39 013
+0.34 014 70.47 010
-0.39 012
+0.29 013
-0.55 013
+0.24 010
+0.00 010
-0.47 012
+0.34 007
-0.64 007
+0.16 007
-0.57 007
-0.55 007
-0.52 012
-0.65 007
-0.49 011
-0.57 012
-0.57 012.
-0.55 014
-0.53 011
+0.16 011
+0.21 012
-0.55 011 70.52
.011
-0.50 012
-0.29 013
+0.39 014
-0.37 013
+0.37 010
-0.39 010
-0.45 012
-0.45 012
+0.24 010
-0.42 012
+0.21 012
+0.21 012
-0.50 012
-0.53 012
-0.53 012
+0.16 014
-0.63 011
-0.63 007
+0.18 007
-0.57 007
-0.54 007
-0.57 007
+0.18 007
-0.51 007
-0.52 011
-0.63 011
-0.62 007
-0.52 007
-0.44 010
+0.18 011
+0.18 014
-0.50 014
+0.21 012
-0.47 EXT LTE LTE 010 LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE 010 LTE LTE LTE LTE LTE LTE LTE 010 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE tTE LTE LTE LTE LTE LTE LTE LTE 010 LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTIL 1
OTE WAR UTE WAR 010 WAR 0TE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 012 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 010 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 010 WAR 012 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 010 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 012 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR.
UTIL 2
CAL #
90 5
90 91 92 92 92 92 90 92 92 90 9
10 10 2
2 2
6 6
0 6
2 1
18 18 18 18 18 6
18 18 17 17 162 5
633 2
633 6
633 7
635 5
635 90 90 90 92 92 6
92 92 92 90 5
92 6
6 6
0 6
0 100 18 17 16 16 18 18 16 18-17 18 18 18 6
563 4
633 5
633 5
631 4
633 70 90 92
.92 6
90 92 92 5
92 0
92 92 92 4
92 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET
- INLET, INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE.
510OXB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 51OUL 51OUL 51OUL 510UL 51OUL 510XB 510XB 510XB 510XB 51OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 51OUL 51OUL 510UL 510UL 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:41 Component: S/G B Page 19 of 46 Service QUERY: u2sga.qry ROW COL VOLTS DEG 69 129 0.11 142 69 132 0.09 153 70 1
0.12 117 0.18 134 70 2
0.14 143 0.07 148 70 5
0.20 144 70 10 0.08 145 0.19 143 70 13 0.16 139 0.19
.141 70 14 0.13 140 0.15 143 0.63 134 0.24 134 0.30 132 1.42 85 2.55 88 70 15 0:07 134 70 77 0.13 121 70 78 0.11 123 70 91 0.08 126 70 93 0.07 139 70 95 0.09 130 70 97 0.10 114 70 112 0.19 137 70 113 0.12 143 70 114 0.18 126 70 124 0.12 142 71 1
0.09 153 0.22 143 0.14 138 0.22 142 71 2
0.12 140 0.12 135 0.23 139 0.08 116 71 10 0.14 145 71 13 0.17 146 0.21 148 71 14 0.56 135 1.65 122 71 16 0.20 141 71 17 0.09 141 71 18 0.23 141 71 23 0.07
.155 71 76 0.0,6 119 71 81 0.12 120 71 85 0.11 122 71 89 0.08 139 71 91 0.06 150 71 95 0.07" 147 71 96 0.12 138 71 98
-0.07 156 71 111 0.12 136 71 113 0.09 134 71 117 0.16 137 71 119 0.15 141 0.15 132 71 126 0.09 142 0.22 148 71 127 0.12 142 71 130 0.08 140 71 131 0.10 127 72 1
0.83 78 0.13 152 0.09 150 0.37 134 72 3
0.08 132 72 4
1.70 91 0.40 135 0.09 157 72 5
0.15 140 72 6
0.21 142 0.14 143 72 7
0.13 147 72 9
0.30 134 0.07 136 72 10 0.30 137 1.04 82 Induced Degradation CHN IND P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD 94 VOL 118 VOL P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD 150 VOL P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P19 VOL P2 TWD P2 TWD P2 TWD P2 TWD P10 VOL P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD 46 VOL
%TW LOCATIOJ 9
011 8
011 11 002 15 011 12 011
- 7.
012 12 013 7
007 15 013 10 011 11 013 11 011 13 011 33 012 18 013 21 014 014 012 5
006 11 007 7
007 7
007 5
007 6
007 8
007 11 012 7
007 15 011 11 011 8
003 17 003 12 008 17 012 7
006 8
011 13 012 5
007 9
012 14 010 16 012 25 012 012 12 012 8
012 13 012 6
012 5
007 10 007 10 007 7
007 6
007 4
007 10 007 6
007 7
007 6
014 9
014 9
007 9
012 8
007-18 014 10 011.
7 007 9
007 012 11 009 8
011 25 012 5
006 012 26 012 8
013 9
013 17 012 11 013 8
012 16 010 5
012 21 007 007
+0.37
+0.42
-0.26
-0.29
-0.31
-0.29
+0.37
-0.39
-0.55
-0.52
+0.18
-0.53
+0.16
-0.53
-0.58
-0.58
-0.61
-0.55
-0.47
-0.60
-0.59
-0.57
-0.55
-0.55
-0.55
-0.65
-0.49
-0.60
+0.29
+0.03
+0.46
-0.31
-0.26
-0.34
-0.34
-0.29
-0.29
+0.26
-0.42
-0.50
-0.50
-0.50
+0.16
+0.13-
+0.16
+0.05
+0.08
-0.60
-0.57
-0.55
-0.55
-0.55
-0.55
-0.55
-0.49
-0.63
-0.58
-0.41
-0.55
-0.36
+0.29
+0.29
-0.31
-0.31
-0.29
+0. 65
-0.29
-0.29
-0.34
+0 37
+0.37
+0.39
-0.39
+0.34
+0..32
+0.31
-0.39
+0.26
-0.39
-0.39 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 014 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE 007 EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE.
UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE 007 UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL # LEG 4
98 INLET 4
98 INLET 10 INLET 10 INLET 3
10 INLET 2
10 INLET 6
INLET 5
18 INLET 18 INLET
- 16.
INLET 16 INLET 18 INLET 18 INLET 18 INLET 18 INLET 18 INLET 17 INLET 17 INLET 16 INLET 6
633 INLET 6
631 INLET 4
633 INLET 70 INLET 70 INLET 3
633 INLET 90 INLET 90 INLET 92 INLET 5
92 INLET 10 INLET 10 INLET 10 INLET 10 INLET 6
INLET 6
INLET 6
INLET 5
6 INLET 16 INLET 18 INLET 18 INLET 16 INLET 15 INLET 16 INLET 18 INLET 16 INLET 4
565 INLET 2
629 INLET 2
633 INLET 4
633 INLET 2
633 INLET 2
633 INLET 70 INLET 5
633 INLET 3
633 INLET 90 INLET 90 INLET 90 INLET 90 INLET 90 INLET 92 INLET 92 INLET 5
98 INLET
-98 INLET 98 INLET 9
INLET 10 INLET 10 INLET 10 INLET 6
INLET 9
INLET 10 INLET 5
10 INLET 6
INLET 18 INLET 18 INLET 16 INLET 16 INLET 16 INLET 18 INLET 17 INLET PROBE 510 XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 51OUL 51OUL 51OUL 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB' 510XB 510XB 510XP 510XB 510XB 510XB 510UL 510UL 510UL 510UL 510UL 510UL 510XB 51OUL
-51OUL 510XB 510XB 510XB 510XB 510XB 510XB..
-510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XBE 510XB 510XB 510XB 510XB 510XB 510XP
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:41 Component: S/G B Page 20 of 46 Service QUERY: u2sga.qry ROW COL VOLTS DEG 72 12 0.29 136 0.09 146 0.79 110 72 13 0.23 139 0.50 134 0.10 138 1.35 126 72 68 0.08 137 72 87 0.08 145 72 91 0.08 137 72 95 0.09 147 72 ll 0.09 149 72 112 0.83 127 0.29 127 72 113 0.14 144 0.09.
134 0.16 132 72 116 0.12 145 72 117 0.15 138 72 129 0.20 146 72 130 0.11 130 72 131 0.23 147 73 1
2.24 79 0.76 79 1.65 102 2.39 265 1.32 93 1.60 85 1.92 86 0.95 91 0.41 133 0.15
.136 0.24 140 0.09 136 0.12 132 0.13 144 0.28 "136 0.11 133 0.19 140 0.26 142 0.27 135 0.09 92 0.56
.129 0.09 137 0.47 138 0.82 130
.73 2
0.17 130 0.12
.133 73 3
0.13 142 0.09 143 0.09 136 0.13 144 0.09 142 0.09 154 73
.4 0.24 143 73 5
0.11 144 73 6
o.1i 131 73 9
0.18 142 0.20 145 73 10 0.16 147 73
.11,
.0.11 147 0.10 143 73 13
'0.25 144 0.14 144 73 14 0.59 132 0.11 147 1.55 125 73 76 0.06 124 73 82 0.09 110 73 83 0.11 i1 73 84 0.11 125 73 86 0.09 135 73 87 0.10 127 73 89 0.10 143 73 90 0.06 101 73
.94 0.08 148 73 96 0.07 151 73 97 0.07 151 73 11 0.15 126 73 113 0.23 140 Induced Degradation CHN P2 P2 158 P2 P2 P2 126 P2 P2 P2 P2 P2 18 P2 P2 P2 P2 P2 P2 P2 P2 P2 P19 P16 P5 P1I P28 P7 P7 P26 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 150 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND TWD TWD VOL TWD TWD TWD VOL TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL VOL VOL VOL VOL VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD.
TWD TWD
-TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW 20 8
13 24 7
5 7
5 6
6 22 9
5 10 11 9
15 9
17 28 17 27 13 19 8
11 11 21 10 15 20 20 8
32 8
29 39 10 7
12 9
8 11 8
8 14 10 7
14 16 10 9
9 19 12 26 7
5 6
7 7
6 6
6 5
7 6
5 9
13 I LOCATIO0 012 013 012 010 012
- 012, 012 007 007 007 007 O7 Oili Oili 011 013 014 Ol 011 Oili 007 Ol 012 011 009 007 006 003 002 002 003 003 004 004 006 006 006 008 008 009 01!
010 007 013 002 012 006 006 004 004 006 006 008 012 012 013 013 013 014 012 011 012 012 012 012 012 012 007 007 007 007 007 007 007 007 007 007 007 011 012 N
+0.21
+0.24
+0.26
-0.44
-0.50
- +0.21
-0.55
+0.15
-0.57
-0.60
-0.57
-0.49
-0.68
-0.60
+0.10
+0.03
-0.65
+0.13
-0.60
-0.36
-0.28
+0.42
+0.00
-0.31
+0.52
+0.00
+0.31
-0.21
+0.00
+0.36
-0.23
+0.18
-0.26
+0.41
-0.31
-0.03
+0.36
-0.29
+0.36
+0.62
-0.31
-0.18
+0.00
-0.31
+0.00
-0.10
-0.34
+0.36
-0.28
+0.36
-0.34
+0.31
-0.31
+0.39
-0.31
-0.37
-0.42
-0.45
-0.48
-0.42
+0.26
+0.26
-0.50
+0.21
-0.50
+0.18
-0.45'
+0.13
-0.59
-0.60
-0.57
-0.56
-0.55
-0.54
+0.13
-0.55
-0.57
-0.54
-0.62
-0.65 EXT EXT LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE Oil 011 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 011 011 009 009 007 007 006 006 003 003 002 002 002 002 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE
-LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 1
UTIL 2
CAL # LEG 18 3
18 17 16 16 16 15 162 2
633 70
.70 90 91 92 90 90 90 5
92 90 98 98 98 9
9 9
9 9
9 9
9 10 10 10 10 10 10 10 10 10 10 10 io0 10 4
10 10 10 6
7 6
10 10 10 10
- 10 10
.6
- 6.
10 0
6 18 18 0
16 18 18 18 18 16 16 15 5-5 629 4
631 70 70 0
631 70 4
631 5
633 2
633 2
-633 4
631 90 90 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XP 510XB 510XB 510XB 510XP 510XB 510UL 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XP 510XP 510XP 510XP 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 5'1OXB 510XB 510XB 510XB 510XB 510XB 510XP 51OUL 51OUL 510XB 510XB' 51OUL 510XB 510UL-51OUL 51OUL 51OUL 51OUL 510XB 510XB
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:11:42 Component: S/G B Page 21 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 73 115 0.07 73 116 0.53 0.28 0.09 73 117 0.15 73 119 0.17 73 125 0.08 73 131 0.10 0.07 0.09 73 132 0.08 0.11 0.13 0.10 0.09 74 1
0.96 1.74 1.11 1.44 2.45 1.71 0.85 0.07 0.11 0.15 0.05 0.36 0.08 0.09 0.07 0.09 0.33 0.12 0.14 0.08 0.12 0.11 0.32 0.26 0.17 0123 0.08 0.11 1.00 74 2
1.05 0.12 0.16, 0.15 0.14 0.15 0.18-0.37 0.11 0.12 0.09 74 4
0.10 74 9
0.22 0.16 74 10 0.13 0.12 74 12 0.19
.0.11 74 13 0.14 0.28 74 14 0.24 74 17 0.13 74 52 0.10 74 86 0.09 74 89 0.11 74 90 0.08 74 91 0.11 74 93, 0.13 74 94 0.12 0.11 0.08 74 95 0.11 74 109 0.09 74 112 0.08 74 115 0.18 74 116 1.57 DEG 129 146 143 128 145 149 128 135 144 153 158 150 143 143 143 80 98 90 82 87 97 77 132 144 136 152 135 149 125 124 148 134 138 133 127 134 113 137 137 137 144 134 141 137 78 137 139 118 140 137 136
-135-138' 129 13.
149 144 1*47 148 150 145 151 144 148 140 129 115 145 143 139 127 137 134 132 122 147 144 130 143
.113 CHN IND %TW P2 TWD 4 18 VOL P2 TWD 21 P2 TWD 8 P2 TWD 9 P2 TWD 10 P2 TWD 5 P2 TWD 8 P2 TWD 6 P2 TWD 8" P2 TWD 6 P2 TWD 9 P2 TWD 10 P2 TWD 8 P2 TWD 7 P16 VOL P5 VOL P10 VOL P8 VOL P26 TWD 32 P7 TWD 26 P17 TWD 15 P2 TWD 7 P2 TWD 10 P2 TWD 13 P2 TWD 5 P2 TWD 25 P2 TWD 7 P2 TWD 8 P2 TWD 7 P2 TWD 8 P2 TWD 23.
P2 TWD 11 P2 TWD 12 P2 TWD 7 P2 TWD 11 P2 TWD'I0 P2 TWD 23 P2 TWD'20 P2 TWD 15 P2 TWD 18 P2 TWD 8 P2 TWD 10 P2 TWD 42 P19 VOL P2 TWD 11 P2 TWD 14 P2 TWD 13 P2 TWD 13 P2 TWD 13 P2 TWD 15 P2 TWD 25 P2 TWD 10 P2 TWD 11 P2 TWD 8 P2 TWD 9 P2 TWD 13 P2 TWD 10 P2 TWD 11 P2 TWD 10 P2 TWD 15 P2 TWD 10 P2 TWD 9 P2 TWD 15 P2 TWD 18 P2 TWD 8 P2 TWD 9 P2 TWD 5 P2 TWD 7 P2 TWD 5 P2 TWD 9 P2 TWD 8 P2 TWD 7 P2 TWD 7 P2 TWD 5 P2 TWD 9 P2 TWD 6 P2 TWD 7 P2 TWD 11 66 VOL LOCATION 011
-0.59 012
-0.68 012
-0.58 012
+0.16 011
-0.57 012
-0.54
.011
+0.28 003
-0.23 003
+0.18 009
+0.65 006
+0.36 007
+0.36 011
-0.28 007
-0.05 011
+0.42 010
-0.26 009
+0.57 006
-0.31 004".
-0.31 002
+0.39 002
-0.23 002
+0.00 001
-0.21 001
+0.44 003
-0.23 003
+0.15 004
-0.31, 004
+0.08 004
+0.39 005
-0.34 005
+0.39 006
-0.34 006
+0.03 006
+0.36 007
-0.23 008
-0.31 009
+0.29 009
+0.62
.010
-0.26 011
-0.29 012
-0.31 012
+0.42 013
+0.39 002
+0.00 012
-0.31 001
-0.21 001
+0.46 004
-0.31 004
+0.39 006
-0.31 011
-0.34 012
-0.31 009
+0.62 008
-0.31 008
+0.36 013
+0.39 010
-0.39 012
+0.29 013
+0.26 012
+/-0.26
.012
+0.18 012
-0.47 010
-0.36 012
-0.50 012
+0.18 007
-0.44 008
-0.57 007
-0.55.
007
-0.56 007
+0.16 007
-0.60 007
-0.57 007
-0.57 009
-0.57 007
+0.23 007
-0.57 007
-0.54 011
-0.67 010
+0.13 010
+0.08 EXT LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 010 009 006 004 002 002 002 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE' LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 010 EXT UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 009 006 004 002 002 002 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE' UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 010 UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR-WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR.
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL 90 91 92 4
.92 90 90 0
90 98 98 98 118 118 118 8
118 2
118 9-9 9
9 9
9 9
10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 10 LAR 10 9
10 10 10 10 10 10 10 10 5
10 4
10 5
10
'16 16 18 0
18 18 0
18 5
16 0
16 18 16
- 5.
525 70 5
631 70 4
633 70 70 70 6
70 3
633 90 5
635 3
90 91
- LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET
-INLET-INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
.510XB 510XB 510XB 510xB 510XB 510XP 510XP 510XP 510XP 510XP 510XP
.510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB
.510XB 510XB 510XB 510XB
- 510XB S510XB 510XB 510XB 510XB 510XB 510XB 510XB
.510XB
.510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510UL 510XB 510XB 510XB 510XB 510UL 510XB 510UL 510XB 510XP
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:42 Component: S/G B Page 22 of 46 Service QUERY: u2sga.qry ROW COL VOLTS DEG 0.43 132 74 119 0.13 143 0.12 145 74 120 0.15 148 74 131 0.16 139 0.25 148 0.19 145 0.21 149 75 1
1.61 82 1.12" 82 1.52 107 1.63 87 0.79 64 1.30 82 0.58 214 1.07 96 0.58 103.
1.07 88 0.09 128 "0.08 129 0.52 132 0.16 145 0.10 124 0.09 137 0.34 136 0.22 136 0.13 141 0.30
.141 0.28 129
- 0.06 138 0.18 133 0.54 138.
