Rancho Seco Final Status.Survey Summary-Report April 2, 2008 Auxiliary Building +0' Rooms 104,105,119-126,128,129,135 and 221 Survey Unit F8130881 Prepared By: 6.b Z
/cJ FSS Enainaef Date:
2 Date:
Reviewed By:
Lead ~S Engineer Approved By:
Date:
DismantlemenfS4uieintendent, Radiological
FINAL STATUS SURVEY
SUMMARY
REPORT Survey Unit:
F8130881, Auxiliary Building +0' Rooms 104,105,119-126,128,129,135 and 221 Survey Unit
Description:
Operating History: The reinforced concrete structure contained the RadWaste processing and supporting systems. The building contained six main elevations. Residual radioactive material was known to be present on all levels of the interior of the building.
Operating records and the HSA document several events with the potential for a release of radioactivity inside this structure. One report documented contamination of the auxiliary building roof. The roof was later replaced.
Site Characterization: Direct measurements were made of each of the interior elevation surfaces as well as the exterior surfaces of the structure. These measurements confirmed the presence of plant-derived radionuclides. Direct measurements on the -47' elevation showed a mean gross activity level of 320,071 dpm/100 cm 2 and a maximum value of 5,720,000 dpm/100 cm2. Direct measurements on the -29' elevation showed a mean gross activity level of 544,756 dpm/100 cm2 and a maximum value of 11,370,000 dpm/l 00 cm2. Direct measurements on the -20' elevation showed a mean gross activity level of 247,831 dpm/100 cm 2 and a maximum value of 10,080,000 dpm/100 cm2. Direct measurements on the grade elevation showed a mean gross activity level of 373,758 dpm/100 cm 2 and a maximum value of 5,800,000 dpm/100 cm2. Direct measurements on the +20' elevation showed a mean gross activity level of 85,408 dpm/100 cm2 and a maximum value of 1,900,000 dpm/1 00 cm 2. Direct measurements on the +40' elevation showed a mean gross activity level of 3,288 dpm/100 cm 2 and a maximum value of 24,781 dpm/100 cm 2. Direct measurements on the building exterior, including the mezzanine roof, showed a mean gross activity level of 1,897 dpm/100 cm 2 and a maximum value of 2,990 dpm/1 00 cm 2. (The roof had been replaced prior to the classification survey.) Based on the classification procedure (DSIP-0020) and levels of gross activity reported, the interior of the auxiliary building was determined to be a Class 1, 2 area and the exterior was a Class 2, 3. The non-controlled areas were Class 3.
HSA Events: HSA Report pg. 63.
Survey Unit Design Information:
The Survey Unit Design Parameters are presented in Table 1 below. The survey unit and measurement locations are depicted on the maps in Attachment 1. Direct measurement locations were randomly determined and 282 m2 were scanned for approximately 6%
coverage. Samples of removable contamination were collected at each direct measurement location. The instrumentation used for the suryey along with the MDC values are listed in Tables 2-1 and 2-2 in Attachment 2.
Page 2 of 8 FSS Summary Report F8130881
Table 1. Survey Unit Design Parameters Survey Design Value Comment Parameter Survey Area:
F813 Survey Unit:
Class:
SU Area (m2):
Evaluator:
DCGL (dpm/100 cm2):
Area Factor:
Design DCGLemc (dpm/100 cm2):
LBGR (dpm/100 cm 2):
Design Sigma (dpm/100 cm2):
Type I Error:
Type II Error:
Predominant Nuclide:
Sample Area (m2):
Scan Area (m2):
Scan Coverage (%):
Sign P:
Calculated Relative Shift:
Relative Shift Used:
N-Value:
Design N-Value + 20%:
Design Min Samples N:
Grid Spacing L:
0881 3
4926 Erin L. Brown 43000 N/A N/A 21500 6935 0.05 0.05 Cs-137 N/A 282 6%
1.645 1.645 0.99865 3.1 3
11 14 14 N/A Auxiliary Building +0' Rooms 104,105,119-126,128,129,135 and 221 Structure Surface LTP Table 5-4 Gross Activity DCGL Class 3 Class 3 Default = 50% DCGL Class 3 Class 3 Uses 3.0 if Relative Shift is
>3 NUREG-1575 Table 5-5 Class 3 Class 3 Page 3 of 8 FSS Summary Report F8130881
Survey Results:
A total of 14 direct measurements were made in F8130881. The results including mean, median, standard deviation and range are shown in Table 2. All direct measurements were less than the DCGL. None of the scan measurements indicated areas of elevated activity. Scan activity ranged from 2029 to 6419 dpm/1 00 cm2, based on a surveyor efficiency of 0.5 and no background subtracted. Samples for removable surface activity were all less than 10% of the DCGL as shown in Table 3. Removable surface activity samples were counted for alpha activity and none was detected at the MDC shown in Table 2-1 of Attachment 2.
Table 2. Direct Measurement Results Measurement ID Gross Activit (dpm/100 cm F8130881-COOOIBD F8I30881-C0002BD F8130881 -CO003BD F8130881-CO004BD F8130881-CO005BD F8130881 -CO006BD F8130881 -CO007BD F8130881-C0008BD F8130881-CO009BD F8130881-Co01o0BD F8130881-Co011BD F8130881-CO012BD F8130881-CO013BD F8130881-CO014BD Mean:
Median:
Standard Deviation:
Range:
1805 1499 1904 1551 1048 1930 1707 1608 1567 1940 1681 1572 1484 1515 1629 1590 233 1048-1940 Page 4 of 8 FSS Summary Report F8130881
Table 3. Removable Surface Activity Results Measurement ID Surface Beta Activity (dpm/100 cm2)
F8130881C0001SM
-0.95 F8130881C0002SM
-2.24 F8130881C0003SM 0.34 F8130881 C0004SM
-3.53 F8130881C0005SM
-4.82 F8130881C0006SM
-3.53 F8130881C0007SM
-0.95 F8130881 C0008SM 2.93 F8130881C0009SM
-2.24 F8130881C0010SM
-2.24 F8130881C0011SM 1.64 F8130881C0012SM
-2.24 F8130881C0013SM 0.34 F8130881 CO014SM 1.64 Mean:
-1.13 Median:
-1.59 Standard Deviation:
2.26 Range:
-4.82 to 2.93 Page 5 of 8 FSS Summary Report F8130881
Survey Unit Data Assessment:
The survey design required 14 direct measurements for the Sign Test. The critical value and the results of the Sign Test are presented in Table 4. The sample mean and median values were less than the DCGL. The sample standard deviation was less than the design standard deviation so no additional samples were required.
Page 6 of 8 FSS Summary Report F8130881
Table 4. Data Assessment Results Survey Results Parameter Value Comment Material Background Used (dpm/100 cm2):
N/A Ambient Background Used (dpm/100 cm 2):
N/A Average Ambient BKG = 0 Actual Direct Measurements (N):
14 Median (dpm/10o cm 2):
1590 Mean (dpm/] 00 cm 2):
1629 Direct Measurement Standard Deviation 233 (dpm/100 cm 2):
Total Standard Deviation (dpm/100 cm 2):
233 Based on samples and backgrounds.
Maximum (dpm/100 cm 2):
1940 Material Type:
N/A Background Subtract Not Applied Sign Test Final N Value:
14 S+ Value:
14 Critical Value:
10 Sufficient Samples Collected:
Yes Maximum Value < DCGL:
Yes Median Value < DCGL:
Yes Mean Value < DCGL:
Yes Maximum Value < DCGLemc:
N/A Class 3 Total Standard Deviation <= Sigma:
Yes Pass the Sign Test?
Yes Reject the Null Hypothesis?
Yes Does the Survey Unit Pass All Criteria?
Yes Page 7 of 8 FSS Summary Report F8130881
Survey Unit Investigations and Results:
No investigations were required for either direct or scan measurements and no investigation results are reported.
ALARA Statement:
As stated in Chapter 4 of the LTP, as long as the residual activity within the survey unit is less than the DCGL (i.e. the survey unit average activity is less than the DCGL and the EMC criterion has been met), the ALARA criterion has been met.
Changes in Initial Survey Unit Assumptions:
The survey unit was designed as a Class 3 structure survey and the sample results are consistent with that classification. The variability of the survey results was less than the characterization data used for survey design. No potential areas of elevated activity were detected
==
Conclusion:==
The FSS of this survey unit was properly designed as a Class 3 survey based on Table 5-4 of the LTP. The required numberof direct measurements was made and the scan coverage met the requirement of Table 5-6 of the LTP. No direct measurements exceeded the DCGL of 43000 dpm/100 cm 2 and none of the removable surface activity measurements exceeded 10% of the DCGL. No investigations were required.
The direct measurement data support rejection of the null hypothesis, providing high confidence that the survey unit satisfied the release criteria and that the data quality objectives were met.
It is concluded that survey unit F8130881 meets the release criteria of 10CFR20.1402.
Page 8 of 8 FSS Summary Report F8130881 Maps April 2, 2008 Survey Unit F8130881
0 t'0 0
C-)
>0 EL 0-0*
.KEY PLANS
- AT EL 1O7n-.
