BSEP 08-0047, Cycle 17 Core Operating Limits Report

From kanterella
(Redirected from ML081200893)
Jump to navigation Jump to search
Cycle 17 Core Operating Limits Report
ML081200893
Person / Time
Site: Brunswick Duke Energy icon.png
Issue date: 04/22/2008
From: Ivey R
Progress Energy Carolinas
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
BSEP 08-0047
Download: ML081200893 (50)


Text

Progress Energy APR Z 2 2008 SERIAL: BSEP 08-0047 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555-0001

Subject:

Brunswick Steam Electric Plant, Unit No. 1 Docket No. 50-325/License No. DPR-71 Unit 1 Cycle 17 Core Operating Limits Report Ladies and Gentlemen:

Enclosed is a copy of the Core Operating Limits Report (COLR) for Brunswick Steam Electric Plant (BSEP), Unit 1, Cycle 17 operation. Carolina Power & Light Company, now doing business as Progress Energy Carolinas, Inc., is providing the enclosed COLR in accordance with BSEP, Unit 1 Technical Specification 5.6.5.d. The enclosed revision of the COLR supersedes the report previously submitted by letter dated May 15, 2007 (i.e.,

ADAMS Accession Number ML071410450).

No regulatory commitmients are contained in this letter. Please refer any questions regarding this submittal to Mr. Gene Atkinson, Supervisor - Licensing/Regulatory Programs (Acting), at (910) 457-2056.

Sincerely, Randy C. Ivey Manager - Support Services Brunswick Steam Electric Plant Progress Energy Carolinas, Inc.

Brunswick Nuclear Plant PO Box 10429 Southport, NC 28461 Ao

Document Control Desk BSEP 08-0047 / Page 2 WRM/wrm

Enclosure:

Brunswick Unit 1, Cycle 17 Core Operating Limits Report April 2008 cc (with enclosure):

U. S. Nuclear Regulatory Commission, Region II ATTN: Mr. Victor M. McCree, Regional Administrator (Acting)

Sam Nunn Atlanta Federal Center 61 Forsyth Street, SW, Suite 23T85 Atlanta, GA 30303-8931 U. S. Nuclear Regulatory Commission ATTN: Mr. Joseph D. Austin, NRC Senior Resident Inspector 8470 River Road Southport, NC 28461-8869 U. S. Nuclear Regulatory Commission (Electronic Copy Only)

ATTN: Mrs. Farideh E. Saba (Mail Stop OWFN 8G9A) 11555 Rockville Pike Rockville, MD 20852-2738 Chair - North Carolina Utilities Commission P.O. Box 29510 Raleigh, NC 27626-0510

BSEP 08-0047 Enclosure

.i.

Brunswick Unit 1, Cycle 17 Core Operating Limits Report April 2008

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design Calc. No. 1B21-1287 Page 1, Revision 0 BRUNSWICK UNIT 1, CYCLE 17 CORE OPERATING LIMITS REPORT April 2008 Prepared By:

Verified By:

Approved By:

Westmorelando, Gregory 2008.04.18 1"7i:00:-13 -04Q00 Greg Westmoreland BWR Fuel Engineering - Lead Engineer Pribyl, David 2008.04.18,17:03:46 -04'00' David Pribyl BWR Fuel Engineering - Senior Engineer Blom, Michael Supervisor Approval 2008.04.19 08:28: 7 -04'00' Michael Blom BWR Fuel Engineering - Supervisor

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design Calc. No. 1B21-1287 Page 2, Revision 0 LIST OF EFFECTIVE PAGES Page(s) 1-47 Revision 0

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1 B21-1287 B1C17 Core Operating Limits Report Page 3, Revision 0 TABLE OF CONTENTS Subject Page C o v e r..................................................................................................................................................

1 List of Effective Pages........................................................................................................................

2 Table of Contents...............................................................................................................................

3 L is t o f T a b le s......................................................................................................................................

4 L ist o f F ig u re s......................................................................................................................................

5 Nomenclature....................................................................................................................................

6 Introduction and Summary..........................................................................................................

8 APLHGR Limits.................................................................................................................... 9 MCPR Limits.......................................................................................................................................

9 LHGR Lim its.....................................................................................................................................

10 PBDA Setpoints................................................................................................................................

11 RBM Setpoints..................................................................................................................................

12 Equipment Out-of-Service.................................................................................................................

12 Single Loop Operation......................................................................................................................

12 Inoperable Main Turbine Bypass System......................................................................................

13 Feedwater Temperature Reduction...............................................................................................

13 References.......................................................................................................................................

14

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1B21-1287 B1C17 Core Operating Limits Report Page 4, Revision 0 I

CAUTION References to COLIR Figures or Tables should be made using titles only; Figure and Table numbers Imay change from cycle to cycle.

LIST OF TABLES Table Title Paqe Table 1:

R BM System Setpoints...............................................................................................

15 Table 2:

RBM O perability Requirem ents................................................................................

16 Table 3:

P B D A S etpoints......................................................

............................................ 17 Table 4:

Exposure Basis for Brunswick Unit 1 Cycle 17 Transient Analysis.............................

18 Table 5:

Power-Dependent MCPRp Lim its...............................................................................

19 NSS Insertion Times - BOC to < NEOC Table 6:

Power-Dependent MCPRP Lim its...............................................................................

20 TSSS Insertion Times - BOC to < NEOC Table 7:

Power-Dependent MCPRP Lim its...............................................................................

21 NSS Insertion Times - BOC to < EOCLB Table 8:

Power-Dependent MCPRp Lim its...............................................................................

22 TSSS Insertion Times - BOC to'< EOCLB Table 9:

Power-Dependent M CPRp Lim its...............................................................................

23 NSS Insertion Times - BOC to < MCE (FFTR/Coastdown)

Table 10: Power-Dependent MCPRp Limits.......................................

........... 24 TSSS Insertion Times - BOC to < MCE (FFTR/Coastdown)

Table 11: Flow-Dependent M CPRf Lim its..................................................................................

25 Table 12: ATRIUM-10 Steady State LHGRss Limits...................................................................

26 Table 13: G E14 Steady-State LHG Rss Lim its.................................................................................

27 Table 14: ATRIUM-10 Power-Dependent LHGRFACp Multipliers..............................................

28 NSS Insertion Times - BOC to < EOCLB Table 15: ATRIUM-10 Power-Dependent LHGRFACp Multipliers..............................................