0.53 135 75 3
0.15 134 75 4
0.15
'136 75 5
1.05 94 0.26 140 75 10 0.08 151 0.10 147 75 14 0.21 150 75 15 0.13 142 0.27 142 0.11 139 1.57 100 75 16 0.27 141 75 17 0.19 134 75 72 0.14 118 75 81 0.11 78 0.07 62 75 83 0.11 59 75 87 0.06 74 75 91 0.10 139 75 92 0.10 146 75 94 0.15 140 75 95 0.08 131 0.07 127 75 96 0.08 139 75 97 0.10 128 75 99 0.09 142 75 112 0.10 143 75
.113 0.10 130 75 116 0.18 134 75 117 0.09 140 75 119 0.06 150 75 120 0.14 146 75-131 0.11 142 0.21 147 0.07 154 75 132 0.22 133 0.08 140 0.06
-153 0.10 140 0.27 144 76 1
0.13 133 0.15 132 0.07 110 0.08 129 0.22 138 0.10 147 0.14 145 Induced Degradation CHN IND %TW P2 TWD 28 P2 TWD 8 P2 TWD 7 P2 TWD 13 P2 TWD 12 P2 TWD 17 P2 TWD 13 P2 TWD 15 P20 VOL P14 VOL 58 VOL P8 TWD 25 P17 TWD 15 P27 TWD 21 P17 TWD 11 P28 TWD 18 P28 TWD 11 P9 TWD 18 P2 TWD 8 P2 TWD 7 P2 TWD 31 P2 TWD 14 P2 TWD 9 P2 TWD 8 P2 TWD 24 P2 TWD 17 P2 TWD 11 P2 TWD 22 P2 TWD 21 P2 TWD 6 P2 TWD 15 P2 TWD 32 P2 TWD 31 P2 TWD 13 P2 TWD 9 P20 VOL P2 TWD 20 P2 TWD 5 P2 TWD 7 P2 TWD 12 P2 TWD 11 P2 TWD 20 P2 TWD 9 138 VOL P2 TWD 15 P2 TWD 15 P2 TWD 9 P2 TWD 10 P2 TWD 6 P2 TWD 10 P2 TWDO4 P2 TWD 6 P2 TWD 6 P2 TWD 9 P2 TWD 5 P2 TWD 5 P2 TWD 5 P2 TWD 6 P2 TWD 5 P2 TWDO6 P2 TWD 10 P2. TWD 11 P2 TWD 9 P2 TWD 6 P2 TWD 9 P2 TWD 8 P2 1 TWD 15 P2 TWD 6 P2 TWD 16 P2 TWD 6 P2 TWD 5 P2 TWD 8 P2 TWD 18 P2 TWD 12 P2 TWD 13 P2 TWD 7 P2 TWD 7 P2 TWD 18 P2 TWD 9 P2 TWD 12 LOCATION 010
+0.16 007
-0.41 011
-0.54 011
-0.52 003
-0.26' 009
+0.65 011
-0.29 011
+0.42 007
+0.00 008
+0.00 009
+0.47 003
-0.23 003
+0.00 004
+0.36 004
+0.00 006
+0..31 006
+0.00 006
-0.05 002
-0.26 002
+0.13 003
-0.26 003
+0.16 004
-0.28 004
+0.00 004
+0.41 006
-0.31 006
+0.00 006
+0.36 008
-0.29 008
+0.13 013
-0.31 009
+0.42 007
-0.05 006
-0.31 006
+0.31 012
-0.34 012
-0.34 010
-0.42 0-12
+0.-26 012
-0.52 012
+0.18 012
-0.53 011
+0.18 012
-0.55 012
-0.55 009.
+0.18 007
-0.61 007
-0.60 007
+0.13 007
-0.68 007
+0.21 007-
-0.54 007
-0.52 007
-0.57 007
-0.56 007
+0.18 007
+0.21 007
-0.57 007
-0.57.
007
-0.49 007
-0.50 011
-0.57 010
+0.16 007
-0.44 011 -
-0.49 006
-0.26 007
-0.28 007
+0.10 006 0.28 007
-0.31 009
-0.36 011
-0.31 011
+0.42 004
-0.28 006
-0.31 006
+0.10 008
-0.29 009
-0.34 009
+0.68 012
-0.29 EXT LTE LTE LTE LTE LTE LTE LTE LTE 007 008 009 003 003 004 004 006 006 006 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE' LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTE UTE UTE UTE UTE UTE UTE UTE 007 008 009 003 003 004 004 006 006 006 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE OTE OTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE uTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR-WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL # LEG 92 INLET 90 INLET 90 INLET 92 INLET 118 INLET 118 INLET 118 INLET 118 INLET 9
INLET 9
INLET 9
INLET 9
INLET
.9 INLET 9
INLET 9
INLET 9
INLET 9
INLET 9
INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 6
INLET 9
INLET 10 INLET 16 INLET 16 INLET 16 INLET 18 INLET 0
18 INLET 0
18 INLET 17 INLET 3
16 INLET 18 INLET 162 INLET 4
639 INLET 6
639 INLET 4
639 INLET 70 INLET 3
637-INLET 70 INLET 70 INLET 3
637 INLET 7
637 INLET 70 INLET 70 INLET 70 INLET 90 INLET 92 INLET 7
90 INLET 4
92 INLET 92 INLET 90 INLET 118 INLET 118 INLET 118 INLET 118 INLET 118 INLET 118 INLET 118 INLET 118 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 5
10 INLET PROBE 510OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XP 510XP 510XP 510XP 510XP 510XP 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 51OUL 51OUL 51OUL 510XB 510UL 510XB 510XB 510UL 510UL 510XB 5l0XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:11:42 Component: S/G B Page 23 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 76 2
0.73 1.11 1.71 1.68 1.61 1.37 0.44 1.91 2.74 1.85 0.22 0.60 0.23 0.41 0.28 0.08 0.26 0.34 0.35 0.07 0.26 0.38 1.32" 0.65 0.36 0.33 1.55 1.56 1.17 0.81 1.09 1.14 7.6 4
1.01 0.29 76 5
0.19 76 7
0.14 76 9
0.18 76 15 0.73 2.09 76 16 0.20 0.06 76 20 0.06 76 76 0.15 76 78 0.06 76 80 0.07 76 91 0.09 0.06 76 93 0.11 76 95 0.07 76 103 0.06 76 114 0.07 76 129 0.05 76 130 1.41 0.09 0.14 0.39 0.08 0.17 76 131 0.07 0.09 0.11 0.16 77 1
0.11 0.13 0.17 0o 21 0.08 0.53 0.39 1.48 1.28 0.98 77 2
1.67 0.19 0.22 0.08 0.13 0.33 0.18 0.36 DEG CHN 94 P20 81 P17 103 P6 85 PI1 90 P28 87 P27 129 158 83 P25 87 P26 83 P17 136 P2 130 P2 136 P2 130 P2 133 P2 136 P2 139 P2 141 P2 135 P2 154 P2 139 P2 136 P2 132 P2 138 P2 132 P2 140 P2 80 P8 267 P17 90 PlO 95 P28 102 P25 106 P7 94 P20 137 P2 138 P2 143 P2 150 P2 131 P2 112 150 139 P2 151 P2 149 P2 88 P2 140 P2 140 P2 116 P2 135 P2 143 P2 128 P2 145 P2 140 P2 146 P2 99 126 143 P2 131 P2 132 P2 147 P2 133 P2 134 P2 147 P2.
151 P2 149 P2 117 P2 135 P2 132. P2 138 P2 144 P2 139 P2 131 P2 84 P8 83 P16 77 P7 115 54 134 P2 126 P2 132-P2 141 P2 132 P2 133 P2 133 P2 IND %TW VOL VOL VOL VOL VOL VOL VOL VOL TWD 35 TWD 27 TWD 17 TWD 33 TWD 18 TWD 27 TWD 21 TWD 7 TWD 20 TWD'24 TWD 24 TWD 7 TWD 20 TWD 26 TWD 46 TWD 35 TWD 25 TWD 24 TWD 24 TWD 24 "TWD 20 TWD 15 TWD 19 TWD 19 VOL TWD 21 TWD 11 TWD 9 TWD 11 TWD 30 VOL TWD 16 TWD 5 TWD 5 TWD 13 TWD 5 TWD 6 TWD 8 TWD 5 TWD 10 TWD 4 TWD 5 TWD 7 TWD 5 VOL TWD 8 TWD 12 TWD 25 TWD 7 TWD 14 TWD 6 TWD 7 TWD 8 TWD 12 TWD 10 TWD 11 TWD 14 TWD 17 TWD 8 TWD 31 TWD 26 VOL TWD 21 TWD 17 VOL TWD 11 TWD 13 TWD 5 TWD 8 TWD 17 TWD 11 TWD 18 LOCATION 012 011 009 007 005 004 008 001 002 002 001 001 004 004 008 009 009 010 011-011 012 007 002 003 005 006 003 003 006 006 010
.010 012 012 012 012 012 012 012 012 012 009 007 008 007" 007 007 007 007 007 013 001 007 001 006 007.
007 010 010-011 009 011 003 005 006 007 007.
002 004 004 002 002 011 002 003 003 004 004
+
005 007
-0.32
-'0.34
+0.55
+0.00
+0.00
+0.34
-0.26
+0.00
+0.00
-0.23
+0.00
+0.44
-0.31
+0.39
-0.31
-0.34
+0.62
+0.68
-0.31
+0.39
-0.31
+0.00
+0.00
-0.08
+0.21
+0.13
-0.23
+0.00
+0.00
+0.29
+0.50
+0.60
-0.39
-0.34
-0.37
-0.36
-0.39
-0.52
-0.55
-0.55
+0.13
-0.54
-0.63
+0.13
+0.18
-0.60
+0.21
-0.60
+0.18
-0.59
-0.66
+0.13
-0.34-
+0.44
-0.28
-0.31
+0.13
+0.70
-0.23
-0.29
+0.67
+0.34
-0.23
-0.31
-0.31
-0.26
+0.13
+0.00
-0.08
+0.00
-0.18
+0.00
-0.31
-0.23
-0.26
+0.44
-0.29 0.39
+0.44
-0.29 EXT 012 011 009 007 005 004 008 001 002 002 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 003 003
" 006 006 010
-010
- 012 LTE LTE LTE "LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE
- LTE LTE LTE LTE LTE 007 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 004 002-
- 002 011 LTE LITE LTE LTE LTE LTE LTE EXT 012 011 009 007 005 004 008 001 002 002 UTE UTE UTE UTE UTE UTE UTE UTE rUTE UTE UTE UTE UTE UTE UTE UTE 003 003 006 006 010 010 012 UTE UTE UTE UTE UTE 012-UTE UTE UTE UTE UTE UTE UTE UTE
.UTE UTE UTE UTE UTE 007 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 004 002 002 011 UTE UTE UTE UTE UTE UTE UTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR
- WAR, WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL # LEG 9
INLI 9
INLI 9
INLI 9
INLI
.9 INLI 9
INLI 9
INLI
- 9 INLI
.9 INLI 9
INLI 10 INLI 10 INLI 10 INLI 10 INLI 10 INLI 10 INLI 10 INL}
10 INLi 10 INL 10 INL 10 INL 10 INL LAR 10 INLI 10 INLI 10 INLI 10 INLI 9
INLI 9
INLI 9
INLI 9
INLI 9
INLI 9
INLI 9
INLI 10 INLI 6
INLI 6
16 INML 16 INLE 16 INLE 15 INLE 18 INLE 0
.18 INLE 0
561 INLE 5
639 INLE 3
639 INLE 4
639 INLE 2
639 INLE 4
639 INLE
.3 639 INLE 70 INLE 0
635 INLE 92 INLE 98 INLE 97 INLE 98 INLE 98 INLE 98 INLE 98 INLE 98 INLE 118 INLE 118.
INLE 118 INLE 3
118 INLE 10 INLE 10 INLE 10 INLE 10 INLE 10 INLE 10 INLE 10 INLE 9
INLE 9
INLE 9
INLE 5
INLE 6
INLE 6
INLE 6
INLE 6
INLE 6
INLE 6
INLE 6
INLE ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET T
T T
T T
T T
T T
T T
T T
T T
T T
ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET ET
.T ET ET ET ET ET ET ET ET ET ET ET ZT
- T ZT ET ET PROBE 510XP 510XP 510XP 510XP 510XP 510XP 510XP 510XP 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XP 510XP 510XP 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510UL 510UL 510UL 510UL 510UL 510UL 510UL 510XB 510UL 510XB 510XB 510XP 510XB 510XB 510XB.
510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XP 510XP 510XB 510XB.
510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: 0N52 Repi 01/20/09 02:11:42 Component: S/G B Page 24 of 46 Service Induced Degradation QUERY: u2aga.qry ROW COL VOLTS 0.26 0.20 0.67 0.20 0.09 0.32 77 3
0.10 0.15 0.06 77 5
0.46 1.54 77 8
1.46 0.30 77 10 0.25 0.12 77 11 0.13 0.06 77 13 0.12 77 14 0.28 0.12 77 17 0.15 0.06 77 20 0.05 77 76 0.07 77 110 0.14 77 115 0.13 77 117 0.11 77 118 0.12 77 119 0.14 77 126 0.07 77 131 0.10 77 132 0.13.
0.07 78 1
0.16 0.15 0.12 0.28 0.10 0.13.
0.69 0.16 0.08 0.14 2.98 0.75 78 2
0.08 78 3
1.44 0.09 0.14 0.42 78 4
0.23 0.09 78 5
0.21 0.11
- 78.
7 0.17 78 10 1.54 0.29 78 11 0.16 0.13 0.08 0.07 78 15 0.08 0.25 0.12 78 18 0.07 78 23 0.07 78 78 0.09 0.10 78 92 0.08 78 116 1.42 0".21 0.40
.78 118 0.21 0.17 78 127 0.07 78 131 0.08 0.09 0.06 79 1
0.13 0:14 DEG 137 131 127 135 128 133 143 137 ill 135 91 85 134 142 151 144 152 146 140 141 143 152 149 125 63 140 125 141 145 139 141 139 131 138 139 138 126 140 141 132 134 139 146 87 72 141
- 123, 135 136 136 138 150 138 146 144 121 139 139 147 137 139 118 136 136 149 154 84 131 152 115 134 139 144 129 135 142 151 149 150 133 CHN P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P17 P5 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 Plo P16 P2.
82 P2 P2 P2 P2 P2 P2 P2 P2 P5 P2 P2 P2 P2.
P2 P2 P2 P2 P2 P2 P2 P2 P2 74 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND %*
TWD 1 TWD 1i TWD 2E TWD 1; TWD 6 TWD 1 TWD 1(
TWD 1:
TWD 6 TWD 2 VOL VOL TWD 2(
TWD l' TWD 9 TWD 1' TWD 6 TWD 1(
TWD 1ý TWD 1(
TWD 1, TWD 6 TWD 4 TWD 6 TWD 11 TWD 1(
TWD 9 TWD 9 TWD 1, TWD 5 TWD 8 TWD 1(
TWD 6 TWD 1l TWD 1' TWD 11 TWD 21 TWD 9 TWD 1, TWD 3(
TWD 14 TWD 7 TWD 1, VOL VOL TWD 7 VOL TWD 6 TWD 9 TWD 21 TWD 1E TWD 9 TWD 12 TWD 7 TWD I1 VOL TWD 21 TWD 12 TWD 1C TWD 7 TWD 6 TWD 6 TWD 1 TWDO 9 TWD 6 TWD 6 TWD 8 TWD 9 TWD 7 VOL TWD 1 TWD 2E TWD IE TWD 13 TWD 6 TWD 6 TWD 7 TWD 5 TWD 11 TWD 12 TW 4
2 8
2 7
0 3
9 LOCATION 007 008 o0l 012.
002 009 003 003 006 010.
010 010
- 010, 012 013 010 Oi1 010 012 012 012 007 012 007 012 012 011 012 012 010 Ol 010 006 003 004 007 010 010 012 012 013 004 011 012 010 003 012 004 011 012 012 012 012 013 012 010 010 010 012 013 013 007 012 011 010 012 007 008 007 014 014 014 013 013 006 006 011 007 009 0!il
+0.13
-0.29
-0.31
+0.37
+0.13
+0.44
-0.03
+0.41
-0.34
-0. 31
ý0.29
-0 36
-0.36
-0.44
-0.55
-0. 42
+0.18
-0.44
-0.49
+0.16
-0.55
-0.47
+0.08
-0.
65
-0.55
-0.57
-0.57
-0.55
-0.49
-0.36
-0.31
-0.26
-0.31
-0.23
+0.39
+0.39
-0.29
+0.71
-0.05
+0.39
-0.31
-0.11
-0.31
+0.39
-0.31
-0.23
-0.39
+0.36
-0.34
-0.31
-0.34
+0.34
-0.34
+0.31
+0.26
-0.42
-0.42
-0.41
-0.47
-0..52 1-0.21
-0.41
+0.16
-0.52
-0.55
+0.00
-0.60
-0.60
-0.52
+0.13
-0:60
+0.13
+0.16
-0.60
-0.33
-0.31
+0.37
-0.34.
+0.65
-0.29 EXT EXT LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 010 010 010 010 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 010 010 LTE UTE 012 012 LTE.UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE
.010 1o0
- LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 014 014 LTEUTE LTE UTE LTE.UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL 1
UTIL WAR WAR WAR WAR WAR 5
WAR WAR WAR WAR WAR WAR WAR WAR WAR 0
WAR 0
WAR 0
WAR 4
WAR WAR WAR WAR WAR 0
WAR WAR 5
WAR 10 WAR WAR WAR WAR WAR WAR WAR WAR 3
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR S
WAR WAR WAR WAR WAR.
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 0
WAR 0
WAR WAR WAR 3
WAR WAR 0
WAR WAR WAR WAR WAR WAR WAR WAR 4
WAR 0
WAR WAR WAR 4
WAR WAR 2
CAL # LEG 6
INLET 6
INLET 6
INLET 6
INLET 6
INLET 6
INLET 10 INLET 10 INLET 10 INLET 10 INLET 9
INLET 101 INLET 102 INLET 102 INLET 102 INLET 104 INLET 104 INLET 104 INLET 102 INLET 102 INLET 104 INLET 104 INLET 102 INLET 629 INLET 553 INLET 130 INLET 130 INLET 128 INLET 130 INLET 128 INLET 118 INLET 118 INLET 118 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 10 INLET 9
INLET 9
INLET 10 INLET 5
INLET 6
INLET 6
INLET 6
INLET 10 INLET 10 INLET 6
INLET 6
INLET 102 INLET 103 INLET 104 INLET 102 INLET 102 INLET 102 INLET
.102 INLET 102 INLET 102 INLET 102 INLET 104 INLET 503 INLET 140 INLET 140 INLET 140 INLET 129 INLET.
130 INLET 130 INLET 130 INLET 130 INLET 114 INLET 118-INLET 118 INLET 118 INLET 10 INLET 10 INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
-510XB
.510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510oB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 510XB 510XB 510XP 510XB 510XB.
510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:11:42 Component: S/G B Page 25 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.28 0.14 0.15 0.21 0.09 0.09 0.07 0.77 79 2
0.09 0.09 0.12 0.09 79 3
008 79 4
0.28 0.16 0.08 79 5*
0.26 0.-69 79 6
1.62 0.64 0.13 0.10 0.09 79 7
0.08 0.13 79 9
0.10 79 10 1.73 0.09 0.38 79 12 0.08 79 13 0.08 0.15 0.07 79 14 0.27 79 15 0.09 0.07 79 16 1.94 0.45 79 22 0.08 7*9 97 0.06 0.06 79 115 0.0.6 79 117 0.14 79 118 0.10 79 119 0.12 79 130 0.06 79 11
.0.17 0.06 0.05 79 132 0.11 0.06 0.25 0.17 0.i1 0.21 80
- 1.
0.12 0.09 80 3"
0.98 0.14 0.14 0.40
.80 5
0.22 0.12 0.22 80 7
1.32.
0.33 80
- 8.