NOTES:
- 1. A~T TWE OF FSS IAAP DEWLOPMENT CASILE TRAM~ P'IPNG. UMTS. AND CONDUIT REMANED W "PLACE. SCAN M&WEMENT LCCA1WNM MY1 NEED TO BE ADIUS1EOW N THE:FEW M0
-~
A000MMOOITE INSITU EOU1PMENT,
- 2. DROP CEILWO HAS SEEN RGW~ED FROM THIS ROOM, PLAN EL 0'-0" REF CLG PLAN EL 19'-2' SACRAMENTO MUNICIPAL UTILff DISTRICT AUXILIARY BUILDING ROOM 104 FLOOR & REFLECTED CEILING PLANS BETA SCAN MEASUREMENT LOCATIONS F8130881-M1 A
A T
0Q 0*
EL.
o--o" 0) r-D 0,0 Lýý-EL 4'-10^
rn EL O-~8 00 w
00 00 ELEV LKG EAST T OL LINE EL 2W-*0
-I D1 U n
EL1G9 DOOR THRESHOLD L04E (CuW RU?.N7D)
E---
-i G
. 41 I0 Iii EL ~-O F
EL 0--0 IO~-i0*____
NT1QES
- 1. AT 71AE O F FSS M41' DEEWLPMENEr CAMLE rRA#S.
PIPNG. LIGHTS. AND CONDUrrREWMkED IN PLACE. SCA~N MEASUREMENT LOCATIONS MAY NEED.T11 BE ADXVS1D IN TH-E FIELD TO ACCOMMO4DATE
.INSITIJ EWLPIAE~r.
- co.su SCRAMIENTO MAUNICIPAL UIJTLITY DISTRICT I
ROOM 104 CORRIDOR WALL ELEVATIONS BETA SCAN MEASUREMENT LOCATIONS F8130881 -M 1 MIETERS
0 EL 20'-G K 7U Ci2 ELEY LKG NORTI-AT EOL LINE 10.6
}
it R
EL 28-6 ELEV 1KG EAS 9'WEST OF COI, UNE S El
'l ELEY LKr3 SOUTH Xr COL LMN 11-7 ELEV LKG EAST AT COL LINE R I-TI 00 00 00-z NOTES:
- 1. AT lIME OF M M0 OEW\\ELCPIEN" CABtE TRAYS.
PIPING. LWGMTS AND CONDUIT REMAINED IN PLACE.
SA IEASSIEE LOCATIONS MAY NEED. TD BE ADJUSTED IN THE FED. TO ACCOMMODATE WN$T1 EOUITMENT.
smu ROOM SMUD' E
RO SACRAMENTO MUNICIPAL UTILITY DISTRICT I R E:
O.D703d AUXIUARY. BUILDING 104 CORRIDOR WALL ELEVATIONS B
.,BETA SCAN MEASUREMENT LOCATIONS F8130.881 -M 1 S*4EI 3 of 32 RE rcR sc ALiE iT TERS YMOND-
0 0
NOTES:
1 -AT 1W E OF FSS MAP DE\\ELDPMENT WIBLE TRAYIS. PIPING. 1J13H13 AND cONDUIr REMAINED IN PLACE SCANP ME4SEI'ENT LOCA11CSMAW NEED 1I)
BE ADJUSTED IN THE FIEW 1TO ACCOMIO(MTE INS~IU E011IP)VEN17.
2-DROP CEILINO HAS BEEN REMOVED FROM TH1S RQOM~
11 EL W-0'-AD fiD K
~KEY PLANS(7
'1~
4E t C2~~) I
[-,
EL
--bD
....~~~ ~~
~ ~ ~
- -f i
t w:s--
(*..
1 2fl)1 (1~'
21_
/
16)_
~
-'--~---~-N-L4~
-I0 00 00 00
! 8'1-9 1W6-9 12" PLAN EL D'-o 12" AUXILuARY BUILDING ROOM 105 FLOOR. PLAN smun BETA SCAN
- SMUDl F813O881-,*
EMEASUREMENT LOCATIONS SCAL UTILIRAENTO MUNIIPAL I"
Fý Bt lwo,wa/J SHLCT 4 of 32 RC Rf','O GND
0 EL- -9'-1' LINE (CLG REMOVED)
H U jOPEN I
[5614
__ _ L*,:*
~ __
-'n *4 2
4.--.-
EL. 7"-2-X" IJL
[1 LKG WEST AT DOOR JAMB LKG EAST AT DOOR JAMBH LKG WEST AT. DOO6R JA SKG LETH AT COL LINE 10,3
ý11 00 00 2!
NQTES:
.i. AT 'TIU E OrF FSS WP DE*LOPEN-CAME TRAYS, PIPING. LCI-S. AND CONIT RE"M ED IN PACE.
SCAN MEASL.REWW LOCAllONS MAY NEED I0 BE,'A&WI*STEO IN THE FMD TO A.;OMmOuTE vIN*-v.U EfoUP)ENT.
SACRA ICENTO IUNKAL UTILITY DISTRICT' ROOM 105 CORRIDOR WALL ELEVATIONS
.,BETA SCAN MEASUREMENT LOCATIONS F8130881 -M 1 SCALE METERS
CD 0
W L-1 EL.....
ZIEZI
- EL 9*-1 SUSPENDED CEIINGO LUNE (CdO R)MVED)
EL 0'-_s.
SV-4' 8--7"
'-I ELEV LKG NORTH AT. O LINE 10.3 ELr-2I--
~I 04
'~1 I
Li OPEN IO J
EL. 0*-r 00 00 LKA WEST AT DOOR JAU LKG EAST JG A
ES AT MiORT8 AT MZtML 1Ki.EAI LKG SOUTH AT DOWP ýW AT COL. LJW 10.3 LKQ WE~
AT DOOR k44W LKG EAST NOTES:
- 1. AT TIME OF M M "P
DENELOPNWT CABLE TRAYS, PIPING. LQI., AND C:ONDUW REMAINED IN PLACE. SCAN MEAMUREMIENT" LOCATIONS MAY NEED "T BE AOJUSTED IN THE FELD TO ACCOMOIDOATE W=~i M OUMENT,
- mn SACRAMENTO MUNICaP, UTILITY DISTRICT ROOM 105 CORRIDOR WALL ELEVATIONS BETA SCAN MEASUREMENT LOCATIONS F8130881 -MA M3,.o3 SHEE-T 6 of 32 1W RA 0
2 SCALE KtTERS
CD 00 0
00 22 o0 LIII EL g'-I*
CEUING UNE OPEN OPEN I
A -
I-I (REMWEE) i EL O-OV ELEV LKG NORTH A V.COL LINE 10.3 lKG
-U-o*-
SH VIErW PLAN VIEw I-i' LKG WESt LKG EAST LKG WEST LKG EAST NOTES:
LKG WEST AT DOOR deI3 LKG UP PLAN VIE~
LKG EAST AT DOOR "B LKG WES LKG EAST SACRAMENTO.:MUNI UTILITY DISTRIT ROOM 105 CORRIDOR WALL ELEVATIONS
.BETA SCAN.
MEASUREMENT LOCATIONS F8130G881 - M 1 HE TERS
0Q 0
0 II 8
OPEN f~i a.
- a. 9~*
L-a.
ELEY LKG SOUTH AT COL UNE 10.6
__F LI
- a. 20-0
].-l*J l
I__L.
J UJI EL. 9'-l CEfLJNO L04E (REMOVED)
EL 0' 00 00 00 ELEV LEK SOUTI AT COL LINE 10.6 NOTES:
1, AT TIME.OF F7 15AP.DEELDvPME" C48LE TRAYS. PPING. LIHIS, ANO CONDOUT REMItEO IN PLACE.
SCN MEASUREMEN LOCATIONS WY NEED TO BE ADJUSTED IN THE FELD TO ACCDIDMODATE INSITU ERUIPM.EN".
ELEY LKG WEST 4-EAST OF cOL uNE H AUXILIARY BUILDING ROOM 105 CORRIDOR WALL ELEVATIONS BETA SCAN MEASUREMENT LOCATIONS F8130881 -M 1 SC ALF PETERS
(D i t
.ELE.
LKG NOT ELM'lB.i...
L I.
01
____-_'_"X I~
E LEY,LKG ESI T EL-
-~~E D'LA II ELEV LKG WEST EL MET 00I NOTES:
REF CLG PLAN AUXIUARY BUILDIN IKG SOUTH Eo
-o" 2
& WAlL VIEWS EL. W-6
SCAN ASURE)AENT LOCATIONS MAY NEED TO BE ADJUSTED IN THE FIELD TO ACCOMMODATE INSITU. EQUPS'MENT.
lSACRAETO MUNICIP UTILITY DSTRICT BETA SCAN MEASUREMENT LOCATION F81.30881 -M.1
0 EL d--
ELEV LKQ NORTH EL 0'--G KEY PLANS I-EL
- EL-!1t ELEV LKG EAUT EL. D'ý-0 L~1EL ELEV 1KG SOUTH i
EL 0*-0 EL B'-6
]EL W-0.
00 00 00
, I 9,-0" NOTES:
REF CIG PLAN EL 8a-6"
- 1. AT~n TiE ogr.-FSS KW DEVELOPMENT uLGHTS,;
OOND.r AND REMOVABLE FURNITURE REMAINED IN :PLACE-SCAN MEASUREMENT LOCATlON M WY NEED TO BE ADJUSTED AN THE FIELD TO SACRUMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING RM 1120 LOWER FLOOR, CEILING
& WALL VIEWS BETA SCAN MEASUREMENT LOCATION F51 30881 -M4 1 F-r: 51 W..
SNET "10 of -32 RC R.iy,{0N0
00 00 00 00
>2
(~N.
\\
ii.',~
K N
- 1 V
~-~
I~J ji
~s;z-9'~
~i2Ž~ ~
\\
FALSE CEILING PLAN VIEW EL 8-0 11
- ,,1
_d. L _"
/_-
_-:J /
ELEV LKG NORTH EL B-85 KEY PLANS Lj 1A ELEV LKQ EAST ELEV LKG SOUT EL W~-6' EL. 8'-r QI T
1.K U
1 L 7 -. ~
~7ZI77flZTLEL.