29 TSSS Insertion Times - BOC to < EOCLB Table 16: ATRIUM-10 Power-Dependent LHGRFACp Multipliers..............................................

30 NSS Insertion Times - BOC to < MCE (FFTR/Coastdown)

Table 17: ATRIUM-10 Power-Dependent LHGRFACp Multipliers..............................................

31 TSSS Insertion Times - BOC to < MCE (FFTR/Coastdown)

Table 18: ATRIUM-10 Flow-Dependent LHGRFACf Multipliers.................................................

32 Table 19: ATRIUM-10 Steady-State MAPLHGRss Limits..........................................................

33

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1B21-1287 B1C17 Core Operating Limits Report Page 5, Revision 0 Table 20: GE14 Steady-State MAPLHGRss Limits..................................................................

34 GEi4-P 1ODNAB416-17GZ-10OT-150-T-2496 (only)

Table 21: GE14 Steady-State MAPLHGRss Limits....................................................................

35 GE14-P1ODNAB413-16GZ-10OT-150-T-2660 (only)

Table 22: GE14 Steady-State MAPLHGRss Limits....................................................................

36 GE 14-P1ODNAB429-18GZ-10OT-150-T-2661 (only)

Table 23: GE14 Steady-State MAPLHGRss Limits....................................................................

37 GE14-P1ODNAB437-12G6.0-100T-150-T-2662 (only)

Table 24: GE14 Steady-State MAPLHGRss Limits................................

38 GE14-P1ODNAB407-16GZ-10OT-150-T-2853 (only)

Table 25: GE14 Steady-State MAPLHGRss Limits...................................................................

39 GE14-P1ODNAB425-18GZ-100T-150-T-2854 (only)

Table 26: GE14 Power-Dependent MAPFACp Multipliers..........................................................

40 Table 27: GE14 Flow-Dependent MAPFACf Multipliers.............................................................

41 LIST OF FIGURES Fiqure Title or Description Page Figure 1:

Stability O ption III Power/Flow M ap............................................................................

42 OPRM Operable, Two Loop Operation, 2923 MWt Figure 2:

Stability O ption III Power/Flow M ap............................................................................

43 OPRM Inoperable, Two Loop Operation, 2923 MWt Figure 3:

Stability O ption III Power/Flow M ap................................................................................

44 OPRM Operable, Single Loop Operation, 2923 MWt Figure 4:

Stability O ption III Power/Flow M ap............................................................................

45 OPRM Inoperable, Single Loop Operation, 2923 MWt Figure 5:

Stability O ption III Power/Flow Map............................................................................

46 OPRM Operable, FWTR, 2923 MWt Figure 6:

Stability Option III Power/Flow Map....................................

47 OPRM Inoperable, FWTR, 2923 MWt

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design Calc. No. 1B21-1287 Page 6, Revision 0 APLHGR APRM ARTS BOC BSP BWROG CAVEX COLR CRWE DIVOM EFPD EOC EOCLB EOFP EOOS F

FHOOS FFTR FWTR HCOM ICF NOMENCLATURE Average Planar Linear Heat Generation Rate Average Power Range Monitor (Subsystem)

APRM/RBM Technical Specification Beginning of Cycle Backup Stability Protection BWR Owners Group Core Average Exposure Core Operating Limits Report Control Rod Withdrawal Error Delta CPR Over Initial MCPR Versus Oscillation Magnitude Effective Full Power Day End of Cycle End of Cycle Licensing Basis End of Full Power Equipment Out of Service Flow (Total Core)

Feedwater Heater Out of Service Final Feedwater Temperature Reduction Feedwater Temperature Reduction Hot Channel Oscillation Magnitude Increased Core Flow LCO LHGR LHGRss LHGRFAC LHGRFACf LHGRFACp LPRM MAPLHGR MAPLHGRss MAPFAC MAPFACf MAPFACp MAPFACSLO MCE MCPR MCPRf MCPRp Limiting Condition of Operation Linear Heat Generation Rate Steady-State Maximum Linear Heat Generation Rate Linear Heat Generation Rate Factor Flow-Dependent Linear Heat Generation Rate Factor Power-Dependent Linear Heat Generation Rate Factor Local Power Range Monitor (Subsystem)

Maximum Average Planar Linear Heat Generation Rate Steady-State Maximum Average Planar Linear Heat Generation Rate Maximum Average Planar Linear Heat Generation Rate Factor Flow-Dependent Maximum Average Planar Linear Heat Generation Rate Factor Power-Dependent Maximum Average Planar Linear Heat Generation Rate Factor Maximum Average Planar Linear Heat Generation Rate Factor when in SLO Maximum Core Exposure Minimum Critical Power Ratio Flow-Dependent Minimum Critical Power Ratio Power-Dependent Minimum Critical Power Ratio

Progress. Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design Calc. No. 1B21-1287 Page 7, Revision 0 NOMENCLATURE (continued)

MELLL MEOD MSIVOOS NEOC NFWT NSS OLMCPR OPRM OOS P

PBDA PRNM RBM RFWT RTP SLMCPR SLO SRV SRVOOS STP TBV TBVINS TBVOOS TIP TLO TS TSSS Maximum Extended Load Line Limit -

Maximum Extended Operating Domain Main Steam Isolation Valve Out of Service Near End of Cycle Nominal Feedwater Temperature Nominal SCRAM Speed Operating Limit Minimum Critical Power Ratio Oscillation Power Range Monitor Out of Service Power (Total Core Thermal)

Period Based Detection Algorithm Power Range Neutron Monitoring (System)

Rod Block Monitor (Subsystem)

Reduced Feedwater Temperature Rated Thermal Power Safety Limit Minimum Critical Power Ratio Single Loop Operation Safety Relief Valve Safety Relief Valve Out of Service Simulated Thermal Power Turbine Bypass Valve Turbine Bypass Valves In Service Turbine Bypass Valves Out of Service (all bypass valves OOS)

Traversing Incore Probe Two Loop Operation Technical Specification Technical Specification SCRAM Speed

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design CaIc. No. 1B21-1287 Page 8, Revision 0 I CAUTION References to COLR Figures or Tables should be made using titles only; Figure and Table numbers may change from cycle to cycle.

I Introduction and Summary The Brunswick Unit 1, Cycle 17 Core Operating Limits Report (COLR) provides values for the core

.operation limits and setpoints required by Technical Specifications (TS) 5.6.5.a.

