ML082620110
| ML082620110 | |
| Person / Time | |
|---|---|
| Site: | Rancho Seco |
| Issue date: | 07/16/2008 |
| From: | Ellen Brown Sacramento Municipal Utility District (SMUD) |
| To: | NRC/FSME |
| References | |
| MPC&D 08-064 | |
| Download: ML082620110 (66) | |
Text
Rancho Seco Final Status Survey Summary Report July 16, 2008 Radwaste Piping System Survey Unit F8990421 Prepared By: Lj*
z FSS Engineer Date: 711612&
Reviewed By:
Date:
i41Z Lead FSS Engineer Approved By:
Date:_______
Dismantlement Qerintendent, Radiological
FINAL STATUS SURVEY
SUMMARY
REPORT Survey Unit:
F8990421, Radwaste Piping System Survey Unit
Description:
Operating History: This system transported liquid radioactive waste through the waste processing system. This system was designed to be contaminated. Operating records and the HSA support its status as radioactively contaminated system piping.
Site Characterization: Direct measurements were made of the interior surfaces of the system piping which confirmed the presence of plant-derived radionuclides. Direct measurements of the interior showed a mean gross activity level of 49,700,000 dpm!100 cm2 and a maximum value of 211,000,000 dpm/100 cm 2. Based on the classification procedure (DSIP-0020) and levels of gross activity reported, the system was determined to be a Class 1 system.
HSA Events: N/A Radioactive by design.
Survey Unit Design Information:
The Survey Unit Design Parameters are presented in Table 1 below. The survey unit and measurement locations are depicted on the maps in Attachment 1. Direct measurement locations were spaced at 15cm intervals and 59.5 m2 were scanned for 100% coverage.
The instrumentation used for the survey along with the MDC values are listed in Tables 2-1 and 2-2 in Attachment 2.
Page 2 of 41 FSS Summary Report F8990421
Table 1. Survey Unit Design Parameters Survey Design Value Comment Parameter Survey Area:
Survey Unit:
Class:
SU Area (m2):
Evaluator:
DCGL (dpm/100 cm2):
Area Factor:
Design DCGLemc (dpmII100 cm2):
LBGR (dpm/100 cm2):
Design Sigma (dpm/100 cm2):
Type I Error:
Type II Error:
Predominant Nuclide:
Sample Area (m2):
Scan Area (M2):
Scan Coverage (%):
Zl-, :
ZI-P :
Sign P:
Calculated Relative Shift:
Relative Shift Used:
N-Value:
Design N-Value + 20%:
Design Min Samples N:
Grid Spacing L:
F899 0421 1
59.5 Erin L. Brown 100000 N/A N/A 50000 100000 0.05 0.05 Cs-137 1000 59.5 100%
1.645 1.645 0.691462 0.5 0.5 74 89 89 0.8 Radwaste Piping System Structure Surface LTP Table 5-4 Gross Activity DCGL Class 1 Embedded Pipe Default = 50% DCGL Class 1 Class I Uses 3.0 if Relative Shift is
>3 NUREG-1575 Table 5-5 Class 1 Class 1 Page 3 of 41 FSS Summary Report F8990421
Survey Results:
A total of 1898 direct measurements were made in F8990421. The results including mean, median, standard deviation and range are shown in Table 2. One direct measurement was greater than the DCGL of 100,000 dpm/l 00cm 2. This measurement was evaluated and the dose contribution from this location was determined to be insignificant. Direct measurement activity ranged from 1919 to 137654 dpm/100 cm 2, based on the pipe detector efficiency.
Table 2. Direct Measurement Results Measurement ID Gross Activity
___(dpm/100 cm F8990421-MOOOIGI 5265 F8990421-MOO02GI 3613 F8990421-MOO03GI 3565 F8990421-MOO04GI 3232 F8990421-MOO05GI 3410 F8990421-MOO06GI 3391 F8990421-MOO07GI 3198 F8990421-M0008GI 3160 F8990421-MOO09Gl 3266 F8990421-MOOlOGI 3189 F8990421-MO013GI 3892 F8990421-MOO14GI 3184 F8990421-MOO15GI 3348 F8990421-MOO16GI 3406 F8990421-MOO17GI 3112 F8990421-MOO19GI 3044 F8990421-MOO20GI 3329 F8990421-M0025GI 5034 F8990421-M0026GI 2953 F8990421-M0027GI 3078 F8990421-M0028GI 3126 F8990421-M0029GI 2948 F8990421 -MOO30GI 3126 F8990421-M0031GI 2654 F8990421-M0032GI 2958 F8990421-M0033GI 3020 F8990421-M0034GI 3068 F8990421-M0037GI 3593 F8990421-M0038GI 3131 F8990421-M0039GI 2693 F8990421-MOO40GI 2943 F8990421-MOO41GI 3276 F8990421-M0042GI 2982 F8990421-M0043GI 2977 F8990421-M0044GI 3203 F8990421 -M0045GI 3232 F8990421-M0046GI 3733 F8990421-M0049GI 4350 Page 4 of 41 FSS Summary Report F8990421
F8990421-MOO50GI 3092 F8990421-MOO51GI 2929 F8990421-M0052GI 3035 F8990421-M0053GI 3054 F8990421-M0054GI 2958 F8990421-M0055GI 2972 F8990421 -M0056GI 3015 F8990421-M0057GI 2741 F8990421 -M0058GI 3801 F8990421-MOO60GI 4335 F8990421-MOO61GI 3545 F8990421-M0062GI 3719 F8990421-M0063GI 3550 F8990421-M0064GI 3627 F8990421-M0065GI 3362 F8990421-M0066GI 3198 F8990421-M0067GI 3627 F8990421-M0068GI 3536 F8990421-M0069GI 4986 F8990421-MOO70GI 8329 F8990421-MOO71GI 4412 F8990421-M0072GI 3449 F8990421-M0073GI 3473 F8990421-M0074GI 3425 F8990421-M0075GI 3632 F8990421-M0076GI 3251 F8990421-M0077GI 3382 F8990421-M0078GI 3078 F8990421-M0079GI 3377 F8990421-MOO80GI 3478 F8990421-MOO81GI 3487 F8990421-M0083GI 4013 F8990421-M0084GI 3290 F8990421-M0085GI 3574 F8990421-M0086GI 3449 F8990421-M0087GI 3304 F8990421-M0088GI 3560 F8990421-M0089GI 3430 F8990421-MOO90GI 3608 F8990421-M0091GI 3627 F8990421-M0092GI 3622 F8990421-M0093GI 3256 F8990421 -M0095GI 5241 F8990421-M0096GI 3598 F8990421-M0097GI 3386 F8990421-MOO98GI 3223 F8990421-M0099GI 3035 F8990421-MOIOOGI
-3844 F8990421-MOIOIGI 3536 F8990421-MO102GI 3531 F8990421-MO103GI 3492 F8990421-MO104GI 4422.
F8990421-MO105GI 3338 F8990421-MO106GI 3242 F8990421-MO107GI 3324 F8990421-MO108GI 3266 Page 5 of 41 FSS Summary Report F8990421
F8990421-MO109GI 3531 F8990421-MOIIOGI 3367 F8990421-M0111.GI 3285 F8990421-MO112GI 3203 F8990421-MO113GI 3304 F8990421-MO114GI 3767 F8990421-MO115GI 3536 F8990421-MO116GI 3295 F8990421-MO117GI 3430 F8990421-MO118GI 3632 F8990421-MO119GI 3468 F8990421-MO120GI 3338 F8990421-MO121GI 3430 F8990421-M0122GI 3950 F8990421-M0123GI 4648 F8990421-MO124GI 3786 F8990421-M0125GI 3507 F8990421-M0126GI 3492 F8990421-M0127GI 3434 F8990421-MO128GI 3415 F8990421-MO129GI 10072 F8990421-MO130GI 5405 F8990421-MO131GI 3377 F8990421-M0132GI 3304 F8990421-M0133GI 3598 F8990421-MO134GI 3579 F8990421-MO135GI 3362 F8990421-M0136GI 5462 F8990421-M0137GI 4427 F8990421-M0138GI 3844 F8990421-M0139GI 4094 F8990421-MO140GI 3598 F8990421-MO141GI 3261 F8990421-M0142GI 3362 F8990421-M0143GI 3290 F8990421-M0144GI 3377 F8990421-M0145GI 3382 F8990421-M0146GI 3444 F8990421-M0147GI 3540 F8990421-M0148GI 3213 F8990421-M0149GI 3434 F8990421-MOI5OGI 3492 F8990421-MO151GI 3401 F8990421-M0152GI 3516 F8990421-M0153GI 3425 F8990421-MO154GI 3155 F8990421-M0155GI 3516 F8990421-M0156GI 4947 F8990421-MO157GI 5424 F8990421-M0158GI 4827 F8990421-M0159GI 4706 F8990421-MO160GI 4875 F8990421-MO161GI 4451 F8990421-M0162GI 3974 F8990421-M0163GI 3512 F8990421-M0164GI 3271 Page 6 of 4 1.
FSS Summary Report F8990421
F8990421-MO165GI 3444 F8990421-MO166GI 3434 F8990421-M0167GI 3593 F8990421-M0168G1 3382 F8990421-MO169GI 3362 F8990421-MO170GI 3964 F8990421-MO171GI 3391 F8990421-M0172GI 3728 F8990421-M0173GI 5193 F8990421-M0174GI 3839 F8990421-M0175GI 3343 F8990421-M0176GI 3545 F8990421-MO177GI 3410 F8990421-M0178GI 2726 F8990421-M0179GI 3001' F8990421-MO180GI 2996 F8990421-MO181GI 2664 F8990421-M0182GI 3184 F8990421-M0183GI 3102 F8990421-MO184GI 3064 F8990421-M0185GI 3107 F8990421-M0186GI 3011 F8990421-M0187GI 3179 F8990421-M0188GI 3141 F8990421-M0189GI 2938 F8990421-MO190GI 2905 F8990421-MO191GI 2909 F8990421-M0192GI 2808 F8990421-M0193GI 3174 F8990421-M0194GI 3064 F8990421-M0195GI 3112 F8990421-M0196GI 3179 F8990421-M0197GI 3001 F8990421-M0198GI 3160 F8990421-M0199GI 3006 F8990421-MO200GI 3126 F8990421-MO201GI 3030 F8990421-M0202GI 3068 F8990421-M0203GI 3227 F8990421-M0204GI 3097 F8990421-M0205GI 3078 F8990421-M0206Gi 3184 F8990421-M0207GI 3223 F8990421-M0208GI 3348 F8990421-M0209GI 3242 F8990421-MO210GI 3025 F8990421-MO211GI
.3141 F8990421-M0212GI 3516 F8990421-M0213GI 3141 F8990421-M0214GI 3203 F8990421-M0215GI 2837 F8990421-M0216GI 3194 F8990421-M0217GI 3353 F8990421-M0218GI 3174 F8990421-M0219GI 3285 F8990421-M0220GI 3102 Page 7 of 41 FSS Summary Report F8990421
F8990421-M0221GI 3078 F8990421-M0222GI 3112 F8990421-M0223GI 3203 F8990421-M0224GI 3044 F8990421-M0225GI 3102 F8990421-M0226GI 2972 F8990421-M0227GI 3092 F8990421-M0228GI.