201-0, 2 EL8-.
R ELEV LKG WEST EL
'-6" U
3L NOTES:
RE" CLG PLAN EL. 1 W-2'
- 1. AT TIME OF FSS WP DEVELOPME3W(t SWRVEY UNIT WAS INACCESSIBLE.
SCAN MEASURE4D'fT LDCAIONS MAY NEED TO BE ADJUSTED IN THE FIELD TD AOCOMMODATE INSTIU EOUIPMElT.
& WALL BETA SCAN MEASUREMENT LOCATION F8130881 -M 1
- L.
.*,*.(3a s
pci..E. 11 of.3" R"
VIEWS
0 20)0 0 ~
~
~
ALJX LOC KEY PLANS I--
00 00 0o PLAN EL 0~m-e
- SCALE T
METERI:
NOTES~
- 1. AT 1UAE Of' MS MAP DBELOJPMENr MOTOR C04IflO0 CENlERS. CABLE TRAYS.
P"'NG,lUGHT.
AND-COND(IT REMLNED
[N,:RAGE.
SCAN WMESRE3JONT L0CAZ1,'
W=YNE O EAJSS IN 7H FIELTO"WACOMWIE 4U EQUIPkMEN.
I
- mu SACRAMENTO MUIC1IPAL.
U11LITY D15TRICT AUXILIARY BUILDING RM 121 FLOOR PLAN 1ETA SCAN, MEASUREMENT LOCATION F81530881-M
- FIE, 5i12=0zsm S HEET 12 o~f 32 Rc A14N
(t~
0
- I I I
I I
PLAN EL 0'-0 171 00 00 00 NOTES:
I,AT 1)UE 0fF-S M4P DEWL1JPWME MOWR COTROL C-NERS. CABLE TRAYS.
PFN. :UG11T, OD:CONDUl REiJNED INPLAGE.
S*C[N4EASUREMiENT OATIONS MiAYNEED TO BE ADJUSTED mNM rfl-n*LD To ACckmmgTE *s EQLqUP&INM.
RM 121 REFLECTED CEIUNG PLAN BETA SCAN MEASUREMENT LOCATION F8130881 -M 1
(T*
0 00 0
00 00 LlL S t It I* P I
I I I
II....
- * *i L
LKGN EN 2--W
- 24^I E,i'W W uoW H0 LXqINIj LOOK<*N0RTH N
LOOKI( NORTH LKG:N EL- 0'-V~
ELEVATION IYCN iI LOOING E&ST T
ELEVATION N
NOTES;
- 1. AT TIME OF MS
'WuýpEVSJO mMOOR coNrRo4. CENTERS CAMLE
- TRAYS, ELECTRIAL BoXmS. PiM UfLM AND AON*UI-REM'ED IN TPlACE.
TCAN mEASUREmENr LOCATPONS W~4Y NEED 713 M ADJUSTED IN THE FlED TO)
MX0UOMOWDTE INSITU EQ.LNPiAEM.
SMUI3 SACRAMENTO MUNIcaPAL UTILfIY DISTRICT ROOM 121 EAST SWITCH GEAR WALL ELEVATIONS BETA SCAN MEASUREMENT LOCATIONS F8130881 -M I SC ALE I
I
0D i
N)
L
'iO S
11 LK -°S I E
-AST
.L O... IN..
lbl~
2111 1 2 t_ 12__
12 WOiN IET OKIG NRrH LOOKINGq WETOUT O..
LOOIG WEST ELEVATION r
EL.. 60-.0" ITI 00 00 00 NOTQES
- 1. AT TIME OF FSS MAP DCvEUOPMEN IJMMOI CONTRXl CENTERS. CMALE TIRAYS.
EI.EaWRIAL BOXES, PiF¶,G UOI{IS1. ANM
.CONOU[r, REMAIED IN PLACE. SC44 MEASUREMENT' LOCATIONS MAY NEED 11)
,EADJUJSTED IN THE: M0E TO ACCOMMODATE INSITU EQUIAPMENT.
- mm SCRAM~ENTO MUNI'CIPAL UIJTLITY DISTRICT AUXILIARY BUILDING ROOM 121 EAST SWITCH GEAR WALL BETA SCAN MEASUREMENT LOCATIONS F8130881-M1 FILF.
- 2EiOOO, SHEET
- 5 of 32 MTRS E LEVATIO NS RC RAYMOrND
("D 11 N
KEY PLANS QQ KOPEN AOPE-4 4 OPEN i
OPi 001 00 00 SCALE NOTES:
- 1. AT "hUE OF FSS kAP DEVELP*M CA
'-E TRAYS. PI1NG,. UGH
-, AND CONDUIT REIiNED H'PIACE.
SCAN.
MEASUREMENT LOCATIONS' I MAY NEED "T BE ADJUSTED IN THE FEWb TO A.
m*O DATE.INSU ouIPmENtI.
REFLECTED CEILING PLAN EL 19'-2' SACRAMENTO IMUNICaPAL UTILITY DISTRICT AUXILIARY BUILDING RMI:4 22 & 123 FLOOR & REFLECT CEILING PLAN BETA SCAN MEASUREMENT LOCATION F81.30881 - M I FILE: BlI O3d T
l of 32 16 6fYMON c
00 0
G I..1
© 1LJ 1
II 2
EL 20-o0 E,.. G"-0O F
LI LKI3N Q
_ ii 1KG N LOIING NORTH.
LO-§9INO EAST
_LO'i(N _SOUqH OING WEST.
,.U~~L t.Ly"QL1U EL EV.
A TI ON ROOUM 12 S....
E L 2 0.--
Li LOOKIN_____~_
LOOKING SOUTH 1LOOKNG WEST DEVELOPED rELVATION ?on iOk 23 00 00 00 4&
SMUR SACRAMENTO *!MUNOI.AL UTILrIT DIkCTIT AUXILIARY BUILDINO ROOM 122 & 123:ZCABLE! SAAFT ELEVATIONS
.1-ETA -SCAN MEASUREMENT -LOCATIONS F8:1.310818 -M 1 sEc
- CA..
SNEET 1 'of 32 RC RW}AOND E
,3 SCALE METERS
N CD
ýý "6 AUIX MiDO aL 0*-w° KEY PLANS
'17 00 00 00 PLAN EL 01-0"
- NOTES,
' VELOPMENMT LOTOR CONTRO. CENTERS. CMXE TRAYS.
PIPING, L, 0MS.
-NMD
- ONDUT REIANWD IN PLACE. SCAN -W MEILRO.dENT WCAlC sNS MAY NEED TO. EIADJUSTED IN THE nEL10 TO ACWW..
E IsTU EQUILqpET.
0 3
4 SCALE METERS AUXILIARY BIUILDING RM 124 FLOOR PLAN BETA SCAN MEASUREMENT LOCATION F8130881 -M I SHEET 18 of 32 RC R.IAYM.O
0 Cd)
/NO~N~
I Ty~ =I/.
s Fu l
PLAN EL 0-0' 00 00 0
1 3
4, NOTIES:_
1.- AT1,i1E OF F~S MA? DBEývtPAn MMOOR CONTROL CENTERS -CABLE
- TRAYS, PPI'NC. LIGf-S. ND'-CON6#T, REIAANED IN, PLACE. SCAN' WkWEASJENT
'LOCATIONS MkYNEED, TO BE ADJUSTED IN il-HIEW TlO.D AUCUMMOPATE INSnr EQUIPWENT.
RM 124 REFLECTEDCEILUNG PLAN BETA SCAN MEASUREMENT LOCATION F8130.881 -MI 5,ki3l*
SNEM. 19 of 32
00 (I) 00 0
00 00 F0 N-/l v \\j VN
-EL 7*-g*-
m m
414 ol
-p II NOTES:
- 1. AT TIME OF F35 MAP DEELDOPIENT MOTOR CONTROL CMENRS, Q'.BE TRAVS, ELECTrw.AL Bon-,~ PIPING. ueHT5m AmD CONDUrREMAINED IN PLACE SRFACE ARE* ESTIWArES DO NOT INCLUOE AM INSITU EQUIPMENT.
SACRANENTO 1UNICIPAL UTILfTY DISTRICT ROOM 124 WEST SWITCH GEAR WALL ELEVATIONS RETA SCAN MEASUREMENT LOCATIONS F8130881 -Ml
On 0
EL ZO'O0-ELEVATION
- EL 20' I C,
11 u
F /
i
/
EL 0'-B' 7
L.-'; G S
I, L1<0W
/,
//lll//
/
/
4/
/..
/.
-TI 00
ý00 LKG S LOOKING WEST ELEVATION~
NOTES:
- 1. AT.iMEOF FMS MAP DEVEM')ENT mwTw 6ONTROL ENTERS, CiAE TRAY%~
EbcrRIQ '.BOXE, FPINO. UGHT3. AND CONDufrREMAINED IN PLAM SURFCE AREA ESTWAB DO NOT INCLLOE ANY INSITU.EQUPUENT.
SMUD SACRAMENTO MUNIIKRAL UTILITY DISTRICT 0
1 2'
3 SCALE METERS ROOM 124 WEST SWITCH
,EAR WALL ELEVATIONS
- BETA SCAN MEASUREMENT' LOCATiONS F8130,881 -Ml FIgE! 313DO0.0od SHEET 21 of 32 RC RAYMOND
0 0
C--
00 00 II 1
Q47) 1.
(H)
-n 19DELAI 4
44>
Ici 4~
.2 PLAN EL 0*--0 jI ELLEYAP.EASI ELLV kK" OUTH
~0_0
-10 10 Jj l EL 0'-0' 25.