Item

.Requiremient TS Table 3.3.1.1-1 Average Power Range Monitors-OPRM Upscale.

Function 2f TS 3.3.1.1 LCO Condition I Alternate method to detect and suppress thermal-hydraulic instability oscillations.

TS Table 3.3.2.1-1 Rod Block Monitor-Upscale and Operability Requirements Function 1 TS 3.2.1 Average Planar Linear Heat Generation Rate (APLHGR).

TS 3.2.2 Minimum Critical Power Ratio (MCPR).

TS 3.2.3 Linear Heat Generation Rate (LHGR).

TS LCO 3.4.1 APLHGR, MCPR and LHGR limits for SLO.

TS-LCO 3.7.6 APLHGR, MCPR and LHGR limits for an inoperable Main Turbine Bypass System.

Core Operating Limits required to be documented in COLR:

  • PBDA setpoints
  • RBM allowable values and power range setpoints TS 5.6.5.b Analytical methods approved by the NRC for determining core operating limits.

STS 5.6.5.c Core Operating Limits shall be determined such that all applicable limits of the safety analysis are met.

TS 5.6.5.d The COLR shall be provided upon issuance for each cycle to the NRC.

The core operating limits and setpoints presented in this COLR have been determined using NRC approved methodologies in accordance with TS 5.6.5.b and are established such that all applicable limits of the plant safety analysis are met in accordance with TS 5.6.5.c.

In addition to the TS required core operating limits and setpoints, this COLR also includes maps showing the allowable power/flow operating range including the Option III stability ranges.

The generation of this COLR is documented in Reference 1 and is based on analysis results documented in References 2, 3, 4 and 5.

Progress Energy Nuclear Fuels. Mgmt. and Safety Analysis Design Calc. No. 1 B21-1287 B1C17 Core Operating Limits Report Page 9, Revision 0 APLHGR Limits Steady-state MAPLHGRss limits are provided for ATRIUM-10 (Table 19) and GE14 (Tables 20 -25).

These steady-state MAPLHGRss limits must be modified as follows:

GE14 MAPLHGR limits have a core power and core flow dependency. GE14 power-dependent MAPFACP multipliers (Table 26) and flow-dependent MAPFACf multipliers'(Table 27) must be used to modify the steady-state MAPLHGRss limits (Tables 20 - 25) for off-rated conditions.

ATRIUM-10 MAPLHGR limits do not have a power or flow dependency. However, in order to be consistent with the determination of GE14 MAPLHGR limits, power-dependent MAPFACP multipliers and flow-dependent MAPFACf multipliers with a constant value of 1.0 under all conditions have been assigned to ATRIUM-10.

GE14 power-dependent MAPFACp multipliers are dependent on EOOS as indicated in Table 26. See COLR section titled "Equipment Out of Service" for a list of analyzed EOOS conditions. Care should be used when selecting the appropriate multiplier set.

The applied MAPLHGR limit is dependent on the number of recirculation loops in operation.

The steady-state MAPLHGR limit must be modified by a MAPFACSLO multiplier when in SLO.

-MAPFACSLo has a fuel design dependency as shown below.

The applied TLO and SLO MAPLHGR limits are determined as follows:

MAPLHGR LimitTLO = MAPLHGRss x (MAPFACp, MAPFACf, 1.06)in MAPLHGR LimitSLO = MAPLHGRss x (MAPFACp, MAPFACf, MAP"FACSLO)min where MAPFACSLO

= 0.85 for ATRIUM-10 fuel

= 0.80 for GE14 fuel Linear interpolation should be used to determine intermediate values between the values listed in the tables. Some of the limits tables show two breakpoints at 26.0%P and 50.0%P. IF performing a hand calculation of a limit AND the power is exactly on the breakpoint (i.e. 26.0 or 50.0), THEN select the most restrictive limit associated with the breakpoint.

Hand calculated results may not match a POWERPLEX calculation since normal monitoring of the APLHGR limits with POWERPLEX uses the complete set of lattices for each applicable fuel type provided in Reference 5.

MCPR Limits The MCPR limits presented in Tables 5 through 11 are based on the TLO SLMCPR listed in Technical Specification 2.1.1.2.

MCPR limits have a core power and core flow dependency. Power-dependent MCPRP limits are presented in Tables 5 through 10 while flow-dependent MCPRf limits are 'presented in Table 11.

Power-dependent MCPRp limits are dependent on CAVEX, SCRAM insertion speed, EOOS, fuel design, number of operating recirculation loops (i.e., TLO or SLO) and core thermal power.

Values for the CAVEX breakpoints are provided in Table 4. See COLR section titled "Equipment Out of Service" for a list of analyzed EOOS conditions. Care should be used when

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1B21-1287 B1C17 Core Operating Limits Report Page 10, Revision 0 selecting the appropriate limits set.

The MCPR limits are established such that they bound all pressurization and non-pressurization events.

The power-dependent MCPRP limits (Tables 5-10) must be adjusted by an adder of 0.01 when in SLO.

The applied TLO and SLO MCPR limits are determined as follows:

MCPR LimitTLO = (MCPRp, MCPRf)max MCPR LimitSLO = (MCPRP + 0.01, MCPRf)max Linear interpolation should be used to determine intermediate values between the values listed in the tables. Some of the limits tables show two breakpoints at 26.0%P and 50.0%P. IF performing a hand calculation of a limit AND the power is exactly on the breakpoint (i.e. 26.0 or 50.0), THEN select the most restrictive limit associated with the breakpoint.

LHGR Limits Steady-state LHGRss limits are provided for ATRIUM-10 (Table 12) and GE14 (Tables 13). These steady-state LHGRss limits must be modified as follows:

ATRIUM-10 LHGR limits have a core power and core flow dependency. ATRIUM-10 power-dependent LHGRFACp multipliers (Tables 14-17) and flow-dependent LHGRFACf multipliers (Table 18) must be used to modify the steady-state LHGRss limits (Table 12) for off-rated conditions.

ATRIUM-10 power-dependent LHGRFACp multipliers are dependent on CAVEX, SCRAM insertion speed, EOOS, fuel design and core thermal power. Values for the CAVEX breakpoints are provided in Table 4. See COLR section titled "Equipment Out of Service" for a list of analyzed EOOS conditions. Care should be used when selecting the appropriate multiplier set.