0.15 80 10 1.97 0.42 0.07 80 11 1.63 0.38 80 12 0.12 80 13
.0.09 "0.10 80 14 0.06 0.08 80 16 0.09 80 17 0.14 0.18 DEG CHN 140 P2 125 P2 136 P2 131 P2 140 P2 138 P2 153 P2 79 P19 130 P2 140 P2 129 P2 138 P2 128 P2 135 P2 145 P2 108 P2 139 P2 95 P20 118 82 130 P2 138 P2 148 P2 144 P2 137 P2 152 P2 147 P2 87 P5 138 P2 134 P2 144 P2 158 P2 138 P2 144 P2 131 P2 157 P2 144 P2 78 P10 130 P2
.143 P2 108 P2 141 P2 150 P2 119 P2 141 P2 127 P2 138 P2 134 P2 128 P2 94 P2 145 P2 153 P2 138 P2 144 P2 153 P2 132 P2 116 P2 130 P2 11 110 136* P2 i31 P2 133 P2 142 P2 148 P2 141 P2 80-P6 133 P2 146 P2 107 P6 135 P2 146 P2 80 P6 134 P2 148 P2 144 P2 135 P2 150 P2 148 P2 150 P2 128 P2 136 P2 IND TWO TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL VOL TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD-TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD VOL TWD TWD VOL TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW 21 12 13 17 99 7
6 6
7 6
8 16 10 5
20 27 8
7 6
7 11 9
7 24 7
7 12 6
18 8
7 26 6
6 5
5 11 8
10 5
13 5
4 9
5 17 12 9
15 11 8
9 9
20 13 8
13 21 12 26 6
24 10 7
8 6
7 8
11 13 LOCATION 012
-0.29 007
-0.26 003
-0.23 004
-0.28 006
-0.28 006
+0.39 007
+0.39 012
-0.34 002
-0.26 002
+0.41 003
-0.23 007
-0.29 004
+0.36 012
-0.34 013
-0.37 004
-0.29 012
-0.37 012
-0.37 012
-0.42 012
-0.37 012
+0.03 013
+0.34 014
-0.39 013
+0.24 012
+0.29 012
-0.42 010
-0.39 007
+0.26 010
-0.39 010
-0.44 012
+0.18 013
-0.55 014
-0.55 013
-0.60 011
-0.50 011
+0.11 012
-0.57 012
-0.57 012
+0.08 007
+0.21 007
-0.52 006
+0.23 010
+0.18 012
-0.55 013
-0.57 008
-0.41 002
-0.18 005
+0.36 009
-0.41 006
-0.23 008
+0.41 011
-0.31 011
+0.39 001
-0.21 002.
-0.05 004
-0.39 007
+0.37 012
+0.37 010 70.31 011
-0.34 012
+0.37 012
-0.37 013
-0.39 014
-0.37 010
-0.36 010
-0.36 012
+0.26 010
-0.39 010
-0.39 007
-0.42 010
-0.41 010
-0.41 010
-0.42 012
+0.18 012
-0.52 011
-0.47 013
+0.18 010
-0.52 012
+0.13 014
-0.62 EXT LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 012 LTE LTE LTE LTE LTE LTE LTE 010 LTE LTE LTE LTE
.LTE.
LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE 010 LTE LTE 010 LTE LTE 010 LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 012 UTE UTE UTE UTE UTE UTE UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE 010 UTE UTE 010 UTE UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL 10 10 10 10 10 10 9
6 6
6 6
10 6
6 10
.9 5
6 0
6 4
6 6
6 104 0
104 0
104 101 io2 102 102 5
104 7
104 5
-104 102 5
104 1
104
-1:01 102
-102 140 0
140 130 130 128 130 2
114 116 116 116 138 138 138 138 6
138 8
138 10 10 i5 6-6 6i 6
6 6
101 102 104 103 104 2
104 101 102 8
104 102 0
102 4
104 4
.104 4
104 102 102
- LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET-INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
ý510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 516XB 510 XE
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:11:43 Component:
S/G B Page 26 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 80 18 0.09 0.05 80 68 0.16 80 88 0.07 80 112 0.09 80 123 0.04 80 127 0.07 80 130 0.05 80 131 0.11 81 2
0.13 81 3
0.26 0.81 81 4
0.25.
81 5
0.11 0.06 81 7
1.91 0.33 81 8
2.27 0.59 0.21 81 10 0.22 81 13 0.07 81 14 0,13 81 17 0.09 0.05 0.06 81 112 0.09 81 118 0.12 81 119 0.09 81 121 0.10 81 124 0.09 81 125 0.07 81 128 0.35 1.60 81 130 0.08 81 131 0.12 81 132 0.15 0.07 82 1
0.33 0.96 82 2
0.12 0.09.
0.19 82 3
0.10 82 4
0.24 82 5
0.23 82 8
0.46 0.11 1.59 82 12 0.08 82 15 0.12 82 18 0.08 82 31 0.06 82 75 0.05 82 103 0.08 82 111 0.07 82 113 0.17 82 114 0.11 82 131 0.23 83 1,
0.46 0.13 0.41 1.27 1.32 83 2
0.30 0.32 83 5
0.09 0.13 83 6
0.15 0.31 83 7
0.38 0.24 1.57 83 8
3.51 0.66
- 83 10 2.69 0.08 0.48 0.13 0.10 DEG CHN 148 P2 143 P2 127 P2 131 P2 144 P2 157 P2 157 P2 142 P2 136 P2 143 P2 138 P2 83 P20 133 P2 144 P2 153 P2 114 P6 138 P2 79 P6 128 P2 143 P2 141 P2 146 P2 142 P2 148 P2 141 P2 146 P2 150 P2 140 P2 151 P2 149 P2 148 P2 135 P2 134 P2 113 86 142 P2 138 P2 146 P2 145 P2 135 P2 83 P22 142 P2 147 P2 132 P2 138 P2 139 P2 142 P2 132 P2-146 P2 85 P4 153 P2 136 P2 143 P2 143 P2 131 P2 146 P2 129 P2 132 P2 129 P2 145 P2 135 P2 147 P2 129 P2 88 P22 92 P22 130 P2 135 P2 138 P2 149 P2 146 P2 135 P2 137 P2 143 P2 86 P3 75 P2 128 P2 77 P1 130 P2 130 P2 150 P2 144 P2 IND %TW TWD 8 TWD 5 TWD 10 TWD 6 TWD 6 TWD 3 TWD 6 TWD 5 TWD 8 TWD 8 TWD 20 VOL TWD 14 TWD 10 TWD 6 VOL TWD 23 VOL TWD 32 TWD 15 TWD 16 TWD 7 TWD 10 TWD 8 TWD 5 TWD 5 TWD 7 TWD 9 TWD 7 TWD 8/
TWD 7k TWD 6 TWD 23 VOL TWD 6 TWD 10 TWD 11 TWD 5 TWD 24 VOL TWD 11 TWD 8 TWD 16 TWD 6 TWD 19 TWD 13 TWD 27 TWD 9 VOL TWD 7 TWD 10 TWD 7 TWD 5 TWD 5 TWD 6 TWD 5 TWD 12 TWD 9 TWD 16 TWD 29 TWD 11 TWD 27 VOL VOL TWD 16 TWD 17 TWO 9 TWD 11 TWD 9 TWD 17 TWD 24 TWD 17 VOL VOL TWO 33 VOL TWD 6 TWD 28 TWD 10 TWO 8 LOCATION 010
-0.50 007
-0.49 007
-0.63 007
+0.21 009
-0.47 011
+0.24 013
-0.47 001
+0.15 006
-0.28 012
+0.39 012
-0.34 012
-0.34 012
-0.34 012
-0.34 012
+0.36 010
-0.36 010
-0.36 010
-0.39 010
-0.39 012
-0.39 012
-0.44 010
-0.47 014
-0.57 010
-0.49 007
-0.49 011
+0.11 007
-0.52 009
-0.44 012
-0.49 012
-0.50 013
-0.55 011
+0.26 013
-0.44 013
-0.44 011
-0.34ý 002
-0.21 011
+0.39 006
-0.28 012.
-0.
2 9 012
-0.29 013
-0.34 009
+0.70 012
-0.32
'013
-0.37 012
-0.34 012
-0.37 010
-0.39 014
-0.42 010
-0.39 012
-0.50 012
-0.52 010
-0.52 011
-0.03 008
+0.16 007
+0.13 007
-0.52 011
-0.63 012
-0.60 011
+0.42 012
-0.29 012
+0.39 013
-0.31 013
-0.31 012
-0.29
.011
-0.31 012
-0.31 012
-0.37 013
-0.39 013
-0.42 012
-0.39 010
-0.39 012
-0.37 010
-0.39 010
-0.36 010
-0.36 010
-0.39 004
-0.31 010
-0.39 012
-0.42 011
+0.23 EXT EXT LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE 010 010 LTE UTE 010 010 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE tTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 013 013 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 010 010 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 013 013 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 010 010.
010 010.
LTE UTE 010 010 LTE UTE LTE UTE LTE UTE LTE UTE UTIL 1
UTIL WAR 5
WAR 3
WAR WAR WAR 5
WAR WAR 3
WAR WAR 4
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 3
WAR 3
WAR WAR WAR WAR WAR WAR 4
WAR WAR WAR 4
WAR WAR WAR 4
WAR WAR WAR WAR WAR 0
WAR 0
WAR WAR WAR WAR WAR WAR 0
WAR 2
WAR WAR WAR 3
WAR 5
WAR WAR WAR WAR WAR--
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 3
WAR WAR WAR WARý WAR WAR WAR WAR WAR WAR 6
2 CAL #
104 104
- 162, 140 555 128 114 116 118 6
10 9
6 10 10 103 104 101 102 102 102 104 102 104 104 104 128 128 130 130 128 130 114 113 114 116 118 118 10 9
.10 10 10 6
10 6
96 96 95 104 102 104 102 629 553 128 128 130 118 10 10 10 9
9 66 10 10 6
6 96 96 95 93 94 93 94 94 94 94 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510UL 51OXB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 51DXP 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
.510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB.
510XB 510XP 510XB 510XB 510XB 510XB 510UL 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XP 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:43 Component: S/G B Page 27 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 83 11 0.10 0.18 83 15 0.17 0.10 83 20 0.12 0.04 83 112 0.11 83
.113 0.06 83 114 0.12 83 117 0.26 83 121 0.20 83 124 0.04 83 131 0.07 0.09 0.04 0' 06 84 1
0.27 0.77 84 3
0.11 84 4
0.11 0.17 84 5
1.31 0.44 84 7
1.28 0.32 0.04 0.11 84 9
0.10 0.11 0.06 84 13 0.06 0.07 0.07 84 18 0.09 84 30 0.08 84 70 0.09 84 87 0.13 84 90 0.06 0.06 84 111 0.07 84 116 0.24 0.10 84 118 0.14 0.07 84 123 0.13 0.09 0.16 84 131 0.23 0.17 0.16 0.12 0.08 85 1
0.14 0.25 85 2
0.13 85 3
0.21 85 4
0.12 85 5
0.34 0.11 85
- 7.
0.11 85 11 0.09 85 18 0.15 0.09 85 19 0.08 85 21 0.10 85 46 0.11 85 112 0.10 85 113 0.15 85 116 0.10 85 120 0.08 85 121 0.09 85 123 0.09 85 129 0.15 85 130 0.15ý 0.10 86 3
0.20
- 86.
4 0.28 0.98 86 5
0.23 86 6
0.31 DEG CHN 154 P2 148 P2 144 P2 135 P2 130 P2 148 P2 115 P2 124 P2 127 P2 142 P2" 142 P2 94 P2 146 P2 140 P2 131 P2 99 P2 142 P2 88 P23 138-P2 148 P2 138 P2 117 58 128 P2 82 P12 135 P2 139 P2 144 P2 148 P2 151 P2 153 P2 144 P2 156 P2 143 P2 153 P2 143 P2 129 P2 128 P2 145 P2 127 P2 151 P2 145 P2 145 P2 148 P2 146 P2 139 P2 147 P2 145 P2 138 P2 142 P2 147 P2 145 P2 112 P2 142 P2 137 P2 137 P2 137 P2 130 P2 133 P2 140 P2 155 P2 138 P2 125 P2 144 P2 129 P2 109 P2 131 P2 137 P2 129 P2 126 P2 145 P2 143 P2 146 P2 107 P2 138 P2 130 P2 129 P2 137 P2 91 P23 131 P2 137 P2 IND TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD VOL TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD
%TW LOCATION 8
012
+0.21 14 014
-0.55 13 012
-0.53 8
012
+0.13 10 010
-0.52 4
012
+0.03 8
012
-0.45 5
009
+0.21 10 012
-0.60 18 009
+0.21 15 012
-0.47 4
011
+0.13 6
001
+0.44 8
006
+0.36 4
006
-0:23 5
001
-0.03 20 012
-0.32 012
-0.32 7
011
-0.37 10 011
-0.34 14 012
+0.37 010
-0.36 21 010
-0.34 012
-0.36 21 012
-0.36 3
007
-0.36 9
014
-0.44 8
012
-0.42 8
013
-0.47 5
014
-0.47 5
010
-0.47 6
011
-0.44 6
013
-0.54 8
010
-0.52 7
011
-0.05 6
007
-0.66 9
007
-0.60 6
006
+0.18 5
007
-0.57 6
009
-0.47 17 010
+0.16 8
013
+0.10 12 010
+0.60 6
011
+0.13 10 010
-0.
4 2 7
012
-0.42 12 013
-0.52 16 007
-0.31 13 007
+0.03 12 011
+0.36 9
009
+0.65 6
008
-0.21 13 011
-0.31 19 012
-0.29 11 013
-0.34 12 012
-0.31 11 010
-0.29 18 010
-0.34 7
012
+0.34 9
013
-0.47 7
012
+0.23 12 012
-0.58 8
011
+0.10 7
012
-0.57 8
012
-0.62 8
009
-0.62 8
011 0.63 12 009
-0.44 8
012
-0.55 6
012
-0.50 8
011
+0.18 8
011
+0.26 12 010
+0.68 12 011
-0.31 8
006
-0.28 12 012
-0.31 21 012
-0.34 012
-0.37 13 010
-0.34 21 010
-0.36 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE 010 LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE
- LTE, LTE LTE
- LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE EXT UTIL UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 012 WAR UTE WAR UTE WAR UTE WAR 010 WAR UTE WAR 012 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE.
WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE.
WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR.
UTE WAR 012
.WAR UTE WAR UTE WAR UTIL 2
CAL #
96 96 96 96 94 94 128 130 152 130 130 128 114 114 114 4
114 10 9
0 6
10 10 5
6 93 94 94.
0 94 94 94 2
94 0
94 0
94 0
94 96 94 162 4
559 140 2
140 0
553 152 152 4
130 4
130 128 128 128 118 118 118 118 5
118 10" 10 10 6
5 10 6
6 94 5
94 96 0
96 0
94 94 4
531 128 152 128 128.
4 130 130 114 116 4
116.
6 10 9
6 96 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XP 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
.510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:43 Component: S/G B Page 28 of 46 Attachment. 2 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 1.05 86 7
0.07 0.14 0.08 0.22 86 8
0.15 86' 10 0.16 86 13 0.14 0.12 86 14 0.09 86 21 0.09 86 78 0.05 86 94 0.06 86 97 0.06 86 103 0.06 86 110 0.14 86 113 0.16 86 114 0.09 86 116 0.07 0.16 86 119 0.09 86 126 0.10 86 130 0.07 86 131 0.11 87 1
0.13 87 2
0.16 87 3
0.33 0.15
-0.10 87 4
0.43 0.18 1.59 87 5
0.26 0.23 87 6
0.21 87 7
0.07
-0.33 0.30 1..56 1.50 87 8
0.07 87 10 0.24 87 11 0.06 87 12 0.07 87 14 0.16 87' 16 0.07 87 19 0.14 87 20 0.10.
0.08 87 106 0.09 87 109 0.10 87 11 0.09 87 113 0.17 0.09 0.04 87 115 0.13 87
-118 0.09 87 119 0.19 88-2 0.24 0.13 0.08 88 4
0.50 2.04 88 5
0.32 0.10 88 6
0.32 0.15 0.19 1.13 88 7
0.24 88 8
0.19 0.11i 0.07 88
-9 0.12 0.09 0.07 88 10 0.12 88 11 0.09 0.27 88 16 0.21 DEG CHN 94 P5 139 P2 140 P2 141 P2 139 P2 144 P2 151 P2 140 P2 150 P2 149 P2
.154 P2 131 P2 135 P2 123 P2 138 P2 119 P2 123 P2 157 P2
.151 P2 137 P2 153 P2 150 P2 147 P2 153 P2 137 P2 143 P2 137 P2 138 P2 142 P2 130 P2 141 P2 85 P27 135 P2 132 P2 140 P2 143 P2 139 P2 140 P2 91 P16 84 P20 149 P2 142 P2 156 P2 147 P2 136 P2 127 P2 143 P2 143 P2 137 P2 144 P2 134 P2 138 P2 142 P2 139 P2 157 P2 141 P2 150 P2 145 P2 138 P2 142 P2 144 P2 131 P2
.84 P26 129 P2 144 P2 1-39 P2 146 P2 145 P2 83 P7 139 P2 151 P2 150 P2 150 P2 136 P2 142 P2 143 P2 142 P2 136 P2 132 P2 143 P2 IND VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD VOL VOL TWD TWD TWD TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD
-TWD TWD TWD
%TW LOCATION 010
-0.36 5
007
-0.39 11 010
-0.34 7
012
+0.31 16 012
-0.42 12 012
-0.42 12 012
+0.21 11 012
+0.18 10 - 011
-0.47 8
010
-0.49 7
011
+0.05 5
008
+0.21 6
007
+0.18 5
007
+0.10 5
009
-0.54 9
011 A0.62 12 012
-0.60 7
009
+0.21 6
006
-0.39 12 012
-0.57 7
011
-0.52 8
012
-0.36 6
01l
+0.37 9
011
+0.36 11 012
-0.31 14 010
-0.29 18 012
-0.31 9
013
-0.37 6
014
-0.37 28 010
-0.34 15 012
-0.31 010
-0.34 15 010
-0.31 13 013
-0.39 15 010
-0.36 6
012
-0.42 21 013
-0.44 20 014
-0.42 013
-0.44 014
-0.45 6
011
-0.44 17 014
-0.49 5
010
-0.42 6
010
-0.47 12 012 10.52 6
010
-0.54 11 012
+0.08 8
011
+0.05 7
012
+0.10 6
010
+0.08 7
011
-0.63 7
009
-0.47 12 009
-0.47 7
010
+0.03 4
011
+0.16 10 012
-0.55 8
011
+0.18 14 012
-0.47 19 011
-0.29 11 012 0.29 7
012
+0.37 30 010
-0.31, 010
-0.29 17 010
-0.34 7
014
-0.39 21 010
-0.34 11 012
+0.31 14 012
-0.37 010
-0.34 17 012
-0.39 14 012
- +0.26 9
012
-0.39 6
011
-0.34 10 010
-0.36 7
011
-0.41 6
011
+0.26 10 010
-0.39 7
012
-0.21 19 012
+0.21 15 007
-0.47 EXT EXT UTIL 1
010 010 WAR LTE UTE WAR LTE UTE WAR LTE.UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE-WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 010 010 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR
- 013 013
-WAR 014 014 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR-LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTEUTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 010 010*
WAR-LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 010 010 WAR LTE UTE WAR LTE UTE WAR LTE UTE.
WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR UTIL 2
CAL #
95 94 94 94 0
94 96 7
96 94 0
94 96 5
501 3
140 140 140 0
553 5
555 152
- 4 154 152 152 4
128 130 116 118 5
- 10 5
10 6
6 6
10 10 9
6 6
94 96 96 96 95 95 0
94 94 96 94 94 4
94 96 94 94 0
555 128 6
553 128 128 128 128 4
130 152 10 10 10 0o 9
6
.0 6
96 96 0
96 95 0
94 96 0
96 0
96 94 4
94 4
94 96 94 94 96 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET
-INLET INLET INLET INLET INLET INLET INLET.