3285 F8990421-M0229GI 3232 F8990421-M0230GI 3194 F8990421-M0231GI 3001 F8990421-M0232GI 3020 F8990421-M0233GI 3039 F8990421-M0234GI 3088 F8990421-M0235GI 3073 F8990421-M0236GI 3473 F8990421-M0237GI 3242 F8990421-M0238GI, 3218 F8990421-M0239GI 3372 F8990421-M0240GI 3107 F8990421-M0241GI 3444 F8990421-M0242GI 3030 F8990421-M0243GI 3155 F8990421-M0244GI 3064 F8990421-M0245GI 3290 F8990421-M0246GI 3035 F8990421-M0247GI 3251 F8990421-M0248GI 3121 F8990421-M0249GI 3136 F8990421-M0250GI 3218 F8990421-M0251GI 3314 F8990421-M0252GI 3329 F8990421-M0253GI 3251 F8990421-M0254GI 3237 F8990421-M0255GI 3714 F8990421-M0256GI 3964 F8990421-M0257GI 3261 F8990421-M0258G1 3073 F8990421-M0259GI 3333 F8990421-M0260GI 3025 F8990421-M0261GI 3512 F8990421-M0299GI 3459 F8990421-MO300GI 3776 F8990421-M0301GI 3646 F8990421-M0302GI 3738 F8990421-M0303GI 4841 F8990421-M0304GI 4619 F8990421-M0305GI 2900 F8990421-M0306GI 2808 F8990421-M0307GI 3165 F8990421-M0308GI 2630 F8990421-M0309GI 2934 F8990421-MO310GI 3092 F8990421-M0311GI 3025 F8990421-M0312GI 3073 F8990421-M0313GI1 2934 Page 8 of 41 FSS Summary Report F8990421
F8990421-M0314GI 2924 F8990421-M0315GI 3049 F8990421-M0316GI 2895 F8990421-M0317GI 2924 F8990421-M0318GI 3160 F8990421-M0319GI 2856 F8990421-M0320GI 3020 F8990421-M0321GI 2962 F8990421-M0322GI 2813 F8990421-M0323GI 2905 F8990421-M0324GI 2909 F8990421-M0325GI 3088 F8990421-M0326GI 3126 F8990421-M0327GI 3035 F8990421-M0328GI 2914 F8990421-M0329GI 2909 F8990421-M0330GI 2929 F8990421-M0331GI 2770 F8990421-M0332GI 3039 F8990421-M0333GI 2861 F8990421-M0334GI 2962 F8990421-M0335GI 3131 F8990421-M0336GI 2755 F8990421-M0337GI 3015 F8990421-M0338GI 2909 F8990421-M0339GI 3078 F8990421-M0340GI 3020 F8990421-M0341GI 2837 F8990421-M0342GI 2905 F8990421-M0343GI 3039 F8990421-M0344GI 3049 F8990421-M0345GI 2803 F8990421-M0346GI 2890 F8990421-M0347GI 3064 F8990421-M0348GI 2852 F8990421-M0349GI 2929 F8990421-M0350GI 2962 F8990421-M0351GI 2616 F8990421-M0352GI 3194 F8990421-M0353GI 3984 F8990421-M0354GI 2934 F8990421-M0355GI 2953 F8990421-M0356GI 2871 F8990421-M0357GI 3603 F8990421-M0358GI 2669 F8990421-M0359GI 2553 F8990421-M0360GI 2962 F8990421-M0361GI 2818 F8990421-M0362GI 3112 F8990421-M0363GI 2914 F8990421-M0364GI 3049 F8990421-M0365GI 2847 F8990421-M0366GI 2914 F8990421-M0367GI 2842 F8990421-M0368GI 2987 F8990421-M0369GI 2837 Page 9 of 41 FSS Summary Report F8990421
F8990421-M0370GI 3001 F8990421-M0371GI 3073 F8990421-M0372GI 3121 F8990421-M0373GI 2755 F8990421-M0374GI 3068 F8990421-M0375GI 2972 F8990421-M0376GI 3160 F8990421-M0377GI 2982 F8990421-M0378GI 3044 F8990421-M0379GI 3160 F8990421-M0380GI 2972 F8990421-M0381GI 3367 F8990421-M0382GI 3526 F8990421-M0383GI 4176 F8990421-M0384GI 4109 F8990421-M0385GI 3540 F8990421-M0386GI 4287 F8990421-M0387GI 3256 F8990421-M0388GI 3131 F8990421-M0389GI 2847 F8990421-M0390GI 2871 F8990421-M0391GI 3102 F8990421-M0392GI 3420 F8990421-M0393GI 3483 F8990421-M0394GI 3372 F8990421-M0395GI 3502 F8990421-M0396GI 3343 F8990421-M0397GI 3434 F8990421-M0398GI 3382 F8990421-M0399GI 3579 F8990421-MO400GI 3545 F8990421-M0401GI 3618 F8990421-M0402GI 3540 F8990421-M0403GI 3589 F8990421-M0404GI 3526 F8990421-M0405GI 3892 F8990421-M0406GI 3719 F8990421-M0407GI 3627 F8990421-M0408GI 3598 F8990421-M0409GI 3439 F8990421-M0410GI 3468 F8990421-M0411GI 3497 F8990421-M0412GI 3396 F8990421-M0413GI 3618 F8990421-M0413GI 3776 F8990421-M0414GI 3487 F8990421-M0415GI 3579 F8990421-M0416GI 3536 F8990421-M0417GI 3430 F8990421-M0418GI 3512 F8990421-M0419GI 3516 F8990421-M0420GI 3540 F8990421-M0421-GI 3444 F8990421-M0422GI 3695 F8990421-M0423GI 3796 F8990421-M0424GI 3810 Page 10 of 41 FSS Summary Report F8990421
F8990421-M0425GI 3502 F8990421-M0426GI 3656 F8990421-M0427GI 3512 F8990421-M0428GI 3685 F8990421-M0429GI 3434 F8990421-M0430GI 3512 F8990421-M0431GI 3545 F8990421-M0432GI 3545 F8990421-M0433GI 3584 F8990421-M0434GI
.3357 F8990421-M0435GI 3656 F8990421-M0436GI 3666 F8990421-M0437GI 3357 F8990421-M0438GI 3492 F8990421-M0439GI 3353 F8990421-M0440GI 3627 F8990421-M0441GI 3338 F8990421-M0442GI 3579 F8990421-M0443GI 3266 F8990421-M0444GI 3516.
F8990421-M0445GI 3353 F8990421-M0457GI 3666 F8990421-M0458GI 4393 F8990421-M0459GI 5071 F8990421-M0460GI 4771 F8990421-M0461GI 4630 F8990421-M0462GI 4120 F8990421-M0490GI 5771 F8990421-M0491GI 4966 F8990421-M0492GI 4639 F8990421-M0493GI 3709 F8990421-M0494GI 3719 F8990421-M0495GI 3540 F8990421-M0496GI 3338 F8990421-M0497GI 3198 F8990421-M0498GI 3353 F8990421-M0499GI 3112 F8990421-MO500GI 3184 F8990421-MO501GI 3112 F8990421-M0502GI 3025 F8990421-M0503GI 2852 F8990421-M0504GI 2962 F8990421-M0505GI 3015 F8990421-M0506GI 3141 F8990421-M0507GI 3049 F8990421-M0508GI 3218 F8990421-M0509GI 3001 F8990421-MO510GI 2856 F8990421-MO511GI 3174 F8990421-M0512GI 3011 F8990421-M0513G1 3015 F8990421-M0514GI 3011 F8990421-M0515GI 3117 F8990421-M0516GI 2885 F8990421-M0517GI 2914 F8990421-M0518GI 3078 Page I11 of 41 FSS Summary Report F8990421
F8990421-M0519GI 3194 F8990421-M0520GI 3208 F8990421-M0521GI 3955 F8990421-M0522GI 5014 F8990421-MO523GI 6681 F8990421-M0524GI 4263 F8990421-M0525GI 3565 F8990421-M0526GI 3372 F8990421-M0527GI 3338 F8990421-M0528GI 3136 F8990421-M0529GI 2943 F8990421-M0530GI 2987 F8990421-M0531GI 2890 F8990421-M0532GI 2991 F8990421-M0533GI 3179 F8990421-M0534GI 5800 F8990421-M0535GI 11599 F8990421-M0536GI 4417 F8990421-M0537GI 3300 F8990421 -M0538GI 3150 F8990421-M0539GI 3078 F8990421-M0540GI 3276 F8990421-M0541GI 3001 F8990421-M0542GI 3295 F8990421-M0543GI 3304 F8990421-M0544GI 3314 F8990421-M0545GI 2962 F8990421-M0546GI 3242 F8990421-M0547GI 3025 F8990421-M0548GI 3030 F8990421-M0549GI 3218 F8990421-M0550GI 3179 F8990421-M0551GI 3304 F8990421-M0552GI 3097 F8990421-M0553GI 4864 F8990421-M0554GI 5501 F8990421-M0555GI 4019 F8990421-M0556GI 3779 F8990421-M0557GI 3861 F8990421-M0558GI 5219 F8990421-M0559GI 3401 F8990421-M0560GI 3063 F8990421-M0561GI 2662 F8990421-M0562GI 2675 F8990421-M0563GI 3267 F8990421-M0564GI 3217 F8990421-M0565GI 3405 F8990421-M0566GI 3352 F8990421-M0567GI 3888 F8990421-M0568GI 4315 F8990421-M0569GI 3957 F8990421-M0570G1 4417 F8990421-M0571GI 4387 F8990421-M0572GI 4157 F8990421-M0573GI 3812 F8990421-M0574GI 4075 Page 12 of 41 FSS Summary Report F8990421
F8990421-M0575GI 3099 F8990421-M0576GI 4650 F8990421-M0577GI 4433 F8990421-M0578GI 5531 F8990421-M0579GI 5468 F8990421-M0580GI 5015 F8990421-M0581GI 3598 F8990421-M0582GI 3543 F8990421-M0583GI 3342 F8990421-M0584GI 3030 F8990421-M0585GI 2875 F8990421-M0586GI 2655 F8990421-M0587GI 2507 F8990421-M0588GI 2931 F8990421-M0589GI 2892 F8990421-M0590GI 2307 F8990421-M0591GI 2294 F8990421-M0592GI 3050 F8990421-M0593GI 4152 F8990421-M0594GI 2948 F8990421-M0595GI 3044 F8990421-M0596GI 3237 F8990421-M0597GI 3039 F8990421-M0598GI 2982 F8990421-M0599GI 2982 F8990421-MO600GI 3160 F8990421-MO601GI 3097 F8990421-M0602GI 3203 F8990421-M0603GI 3126 F8990421-M0604GI 3247 F8990421-M0605GI 3170 F8990421-M0606GI 3194 F8990421-M0607GI 3300 F8990421-M0608GI 3290 F8990421-M0609GI 3044 F8990421-MO610GI 3107 F8990421-MO611GI 3256 F8990421-M0612GI 3030 F8990421-M0613GI 2895 F8990421-M0614GI 3227 F8990421-M0615GI 3348 F8990421-M0616GI 3357 F8990421-M0617GI 3998 F8990421-M0618GI 3502 F8990421-M0619GI 3237 F8990421-M0620GI 2895 F8990421-M0621GI 3661 F8990421-M0622GI 11564 F8990421-M0623GI 5199 F8990421 -M0624GI 3631 F8990421-M0625GI 2711 F8990421-M0626GI 2521 F8990421-M0627GI 2366 F8990421-M0628GI 2744 F8990421-M0629GI 3319 F8990421-M0630GI 414.1 Page 13 of 41 FSS Summary Report F8990421
F8990421-M0631GI 4653 F8990421-M0632GI 4469 F8990421-M0633GI 4269 F8990421-M0634GI 3930 F8990421-M0635GI 3635 F8990421-M0636GI 3654 F8990421-M0637GI 3339 F8990421-M0638GI 3326 F8990421-M0639GI 3618 F8990421-M0640GI 4009 F8990421-MO641GI 4469 F8990421-M0642GI
- 4903 F8990421-M0643GI 3874 F8990421-M0644GI 3572 F8990421-M0645GI 3339 F8990421-M0646GI 3247 SF8990421-M0647GI 3319 F8990421-M0648GI 3280 F8990421-M0649GI 3336 F8990421-M0650GI 3224 F8990421-M0651GI 3069 F8990421-M0652GI 2908 F8990421-M0653GI 3178 F8990421-M0654GI 3161 F8990421-M0655GI 2846 F8990421-M0656GI.