" The original licensing basis for GE14 LHGR limits did not include a core power and core flow dependency. However, in order to be consistent with the determination of ATRIUM-10 LHGR limits, power-dependent LHGRFACP multipliers and flow-dependent LHGRFACf multipliers with a constant value of 1.0 under all conditions have been assigned to GE14.

GE14 LHGR limits are effectively monitored by GE14 APLHGR limits in accordance with the NRC approved methodology described in Reference 12.

The applied LHGR limit is not dependent on the number of operating recirculation loops. No adjustment to the LHGR limit is necessary for SLO.

The applied LHGR limit is determined as follows:

LHGR Limit = LHGRss x (LHGRFACp, LHGRFACf)min Linear interpolation should be used to determine intermediate values between the values listed in the tables. Some of the limits tables show two breakpoints at 26.0%P and 50.0%P. IF performing a hand calculation of a limit AND the power is exactly on the breakpoint (i.e. 26.0 or 50.0), THEN select the most restrictive limit associated with the breakpoint.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1B21-1287 B1C17 Core Operating Limits Report Page 11, Revision 0 PBDA Setpoints Brunswick Unit 1 has implemented BWROG Long Term Stability Solution Option III (OPRM) with the methodology described in Reference 6. Plant specific analysis incorporating the Option III hardware is described in Reference 13. Reload validation has been performed in accordance with Reference 7.

The analysis was performed at 100%P assuming a two pump trip (2PT) and at 45%F assuming steady-state (SS) conditions at the highest rod line power (60.5%). The PBDA setpoints are set such that either the least limiting MCPRp limit or the least limiting MCPRf limit will provide adequate protection against violation of the SLMCPR during a postulated reactor instability. Based on the MCPR limits presented in Tables 5 through 11, the required Amplitude Trip Setpoint (1.12) is set by the least limiting 100%P MCPRP limit (1.35) which has an associated Confirmation Count Setpoint (14). The PBDA setpoints shown in Table 3 are valid for any feedwater temperature.

Evaluations by General Electric (GE) have shown that the generic DIVOM curves specified in Reference 7 may not be conservative for current plant operating conditions for plants which have implemented Stability Option Ill. To address this issue, AREVA has performed calculations for the relative change in CPR as a function of the calculated HCOM. These calculations were performed with the RAMONA5-FA code. This code is a coupled neutronic-thermal-hydraulic three-dimensional transient model for the purpose of determining the relationship between the relative change in ACPR and the HCOM on a plant specific basis. This method was developed consistent with the recommendations of the BWROG in Reference 8. The generation of the plant-specific DIVOM data with this model is consistent with the BWROG resolution of this nonconservatism as provided in Reference 9.

In cases where the OPRM system is declared inoperable, Backup Stability Protection (BSP) in accordance with Reference 10 is provided. Analyses have been performed to support operation with nominal feedwater temperature conditions and reduced feedwater temperature conditions (FHOOS and FFTR).

The power/flow maps (Figures 1-6) were developed based on Reference 4 to facilitate operation under Stability Option Ill as implemented by Function 2.f of Table 3.3.1.1-1 and LCO Condition I of Technical Specification 3.3.1.1. All maps illustrate the region of the power/flow map above 25% RTP and below 60% drive flow (correlated to core flow) where the system is required to be enabled. The generation of these maps is documented in Reference 2.

The maps supporting an operable OPRM (Figures 1, 3 and 5) show a Scram Avoidance Region, which is not a licensing requirement but is an operator aid to illustrate where the OPRM system may generate a scram to avoid an instability event. Note that the STP scram and rod block limits are defined in Technical Specifications, the Technical Requirements Manual, and Plant procedures, and are included in the COLR as an operator aid rather than a licensing requirement.

Figures 3 and 4 implement the corrective action for AR-217345217345which restricts reactor power to no more than 50% RTP when in SLO with OPRM operable or inoperable. This operator aid is intended to mitigate a spurious OPRM trip signal which could result from APRM noise while operating at high power levels.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1B21-1287 B1C17 Core Operating Limits Report Page 12, Revision 0 RBM Setpoints The nominal trip setpoints and allowable values of the control rod withdrawal block instrumentation are presented in Table 1 and were determined to be consistent with the bases of the ARTS program (Reference 11). These setpoints will ensure the power-dependent MCPR limits will provide adequate protection against violation of the SLMCPR during a postulated CRWE event. Reference 3 revised these setpoints to reflect changes associated with the installation of the NUMAC PRNM system. RBM operability requirements, consistent with Notes (a) through (e) of Technical Specification Table 3.3.2.1-1, are provided in Table 2.

Equipment Out-of-Service Brunswick Unit 1, Cycle 17 is analyzed for the following operating conditions with applicable MCPR, APLHGR and LHGR limits.

Base Case Operation SLO TBVOOS FHOOS Combined TBVOOS and FHOOS Base Case Operation as well as the above-listed EOOS assumes the following items OOS:

Any 1 inoperable SRV 1 inoperable TBV Up to 40% of the TIP channels OOS Up to 50% of the LPRMs OOS Please note that during FFTR/Coastdown, FHOOS is included in Base Case Operation and TBVOOS.

Single Loop Operation Brunswick Unit 1, Cycle 17 may operate in SLO over the entire MEOD range with applicable MCPR, APLHGR and LHGR limits. The following must be considered when operating in SLO:

SLO is not permitted with FHOOS.

SLO is not permitted with TBVOOS.

SLO is not permitted with MSIVOOS.

Various indicators on the Power/Flow Maps are provided not as operating limits but rather as a convenience for the operators. The purposes for some of these indicators are as follows:

The SLO Entry Rod Line is shown on the TLO maps to avoid regions of instability in the event of a pump trip.

A maximum core flow line is shown on the SLO maps to avoid vibration problems.

APRM STP Scram and Rod Block nominal trip setpoint limits are shown at the estimated core flow corresponding to the actual drive flow-based setpoints to indicate where the Operator may encounter these setpoints (See LCO 3.3.1.1, Reactor Protection System Instrumentation

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1B21-1287 B1C17 Core Operating Limits Report Page 13, Revision 0 Function 2.b: Average Power Range Monitors Simulated Thermal Power - High Allowable Value).

Figures 3 and 4 implement the corrective action for AR-217345217345which restricts reactor power to no more than 50% RTP when in SLO with OPRM operable or inoperable. This operator aid is intended to mitigate a spurious OPRM trip signal which could result from APRM noise while operating at high power levels.

