CY-TM-170-4160 Revision 1 Page 1 of 80 TMI Training and Reference Manual TMI RADIOLOGICAL GROUNDWATER PROTECTION PROGRAM (RGPP)
SAMPLE POINT DATA AND STANDARD CONTROL LIMITS 1.0 PURPOSE 1.1 This station procedure provides a method for control of station specific sample point analytical requirements and frequencies, as well as controlling notification levels for internal and external actions, and establishing for the external laboratory alert and high notifications to the station. Also established is a process for addition/deletion of monitoring locations and controlling the reporting matrix for this program.
1.2 This procedure provides guidance for the following:
RGPP sampling and analysis requirements.
Describes notification requirements for internal and external actions.
Process for changing monitoring locations.
Controlling the reporting matrix.
2.0 TERMS AND DEFINITIONS 2.1 RGPP - Radioactive Groundwater Protection Program.
2.2 PADEP - Pennsylvania Department of Environmental Protection.
2.3 LLD - Lower Limit of Detection as defined by the Off-Site Dose Calculation Manual.
2.4 NEI - Nuclear Electric Institute.
3.0 RESPONSIBILITIES 3.1 The station Chemistry/Environmental Department is the owner of the RGPP and is responsible for sampling, analysis, determining well locations, sampling requirements, and notifying station management of elevated groundwater radioactivity concentrations.
3.2 Operations Department is responsible for performing notifications IAW the Reportability Manual.
CY-TM-170-4160 Revision 1 Page 2 of 80 4.0 MAIN BODY 4.1 SAMPLE RGPP IAW ATTACHMENT 7.1, Sample Point List.
4.2 SEND samples to offsite vendor for environmental analysis.
4.3 MAINTAIN a list of sample point data sheets IAW ATTACHMENT 7.2, Sample Point Controlled Data Form.
4.4 If a new sample point is established, then USE appropriate ODCM values for default parameters IAW ATTACHMENT 7.3, Default RGPP Sample Point Data.
4.5 If a sample point is to be discontinued, then PROCESS removal of sample point IAW CY-AA-170-415, Controlled RGPP Sample Point Data and Standard Control Limits.
4.6 DOCUMENT any changes to sample points or parameters IAW CY-AA-170-415, Controlled RGPP Sample Point Data and Standard Control Limits.
5.0 RETURN TO NORMAL - None
6.0 REFERENCES
6.1 CY-AA-170-400. Radiological Groundwater Protection Program.
6.2 CY-AA-170-415, Controlled RGPP Sample Point Data and Standard Control Limits.
6.3 CY-AA-170-4000, RGPP Reporting Requirements.
7.0 ATTACHMENTS 7.1 ATTACHMENT 7.1, Sample Point List 7.2 ATTACHMENT 7.2, Sample Point Controlled Data Form 7.3 ATTACHMENT 7.3, Controlled RGPP Sample Point Data and Standard Control Limits
CY-TM-170-4160 Revision 1 Page 3 of 80 ATTACHMENT 7.1 Sample Point List Page 1 of 11 Sample frequency: M: Monthly, Q: Quarterly, S: Semi-Annual, T: Thrice Yearly, A: Annual, B: Biennial, L: Level Only Sample Number Coll.
Freq.
Sampling Description Approx.
Number of Samples per year Distance and Direction Required Analysis Analysis Freq.
Disposal Location MW-TMI-1D S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 East of Tower Desilt Basin Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-TMI-2D Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 4
1 1/2 West of MW-1 Tritium Gamma Strontium Q
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-TMI-3I S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 West of NW-B Well Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-TMI-4S S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 North of Warehouse 1 Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-TMI-4I S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 North of Warehouse 1 Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-TMI-5D S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 North of Warehouse 1 Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled
CY-TM-170-4160 Revision 1 Page 4 of 80 ATTACHMENT 7.1 Sample Point List Page 2 of 11 Sample Number Coll.
Freq.
Sampling Description Approx.
Number of Samples per year Distance and Direction Required Analysis Analysis Freq.
Disposal Location MW-TMI-5D S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 North of Warehouse 1 Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-TMI-6I S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 West of U-2 Reactor Building Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled Exclusion Zone MW-TMI-6D S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 West of U-2 Reactor Building Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled Exclusion Zone MW-TMI-7S S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 South of Dike, Center of Island Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-TMI-8S S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 North of Waste Storage Building Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-TMI-9I S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 South of SWSF in WHPF yard Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled
CY-TM-170-4160 Revision 1 Page 5 of 80 ATTACHMENT 7.1 Sample Point List Page 3 of 11 Sample Number Coll.