E-E3'-9*
YZ-ST
- 0
~
a 3
MET NOTES:
REF CLG PLAN E.L 8e-6
- 1. AT TIME OF FSS W P DEVE.0PME, 'r....
LIG1TS, CONDUIT AND REMWAOV/'&E FRMNIfURE REMAINED IN PLACE.
SCAN MESUJREI.iN LWO' IONS MAY NEED T.
BE ADJUSTED IN THE FIELD TD ACCOMIIODATE INSI'U EQUIPIMET.
- SMUn S
SACRAtdENTO-NUNflIaPAL UTiIMY DISTRCT AUXILIARY BUILDING RM 125 LOWER FLOOR$
CEILING & WALL VIEWS BETA SCAN MEASUREMENT LOCATION FS1 30881 -M 1 Blluimaoc3d SHEET 22 of 32 rc PAYMCNb
0 Vb~II
~ ~
H
-11 I
EL 0"-0" ELE*
LKG-NORTH EL. O-O" KEY PLANS A
0 9 Q
I PLAN EL I 0"-4":
1~
'F r*
.. i.
-I.
Li-(N79 ------* "
~~~2
~-
1!
ELEV LMO EAST EL. (U-0 ELEV LKG SOUTH EL a'-o" f
EL 20*-0" I'
oiO~I!ri 111---'E 00 00 00 ELEV LKG WEST EL 0"-0' SCALE 4E-TEP S NOTES:
REF CLG PLAN
- i. kT T Or m i*
DcvneVELOPUeMa EL. I §'-2 UGM*. CON OUT C
"-E TRAYS.. IVNZ EIPUENT & DU6T WORK REMJNED IN RACE.
SCAN M.ASUREIIENT LOCATIONS MAY NEE_ TO BE ALgJSTE" IN THE RELD TO AGCOMWOA1E NSM AUXILIARY BUILDING 125 UPPER
- FLOOR, CEILING
& WALL BETA SCAN MEASUREMENT LOCATION F8130.881 - MI
0 00 00 00 IT
~
o f
.1
.D 0
1 4'-6 KEY PLANS iLE L1 MGNORT 0
4r 6-4---8r PLAN IRS1 EL 0-0'
~i FL2(BLZ?
I~
Hil Pi) I
_(
Ij)i T I I
4-1 12-L I
-i-14-6 4O 4-T, NOTES:
REF CLG PLAN t A flE o FS MM DEVEL0PMBEJr UG~fS.CODUI AD REMIVABLE FURNITURE REMANED IN R.PLC SCAN WEASUREMIENF LOCATIONS MY NEED TO BE AOJUSTED IN THE FIELD TD ACCOMMODATE INS¶U EQUIPMEn L
ELEV LKG EAST ELEY LKG SOT
<~~~E LI.O-EL0-Ti~~r oK'-1 INI'4 ELEV LKG WEST 1
2 3
SCALE NMiTrp
- mu SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING RM 126 LOWER
- FLOOR, CEILING &
BETA SCAN MEASUREMENT LOCATION F81 30881-M 1 RE! SIMK,.G.0 SHEET 24 of 32 WALL VIEWS:
RE-RAYMOND I
0 E
VE Itt Iit
/
1 FL
- it EL 0*-0-D KEY PLANS ELEV LKG NORTH
.. 0"-0
'-'N I,
PLAN EL 107-4-"-
I -
EJ
~1 L4 H.
11)
[
I=-'
I-it 0
(
____ 1 ELEY LKG SOUTH EL
-0.
I'K LII LI Li EL. 2eO-0 00 00 00 Q
_ _ i NOTES:
REF CLC PLAN
WAC EQUIPMENT& DU£T W REMAINED
-IN PLACE.
SCAN M.EASUREMENT LOCAlONS MIAY NEED TO BE AJW)$TED IN THE nELD TO AcOommooE oqsmi EQUIPMENT.
ELEV LKG WEST EL 0*-0' EL 8*B SCALE RETER3
- mn SACRAMENTO MUNICPAL UTILITY DISTRICT AUXILIARY BUILDING RM 126 UPPER
- FLOOR, CEILINM BETA SCAN.
MEASUREMENT LOCATION F8130881-M.1, Fnt: 2131,rW_0 SNED 25 of -2.
WALL VIEWS RC RYt0GNH
(t~
a i'7i ii It REFLECT. CLG PLAN EL Ir--'
EL 0*-0" KEY PLANS PLAN EL a'-31 Oo 00 00 00 REFLECTED CEILING PLO.
EL Ir-r NOTE EL. 0-"
- 1. AT TME OF FSS MAP DE*_MPIVENT EUEVAT=R EUIPUENt, M
PING UGIS.
AN ONUI4DREMANED IN PLACE.
SOWJ MEASUREUD4T LO.ATIONS MAY NEED TO BE ADJUSTED IN IHE FIELD TM ACCOMMODATE INSITU EOUIPKENT.
0 1
2 S-C ALE H¶ETEP.S SACRAMENTO MUNICIPAL UTILITY DISTRICT ROOM 128 FLOOR & REFLECT CLG PLANS BETA SCAN MEASUREMENT LOCATIONS F8130881-M1
00 0
CI) 00 0000 T1 LKG E 11 a
i ii DEVELOPED ELEVATION
-A65UOT MI:_ KA 81
____ I ELEV 1KG WEST AT 6W W HALI RM 12A ELEV 1KG NORTH NEARt OL 9.3 ELEV LKG OUTH T LVTRSHIFT.
Q.7)
EL: 2V'-03 IL1-
~i~EL.
1 SELEVATION LOOKING WEST
- 1. AT -WE OF F&S MAP DE\\E.nTMENL ELEVATOR E0UPME'rT,.PIPM. U-NTS.
AND CONDUIT REMAINED INPLACE'
$CAN MEkSURE)IDJT LOCATIONS MAY NEED TO BE AIIUSTED' IN 7IHE FIELD TO AcOMOMODATE
- IN:TU EOUIPMENT.
0 2
3 M4E TERS ELEVL G SOUTH ELRý ý69 T
UTILITY DISTRICT IFP K: 513XO3 AUXILIARY BUILDING ROOM 128 WALL ELEVATIONS BETA SCAN MEASUREMENT LOCATIONS F8130881 - M I w*
SHEcT 27 of 32 RC R4Yl¶OND
0D EL 0'-0*
KEY PLANS 7ý REFLECTED CEILING PLA14 EL. W-PLAN EL. 0-01 00 00 00 NOTES:
- 1. AT TIM~E OF~ FSS MP GEWLOPUENT ELEV'ATOR EWLPk4EJr, FpIPIc, LIGHmS AND) CONDUIT REMAINED IN PLACE.
SCAN~
MEASUREII40T LOCATIONS MAY NEED TO BE AWLUSTED IN IME FIELD TO ACCOMODATE INSWTU EUiPMENT.
0 I
CALE METERS RM 129, 221 & 346 FLR & REFLECT, CLG PLANS BETA SCAN MEASUREMENT LOCATIONS F8130881 -M 1
(D 0
0j Eli
______-j If*
F-till
ý2 c
I-.
00 0
c C
r.
00 00 00 NOTES:
- 1. AT INE Or FSs m4p DE*zLDpNr ELEVATOR.EDQJPMI*ENT, PIPIN,_
LU;HM, AND CONDUr RWAWED IN PLACE-
$SCAN MEASUtEMDT"LOCATIMONS IAA' NEED TO. BE AJUSIED IN THE FELD TO AC.OMMODATE WNS!IU EOQLPWE_.-
0 1 S 3
SCMLE 14£TERS AUXILIARY BUILDING 4aUO RM 129, 221 & 346 WALL ELEVATIONS SMUI BETA SCAN MEASUREMENT LOCATIONS UTILFY DISTrICT F8130881 -M 1 F'F. saD.030.
S-f'. 29 of 32 RC RP.YMONtC-
0 C/2 I
-i IIizi-i
.1
_ _I_ _-_l-I--
0 c2l)-
".1
-Q si b:
6
-I 31 Wi
.2 ~
]1 i.--
i t1 I
C 4',
z 0
0
-J zCF hi hi I11 00 00 a?
NOTES;
- 1. AT "I14WE OF FSS k4AKP DEVELOPFEKNT ELEVATOR EQUIPMENT, PIPING. UGHTS.
AND CONDUIT REMAINED IN KACE SCAN IASJN11417* LOCATIMON MAY NEED TO BE ADELUSTED IN 7THE FIELD TO ACC=LMMODWE INSITU EOLRPLENT.
0 1
2 SCALE HETERS
- SMUDRM 12 SACRA1JENTO MIMICIPM._
UTILITY DIS"TRICT I
X(5 AUXILIARY BUILDING 9, 221 & 346 WALL ELEVATIONS
- BETA SCAN MEASUREMENT LOCATIONS F81 30881 - M,,I SHEET 30 of 32 RC RAYMOND
0 c--
128 i
EL 0-"
MXLC KEY PLANS REFLECTED CUILING PLAN EL 5-5"-
PLAN EL O'-0 00 uj 00 00 NOTES:
NB:MEIP4.
SCAN MEASlA~U* T. LOCAIIONS MAY NEED TO BE A&,JSTED IN: THE:IELD TO ACCDUL400ATE INSIT EDIJPUENT.
- 2. DROP CEIUN'G.
AT EL 8'-0" PREVIOUSLY REMOVED.
SMUn SACRAMJENTO MUNICIPAL UTILITh DISTRICT AUXILIARY BUILDING ROOM 135 FLOOR & REFLECT CLO PLANS
... BETA SCAN MEASUREMENT LOCATIONS F81 30881 -M I S:'EEFT 31 of 32 RC RAYM..OND I
2 3S I
0 0'
1~.