Inoperable Main Turbine Bypass System Brunswick Unit 1, Cycle 17 may operate with an inoperable Main Turbine Bypass System over the entire MEOD range and cycle with applicable APLHGR, MCPR and LHGR limits as specified in the COLR. An operable Main Turbine Bypass System with only one inoperable bypass valve was assumed in the development of the Base Case Operation limits. Base Case Operation is synonymous with TBVINS. The following must be considered when operating with TBVOOS:

Two or more inoperable bypass valves renders the entire Main Turbine Bypass System inoperable requiring the use of TBVOOS limits. The TBVOOS analysis supports operation with all bypass valves inoperable.

TBVOOS operation coincident with FHOOS is supported using the combined TBVOOS/FHOOS limits.

SLO is not permitted with TBVOOS.

Feedwater Temperature Reduction Brunswick Unit 1, Cycle 17 may operate with RFWT over the entire MEOD range and cycle with applicable APLHGR, MCPR and LHGR limits as specified in the COLR. NFWT is defined as the range of feedwater temperatures from NFWT to NFWT - 10°F. NFWT and its allowable variation was assumed in the development of the Base Case Operation limits. The FHOOS limits and FFTR/Coastdown limits were developed for a maximum feedwater temperature reduction of 110.3°F.

The following must be considered when operating with RFWT:

Although the acronyms FWTR, FHOOS, RFWT and FFTR all involve reduced feedwater temperature, the use of FFTR is reserved for cycle energy extension using reduced feedwater temperature at and beyond a core average exposure of EOCLB using FFTR/Coastdown limits.

Prior to reaching the EOCLB exposure breakpoint, operation with FWTR >10°F and reactor power > 30% RTP requires use of the FHOOS limits. Below 30% RTP, Base Case Operation limits bound FHOOS limits.

Until a core average exposure of EOCLB is reached, implementation of the FFTR/Coastdown limits are not required even if coastdown begins early.

" When operating with RFWT, the appropriate Stability Option III Power/Flow Maps (Figures 5 and 6) must be used.

FHOOS operation coincident with TBVOOS is supported using the combined TBVOOS/FHOOS limits.

" SLO is not permitted with RFWT.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1B21-1287 B1C17 Core Operating Limits Report Page 14, Revision 0 References

1.

BNP Design Calculation 1B21-1287, "Preparation of the B1C17 Core Operating Limits Report,"

Revision 0.

2.

Design Calculation 0B21-1015, "BNP Power/Flow Maps," Revision 7.

3.

Design Calculation 1C51-0001, "BNP Power Range Neutron Monitoring System Setpoint Uncertainty and Scaling Calculation (1-C51-APRM 1 through 4 Loops and 1-C51-RBM-A and B Loops," Revision 2, October 2003.

4.

ANP-2674(P), "Brunswick Unit 1 Cycle 17 Reload Safety Analysis," Revision 2, March 2008.

5.

NEDC-31624P, "Loss-of-Coolant Accident Analysis Report for Brunswick Steam Electric Plant Unit 1 Reload 15 Cycle 16," Supplement 1, Revision 9.

6.

NEDO-31960-A, "BWR Owners Group Long-Term Stability Solutions Licensing Methodology,"

November 1995.

7.

NEDO-32465-A, "Reactor Stability Detect and Suppress Solutions Licensing Basis Methodology for Reload Application," August 1996.

8.

OG04-0153-260, "Plant-Specific Regional Mode DIVOM Procedure Guideline," June 15, 2004.

9.

BWROG-03047 "Resolution of Reportable Condition for Stability Reload Licensing Calculations Using Generic Regional Mode DIVOM Curve," September 30, 2003.

10.

OG02-0119-260 "Backup Stability Protection (BSP) for Inoperable Option III Solution, GE Nuclear Energy," July 17, 2002.

11.

NEDC-31654P, "Maximum Extended Operating Domain Analysis for Brunswick Steam Electric Plant," February 1989.

12.

NEDE-2401 1-P-A, "GESTAR II - General Electric Standard Application for Reactor Fuel."

13.

GENE-C51-00251-00-01, "Licensing Basis Hot Bundle Oscillation Magnitude for Brunswick 1 and 2," Revision 0, March 2001.,

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design CaIc. No. 1B21-1287 Page 15, Revision 0 Table 1 RBM System Setpoints' Setpoint a, d,

Trip Setpoint Allowable Value]

Lower Power Setpoint (LPSP )

27.7

< 29.0 Intermediate Power Setpoint (IPSP )

62.7

< 64.0 High Power Setpoint (HPSP )

82.7

< 84.0 Low Trip Setpoint (LTSPc)

< 114.1

< 114.6 Intermediate Trip Setpoint (ITSPc)

< 108.3

< 108.8 High Trip Setpoint (HTSPc)

<104.5

< 105.0 RBM Time Delay (td2)

< 2.0 seconds

< 2.0 seconds a

See Table 2 for RBM Operability Requirements.

b Setpoints in percent of Rated Thermal Power.

c Setpoints relative to a full scale reading of 125. For example, _ 114.1 means

< 114.11125.0 of fullscale.

d.

Trip setpoints and allowable values are based on a high power analytical

,setpoint of 108% (unfiltered).*

1 This table is referred to by Technical Specification 3.3.2.1 (Table 3.3.2.1-1) and 5.6.5.a.5.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1 C17 Core Operating Limits Report Design Calc. No. 1B21-1287 Page 16, Revision 0 Table 2 RBM Operability Requirements 2 IF the following conditions are met, THEN RBM Not Required Operable Thermal Power

(% rated)

MCPR

>Ž1.64 TLO

> 29% and < 90%

216 L

>d1.65 SLO

>90%

> 1.39 TLO 2

Requirements valid for all fuel designs, all SCRAM insertion times and all core average exposure ranges.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Table 3 PBDA Setpoints 3 Design Calc. No. 1B21-1287 Page 17, Revision 0 AmPlitudeTrip OLMCPR(SS)

OLMCPR(2PT),

Setpoint (Sr),

1.05 1.21 1.20 1.06 1.23 1.22 1.07 1.24 1.24 1.08 1.26 1.26 1.09 1.29 1.28 1.10 1.31 1.30 1.11 1.33 1.32 1.12 1.36 1.35 1.13 1.38 1.37 1.14 1.41 1.40 1.15 1.43 1.42 Acceptance' Criteria Off-rated OLMCPR @

Rated Power 45% Flow OLMCPR.

