Radiological Environmental Monitoring Program

- D 3.5.1 Table D 3.5.1-2 (page 1 of 1)

Reporting Levels for Radioactivity in Environmental Samples **

AIRBORNE FOOD RADIONUCLIDE PARTIUCLATE OR FISH MILK PRODUCTS ANALYSIS WATER GASES (pCi/rm) (pCi/kg, wet) (pCi/L) (pCi/kg, wet)

(pCVL)

H-3 20,000*

Mn-54 1,000 30,000 Fe-59 400 10,000 Co-58 1,000 30,000 Co-60 300 10,000 Zn-65 300, 20,1000 Sr-90

  • 8* 40 Zr-95 400 Nb-95 400 1-131 2* 0.9 3 100 Cs-1 34 30 10 1,000 60 1,000 Cs- 137 50 20 2,000 70 2,000 Ba-140 200 300 La-140 200 300
  • Values provided are for drinking water pathways. If no drinking water pathway exists, higher values are allowed,: as follows:

H-3 30,000 pCi/L (This is a 40 CFR 141 value)

Sr-90 12 pCi/L 1-131 20 pCi/L These reporting levels are associated only with the REMP requirements. The Ground Water Monitoring Program may involve unique reporting level criteria, independent of the REMP, and defined in station procedures.

Sr-90 is added to this table due to its potential pathway via ground water.

IPEC ODCM D 3.5.1 - 9 Revision 0

Radiological Environmental Monitoring Program D 3.5.1 Table D 3.5.1-3 (page 1 of 2)

Detection Capabilities for Environmental Sample Analysis (a) (e)

LOWER LIMIT OF DETECTION (LLD) (b) (c)

AIRBORNE PARTIUCLATE FOOD RADIONUCLIDE WATER OR GASES- FISH MILK PRODUCTS SEDIMENT ANALYSIS (pCi/L) (pCi/mr3) (pC Vkg, wet) (pCi/L) (pCi/kg, wet) (pCi/kg, dry)

Gross Beta 4 0.01 H-3 2,000 (d)

Mn,-54 15 130 Fe-59 30 260 Co-58 15 130 Co-60 Zn-65 15 30 260 zIz7;~

Sr-90 (f) 5 5000 Zr-95 15 Nb-95 15 1-131 1 (d) 0.07 60 Cs-134 15 0.05 130 15 .60 150 Cs-1 37 18 0.06 150 18 80 180 Ba-140 15 15 La-140 15 15 IPEC ODCM D 3.5.1 - 10 Revision 0