INLET INLET PROBE 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 510XB 510XB 51OUL 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 51OXB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:43 Component: S/G B Page 29 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 88 18 0.07 88 20 0.06 88 21 0.10 88 88 0.08 88 91 0.09 88 111 0.07 0.22 0.09 88 114 0.08 88 115 0.10 0.17 88 116 0.09 88 117 0.18 88 119 0.13 88 120 0.07 88 121 0.07 0.10 0.06 88 122 0.09 88 127 0.11 88 130 0.10 0.09 89 1
0.18 0.27 0.86 89 2
0.06 0.21 0.11 89 3
0.31-0.09 89 4
0.58 0.25 1.79 89 5
1.85 0.60 0.14 89 6
0.12 89 7
0.58 0.06 2.08 89 8
0.08 89 10 0.08 0.12 89 1i 0:07 0.14 0.18 89
.14 0.06 89 41 0.07 89 67 0.06.
89 68 0.13 89 70 0.10 89 81 0.12 89 82 0.08 89 112 0.11 89 113 0.10 89 114 0.12 89 115 0.19 89 117 0.09 0.11 0.06 89 118 0.08 89 122 0.06 89 123 0.09-0.06 89 129 0.06..
89 130 0.07 0.06 90 1
0.37 0.23 1.28 90 2
0.10 0.13 90 3
0.18 0.13 0.34 1.20 90 4
0.18 90 5
0.42 0.34 0.08 DEG 147 156 106 138 110 158 142 112 141 120 146 147 139 138 154
- 124, 148 136 137 133 136 143 134 135 92 135 135 142 134 145 133 138 87 112 128 150 145 136 147 79 151 153 133 135 133 137 144 135 139 123 122 137 132 139 135 138 140 153 146 149 158 140 150 156 148 128 147 134 137 95 127 144 131 139 135 94 132 136 140 157 CHN P22 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2.
P2 P2 P2 P2 P2 P2 P2 P23 P2' P2 P2 P2 P2 P2 P2 P25 58 P2 P2 P2 P2 P2 P12 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P26 P2 P2 P2 P2 P2 P16 P2 P2 P2 P2 IND TWO TWD TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL VOL TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD.
TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD
%TW 65 7
7 7
6 15 7
7 9
13 8
13 9
6 6
8 5.
7 9
8 8
15 20 6
17 10 17 6
33 19 26 8
10 31 5
7 7
10 6
11 13 5
6 5
10 8
10 7
9 9
10 15 8
10 5
7 5
8 5
5.
6 6
25 18 7
8 15 12 24 11 25 22 7
LOCATION 012
+0.05 012
+0.13 012
-0.58 011
-0.73 009
-0.6,0 009
-0.47 013
-0.71 012
-0.63 010
+0.13 011
-0.60 012
-0.55 010
+0.16 010
+0.16 012.'
.- 0.50.
012
-0.49 011
+0.21 012
-0.47 012
+0.21 006
-0.34 012
-0.34 007
-0.28 007
+0.08 010
-0.26 013
-0.34 013
-0.34 011
-0.31 012
+0.39 013
-0.34 010
-0.31 013
-0.37 012
-0.31 013
-0.37 012
-0.31 010
-0.34 010
-0.34 012
-0.34 010
-0.34 012
-0.39 014
+0.26 012
-0.39 012
+0.26 011
-0.44 010
-0.39 010
-0.42 013
-0.55
.014
+0.21 007
-0.41 010
-0.67 008
-0.60 007
-0.65 007
-0.65 006
+0.13 008
-0.65 012
-0.59 009
-0.46 012
-0.56 012
-0.54 009
-0.44 011
-0.54 011
+0.10 011
-+0.20 012
-0.44 011
+0.28 012
-0.41 011
+0.36 007
-0.31 007
+0.10 011
-0.29 012
-0.32 011
-0.29 012
-0.31 013
-0.39 010
-0.31 012
-0.08 012
+/-0.37, 012
+0.34 010
-0.36 010
-0.34 012
-0.39 013
-0.44 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 013 LTE LTE LTE LTE LTE LTE LTE 012 010 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE EXT DIE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 013 UTE UTE UTE UTE UTE UTE UTE 012 010 UTE UTE UTE UTE UTE 012 UTE UTE UTE
.UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 011 UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL #
96 3
94 4
503 140 4
.557 128 128 128 4
130 152 152 4
130 152 128 3
130 4
152 5
152 4
152 130 3
114 116 116 10 10 9
10 10 10 6
6 10 10 9
5 6.
0 6
0-94 96 0
96 95 q4 94 4
94
.96 96 96 4
94
.114 0
629 152 6
629 140 4
557 4
132 5
134 132 134 -
0 134 5
134 3
134 132 0
132 134 134 114,.
116 116 10 10 9
6 6
10 10 10 9
6 96 96 96 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 51OUL 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXE 510XB 510UL 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
- 510XB, 510XB 510XP 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510KB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:43 Component: S/G B Page 30 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 1.60 1.16 90 6
0.26 0.11 0.16 90 7
0.17 90 8
1.50 0.30 0.16 0.17 90 9
0.10 0.19 90 10 0.07 0.10 90 12 0.06 0.07 90 13 0.16 0.12 0.11 90 87 0.04 90 109 0.07 90 11 0.08 0.25 90 113 1.33 0.30 0.10 90 114 0.13 90 115 1.44 0.44 0.10 0.10 90 119 0.10 90 123 0.09 90 124 0.06 0.06 90 125 0.09 0.06 90 127 0.08 0.09 90 128 0.17 0.09 0.07 90 129 0.10 0.09 0.12 91 1
0.09 0.26 0.78 91 5
1.21 0.40 91 6
0.25 0.10 0.08 0.06 91 7
0.42 0.20 0.30 1.73 1.35 91
.9 0.19 0.27 91 10 0.07 0.08 91 11 0.21 91 14 0:08 91 15 0.08 91 17 0.14 0.09 91 74 0.11 91 11i0 0.09 91 112.
0.07 91 113 0.12
- 91.
114 0.13 0.09 0.14 91 115 0.09 91 116
.0.09 0.21 0.14 91 118 0.15 DEG 91 95 133 142 141 153 79 136 140 144 150 145 128 154 148 154 143 147 141 155 152 133 129 82 138 149 140 80 131 156 132 152 146 155 140 134 109 149 145 112 139 148 149 149
'45 142 137 ill 116 138 138 140 154 129 135 148 139 86 92 138 146 145 141 145 137 157 140 151 120 136 158 133 151 119 143 146 138 146 151 134 CHN P5 P12 P2 P2 P2 P2 P12 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2P2 P13 P2 P2 P2 P14 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2-P2 P2 P2 P2 P2 P2 P2 P2 134 78 P2 P2 P2 P2 P2 P2 P2 P2 P13 P17 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 P2 IND VOL VOL TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWDO TWD TWD TWD VOL VOL TWD TWD TWD
-TWD TWD TWD TWD TWD VOL VOL TWD TWD TWD TWD-TWD TWD TWD TWDO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW LOCATION 010
-0.34 012
- -0.37 18 010
-0.34 9
011
+0.29 12 012
+0.29 13 012
-0.39 012
-0.42 20, 012
-0.42 12 012
+0.26 13 014
-0.44 8
010
-0.39 14 012
-0.42 6
012
+0.23 8
012
-0.47 5
010
-0.44 6
011
-0.44 12 012
-0.50 10 012
+0.16 9
011 0.44 3
011
-0.08 6
009
-0.49 7
009
-0.44 18 014
-0.67 009
-0.46 21 009
-0.46 9' 009
+0.21 10 009 y0.46 009
-0.44 27 009
-0.44 9
010
+0.15 9
011
-0.56 9
012
-0.46 8
012
-0.36 5
012
-0.38 5
011
-0.41 8
012
-0.33 6
008
+0.36 7
013
-0.44 8
013
+0.26 13 010
+0.73 7
011
+0.36 6
006
+0.36 8
006
+0.36 8
008
+0.44 10 009
+0.62 8
012
-0.29 20 012.
+0.39 012
+0.37 012
-0.39 20 012
-0.37 17 010
-0.31i 8
012
-0.36 6
013
-0.46 5
012
+0.31 25 012
-0.42 15 012
+0.29 20 013
-0.42 012
-0.42 013
-0.42 14 011
-0.39 18 012
+0.23 5
012
+0.23 7
013
-0.54 15 012
-0.47 7
011
+0.23 6
010
-0.47 11 014
-0.60 7
014
+0.03 8
007
-0.62 7
009
-0.49 6
009
-0.46 10 009
-0.46 10 009
-0.44 7
012
-0.57 11 011
-0.57 8
012
-0.54 7
009
-0.46 16 009
+0.23 11 012
-0.54 12 009
-0.39 ExT EXT UTIL 1
010 010 WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR tTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 009 009 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 009 009 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTEUTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR 013- 013 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTEDUTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR UTIL 2
CAL #
95 95 94 94 94 96 93 94 94 94 96 96 94 2
94 4
94 4
94 96 96 2
96 140 132.
132 132 133 134 134 132 133 134 134 0
134 134 134 132 0
132 134 4
134 116 116 114 114 3
114 116 116 116 14 14 13 5
6 94 94 94 3
94 96 96 96 95 95 96 96 94 0
94 96 94 96 96 96 5
559 0
553 3
132 134 132 132 7
132 0
134 132 132 0
132 132 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET-INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XP 510XP 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 51OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510xP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB-510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510X B 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:44 Component: S/G B Page 31 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.14 91 119 0.06 91 121 0.15 91 124 0.21 91 129 0.13 0.06 91 130 0.06 0.14 0.10 0.08 0.06 92 4
0.19 0.11 92 5
0.06 92 6
1.82 2.34 0.16 0.36 0.14 0.63 92 7
0.19 0.12 92 8
0.06 92 10 0.10 92 12 0.07
- 0. 08 92 15 0.07 92 i02 0.06 92 110 0.13 92 112 0.19 0.12 92 113 0.13 92 114 0.10 92 115 0.14 92 116 0.07 92 118 0.10 92 120 0.08 92 126 0.08 93 3
0.09 0.31 0.13 0.99 93 4
0.14 0.10 93 5
0.07 0.19 93 6
1.69 0.42 0.11 0.13 93 7
0.10 0.08 0.15 0.14 93 8
0.13 0.26 0.08 93 9
0.09 0.12 93 13 0.06 93 15 0.11 0.08 93 90 0.08 93 111 0.11 93 113 0.07 93 114 0.16 93 116 0.05 93 117 0.20 0.09 93 119 0.08 93 120 0.17 0.06 93 121 0.20 93 123 0.09 93 124 0.05 93 125 0.15.
0.14 0.05 0.06 94 1
0.11 DEG 145 152 140 146 144 148 138 75 149 134 146 129 145 148 83 79 139 137 144.
130 143 151 147 148 140 142 146 138 96 135 147 148 124 142 137 141 142 140 140 138 147 86 146 141 136 145 83 135 134 146 154 153 146 139 141 142 135 151 155 138 148 155 130 100 153 149 139 140 153 147 141 148 144 149 151 143 143 152 156 144 CHN IND P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P16 VOL P12 VOL P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P25 VOL P2 TWD P2 TWD P2 TWD P2 TWD P7 VOL P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD
%TW 11 6
12 16 10 5
5 12 8
7 5
11 7
5 12 23 11 32 14 9
5 8
5 7
6 5
11 14 10 11 8
11 6
9 7
6 8
22 11 9
6 6
14 25 9
10 8
7 11 11 10 18 7
7 10 59 6
7 9
6 13 5
15 8
7 13 5
16 8
5 11 11 5'
5 10 LOCATION 012
+0.21 012-
-0.49 009
-0.44 012
-0.36 009
+0.65 011
+0.37 009
-0.34 010
+0.70 011
+0.44 007
-0.34 007
+0.08 010
-0.31 014
-0.39 010
-0.34 014
-0.39 012
-0.18 010
-0.36 014
-0.39 014
+0.31 012
-0.18 010
-0.36 012
+0.26 010
-0.36 011
-0.46 014
-0.49 010
-0.41 012
+0.16 007
+0.13 012
-0.62 013
-0.65 014
+0.03 009
-0.46 012
-0.57 009
-0.46 009 r0.44 009
-0.41 009
-0.41 008
+0.41 010
.- 0.34 012
-0.34 013
-0.37 012
-0.34 012
-0.34 014
-0.39 010
-- 0.39 012
-0.37 010
-0.34 010
-0.34 012
+0.31 012
-0.39 012
-0.39 012
+0.26 014
-0.45 014
+0.26 010
-0.36 012-
+0.26 012
-0.16 010
-0.39 012
-0.45 011
+0.21 012
+0.16 010
-0.49 009
-0.59 012
-0.57 009
-0.46 009
-0..46 009
-0.44 009
-0.46 012
-0.49 012
-0.46 009
-0.44 012
-0.41 012
-0.41
.012
-0.36 011
-0.39 009
-0.39 012
-0.34 012
+0.34 011
+0.26 007.
+0.37 EXT LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 014 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE 010 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 014 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE 010 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE.
UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR.
WAR WAR UTIL 2
CAL #
132 0
134 134 132 114 114 116 116 116 3
116 116 6
6 96 93 93 94 94
,94 94 96 96 4
94 94 94 2
94 96 132 132
.132 132 134 132 134 4
132 132 132 114 10 10 5
10 9
6 6
96 96 93 94 94 5
94 96:
96 96 96 94 94 6
94 96 96 3
96 96 96 140 0
134 134 132
- 3.
-132 134 134 o0 134 132 4
132 134 134 5
132 114 114 114 114 14 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET' INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXB 510XB
.510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 50XB 510XB 51OXE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB "50XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:11:44 Component: S/G B Page 32 of 46 Service QUERY: u2sga.qry Induced Degradation ROW COL VOLTS 0.07 0.19 0.35 0.72 94 2
0.19 94 3
0.13 94 4
.1.63 0.54 94 6
0.23 0.17 94 7
0.21 0.22 94 8"
0.15 94
.9 0.07 94 10 0.07 94 11 0.06 94 16 0.07 94 17 0.09 94 21
- 0. 11 94 60 0.08 0.13 0.11 94 91 0.09 94 114 0.08 0.12 94 117 0.07 0.15 94 118 0.16 0.05 94 119 0.08 94 120 0.09 94 121 0.09 94 123 0.13 0.10 94 128 0.07 0.15 94 129 0.12 0.11 0.09 0.16 0.06 95 1
0.28 0.59 0.17 0.50 1.38 95 2
0.17 95
.3
.0.33 1.f5 95 4
0.13 0.09 95 5
0.10 95 6
0.21 0.09 95 7
0.11 0.21 95 8
0.09 0.09.
95
- 9.
0.09 95 10 0.15 0.06 0.07 95 11-0.28 0.14 95 12 0.05 95 16 0.15 0.10 95 53 0.05 95 79 0.05 95 93 0.09 95 95 0.13 95 100 0.13 95 103 0.08 95 110 0.14 95 115 0.09 0.009
- 95.
117 0.11 0.10 0.08 95 120 0.11 DEG 142 134 131 123 137 140 114 133 140 148 141 142 143 148 150 156 152 141 133 142 146 128 99 150 148 131 139 145 144 145 140 141 150 153 131 138 145 141 150 140 120 139 129 147 134 113 141 137 83 146 147 148 142 138 145 141 135 144 155 141 146 134 139 146 151 149 145 122 146 ill 122 139 150 134
'133 143 148 126 154 144 CHN IND P2 TWD P2 TWD P2 TWD 86 VOL P2 TWD P2 TWD 78 VOL P2 TWD P2 TWD P2 TWD P2 TWO P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD 86 VOL 118 VOL P2 TWD P2 TWD P24 VOL P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 "TWD
%TW 6
16 24 11 11 24 16 13 15 16 11 6
6 5
6 7
9-7 10 9
8 79 6
12 12 5
7 78 9
6 12 10 9
8 13 5
20 33 14 10 24 8
6 8
15 7
9 15 8
8 8
11 5
5 19 11 4
11 8
4 5
8 11 10 7
12 7
8 9
8 7
10 LOCATION 008
-0.29 011
-0.26 012
-0.29 012
-0.29 012
-0.29 010
-0.31 012
-0.39 012
-0.34 012
-0.36 013
-0.44
.010
-0.36 013
-0.44 014
-0.44 010
-0.36 013
+0.26 010
-0.42 010
-0.49 011
-0.55 012
-0.62 008
+0.18 008
-0.47 010
-0.68 009
-0.59 009
-0.44 012
-0.'52 006
+0.31 009
-0.41 009
-0.41.
013
+0.13 009
-0.44 009
-0.44 009
-0.41
- 012
-0.39 012
+0.31 008
+0.44 009
+0.62 006
+0.36 007
-0.28 007
+0.08 013.
-0.34 009
-0.39 012
-0.29 013
-0.34 015
+0.62 012
-0.26 013
-0.39.
012
-0.31 012
-0.31 012
-0.31 012
-0.34 012
+0.34" 010
-0;36 012
-0.36 010
-0.34 010
-0.36 012
-0.39 010
-0.36 012
+0.26 011
-0.42 014
+0.26.
014
-0.52 010 70.36 014
-0.50
- 010,
-0.42 010
-0.44 009
-0.49 010
-.0.49 008
+0.16 008
+0.18 009
-0.57 009
-0.59 009
-0.54 010
+0.05.
014
-0.-65 012
.- 0.49 009
-0.41 009
-0.44 014
-0.57 014
+0.16 009
-0.41 EXT LTE LTE LTE 012 LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE.
LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 012 013 LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTIL 1
UTIL 2
UTE WAR UTE WAR UTE WAR 012 WAR UTE WAR UTE WAR 012 WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 4
UTE WAR UTE WAR
.3 UTE WAR' UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR.
UTE WAR UTE WAR UTE WAR 4
UTE WAR 3
UTE WAR UTE WAR 3
UTE-WAR UTE WAR 4
UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 012 WAR 013 WAR UTE WAR UTE' WAR 012 WAR UTE WAR UTE WAR UTE WAR -
UTE WAR UTE WAR 6
UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 0
UTE WAR 3
UTE WAR UTE WAR 6
UTE WAR 3
UTE WAR UTE WAR UTE-WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR
'3 UTE WAR.
UTE WAR UTE WAR UTE WAR 4
CAL 14 14 14 13 12 10.
5 69 94 94 96 96 94 96 94 96 94 96 94 152 152 152 140 132 132 134 134 132 132-134 132 134 134 134 114 114 116 116 116 116 116 14 14 14 13 13 12 10 9
6 6
96 94 94 96 96 94 94 96 94 94 94 96 96 94 94 94 114 140 140 140 132 132 134 132 132 132 132 132 134
- LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET
-INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XP 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XP
- 510XP 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXB 510XB 510XB
.510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name:
ONS2 Repi 01/20/09 02:11:44 Component: S/G B Page 33 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS DEG CHN 121 2
4 6
7 8
9 10 11 52 62 70 76 79 89 117 118 121 122 123 2
4 5
6 7
8 9
19 51 99 112 121 122 1
3 4.
7.