0.
EL 20'-0 Ii 1 73 ELEVATION LOOKfING NORTH
.EL8'-3.
EL*'W-8" ELEVATION LOOMING EAST ELEVATION LOOING SOUTH ELEVATION LOOKING WM NOTES:
& HVAC oUCT WOW RDENWED IN PLAOE, SCAN MEASUREMENT LOCATIONS AWY NEED TO BE ADJUSTED IN THE FED iTO ACCOMMOEMTE INSSIrU EQ*.APMEr.
Z. DRLOP..
COUNS AT EL W-O-PREVI(OSLY REVOVED.
.. B-3.....
EL. V'--0 00 0
00 00 DEVELOPED VIEW CLOSET SMUm SACRAM IENTO MUNCIPAL UTILITY DISTRICT AUXILIARY RUILDING ROOM 135 WALL ELEVATIONS BETA SCAN MEASUREMENT LOCATIONS Fg130881-M1 Far_
- 1T:.COI: d SHEET
-12 of 32 0
1 e
a SCALE METEERS RC PR\\Y.O NO-r
OQ 0
0 4l i; i i t 414+1 u
TT M
t+4
- 4-i j
L t~
PL N
IF E
Li 4-
+
i i+-
H 1
ii:i 1 i +44;
ý
_ 41 i 4 f 1;
i i i 111
+"
+ i:
4' elltV
+4 ELUT
-2 H-
_0p miiH+
+
+
H4A:7 t L
T2~_LI xE~
W ALW LEVqIUN R~1261_
~~~~~~
f:4~~
4WLVVnNrI_
AUXILIARY 8UI DI 4 10, 10 11 128128.129 135 221 34 B-fMU 4EA IRC WK k5 ACIVIT WESRN KEY
+
SA4ý(NO~
8 08 M
UIFm QDPLAN.
M Ip~~~~WAIN +
MW_________
__________R t1 00 00 00 O0
CD 0.
ELAN tL V'-0*
00 00 00 0
12 3
4 5
SCALE SMUD S s~cSACRAENTO :MUNIaPAL UTILITY DIWMRICT AUXILIARY BUILDING ROOMS 105, 1.21 &
N24 FLOOR PLAN BETA DIRECT ACTIVITY MEASURMENT LOCATIONS F81 30881-M2 (134 SEL-T 2 of 5 Rc R
0 0
IIK ii 11-4 In
~ii EL 20'--bý CELUNW EL. '--0" k
'~1~'
F---.--
flF ELEVATION LOOKING WEST Room 119 UPPER ELEVATION LOOKING LAST ROOM 120 LOWER
-I J 1
-~
II 1'
II I,
-l
_______________i EL.._2,-..
00 00 00 METERS I.
09 1,
Q"LATVR MUINEW ROOM ELEVATION LOOKING EAST ROOM 127 S
SACRAMENTO ULNIcM..
UTILFIY iSRICT
-AUXILIARY BUILDING ROOMS 119, 120 & 127 WALL ELEVATIONS BETA DIRECT ACTIVITY MEASURMENT LOCATIONS F81 30881 -M2 8l.oo.wd SHEE-3 of 5 RE R6'0MONC.
I
(t~
C I
EL. 0'-e' LOOKING NORTh y-~7 DEVELOPED VIEW ROOM4 1,21 (W~
I
!C C-
.4 __
~ I
+/--
(
ID s~r 111.!
4'-IO
- 1 I
~
.~
I i
4-(11 00 00 METERS nrvmnmrior virwA Dnrtu vi->
LOKIGSOý
- & SMUm SACRAMIENTO MUN4ICIPAL UTILITY DWSRICT FP!:: 8 SY-OC AUXILIARY BUILDING ROOM 121 WALL ELEVATIONS
,B.ETA. DIRECT ACTIVITY MEASURMENT LOCATIONS F81 30881 -M2
.Wd SHEET 4 of 5 rc RAYMFOND
CD uJw0 0
,.j-
~r1 00 00 00 Q
'h-i 1i rrH LIII 0
IEL 0*-O-
- W1GNfiE LOOKINGN NJ WOIN DEVELOPED VIEW ROOM 124 y
(P)
T-EL 26'-01 I
i4~
12
~r1 rn.m Wi KLH Fl F1~
LII F] [.11 EL O'-0 EATalOR STAR 12 REST CONTROLED ROM eo METERSI CONTROLED AOIN ES O
LOOKING NORTH ROOM 105 ELMGTRrAL PANELS SMUn SACRAM~ENTO MUNICIPAL UJTILITY DIS7TRICT AUXILIARY BUILDING ROOMS 105 & 124 WALL ELEVATIOdiS BETA DIRECT ACTIVITY MEASURMENT LOCATIONS
" F81,30881 -M2 iM.OWd SHEr 5 6f 5 RC, AYQIOND FILE: 2
0 C:>
C*r 00 li
! r PLAN7+/-jJik SCALE ME TERS NOTES.
.1..Ar TIME OF F'ý& MVP oEVOPWEW 0N3LE rRY, PIPING LaIGHM AND CONOUWV"NJED IN PLACE. SURFACE AREA ES1WTEs Do NaT INCLuDE ANY INSfl EOUIPMENT.
2..DROP'.CEILING HAS BEEN REjMAED FROM TitS ROOM.
REF CLG PLAN EL. 1G* *mn SACRAM~ENTO MUN~ICIPAL UILITLfY DISTRICT AUXIUARY BUILDING ROOM 104 FLOOR & REFLECTED CEILING PLANS GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F8130881--M3
.l_ý.: !£'1,0;00_03,3 SHEET I of 3.3 Re RIV040NICO
0 00 00 00
.EL 20'.-0_
ill L
I I ODSQ Im CONCRETE ELEY LKG EAST AT COL UNE S AT COL LINE 13 EL 20'-D" EL 9"-1 D
,*SUPENDED CELILNC UNE (C10 RE~4VOED EL 0,-D" 3STEE so STEEL. DOOR.
NOTES:
- 1. AT TIME OF FSS MAP DEVUPMIENT CABLE TRAYS' PIPRS, LUfS. AND O
CONDUIT RDW4INED I PLACE SURFACE AREA ESTWITES DO NOT INCLUDE ANY INSrTU EQUIPMENT.
ROOM 104 CORRIDOR WALL ELEVATIONS GENERAL ARRANGEMENT SURFACE AREA ESTIMATES F81 30881 -M3 SCplE m E --Eýs
cJQ 0
>1<>n if
- 1 EL 20'-U" Al1 CONCRETE COUNG UNE 21 SONEE OPEN 14 SO M CONCRT CONCRETE ELEV mKG EAST T WEST OF COL LINE S ELEY
-KG NORTH AX COL LINE 16.6 4 SQ Mr.,
CONCRETE 14
'I, ELN 8-*-
CEI~dLINGUE
.3 sol STEM_
Fm 22 SQ M.
CONCRETE ELEV LKG SOUTH AT OOL LINE 11.7 ELEY LKG EAST AT COL LINE R 4 SO M CONCRETE AT MO 1INW 11-7 00 00 0O
- 1. AT11UE~OFfS$,WPDEELOPMENT CABLE. RAYM PiPNG*.LIhnS AN{D CONEiTJ REM*INED N PLACE' SURFACE AR ESTAmTESiOO 'NOT INGLUOE Ar INS1V3TU EOUPIAENT'-
AUXIUARY RUILDING SCRAMIENTO MLUNIPIAL UT1Lfl'Y DISTRICT AUXIUARY BUILDING ROOM 104 CORRIDOR WALL ELEVATIONS GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F81 30881 -M3 35 SHE-ET 3 of 233 Rc R4t
(
1 2
3 SCALE METERS FPE,'-R I *IV*
- I
0 IaL 7
'I
.**1I u
I ii r~~~~~~~~----
~-z------2_
-~
A
~----
L
~
J
.- 12.S, m PLAN EL -
!Fi T.
- "*.E. -- -
I..
~T1 PLAN 0 0 E L 0 "--O 0
o0 i.ATE OF MSMA DEEa.
I I
lAUXILIARY BUILDING CABLE TRAYS, PIPING. LEIHTS. AND F
ROOM 105 FLOOR PLAN COMM PE"ED INLACE.
SURFACE GENERAL ARRANGEMENT AREA ESTIMATES DO NOT INCLUDE~
PtWa s
unMCR INSrlU EQUPUE.
a SASURFACE AREA ESTIMATE WiLlY DSTRICT F81 30881 -M3 METERS.
a 0
- 6
- 2. so" m REFLECTEI CoN*-rEt D CEILING PLAN EL 19'-2°
ý4-
ý-11 00 00 00, ELAN EL 01-01 NOTES:
SURFACE
,AR.A ESTlkth."Es DO NOT INCLUDE ANY.
INSJ U E
,.IJENT.
SACRANENTO MUNIaRIPAL UTILITY DISTRICT ROOM 105 REFLECTED CEILING PLAN GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F81 308811 -M3 SCALE HETERS
CD 4--.
p.>
00 00 00 00
/
so m DO SQm
- EEL, CONCRETE
--3 Q M S UNISTRU
=
NI-EL 9'-I' UNE (CLG REI4M)
EL 0-0r C NRETE S STEEL LKG WEST AT DOOR JAM
-0 2 $O M CON CRErE LKG SOUTH AT MOL.
LINE 1U.3
-I Ii
-LJ-6.7SQ M CoNCRE STEEL LKG WEST LKG EAST AT DOOR JAMB AT D00011 d-AU NOTES:
PIPING. LaTn., AND CONDUIT REMAINED IN PLACE.
