ML082410180

From kanterella
Jump to navigation Jump to search

Closure of Confirmatory Action Letter NRR-07-006
ML082410180
Person / Time
Site: Waterford 
Issue date: 09/16/2008
From: Giitter J
Division of Operating Reactor Licensing
To: Walsh K
Entergy Nuclear South, Entergy Operations
Giitter J, NRR/DORL, 415-1453
References
TAC MD7293, NRR-07-006
Download: ML082410180 (4)


Text

September 16, 2008 Mr. Kevin T. Walsh Vice President, Operations Waterford 3 Entergy Nuclear South Entergy Operations, Inc.

17265 River Road Killona, LA 70057-3093

SUBJECT:

WATERFORD STEAM ELECTRIC STATION, UNIT 3 - CLOSURE OF CONFIRMATORY ACTION LETTER NRR-07-006 (TAC NO. MD7293)

Dear Mr. Walsh:

On March 20, 2007, the U.S. Nuclear Regulatory Commission (NRC) issued Confirmatory Action Letter (CAL) No. NRR-07-006 (Agencywide Documents Access and Management System (ADAMS) Accession No. ML070710563) regarding dissimilar metal welds in the pressurizer at Waterford Steam Electric Station, Unit 3. This letter acknowledges receipt of your letter dated July 28, 2008 (ADAMS Accession No. ML082120371) informing the NRC of actions taken by Entergy Operations, Inc (Entergy) in response to this CAL.

In the Entergy letter dated July 28, 2008, your staff stated that all committed actions in the CAL and the supporting commitment letter dated February 21, 2007 (ADAMS Accession No. ML070590205) have been completed. By letter dated May 29, 2008 (ADAMS Accession No. ML081540252), Entergy provided to the NRC a summary of the installation and satisfactory non-destructive examination of full structural weld overlays on one pressurizer surge nozzle, one pressurizer spray nozzle and three pressurizer safety/relief nozzles. By letter dated July 24, 2008 (ADAMS Accession No. ML082100076) Entergy provided a summary of mitigation actions taken on the remaining Alloy 82/182 butt welds associated with the pressurizer spray, surge, and relief lines.

Based on these letters, the NRC staff concluded that all the commitments listed in the CAL and the supporting commitment letter dated February 21, 2007, have been met for Waterford Steam Electric Station, Unit 3. No further response is required regarding the CAL and it is no longer necessary to implement enhanced inspection and leakage monitoring requirements for the reactor coolant system. This action closes CAL NRR-07-006 and Technical Assignment Control (TAC) No. MD7293.

Thank you for informing us of the actions documented in your letter. These actions may be examined during a future NRC inspection of your facility.

Current NRC guidance regarding CALs is contained in the NRC Enforcement Policy and the NRC Enforcement Manual, which are available at the NRC web site at http://www.nrc.gov/about-nrc/regulatory/enforcement.html (click on Enforcement Policy or Enforcement Guidance) or by contacting the Government Printing Office (GPO) toll-free at 1-888-293-6498. The GPO is open from 7:00 a.m. to 9:00 p.m. EST, Monday through Friday (except Federal holidays).

In accordance with Title 10 of the Code of Federal Regulations, Part 2, Section 390, of the NRC's "Rules of Practice," a copy of this letter will be made available electronically for public inspection in the NRC Public Document Room or from the NRC=s document system (ADAMS),

accessible from the NRC Web site at http://www.nrc.gov/reading-rm.html.

Sincerely,

/RA by Robert A. Nelson for/

Joseph G. Giitter, Director Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No.:

50-382 cc: See next page

ML082410180 OFFICE DCI/CPNB DCI/CPNB LPL4/PM LPL4/LA LPL4/BC NAME JCollins TChan NKalyanam BKS for GLappert MMarkley DATE 9/9/08 9/9/08 9/02/08 8/29/08 9/4/08 OFFICE DCI/D DRP/D RIV DORL/D NAME MEvans DChamberlain RCaniano for JGiitter RNelson for DATE 9/10/08 9/15/08 9/16/08

Waterford Steam Electric Station, Unit 3 (2/25/08) cc:

Senior Vice President Entergy Nuclear Operations P.O. Box 31995 Jackson, MS 39286-1995 Vice President, Oversight Entergy Nuclear Operations P.O. Box 31995 Jackson, MS 39286-1995 Senior Manager, Nuclear Safety

& Licensing Entergy Nuclear Operations P.O. Box 31995 Jackson, MS 39286-1995 Senior Vice President

& Chief Operating Officer Entergy Operations, Inc.

P.O. Box 31995 Jackson, MS 39286-1995 Associate General Counsel Entergy Nuclear Operations P.O. Box 31995 Jackson, MS 39286-1995 Manager, Licensing Entergy Operations, Inc.

Waterford Steam Electric Station, Unit 3 17265 River Road Killona, LA 70057-3093 Mr. Timothy Pflieger Environmental Scientist - Supervisor REP&R-CAP-SPOC Louisiana Department of Environmental Quality P.O. Box 4312 Baton Rouge, LA 70821-4312 Parish President Council St. Charles Parish P.O. Box 302 Hahnville, LA 70057 Chairman Louisiana Public Services Commission P.O. Box 91154 Baton Rouge, LA 70825-1697 Mr. Richard Penrod, Senior Environmental Scientist/State Liaison Officer Office of Environmental Services Northwestern State University Russell Hall, Room 201 Natchitoches, LA 71497 Resident Inspector Waterford NPS P.O. Box 822 Killona, LA 70057-0751 Regional Administrator, Region IV U.S. Nuclear Regulatory Commission 612 E. Lamar Blvd., Suite 400 Arlington, TX 76011-4125