8 9
~11 63 78 98 99 110 115 120 0.09 0.50 1.44 0.21 0.27 0.09 0.22 0.10 0.06 0.13 0.11 0.13 0.06 0.08 0.15 0.11 0.06 "0.06 0.09 0.06 0.07 0.09 0.06 0.07 0.09 0.04 0.09 0.05 0.17 0.11 0.07 1.48 0.33 0.06 0.11 0.31 0.92 0.09 0.12 0.22 0.07 0.55 2.11 1.58 0.36 0.11 0.23 0.18 0.05 0.06 0.04 0.04 0.11 0.07 0.14 0.06 0.07 0.24 0.14 0.14 0.41 0.93 0.27 0.07 0.16 0.09 0.09 0.18 0.08 0.06 0.17
.0.07 0.13 0.06 0:'07 0.12 0.08 0.07 0.07 0.05 140 P2 137 P2 126 78 144 P2 134 P2 137 P2 134 P2 146 P2 143 P2 148 P2 155 P2 141 P2 151 P2 151 P2 148 P2 133 P2 108 P2 132 P2 126 P2 113 'P2 141 P2 118 P2 143 P2 50 P2 100 P2 137 P2 111 P2 137 P2 142 P2 105 P2 152 P2 80 P11 138 P2 159 P2 142 P2 136 P2 130 142 141 P2 138 P2 143 P2 141 P2 135 P2 86 P12 77 P7 129 P2 145 P2 138 P2 132 P2 157 P2 147 P2 86 P2 143 P2 121 P2 141 P2 148 P2 147 P2 140 P2 143 P2
.136 P2 146 P2 134 P2 123 102 139 P2 144 P2.
142 P2 146 P2 154 P2 135 P2.
144 P2 93 P2 146 P2 148 P2 122 P2 138 P2 80 P2 140 P2 145 P2 145 P2 154 P2 150 P2 IND TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD VOL VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW 8
24 15 18 8
16 8
5 10 9
10 5
7 12 9
5 5
7 5
6 8
6 6
8 4
8 5
14 9
6 23 5
10 22 7
10 16 6
30 23 8
16 13 4
5 4
4 10 6
11 5
7 18 12 12 20 18 6
12 7
7 13 7
5 13 5
11 5
6 9
6 6
6 5
LOCATION 012
-0.39 012
-0.31 012
-0.34 012
-0.37 012
-0.39 010
-0.36 010
-0.34 012
-0.39 012
+0.28 012
-0.39 012.
+0..23 010
-0.36 010
-0.39 010
-0.41 014
-0.49 014
+0.23 007
+0.10 008
+0.10 007
-0.65 008
+0.16 006
+0.16 007
-0.60 010
-0.03 011
-0.75 008
-0.62 "008
+0.18 009
-0.57 009
-0.44 009
-0.41 013
-0.59 011
-0.41 009
-0.41 009
-0.41 010
+0.47 010
-0.29 012
-0.32 012
-0.37 010
-0.36 010
-0.36 012
-0.39 010
-0.36 612
-0.39 012
-0.39 010
-0.36 010
-0.36 014
-0.44 014
+0.29 012
+0.26 010
-0.39 012
+0.08 008
+0.16 007
+0.21 012
+0.18 012
-0.54 012
-0.36 010
+0.44 008
-0.31 012
-0.32 013
-0.34 012
+0.37
.012
-0.31 012
-0.37 012
-0.34 013
-0.42 010
-0.36 012
-0.36 010
-0.34 011
-0.41 012
+0.23 012
-0.16 010
-0.39 012
+0.23 007
-0.68 007
+0.13 008
+0.10 009
-0.54 009
-0.52 011
+0.13 011
+0.21 012
+0.23 EXT EXT LIE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE" LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 009 009 LTE UTE LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 010 010 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE" LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE -
LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR' WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR
- WAR, WAR WAR WAR UTIL 2
CAL 132 12 12 96 96 96 94 94 5
94 96 4
96 94 94 94 94 94 114 5
114 5
152 140 140 140 140 140 3
140 140 140 3
132 134 134 3
132 133 134 3
132 14 14 13 94 96 94 6
94 96 95 93 94 94 94 94 96 96 114 132 134 4
134 132
.0.
134 14 14 14 8
.14 12
.11 96 96 94 0
94 96 94 94 3
.94 94 94 7
509 152 140 132 4
553 134 3
132 5
.134
- LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB-510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB.
510XB 510XB 510XB 510XB 510XB 51OUL 510XB 510XB 510XB 51OUL 5i0XB 510XB 510XB
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:11:44 Component: S/G B Page 34 of 46 Service Induced Degradation QUERY: u2sga.qry ROW 98 98 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 99 100 100 100 100 100 100 100
-100 100 100 100 100 100 100 100 100 101 101 101 101 101 101 101
- 101, 101 101 101 101 101 101 ioo 102 102 102 102 102 102 COL 126 127 1
4 5
6 7
9 10 11 17 18 94 99 115 117 119 120 125 126 2
4 5
6 8
9 14 28 75 85 98 110 118 119 122 123 1
3 4
5 7.
8 9
10 85 98 108 115 116 117 124 2
3 4
5 6
9 10 VOLTS 0.07 0.14 0.13 0.09 0.12 0.12 0.46 1.87 0.07 0.52 0.11 2.02 0.11 0.10 0.20 0.11 0.09 0.15 0.09 0.10 0.07 0.13 0:12 0.13 0.13 0.07 0.09 0.12 0.06 0.09 0.13 0.17 2.95 0.64 0.13 0.07 0.06 0.09 0.19 0.07 0.07 0.11 0.06 0.04 0.12 0.10.
0.03 0.07 0.16 0.18 0.15-0.07 0.07 0.08 0.17 0.25 0.25 0.06
.0.11 0.08.
0.09 0.11 0.10
.0.09 0.04 0.09
.0.14 0.06 0.15 0.26 0.07 0.07 0.07 0.11 1.41 0.33 0.09 0.11 0.11 0.08 DEG CHN IND %TW LOCATION EXT EXT UTIL 1
148 P2 TWD 6 150 P2 TWD 11 135 P2 TWD 11 125 P2 TWD 8 142 P2 TWD 10 146 P2 TWD 10 138 P2 TWD 27 86 P14 VOL 126 P2 TWD 6 139 P2 TWD 29 147 P2 TWD 9 86 P14 VOL 151'P2 TWD 9 147 P2 TWD 8 142 P2 TWD 15 143 P2 TWD.9 139 P2 TWD 8 129 P2 TWD 11 123 P2 TWO 8 152 P2 TWD 8 153 P2 TWD 6 149 P2 TWD 11 147 P2 TWD 10 144 P2 TWD 10 143 P2 TWD 10 149 P2 TWD 6 150 P2 TWD 8 145 P2 TWD 8 140 P2 TWD 5 140 P2 TWD 7 149 P2 TWD 10 140 P2 TWD 13 79 P16 VOL 130 P2 TWD 33 147 P2 TWD 10 148 P2 TWD 5 146 P2 TWD 5 145 P2 TWD 7 150 P2 TWD 14 143 P2 TWD 6 140 P2 TWD 6 92 P2 TWD 9 137 P2 TWD 5 145 P2 TWD'4 106 P2 TWD T0 118 P2 TWD 9 151 P2 TWD 3 126 P2 TWD 6.
141 P2 TWD 13 149 P2 TWD 13 145 P2 TWD 12 155 P2 TWD 6 142 P2 TWD 6 130 P2 TWD 7 138 P2 TWD 14 133 P2 TWD 17 141 P2 TWD 17 141 P2 TWD 5 121 P2-TWD 9 151 P2 TWD 7 145 P2 TWD 8 145 P2 TWD 9 138 P2 TWD 8 90 P2 TWD 8 156 P2 TWD 4 152 P2 TWD 8 149 P2 TWD 12 152 P2 TWD 5 147 P2 TWD 12 143 P2 TWD 19 148 P2 TWD 6 131 P2 TWD 6 128 P2 TWD 6 141 P2 TWD 9 80 P15 VOL 135 P2 TWD 21 154 P2 TWD.7 150 P2 TWD 9 141 P2 TWD 8 142 P2 TWD 6 Ol Oili Oili 002 010 012 012 012 012 012 013 012 012 Oili Oili 012 012 014 009 007 012 009 013 012 Ol 007 007 012 010 012 013 012 012 012 013 013 012 010 012 014 014 014 014 008 008 Ol 008 009 009 012 009 Ol 012 012 012 012 012 010 010 012 012 010 Oili 009 007 Ol 012 012 012 Ol 012 010 010 013 012 012 012 013 012 010
-0.31
+0.37
-0.29
-0.23
-0.29
+0.37
-0.34
-0.34
+0.33
-0.37
-0.42
-0.37
+0.28
-0.41
-0.39
+0. 21
-0.57
-0.60
-0.57
+0.18
-0.47
- 0.41
-0.57
-0.36
+0.36
+0.10
-0.31
+0.37
-0.34
-0.31
-0.39
-0.36
-0.41
-0.41
+0.28
-0.49
+0.23
-0. 36
-0.45
+0.18
-0.57
-0.72
+0.00
+0.13
-0.60
-0.68
+0.16
-0.52
-0.44
-0.42
-0.39
+0.26
-0.34
-0.31
-0.26
-0.31
-0.34
-0.34
-0.36
-- 0.41
+0.23
-0.39
+0.29
-0:57
+0.18
+0.16
-0.47
-0.44
-0.41
+0.39
-0.32
-0.33
-0.34
-0.39
-0.36
-0.36
-0.39
+0.32
+0.23
-0.39 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE.
LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE.UTE LTE UTE LTE. UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE
.LTE UTE LTE UTE LTE UTE WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR' WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL 116 116 116 4
.116 14 14 96 95 5
94 96 96 95 5
94 3
94 96 94 94 96 140 132 0
134 134 134 132 114 116 4
116 12 94 94 96 5
94 93 94 94 5
94 4
94 96 96:
94 6
94 94 3
94 140 5
140 8
140 140 3
- 553, 132 132 4
132
.0 134
.4 132 0
134 14 94 96 94 94 3
94 96 9
94 0
96 140 132 132 134 2
132
.134 116 96 94 96 96 93 94 0
96 3
96 94 96
- LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET
-INLET INLET INLET INLET INLET INLET INLET INLET INLET
-INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XP 510XB 510kB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:45 Component:
S/G B Page 35 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL 102 22 102 103 102 108 102 111 102 112 102 114 102 115 103 1
103 3
103 5
103 6
103 7
103 8
103 10 103" 11 103 14 103 23 103 64 103 98.
103 111 103 113 103 114 103 115 103 116 103 117 103 118 103 123 104 3
104 4
104 6
104 7
VOLTS 0.09 0.08 0.10 0.06 0.06 0.07 0.08 0.09 0.11 0.15 0.11 0.14 0.22 0.31 1.05 0.16 0.11 0.15 0.14 0.08 0.18 0.08 0.07 0.09 0.07 0.09 0.06 0.06 0.06 0.09 0.08 0.06 0.09 0.06 0:07 0.27 0.09 0.21 0.15 1.97 0.08 0.25 0.34 0.11 0.09 0.24 0.09 0.05 0.14 0.10 0.07 0.19 1.42 0.33 0.15 0.18 0.12 0.i5 0.18 0.07 0.07 0.10 0.08 0.06 0.10 0.12 0.12 0.08 0.08 2.05 0.31 0.12 0.08 0.07 0.07 0.07 0.06 0.08 0.07 0.08 DEG CHN 153 P2 131 P2 83 P2 133 P2 156 P2 122 P2 147 P2 149 P2 133 P2 149 P2
.141 P2 139 P2 138 P2 139 P2 86 P13 140 P2 131 P2 138 P2 144 P2 157 P2 148 P2 149 P2 153 P2 101 P2 149 P2 142 P2 149 P2 151 P2 152 P2 141 P2 138 P2 139 P2 148 P2 141 P2 148 P2 138 P2 37 P2 142 P2 145 P2 84 P18 142 P2 140 P2 140 P2 141 P2 153 P2 141 P2 135 P2 155 P2 146 P2 143 P2 152 P2 141 P2 84 P18 135 P2 137 P2 144 P2 147 P2 150 P2 138 P2 141 P2 148 P2 128 P2 137 P2 145 P2 145 P2 152 P2 148 P2 129 P2 134 P2 96 6
136 P2 149 P2 136 P2 85 P2 139 P2 134 P2 150 P2 143 P2 132 P2 145 P2 IND %TW LOCATION EXT EXT UTIL 1
TWD 7 TWD 7 TWD 9 TWD 5 TWD 6 TWD 6 TWD 7 TWD 7 TWD 10 TWD 12 TWD 9 TWD 11 TWD 16 TWD 20 VOL TWD 12 TWD 8 TWD 11 TWD 11 TWD 7 TWD 14 TWD 7 TWD 6 TWD 8 TWD 7 TWD 8 TWD 6 TWD 5 TWD 5 TWD 9 TWD 7 TWD 5 TWD 7 TWD 5 TWD 6 TWD 18 TWD 7 TWD 15 TWD 12 VOL TWD 6 TWD 17 TWD 22 TWD 9 TWD 7 TWD 1.7 TWD 8 TWD 5 TWD 12 TWD 9 TWD 6' TWD 14 VOL TWD 21 TWD 11 TWD 14 TWD 10 TWD 11 TWD 13 TWD 6.
TWD 6 TWD 8 TWD 7 TWD 5 TWD 9 TWD 10 TWD 9 TWD 7 TWD 6 VOL TWD 20 TWD 9 TWD 6 TWD 5 TWD 6 TWD 6 TWD 5 TWD 8 TWD 6 TWD 7 012 010 012 011 006 012 012 012 012 012 013 012 012 012 012 012 010 Ol 012 012 014 Ol 012 007 007 012 012 012 012 014 012 010 010 013 011 012 010 012 012 014 010 012 014 012 014 014 012 012 010 012 010 012 012 012 014 012 012 014 014 012 014 014 009 009 012 013 010 013 010 012 012 012 010 012 013
- 011 Oil 012 006 013
-0.47
+0.10
-0.57
+0.18
+0.36
-0.52
-0.44
-0.44
-0.31
-0.32
-0.36
+0.31
-0.33
-0.37
-0.37
+0.23
-0.36
+0.26
+0.21
+0.21
-0.50
-0.46
+0.03
-0.63
+0.21
+0.21
-0.47
-0.44
+0.18
-0.52
-0.42
+0.47
-0.42
-0.57
+0.39
-0.31
+0.68
-0.34
-0 37
-0.41
-0.33
-0.39
-0.41
+0.28
-0.45
+0.29
-0.55
-0.42.
-0.39
-0.36
-0.39
-0.34
-0.33
-0.33
-0.41
-0.42
-0.49
+0.26
-0.49
-0.68
.+0.03
-0.52
-0.49
-0.52
-0.57
-0. 41
-0.31
-0.34
-0.42
-0.42
-0.50
+0.16
+0.05
-0.76
+0.16
+0.29
-0.31
-0.28
-0.37
- LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE 'UTE LTE UTE LTE UTE
- LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE
- LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 014 014 LTE UTE LTE UTE LTE UTE LTE U TE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE 'UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE
ýLTE UTE LTE UTE WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR
- WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR.
WAR WAR WAR WAR WAR UTIL 2
CAL # LEG 96 INLET 5
505 INLET 3
136 INLET 138 INLET 136 INLET 4
138 INLET 4
138 INLET 132 INLET 14 INLET 96 INLET 96 INLET 4
96 INLET 94 INLET 96 INLET 95 INLET 94 INLET 4
94 INLET 94 INLET 94 INLET 96 INLET 96 INLET 4
94 INLET 4
507 INLET 140 INLET 136 INLET 136 INLET 0
136 INLET 3
138 INLET 3
138 INLET 6
136 INLET 138 INLET 3
136 INLET 138 INLET.
2 138 INLET 114 INLET 94 INLET 96 INLET 96 INLET 96 INLET 93 INLET 94 INLET 94
-INLET 94 INLET 5
94 INLET 96 INLET 96 INLET 96-,
INLET 4
136 INLET 136 INLET 136 INLET 138 INLET 96 INLET 93 INLET 94
- INLET 94 INLET 5
94 INLET 96 INLET 94 INLET 94 INLET 94 INLET 88 INLET 88 INLET 4
553 INLET 0
553.
INLET 136 INLET
-138 INLET 138 INLET 0
88 INLET 0
88 INLET 87 INLET 4
88 INLET 88 INLET 0
88 INLET 88 INLET 140 INLET 138 INLET 0
138 INLET 136 INLET 3
138 INLET
. 88 INLET PROBE 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB.
510XB 510XB 510XB 510XB" 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 51OXE 510XB 510XB 51OUL 51OUL 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 104 104 104 104 104 105 105 105 105 105 105 105 105 105 105 105 105 106 106 106 106 106 106 106 106 106 106 106 107 8
20 115 117 118 3
4 6
7 10 12 25 95 97 109 112 116 1
4 9
12 19 22 92.
105 113 118 121 j
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:11:45 Component: S/G B Page 36 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS DEG CHN IND %TW LOCATION EXT EXT UTIL 1
UTIL 2
CAL # LEG PROBE 107 5
0.17 107 6
0.17 0.06 107 8
0.27 0.08 107 11 0.10 0.10 0.18 107 23 0.12 107 96 0.07 107 114 0.07 107 120 0.05 108 3
0.25 108 4
0.07 108 7
0.16 108 12 0.14 108 26 0.06 108 81 0.08 108 "97 0.10
.0.11 108 104 0.08 108 109- 0.12 108 119 0.09 109 4
0.22 109 5
0.16 109 6
0.08 0.21 0.39 0.15 2.47 109 7
0.10 0.12 0.10 109 12 0.08 0.14 109 18 0.07 109 25 0.07 109 96 0.14 109 105 0.06 109 107 0.13 110 3
1.32 0.33 110 5
0.22 0.15 110 7
0.20 110 9
2.36 0.48 110 11 0.10 110 18 0.15 0.08 110 108 0.24 0.10 110 111 0.05 110 117 0.08 111 5
0.10 111 7
0.14 0.09 111 8
0.13 111 13 0.10 111 17 0.06 111 106 0.06 111 110 0.16 111 116 0.07 0.04 112 4
0.10 0.11 112 6
0.09 112 10 0.09 112 11 0.08 0.07 112 18 0.11 112
-57 0.04 112 72 0.03 112 97 0.12 112 105 0.15 112 108 0.05 0.05 112 110 0.07 136 P2 TWD 13 012 140 P2 TWD 12 012 153 P2 TWD 5 012 141 P2 TWD 18 012 110 P2 TWD 7 013 148 P2 TWD 8 011 140 P2 TWD 8 012 140 P2 TWD 13 014 130 P2 TWD 9 012 145 P2 TWD 7 01i 154 P2 TWD 6 010 150 P2 TWDO5 011 140 P2 TWD 17 012 147 P2 TWD 6 012 146 P2 TWD 12 012 138 P2 TWD 11, 012 143 P2 TWD 5 010 118 P2 TWD 7 006 144 P2 TWD 9
- 009 112 P2 TWD 10 012
-142 P2 TWD 8 011 148 P2 TWD 9 011 141 P2 TWD 7 011.