SURFACE AREA ESTRTIES DO NOT INCLUDE ANY INSI1U EQUIPMENT.
- "-o SARAM1ENTO MUICIRIAL UTILITY DISTRICT AUXILIARY. RUILDING ROOm 15 CORRIDOR WALL ELEVATIONS GENERAL ARRANGEMENT SURFACE' AREA ESTIMATE F81 30881 -M3 K~C3~U~
SHEET 6 of $33,1 t
o 2
I'ETERS
uq CD b
'I) r-n OPEN E-PANELS 113 So m CONCRErE ELEV LKG NORTH AT COL LINE 10.3 J 7 EL ill-J EL. OD-D" 00 U-)
00 00 LKG WEST LKG EAT AT DOOR JAMB AT DOOR.I~AdB
- 1. AT-nE Or FSS EYAEOD*OPMENT CALE TRAYM PiPNG LGWS. AND CONDU~trEME B
AE SURFACE AAESTBMES DO NOr INCLUDE A4 INSTU EQIPMUEN LKG WEST AT DOM JAMB LKG NORTH AT VWSMLE LKG EAST LKG SOUTH.
AT DOOR LAMB Al CDL..LINE 10.3 LKAG WEST LKG EAST AT DOOR 'JAMB
- llsu lwSCRAMNEITO MUNA'ICIPAL UTILITY DISTRICT ROOM 105 CORRIDOR WALL ELEVATIONS GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F8130881 -M3 SCALE KETERS
0 00 00 00o i,i Ii
- 3. i_
M EL 91-1*
CHNc LINE jOPEN OHPE EL 0-0*
- 6. So Mi STEEL DOOR ELEV LKO NORTH AT CO L tE 10.3 LKG UP LKGUP LKG PLAN VIlE PLAN VIEW LKG WEST LKG EAST LKG WEST LKG EAST NOTES:
- 1. AT MMhE OF SS MAP DEVELOPMENT CA4BtE"RYS,.PIRNO, GT.-, ANID CONDUrr ROAim iN K
.s. SRF.AC*E AREA EiMATES 00 NOT I...JDE WINSTU EQUIPMENIT.
I PLAN VIE-LKG WEST LK
,EAS LKG WEST AT Door "Q.B LKG EAST AT DOOR "JaB
- mn SACRAIENTO MUNIS I
UTILITY DIS'TRiCT ROOM 105 CORRIDOR WALL ELEVATIONS GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F81 30881 -M3 C~rr Q f
CtL1' 3
METERS
(.D 0
~1 EL, 20'-0" 4SOM UNISTRUT aL. g'-il" i
CEILING LINE (REMQva) wI
.75 WC M E-PANEL EL 20,-0° -I SUSPENDED (REMOVED)
(!~)
K -,i)
I I K I-IF W
'Ti I
.1 2.5 5s m
STEEL m
(D ELV LIJO SOUTH AT Ot UNE I0.N
,"H
[21 OPEN 0
'I
_H]
~-2 so M, UNIST RUT N8 so m CONCRETE 1.5 50 M CONCRETE a.. zi~t...
41.
00 00 00 aSQ. m L
I Q m L
2.5 SQ U STEEL DOOR GYP BOARD STEEL ODOOR NOTES:
..ATTIME OF FSS lAP DEýnLGPMNTr
¢1.'i TRAYS. PING. ULGHTS, AND CONDUIT REIMNNED IN PLAZE. SURFACE
'AREA--EST)UATES NOT INCUTDE ANY INSIiU ECU IPUENT.
ELEV LKG SOUTH AT COL. LINE 10.0 0
SCALE HETERS 4
ELEV 1KG WEST
______________________IV EASTOF COL. liNE H
- SMUD ROOM SACRAMENTO iAUNICIPAL UTILITY DISTRICT FILE: 31e.OO.03o
.ELEV LKG WEST 4: EAST OF GO[ UNE:H AUXILIARY BUILDING 105 CORRIDOR WALL ELEVATIONS GENERAL ARRANQGEMENT SURFACE AREA ESTIMATE F8130881 'M3 SHE-T 9 of 3S.
RC
.YfMONC,
00 cTJ 00 0
C01 it 1
A li A
EL, '-6 EL 0'-o" MEL DOOR CONCRETE TILIEY LK G :NORTH EL 0'*-0 R I I
i I
PLAN ELo-',o.
F ELrV LKG EAST
- ! 1.'7}
- "T" IW LKG WEST
.CCNcErE
--3 SQ: M1 STEEL DOOR ELEV LKG SOUTH EL Cr-c-S CL 3
S[Trpý C9SON GONORETE CONCRETE SI. DECK STEEL REF CLG PLAN4 EL 8--
LLz ELEV 1\\1,-rF*
EL E -OY
- 1. AT TIE OF FSS kAP DEVELOPMENT UITCNUT A"ND REtDAO1BLE FURNITURE RWAINED IN PLACE."
SUIRACE AREA ESTIMATES DO.NOT INCLUDE ANY INSIU EQLRPMENT.
Ic ROOM I I SACRAMENTO RUNICIPAL UTILITY DISTRICT cit30E0003 AUXILIARY RUILDING 9 FLOOR, CEILING
& WALL VIEWS GENERL ARRANGEMENT SURFACE AREA ESTIMATE F8.1.30881 -M3 SHEET 10 of 33 RC R6YMONE
00 00 00 FIT iPLA
- EL 0`-0" C RS L
CONcRETE STEEL DOOR ELEV LKG NORTI4 E_ 0y-0"
<,3 "T--
16, SO.
M CONCRETE STEEL DOOR i
ELEV LKG EAST
-t.
p 9.-
"\\-j EL. D'--
r JS m
ELEV LKG WEST OONCRIETE I.
,t EL 9 5o.
CONCRETE ELEV LKG SOUTI EL 8--6" EL
',-0" SCALE METERý
- * *------41 2ST DE8 K STQ STL DECK STEEL Q
EL. Wm-0 REF CLG PLAN NOTES:
.EL 8*-"
- 1. AT T""E OF FSS M*P D'.ELDPMENT
- uLIK, CONDUI *0 RDV4iI0LE FURNITURE REMNED IN PLACE.
SURFACE AREA ESTI*MA5 DO NOT INWAUE ANY INSJTU EQUIPMENT.
SACRAMINTO IUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING RM 120 LOWER FLOOR, CEILING GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F81 30881 -M-3 Fr::! si.%Vý.03e SNEUT 11 of 33 WALL VIEWS
00 (ft 0
Ft 00 00 4_
_`_
-'it LJ.D1:
PANELS h~
SOS M H
STLDEC1(
-lii-it STEEL.
1 4 Q ELEV LKG NORT-a.. B' ELEV 1KG *SQUT-CONCRETE ELEV LKG EAST El-11'-8 EL 20-0 LII F
I L
2i;ý:ý4-omcmt-ELEV LKG WEST EL. 8Y-6 SCALE N El ElI NOTES:-
REF
- 1. AT -11ME-OF. FESSMAP DEvELOPMENT UOWH. 0IUMIT.":DRWYO~AB&E FURNITURE REIA'NE IN'PLACE.
SURENE AREA ESThM1ES; DO NOT INMUIDE ANY, INSIUEQUPIPENT.
CLG PLAN EL i'-6" S ACRAMENTO MUN~ICIPAL UTLITY~f D15TRICT I AUXILIARY BUILDING RM 120 UPPER FLOOR, CEIUNG.&
GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F81 30881 -M3 FV SHEET 12 of 33 WALL VIEWS RC RAYM~ONC I.................
0 (It 0
PLAN EL 0'-0" 00 00 00 NOTES:
- 1. AT TWE OF FSS.H DEV*_*OPENT MOTOR CONTROL CNKERS.* CARLE TRXYS, ELECTRCAt BOXC3. PIPMlG LIG81' AND CONDUIT REW'NED IN PLACE.
S*UIJACE AREA I
S 1WJ DO NOT E.
DE ANY INSATU EQUIPMENT.
0 1
2:
3 4.
SCALE RETEPS
ým smuI SACRAMENTO MUNtI*IPAL UTILITY DISTRICT AUXILIARY BUILDING RM 121 FLOOR PLAN GENERAL ARRANGEMENT SURFACE AREA MEASUREMENT F81,30881 "M3 FU..; 3 t3C,G3.0 SHE "I-T i3 of 33
('D La 0
00 00 00 IOI NOT IN SURVEY/I-tJ-i UNISTFWCONCRETE PLAN EL 01-O' C
I 5
3 4
NOTES:
- AND, CDONUFT REMAINED IN PLACEI SURF~ACE AREA ESTIMATES DO NOT INCLLDE ANY INSITUI EWuPkAENT.
I I..............
- mn UJTIL[TY DISTRICT AUXIUARY BUILDING RM 121 REFLECTED CEILING PLAN GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F8130881 -M3
,33o SEE1T 14 of.33 Rc
CD 0
cj 00w 0-0 P;-
L00K1NGNCRIH iN b[ M LUQL :
it LKO N K 5 LOOING EAST
~L~YAUQtA N,
"D L
11(0 SO 1(
L KO E SOM LOOKMN SOUJI LOO1(INC G
r EL za-Dl EL W-O' 11(0 E 11(6 N NOTES:
- 1. AT TIME.OF FSS. k,,P D-'LOPENT' MOTOR~ DONTROL CENtER, CkIKlE TRAMS ELECTRICAL BOXE,. PIPING. UýNITh. ANM CONODfrREMAINED IN,:PLACE SURFAZE AREA ESTIAITES DO NOT INCILUDE ANY INSITU EQU1P*:ENT.