2810 F8990421-M0657GI 3848 F8990421-M0669GI 3680 F8990421-M0670GI 3266 F8990421-M0671GI 3324 F8990421-M0672GI 3449 F8990421.-M0673GI 3434 F8990421-M0674GI 3401 F8990421-M0675GI 3810 F8990421-M0676GI 3434 F8990421-M0677GI 3030 F8990421-M0678GI 3516 F8990421-M0679GI 3459 F8990421-M0680GI 3622 F8990421-M0681GI 3531 F8990421-M0682GI 3497 F8990421-M0683GI 3420 F8990421-M0684GI 3439 F8990421-M0685GI 3507 F8990421-M0686GI 3396 F8990421-M0687GI 3362 F8990421-M0688GI 3565 F8990421-M0689GI 3531 F8990421-M0690GI 3391 F8990421-M0691GI 3232 F8990421-M0692GI 3170 F8990421-M0693GI 3632 F8990421-M0694GI 3627 F8990421-M0695GI 3603 F8990421-M0696GI 3136 F8990421-M0697GI 3834 Page 14 of 41 FSS Summary Report F8990421
F8990421-M0698GI 3926 F8990421-M0699GI 2741 F8990421-MO700GI 3497 F8990421-MO701GI 3805 F8990421-M0702GI 3497 F8990421-M0703GI 3449 F8990421-M0704GI 3589 F8990421-M0705GI 3487 F8990421-M0706GI 3136 F8990421-M0707GI.
3849 F8990421-M0708GI 5848 F8990421-M0762GI 4383 F8990421-M0763GI 4730 F8990421-M0764GI 4990 F8990421-M0765GI 5072 F8990421-M0766GI 5034 F8990421-M0767GI 4350 F8990421-M0768GI 4509 F8990421-M0769GI 6912 F8990421-M0815GI 3940 F8990421-M0816GI 4277 F8990421-M0817GI 4224 F8990421-M0818GI 3844 F8990421-MO819GI 3646 F8990421-M0820GI 5419 F8990421-M0881GI 3598 F8990421-M0882GI 3362 F8990421-M0883GI 3550 F8990421-M0884GI 3584 F8990421-M0885GI 3757 F8990421-M0886GI 3497 F8990421-M0887GI 3873 F8990421-M0898GI 5487 F8990421-M0899GI 3285 F8990421-MO900GI 3184 F8990421-MO901GI 3329 F8990421-M0902GI 3242 F8990421-M0903GI 3083 F8990421-M0904GI 3565 F8990421-M0905GI 3213 F8990421-M0906GI 3468 F8990421-M0907GI 3526 F8990421-M0908GI 3868 F8990421-M0909GI 3333 F8990421-MO910GI 3324 F8990421-M0911GI 3324 F8990421-M0912GI 3362 F8990421-M0913GI 3386
- F8990421-M0914GI 3266 F8990421-M0915GI 3054 F8990421-M0916GI 3256 F8990421-M0917GI 3218 F8990421-M0918GI 3208 F8990421-M0919GI 3329
- F8990421-M0920GI 3324 F8990421-M0921GI 3179 Page 15 of 41 FSS Summary Report F8990421
.Y.
F8990421-M0922GI 3198 F8990421-M0923GI 3218 F8990421-M0924GI 3536 F8990421-M0925GI
- 3198 F8990421-M0926GI 3174 F8990421-M0927GI 3232 F8990421-M0928GI 3314 F8990421-M0929GI 3319 F8990421-M0930GI 3189 F8990421-M0931GI 3208 F8990421-M0932GI 3357 F8990421-M0933GI 3362 F8990421-M0934GI 3174 F8990421-M0935GI 3357 F8990421-M0936GI 3107 F8990421-M0937GI 3155 F8990421-M0938GI 3189 F8990421-M0939GI 7539 F8990421-M0940GI 3189 F8990421-M0941GI 3121 F8990421-M0942GI 2842 F8990421-M0943GI 2832 F8990421-M0944GI 3059 F8990421-M0945GI 2794 F8990421-M0946GI 2977 F8990421-M0947GI 3078 F8990421-M0948GI 2909 F8990421-M0949GI 3073 F8990421-M0950GI 3194 F8990421-M0951GI 3078 F8990421-M0952GI
'3184 F8990421-M0953GI 3088 F8990421-M0954GI 3150 F8990421-M0955GI 3261 F8990421-M0956GI 3068 F8990421-M0957GI 3078 F8990421-M0958GI 3256 F8990421;-M0959GI 3136 F8990421-M0960GI 3049 F8990421-M0961GI 2881 F8990421-M0962GI 3208 F8990421-M0963GI 3121 F8990421-M0964GI 2885 F8990421-M0965GI 3039 F8990421-M0966GI 3420 F8990421-M0967GI 3304 F8990421-M0968GI 3372 SF8990421-M0969GI 3145 F8990421-M0970GI 3092 F8990421-M0971GI 2866 F8990421-M0972GI 2842 F8990421-M0973GI 2953 F8990421-M0974GI 2885 F8990421-M0975GI 3025 F8990421-M0976GI 3382 F8990421-M0977G1 3261 Page 16 of 41 FSS. Summary Report F8990421
F8990421-M0978GI 3357 F8990421-M0979GI 3598 F8990421-M0980GI 3743 F8990421-M0981GI 3695 F8990421-M0982GI 3666 F8990421-M0983GI 3194 F8990421-M0984GI 3415 F8990421-M0985GI 5217 F8990421-M0986GI 6089 F8990421-M0987GI 3444 F8990421-M0988GI 3868 F8990421-M0989GI 3627 F8990421-M0990GI 3854 F8990421-M0991GI 3960 F8990421-M0992GI 4196 F8990421-M0993GI 4441 F8990421-M0994G1 5087 F8990421-M0995GI 5515 F8990421-M0996GI 5255 F8990421-M0997GI 4639 F8990421-M0998GI 4658 F8990421-M0999GI 4672 F8990421-MlOOOGI 5703 F8990421-M1001GI 5564 F8990421-M1002GI 4600 F8990421-M1003GI 4340 F8990421-M1004GI 3521 F8990421-MlOO5GI 3280 F8990421-M1006GI 2996 F8990421-M1OO7GI 3333 F8990421-MI008GI 2885 F8990421-MI009GI 3343 F8990421-MlOlOGI 3603 F8990421-M1011GI 3502 F8990421-M1012GI 3319 F8990421-M1013GI 3112 F8990421-M1014GI 2909 F8990421-MlOl5GI 3333 F8990421-M1016GI 3150 F8990421-MI017GI 3463 F8990421-MI018GI 3449 F8990421-M1019GI 3478 F8990421-M1020GI 3333 F8990421-M1021GI 3704 F8990421-M1022GI 3454 F8990421-M1023GI 3584 F8990421-M1024GI 3825 F8990421-M1025GI 3261 F8990421-M1026GI 4094 F8990421-M1027GI 4359 F8990421-M1028GI 3854 F8990421-M1029GI 3675 F8990421-M1030GI 3632 F8990421-MI031GI 3136 F8990421-M1032GI 5539 F8990421-M1033GI1 3242 Page 17 of 41 FSS Summary Report F8990421
F8990421-M1034GI 3391 F8990421-MI035GI 3112 F8990421-M1036GI 2967 F8990421-M1037GI 3247 F8990421-M1038GI 3126 F8990421-M1039GI 3049 F8990421-M1040GI 2775 F8990421-M1041GI 3025 F8990421-MI042GI 3174 F8990421-Ml043GI 17375 F8990421-M1044GI 11816 F8990421-M1045GI 5299 F8990421-M1046GI 3810 F8990421-M1047GI 3560 F8990421-M1048GI 3796 F8990421'M1049GI 3714 F8990421-M1050GI 3560 F8990421-M1051GI 3656 F8990421-M1052GI 3367 F8990421-M1053GI 3622 F8990421-M1054GI 4576 F8990421-M1055GI 3141 F8990421-M1056GI 2876 F8990421-M1057GI 3107 F8990421-M1058GI 2962 F8990421-M1059GI 3295 F8990421-M1060GI 3121 F8990421-MI061GI 3136 F8990421-M1062GI 2962 F8990421-M1063GI 3165 F8990421-M1064GI 3107 F8990421-M1065GI 3097 F8990421-M1066GI 3261 F8990421-M1067GI 14388 F8990421-M1068GI 7110 F8990421 -M1069GI 7553 F8990421-MI070GI 6618 F8990421-M1071GI 5014 F8990421-M1072GI 4427 F8990421-M1073GI 4807 F8990421-M1074GI 4229 F8990421-M1075GI 4070 F8990421-M1076GI 3714 F8990421-M1077GI 5419 F8990421-M1078GI 3237 F8990421-M1079GI 3131 F8990421-M1080GI 70116 F8990421-M1081GI 10766 F8990421-M1082GI 4966 F8990421-MI083GI 8589 F8990421-M1084GI 3382 F8990421-M1085GI 3194 F8990421-M1086GI 3266 F8990421-M1087GI 3256 F8990421-MI088GI 3011 F8990421-M1089GI 3304 Page 18 of 41 FSS Summary Report F8990421
