May 21, 2008 Mr. Charles G. Pardee Chief Nuclear Officer and Senior Vice President Exelon Generation Company, LLC Chief Nuclear Officer AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555
SUBJECT:
CLINTON POWER STATION, UNIT NO. 1; DRESDEN NUCLEAR POWER STATION, UNITS 2 AND 3; LASALLE COUNTY STATION, UNITS 1 AND 2; LIMERICK GENERATING STATION, UNITS 1 AND 2; OYSTER CREEK NUCLEAR GENERATING STATION; PEACH BOTTOM ATOMIC POWER STATION, UNITS 2, AND 3; AND QUAD CITIES NUCLEAR POWER STATION, UNITS 1 AND 2 - CORRECTION OF SAFETY EVALUATION SUPPORTING RELIEF REQUEST AUTHORIZATION TO USE BOILING-WATER REACTOR VESSEL AND INTERNALS PROJECT GUIDELINES IN LIEU OF SPECIFIC AMERICAN SOCIETY OF MECHANICAL ENGINEERS CODE REQUIREMENTS (TAC NOS. MD5352 THRU MD5363)
Dear Mr. Pardee,
On April 30, 2008, the Nuclear Regulatory Commission (NRC) staff issued a letter authorizing relief from the requirements of Title 10 of the Code of Federal Regulations, Section 50.55a, for the subject plants in response to your letter dated April 19, 2007, as supplemented by letters dated October 5, 2007, January 8, and April 4, 2008.
Subsequent to its issuance, Mr. Tom Loomis of your staff identified a typographical error on page 2 of Attachment 1, wherein the marking for Note 2 (i.e., (2)) was omitted from the table cell containing the BWRVIP Exam Scope for the Shroud Support Weld (Weld H9). The NRC staff has verified that the note was included in the application for relief and was considered by the NRC staff as part of its review, and that omission from the April 30, 2008, letter, was a typographical error. The error has been corrected in the attached page 2 of Attachment 1; please use it to replace corresponding page in the April 30, 2008, safety evaluation (SE).
These corrections do not change the conclusion reached in the SE. We regret any inconvenience these errors may have caused.
If you have any questions, please contact me at (301) 415-1055.
Sincerely,
/RA/
Christopher Gratton, Sr. Project Manager Plant Licensing Branch III-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-461, 50-237, 50-249, 50-373, 50-374, 50-352, 50-353, 50-219, 50-277, 50-278, 50-254 and 50-265
Enclosure:
As stated cc w/encl: See next page
If you have any questions, please contact me at (301) 415-1055.
Sincerely,
/RA/
Christopher Gratton, Sr. Project Manager Plant Licensing Branch III-2 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-461, 50-237, 50-249, 50-373, 50-374, 50-352, 50-353, 50-219, 50-277, 50-278, 50-254 and 50-265
Enclosure:
As stated cc w/encl: See next page DISTRIBUTION:
PUBLIC LPL3-2 R/F RidsNrrDorlLpl3-2 RidsNrrLAEWhitt LPL1-2 R/F RidsNrrDorlLpl1-2 RidsNrrLAABaxter RidsNrrPMCGratton RidsOgcRp RidsRgn3MailCenter RidsRgn1MailCenter RidsNrrDorlDpr RidsNrrPMPBamford RidsNrrPMSSands RidsNrrPMJWiebe RidsNrrPMJHughey RidsNrrPMEMiller RidsNrrPMMDavid RidsAcrsAcnw&mMailCenter RidsNrrDciCvib GCheruvenki, NRR ADAMS Accession Number: ML081370390 OFFICE LPL3-2/PM LPL3-2/LA DCI/CVIB/BC LPL3-2/BC LPL3-2/BC NAME CGratton EWhitt (T.Harris for)
MMitchell HChernoff RGibbs DATE 05/19/08 05/16/08 05/19/08 05/19/08 05/21/08 OFFICIAL RECORD COPY
Clinton Power Station, Unit No. 1 cc:
Corporate Distribution Exelon Generation Company, LLC Via e-mail Clinton Distribution Exelon Generation Company, LLC Via e-mail Clinton Resident Inspector U.S. Nuclear Regulatory Commission Via e-mail Illinois Emergency Management Agency Division of Disaster Assistance &
Preparedness Via e-mail J. W. Blattner, Project Manager Sargent & Lundy Engineers Via e-mail Chairman of DeWitt County c/o County Clerks Office Via e-mail
Dresden Nuclear Power Station, Units 2 and 3 cc:
Corporate Distribution Exelon Generation Company, LLC Via e-mail Dresden Distribution Exelon Generation Company, LLC Via e-mail Dresden Resident Inspector U.S. Nuclear Regulatory Commission Via e-mail Chairman Grundy County Board Via e-mail Illinois Emergency Management Agency Division of Disaster Assistance &
Preparedness Via e-mail
LaSalle County Station, Units 1 and 2 cc:
Corporate Distribution Exelon Generation Company, LLC Via e-mail LaSalle Distribution Exelon Generation Company, LLC Via e-mail LaSalle Resident Inspector U.S. Nuclear Regulatory Commission Via e-mail Phillip P. Steptoe, Esquire Sidley and Austin Via e-mail Assistant Attorney General Chicago, IL 60603 Via e-mail Chairman LaSalle County Board Via e-mail Attorney General Via e-mail Chairman Illinois Commerce Commission Via e-mail Illinois Emergency Management Agency Division of Disaster Assistance &
Preparedness Via e-mail Robert Cushing, Chief, Public Utilities Division Illinois Attorney General's Office 100 W. Randolph Street Chicago, IL 60601
Limerick Generating Station, Unit Nos. 1 and 2 cc:
Christopher Mudrick Site Vice President Limerick Generating Station Exelon Generation Company, LLC 3146 Sanatoga Road Sanatoga, PA 19464 Ed Callan, Plant Manager Limerick Generating Station Exelon Generation Company, LLC 3146 Santoga Road Sanatoga, PA 19464 Manager Regulatory Assurance - Limerick Generating Station Exelon Generation Company, LLC 3146 Sanatoga Road Sanatoga, PA 19464 Senior Vice President - Mid-Atlantic Operations Exelon Generation Company, LLC 200 Exelon Way, KSA 3-N Kennett Square, PA 19348 Chief Operating Officer-Exelon Nuclear Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Senior Vice President -Operations Support Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Vice President Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Director, Licensing and Regulatory Affairs Exelon Generation Company, LLC Correspondence Control P.O. Box 160 Kennett Square, PA 19348 Manager Licensing Exelon Generation Company, LLC Correspondence Control P.O. Box 160 Kennett Square, PA 19348 Correspondence Control Desk Exelon Generation Company, LLC 200 Exelon Way, KSA 1-N-1 Kennett Square, PA 19348 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Senior Resident Inspector U.S. Nuclear Regulatory Commission Limerick Generating Station P.O. Box 596 Pottstown, PA 19464 Library U.S. Nuclear Regulatory Commission Region I 475 Allendale Road King of Prussia, PA 19406 Director, Bureau of Radiation Protection Pennsylvania Dept. of Environmental Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469 Chairman Board of Supervisors of Limerick Township 646 West Ridge Pike Linfield, PA 19468 Dr. Judith Johnsrud National Energy Committee Sierra Club 433 Orlando Avenue State College, PA 16803
Limerick Generating Station, Unit Nos. 1 and 2 J. Bradley Fewell, Esquire Associate General Counsel Exelon Generation Company, LLC 4300 Winfield Road Kennett Square, PA 19348 Mr. Charles G. Pardee Chief Nuclear Officer and Senior Vice President Exelon Generation Company, LLC 200 Exelon Way Kennett Square, PA 19348
Oyster Creek Nuclear Generating Station Site Vice President - Oyster Creek Nuclear Generating Station AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 Senior Vice President-Operations Support AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Kathryn M. Sutton, Esquire Morgan, Lewis, & Bockius LLP 1111 Pennsylvania Avenue, NW Washington, DC 20004 Patrick Mulligan, Chief Bureau of Nuclear Engineering New Jersey Department of Environmental Protection 25 Arctic Parkway Ewing, NJ 08638 Vice President - Licensing and Regulatory Affairs AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415 Mayor of Lacey Township 818 West Lacey Road Forked River, NJ 08731 Manager Regulatory Assurance Oyster Creek Generating Station AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 Senior Resident Inspector U.S. Nuclear Regulatory Commission P.O. Box 445 Forked River, NJ 08731 Director - Licensing and Regulatory Affairs AmerGen Energy Company, LLC Correspondence Control P.O. Box 160 Kennett Square, PA 19348 Manager Licensing - Oyster Creek Exelon Generation Company, LLC Correspondence Control P.O. Box 160 Kennett Square, PA 19348 Ron Bellamy, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406-1415 Correspondence Control Desk AmerGen Energy Company, LLC 200 Exelon Way, KSA 1-NB1 Kennett Square, PA 19348 Plant Manager Oyster Creek Nuclear Generating Station AmerGen Energy Company, LLC P.O. Box 388 Forked River, NJ 08731 Associate General Counsel Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Chief Operating Officer (COO)
AmerGen Energy Company, LLC 4300 Winfield Road Warrenville, IL 60555 Senior Vice President - Mid-Atlantic Operations AmerGen Energy Company, LLC 200 Exelon Way, KSA 3-N Kennett Square, PA 19348
Peach Bottom Atomic Power Station, Unit Nos. 2 and 3 cc:
Site Vice President Peach Bottom Atomic Power Station Exelon Generation Company, LLC 1848 Lay Road Delta, PA 17314 Plant Manager Peach Bottom Atomic Power Station Exelon Generation Company, LLC 1848 Lay Road Delta, PA 17314 Regulatory Assurance Manager Peach Bottom Atomic Power Station Exelon Generation Company, LLC 1848 Lay Road Delta, PA 17314 Chief Operating Officer (COO)
Exelon Nuclear Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555 Resident Inspector U.S. Nuclear Regulatory Commission Peach Bottom Atomic Power Station P.O. Box 399 Delta, PA 17314 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. Roland Fletcher Department of Environment Radiological Health Program 2400 Broening Highway Baltimore, MD 21224 Correspondence Control Desk Exelon Generation Company, LLC 200 Exelon Way, KSA 1N1 Kennett Square, PA 19348 Director, Bureau of Radiation Protection Pennsylvania Department of Environmental Protection Rachel Carson State Office Building P.O. Box 8469 Harrisburg, PA 17105-8469 Board of Supervisors Peach Bottom Township 545 Broad Street Ext.