Freq.
Sampling Description Approx.
Number of Samples per year Distance and Direction Required Analysis Analysis Freq.
Disposal Location MW-TMI-9S S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 2
1 1/2 South of SWSF in WHPF yard Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-TMI-10S Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 4
1 1/2 West of Mechanical Draft Cooling Tower Tritium Gamma Strontium Q
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-TMI-10I Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 4
1 1/2 West of Mechanical Draft Cooling Tower Tritium Gamma Strontium Q
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-TMI-10D S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 2
1 1/2 West Side of Site Between Warehouse 2&3 Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-TMI-11S S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 2
1 1/2 South of PW-T-2 Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-TMI-12S Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 4
1 1/2 South of RW-2 Tritium Gamma Strontium Q
A B
Turbine Building sump or Drain Protected Area Isolation/
Microwave Zone MW-TMI-13S S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 2
1 1/2 West of B Cooling Tower Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled
CY-TM-170-4160 Revision 1 Page 6 of 80 ATTACHMENT 7.1 Sample Point List Page 4 of 11 Sample Number Coll.
Freq.
Sampling Description Approx.
Number of Samples per year Distance and Direction Required Analysis Analysis Freq.
Disposal Location MW-TMI-13I S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 West of B Cooling Tower Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-TMI-14I S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 At Hydrogen Staging Tanks Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled
- Exclusion Zone MW-TMI-14D S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 At Hydrogen Staging Tanks Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled
- Exclusion Zone MW-TMI-14S S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 At Hydrogen Staging Tanks Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled
- Exclusion Zone MW-TMI-16I S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 Inside Gate 1 Sallyport Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled
- Exclusion Zone MW-TMI-16D S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 Inside Gate 1 Sallyport Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled
- Exclusion Zone MW-TMI-17I S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 North Parking Lot Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled
CY-TM-170-4160 Revision 1 Page 7 of 80 ATTACHMENT 7.1 Sample Point List Page 5 of 11 Sample Number Coll.
Freq.
Sampling Description Approx.
Number of Samples per year Distance and Direction Required Analysis Analysis Freq.
Disposal Location MW-TMI-17D S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 2
1 1/2 North Parking Lot Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS)
Sump Owner Controlled MW-TMI-18D S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 2
1 1/2 Northeast of East Dike Catch Basin Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS)
Sump Owner Controlled MW-TMI-19I S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 South of RM-L-7 Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS)
Sump Owner Controlled MW-TMI-19D S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 South of RM-L-7 Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS)
Sump Owner Controlled 48S Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 4
1 1/2 South of Building 48 Tritium Gamma Strontium Q
A B
Industrial Waste Filter System (IWFS)
Sump Owner Controlled
CY-TM-170-4160 Revision 1 Page 8 of 80 ATTACHMENT 7.1 Sample Point List Page 6 of 11 Sample Number Coll.
Freq.
Sampling Description Approx.
Number of Samples per year Distance and Direction Required Analysis Analysis Freq.
Disposal Location E1-2 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 2
1 1/2 Visitor Center Well Tritium Gamma Strontium S
A B
N/A Offsite EDCB M
M B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 12 12 1/2 East Dike Settling Basin Tritium Gamma Strontium Q
Q B
N/A Owner Controlled GW-GP-1 Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 4
1 1/2 Within OCA, Refer to Map Tritium Gamma Strontium Q
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled GW-GP-6 Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 4
1 1/2 Within OCA, Refer to Map Tritium Gamma Strontium Q
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled GW-GP-8 Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 4
1 1/2 Within OCA, Refer to Map Tritium Gamma Strontium Q
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled GW-GP-9 Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 4
1 1/2 Within OCA, Refer to Map Tritium Gamma Strontium Q
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled GW-GP-12 Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/
gamma 4
1 1/2 Within OCA, Refer to Map Tritium Gamma Strontium Q
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled
- Exclusion Zone
CY-TM-170-4160 Revision 1 Page 9 of 80 ATTACHMENT 7.1 Sample Point List Page 7 of 11 Sample Number Coll.
Freq.
Sampling Description Approx.