F8990421-M1090GI 3251 F8990421-MI091GI 3208 F8990421-M1092GI 3011 F8990421-M1093GI 3271 F8990421-M1094GI 3068 F8990421-MI095GI 3391 F8990421-M1096GI 3382 F8990421-M1097GI 3410 F8990421-M1098GI 3348 F8990421-M1099GI 3478 F8990421-MllOOGI 3329 F8990421-MllOIGI 3121 F8990421-M1102GI 3030 F8990421-M1103GI 3213 F8990421-M1104GI 3324 F8990421-M1105GI 3198 F8990421-MI106GI 3121 F8990421-MI107GI 3266 F8990421-M1108GI 3083 F8990421-M1109GI 3791 F8990421-MiiiOGI 3757 F8990421-MliiiGI 4764 F8990421-M1112GI 4668 F8990421-M1113GI 4229 F8990421-M1114GI 3849 F8990421-M1115GI 2872 F8990421-M1116GI 2369 F8990421-M1117GI 2511 F8990421-M1118GI 2501 F8990421-MI119GI 2501 F8990421-M1120GI 2632 F8990421-MI121GI 2826 F8990421-M1122GI 2967 F8990421-M1123GI 2304 F8990421-MI124GI 2244 F8990421-M1125GI 2123 F8990421-M1126GI 2340 F8990421-M1127GI 2360 F8990421-M1128GI 2406 F8990421-M1129GI 2202 F8990421-M1130GI 2337 F8990421-M1131GI 2126 F8990421-M1132GI 2277 F8990421-M1133GI 2291 F8990421-M1134GI 2323 F8990421-M1135GI 2254 F8990421-M1136GI 2192 F8990421i-M1137GI 2379 F8990421-M1138GI 2386 F8990421-M1139GI 2218 F8990421-M1140GI 1959 F8990421-M1141GI 2172 F8990421-M1142GI 2281 F8990421-MI143GI 2350 F8990421 -M 1i44GI 2363 F8990421-M1145GI 2379 Page 19 of 41 FSS Summary Report F8990421
F8990421-M1146GI 2376 F8990421-M1147GI 2284 F8990421-M1148GI 2343 F8990421-M1149GI 2258 F8990421-M1150GI 2126 F8990421-M1151GI 2139 F8990421-M1152GI 2284 F8990421-M1153GI 2225 F8990421-M1154GI 2179 F8990421-M1155GI 2323 F8990421-M1156GI 2320 F8990421-M1157GI 2021 F8990421-M1158GI 2238 F8990421-M1159GI 2218 F8990421-M1160GI 2672 F8990421-M1161GI 6477 F8990421-M1162GI 4049 F8990421-M1163GI 2573 F8990421-MlI64GI 2103 F8990421-M1165GI 2323 F8990421-M1166GI 2314 F8990421-M1167GI 2192 F8990421-M1168GI 2429 F8990421-M1169GI 3651 F8990421-M1170GI 3582 F8990421-M1171GI 2836 F8990421 -Ml 172GI 2448 F8990421-M1173GI 2277 F8990421-M1174GI 2576 F8990421-M1175GI 2521 F8990421-M1176GI 2448 F8990421-M1177GI 2297 F8990421-M1178GI 2300 F8990421-M1179GI 2432 F8990421-M1180GI 2432 F8990421-M1181GI 2547 F8990421-MI182GI 2728 F8990421-M1183GI 2547 F8990421-M1184GI 2465 F8990421-M1185GI 2590 F8990421-M1186GI 2340 F8990421-M1187GI 2613.
F8990421-M1188GI 2583 F8990421-M1189GI 2527 F8990421-M1190GI 2287 F8990421-M1191GI 2475 F8990421-M1192GI 2465 F8990421-M1193GI 2304 F8990421-M1194GI 3096 F8990421-M1195GI 14982 F8990421-M1196GI 6145 F8990421-M1197GI 3881 F8990421-M1198GI 5347 F8990421-M1199GI 3549 F8990421-MI200GI 2504 F8990421-MI201GI 2129 Page 20 of 41 FSS Summary Report F8990421
F8990421-M1202GI 4822 F8990421-M1203GI 3247 F8990421-M1204GI 3232 F8990421-M1205GI 3088 F8990421-M1206GI 3406 F8990421-M1207GI 3083 F8990421-M1208GI 3030 F8990421-M1209GI 2977 F8990421-M1210GI 2885 F8990421-M1211GI 2741 F8990421-M1212GI 2905 F8990421-M1213GI 2789 F8990421-M1214GI 2876 F8990421-M1215GI 6951 F8990421-M1216GI 3329 F8990421-M1217GI 3102 F8990421-M1218GI 2818 F8990421-M1219GI 3242 F8990421-M1220GI 3208 F8990421-M1221GI 2972 F8990421-M1222GI 2871 F8990421-M1223GI 3261 F8990421-M1224GI 3695 F8990421-M1225GI 4099 F8990421-M1226GI 3237 F8990421-M1227GI 3092 F8990421-M1228GI 3801 F8990421-MI229GI 3213 F8990421-M1230GI 3049 F8990421-M1231GI 3088 F8990421-M1232GI 3247 F8990421-M1233GI 3208 F8990421-M1234GI 2914 F8990421-M1235GI 3011 F8990421-M1236GI 3121 F8990421-M1237GI 3049 F8990421-Ml238GI 3117 F8990421-M1239GI 3102 F8990421-M1240GI 3271 F8990421-M1241GI 4128 F8990421-M1242GI 3348 F8990421-M1243GI 3068 F8990421-M1244GI 2967 F8990421-M1245GI 2991 F8990421-M1246GI 2996 F8990421-M1247GI 2702 F8990421-M1248GI 2832 F8990421-M1249GI 2948 F8990421-M1250GI 3232 F8990421-M1251GI 3555 F8990421-M1252GI 5564 F8990421-M1253GI 15617 F8990421-M1254GI 4677 F8990421-M1255GI 3825 F8990421-M1256GI 3555 F8990421-M1257GI 3642 Page 21 of 41 FSS Summary Report F8990421
F8990421-M1258GI 3637 F8990421-MI259GI 3762 F8990421-M1260GI 3406 F8990421-M1261GI 3348 F8990421-M1262GI 3555 F8990421-M1263GI 4648 F8990421-M1264GI 6310 F8990421-M1265GI 3772 F8990421-M1266GI
.3762 F8990421-MI267GI 137654 F8990421-MI268GI 54154 F8990421-MI269GI 41962 F8990421-M1270GI 40077 F8990421-MI271GI 31923 F8990421-MI272GI 26962 F8990421-M1273GI 27500 F8990421-M1274GI 26038 F8990421-M1275GI 31231 F8990421-M1276GI 32500 F8990421-M1277GI 29115 F8990421-M1278GI 28154 F8990421-M1279GI 26962 F8990421-M1280GI 26423 F8990421-MI281GI 27308 F8990421-M1282GI 26923 F8990421-M1283GI 27808 F8990421-M1284GI 27500 F8990421-M1285GI 28923 F8990421-M1286GI 28692 F8990421-M1287GI 27962 F8990421-M1288GI 27731 F8990421-MI289GI 26346 F8990421-M1290GI 25923 F8990421-M1291GI 25769 F8990421-MI292GI 27269 F8990421-M1293GI 26885 F8990421-M1294GI 25154 F8990421-M1295GI 27038 F8990421-MM1296GI 28308 F8990421-M1297GI 28423 F8990421-M1298GI 31500 F8990421-M1299GI 38269 F8990421-M1300GI 29462 F8990421-M1301GI 29615 F8990421-M1302GI 28962 F8990421-M1303GI 28346 F8990421-MI304GI 29385 F8990421-M1305GI 30038 F8990421-M1306GI 34769 F8990421-M1307GI 37962 F8990421-M1308GI 38000 F8990421-M1309GI 35000 F8990421-MI310GI 33615 F8990421-MI311GI 33192 F8990421-M1312GI 32962 F8990421-M1313GI 36538 Page 22 of 41 FSS Summary Report F8990421
F8990421-M1314GI 32808 F8990421-M1315GI 33385 F8990421-M1316GI 32808 F8990421-M1317GI 32769 F8990421-M1318GI 30962 F8990421-M1319GI 34115 F8990421-M1320GI 38538 F8990421-M1321GI 39500 F8990421-M1322GI 33500 F8990421-M1323GI 41385 F8990421-M1324GI 42731 F8990421-M1325GI 46231 F8990421-MI326GI 49423 F8990421-M1327GI 45808' F8990421-M1328GI 27577 F8990421-M1329GI 30962 F8990421-M1330GI 29269 F8990421-M1331GI 7943 F8990421-MI332GI 8189 F8990421-M1333GI 7115 F8990421-M1334GI 3844 F8990421-M1335GI 4162 F8990421-M1336GI 3569 F8990421-M1337GI 3781 F8990421-M1338GI 5072 F8990421-M1339GI 4581 F8990421-M1340GI 4509 F8990421-M1341GI 6354 F8990421-M1342GI 3815 F8990421-M1343GI 3603 F8990421-M1344G1 8613 F8990421-M1345GI 3757 F8990421-M1346GI.