S ROOM 121 SMUD SACRAMENTO MUNICIPAL UTILITY *DISTRICT AUXILIARY' BUILDING EAST SWITCH GEAR WALL GENERAL ARRANGEMENT SURFACE'AREA ESTIMATE F8 130881 - M3 SNEET 15 of 33 o
1 2~
-W ALE PETERS ELEVATIONS RC PbYtIOND
oq 0
cdq Sisi l
E l
!F Fi.--
flG EAS!
L T
LOGKNC'SUTHLGoKINa3WE5ST EL, 20*-0"
,EL. O-D" LKC 1<G L ELEY AION uaLX SOUTH 00 NOTES:
I. AT TIME OF FSS MAP DEVELOPMENT wyroR;f CONTHOL CENTERS, CABLE, IAYS.
ETUICAL I*50X.E PIPIN, UGHTh. AND CoNDWT REMAINED IN PLACE SURFACE ARE ESTIMATES DO NOT INCLUDE ANY
.INSlTU EQUlaPfIENHT 1w SACRAMENTO MUNICIPAL UTILITY DISTRICT AUXILIARY BUILDING ROOM 121 EAST SWITCH GEAR WALL GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F81 30881 -M3 VILE. *'*l'ooo(13 SHEET 16 of 33 SC ALE METERS ELEVATIONS RC F6iYMO N
0 coo 00 00 00
- L) 6-A)
N a SQ -
EL 0'-0" I
i i
OPEN OPEN_
H!
NOTES:
REFLECTED CEILING PLAN EL 19'-2' SQ RU SCALE METERO I
&IIYII IA~V ~IIII flhI~J~
- 1. AT III& OF* FSS mw DWL(PMlENT CN~tE TRAYS, PIPING, U*HT, AND ooNDirir RE#-NE..IN PLACE. SURFACE AREA ESTIMATES DO NOT CW-OE ANY INSM EOUPNENT.
RMU 1:22 & 123 FLOOR & REFLECT CEILING PLAN SMUD GENERAL ARRANGEMENT lw SURFACE AREA ESTIMATE SACRAMENTO MUNIVCIPALF830 1-3 UTILrTY DWTRICT F8150881 -M3 FIE!
',V.0,a.
SHEC-T 17 of 33 Rc RC7fl'oND
(J) 0 00 00 00 w
I EL. 20-0ý)
tL o*-o'
ýCONCRETE LKQ N LIMINO N(
NOTES:
- 1. Ak TIW~ OF FSS WP DM~LOPMAENT C*aEIIETRAYS, PIPINCý UOnHTS, ANO COONDUITRtELWIHED IN PLACE. 9MRACE AR.EASTMATES DO NOT INCLDE ANY NSITU ECILIFMENT.
0 SEL 20'-0" EL 0'-0° DEVELOPED ELEVATION. ROOM, 1,23
- SMUm ROOM 1 SACRAMENTO MUNICIPA UTILITY DISTRICT TIlf S311,00.030 AUXIUARY BUILDING 22 & 123 CABLE SHAFT: ELEVATIONS GENE9L ARRANGEMENT.
SURFACE AREA ESTIMATE F81.30881 -M3 S-EET 18 of 33
!4C RAYMOND 0
1 2
SCALE
(J) 0
-1 CONCRETE PLAN EL. 0--0" 00 0
I000 NOTES:
- 1. AT
.... T*ME'OF FSS AP. DEvnOPt.OT MOTOR CONTRR L,CNITERS, ABLE TR,'M5, ELGTRWhAL BOXES PRING. LIGHTS, AND CONDUIT RER..NED IN.PLACE. SURFACE AREA E*nmUE Do NOT 1 w-woE ANY ItsUU Eoup**
SCA*LE M4ETERS AUXILIARY BUILDING RM 124 FLOOR PLAN GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F81 30881 -M3 SHCET 19 of 33.
Rc RzYtMOtN
00 NOT IN/'
OR-PLAN EL 01--o" 00 00 SCALE' NOQTES
- 11.
AT TWM OF FMS IMP DnEItLCPM09 MOTOR CONROL CENTERS. CABLE TRAWS.
ELEETRALh SOXES PtRNG. LIGHTS. AND OCINDUrr REWNED~ IN PLA'CE, SURFACE AREA EsliMATES DO NOT INCLUDE ANY IHS(TU EOUPMENT.
S SACRAM4ENTO MUNRICIPAL UTIILITY DISTRICT AUXILIARY PUILDING RM 124 REFLECTED CEIUNG PLAN GENERAL ARRANGEMENT SURFACE AREA ESTIMATE FS 130881 - M3 SkL-ET 20 ý o $33 Rc WlfiQND,
0 00 00 22 K
LIZ EL. 20"-r
-u
'-wI 11(0W E
L1( N, LOOKING EAST EL 20'-0 i-I 0
z El-O'-.0 STL. DOOR "ON", EE SuLONG ST LOOK.
O N
E LKG E LOOINGSOUHI 1KG. W ELEVATION N",I TFR-1, AT TIME OF F~SSAP OE'%ELOPIENr MOTOR. CDONTRa CE.NTEKS QABLE, TRAYS 1
ELECTRICAL BOXMS "PIPING.- UGHTS. AND CONWlT REMAINED IN RLACE- 'SURFACE AREA ESTIMTES: DO NOT-I NCLUD)E ANK INSI1UEQUFIIENT.
- SUDROOM 1,24 SACRAMENTO MUN4PMIAL UTILITY DSTRICT AUXIUARY RUILDING WEST SWITCH GEAR WALL GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F81 30881 -M43 SHEET 21 'f
.3.
ELEVATIONS 0
1
.2 SCAL-L KIETERS Z
0 EL. 20-0' ZO OK Eli izzi nj m
U LXos LK u
E Ji ll-*
H~
LKG E I CONCRETE RK LKO S EL. 0'-0 LKO W LKO N 1---
-11LOOKINOO m 7H
LOOKING SOUTH LOOMON WEST ELEMITON!*
I-DOOR EL. 20ý-0 S 0ým CONCME EL. O'-0 U(G, W 001 00 00 LKG S
- UXIKIN, WMS ELEVATION NOTES:
- 1. AT TiME OF SS W
DoE,*OPENr mOTOR wwrRoL cENTEn, CABLE TRAYS,
'ElETa
.BOXES, F1PING. U*HMT..AND CONL REMAINED IN PLAE SURFACE A
"A ESTIWAES DO NOT INCLUDE MY INSITU EQUIPI4Efr.
ROOM 124 WEST SWITCH GEAR WALL ELEVATIONS GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F81 308811-M3 SCALE W VER-s
CD i 2l5 r12.1 EL. QG-a' KEY PLANS ELEV LKG NORTH EL 0'-O" IL (7\\H
- 1.
1so m REM L
.5S
.a u ELEV LKG EAST.
EL Q*-O" 9ý sq.
CONCK-M ELEY LKG SOUTH EL. W-o' EL. Er-sl 00 00 00 NOTES:
REFCLG PLAN
REMOWILE FtPETURE REMiNED IN PLACEL SURF~a AREA ESTIMATES DO NOT INCLUDE-ANY INStrU EWIPMENT.
1 wS m ISTEE 125 LOWER
- FLOOR, CEILING" I
WALL GENERAL ARRANGEMENT.
SURFACE AREA ESTIMATE F8130881 -M3
0'k.)
0
.-..I 00 00 0>
00 18 so w, NOTES:
EWIP'dENT & DUCT WORK REMAEIf IN PLACE.
SUJRFACE AREA ESTIMATES, DO NOT INCLUDAE ANY IN:SITU EQUIPMAENT,
.5 SQ M STEEL i so m STEEL ELEV LKG NORTI E. 0'-0" P.H Y
ELEV LKG EAST ELEY LK*
EL. O'-*O" EL.
22 50 M 1-CONCRETE EL. 2O-O
~ri ii I
i ~ ~
~
~ ~ ~ ~ ~ ~ ~ E g-e, G SOUTH oe-0" EL. 10o ELEY LKG WEST EL* O'-O0 0
1
- 2.
3 SCALE METERP 3 So M UNISTRUT REF CLG PLAN EL. IW-2" SACRAMENTO MLaAIPL UTUIrrY DISTRICT AUXILIARY BUILDING RM 125 UPPER
- FLOOR, CEILING GENERAL ARRANGEMENT SURFACE. AREA ESTIMATE F8130881 -M3 fIE_: Rl*c, l*,
SHEET 24 of 33 WALL VIEWS RC Rbt.YThO ND
0 CONCRETE MMEE DOR J NOTES:
- 1. AT.TTIE OF FSS IAMP DEELOPUENT L.HTs.,
ONDUIrr, PIPING &
WVA5LE FURNITURE REMAINED IN PLACE.
SURFACE ARE.A ESUATES DO NOT INCLUDE ANY NSnU EQtP.mNT.
ELIEV LKG NORTH EL 0"'0"
.19 sa M CONCRETE CONCREI' I.4Il ELEV LKG EAST EL ELEV LKG SOUTH EL 0'-O' 17 SC0 M CONCRETE EL. V'-6 El. f0,--o IT0 00 00 00 ELEV LKG WEST SCALE 3IT.
METERý EL: ra AUXILIARY BUILDING 125 LOWER
- FLOOR, CEILING
& WALL VII GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F81 30881 -M3 31",XXwX3A SHEET 25 of 33 RC P-AYt,
0 1-.<
IIii
'Ii II Ii II II II ii D!.i 17 SQ* MU CONCRETE NOTES:
- 1. AT, TIMIE OF FSS IAAP DEVELOPMENT SURVEY UIWM WAS WOMBLEIt LJK4MS.2 O3NOUIr, CABLE TR&YS. H@.C EMAPMENT & DUCT WOW( ARE ASSUMED TO REMAIN IN PtAGE.