PDBA.SetpOint Setpoint Value Amplitude Trip (SP) 1.12 1.13 1.14 1.15 Confirmation Count (Np) 14 15 16 16 3

This table is referred to by Technical Specification 3.3.1.1 (Table 3.3.1.1-1) and 5.6.5.a.4.

ill Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1 C17 Core Operating Limits Report Table 4 Exposure Basis 4 for Brunswick Unit 1 Cycle 17 Transient Analysis Design Calc. No. 1B21-1287 Page 18, Revision 0 Core Average Exposure (MWd/MTU)

Comments 29,667 Break point for exposure-dependent MCPRp limits (NEOC) 32,076 Design basis rod patterns to EOFP + 14 EFPD (EOCLB) 33,841 End of reactivity for FFTR /Coastdown -

Maximum Core Exposure (MCE) 4 The exposure basis for the defined break points are the core average exposure (CAVEX) values shown above regardless of the actual BOC CAVEX value of the As-Loaded Core.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design CaIc. No. 1B21-1287 Page 19, Revision 0 Table 5 Power-Dependent MCPRp Limits 5 NSS Insertion Times BOC to < NEOC EOOS Power ATRIUM-10 GE14 Condition

(% rated)

MCPRP MCPRP 100.0 1.35 1.35 90.0 1.38 1.37 50.0 1.53 1.53 Base Case

> 65%F

< 65%F

< 50%F

> 65%F

< 65%F

< 50%F Operation 50.0 2.02 1.82 2.02 1.81 26.0 2.39 2.21 2.39 2.22 26.0 2.60 2.49 2.47 2.63 2.50 2.45 23.0 2.73 2.60 2.55 2.76 2.61 2.54 100.0 1.38 1.37 90.0 1.42 1.40 50.0 1.59 1.58

> 65%F

< 65%F

< 50%F

> 65%F

< 65%F

< 50%F 50.0 2.02 1.82 2.02 1.81 26.0 2.39 2.21 2.39 2.22 26.0 3.14 2.89 2.76 3.13 2.90 2.72 23.0 3.31 3.14 3.00 3.30 3.14 2.95 100.0 1.36 1.36 90.0 1.40 1.38 50.0 1.57 1.57

> 65%F

<65%F

< 50%F

> 65%F

< 65%F

< 50%F 50.0 2.02 1.82 2.02 1.81 26.0 2.39 2.21 2.39 2.22 26.0 2.60 2.49 2.47 2.63 2.50 2.45 23.0 2.73 2.60 2.55 2.76 2.61 2.54 100.0 1.42 1.39 90.0 1.45 1.42 TBVOOS 50.0 1.64 1.63 and

> 65%F

< 65%F

< 50%F

> 65%F

< 65%F

< 50%F FHOOS 50.0 2.02 1.82 2.02 1.81 26.0 2.39 2.21 2.39 2.22 26.0 3.14 2.89 2.76 3.13 2.90 2.72 23.0 3.31 3.14 3.00 3.30 3.14 2.95 Limits support operation with any combination of any 1 inoperable SRV, 1 inoperable TBV, up to 40% of the TIP channels out-of-service, and up to 50% of the LPRMs out-of-service. For single-loop operation, the TLO MCPRp limits shown above must be adjusted by adding 0.01. SLO not permitted for FHOOS, TBVOOS or MSIVOOS.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design CaIc. No. 1B21-1287 Page 20, Revision 0 Table 6 Power-Dependent MCPRp Limits 6 TSSS Insertion Times BOC to < NEOC EOOS Power ATRIUM-10 GE14 Condition

(% rated)

MCPRP MCPRP 100.0 1.46 1.43 90.0 1.47 1.45 50.0 1.55 1.54 Base Case

> 65%F

< 65%F

<50%F

> 65%F

<65%F

< 50%F Operation 50.0 2.06 1.84 2.04 1.83 26.0 2.41 2.21 2.41 2.22 26.0 2.60 2.49 2.47 2.63 2.50 2.45 23.0 2.73 2.60 2.55 2.76 2.61 2.54 100.0 1.49 1.46 90.0 1.52 1.49 50.0 1.65 1.64

> 65%F

< 65%F

< 50%F

> 65%F

<65%F

< 50%F TBVOOS 50.0 2.06 1.84 2.04 1.83 26.0 2.41 2.21 2.41 2.22 26.0 3.14 2.89 2.76 3.13 2.90 2.72 23.0 3.31 3.14 3.00 3.30 3.14 2.95 100.0 1.47 1.44 90.0 1.48 1.46 50.0 1.62 1.62

> 65%F

< 65%F

< 50%F

> 65%F

< 65%F

< 50%F 50.0 2.06 1.84 2.04 1.83 26.0 2.41 2.21 2.41 2.22 26.0

.2.60 2.49 2.47 2.63 2.50 2.45 23.0 2.73 2.60 2.55 2.76 2.61 2.54 100.0 1.50 1.47 90.0 1.53 1.50 TBVOOS 50.0 1.70 1.69 and

> 65%F

< 65%F

< 50%F

> 65%F

< 65%F

< 50%F FHOOS 50.0 2.06 1.84 2.04 1.83 26.0 2.41 2.21 2.41 2.22 26.0 3.14 2.89 2.76 3.13 2.90 2.72

.23.0 3.31 3.14 3.00 3.30 3.14 2.95 6

Limits support operation with any combination of any 1 inoperable SRV, 1 inoperable TBV, up to 40% of the TIP channels out-of-service, and up to 50% of the LPRMs out-of-service. For single-loop operation, the TLO MCPRp limits shown above must be adjusted by adding 0.01. SLO not permitted for FHOOS, TBVOOS or MSIVOOS.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Table 7 Power-Dependent MCPRp Limits7 NSS Insertion Times BOC to < EOCLB Design CaIc. No. 1B21-1287 Page 21, Revision 0 EOOS Power ATRIUM-10 GE14 Condition

(% rated)