134 P2 TWD 16 012 142 P2 TWD 12 013 144 P2 TWD 6 012 142 P2 TWD 15 013 139 P2 TWD 24' 014 144 P2' TWD 11 013 99 138 VOL 014 142 P2 TWD 8 014 146 P2 TWD 9 014 153 P2 TWD 8 012 147.P2 TWD 6 014 145 P2 TWD 11 014 140 P2 TWD 6 012 125 P2 TWD 6 010 120 P2 TWD 12 012 114 P2 TWD 5 012 141 P2 TWD 10 012 94 6
VOL 012 138 P2 TWD 21 012 138 P2 TWD 15 0i2
,139 P2 TWD 11 014 149 P2 TWD 14 012 114 142 VOL 012 140 P2 TWD 27 012 154 P2 TWD 8 012 127 P2 TWD i 013 146 P2 TWD 6 013 134 P2 TWD 19 013 155 P2 TWD 9 011 147 P2 TWD 4 010 146 P2 TWD 6 006 149 P2 TWD 8 013 148 P2 TWD 10 012 148 P2 TWD 7 014 148 P2 TWD 10 011 152 P2 TWD 8 014 144 P2 TWD 5 011 162 P2 TWD 5 911 147 P2 TWD 12 010 142 P2 TWD 6 007 157 P2 TWD 4 007 144 P2 TWD 8
'012 147 P2 TWD 9 013 149 P2 TWD 7.
013 127 P2 TWD 8 012 159 P2 TWD 6 012 143 P2. TWD 6 014 147 P2 TWD 9 014 103 P2 TWD 4 008 119 P2 TWD 3 008 128 P2. TWD-li 012 151 P2 TWDO13 011 155 P2 TWD 5 011 119 P2 TWD 5. 014 140 P2 TWD 7 010
-0.37
-0. 39
+0.26
-0.45
-0.42
+0.29
-0.47
-0.50
-0.55
+0.05
-0.39 to.i0
-0.34
+0.34
-0.39
-0.49
+0.08
-0.54
-0.52
-0.62
-0.50
-0.41
+0.36
-0.31
-0.42
-0.34
-0.44
-0.42
+0.31
-0.44
-0.39
+0.29
-0.42
-0.52
+0.21
-0.03
+0.03
-0.60
-0.50
-0.50
-0.34
-0.37
-0.39
-0.37
-0.37
+0.13
+0.21
-0.45
-0.62
+0.16
-0.55
+0.23
-0.39
+0.41
+0.31
+0.26
-0.42
-0.36
-0.53
+0.21
-0.49
-0.42
-0.31
+0.05
-0.31
-0.34
-0.36
+0.26
-0.45
-0.45
-0.62
+0.15
+0.21
-0.57
+0.23
+0.29
+0.24
-0.41
-0.39
- 0.36 LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTEUTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE -UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 014 014 WAR LTE UTE WAR
.LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE-UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR
-LTE UTE
-WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE
'WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR
- LTE UTE WAR LTE UTE-WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 88 88 0
88 88 88 88 88 88 6
507 136 3
138 0
138 88 4
152 88 152 88 140 136 136 4
136 3
138 0
154 86 88 86 86 86 5
86 85 88 88 0
88 86 86 4
86 86 136 5
138 138 87 88 88 88 88 87 88 88 86 4
86 136 0
136 3
138 138 0
88 88 0
88 86 88 0
88.
2 138 138 4
136 3
136 86 86 5
86 86 88 88 86 114 140 6 -
136
.136 2
136 0
136 3
136 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB "510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 112 I11 0.14 148 P2 TWD 12 112 114 0.06 152 P2 TWD 6 010 012 136 INLET 510XB 0
136 INLET 510XB
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:11:45 Component: S/G B Page 37 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 112 116 0.06 112 117 0.05 113 3
0.17 113 5
0.13 113 6
0.08 113 10 1.84 0.35 0.17 113 16 0.17 113 101 0.07 113 104 0.10 0.06 113 106 0.07 113 108 0.12 113 116 0.08
-0.03 114 1
0.14 114 2
0.04 114 4
0.11 114 5
0.09 114 61 0.08 114 99
- 0. 07 114 106 0.07 114 107 0.14 114 109 0.07 114 115 0.05 115 4
0.13 115 6
0.16 0.18 0.09 115 7
0.20 0.08 115 8
0.12 0.06 0.10 0.06 0.07 0.06 115 19 0.08 115 86 0.10 115 98 0.07 115 104 0.06 0.07 115 106 0.05 115 107 0.06 115 114
- 0. 09 116 1
1.20 0.15 0.36 0.12 116 2
0.10 116 3
0.08 0.12 116 7
0.08 0.07 116 66 0.08 116 89 0.07 116 93 0.14 116 94 0.13 0.19 0.15 116 97
-0.14 116 103 0.10 116 105 0.09 116-106 0.18 116 113 0.10 117 1
0.12 117 4
0.24 0.13 117 5
0.16 0.09 117. 9 0.06 117 10 0.20 117 26 0.11 0.12 117 46 0.03 117 72 0.07 117 81 0.06 117 86 0.09 117 87 0.07 DEG CHN 152 P2 148 P2 149 P2 147 P2 151 P2 95 22 139 P2 151 P2 148 P2 157 P2 156 P2 138 P2 100 P2 152 P2 141 P2 154 P2 145 P2 149 P2 133 P2 152 P2 140 P2 157 P2 149 P2 146 P2 152 P2 111 P2 141 P2 147 P2 142 P2 131 P2 147 P2 139 P2 136 P2 155 P2 148 P2 147 P2 141 P2 149 P2 146 P2 142 P2 153 P2 132 P2 151 P2 159 P2 148 P2 150 P2 93 142 122 P2 131 P2 133 P2 146 P2 155 P2 142 P2 149 P2 139 P2 153 P2 156 P2 132 P2 132 P2 124 P2 142 P2 136 P2 142 P2 133 P2 142 P2 135 P2 139 P2 138 P2 147 P2 151 P2 148 P2 150 P2 137 P2 137 P2 139 P2 122 P2 127 P2 141 P2 159 P2 152 P2 IND TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW LOCATION 6
006 5
007 13 012 10 012 6
012 012 22 012 12 014 13 012 6
010 9
012 5
012 6
012
- 11. 010 6
011 3
001 10 012 4
013 9
013 7
013 5
007 7
009 6
009 11 010 6
010 4
011 10 012-12 012 13 012 7
013 15 012 7
012 9
011 5
014 8
014 5
012 6
012 5
012 6
012 9
014 6
012 6
009 7
012 5
010 7
010 7
011 015 11 012 22 015 9
010 8
012 6
012 9
012 7
012 6
, 012 6
010 5
007 13 009 11 012 15 013 12 014 13 009 10 009 8
010 15 010 10 011 9
013 16 012 10 013 12 012.
7 012 5
013 14 012-9 014 10 014
-3 008 7
006 5
011 6
011 6
011
+0.41
-0.28
-0.29
-0.31
-0.37
-0.50
-0.45
-0.45
-0.55
+0.57
-0.47
+0.23
-0.63
-0.41
-0.28
+0.18
+0.34
-0.34
-0.36
+0.39
+0.08
-0.44
-0.44
-0.42
-0.39
-0.18
+0.31
-0.39
+0.26
-0.39
-0.34
+0.29
-0.37
-0.42
+0.32
-0.16
+0.21
-0.39
+0.10
+0.00
-0.55
-0.42
-0.47
-0.44
-0.44
+0.39
-0.39
-0.29
-0.37
-0.23
-0.28
-0.32
+0.31
-0.42
+0.26
+0.05
-0.48
-0.47
-0.57
-0.65
-0.63
-0.44
-0.41
-0.42
-0.41
-0.36
-0.31
-0.34
-0.39
-0.34"
+0.31
-0.47
+0.21
-0.73
-0.03
+0.13
-0.57
+0.10
+0.10
+0.03 EXT LTE LTE LTE LTE LTE 012 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE 015 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE EXT UTE UTE UTE UTE UTE 012 UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE 015 UTE UTE UTE UTE UTE UTE uTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTE UTIL 1
UTIL WAR WAR 3
WAR WAR WAR 0
WAR WAR WAR WAR WAR 4
WAR WAR 3
WAR 2
WAR WAR WAR WAR
- 5 WAR WAR WAR 0
WAR 3
WAR WAR WAR WAR WAR WAR WAR WAR WAR 0
WAR WAR 4
WAR WAR WAR WAR WAR WAR 0
WAR 4
WAR WAR 3
WAR WAR WAR 2
WAR WAR WAR-WAR WAR WAR 0
WAR WAR WAR 5
WAR 0
WAR 0
WAR 3
WAR 3
WAR 4
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 4-WAR WAR 4
WAR 2
CAL 136 136 86 86 88 87 88 88 88 136 140 140 140 140 154 154 88 86 "86 88 535 142 140 152 152 154 88 88 88 88 86 86 88 88 88 88 88 88 86 140 140 140 140 140 142 154 87 88 88 88 86 88 88 88 88 535 535 142 140 140 140 142 142 152 140 142 88 88 88 86 86 86 88 106 106 i06 533 140 535 140
- LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510UL 510XB 510XB
- 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB "510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 51OUL 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:46 Component:
S/G B Page 38 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.10 0:09 117 89 0.08 117 99 0.18 117 100 0.08 117 102 0.10 117 103 0.15 117 104 0.98 0.43 0.08 118 5
0.12 0.05 118 6
0.08 118 9
0.10 118 14 0.07 i18 42 0.09 118 78 0.10 118 100 0.06 118 101 0.09 119 2
0.17 0.12 0.14 119 4
0.18 119 5
0.17 119 8
0.21 119 9
0.12 119 11 0.10 0.11 119 17 0.09 119 28 0.05 119 92 0.09 119 96 0.07 119 99 0.07 119 100 0.08 120 1
0.20 120 4
0.15 120 7
0.15 0.09 120 10 0.21 120 11 0.10 120 20 0.06 0.06 120 28 0.07 120 76 0.08 120 83 0.19 0.12
-0.25 0.09 120 86 0.08 121 8
0.05 121
- 9 0.11 121 10 0.14 0.13 121 13 0'13 121 78 0.14 121 99 0.23 0.12 121 100 0.13 122 8
0.15 122 9
0.10 0.06 122 12 0.08 0.20 0.09 122 25 0.08
.122 34 0.08 122 90 0.10 122 96 0.07 122 97 0.26 0.09 122 98 0.07 o
0.07 123 1
0.19 123 9
.. 2.16 0.37 0.27 0.21 123 11 0.10 123 24 0.07 123 75 0.09 DEG 137 132 152 141 154 134 145 69 136 153 140 155 144 149 137 126 119 121 131 126 139 144 144 120 135 151 154 148 148 157 155 149 149 150 137 137 146 142 139 152 106 142 144 86 122 121 128 145 i1 159 139.
140 138 143 162 145.
151 130 139 151 156 155*
145 141 135 153 134 144 145 137 128 146 140 102 139 145 138 151 151 94 CHN IND P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2
-TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD 46 VOL P2 TWO P2 TWD P2 TWD P2 TWD P2 TWD P2 TWD
%TW 9
8 7
14 8
8 30 8
9 4
7 8
6 7
9 5
8 12 9
11 13 13 15 9
8 9
7 4
7 6.
6 7
15 11 11 8
15 8
5 5
6 7
15 10 19 8
7 4
9 11 10 10 9
17.
10 10 11 8
5 6
14 7
7 7
8 6
18 7
6.
7 14 23 18 15 8
6 8
LOCATION 009
-0.52 011
-0.54 011
-0.52 009
-0.42 012
-0.47 010
-0.44 010
-0.44 010
-0.41 010
-0'.41 014
+0.29 012
-0.39 014
+0.34 013
-0.44 012
-0. 44 014
+0.16 010
+0.05 012
-0.68 011
+0.29
.010
-0.44 010
-0.28 012
-0.31 013
-0.34 012
-0.31 010
+0.08 012
+0.31 013
-0.50 014
-0.47 014
+0.24 012
+0.13 011
+0.08 013
+0.13 009
+0..60 009
-0.42 012
-0.42 012
+0.34 012
-0.34 012
-0.39 012
+0.26 012
+0.23 012
-0.47 010
+0.18 014
+0.10 010
+0.08 012
-0.62 012
-0.60 013
-0.68 014
-0.68 014
+0.03 012
-0.60 012
-0.45 014
+0.29 014
-0.47 014
+0.24 014
+0.21 011
+0.21 010
-0.41 012
-0.39 010
-0.39 012
-0.39 012
-0.39 012
+0.21 012
-0.44 014
-0.46 014
+0.26 012
-0.60 010
+0.13 012
-0.55 009
-0.39 013
-0.50 013
+0.26 010
-0.39 013
-0.47 013
-0.31 012
-0.44 012
-0.42 014
-0.45 014
+0.18 012
-0.44 014
+0.00 012
-0.65 EXT LTE LTE LTE LTE LTE LTE LTE 010 LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE LTE
-012 LTE LTE LTE LTE LTE LTE EXT UTIL 1
UTIL 2
UTE WAR 3
UTE WAR 3
UTE WAR UTE WAR UTE WAR 3
UTE WAR UTE WAR 010 WAR UTE-WAR UTE WAR 0
UTE WAR UTE WAR UTE WAR 4
UTE WAR UTE WAR 4
UTE WAR
.3 UTE WAR UTE WAR 3
UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 5
UTE WAR UTE MWAR UTE WAR UTE WAR UTE WAR UTE WAR
.0 UTE WAR 3.
UTE WAR UTE WAR UTE WAR' UTE WAR UTE WAR UTE" WAR 3
UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 0
UTE WAR UTE WAR UTE WAR UTE WAR 5.
UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR 0
UTE WAR 4
UTE WAR 012
.WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR UTE WAR CAL # LEG 140 140 140 140 142 152 140 141 142 142 88 88 86 88 86 517 140 140 152 78 78 78 78 80 78 80 80 80 80 106 130 130 128 130 80 78 80 8078 80 78 78 106 140 140 140 140 140 140 80 78 80 80 78 531 126 126 124 78 80 80.
78 78 78 108 106 126 126 124 124 126 126 80 79 80 80 80 80 106 140 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510UL 510XB 510XB 510XB
-510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51oxB 510XB 510XB 510XB 510XB 510XB 510XB 516XB 510XB 510XB 510XB 510XB 51OXB 510UL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB.
510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:47 Component: S/G B Page 39 of 46 Service QUERY:
u2sga.qry ROW COL VOLTS DEG 123.
90 0.07 143.
0.10 121 0.09 139 123 94 0.14 134 123
- 96.
0.19 142 123 97 2.03 106 0.58 130 124 7
0.13 158 124 8
0.11 127 0.06 150 0.09 150 0.08 147 124 11 0.11 139 124 17 0.16 144 0.07 131 124 18 0.06.
157 124 82 0.10 130 124 84 0.08 138 124 95 0.15 137 125 7
0.17 138 0.16 147 125 8
0.15 133 125 9
'1.96 109 0.09 156 0.18 135 0.32
.138 125 10 0.08 149 125 14 0*07 146 125 57 0.07 153 125 90 0.13 138 125 91 0.13 139 125 92 0.09 148 0.09 152 125 93 0.14 142 126 8
2.36 96 0.36 135 0.11 145 0.12 152 126 9
1.19 112 0.34 144 0.25 140 126 10 0.11 144 0.13 146 0.13 145 126 11 0.15 137 0.16 136 0.11 156 0.07 150 126 17 0.26 143 126 18 0.07 131 126 20 0.07 139 126 24 0.12 150 126 61 0.07 147 126 72 0.09 150 126 76 0.12 139 126 77 0.06 139 126 82 0.12 129 0.07 156 126 86 0.10 123 0.15 146 126 90 0.18 139 126 91 0.03 152 0.07 139 126 93 0.12 141 126 94 0.08 120 127 5
0.09 126 127 6
0.08 151 127 7
0.07 126 0.13 122 127 12 0.09 155 127 15 0.20 136 127 71 0.07 122 0.07 85 127 90 0.10 153 128 6
0.19 143 128 7
0.06 154 128 8
0.27 136 0.12 152 0.12 145 0.18 145 Induced Degradation CHN IND %TW P2 TWD 6 P2' TWD 9 P2 TWD 8 P2 TWD 12 P2 TWD 15 46 VOL P2 TWD 30 P2 TWD 10 P2 TWD 8 P2 TWD 5 P2 TWD 7 P2 TWD 6 P2 TWD 9 P2 TWD 12 P2 TWD 6 P2 TWD 5 P2 TWD 9 P2 TWD 7 P2 TWD 11 P2 TWD 13 P2 TWD 12 P2 TWD 11 38 VOL P2 TWD 7 P2 TWD 13 P2 TWD 21 P2 TWD 6 P2 TWD 6 P2 TWD 6 P2 TWD 11 P2 TWD 10 P2 TWD 8 P2 TWD 8 P2 TWD 11 114 VOL P2 TWD 22 P2 TWD 8 P2 TWD 9 122 VOL P2 TWD 22 P2 TWD 17 P2 TWD 9 P2 TWD 10 P2 TWD 10 P2 TWO 12 P2 TWD 12 P2 TWD 9 P2 TWD 6 P2 TWD 18 P2 TWD 6 P2 TWD 6 P2 -TWD 10 P2 TWD 6 P2-TWD 8 P2 TWD 10 P2 TWD 6 P2 TWD 10 P2 TWD 6 P2 TWD 8 P2 TWD 11 P2 TWD 13 P2 TWD 2 P2 TWD 6 P2 TWD 9 P2 TWD 6 P2 TWD 7 P2 TWD 7 P2 TWD 5 P2 TWD 10 P2 TWD 8 P2 TWD 14 P2 TWD 6 P2 TWD 6 P2 TWD 9 P2 TWD 14 P2 TWD 5 P2 TWD 18 P2 TWD 9 P2 TWD 9 P2 TWD 13 LOCATION 012
+0.29
.014
-0.57 014
+0.18 012
-0.47 012
-0.39 010
-0.44 010
-0.39 014
<-0.39 011
-0.18 011 t0.29 012
- -0.37 014
+0.21 014
+0.16 014
-0.57 014
+0.03 014
+0.03 012
-0.55 012
-0.52 010
-0.39 012
-0.39 013
-0.44 014
-0.42 012
-0.42 014
+0.18 010
+0.65 012
-0.42 012
+0.26 012
+0.16 010
+0.08 012
-0.44 011
-0.39 009
-0.41 012
-0.39 010
-0.39 012*
-0.36 012
-0.34 011
+0.31 014
+0.21 012
-,+0.18 012
+0.24 014
-0.42 012
+0.21 014
-0.44 014
+0.18 011
-0.31 012
+0.18 014
-0.42 014
+0.18 014
-0.55 012
+0.13 011
+0.18 010
+0.16 011
+0.03 013
+0.03 012
-0.60 01i
-0.52 013
-0.58 013
+0.16 013
+0.05, 014
-0.55 009
-0.39 012.
+0.26 009
-0.42 010
-0.36 010
-0.34 012
-0.31 012
-0.34 012
-0.34 012
+0.26 014
+0.16 014
-0.49 012
-0.57 012
+0.68 010
-0.36 012
+0-26 014
-0.39 012.
-0.31.
014
-0.42 014
+0.18 013
-0.44 EXT EXT LTE UTE LTE UTE LTEUTE LTE UTE LTE UTE 010 010 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE.UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE.UTE LTE UTE LTE uTE.
LTE UTE LTE UTE LTE UTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR
.WAR WAR
-WAR WAR.
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL #.LEG 126 126 126 0
126 126 123 124 80 5
78 3
78 5
78 4
78 0
80 78 5
78 0
108 144 4
140 124 80 80 78 79 80 80 80 4
78 78 0
529 0
126 5
124 126
- 126, 124 77 78 4
78 78 7-9 80 80 78 78 78 80 80 80 80.