SURFACE AREA ESTIVATES 0O NOT INCLUDE ANY NSITU EOUPMENT.
L-1 ELEY LKG NORTH I.
.0F22 soki CONCRETE L39 SQ MI.
CONCRETE PLAN EL. I 0-4-t ELEV LKG EAST EL W ELEV LKG SOUTH EL- 0'-0*
11 K-25 SQ L4 STEEL
_I EL.20*-0 EL 8-6 rE 00 C) 00
?-0 ELEY LKG WEST EL 0*-*0 SCALE REF CLG PLAN EL 19'-27
. AUXILIARY BUILDING iM 125 UPPER
- FLOR, CEILuNG
- SMUD GENERAL ARRANGEMENT SURFACEI AREA ESTIMATE RAIENTO MSICPALT F81030881 -M3.
Fr-Eý 3C0Q.CZ*
SNEET 26 of 33 WALL VIEWS Rc PX CON0
0Q on O
W BECK REFLECT. CLG PLAN
-EL
'-a 7 SQ M STEEL DECK IrJ 00 00 00 9
PLAN REFLECTED CEILING PLAN EL. 0*-0" EL 1Ti"-"
NOTES:
t, AT ME,OF FSSIMAP O*k P
LOTW. CONOUrT AND ELEVATOR EQUP)MEN'T REM ED IN. PLACE.
SURFACE AREA ESTWIATES*DO NOT INCLUME ANY.
A NSITU IEEAPE*'I.
- mu WW SCRAMIENTO MUNf'ICIRAL UTILITY DISRICT AUXILIARY BUILDING ROOM 128 FLOOR 'PLAN GENERAL ARRANGEMENT.
SURFACE AREA ESTIMATE F8130881 -M3 SHEET 27 of 33.
SCALE METERS OP OA'hirm~r' a
RC RAM40NC I
ON 0
w 00 00 00J LKOEF OPEN EL G'-O-ELUa'-0" j __
j, i) Sj
<E LKG E i
E
[s N
5 squmDEVELOPED ELEVATION ABU 5M SQA4 GYP WALL BOARD LOO L~~~~E
-_0'°
... L _
F, I
7, srEo EL. 8*-.3 EL.,
ELEVATION LOOKING WEST AT COL K NOTES:
.PMED9f UONh.
Q'~ur $4IDELEVATOR EQUPMEN REMANED IN PC.E.-
SURFACE AREA ESTMAES DO NOT INCLUDE 'wMf INSrtU EoUPMENT.
- KG !AST BOARD AUXILIARY BUILDING ROOM 12.8 WALL ELEVATIONS GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F81 30881 -M3 SHEET 28 of 33 o
1 KCALE METERS
COIN 0
od EL OP-(
N KEY PLANS 6 SQ MA PLAN
-ONRETE EL O~0 AT EL 6 SQ M-CONCREfE REFLECTED CEILING PLAN EL 59' -.
00 00 00 NOTES:
1..AT TIME 'OF FSSAP K
DEVE,.DPA"ENT ULIHT5. cONUrr AND.E.'AVTR EQUPMENT REMIENE IN.PLýCE.
SUIRFACE AREA ESTIMATES 0..*T INCLUDE AN INSITU EQUIPMENT.
GENERAL.ARRANGEMENT SURFACE ',AREA ESTIMATE F81:30881 -M I
-TC ALE HETERS
ONQ 00 0
>j
. ( aDl-I-_---------
rl
~1 0
ru 64 c-C2)-
Ii I
I,1 tow It 00 00 00 NOTES:.
I. AT 11k4E OF FSS IMAP DELDaNUEN UGM C01'iorr AND ELEVATOR EQIUPMENT RE*INED IN PLACE.
SUR*tFNE"AREA ESTWTES DO NOT INCLUDE ANY IN5fDU EIMPIENT.
S un RM 1 2 SACRAMIENTO MUNIOIPAL UTILI'f DI'TRICT FI
,*ILE 3o,
boe AUXILIARY BUILDING
_9, 221 & 346 WALL ELEVATIONS GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F8130881 - M3 SI-IecE 30 of 33 PC *,*'*ONC SCALE
,}-ES ERS;
-O 0
iii M
- i
]
I-Idj' -
I-I..
z P
21 ii
7--F-'
c 4j.
III 2
w 08 I.1 00 0
00 NOTES:
1: AT TUE OF FSS.kAP DEWO*DPENT LIMT CONDUT r AND CLEVATOR EQU1PIAENT REKAED IN PLACE.
SIJRFAE.AA ESTMTIES DO>
NOT INCLUDE AIY :INSITU EDUIPMENT.
URM 12 SACRAM*ENTO MUNICIPAL UTILITY DISTRICT FLER
-i3E'DXe AUXILIARY BUILDING 9, 221 & 346 WALL ELEVATIONS GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F81 30881 -M3 SI-EET 31 of 33 RC RAYMOND 93 1
2 SCALE METERS
0D EL' 0'-6 KEY PLAN 1 squr uJNmmurU 6,:wm 7 so m CONCRETE PLAN EL W-6 REFLECTED CEILING PLAN.
EL S9'-*,i 00 00 00 NTA~ES
- 1. AT TIME OF FSS. MAP OEVAEU)PMENT PIPNG, CMVM,1AT& WAC DJCVMKKJ REMAINED INJ PLACE. SURFACE' AREA.
ESTINATES DOI NOT NJCLUDE ANY 9-MT EQUIPMENr.
I. WOO~ COLING AT $'--V PREV(OUSLY REMWI4OE MUD SACRAMENTO IAUNnPFIC UTuLITY DISTRICT -.
C; 3
SCALE 14ETERS ROOM 135 FLOOR & REFLECT CLG PLANS GENERAL ARRANGEMENT SURFACE AREA ESTIMATE F81 30881-M3 51M0,5, SSETf 32 of 33 RC FcRYi
0 I,-
IEQ~~
cERAUic -L LDOOKING EAST il EL. 2Vo-*
5 SQ m
ýCERAW.g TILE ELEYAWtN LOOKING NOM~
i I
K
- 10. SQ CERAMIC TILE ELEVATION LOOKING WEST 4 SQ m -
STh D0OM ELEATIC LOOK(ING SOUTH 4-SQ U CQNWRETE 2 TSQM. -
5m oooiR EL O-O~
O10 00 0000 NOTES:
I:- AT 'n ME OF MS MAP OEWILINfi4ENT Pn~NG. COtNtirr & HVAC DUCTWORK R19EDA~ IN RACE& SURFACE AREA.
E5TIMATES,00 NUT INCLUDE ANYr HWU~j EQUIPMENT.
,Z DR6P CEILING AT
-0PREVIOUSLY REMMEa ctOSaNE WRtO SMUm SACRAMENTO k4L*iCP/AL UTILITY DISTRICT AUXILIARY BUILDING ROOM 1,!35 WALL ELEVATIONS
,GENERIAL ARRANGEMENT SURFACE AREA ESTIMATE F81,30881 -M3 SHEET 33 of C13 SCALE RETERS Rc RtaxwioN
ýur!
Instrumentation April 2, 2008 Survey Unit F8130881
Table 2-1. Survey Unit Instrumentation Instrument Detector MDC Static MDC Scan Model; Serial No.
Model; Serial No.
(dpm/100 cm 2 )
(dpm/100 cm')
M2350; 193715 43-68B; 148630 433 1033 M2350; 180738 43-68/5B; 148942 433 1033
.M2350; 142499 43-37; 148502 N/A 616 ISOCS 1983920 N/A 1210 (Cs 137)
ISOCS 1983920 N/A 1190 (Co6u)
Tennelec; 0401171 N/A 5.9 dpm a, N/A 11.7 dpm Table 2-2. Investigation Criteria and DCGL Value Parameter (dpm/100 cm 2)
Investigation Criteria - Direct 21500 Investigation Criteria - Scan 43000 DCGLw 43000 DCGLEMC N/A Att. 2 Instrumentation
-:Page 2 of 2 F8130881 Investigation April 2, 2008 Survey Unit F8130881 (none required)
Data Assessment April 2, 2008 Survey Unit F8130881
F8130881 Gross Activity Sample Results Quantile Plot DCGL = 43000 dpml/I 00cm 2
.2,500 2,000
-+
4&
S
~
~1590 1,500 500>
00 0
20 40 60 80 100 Percentile w
Direct Measurements (dpml1 00cm2) -
median 75th Percentile 50th Percentile 00 20
CD w-i o
A*
F8130881 Gross Activity Sample Results Scatter Plot DCGL = 43000 dpmflOOcm 2 A
0
-4 w
C) r0 0D Co CD
-4 2500 E2000 C,
00C1500-E 500-0 0
0 0
0 0
0 0
0 0~
o N 0
0 0
0-0>
0 0
04 0
0 in i1 in in i
in in in in in in in in in o
0 0
0 0
0 U
U U
o 0
0 0
0 0
0 0
0 0
0 0
0 0
o 0
0 0
- 0) 0 0
- 0) 0 0
- 0) 0J 0
0 Measurement Locations
, o Gross Activity -
Average -
"+3StDev" -
"-3StDev 2328 1629 1931
IV w
UP (D
-4, 0
tzý Cn En CD En Cn
ýI CD a
F81,30881 Gross Activity Frequency Plot DCGL = 43000 dpm/1 00cm2 5-C 4
3 2
1 -
0 00 00
.00 Bins - Upper End Value (dpm/1 00cm2)