September 25, 2008 Mr. David A. Christian President and Chief Nuclear Officer Dominion Nuclear Connecticut, Inc.
Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711
SUBJECT:
MILLSTONE POWER STATION - UNIT NOS. 2 AND 3 - REQUEST FOR ADDITIONAL INFORMATION REGARDING DELETION OF E BAR DEFINITION AND REVISION TO THE REACTOR COOLANT SYSTEM SPECIFIC ACTIVITY (TAC NOS. MD8492 AND MD8493)
Dear Mr. Christian:
By letter dated March 25, 2008 (Agencywide Documents and Management System Accession No. ML080920781), Dominion Nuclear Connecticut, Inc. (DNC) submitted a license amendment request to revise the Millstone Power Station Unit Nos. 2 and 3 Technical Specifications (TS) regarding deletion of E Bar definition and the revision of the Reactor Coolant System Specific Activity TS.
The U.S. Nuclear Regulatory Commission staff has reviewed the information DNC provided and determined that additional information is required in order to complete the evaluation as set forth in the Enclosure.
The draft questions were sent to Mr. Bill Bartron, of your staff, to ensure that the questions were understandable, the regulatory basis for the questions was clear, and to determine if the information was previously docketed. During a discussion with your staff on September 22, 2008, it was agreed that you would provide a response by October 6, 2008.
Sincerely,
/ra/
Carleen J. Sanders, Project Manager Plant Licensing Branch I-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-336 and 50-423
Enclosure:
Request for Additional Information
Enclosure REQUEST FOR ADDITIONAL INFORMATION DELETION OF E BAR DEFINITION AND REVISION TO THE REACTOR COOLANT SYSTEM SPECIFIC ACTIVITY TECHNICAL SPECIFICATION MILLSTONE POWER STATION UNIT NOS. 2 AND 3 DOCKET NUMBERS 50-336 AND 50-423 By letter dated March 25, 2008 (Agencywide Documents and Management System Accession No. ML080920781), Dominion Nuclear Connecticut, Inc. (DNC) submitted a license amendment request (LAR) to revise the Millstone Power Station Unit 2 (MPS2) and Unit 3 (MPS3) Technical Specifications (TS) regarding deletion of E Bar definition and the revision of the Reactor Coolant System (RCS) Specific Activity TS. In order for the U.S. Nuclear Regulatory Commission (NRC) staff to complete its review of the documents listed above, the NRC staff needs the following additional information:
- 1.
The MPS2 TS limited condition of operation (LCO) 3.4.8 (page 3/4 4-13 of the MPS2 TS) currently includes non-applicability of Specification 3.0.4 in ACTION a only. However, insert (Attachment 2 of the LAR) for MPS2 TS LCO 3.4.8 relocates the non-applicability Specification 3.0.4 to proposed ACTION steps b as well as d. Proposed ACTION step b is equivalent to the current action step a. Provide an explanation for stating, Specification 3.0.4 is not applicable, in proposed MPS2 LCO 3.4.8 ACTIONS d.
- 2.
The current MPS3 TS LCO 3.4.8 ACTIONS a and b do not specify that Specification 3.0.4 is not applicable. Provide an explanation for stating, Specification 3.0.4 is not applicable, in proposed MPS3 LCO 3.4.8 ACTIONS b and d.
Millstone Power Station, Unit Nos. 2 and 3 cc:
Lillian M. Cuoco Senior Counsel Dominion Resources Services, Inc.
120 Tredegar Street, RS-2 Richmond, VA 23219 Edward L. Wilds, Jr., Ph.D.
Director, Division of Radiation Department of Environmental Protection 79 Elm Street Hartford, CT 06106-5127 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 First Selectmen Town of Waterford 15 Rope Ferry Road Waterford, CT 06385 Charles Brinkman, Director Washington Operations Nuclear Services Westinghouse Electric Company 12300 Twinbrook Pkwy, Suite 330 Rockville, MD 20852 Senior Resident Inspector Millstone Power Station c/o U.S. Nuclear Regulatory Commission P. O. Box 513 Niantic, CT 06357 Mr. J. W. "Bill" Sheehan Co-Chair NEAC 19 Laurel Crest Drive Waterford, CT 06385 Ms. Nancy Burton 147 Cross Highway Redding Ridge, CT 00870 Mr. Evan W. Woollacott Co-Chair Nuclear Energy Advisory Council 128 Terrys Plain Road Simsbury, CT 06070 Mr. Joseph Roy Director of Operations Massachusetts Municipal Wholesale Electric Company P.O. Box 426 Ludlow, MA 01056 Mr. J. Alan Price Site Vice President Dominion Nuclear Connecticut, Inc.
Millstone Power Station Building 475, 5th Floor Rope Ferry Road Waterford, CT 06385 Mr. Chris L. Funderburk, Director Nuclear Licensing &
Operations Support Dominion Resource Services, Inc.
Innsbrook Technical Center 5000 Dominion Boulevard Glen Allen, VA 23060-6711 Mr. Robert T. Griffin, Director Nuclear Safety & Licensing Dominion Nuclear Connecticut, Inc.
Millstone Power Station Building 475, 5th Floor Rope Ferry Road Waterford, CT 06385