106 4
108 4
108 108 0
529 144 8
146 5
144 146 146 124 124 124 124 3
.124 124 4
124 4
78
.0
.80 78 78 0
80 78 0
146 0
146 126 78
.80 78 78 5
78 5
78 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET
'INLET INLET INLET INLET INLET INLET INLET INLET INLET-INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 51OXB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB
.510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 5-10UL 510XB 510XB 510XB
ý510XBý 510XB 510XP 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB.
510XB 510XB 510XB 510XB 510XB 510XB 510XB
.510XB
.510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name:
ONS2 Repl 01/20/09 02:11:48 Component: S/G B Page 40 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 128 9
0.12 0.12 0.20 128 10 0.14 128 13 0.21 128 19 0.10 0.19 0.08 0.13 128 29 0.15 0.21 128 31 0.29 0.08 1.34 128 59 0.10 128 78 0.11 128 88 0.13 0.09 128 89 0.08 129 6
0.14 129 8
0.06 0.09 129 11 0.16 129 15 0.11 129 19 0.07 129 35 0.07 0.21 129 63 0.10 129 84 0.05 0.05 129 89 0.09 129 90 0.08 0.07 130 6
0.10 130 8
0.13 130 9
0.10 130 14 0.12 0.07 130 16 0.13 0.22 130 26 0.24 130 28 0.27 130 43 0.07 130 47 0.08 130 72 0.05 130 83 0.11 0.10
.130 84 0.26 130 89 0.06 130 92 0.08 131 4
0.06 131-5 0.14 131 7
0.08 131 8
0.12 0.09 131 11 0.18 131 12 0.10 0.09 131.
13 0.03 0.07 131 34 0.1:7 131 39 0.20 0.09 131.
43 0.05 131 44 0.05 131 47 0.11 131 50 0.08 131 53 0.09 0.11 0.04 131 66 0.08 131 70 0.08 131 79 0.15 0.12 131 80 0.12 131 85 0.09 132.
1 0.11 132 4
0.07 132 8
0.14 0.25 DEG CHN 128 P2 147 P2 137 P2 141 P2 1,45 P2 139 P2 137 P2 145 P2 136 P2 136 P2 137 P2.
136 P2 143 P2 81 P25 125 P2 137 P2 133 P2 141 P2 153 -P2 139 P2 150 P2 124 P2 139 P2 144 P2 129 P2 130 P2 142 P2 128 P2 132 P2 135 P2 149 P2 117 P2 132 P2, 136 P2 142 P2 150 P2 139 P2 135 P2 152 P2 137 P2 143 P2 140 P2 156 P2 108 P2 156 P2 155 P2 130 P2 136 P2 148 P2 143 P2 152 P2 140 P2 143 P2 140 P2 151 P2 144 P2 153 P2 134 P2 90 P2 144 P2 142 P2 135 P2 151 P2 145 P2 150 P2 137 P2 47 P2 139 P2 127 P2 163 P2 134 P2 122 P2 148-P2 150 P2 148 P2 116 P2 145 P2 129 P2 138 P2 136 P2 IND TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD
%TW 10 9
15 11 15 8
14 7
11 11 15 20 7
7 9
10 7
7 10 5
7 12 9
66 15 9
4 5
7 6
5 8
10 8
10 6
10 16 17 19 6
7 5
9 8
19 5
7 5
10 7
9 7
13 8
7 3
6 13 15 7
4 4
10 7
8 10 4
7 7
12 10 10 7
9 6
10 17 LOCATION 011 012-012 012 012 012 012 014 014 014 014 014 010 014 006 012 010 014 012 012 014 014 014 014.
012 014 014 012 009 009 Oili 010 012 012 014 012 012 0i2.
014 014 014 010 010 012 009.
011.
010 010 013 012 -.
012 012 012 012 014 012 012
.013 013.
010 014 014 010 011 012 012 014 014 013 012 011 014 014 012 010 Ofl 012 012 012
-0.21
-0.42
+0.24
-0.36
+0.21
-0.52
+0.16
-0.57
+0.08
-0.03
-0.36
-0.03
+0.16
-0.05
-0.44
-0.52
-0.36
+0.29
-0.39
+0.26
-0.42
+0.21
+0.18
-0.49
-0.52
-0.73
-0.05
-0.62
-0.39
-0.42
+0.34
-0.31
-0.37
-0.36
-0.36
-0.39
-0.39
+0.21
-0.47
+0.16
+0.00.
+0.21
+0.16
-0.60
+0.16
-0.42
+0.26
-0.39
-0.34
+0.34
-0.31
+0.29
-0.47
-0.39
- 0.26
-0.41
-0.42
+0.21
+0.70
-0.54
+0.16
-0.70
+0.03
+0.18
+0.13
-0.65
-0.62
-0.65
+0.05
+0.05
-0.55
-0.55
-0.50
+0.24
-0.39
-0.31
-0.37
+0.28
-0.39
+0.28 EXT EXT UTIL LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 014 014 WAR ITE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE.UTE. WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE'UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE.UTE WAR LTE UTE WAR LTE UTE WAR LTE.UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR-LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 1
UTIL 2
CAL #
80 80 80 7
78 80 106 106 106 106 106 6
106 106 5
106 105 4
531 5
146 124 124 126 78 78 78 78 106 4
106 106 106 4
529 122 IDOK 120 0
120 122 122
.4 78 78 80 5
106 4
106 106 106 106 106 108 5
144 144 122 122 120 122 120 80 78 78 80 80 78 108
- 3.
108 3
106 4
106 108 106 106 106 0
108 146 3
144 146 146 S146 4
144 0
144 120 120 122 126 80 78 78 "78 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET
.INLET TINLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XB SKoXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OUL 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51bXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
- 510XB, 510XB.
510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:49 Component: S/G B Page 41 of 46 Service QUERY: u2sga.qry Induced Degradation ROW 132 132 132 132 132 132 132 132 132 132 132 132 132 133 133 133 133 133 133 133 133 133 133 133 133 133 133 134 134 134 134 134 134 134 134 134 134 135 135 135 135 135 135 135 135 135 135 136 136 136 136 136 136 136 136 136 COL 15 18 36 43 47 52 54 69 71 72 80 81 82 2
3 6
7 10 12 14 18 21 26 31 39 68 69 2
8 10 13 21 43 52 66 77 85 5
6 7
14 43 44 56 67 74 75 1
9 10 11 12 14 32 39 42 VOLTS 0.13 0.04 0.26 0.07 0.07 0.14 0.16 0.07 0.07 0.11 0.17 0.14 0.14 0.07 0.07 0.07 0.07 0.09 0.10 0.19 0.18 0.09 0.20 0.16 0.20 0.08 0.09 0.16 0.07 0.10 0.11 0.08 0.06 0.21 0.15 0.15 0-.12 0.09 0.11 0.08 0.08 0.09 0.07 0.1i 0.05 0.06 0.07 0.10 0.08 0.09 0-.10 0.06
- 0.11 0.12 0.06 0.08 0.08 0.17 0.10 0.08 0.10 0.06 1.75 0.29 0.10 0.14 0.09 0.07 2.92 3.27 0.64 0.40 0.12
,0.14 0.21 0.06 0.11 0.18 0.06 0.06 DEG CHN IND %TW LOCATION 150 P2 TWD 11 014
-0.37 137 P2 TWD 4 014
+0.13 137 P2 TWD 18 014
-0.57 154 P2 TWD 6 014
+0.08 97 P2 TWD 6 012
-0.57 112 P2 TWD 11 012
-0.57 134 P2 TWD 13 012
-0.65 148 P2 TWD 6 012
+0.08 136 P2 TWD 7 011
-0.42 106 P2 TWD 9 012
-0.60 142 P2 TWD 14 012
-0.55 138 P2 TWD 11 012
-0.52 132 P2 TWD 11 012
-0.52 131 P2 TWD 6 009
-0.42 131 P2 TWD 6 010
-0.39 147 P2 TWD 6 010
-0.37 83 P2 TWD 6 010
-0.34 156 P2 TWD 7 012
+0.29 148 P2 TWD 8 012
-0.34 144 P2 TWD 14 012
+0.13 146 P2 TWD 13 012
+0.28 143 P2 TWD 8 014
-0.42 146 P2 TWD 15 012
+0.21 143 P2 TWD 13 014
-0.50 145 P2 TWD 15 014
+0.03 141 P2 TWD 6 013
-0.55 151 P2 TWD 7 012
-0.52 143 P2 TWD 12 014
+0.03 121 P2 TWD 6 014
-0.60 146 P2 TWD 8 012
-0.52 133 P2 TWD 9 014
-0.65 107 P2 TWD 7 015
-0.65 151 P2 TWD 5 015
+0.08 133 P2 TWD 16 014
-0.58 150 P2 TWD 12 014
+0.16 145 P2 TWD 12 014
+0.16 122 P2 TWD 9 011
-0.23 145 P2 TWD 7 012
+0.26 130 P2 TWD 9 012
+0.26 153 P2 TWD 7 010 40.63 145 P2 TWD 6 012
-0.45 127 P2 TWD 8
012
-0.60 134 P2 TWD 7 011
-0.42 127 P2 TWD 10 012
-0.52 145 P2 TWD 4
012
+0.29 149 P2 TWD 5 010
-0.34 136.P2 TWD 6
012
+0.29 119 P2 TWD 8 006
-0.26 145 P2 TWD 7 012
+0'.26 151 P2 TWD 8 012
+0.31 137 P2 TWD 8 014
-0.
3 6 156 P2(
TWD 5 014
+0.21 153 P2 TWD 9
012
+0.21 143 P2 TWD 10 014
+0.16 129 P2 TWD 6
015
-0.60 136 P2 TWD 7 012
+0.26 152 P2 TWD 7 014
+0;10 141 P2 TWD 14 012
-0.47 152 P2 TWD 9 012
-0.42 119 P2 TWD 7 010 r0.36 141 P2 TWDO9 012
-0.39 156 P2 TWD 5 012
+0.31 100 18 VOL 015
-0.39 137 P2 TWD 20 015
'-0.37 149 P2 TWD 9 014
'-0.39 148 P2.
TWD 11 014
+0.21 141 P2 TWD 7 012
-0.39 152 P2 TWD 6 012
+0.26 98 150 VOL 014
-0.50 95 102 VOL 013
-0.47 134 P2 TWD 34 013
- -0.47 142 P2 TWD 26 014
-0.42 149 P2 TWD 10 014
+0.18 145 P2 TWD 11 013
+0.24 141 P2 TWD 15 012
+0;26 150 P2 TWD 5 014
+0.18 140 P2 TWD 9 012
-0.55 142 P2 TWD 13 0i2
+0.16 156 P2 TWD 5 012
+0.13 153 P2 TWD 5 012
+0.16 EXT EXT UTIL 1
UTIL 2
CAL # LEG LTE UTE WAR
.= 3 108 LTE UTE WAR 4
108 LTE UTE WAR 106 LTE UTE WAR 106 LTE UTE WAR 5
106 LTE UTE WAR 108 LTE UTE WAR 146 LTE UTE WAR 146 LTE UTE WAR 4
144 LTE UTE WAR 144 LTE UTE WAR 146 LTE UTE WAR 146 LTE UTE WAR 144 LTE UTE WAR 3
120 LTE UTE WAR 4
120 LTE UTE WAR 4
122 LTE UTE WAR 0
120 LTE UTE WAR 80 LTE UTE WAR 78 LTE UTE WAR 80 LTE UTE WAR 78 LTE UTE WAR 108 LTE UTE WAR 108 LTE UTE WAR 108 LTE UTE WAR 108 LTE UTE WAR 5
108 LTE UTE WAR 106 LTE UTE WAR 108 LTE UTE WAR 0
108 LTE UTE WAR 0
108 LTE UTE WAR 106 LTE UTE WAR 106 LTE UTE WAR 106 LTE UTE WAR 144 LTE UTE WAR 144 LTE UTE WAR 146 LTE UTE WAR 78 LTE UTE WAR 78 LTE UTE WAR 106 LTE UTE WAR 108 LTE UTE WAR 108 LTE UTE WAR 0
144 LTE UTE WAR 5
144 LTE UTE WAR 144 LTE UTE WAR 144 LTE UTE WAR 122 LTE UTE WAR 122 LTE UTE WAR 122 LTE.UTE WAR 5
78 LTE UTE WAR 80 LTE UTE WAR 5
78 LTE UTE WAR 3'
78 LTE UTE WAR 108 LTE UTE WAR 146 LTE UTE WAR 0
144 LTE UTE WAR
.3 144 LTE UTE WAR 4
144 LTE UTE WAR 4 -
146 LTE UTE WAR.
144 LTE UTE WAR 120 LTE UTE WAR..
120 LTE UTE.WAR 3
120 015015 WAR 79 LTE UTE WAR 80 LTE. UTE WAR 112 LTE UTE WAR 112 LTE'UTE WAR 4
110 LTE UTE WAR 2
110 014 014 WAR iii 013 013 WAR 111 LTE UTE WAR
-112 LTE UTE WAR 112 LTE UTE WAR 112 LTE UTE WAR 112 LTE UTE WAR 110 LTE UTE WAR 5
110 LTE UTE WAR 110 LTE UTE WAR 110 LTE UTE WAR 3
108 LTE UTE WAR 0
144 INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
,510XB 51OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 51MX 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
.510XB
.510XB 510XB.
510XP.
510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510 XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:50 Component: S/G B Page 42 of 46 Service QUERY: u2sga.qry Induced Degradation ROW COL VOLTS 136 64 0.14 136
'69 0.11 0.07 136 71 0.25 136 74 0.09 137 7
0.07 137 8
0.08 137 11 0.13 0.07 137 12 0.17 137 15 0.09 0.18 137 22 0.16 137
.24 0.11 0.15 137 38 0.08 0.13 137 63 0.15 0.15 137 68 0.06 137 69 3.21 1.09 137 70 0.08 137 73 0.06 137 77 0.08 138 2
0.06 138 4
0.09 138 9
0.08 0.'06 138 10 0.05 138 15 0.05 138 16 0.10 0.15 0.09 138 23 0.13 138 34 0.08 0.10 138 57 0.16 0.22 0.25 0.09 138 59 0.07 0.15 0.05 0.13 138 61 0.15 138.
66 0.17 138 67 0.15 138 69 0.14 138 70 1.17 0.12 0-35 138 72" 0.16 139 7
0.13 139 8
0.08 0.07 139 10
.0.14 0.10
.139 11 0.09 139.
14 0.19 139 17 0.17 0.13 139 42 0.11 139 43 0.09 139 49 0.20 139 51 0.10 139.54 0.11 139 57 0.10 139 58 0.06 139 60 0.08 0.16 139 61 0.06 139 64 0.07 0.06 139 65
.0.80 0.36 139 71 0.11 139 74 0.16 140 1
0.13 140 7
0.39 DEG 141 149 148 142 145 126 155 138 140 149 153 132 148 139 144 146 141 148 136 152 112 127 144 148 141 149 138 129 147 161 158 152.
146 146 143 148 138 148 144 142 140 154 136 158 117 143 142
.148 148 108 137 138 130
.138 143 156 149 147 147 149 141 145 142 149 145 135 149 150 160 153 151 136 144 159 107 136 136 140 73 CHN IND %TW P2 TWD 12 P2 TWD 10 P2 TWD 7 P2 TWD 18 P2 TWD 8 P2 TWD 6 P2 TWD 7 P2 TWD 10 P2 TWD 6 P2 TWD 14 P2 TWD 7.
P2 TWD 13 P2 TWD 13 P2 TWD 9 P2 TWD 12 P2 TWD 7 P2 TWD 11 P2 TWD 12 P2 TWD 12 P2 TWD 5 86 VOL P2 TWD 44 P2 TWD 7 P2 TWD 5 P2 TWD 7 P2 TWD 5 P2 TWD 7 P2 TWD 7 P2 TWD 5 P2 TWD 4 P2 TWD 5 P2 TWD 8 P2 TWD 12 P2 TWD 8 P2 TWD 10 P2 TWD 7 P2 TWD 9 P2 TWD 12 P2 TWD 16 P2 TWD 17 P2 TWD 7 P2 TWD 6 P2 TWD 11 P2 TWD 4 P2 TWD 10 P2 TWD 12
.P2 TWD 14 P2 TWD 11 P2 TWD 11 110 VOL P2 TWD 10 P2 TWD 24 P2 TWD 12 P2 TWD 10 P2 TWD 7 P2 TWD 6 P2 TWD 12 P2 TWD 9 P2 TWD 7 P2 TWD 1.4.
P2 TWD 13 P2 TWD 10 P2 TWD 9 P2 TWD-8 P2 TWD 16 P2 TWD 9 P2 TWD 9 P2 TWD 9 P2 TWD 5 P2 TWD 6 P2 TWD 12 P2 TWO 5 P2 TWD 6 P2 TWD 5 86 VOL P2 TWD 24 P2 TWD 10 P2 TWD 12 P2 TWD 10 LOCATION 009
-0.47 009
-0.42 012
-0.47 012
-0.44 010
-0.34 012
-0.37 014 70.39 012
+0.23 012
-0.39 012
-0.42 012
-0.42 012
+0.18 014
+0.03 014
-0.55 014
+0.18 012
-0.52 012
+0.21 009
-0.42 012
-0.44 010
-0.34 010
-0.34 010
-0.34 012
-0.36 010
-0.29 011
+0.39' 013
-0.41 012
+0.33 012
-0.39 012
+0.29 014
-0.45 012
-0.39 012
-0.42 013
+0.24 012
+0.18 014
+0.10 012
-0.52 012
+0.13 012
-0.47 014
-0.52 014
+0.21 012
+0.21 012
+0.34 014
+0.21 009
-0.44 014
-0.52 012
-0.44 012
-0.42 010
-0.34 010
-0.34 012
-0.32 010
-0.31 012
-0;37 010
-0.29 012
+0.29 012
.- 0.34 012
+0.26 012
-0.37 012
+0.23 012
+0.26 014
+0.18 012
-0.42 012
+0.26 014
+0.21 014
+0.18 014
ý0.52 012
-0.50 011
-0.36 009
-0.42 011
-0.36 014
+0.24 014
-0.50 011
+0.03 014
+0.29.
010
-0.39 010
-0.34 010
-0.36 010
-0.29 015
+0.68 010
+0.70 014
-0.39 EXT. EXT UTIL 1
UTIL 2
LTE UTE WAR LTE UTE WAR 3
LTE UTE WAR 3
LTE UTE WAR LTE UTE WAR LTE UTE WAR 4
LTE UTE WAR LTE UTE WAR LTE UTE WAR 3
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 4
- LTE UTE WAR LTE UTE WAR LTE UTE WAR 3
010 010 WAR LTE UTE WAR LAR LTE UTE WAR 4
LTE UTE WAR 3
LTE UTE WAR 7
LTE UTE WAR 3
LTE UTE WAR LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 5
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR.
5 LTE.UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 012 012 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 0
LTE UTE WAR LTE UTE WAR 3
.LTE UTE WAR 4
LTE UTE WAR LTE UTE WAR LTE UTE WAR 4
LTE UTE WAR-LTE UTE WAR 0
LTE UTE WAR-0 LTE UTE WAR
.LTE UTE WAR 5
LTE UTE WAR LTE UTE WAR 5
LTE UTE WAR 4
LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 4
010 010 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR CAL #
144 146 146 146 120 110 112 110 110 112 110 110 112 112 112 112 112 150 150 148 149 150 148 120 120 78 78 110 110 112 110 112 112 112 110 112 112 148 148 148 148 148 148 148 148 148 150 148 148 149 150 150 122 110 112 112 112 112 110 112.
