Tech Spec Pages for Amendments 243 and 237 Regarding Single Supply Header Operation of the Buried Nuclear Service Water System
ML081980773
Person / Time
Site: Catawba  
(NPF-035, NPF-052)
Issue date: 07/30/2008
From:
NRC/NRR/ADRO/DORL/LPLII-1
To:
Stang J, NRR/DORL, 415-1345
Shared Package
ML081980768 List:
References
TAC MD6275, TAC MD6276
Download: ML081980773 (5)


Text

-'4-( -echnical Specifications The T.chni.cal Specifications contained in.Appendix A, as revised.through

.. AmendmentNo.243

  • ich.ar;eattached;-hereto, are-hereby incorporated into

-etnisrenewed operaing i.ense. Duke EneryCarolinas,.LLC shallt opterate the

.facility in accordancewith;the Techhncal Specifications.

(3)

UOdated Final Safety Analysis-Report The UpdatedFinal Safety Analysis Report supplement submitted pursuant to 10CR 421d,r a evised on Dece mber. 16.2002 describes certainfutur~e activities to be completed befo-re the "Periodof extended operation. Duke shall complete *theseactivities no later than.December:6, 2024, and'shall notify:the NRCin writingwhen implementation of these activities is complete and can be verifiedbY-NRCinSpection.

The UPda-d Final ISafety Ahalyis :Reprt supplement asreised on Decemb6er 6,202, descib`edabove, shall, 6e included-in-the nextzscheduled-updat6eto the Updated Fina

-SafetyAnalysis Report required by 10 CFR

.50.171(e)(4), following Missuan f-this renewed operating license. Until-that'"

updatelsiscomp lete, D ue my maecagst h rgasdsribed'in such supplement without prior commission approval, provided that Duke evaluates each such change pursuant to the crtera set forth in 10 CFR 50.59 and otherwise complies with the requirements in that section.

(4)

Antitrust Conditions Duke Energy Carolinas, LLC shall comply with the antitrust conditions delineated in Appendix C to this renewed operating license.

(5),

Fire Protection Program (Section 9.5.1, SER, SSER #2, SSER #3, SSER #4, SSER4#5)*

Duke Energy Carolinas,_LLC shall-implement and maintain in effect all

.provisions of the-approved flreprotectlon-program as described in -the Updated Final Safety Analysis Report, as amended, for the facility and as approved.in

-. thoeSER th*d-hgSUf`lpup*im-d-t.5, -sbjct-to the followinq *rovisi-n on:

The licensee may make changes to the approved fire protection program without-prior approval of the Commission only if those changes would not adversely affect the-ability to achieve and maintain safe shutdown in the event of a fire.

  • The parenthetical notation following the title of this renewedoperating license condition, denotes the section of the Safety Evaluation Report and/or its supplement wherein, this renewed license condition is discussed.

Renewed License No. NPF-35 Amendment No. 243 S"

(2)

Technical Specifications The Technical'Specifications contained in Appendix&A as revised through Amendmrt No

237 which are att'ached,,hereto' are hereby incorporated into this renewed-operting license. Duke Energy iCaroinas LLC shall operate'the facility in accordanceolwith the.Technical Specifications..

(3)i T. Updated Final Safety Anai*yani Rprt" The Upclated Final Safety Analysis Report supplement submitted pursuant to 10 CFR 54.21(d), as!revised on -December 16,.2002, describes certain future activitiesto.-be compLeiteb6efore th6 period of extended operation'. Duke shall complete these activities -no later than February24, 2026, and shall notify the NRC In writing When: implementation of these activities -is complete and can be verified by NRC inspection.

The-Updated Final Safety Analysis Report supplement as revised on.

December 16, 2002, described-abovej, shall be included in-the next scheduled update tothe Updited"EinalSafety Ana*lyis Reportrequired by 10 CFR 50.71 (e)(4), foit W tngIisuanceb of-thisrenewed operating libense. Until that update is complete, Duked-may makechangbs to the programs described in such supplement without prior Commission-approval, provided that Duke.evaluates.