MCPRP MCPRP 100.0 1.40 1.41 90.0 1.43 1.43 50.0 1.53 1.53 Base Case

> 65%F

< 65%F

< 50%F

> 65%F

< 65%F

< 50%F Operation 50.0 2.02 1.82 2.02 1.81 26.0 2.39 2.21 2.39 2.22 26.0 2.60 2.49 2.47 2.63 2.50 2.45 23.0 2.73 2.60 2.55 2.76 2.61 2.54 100.0 1.43 1.43 90.0 1.46 1.45 50.0 1.62 1.61

> 65%F

<65%F

<50%F

> 65%F

<65%F

<50%F TBVOOS 50.0 2.02 1.82 2.02 1.81 26.0 2.39 2.21 2.39 2.22 26.0 3.14 2.89 2.76 3.13 2.90 2.72 23.0 3.31 3.14 3.00 3.30 3.14 2.95 100.0 1.41 1.42 90.0 1.44 1.44 50.0 1.57 1.57

> 65%F

< 65%F

< 50%F

> 65%F

< 65%F

< 50%F 50.0 2.02 1.82 2.02 1.81 26.0 2.39 2.21 2.39 2.22 26.0 2.60 2.49 2.47 2.63 2.50 2.45 23.0 2.73 2.60 2.55 2.76 2.61 2.54 100.0 1.45 1.48 90.0 1.48 1.51 TBVOOS 50.0 1.64 1.63 and

> 65%F

  • 65%F

< 50%F

> 65%F

< 65%F

< 50%F FHOOS 50.0 2.02 1.82 2.02 1.81 26.0 2.39 2.21 2.39 2.22 26.0 3.14 2.89 2.76 3.13 2.90 2.72 23.0 3.31 3.14 3.00 3.30 3.14 2.95 Limits support operation with any combination of any 1 inoperable SRV, 1 inoperable TBV, up to 40% of the TIP channels out-of-service, and up to 50% of the LPRMs out-of-service. For single-loop operation, the TLO MCPRp limits shown above must be adjusted by adding 0.01. SLO not permitted for FHOOS, TBVOOS or MSIVOOS.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design CaIc. No. 1B21-1287 Page 22, Revision 0 Table 8 Power-Dependent MCPRp Limits 8 TSSS Insertion Times BOC to < EOCLB EOOS Power ATRIUM-10 GE14 Condition

(% rated)

MCPRP MCPRP 100.0 1.46 1.46 90.0 1.47 1.47 50.0 1.55 1.54 Base Case

> 65%F

< 65%F

< 50%F

> 65%F

< 65%F

< 50%F Operation 50.0 2.06 1.84 2.05 1'.83 26.0 2.41 2.21 2.41 2.22 26.0 2.60 2.49 2.47 2.63 2.50 2.45 23.0 2.73 2.60 2.55 2.76 2.61 2.54 100.0 1.49 1.48 90.0 1.52 1.50 50.0 1.65 1.64

> 65%F

-5 65%F 50%F

> 65%F 65%F 50%F TBVOOS 50.0 2.06 1.84 2.05 1.83 26.0 2.41 2.21 2.41 2.22 26.0 3.14 2.89 2.76 3.13 2.90 2.72 23.0 3.31 3.14 3.00 3.30 3.14 2.95 100.0 1.47 1.47 90.0 1.48 1.49 50.0 1.62 1.62

> 65%F

< 65%F 50%F

> 65%F

< 65%F 50%F 50.0 2.06 1.84 2.05 1.83 26.0 2.41 2.21 2.41 2.22 26.0 2.60 2.49 2.47 2.63 2.50 2.45 23.0 2.73 2.60 2.55 2.76 2.61 2.54 100.0 1.50 1.54 90.0 1.53 1.55 TBVOOS 50.0 1.70 1.69 and

> 65%F

< 65%F

< 50%F

> 65%F

< 65%F

< 50%F FHOOS 50.0 2.06 1.84 2.05 1.83 26.0 2.41 2.21 2.41 2.22 26.0 3.14 2.89 2.76 3.13 2.90 2.72 23.0 3.31 3.14 3.00 3.30 3.14 2.95 Limits support operation with any combination of any 1 inoperable SRV, 1 inoperable TBV, up to 40% of the TIP channels out-of-service, and up to 50% of the LPRMs out-of-service. For single-loop operation, the TLO MCPRp limits shown above must be adjusted by adding 0.01. SLO not permitted for FHOOS, TBVOOS or MSIVOOS.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design CaIc. No. 1B21-1287 Page 23, Revision 0 Table 9 Power-Dependent MCPRp Limits 9 NSS Insertion Times BOC to < MCE (FFTR/Coastdown)

EOOS 10 Power ATRIUM-10 GE14 Condition

(% rated)

MCPRP MCPRP 100.0 1.45 1.44 90.0 1.45 1.44 Base Case 50.0 1.57 1.57 Operation

> 65%F

< 65%F

< 50%F

> 65%F

< 65%F

< 50%F 50.0 2.02 1.82 2.02 1.81 (includes FHOOS) 26.0 2.39 2.21 2.39 2.22 26.0 2.60 2.49 2.47 2.63

.2.50 2.45 23.0 2.73 2.60 2.55 2.76 2.61 2.54 100.0 1.46 1.48 90.0 1.48 1.51 50.0 1.70 1.65 TBVOOS

> 65%F

<65%F

< 50%F

> 65%F

< 65%F

< 50%F (includes EHOOS) 50.0 2.02 1.82 2.02 1.81 26.0 2.39 2.21 2.39 2.22 26.0 3.14 2.89 2.76 3.13 2.90 2.72 1

23.0 3.31 3.14 3.00 3.30 3.14 2.95 Limits support operation with any combination of any 1 inoperable SRV, 1 inoperable TBV, up to 40% of the TIP. channels out-of-service, and up to 50% of the LPRMs out-of-service. For single-loop operation, the TLO MCPRp limits shown above must be adjusted by adding 0.01. SLO not permitted for FHOOS, TBVOOS or MSIVOOS.