110 110 148 150 150 150 148 150 148 148 148 150 148 148 149 150 120 122 80 LEG PROBE INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XP INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XP INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XP INLET 510XW INLET 510XB INLET 510XB INLET 510XB 82 P11 VOL 014 014 WAR LAR 109 INLET 510XP
AREVA NP Inc Customer Name: ONS2 Repi 01/20/09 02:11:51 Component:
S/G B Page 43 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS 0.20 140 11 0.19 140 14 0.18 0.12 0.08 140 15 0.12 140 16 0.98 0.31 0.15 0.08 140.35 0.08 140
.36 0.11 140 43 0.21 0.11 0.09 0.04 140 47 0.09 140 49 0.09 0.11 0.13 140 51 0.04 140 52 0.18 140 54 0.15 140 55 1.82 0.38 140 56 0.27 0.09 0.16 140 65 0.04 141 3
0.06 141 9
0.25 141 10 0.12 141 14 0.08 141 16 0.11 141 18 2.50 0.48 0.10 141 21 0.15 0.13 141 32 0.17 141 44 1.52 0.32 141 45 2.15 0.35 141 46 0.10 0.14 141 48 0.08 141 51 0.15 0.06 141 52 0.26 141 53 0.14 141 54 1.42 1.71 0.17 0.32 0.41 0.23 141 55 0.11 0.12.
0.15 141
- 56.
0.17 141 58 0.94 1.05 0.29 0.33 141 68 0.12 142 1
0.72 0.29 142 6
0.07 142 10 0'.07 142 14 0.13 0.08 142 16 0.06 i42 24 0.06
.142 28 2.20 0.15 0.48 142 29 0.16 142 30
'0.08 0.10 DEG CHN 144 P3 146 P2 150 P2 151 P2 152 P2 142 P2 112 86 144 P2 151 P2 152 P2 146 P2 146 P2 137 P2 149 P2 149 P2 153 P2 157 P2 139 P2 144 P2 139 P2 162 P2 147 P2 141 P2 98 6
140 P2 140 P2 150 P2 140 P2 158 P2 158 P2 144 P2 144 P2 149 P2 141 P2 25 P7 130 P2 143 P2 145 P2 148 P2 144 P2 103.122 136 P2 103 22 139 P2-150 P2 152 P2 152 P2 155 P2 153 P2 144 P2 143 P2 106" 118 102 146 153 P2 141 P2 137 P2 147 P2 149 P2 155 P2 150 P2 144 P2 116 62 107 110 141 P2 144 P2 151 P2
- 52.
62 123 P3 143 P2 142 P2 144 P2 145 P2 136 P2 149 P2
-27 P7 141 P2 137 P2 151 P2 142 P2 120. P2 IND TWO TWD TWO TWO TWO TWD VOL TWO TWO TWO TWO TWO TWD TWO TWO TWO TWO TWD TWD TWO TWD TWO TWO VOL TWO TWO TWD TWO TWO TWD TWD TWO TWD TWD VOL TWD TWD TWD TWO TWD VOL TWD VOL TWO TWD TWO TWO TWO TWO TWD TWO VOL VOL TWO TWD TWO TWO TWO TWD TWD TWD VOL VOL TWO TWD TWO VOL TWO TWO TWO TWD TWO
ýTWD TWO VOL TWO TWD TWD TWD TWO
%TW 15 14 14 10 7
9 21 12 7
7 9
15 9
7 3
7 7
9 10 3
14 12 24 19 8
13 3
5 18 9
6 9
28 8
12 11 13 22 22 8
12 7
11 5
19 11 14 22 26 17 9
9 12 14 21 23 9
22 6.
6 10 7
5 5
12 28 13 6
8 LOCATION 014
-0.39 012
+0.29 014
+0.21 012
-0.45 012
+0.21 012
-0.37 012
+0.24 012
+0.21 014
+0.13 014
'0.55 014
+0.16 012
-0.49 013
-0.57 014
-0.52 014
+0.10
-013
+0.21 009
.- 0.41 Oil
+0.26 012
-0.44 011
-0.39 009
-0.44 014
-0.52 014
+0.18 014
-0.47 014
-0.47 009
-.0.42 012
-0.42 012
+0.26 010
-0.34 013
+0.-31 012
+0.26 012
+0.29 014
-0.44 014
-0.49 014
-0.50 014
-0.49 014
+0.26 014
-0.47 014.
+0.26 014
-0.52 014
-0.50 014
-0.50 009
-0.47 009
-0.47 009
-0.42 012
-0.47 009
-0.44 009
-0.41 011
-0.34 009
-0.42 009
-0.44 012
-0.47 014
-0.47 009
-0.42 012
-0.44, 014
-0.47 014
+0;24 012
-0.42 014.
+0.26 014
-0.44 012
-0.42 010
-0.36.
012
-0.36 010
-0.36 012
-0.39 012
+0.39 014
-0.29 014
-0.31 012
+0.31 012
-0.39 014
-0.47 012
-0.36 012
-0.39 012
-0.47 014
-0.49 012
+0.23 014
-0.49 014 I+0.16 012
-0.47 012
+0.23 EXT EXT LTE =TE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 014 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 014 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 009 009 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 012 012 014 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE.
LTE UTE
.010 010 012 012 LTE UTE LTE UTE LTE UTE 014 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE, LTE UTE LTE UTE
.014 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE UTIL 1
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR UTIL 2
CAL # LEG 8
110 INLET 110 INLET 112 INLET 112 INLET 0
112 INLET 0
110 INLET 11 INLET 112 INLET 112 INLET 0
112 INLET 4
110 INLET 148 INLET 148 INLET 148 INLET 148 INLET 148 INLET 148 INLET 152 INLET 152 INLET 5
152 INLET 148 INLET 150 INLET 150 INLET 147 INLET 148 INLET 150 INLET 150 INLET 150 INLET
- 148 INLET 2
112 INLET 112 INLET 5
110 INLET 4
110 INLET 4
110 INLET 109 INLET 110 INLET 110 INLET 112 INLET 112 INLET 110 INLET 149 INLET 150 INLET 147 INLET 148 INLET 150 INLET 0
ISO INLET 150 INLET 148 INLET 4
148 INLET 150 INLET 148 INLET 149 INLET 149 INLET 150 INLET 150 INLET 150 INLET 150 INLET 148 INLET 148 INLET 5
148 INLET 150 INLET 149 INLET 149 INLET 150 INLET 150 INLET 4
122 INLET LAR 11 INLET 112 INLET 3
110 INLET 4
110 INLET 110 INLET 2
110 INLET 3
110 INLET
.3 110 INLET 109 INLET 110 INLET 110 INLET 112 INLET 110 INLET 4
110 INLET PROBE 510 XB 510XB 510XB 510XB 510XB 510XXB 510)P 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 5lOXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 51OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XP 510XB 510XP 510XB 510XB 510XB-510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 510XP 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP 51OXB 510XB 510XB 510XB 510XB
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:52 Component: S/G B Page 44 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS DEG CHN 142 34 142 41 142 42 142 43 142 44 142 45 142 46 142 47 142 50 142 53 142 54 142 55 142 57 142 60 142 62 143 8
143 10 143 12 143 i5 143 19 143 33 143 39 143 40 143 46 143 48 143 51 143 53 143 54 143 55 144 7
144 8
144 9
144 13 144 16 144 18 0.11 0.13 0.24 0.74 0.28 0.16 0.04 0.03 0.12 0.21 0.06 0.11 0.11 0.09 0.24 0.12 0.11 0.26 0.09 3.11 0.96 0.08 0.22 0.04 0.09 S.08 0.10 0.08 0.22 0.11 0.10 0.20 1.81 0.08 0.15 0.39 0.19 0.19 0.06 0.11 0.10 1.42 0.38 6.50 0.25 1.77 0.12 0.12 0.13 0.16 0.09 0.06 0.10 0.11 0.07 1.18 0.11 0.29 0.05 0.13 0.14 0.15 0.10 0.07 0.10 0.06 0.16 0.08 0.09 0.06 0.09 0.15 0.20 4.12 0.14 1.56 0.06 0.08 0.18 0.07 147 P2 138 P2 139 P2 129 38 143 P2 145 P2 154 P2 153 P2 148. P2 145 P2 140 P2 144 P2 151 P2 135 P2 141 P2 155 P2 143 P2 142 P2 149 P2 101 90 129 P2 134 P2 145 P2 133 P2 148 P2 118 P2 138 P2 146 P2 143 P2 143 P2 147 P2 143 P2 107 122 154 P2 145' P2 139 P2 150 P2 145 P2 153 P2 156 P2 135 P2 119 62 140 P2 90 46 144 P2 124 P2 149 P2 151 P2 151 P2 138 P2 156 P2 158 P2 148 P2 132 P2 138 P2 114.162 138 P2 137 P2 131 P2 139 P2 149 P2 138 P2 148 P2 142 P2 143 P2 151 P2 143 P2 151 P2 147 P2 160 P2 145 P2 139 P2 153 P2 99 90 143 P2 125 P2 159 P2 144 P2 146 P2 146 P2 IND TWO TWD TWD VOL TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWO TWO TWO TWO TWO TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD VOL TWD TWD TWD TWD TWO TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWO TWD TWD TWO TWD TWD TWD TWD TWD TWD TWD TWD TWD TWD VOL TWD TWD TWD TWD TWD TWD
%Ti 8
11 17 20 13 3
3 10 15 5
9 9
7 18 10 9
19 8
4i 6
16 4
7 6
8 6
16 9
9 15 7
13 26 15 14 5
8 8
25 17 52 11.
10 11 12 8
5 9
9 6
9 20 5
10 11 12 86 8
5 13
.7 8
5 8
11 14 11 50 5
7 14 6
W LOCATION 008 011 009 009 009 012 012 012 012 012 014 012 012 012
+
009 012 012 H
012 012 010 010 001 013 001 012
.012 013 012 014 014
+
014 014 H
014 012 013 014 009 009 012.-
010 011 010 010
.010 012 010 010 012 012 4
012 012 H
012 012 4
012 4
011
.4 014
+
012 014 4
,009
.009 009 009 014 4
009 014
.4 009
,009 012 012 012 012 010 010 010
+
010 012 012 010 4
014
-0.42
+0.24
-0.44
-0.36
-0.42
-0.44
-0.47
+0.23
-0.42
-0.42
+0.18
-0.42
-0.39
+0.29
-0.42
-0.42
+0.29
-0.39
+0.29
-0.39
-0.36
-0.26
-0.39
-0.26
+0.39
-0.36
-0.44
+0.34
-0.42
+0.29
-0.42
+0.29
-0.47
+0.31
-0.50
-0.47
-0.42
-0.41
-0.42
-0.39
-0.31
-0.34
-0.34
-0.41
-0.36
-0.36
-0.34
-0.37
-0.31
-0.36
-0.31
-0.39
-0.26
-0.26
-0. 31
-0.16
-0.39
- 0. 21
-0.39
-0.39
-0.39
-0.39
-0.18
-0.44
-0.21
-0.41
-0.42
-0.29
-0.39
-0.39
-0.37
-0.36.
-0.34
-0.39
-0.03
-0.34
-0.34
-0.31
-0.65
-0.41 EXT EXT UTIL 1
LTE UTE WAR LTE UTE WAR LTE UTE WAR 009 009 WAR LTE UTE' WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR-LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE.UTE WAR LTE UTE WAR LTE UTE WAR 010 010 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR
- LTE UTE
'WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 014 014 WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 010 010 WAR LTE UTE WAR 010 010 WAR LTE.UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 014 014 WAR
- LTE UTE WAR LTE'UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE ' WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR 010 010' WAR LTE UTE WAR LTE UTE. WAR LTE UTE WAR LTE UTE WAR LTE UTE WAR LTE UTE
'WAR UTIL 2
CAL 5
148 150 148 149 150 150 148 148 150
" 148
'148 2
150 148 148 150 148 148 150 150 149
.LAR 150 148 148 148 4
110 110 110 3
110
- 112, 112 112 112 149 150 150 150 150 148 148 148 0
150 149 150 147 148 LAR 148 150 150 112 110 112 112 112 110 3
110 109 110 110 112 110 112 110 148 150 6
150 148 150 150 150 3
150 150 148 4
148 149 3
150 LAR 150 148 0
150 112 110
- LEG PROBE INLET 510XB INLET 510XB INLET 510XB INLET 510XP INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 51OXP INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XP INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET.
- 510XB, INLET 510XB INLET 510XB INLET 510XP INLET 510XB INLET 510XP INLET 510XB INLET
'510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB-INLET 510XB INLET 510XB INLET 510XP.
INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 51OXE INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XP
- INLET, 51OXB INLET 510XB INLET 510XB INLET 510XB INLET 510XB INLET 510XB 144 144 144 144 144 144 144 144 144 144 144 144 144 144 21 22 23 24 29 31 33 36 37 45 47 49 50 51 144 52 144 53 145 13 145 14
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:53 Component: S/G B Page 45 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS DEG CHN IND %TW 145 16 0.12 135 P2 TWD 9
'145 17 2.84 102 150 VOL 0.15 142 P2, TWD 12 0..13 148 P2 TWD 11 0.23 146 P2 TWD 17 0.29 145 P2 TWD 20 145 22 0.07 153 P2 TWD 6 145
-27 0.07.
152 P2 TWD 6 0.14 141 P2 TWD 11 145 29 0.05 154 P2 TWD-4
.145 35 1.93 107 66 VOL.
0.27 138 P2 TWD 20 145 37 0.19 145 P2 TWD 15 145 40 0.14 149 P2 TWD 11 0.18 139 P2 TWD 13 145 47 0.15 145 P2 TWD 12 145 48 0.23 140 P2 TWD 16 146 12 0.15 140 P2 TWD 12 146 15 0.22 134 P2 TWD 16-0.14 139 P2 TWD 11
.0.07 143 P2 TWD 6 146 16 0..14 143 P2 TWD 11 0.16 147 P2 TWD 13 0.09 161 P2 TWD 8 146 18 0.08 149 P2 TWD 7 146 20 0.08 156 P2 TWD 7 146 21 0.08 146 P2 TWD 6 146 22 0.08 154 P2 TWD 7 146 26 0.24 141 P2 TWD 17 146 28 0.05 148 P2 TWD 4 146 31 0.10 150 P2 TWD 9 146 44 0.13
.143 P2 TWD 10 146 46 0.24 139 P2 TWD 17 146 47 0.08 153 P2 TWD 7 147 10 0.06 73 P2 TWD 5 147 13 0.17 147 P2 TWD 13 1-47 15 0.14 143 P2 TWD 11 0.09 151 P2 TWD 8
- 147 18 0.18 127 P2 TWD 13 147 20 0.06 149 P2 TWD 5 147 24 0.05 147 P2 TWD 4 147 27 0.07 148 P2 TWD 6 147 28 0.19.
147 P2 TWD 14 0.09 147 P2 TWD 7 147 30 0.11 129 P2 TWD 9 147 31
'0.24 144 P2 TWD 18 147 32 0.17 142 P2 TWD 12 147 33 0.09 138 P2 TWD 8 147 34 0.19 150 P2 TWD 14 147 42 0*17 143 P2 TWD 14 147 43 0.05 137 P2 TWD 4 148 1
0.13 145 P2 TWD 11 148 4
0.10 123 P2 TWD 8 148 8
0.08 138 P2 TWD 7 148 13 0.07 105 P2 TWD 6 148..16 0.19 144 P2 TWD 14 148 "19
-0.14 146 P2 TWD 11 148 24 0.14 148 P2 TWD 11 148 28 0.05 162 P2 TWD 4 148 31 0.13 138 P2 TWD 11.
148 33 0.22 138 P2 TWD 17 148 39 0.11 148 P2 TWD 9 148 40 0.10 142 P2 TWD 8 0.26 140 P2 TWD 18 149 1
0.66 115 P15 VOL 0.17 133 P3 TWD 14 149 2
0.10 142 P2 TWD 8 0.07 143 P2 TWD 6 149 3
0.06 "156 P2 TWD 5 149 14 0.07 135 P2 TWD 6 0.06
-140 P2 TWD 5 149 17 0.05 149 P2 TWD 5 149 20 0.19 147 P2 TWD 14 149 21 0.09 135 P2 TWD 8 149 27 1.21 100 142 VOL 0.11 98 P2 TWD 9 0.27 132 P2 TWD 20 150 1
0.10 78 P2 TWD 9 150 2
0.22 132 P2 TWD 17 150 4
1.66 105.106 VOL LOCATION 014
-0.47 014
-0:50 011
-0.34 012
-0.39 012
+0.34 014
-0.44 012
-0.42 014
-0.49 014
+0.31 009
-0.39 009
-0.44 009
-0.42 009
-0.39 012
-0.36 014
+0.29 012
-0.34 012
-0.36 013
-0.42 011
+0.34 012
-0.39 012
+0.39 011
-0.29 011
+0.37 014
-0.42 012
-0.39 012
-0:34 012
-0.39 014
-0.47 012
-0.37 012
-0.44 012
-0.39 012
-0.36 012
-0.34 012
-0.34 010
-0.26 012
-0.37 009
-0.41 012
-0.37 012.
-0.39 012
-0.36 011
-0.34 009
-0.42 014
+0.29
.014
-0.42 009
-0.39 009
-0.39 010 r0.39 010
-0.34 013
-0.42 012
-0.31 012
-0.36 015
+0.65 013
-0.39 013
- A0;36 010
-0.34 013
-0.41 012
-0.37 009
-0.39 012 0.34 010
-0.34 012
-0.37 012
-0.31 011
+0.36 012
-0.34 014
-0.39 014
-0.39
.012
-0.34 013
-0.34.
012
+0.47 012
-0.34 010
-0.26 009
-0.41 013
-0.39 009
-0.42 013
-0.47 011
-0.29 013
-0.42 010
+0.73
.012
-0.31 013
-0.39 EXT EXT LTE UTE 014 014 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 009 009 LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE
-LTE UTE LTE UTE.
LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE.
LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE
.LTE UTE LTE UTE
.LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 014 014 LTE UTE ILTE UTE LTE-UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE LTE UTE 013 013 LTE UTE LTE UTE LTE UTE LTE UTE 013 013 UTIL WAR WAR WAR.
WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR WAR 1
UTIL 2
CAL #
110 ill 112 112 112 112 110 ilO 110 150 149
-150 150 148 148 150 148 112 110 110 0
110' 112 112 112 112 112 110 112 148 148 150 148 148 150 4
110 112 112 112 110 110 148 0
150 148 4
148 148 150 148 4
150 148 150 148 116 114 114 4
116 114 116 148 148 150 150 150 148 148 LAR 115 8
116 114
- 114, 116 114 114 114 148 150 149 150 150 116 116 115 LEG INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET INLET INLET INLET.
INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET INLET PROBE 510XB 510XP
-510XB 510XB 510XB 510XBE 510XB 510XB 510XB 510XB 510XP 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB
-510XB
.510XB 510XB 510XB 510XB 510XB 510XB 51OXB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XE 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XB 510XP
AREVA NP Inc Customer Name: ONS2 Repl 01/20/09 02:11:54 Component:
S/G B Page 46 of 46 Service Induced Degradation QUERY: u2sga.qry ROW COL VOLTS DEG CHN IND %TW LOCATION 0.31 141 P2 TWD 22 013
-0.34 150 18 0.06 148 P2 TWD 5 010
-0.10 EXT EXT UTIL 1
UTIL 2
LTE UTE---WA LTE UTE WAR LTE UTE WAR 3
CAL # LEG 116 INLET 148 INLET
'PROBE 510OXB 510XB Total Tubes
- 2276 Total Records: 3602