3531 F8990421-M1347GI 3704 F8990421-M1348GI 3709 F8990421-M1349GI 3420 F8990421-M1350GI 3569 F8990421-M1351GI 3589 F8990421-M1352GI 4316 F8990421-M1353GI 5414 F8990421-MI354GI
.15790 F8990421-M1355GI 4085 F8990421-M1356GI 3637 F8990421-M1357GI 4393 F8990421-M1358GI 3473 F8990421-M1359GI 3218 F8990421-M1360GI 3579 F8990421-M1361GI 3449 F8990421-M1362GI 3208 F8990421-M1363GI 3126 F8990421-M1364GI 3382 F8990421-M1365GI 3261 F8990421-M1366GI 3256 F8990421-M1367GI 3415 F8990421-M1368G1 11344 F8990421-M1369GI1 3427 Page 23 of 41 FSS Summary Report F8990421
F8990421-M1370GI 2887 F8990421-M1371GI 2778 F8990421 -Ml 372G1 2627 F8990421-M1373GI 2406 F8990421-M1374GI 2490 F8990421-M1375GI 2682 F8990421-M1376GI 2668 F8990421-M1377GI 2678 F8990421-M1378GI 2772 F8990421-M1379GI 2963 F8990421-M1380GI 3197 F8990421-M1381GI 3896 F8990421-M1382GI 4232 F8990421-M1383GI 4407 F8990421-M1384GI 4997 F8990421-M1385GI 5124 F8990421-M1386GI 5376 F8990421-M1387GI 5520 F8990421-M1388GI 5962 F8990421-M1389GI 5658 F8990421-M1390GI 5332 F8990421-M1391GI 5090 F8990421-M1392GI 4627 F8990421-M1393GI 3523 F8990421-M1393GI 4585 F8990421-M1394GI 5227 F8990421-M1395GI 9129 F8990421-M1396GI 7860 F8990421-M1397GI 5149 F8990421-M1398GI 3955 F8990421-M1399GI 3761 F8990421-MI400GI 3450 F8990421-M1401GI 2858 F8990421-M1402GI 3146 F8990421-M1403GI 3733 F8990421-M1491GI 4075 F8990421-M1492GI 3502 F8990421-M1493GI 3699 F8990421-M1494GI 3820 F8990421-M1495GI 3613 F8990421-M1496GI 3618 F8990421-M1497GI 3767 F8990421-M1498GI 6132 F8990421-M1499GI 5621 F8990421-M1509GI 3728 F8990421-MI510GI 3420 F8990421-MI511GI 2914 F8990421-M1512GI 2741 F8990421-M1513GI 3054 F8990421-M1514GI 3232 F8990421-M1515GI 3141 F8990421-M1516GI 2934 F8990421-M1517GI 3136 F8990421-M1518GI 3049 F8990421-M1519GI 2799 F8990421-M1520GI
.3092 Page 24 of 41 FSS Summary Report F8990421
F8990421-M1521GI 2885 F8990421-M1522GI 3068 F8990421-MI523GI 3165 F8990421-M1524GI 3068 F8990421-M1525GI 3059 F8990421-M1526GI 3117 F8990421-MI527GI 2996 F8990421-M1528GI 3170 F8990421-M1529GI 2958 F8990421-M1530GI 3184 F8990421-M1531GI 2871 F8990421-M1532GI 2977 F8990421-M1533GI 3092 F8990421-M1534GI 3001 F8990421-M1535GI 3064 F8990421-M1536GI 3271 F8990421-M1537GI 3141 F8990421-M1538GI 3025 F8990421-Ml539GI 3179 F8990421-M1540GI 3309 F8990421-M1541GI 3020 F8990421-Ml542GI 3198 F8990421-M1543GI 3203 F8990421-M1544GI 2832 F8990421-M1545GI 3170 F8990421-M1546GI 3011 F8990421-M1547GI 3251 F8990421-M1548GI 2977 F8990421-M1549GI 5000 F8990421-Ml550GI 4562 F8990421-M1551GI 2895 F8990421-M1552GI 2900 F8990421-M1553GI 3049 F8990421-Ml554GI 3179 F8990421-M1555GI 3039 F8990421-M1556GI 3030 F8990421-M1557GI 3121 F8990421-M1558GI 3107 F8990421-M1559GI 3097 F8990421-M1560GI 3068 F8990421-M1561GI 3362 F8990421-M1562GI 3237 F8990421-Ml563GI 3396 F8990421-M1564GI 3141 F8990421-M1565GI 3073 F8990421-M1566GI 3092 F8990421-M1567GI 3194 F8990421-M1568GI 3020 F8990421-M1569GI 3145 F8990421-M1570GI 3092 F8990421-M1571GI 3165 F8990421-M1572GI 3232 F8990421-M1573GI 3223 F8990421-M1574GI 2914 F8990421-M1575GI 3078 F8990421-M1576GI 3256 Page 25 of 41, FSS Summary Report F8990421
F8990421-M1577GI 2900 F8990421 -Ml 578GI 3362 F8990421-M1579GI 3189 F8990421-M1580GI 2943 F8990421-M1581GI 3121 F8990421-M1582GI 2991 F8990421-M1583GI 2991 F8990421-M1584GI 3006 F8990421-M1585G1 3545 F8990421-M1586GI 3338 F8990421-M1587GI 3338 F8990421 -Ml 588GI 3227 F8990421-M1589GI 3020 F8990421-M1590GI 3280 F8990421-M1591GI 2958 F8990421-M1592GI 2828 F8990421-M1593GI 3165 F8990421-M1594GI 3059 F8990421-M1595GI 5029 F8990421-M1596GI 3468 F8990421-M1597GI 3468.
F8990421-M1598G1 3719 F8990421-M1599GI 3550 F8990421-MI600GI 3613 F8990421-MI601GI 3666 F8990421-M1602GI 3507 F8990421-M1603GI 3916 F8990421-M1604GI 3574 F8990421-M1605GI
-3512 F8990421-M1606GI 3314 F8990421-M1607GI 3449 F8990421-M1608GI 3531 F8990421-M1609GI 3502 F8990421-M161OGI 3642 F8990421-M1611GI 3618 F8990421-M1612GI 3569 F8990421-M1613GI 3396 F8990421-M1614GI 3473 F8990421-M1615GI 3545 F8990421-M1616GI 3487 F8990421-M1617GI 3593 F8990421-M1618GI 3839 F8990421-M1619GI 3646 F8990421-M1620GI 3622 F8990421-MI621GI 3434 F8990421-M1622GI 3425 F8990421-M1623GI 3752 F8990421-M1624GI 3724 F8990421-M1625GI 3690 F8990421-M1626GI 3516 F8990421-M1627GI 3367 F8990421-M1628GI 3487 F8990421-M1629GI 3165 F8990421-M1630GI 3280 F8990421-M1631GI 3526 F8990421-M1632GI 3401 Page 26 of 41 FSS Summary Report F8990421
F8990421-M1633GI 3396 F8990421-M1634GI 3569 F8990421-M1635GI 3695 F8990421-M1636GI 3309 F8990421-M1637GI 3434 F8990421-M1638GI 3521 F8990421-M1639GI 3579 F8990421-M1640GI 3184 F8990421-M1641GI 3622 F8990421-M1642GI 3290 F8990421-M1643GI 3266 F8990421-M1644GI 3348 F8990421-M1645GI 3565 F8990421-M1646GI 3627 F8990421-M1647GI 3391.