  • each such change pursuant to the criteria set forth in 10 CFR 50.59 and otherwise complies with the requirements in that section.

(4)

Antitrust-Conditions Duke Energy Carolinas, LLC shall comply with the antitrust conditions delineated in Appendix C to this renewed operating license.

(5)

FireP'Protection Program (Section 9.5.1, SER, SSER#2, SSER #3, SSER #4, SSER #5)*

Duke Energy Carolinas, LLC shall implement and maintain in effect all provisions of -the approved fire protection-progrnamas described in the Updated FihalSafety.

Analysis Report, as amended, for the facility and as approved in the SER through Supplement 5, subject-to the following provision: ---

The-licensee may make changes to the approved fire protection program without prior approval of the Commission only if those changes would not adversely a ffectthe ability to achieve and. maintain safe shutdown in the event of afire..

  • The parenthetical notation following the title of this renewed operating license condition denotes the section of the Safety Evaluation Report and/or its supplements wherein this renewed license condition is discussed.

Renewed License No. NPF-52 Amendment No. 237

NSWS 3.7.:8 3,7 PLANT-9YSSTEMS-3.7.8 Nuclear Service Water System (NSWS)

LCO 3.7.8 APPLICABILITY:

Two NSWS trains shall be OPERABLE.

MODES 1, 2, 3, and 4.

I ACTIONS CONDITION REQUIREDIACTION COMPLETION TIME A.

One NSWS train A.1 NOTES------

inoperable.

1.

Enter applicable Conditions and Required Actions of LCO 318.1, "AC Sources-Operating," for emergency diesel generator made inoperable by NSWS.

2.

Enter applicable Conditions and RequiredActions of LC.46 "RCS Loops-7MWODE 4," for

..residual heat -removal-loops ma.de inoperable by NSWS.

Restore-NSWS train to 72 hours8.333333e-4 days <br />0.02 hours <br />1.190476e-4 weeks <br />2.7396e-5 months <br />' OPERABLE status.

(continued)

I Catawba Units-1--and -33-.8 z1 C.........ni A........ie-rnd nt Nos7243/237-

NSWS 3.7.8 ACTIONS (continued)

CONDITION REQUIRED ACTION O COMPLETION TIME B.


.NOTES----

1. Entryintothis Condition shall only be alldwed lfor pre-planhed activities as describedin-the Bases. of; this Specification.
2.

Immediately enter Condition A ofrthis LCOiflone or more NSWS components become inoperable While in this Condition and one NSWS train remains OPERABLE.

3.

Immediately enter LCO 3.0.3 if one or more NSWS components become inoperable while in this Condition and no NSWS train remains OPERABLE.

B.1 Restore NSWS supply header to OPERAJBLE status.

30 days One NSWS supply header inoperable due to NSWS being aligned for single supply header operation.

C.

Required Action and C.1 Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time of Condition A or B AND not met.

C.2 Be in MODE 5.

36 hours4.166667e-4 days <br />0.01 hours <br />5.952381e-5 weeks <br />1.3698e-5 months <br /> r

Catawba Units 1 and 2 3.7.8-2 aAmendmentNos. 243/237

NSWS 3.7.8 SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.8.1 NOTE--...----

Isolation of NSWS flow to individual components does not render the NSWS inoperable.

Verify each-NSWS -manual, power operated,-and 31 days automatic valve in the flowpath-servicing safety related equipment, that is not locked, sealed, or otherwise secured in position, is in the correct position.

SR 3.7.8.2

-NOTE Not required to be met for valves that are maintained in position to support NSWS single supply header operation.

Verify each NSWS automatic valve in the flow path that 18 months is not locked, sealed, or otherwise secured in position, actuates to the correct position on an actual or simulated actuation signal.

SR 3.7,8.3 Verify each NSWS pump starts automatically on an 18 months actual or simulated actuation signal.

Catawba Units 1 and 2 3.7.8-3 Amend ment-Nos.243/237