Number of Samples per year Distance and Direction Required Analysis Analysis Freq.
Disposal Location MS-1 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 Area of 200K Off-Load Station Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MS-2 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 South of Chem Cleaning Building Tritium Gamma Strontium S
A B
Turbine Building sump or Drain Protected Area MS-3 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 Inside PAB-East of U-2 Control Building Tritium Gamma Strontium S
A B
Turbine Building sump or Drain Protected Area MS-4 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 Southeast Corner of Protected Area Tritium Gamma Strontium S
A B
Turbine Building sump or Drain Protected Area Isolation/
Microwave Zone MS-5 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 Inside PAB South End Tritium Gamma Strontium S
A B
Turbine Building sump or Drain Protected Area MS-7 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 North of IWTS Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled -
Exclusion Zone
CY-TM-170-4160 Revision 1 Page 10 of 80 ATTACHMENT 7.1 Sample Point List Page 8 of 11 Sample Number Coll.
Freq.
Sampling Description Approx.
Number of Samples per year Distance and Direction Required Analysis Analysi s Freq.
Disposal Location MS-8 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 East of U-2 FHB Tritium Gamma Strontium S
A B
Turbine Building sump or Drain Protected Area MS-19 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 South of B Cooling Tower Tritium Gamma Strontium S
A B
Turbine Building sump or Drain Owner Controlled Exclusion Zone MS-20 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 West of OESB Tritium Gamma Strontium S
A B
Turbine Building sump or Drain Protected Area MS-21 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 North of Diesel Building Tritium Gamma Strontium S
A B
Turbine Building sump or Drain Protected Area Isolation/
Microwave Zone MS-22 Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 4
1 1/2 West of U-1 Reactor Building Tritium Gamma Strontium Q
A B
Turbine Building sump or Drain Protected Area Inside RCA MW-1 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 East Side of Site Near MW-TMI-2D Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS)
Sump Owner Controlled
CY-TM-170-4160 Revision 1 Page 11 of 80 ATTACHMENT 7.1 Sample Point List Page 9 of 11 Sample Number Coll.
Freq.
Sampling Description Approx.
Number of Samples per year Distance and Direction Required Analysis Analys is Freq.
Disposal Location MW-2 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 At Cooling Tower Desilt Basin Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-3 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 East Side of Site Near MW-TMI-1D Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled MW-4 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 East Side of Site Near MW-3 Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled N2-1 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 Offsite-Goldsbo ro Marina Tritium Gamma Strontium S
A B
N/A Offsite NW-A S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 Southwest of Pretreatment Building Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled NW-B S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 Southwest of Pretreatment Building Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled NW-C S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 Southwest of Pretreatment Building Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled
CY-TM-170-4160 Revision 1 Page 12 of 80 ATTACHMENT 7.1 Sample Point List Page 10 of 11 Sample Number Coll.
Freq.
Sampling Description Approx.
Number of Samples per year Distance and Direction Required Analysis Analys is Freq.
Disposal Location NW-CW S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 Within OCA, Refer to Map Tritium Gamma Strontium S
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled OS-13B S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 West of U-2 Reactor Building Tritium Gamma Strontium S
A B
Turbine Building sump or Drain Protected Area OS-14 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 West of U-2 Turbine Building Tritium Gamma Strontium S
A B
Turbine Building sump or Drain Protected Area OS-18 Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 4
1 1/2 East of Building 222 Slab Tritium Gamma Strontium Q
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled OSF Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 4
1 1/2 West of OSF Building Tritium Gamma Strontium Q
A B
Industrial Waste Filter System (IWFS) Sump Owner Controlled RW-1 S
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 2
1 1/2 Aux Boiler Area Tritium Gamma Strontium S
A B
Turbine Building sump or Drain Protected Area RW-2 Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 4
1 1/2 Aux Boiler Area Tritium Gamma Strontium Q
A B
Turbine Building sump or Drain Protected Area Isolation/
Microwave Zone
CY-TM-170-4160 Revision 1 Page 13 of 80 ATTACHMENT 7.1 Sample Point List Page 11 of 11 Sample Number Coll.
Freq.
Sampling Description Approx.
Number of Samples per year Distance and Direction Required Analysis Analys is Freq.