F8990421-M1648GI 3430 F8990421-MI649GI 3415 F8990421-M1650GI 3271 F8990421-M1651GI 3309 F8990421-M1652GI 3401 F8990421-M1653GI 3767 F8990421-M1654GI 3550 F8990421-M1655GI 3637 F8990421-M1656GI 3521 F8990421-M1657GI 3300 F8990421-M1658GI 3386 F8990421-M1659GI 3459 F8990421-M1660GI 3661 F8990421-M1661GI 3502 F8990421-M1662GI 3690 F8990421-M1663GI 3020 F8990421-M1664GI 3507 F8990421-M1665GI 3271 F8990421-M1666GI 3247 F8990421-M1667GI 4263 F8990421-M1668GI 3391 F8990421-M1669GI 3724 F8990421-M1670GI 3357 F8990421-M1671GI 3724 F8990421-M1672GI 3160 F8990421-M1673GI 3478 F8990421-M1674GI 3353 F8990421-M1675GI 3584 F8990421-M1676GI 3666 F8990421-M1677GI 3752 F8990421-M1678GI 3772 F8990421-M1679GI 3256 F8990421-M1680GI 3680 F8990421-M1681GI 3319 F8990421-M1682GI 3526 F8990421-M1683GI 3748 F8990421-M1684GI 3165 F8990421-M1685GI 3391 F8990421-M1686GI 3685 F8990421-M1687GI 3483 F8990421-M1688GI 3333 Page 27 of 41 FSS Summary Report F8990421
F8990421-M1689GI 3613 F8990421-M1690GI 2580 F8990421-M1691GI 2287 F8990421-M1692GI 2682 F8990421-M1693GI 2810 F8990421-M1694GI 2665 F8990421-M1695GI 2090 F8990421-M1696GI 1975 F8990421-M1697GI 2146 F8990421-M1698GI 2205 F8990421-M1699GI 2284 F8990421-M1700GI 2287 F8990421-M1701GI 2938 F8990421-M1702GI 2547 F8990421-M1703GI 3030 F8990421-M1704GI 2251 F8990421-M1705GI 2652 F8990421-M1706GI 3013 F8990421-M1707GI 2912 F8990421-M1708GI 3027 F8990421-M1709GI 3168 F8990421-M171OGI 2895 F8990421-M1711GI 2954 F8990421-M1712GI 3842 F8990421-M1713GI 4443 F8990421-M1714GI 3240 F8990421-M1715GI 2813 F8990421-MI716GI 2169 F8990421-M1717GI 2258 F8990421-M1718GI 1965 F8990421-M1719GI 2070 F8990421-M1720GI 2018 F8990421-M1721GI 2028 F8990421-M1722GI 2120 F8990421-M1723GI 2113 F8990421-M1724GI 2189 F8990421-M1725GI 2097 F8990421-M1726GI 2202 F8990421-M1727GI 2396 F8990421-M1728GI 2133 F8990421-M1729GI 2251 F8990421-Ml730GI 2698 F8990421-M1731GI 3004 F8990421-M1732GI 3260 F8990421-M1733GI 2935 F8990421-M1734GI 2185 F8990421-M1735GI 2205 F8990421-M1736GI 2189 F8990421-M1737GI 2057 F8990421-M1738GI 1972 F8990421-M1739GI 2074 F8990421-M1740GI 2445 F8990421-M1741GI 2314 F8990421-M1742GI 2458 F8990421-M1743GI 2215 F8990421-M1744GI 2129 Page 28 of 41 FSS Summary Report F8990421
F8990421-M1745GI 2106 F8990421-M1746GI 2422 F8990421-M1747GI 2300 F8990421-M1748GI 2208 F8990421-M1749GI 2317 F8990421-M1750GI 2294 F8990421-M1751GI 2366 F8990421-M1752GI 2642 F8990421-M1753GI 2514 F8990421-M1754GI 3069 F8990421-M1755GI 2948 F8990421-M1756GI 3385 F8990421-Ml757GI 2682 F8990421-M1758GI 2596 F8990421-M1759GI 2379 F8990421-M1760GI 2567 F8990421-M1761GI 2438 F8990421-M1762GI 2429 F8990421-M1763GI 3204 F8990421-M1764GI 3884 F8990421-M1765GI 3122 F8990421-M1766GI 2685 F8990421-M1767GI 2225 F8990421-Ml768GI 2179 F8990421-M1769GI 2244 F8990421-M1770GI 6118 F8990421-M1771GI 3309 F8990421-M1772GI 3492 F8990421-M1773GI 3603 F8990421-M1774GI 3406 F8990421-M1775GI 3565 F8990421-M1776GI 3271 F8990421-M1777GI 3613 F8990421-M1778GI 3743 F8990421-M1779GI 3719 F8990421-Ml780GI 3699 F8990421-MI781GI 3415 F8990421-M1782GI 3584 F8990421-Ml783GI 3550 F8990421-M1784GI 3526 F8990421-M1785GI 3507 F8990421-M1786GI 3280 F8990421-M1787GI 3410 F8990421-M1788GI 3733 F8990421-MI789GI 3396 F8990421-M1790GI 3406 F8990421-M1791GI 3608 F8990421-M1792GI 3902 F8990421-M1793GI 3377 F8990421-M1794GI 3507 F8990421-M1795GI 3502 F8990421-M1796GI 3478 F8990421-M1797GI 3492 F8990421-M1798GI 3430 F8990421-M1799GI 3430 F8990421-M1800GI 3463 Page 29 of 41 FSS Summary Report F8990421
F8990421-M1801GI 3391 F8990421-M1802GI 3276 F8990421-M1803GI 3406 F8990421-M1804GI 3762 F8990421-M1805GI 3338 F8990421-M1806GI 3425 F8990421-MI807GI 3622 F8990421-M1808GI 3454 F8990421-M1809GI 3531 F8990421-MI810GI 3671 F8990421-MI811GI 3401 F8990421-M1812GI 3463 F8990421-M1813GI 3338 F8990421-M1814GI 3280 F8990421-M1815GI 3160 F8990421-M1816GI 3507 F8990421-M1817GI 3478 F8990421-M1818GI 3372 F8990421-M1819GI 3613 F8990421-M1820GI 3487 F8990421-M1821GI 3454 F8990421-M1822GI 3425 F8990421-M1823GI 3608 F8990421-M1824GI 3261 F8990421-M1825GI 3781 F8990421-M1828GI 6647 F8990421-M1829GI 4215 F8990421-M1830GI 03719 F8990421-M1831GI 3772 F8990421-M1832GI 3854 F8990421-M1833GI 3420 F8990421-M1834GI 3690 F8990421-M1835GI 3752 F8990421-MI836GI 3526 F8990421-M1837GI 3757 F8990421-M1838GI 3786 F8990421-M1839GI 3661 F8990421-M1840GI 3569 F8990421-M1841GI 3593 F8990421-M1842GI 3473 F8990421-M1843GI 3772 F8990421-M1844GI 3285 F8990421-M1845GI 3772 F8990421-M1846GI 3656 F8990421-M1847GI 3468 F8990421-M1848GI 3555 F8990421-M1849GI 3598 F8990421-M1850GI 3589 F8990421-M1851GI 3372 F8990421-M1852GI 3748 F8990421-M1853GI 3415 F8990421-M1854GI 3637 F8990421-M1855GI 3574 F8990421-M1856GI 3622 F8990421-M1857GI 3603 F8990421-M1858GI 3704 Page 30 of 41 FSS Summary Report F8990421
F8990421-M1859GI 3613 F8990421-M1860GI 3492 F8990421-M1861GI 3468 F8990421-M1862GI 3671 F8990421-M1863GI 3444 F8990421-M1864GI 3502 F8990421-M1865GI 6816 F8990421-M1866GI 3613 F8990421-M1867GI 3637 F8990421-M1868GI 3540 F8990421-M1869GI 3516 F8990421-M1870GI 3492 F8990421-M1871GI 3627 F8990421-M1872GI 3372 F8990421-M1873GI 3661 F8990421-M1874GI 3767 F8990421-M1875GI 3492 F8990421-M1876GI 3526 F8990421-M1877GI 3685 F8990421-M1878GI 3439 F8990421-M1879GI 3170 F8990421-M1880GI 3574 F8990421-M1881GI 3565 F8990421-M1882GI 3338 F8990421-M1883GI 3579 F8990421-M1884GI 3266 F8990421-M1885GI 3685 F8990421-M1886GI 3468 F8990421-M1887GI 4215 F8990421-M1888GI 3208 F8990421-M1889GI 3468 F8990421-MI890GI 3685 F8990421-M1891GI 3468 F8990421-M1892GI 3521 F8990421-M1893GI 3329 F8990421-M1894GI 3444 F8990421-M1895GI 3439 F8990421-M1896GI 3290 F8990421-M1897GI 3304 F8990421-M1898GI 3521 F8990421-M1899GI 3565 F8990421-M1900GI 3348 F8990421-M1901GI 3174 F8990421-M1902GI 3752 F8990421-M1903GI 3555 F8990421-M1904GI 8847 F8990421-M1905GI 4026 F8990421-M1906GI 2954 F8990421-M1907GI 2179 F8990421-M1908GI 2074 F8990421-M1909GI 1959 F8990421-MI910GI 1985 F8990421-M1911GI 2067 F8990421-M1912GI 2074 F8990421-M1913GI 2113 F8990421-M1914GI 2320 Page 31 of 41 FSS Summary Report F8990421
F8990421-M1915GI 2136 F8990421-M1916GI 2304 F8990421-M1917GI 2363 F8990421-M1918GI 2415 F8990421-M1919GI 2307 F8990421-MI920GI 2494 F8990421-M1921GI 2619 F8990421-M1922GI 2445 F8990421-M1923GI 2530 F8990421-M1924GI 2747 F8990421-M1925GI 2475 F8990421-M1926GI 2783 F8990421-M1927GI 4548 F8990421-M1928GI 2501 F8990421-M1929GI 2241 F8990421-MI930GI 2360 F8990421-M1931GI 2277 F8990421-M1932GI 2189 F8990421-M1933GI 2113 F8990421-M1934GI 2360 F8990421-M1935GI 2149 F8990421-M1936GI 2284 F8990421-M1937GI 2001 F8990421-M1938GI 2192 F8990421-M1939GI 2169 F8990421-M1940GI 1919 F8990421-M1941GI 2083 F8990421-M1942GI 2070 F8990421-M1943GI 2143 F8990421-M1944GI 2162 F8990421-M1945GI 2189 F8990421-M1946GI 2120 F8990421-M1947GI 2192 F8990421-M1948GI 2189 F8990421-M1949GI 2129 F8990421-M1950GI 2028 F8990421-M1951GI 2169 F8990421-M1952GI 1949 F8990421-M1953GI 2100 F8990421-M1954GI 2166 F8990421-M1955GI 2218 F8990421-M1956GI 2182 F8990421-M1957GI 2021 F8990421-M1958GI 2185 F8990421-M1959GI 2179 F8990421-M1960GI 1965 F8990421-M1961GI
.2103 F8990421-M1962GI 2330 F8990421-M1963GI 2307 F8990421-M1964GI 2291 F8990421-M1965GI 2215 F8990421-M1966GI 2517 F8990421-M1967GI 2494 F8990421-M1968GI 2465 F8990421-M1969GI 2215 F8990421-M1970GI 2494 Page 32 of 41 FSS Summary Report F8990421
F8990421-M1971GI 2402 F8990421-M1972GI 2481 F8990421-M1973GI 2409 F8990421-M1974GI 2392 F8990421-M1975GI 2373 F8990421-M1976GI 2527 F8990421-M1977GI 2337 F8990421-M1978GI 2307 F8990421-M1979GI 2373 F8990421-M1980GI 2258 F8990421-M1981GI 2251 F8990421-MI982GI 2218 F8990421-M1983GI 2465 F8990421-M1984GI 2442 F8990421-M1985GI 2593 F8990421-M1986GI 2826 F8990421-M1987GI 2912 F8990421-M1988GI 2902 F8990421-M1989GI 2780 F8990421-Ml990GI 2928 F8990421-M1991GI 2977 F8990421-M1992GI 2866 F8990421-M1993GI 3076 F8990421-M1994GI 2902 F8990421-M1995GI 2954 F8990421-M1996GI 3082 F8990421-M1997GI 3017 F8990421-M1998GI 2728 F8990421-M1999GI 2103 F8990421-M2000GI 2143 F8990421-M2001GI 2701 F8990421-M2002GI 2251 F8990421-M2003GI 2310 F8990421-M2004GI 2166 F8990421-M2005GI 2156 F8990421-M2006GI 2175 F8990421-M2007GI 2346 F8990421-M2008GI 2429 F8990421-M2009GI 2425 F8990421-M2010GI 2629 F8990421-M2011GI 2353 F8990421-M2012GI 2221 F8990421-M2013GI 2287 F8990421-M2014GI 2166 F8990421-M2015GI 2429 F8990421-M2016GI 2274 F8990421-M2017GI 2225 F8990421-M2018GI 2235 F8990421-M2019GI 2402 F8990421-M2020GI 2461 F8990421-M2021GI 2517 F8990421-M2022GI 2836 F8990421-M2023GI 2668 F8990421-M2024GI 2484 F8990421-M2025GI 2435 F8990421-M2026GI 2340 Page 33 of 41 FSS Summary Report F8990421
F8990421-M2027GI 2442 F8990421-M2028GI 2287 F8990421-M2029GI 2356 F8990421-M2030GI 2356 F8990421-M2031GI 2458 F8990421-M2032GI 2488 F8990421-M2033GI 2340 F8990421-M2034GI 2484 F8990421-M2035GI 2202 F8990421-M2036GI 2415 F8990421-M2037GI 2461 F8990421-M2038GI 2093 F8990421-M2039GI 2386 F8990421-M2040GI 2307 F8990421-M2041GI 2021' F8990421-M2042GI 2162 F8990421-M2043GI 2077 F8990421-M2044GI 2126 F8990421-M2045GI 2208 F8990421-M2046GI 2070.