Delta, PA 17314-9203 Mr. Richard McLean Power Plant and Environmental Review Division Department of Natural Resources B-3, Tawes State Office Building Annapolis, MD 21401 Dr. Judith Johnsrud National Energy Committee Sierra Club 433 Orlando Avenue State College, PA 16803 Manager-Financial Control & Co-Owner Affairs Public Service Electric and Gas Company P.O. Box 236 Hancocks Bridge, NJ 08038-0236 Manager Licensing-Peach Bottom Atomic Power Station Exelon Generation Company, LLC P.O. Box 160 Kennett Square, PA 19348 Vice President - Licensing and Regulatory Affairs Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555
Peach Bottom Atomic Power Station, Unit Nos. 2 and 3 cc:
Senior Vice President-Mid-Atlantic Operations Exelon Generation Company, LLC 200 Exelon Way, KSA 3-N Kennett Square, PA 19348 Senior Vice President - Operations Support Exelon Generation Company, LLC 200 Exelon Way, KSA 3-N Kennett Square, PA 19348 Director - Licensing and Regulatory Affairs Exelon Generation Company LLC Correspondence Control P.O. Box 160 Kennett Square, PA 19348 Associate General Counsel Exelon Generation Company, LLC 4300 Winfield Road Warrenville, IL 60555
Quad Cities Nuclear Power Station, Units 1 and 2 cc:
Corporate Distribution Exelon Generation Company, LLC Via e-mail Quad Cities Distribution Exelon Generation Company, LLC Via e-mail Quad Cities Resident Inspector U.S. Nuclear Regulatory Commission Via e-mail David C. Tubbs MidAmerican Energy Company Via e-mail Managing Senior Attorney MidAmerican Energy Company Via e-mail Chairman Rock Island County Board of Supervisors Via e-mail Illinois Emergency Management Agency Division of Disaster Assistance & Preparedness Via e-mail
ATTACHMENT 1 (cont.)
ASME Item No.
Table IWB-2500-1 Component ASME Exam Scope ASME Exam ASME Frequency Authorized Alternative BWRVIP Exam Scope BWRVIP Exam BWRVIP Frequency Interior Attachments Beyond Beltline - Steam Dryer Hold-down Brackets BWRVIP-48-A Table 3-2 Bracket Attachment VT-3 Each 10-year Interval Guide Rod Brackets BWRVIP-48-A Table 3-2 Bracket Attachment VT-3 Each 10-year Interval Steam Dryer Support Brackets BWRVIP-48-A Table 3-2 Bracket Attachment EVT-1 Each 10-year Interval Feedwater Sparger Brackets BWRVIP-48-A Table 3-2 Bracket Attachment EVT-1 Each 10-year Interval Core Spray Piping Brackets BWRVIP-48-A Table 3-2 Bracket Attachment EVT-1 Every 4 Refueling Cycles Upper and Middle Surveillance Specimen Holder Brackets BWRVIP-48-A Table 3-2 Bracket Attachment VT-3 Each 10-year Interval Shroud Support (Weld H9) including gussets where applicable BWRVIP-38, 3.1.3.2 Figures 3-2 and 3-5 Weld H9(2)
EVT-1 or UT Maximum of 6 years for one sided EVT-1, Maximum of 10 years for UT B13.30 Weld H12 Shroud Support Legs Accessible Welds Rarely Accessible VT-3 Each 10-year Interval BWRVIP-38, 3.2.3 Weld H12 Per BWRVIP-38 NRC SER (7-24-2000) inspect with appropriate method (4)
When accessible Revised by letter dated