Disposal Location SW-E-1 Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 4
1 1/2 East Shore of Island near MW-TMI-2D Tritium Gamma Strontium Q
A B
N/A Owner Controlled SW-E-2 Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 4
1 1/2 East Shore of Island near Fish ladder catwalk Tritium Gamma Strontium Q
A B
N/A Owner Controlled SW-E-3 Q
A B
250 Ml Br. Amb 4 L acid to pH 2 0.5 L acid inc. w/ gamma 4
1 1/2 East Shore of Island at South Bridge Tritium Gamma Strontium Q
A B
N/A Owner Controlled
CY-TM-170-4160 Revision 1 Page 14 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 1 of 66 Sample Point: MW-TMI-1D Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: No Other:
Location owner controlled; East of Tower Desilt Basin Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally f pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 15 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 2 of 66 Sample Point: MW-TMI-2D Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; West of MW-1 Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium Q
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 16 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 3 of 66 Sample Point: MW-TMI-3I Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location ownr controlled; West of NW-B well Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 17 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 4 of 66 Sample Point: MW-TMI-4S Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; North of Warehouse 1 Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 18 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 5 of 66 Sample Point: MW-TMI-4I Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; North of Warehouse 1 Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 19 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 6 of 66 Sample Point: MW-TMI-5D Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; North Warehouse 1 Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 20 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 7 of 66 Sample Point: MW-TMI-6I Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; West of U-2 Reactor Building Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 21 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 8 of 66 Sample Point: MW-TMI-6D Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; West of U-2 Reactor Building Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 22 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 9 of 66 Sample Point: MW-TMI-7S Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; South of dike at center of island Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 23 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 10 of 66 Sample Point: MW-TMI-8S Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; North of waste storage building Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 24 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 11 of 66 Sample Point: MW-TMI-9I Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; South of SWSF in WHPF Yard)
Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 25 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 12 of 66 Sample Point: MW-TMI-9S Date Changed: 8/28/2007 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; South of SWSF in WHPF Yard Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 26 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 13 of 66 Sample Point: MW-TMI-10S Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: Yes Potential Drinking Water Source: no Other:
Location owner controlled; West mech draft cooling tower Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium Q
2000 4000 5000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 27 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 14 of 66 Sample Point: MW-TMI-10I Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: Yes Potential Drinking Water Source: no Other:
Location owner controlled; West mech draft cooling tower Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium Q
2000 4000 5000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 28 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 15 of 66 Sample Point: MW-TMI-10D Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; West mech draft cooling tower Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 29 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 16 of 66 Sample Point: MW-TMI-11S Date Changed: 8/28/2007 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location protected area; South of PW-T-2 Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 30 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 17 of 66 Sample Point: MW-TMI-12S Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: Yes Potential Drinking Water Source: no Other:
Location protected area; South of RW-2 Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium Q
2000 4000 5000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 31 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 18 of 66 Sample Point: MW-TMI-13S Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: Yes Potential Drinking Water Source: no Other:
Location owner controlled; West of B cooling tower Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 32 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 19 of 66 Sample Point: MW-TMI-13I Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: Yes Potential Drinking Water Source: no Other:
Location owner controlled; West of B cooling tower Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 33 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 20 of 66 Sample Point: MW-TMI-14I Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; Aat Hydrogen Staging Tanks Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 34 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 21 of 66 Sample Point: MW-TMI-14D Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; At Hydrogen Staging Tanks Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 35 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 22 of 66 Sample Point: MW-TMI-14S Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; At Hydrogen Staging Tanks Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 36 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 23 of 66 Sample Point: MW-TMI-16I Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: Yes Potential Drinking Water Source: no Other:
Location owner controlled; North of Gate 1 in sallyport Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 37 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 24 of 66 Sample Point: MW-TMI-16D Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: Yes Potential Drinking Water Source: no Other:
Location owner controlled; North of Gate 1 in sallyport Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 38 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 25 of 66 Sample Point: MW-TMI-17I Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; North Parking lot/east of Bldg 48 Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 39 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 26 of 66 Sample Point: MW-TMI-17D Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; North Parking lot/east of Bldg 48 Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 40 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 27 of 66 Sample Point: MW-TMI-18D Date Changed: 10/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; North of East Dike Settling Basin Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 41 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 28 of 66 Sample Point: MW-TMI-19I Date Changed: 10/2/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; South of RML-7 Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 42 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 28 of 66 Sample Point: MW-TMI-19D Date Changed: 10/3/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; South of RML-7 Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 43 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 30 of 66 Sample Point: 48S Date Changed: 10/21/2006 Sample Purge yes Sample Method: Grab Purge/Decon Water Disposal: yes Prior report: No Potential Drinking Water Source: yes Other:
Location owner controlled; Southwest corner of Bldg 48 Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium Q
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 44 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 31 of 66 Sample Point: E1-2 Date Changed: 10/23/2006 Sample Purge yes Sample Method: Grab Purge/Decon Water Disposal: yes Prior report: No Potential Drinking Water Source: yes Other:
Location; Offsite-Visitor Center Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 45 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 32 of 66 Sample Point: EDCB Date Changed: 11/23/2006 Sample Purge yes Sample Method: Grab Purge/Decon Water Disposal: yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; East Dike Settling Basin Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium Q
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma Q
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 46 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 33 of 66 Sample Point: GW-GP-1 Date Changed: 11/9/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; West of Bldg 222 pad Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium Q
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 47 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 34of 66 Sample Point: GW-GP-6 Date Changed: 11/10/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; West of Bldg 222 pad Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium Q
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 48 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 35of 66 Sample Point: GW-GP-8 Date Changed: 11/11/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; West of Bldg 222 pad Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium Q
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 49 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 36 of 66 Sample Point: GW-GP-9 Date Changed: 11/12/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; West of Bldg 222 pad Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium Q
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 50 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 37 of 66 Sample Point: GW-GP-12 Date Changed: 11/13/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; West of U-2 Reactor Building Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium Q
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 51 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 38 of 66 Sample Point: MS-1 Date Changed: 10/7/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: Yes Potential Drinking Water Source: no Other:
Location owner controlled; FO-T-2 off load station Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 52 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 39 of 66 Sample Point: MS-2 Date Changed: 10/8/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location protected area; South of chem cleaning bldg Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 53 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 40 of 66 Sample Point: MS-3 Date Changed: 10/30/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location protected area; East of U-2 Control Bldg Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 54 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 41 of 66 Sample Point: MS-4 Date Changed: 10/9/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location protected area; Southeast corner of protected area Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 55 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 42 of 66 Sample Point: MS-5 Date Changed: 10/10/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location protected area; south end Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 56 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 43 of 66 Sample Point: MS-7 Date Changed: 10/11/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; North of IWTS Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 57 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 44 of 66 Sample Point: MS-8 Date Changed: 10/12/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location protected area; East of U-2 FHB Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 58 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 45 of 66 Sample Point: MS-19 Date Changed: 10/13/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; South of B cooling tower Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 59 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 46 of 66 Sample Point: MS-20 Date Changed: 10/14/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location protected area; West of OESB Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 60 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 47 of 66 Sample Point: MS-21 Date Changed: 10/15/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location protected area; North of diesel building Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 61 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 48 of 66 Sample Point: MS-22 Date Changed: 10/5/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location protected area; West of U-1 Reactor Building Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium Q