F8990421-M2047GI 2267 F8990421-M2048GI 2195 F8990421-M2049GI 2116 F8990421 -M2050GI 2166 F8990421-M2051GI 2031 F8990421-M2052GI 55361 F8990421-M2053GI 5496 F8990421-M2054GI 4253 F8990421-M2055GI 3690 F8990421-M2056GI 3565 F8990421-M2057GI 3478 F8990421-M2058GI 3887 F8990421-M2059GI 3526 F8990421-M2060GI 4032 F8990421-M2061GI 3887 F8990421-M2062GI 3473 F8990421-M2063GI 4041 F8990421-M2064GI 4143 F8990421-M2065GI 3984 F8990421-M2066GI 3632 F8990421-M2067GI 3439 F8990421-M2068GI 3526 F8990421-M2069GI 3415 F8990421-M2070GI 3449 F8990421-M2071GI 3743 F8990421-M2072GI 3887 F8990421-M2073GI 4094 F8990421-M2074GI 4461 F8990421-M2075GI 5275 F8990421-M2076GI 4461 F8990421-M2077GI 91657 F8990421-M2078GI 21276 F8990421-M2079GI 8993 F8990421-M2080GI 3993 F8990421-M2081GI 3680 F8990421-M2082GI1 3540 Page 34 of 41 FSS Summary Report F8990421
F8990421-M2083GI 3680 F8990421-M2084GI 3560 F8990421-M2085GI 3892 F8990421-M2086GI 3752 F8990421-M2087GI 3844 F8990421-M2088GI 3854 F8990421-M2089GI 3998 F8990421-M2090GI 3666 F8990421-M2091GI 3357 F8990421-M2092GI 3637 F8990421-M2093GI 3738 F8990421-M2094GI 3786 F8990421-M2095GI 3666 F8990421-M2096GI 3319 F8990421-M2097GI 3675 F8990421-M2098GI 3107 F8990421-M2099GI 3598 F8990421-M2100GI 3882 F8990421-M2102GI 3825 F8990421-M2103GI 3724 F8990421-M2104GI 3878 F8990421-M2105GI 3646 F8990421-M2106GI 3796 F8990421-M2107GI 3618 F8990421-M2108GI 3357 F8990421-M2109GI 3560 F8990421-M2110GI 3781 F8990421-M2111GI 3434 F8990421-M2112GI 3512 F8990421-M2113GI 3487 F8990421-M2114GI 3728 F8990421-M2115GI 3560 F8990421-M2116GI 3353 F8990421-M2117GI 3304 F8990421-M2118GI 3685 F8990421-M2119GI 3815 F8990421-M2120GI 3695 F8990421-M2121GI 3776 F8990421-M2122GI 36195 F8990421-M2123GI 13396 F8990421-M2124GI 10462 F8990421-M2125GI 5193 F8990421-M2126GI 5564 F8990421-M2127GI 3357 F8990421-M2128GI 3926 F8990421-M2129GI 3521 F8990421-M2130GI 3709 F8990421-M2131GI 43719 F8990421-M2132GI 17693 F8990421-M2133GI 4634 F8990421-M2134GI 3805 F8990421-M2135GI 3675 F8990421-M2136GI 3232 F8990421-M2137GI 3579 F8990421-M2138GI 3357 F8990421-M2139GI 3555 Page 35 of 41 FSS Summary Report F8990421
F8990421-M2140GI 3632 F8990421-M2141GI 3449 F8990421-M2142GI 3651 F8990421-M2143GI 3661 F8990421-M2144GI 3589 F8990421-M2145GI 3353 F8990421-M2146GI 3367 F8990421 -M21 47GI 3651 F8990421-M2148GI 3454 F8990421-M2149GI 3632 F8990421-M2150GI 3463 F8990421-M2151GI 3613 F8990421-M2152GI 3565 F8990421-M2153GI 3406 F8990421-M2155GI 3637 F8990421-M2156GI 3420 F8990421-M2157GI 3353 F8990421-M2158GI 3622 F8990421-M2159GI 3627 F8990421-M2160GI 3882 F8990421-M2161GI 3521 F8990421-M2162GI 3964 F8990421-M2163GI 3984 F8990421-M2164GI 3565 F8990421-M2165GI 3699 F8990421-M2166GI 3969 F8990421-M2167GI 4687 F8990421-M2168GI 4441 F8990421-M2169GI 3627 F8990421-M2170GI 3887 F8990421-M2171GI 3988 F8990421-M2172GI 3921 F8990421-M2173GI 4432 F8990421-M2174GI 5111 F8990421-M2175GI 4215 F8990421-M2176GI 3666 F8990421-M2177GI 5843 F8990421-M2342GI 4759 F8990421-M2343GI 3805 F8990421-M2344GI 3926 F8990421-M2345GI 3815 F8990421-M2346GI 3603 F8990421-M2347GI 3849 F8990421-M2348GI 5202 F8990421-M2375GI 3550 F8990421-M2376GI 3401 F8990421-M2377GI 3651 F8990421-M2378GI 3550 F8990421-M2379GI 3752 F8990421-M2380GI 5092 F8990421-M2409GI 3145 F8990421-M2410GI 3256 F8990421-M2411GI 3213 F8990421-M2412GI 3218 F8990421-M2413GI 3223 F8990421-M2414GI 3073 Page 36 of 41 FSS Summary Report F8990421
F8990421-M2415GI 3261 F8990421-M2416GI 3025 F8990421-M2417GI 3382 F8990421-M2418GI 3430 F8990421-M2419GI 5308 F8990421-M2420GI 5193 F8990421-M2421GI 4224 F8990421-M2422GI 3449 F8990421-M2428GI 3685 F8990421-M2429GI 3121 F8990421-M2430GI 3555 F8990421-M2431GI 3463 F8990421-M2432GI 3276 F8990421-M2433GI 3396 F8990421-M2434GI 3420 F8990421-M2435GI 3536 F8990421-M2436GI 3536 F8990421-M2437GI 3473 F8990421-M2438GI 3478 F8990421-M2439GI 3324 F8990421-M2440GI 3748 F8990421-M2441GI 3227 F8990421-M2442GI 3449 F8990421-M2443GI 3492 F8990421-M2444GI 3603 F8990421-M2445GI 3680 F8990421-M2446GI 3642 F8990421-M2447GI 4321 F8990421-M2449GI 3549 F8990421-M2450GI 2491 F8990421-M2451GI 2248 F8990421-M2452GI 2087 F8990421-M2453GI 2432 F8990421-M2454GI 2172 F8990421-M2455GI 2120 F8990421-M2456GI 2097 F8990421-M2457GI 2389 F8990421-M2458GI 2241 F8990421-M2459GI 2323 F8990421-M2460GI 2376 F8990421-M2461GI 2307 F8990421-M2462GI 2294 F8990421-M2463GI 2438 F8990421-M2464GI 2314 F8990421-M2465GI 2330 F8990421-M2466GI 2363 F8990421-M2467GI 2353 F8990421-M2468GI 2340 F8990421-M2469GI 2442 F8990421-M2470GI 2507 F8990421-M2471GI 2415 F8990421-M2472GI 2258 F8990421-M2473GI 2156 F8990421-M2474GI 2123 F8990421-M2475GI 2070 F8990421-M2476GI 2044 Page 37 of 41 FSS Summary Report F8990421
F8990421-M2477GI F8990421-M2478GI F8990421-M2479GI F8990421-M2480GI F8990421-M2481GI F8990421-M2482GI F8990421-M2483GI F8990421-M2484GI F8990421-M2485GI F8990421-M2486GI F8990421-M2487GI F8990421-M2488GI Mean:
Median:
Standard Deviation:
Ranqe:
2258 2113 2152 2550 2264 2179 2212 2271 2363 2297 2363 2396 4609 3329 6930 1919-137654 Page 38 of 41 FSS Summary Report
-F8990421
Survey Unit Data Assessment:
The survey design required 1898 direct measurements for the Sign Test. The critical value and the results of the Sign Test are presented in Table 4. The sample mean and median values were less than the DCGL. The sample standard deviation was less than the design standard deviation so no additional samples were required.
Page 39 of 41 FSS Summary Report F8990421
Table 4. Data Assessment Results Survey Results Parameter Value Comment Material Background Used (dpm/100 cm 2):
Ambient Background Used (dprm/100 cm 2):
Actual Direct Measurements (N):
Median (dpm/100 cm2):
Mean (dpm/1.00 cm 2):
Direct Measurement Standard Deviation (dpm/100 cm2):
Total Standard Deviation (dpm/100 cm 2):
Maximum (dpm!IO00 cm 2):
Material Type:
Sign Test Final N Value:
S+ Value:
Critical Value:
Sufficient Samples Collected:
Maximum Value < DCGL:
Median Value < DCGL:
Mean Value < DCGL:
Maximum Value < DCGLemc:
Total Standard Deviation <= Sigma:
Pass the Sign Test?
Reject the Null Hypothesis?
Does the Survey Unit Pass All Criteria?
N/A N/A 1898 3329 4609 6930 6930 137654 N/A 1898 1897 985 Yes Investigate Yes Yes N/A Yes Yes Investigate Investigate Average Ambient BKG = 0 Based on samples and backgrounds.
Background Subtract Not Applied 1 measurement out of 1898
>DCGL Embedded Pipe Yes, SU passes sign test SU Passes Page 40 of 41 FSS Summary Report F8990421
Survey Unit Investigations and Results:
No investigations were required for either direct or scan measurements and no investigation results are reported. One direct measurement exceeded the DCGL of 100,000 dpm/100cm 2. This measurement was evaluated and the dose contribution from this location was determined to be insignificant.
ALARA Statement:
As stated in Chapter 4 of the LTP, as long as the residual activity within the survey unit is less than the DCGL (i.e. the survey unit average activity is less than the DCGL and the EMC criterion has been met), the ALARA criterion has been met.
