ATTACHMENT (3)
MARKED UP TECHNICAL SPECIFICATION BASES PAGES Calvert Cliffs Nuclear Power Plant, Inc.
August 28, 2008
MSIVs B 3.7.2 BASES MODE 2 conditions in an orderly manner and without challenging unit systems.
SR 3.7.2.1 is the The Frequency for this SR is in accordance with the Inservice Testing Program.
The MSIVs are tested during each refueling outage in accordance with Reference 2, and sometimes during other cold shutdown periods.
The Frequency demonstrates the valve closure time at least once per refueling cycle.
Operating experience has shown that these components usually pass the SR when performed.
Therefore, the Frequency is acceptable from a reliability standpoint.
Q..lo~ r~ -h~e...
I~
11"'\\ o..cco r-c\\lJ...M....U-WI+L {L... If'5:.LNIO- --res.\\- ~,
1.
UFSAR ID I I
- 2. 3 2.
ASME, Boiler and Pressure Vessel Code,Section XI, 1989, "Rules for In-Service Inspection of Nuclear Power Plant Components," and ASME Operation and Maintenance Code Part 10, 1987, with 1988 Addenda REFERENCES CALVERT CLIFFS - UNITS 1 &2 B 3.7.2-5 Revision 14