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 62 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 49 of 66 Sample Point: MW-1 Date Changed: 10/16/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; East side of site near MW-TMI-2D Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 63 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 50 of 66 Sample Point: MW-2 Date Changed: 10/17/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; At Cooling Tower Desilt Basin Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 64 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 51 of 66 Sample Point: MW-3 Date Changed: 10/18/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; East side of site near MW-TMI-1D Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 65 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 52 of 66 Sample Point: MW-4 Date Changed: 10/19/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; East side of site near MW-3 Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 66 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 53 of 66 Sample Point: N2-1 Date Changed: 10/24/2006 Sample Purge yes Sample Method: Grab Purge/Decon Water Disposal: yes Prior report: No Potential Drinking Water Source: yes Other:
Location ; Offsite-Goldsboro Marina Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 67 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 54 of 66 Sample Point: NW-A Date Changed: 10/25/2006 Sample Purge yes Sample Method: Grab Purge/Decon Water Disposal: yes Prior report: Yes Potential Drinking Water Source: no Other:
Location owner controlled; Southwest of Pretreatment Bldg Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 4000 5000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 68 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 55 of 66 Sample Point: NW-B Date Changed: 10/26/2006 Sample Purge yes Sample Method: Grab Purge/Decon Water Disposal: yes Prior report: Yes Potential Drinking Water Source: no Other:
Location owner controlled; Southwest of Pretreatment Bldg Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 4000 5000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 69 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 56 of 66 Sample Point: NW-C Date Changed: 10/27/2006 Sample Purge yes Sample Method: Grab Purge/Decon Water Disposal: yes Prior report: Yes Potential Drinking Water Source: no Other:
Location owner controlled; Southwest of Pretreatment Bldg Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 4000 5000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 70 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 57 of 66 Sample Point: NW-CW Date Changed: 11/14/2006 Sample Purge yes Sample Method: Grab Purge/Decon Water Disposal: yes Prior report: Yes Potential Drinking Water Source: no Other:
Location owner controlled; Pretreatment Building Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 4000 5000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 71 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 58 of 66 Sample Point: OS-13B Date Changed: 11/1/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location protected area; West of U-2 Reactor Bldg Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 72 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 59 of 66 Sample Point: OS-14 Date Changed: 10/20/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location protected area; West of U-2 Turbine Bldg Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 73 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 60 of 66 Sample Point: OS-18 Date Changed: 10/6/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location owner controlled; East of Bldg 222 pad Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium Q
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 74 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 61 of 66 Sample Point: OSF Date Changed: 10/22/2006 Sample Purge yes Sample Method: Grab Purge/Decon Water Disposal: yes Prior report: No Potential Drinking Water Source: yes Other:
Location owner controlled; West of OSF building Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium Q
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 75 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 62 of 66 Sample Point: RW-1 Date Changed: 11/15/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location protected area; Southeast of Aux Boiler Area Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 76 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 63 of 66 Sample Point: RW-2 Date Changed: 10/4/2006 Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: Yes Potential Drinking Water Source: no Other:
Location protected area; East of Aux Boiler area Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium Q
2000 4000 5000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 77 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 64 of 66 Sample Point: SW-E-1 Date Changed: 8/28/2007 Sample Purge yes Sample Method: Grab Purge/Decon Water Disposal: yes Prior report: No Potential Drinking Water Source: no Other:
Location protected area; East shore of island near MW-TMI-2D Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 78 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 65 of 66 Sample Point: SW-E-2 Date Changed: 8/28/2007 Sample Purge yes Sample Method: Grab Purge/Decon Water Disposal: yes Prior report: No Potential Drinking Water Source: no Other:
Location protected area; East shore of island near Fish ladder catwalk Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 79 of 80 ATTACHMENT 7.2 Sample Point Controlled Data Form Page 66 of 66 Sample Point: SW-E-3 Date Changed: 8/28/2007 Sample Purge yes Sample Method: Grab Purge/Decon Water Disposal: yes Prior report: No Potential Drinking Water Source: no Other:
Location protected area; East shore of island at South Bridge Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)
CY-TM-170-4160 Revision 1 Page 80 of 80 ATTACHMENT 7.3 CONTROLLED RGPP SAMPLE POINT DATA AND STANDARD CONTROL LIMITS Page 1 of 1 Sample Point: ____________ Date Changed: ___________ Sample Purge yes Sample Method: low flow or purge Purge/Decon Water Disposal:
yes Prior report: No Potential Drinking Water Source: no Other:
Location ;
Analytical Requirements Reporting Level (pCi/L)
Laboratory Notification Analyte Internal Outside Report Freq LLD Admin Courtesy External Alert High Tritium S
2000 1600 2000 20000 1200 15000 Sr-90 B
2 APV 2
8 2
6 Gamma A
Ba-140 60 APV 60 200 60 150 Cs-134 15 APV 20 30 20 25 Co-60 15 APV 30 300 30 225 Cs-137 18 APV 20 50 20 40 I-131 15 APV 18 20 18 18 La-140 15 APV 20 200 20 150 Mn-54 15 APV 100 1000 80 750 Nb-95 15 APV 40 400 30 300 Zn-65 30 APV 30 300 30 225 Zr-95 30 APV 30 400 30 150 M monthly Q quarterly S semi-annual T thrice yearly A annual B biennial L level measurement only Analytical Requirements: includes the analytical frequency and required LLD.
Well sampling method - high flow or low flow Threshold for internal action - normally 200 pCi/L tritium for background wells Threshold for external reporting - normally the ODCM reporting value for offsite environmental samples Laboratory alert and high notification values - values that trigger the analytical laboratory to notify the RGPP coordinator in addition to notification levels addressed in CY-AA-170-1000.
Units are picoCuries per liter (pCi/L)