Changes in Initial Survey Unit Assumptions:
The survey unit was designed as a Class 1 structure survey and the sample results are consistent with that classification. The variability of the survey results was less than the characterization data used for survey design.
==
Conclusion:==
The FSS of this survey unit was properly designed as a Class 1 survey based on Table 5-4 of the LTP. The required number of direct measurements was made and met the requirement of Table 5-6 of the LTP. No investigations were required.
The direct measurement data support rejection of the null hypothesis, providing high confidence that the survey unit satisfied the release criteria and that the data quality objectives were met.
It is concluded that survey unit F8990421 meets the release criteria of 10CFR20.1402.
Page 41 of 41 FSS Summary Report F8990421 Maps July 16, 2008 Survey Unit F8990421
(D 00 00 100 aý C) 0
- o
- ZIA,
.4 MATCH UN C
N t
30*1" ROOM 038 ED 3-3-20A EL -29""-O" EXPOSED PIPIN REMOVE,. TYP E
20 D-REOV ED7 EDal 3-337> REI OVE1 ROOM 037
--FO3-3-221 RE OVE 4'-0_
T
- E OONT BEI.OW/ RIGHT
[*1 REMOV 0 0,-S.
r I
RAD WASTE SUM-a I,,/
7/
7/
7//
K, di7/
K, 4?-0" 2
/-.
i
/
7
/
4
/
zzzz///,nt T,1r
- .0421-MI SHM 2 C 8,S (n 3c_199 REMA D t ~ThREM(
REM WD A-FD 3-1-21 EL -2r'-o"
.IROOM 04-0 FD-REMM/ED EL --24-1l TRENCH
`'TRENQH-ED-REMOVED EL -24'1-11i ROOM 039
-ED 3-2-22Aa EL. -20'-0" EL-22-O1 EF-9_0REME 0E REM 0E REMI 0
D
-ED 3-3--2m EL -.
-TREIN-tH-ED-REMO\\vED EL. -24'-1 I'
-ROOM 038 3Nrs 0
b ACID SUMP
--e I"-
00'o:
I
/ SI*QZ*22Ž 7-7 V.
I/
7,4-
=.
-t r
.Jim F
ELD 3-3-21 "L. -29"-0O" PLAN AT EL. -20'-O"
ýE 3-3_-2_7'\\-
(E-29-0 RErMOVED AATCIi LINE lONT AwVE LI'r SMUD 0.5 1
2 SACRAMENTO MUNICIPAL SCALE U'ILFIY DISTRICT METERS AUXILIARY BUILDING DRAINS RADWASTE EL. -20 RADWASTE SUMP F8990421 -M 1 4-21 SHEFT I OF 8 RC FILF, F'RQQ{3 RAYMOND F1 F899
C'D GO 0
00 00 a1 AO SMUD SACRAMENTO MUNICIPAL U1ILrrY DISTRICT IFILE! FSSSO AUXILIARY BUILDING DRAINS RADWASTE EL. -20 RADWASTE SUMP F8990421 -M1 421 SHEET 2 OF B RC RAYMOND o
.5 1
2 SCALE METERS
- 0 C'D 00 E
EXPOSED PIPING REMOVED, TYP 00 4ý
ý2 PLAN AT EL 0'-0" SMUD 0.5 1
2 W
SACRAMENTO MUNICIPAL SCALE ULrLITY DISTRICT METERS aIRLE!
FB99O AUXILIARY BUILDING DRAINS RADWASTE EL. 0 RADWASTE SUMP F8990421 -M1, 4-21 SHEET 3 OF a RC RAYMOND
CD (It 0
00 r
7 N~7 00 0
PLAN AT EL. 20'-0' PLAN AT EL. 40'-0"
.CALE SC1LE METERS SMUn SACRAMENTO MUNICIPAL U1LFnLrY DISTRICT RLE: F8990 AUXILIARY BUILDING DRAINS RADWASTE EL. 20', 40' RADWASTE SUMP-F8990421 -M 1 4-21 SHEET 4 OF" RC RAYMOND
(D 01 0
00 co PLAN AT EL. -20*-O"
- SMUI SACRAMENTO MUNICIPAL UILnrY CIs-RICT F!
- RAQ, AUXILIARY BUILDING DRAINS RADWASTE EL. -20 RADWASTE SUMP F8990421 -M 1 4-1 Il-FT-r F nrF A RC RAYMOND o.5 1 2
SCALE METERS
('D 0
0 0
Pt' PLAN AT EL. -20'-0" SCALE METERS
- mn SACRAMENTO. MUNICIPAL UILrLY DISTRICT RLE! FS§90 AUXILIARY BUILDING DRAINS RADWASTE EL. -20 RADWASTE SUMP F8990421 -M 1 4-21 SHEfET,[ OF B RC RAWOMOND
00 0
00 00 10 11
-,1 ROOM 040 FCO 3-2-14 E. -20'-O0 EXPOSED PIPING
- REMOVED, TYP PLAN AT EL. -20'-0" SCALE METE]RS AUXILIARY BUILDING DRAINS RADWASTE. EL. -20 RADWASTE SUMP F8990421-M1
0 00 CtJ 00 PLAN AT EL -20'-0'"
0
.5 1
2 F
SCALE MET*RS AUXILIARY BUILDING DRAINS RADWASTE EL. -20 RADWASTE SUMP F8990421 -M 1 4.21 SHEET 8 OF 8 RC
(D 0
00 cn 00 Ci N)
-A.
PIPINR
SUMMARY
SIZE "LEN"IN AREA 4"E 25 11 2.5 SM 2*10 7D LF 3.5 SM
- mo SACRAMENTO MUNICIPAL UliLrlY DISTRICT AUXILIARY BUILDING DRAINS RADWASTE HEADER 3 F8990421 -M2 FILE! F89O02I SHEET I OF,3 RC RAYMOND
Go a
007 14' il PIPING
SUMMARY
00 2"
aS LF 4.5 SM a
AUXILIARY BUILDING DRAINS w
SMUD RADWASTE HEADER 3 SLCRAMENO MUNICIPAL LR~rY DMRICTF8990421 -M2 RC RAYMOND
a'Q a
00 Uz
,.- z3 PIPING SUIMMARY 004 30 LF 1-9 SM kI~TO" 1601 8F SM AUXILIARY BUILDING DRAINS RADWASTE HEADER 3 SACRAMENTO MUNICIPAL DISTRICT F8990421 -M2 RIIF PMf4091 SeHltT 3 AF A RC RAYMOND
CD a
00J 00 100 Cd,
0 00 00 0*
PIPING SUMK4ARY SiZE LENOH AREA 6-0 35 LF 5 SM 4-°0 40 LF 4-SM 2*0 60 LF
- 4. SM
- SMU SACRAMENTO MUNICIPAL UTILFlY DISTRICT AUXILIARY BUILDING DRAIINS RADWASTE HEADER 2 F8990421 -M3 FILE! F69904-21 SIHEET 2 OF 3 RC RAYMIOND
00 00 C)
0\\
00 ITI 00 100 10 C)3 PIPING
SUMMARY
SIZE LENGTH AREA 4-0 40 LF
- 4. SM 2-0 80 LF
- 4. SM *mo SACRAMENTO MUNIOPAL
-LlLI'LY DISTRICT AUXILIARY BUILDING DRAINS RADWASTE HEADER 1 F8990421 -MM4 FILE! FS!90+21 SHEET 1 OF 3 RC RAYMOND
CD 0
00 00a PIPING
SUMMARY
SIZE LENGTH AREA 4.p 50 LF 5 SM 2-0 75 LF 4 SM
- smu!
SACRAMENTO MUNICIPAL LILFrLY DISTRICT AUXILIARY BUILDING DRAINS RADWASTE HEADER 1 F8990421 -M4 FILE! F3g90+21 SHEET. 2 O3F 3 RC RAYMOND
(D 00 0
00 00 110 Instrumentation July 16, 2008 Survey Unit F8990421
Table 2-1. Survey Unit Instrumentation Instrument Detector MDC Static MDC Scan Model; Serial No.
Model; Serial No.
(dpm/100 cm 2 )
(dpm/100 cm2 )
M2350; 189081 44-159; 238370 5250 N/A M2350; 189081 44-159; 238368 5250 N/A M2350; 142512 44-159; 201637 5250 N/A M2350; 142512 44-157; 215958 1680 N/A M2350; 142512 44-157; 201637 1680 N/A M2350; 189081 44-157; 201250 1680 N/A The MDC's listed represent the most conservative efficiencies for the survey conducted.
Table 2-2. Investigation Criteria and DCGL Value Parameter d
alue cm2)
(d pm/100 c2 Investigation Criteria - Direct 100000 Investigation Criteria - Scan N/A DCGLw 100000 DCGLEMC N/A Page 2 of 2 Att. 2 Instrumentation F8990421 Investigation July 16, 2008 Survey Unit F8990421 (none required)
Data Assessment July 16, 2008 Survey Unit F8990421
F8990421 Gross Activity Sample Results Quantile Plot DCGL = 100000 dpm/1 00cm 2 160,000 -
140,000 120,000 -
~~100,000 -*
80,000 -p1....
CD60,00 ww 20,000 2A~:
0 32 0
20 40 60 80 100 ITI Percentile ID Direct Measurements (dpm/100cm2) median 75th Percentile - - - - 50th Percentile
p CD It) 0 F8990421 Gross Activity Sample Results Scatter Plot DCGL = 100000 dpm/1O00cmn U
p p
Ca In CD Ca CD
-4 E
0 0
V 160000 140000 120000 100000 80000 60000 40000 20000 0
-20000
-40000 0
0 0
0 0
07 a 0
~-
25398 4609
-16180 T- ') 90 to 00 00 C1 C.
0 0
-r" -r-O(DOO 5
3 3 LO 104C M0)
(D0)0000D OCONO NWC IODOCD 40-oo 000000 00000000 00 00wD'0 tOVe N
o Sto N to 0 wI-tn.
qqf 04 Measurement Locations 00 10 Nc)
-A I o Gross Activity -
Average -
"+3SIDev ",.- -
"-3S1Dev"I
°41 F8990421 Gross Activity Frequency Plot 4ý1 DCGL = 100000 dpm/1 00crrf 1900
- 2, 1800 -
1 700 1600 S1 500 1400 6~100-_
1 3 0 0 5
1 200 u
T I r
00 T 1 T TyI C
1000 700 CD 500 040 400 200 000 Bins - Upper End Value (dpmll O0cm2)