10 FFTR included in Base Case Operation and TBVOOS.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1 C17 Core Operating Limits Report Design CaIc. No. 1B21-1287 Page 24, Revision 0 Table 10 Power-Dependent MCPRI Limits11 TSSS Insertion Times BOC to < MCE (FFTR/Coastdown)

EOOS 12 Power ATRIUM-10 GE14 Condition

(% rated)

MCPRp MCPRp 100.0 1.48 1.47 90.0 1.48 1.49 Base Case 50.0 1.62 1.62 Operation

> 65%F

< 65%F

< 50%F

> 65%F

< 65%F

< 50%F 50.0 2.06 1.84 2.05 1.83 (includes FHOOS) 26.0 2.41 2.21 2.41 2.22 26.0 2.60 2.49 2.47 2.63 2.50 2.45 23.0 2.73 2.60 2.55 2.76 2.61 2.54 100.0 1.50 1.54 90.0 1.53 1.55 50.0 1.70 1.69 TBVOOS

> 65%F

< 65%F

< 50%F

> 65%F

< 65%F

< 50%F (includes EHOOS) 50.0 2.06 1.84 2.05 1.83 26.0 2.41 2.21 2.41 2.22 26.0 3.14 2.89 2.76 3.13 2.90 2.72 23.0 3.31 3.14 3.00 3.30 3.14 2.95 Limits support operation with any combination of any 1 inoperable SRV, 1 inoperable TBV, up to 40% of the TIP channels out-of-service, and up to 50% of the LPRMs out-of-service. For single-loop operation, the TLO MCPRp limits shown above must be adjusted by adding 0.01. SLO not permitted for FHOOS, TBVOOS or MSIVOOS.

12 FFTR included in Base Case Operation and TBVOOS.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design Calc. No. 1B21-1287 Page 25, Revision 0 Table 11 Flow-Dependent MCPRf Limits 13 Core Flow ATRIUM-10/GE14

(% of rated)

MCPRf 0.0 1.55 31.0 1.55 100.0 1.20 107.0 1.20 13 Limits valid for all SCRAM insertion times and all core average exposure ranges.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design Calc. No. 1B21-1287 Page 26, Revision 0

.Table 12 ATRIUM-10 Steady-State LHGRss Limits Peak ATRIUM-10 Pellet Exposure LHGR (GWd/MTU)

(kW/ft) 0.0 13.4 18.9 13.4 74.4 7.1

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1B21-1287 B1C17 Core Operating Limits Report Page 27, Revision 0 Table 13 GE14 Steady-State LHGRss Limits 14 15 Peak GE14 Pellet Exposure LHGR (GWd/MTU)

(kW/ft)

All 13.4 14 GE14 LHGR limits are effectively monitored by GE14 MAPLHGR limits in accordance with the NRC approved methodology described in Reference 12.

15 GE14 LHGR limits do not have a power or flow dependency. Thus, the GE14 LHGRFACP and the LHGRFACf multipliers have a constant value of 1.0 under all conditions.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design CaIc. No. 1B21-1287 Page 28, Revision 0 Table 14 ATRIUM-10 Power-Dependent LHGRFACp NSS Insertion Times BOC to < EOCLB Multipliers 16 EOOS Power ATRIUM-10 Condition

(% rated)

LHGRFACP 100.0 1.00 80.0 1.00 50.0 0.94 Base Case

> 65%F

< 65%F

< 50%F Operation 50.0 0.67 0.77 26.0 0.57 0.62 26.0 0.53 0.57 0.60 23.0 0.51 0.55 0.59 100.0 0.99 80.0 0.96 50.0 0.87

> 65%F

< 65%F

< 50%F TBVOOS 50.0 0.67 0.77 26.0 0.57 0.62 26.0 0.44 0.49 0.55 23.0 0.42 0.46 0.50 100.0 1.00 80.0 0.99 50.0 0.91

> 65%F

< 65%F

< 50%F FHOOS 50.0 0.67 0.77 26.0 0.57 0.62 26.0 0.53 0.57 0.60 23.0 0.51 0.55 0.59 100.0 0.99 80.0 0.95 50.0 0.86 TBVOOS and

> 65%F

< 65%F

< 50%F EHOOS 50.0 0.67 0.77 26.0 0.57 0.62 26.0 0.44 0.49 0.55 23.0 0.42 0.46 0.50 16 Limits support operation with any combination of any 1 inoperable SRV, 1 inoperable TBV, up to 40% of the TIP channels out-of-service, and up to 50% of the LPRMs out-of-service.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1 C17 Core Operating Limits Report Design CaIc. No. 1B21-1287 Page 29, Revision 0 Table 15 ATRIUM-10 Power-Dependent LHGRFACp TSSS Insertion Times BOC to < EOCLB Multipliers 17 EOOS Power ATRIUM-10 Condition

(% rated)

LHGRFACp 100.0 1.00 80.0 0.94 50.0 0.93 Base Case

> 65%F

< 65%F

<50%F Operation 50.0 0.65 0.76 26.0 0.57 0.62 26.0 0.53 0.57 0.60 23.0 0.51 0.55 0.59 100.0 0.95 80.0 0.93 50.0 0.87

> 65%F

< 65%F

< 50%F 50.0 0.65 0.76 26.0 0.57 0.62 26.0 0.44 0.49 0.55 23.0 0.42 0.46 0.50 100.0 0.95 80.0 0.94 50.0 0.90

> 65%F

< 65%F

< 50%F 50.0 0.65 0.76 26.0 0.57 0.62 26.0 0.53 0.57 0.60 23.0 0.51 0.55 0.59 100.0 0.95 80.0 0.93 50.0 0.85 TBVOOS and

> 65%F

< 65%F

< 50%F FHOOS 50.0 0.65 0.76 26.0 0.57 0.62 26.0 0.44 0.49 0.55 1

23.0 0.42 0.46 0.50 17 Limits support operation with any combination of any 1 inoperable SRV, 1 inoperable TBV, up to 40% of the TIP channels out-of-service, and up to 50% of the LPRMs out-of-service.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design Caic. No. 1B21-1287 Page 30, Revision 0 Table 16 ATRIUM-10 Power-Dependent LHGRFACP Multipliers 18 NSS Insertion Times BOC to < MCE (FFTR/Coastdown)

EOOS 19 Power ATRIUM-10 Condition

(% rated)

LHGRFACP 100.0 1.00 80.0 0.97 Base Case 50.0 0.91 Operation

> 65%F

< 65%F

< 50%F 50.0 0.67 0.76 (includes FHOOS) 26.0 0.57 0.62 26.0 0.53 0.57 0.60 23.0 0.51 0.55 0.59 100.0 0.97 80.0 0.92 50.0 0.86 TBVOOS

> 65%F

< 65%F

< 50%F 50.0 0.67 0.76 (includes FHOOS)

5.

067.6 26.0 0.57 0.62 26.0 0.44 0.49 0.55 23.0 0.42 0.46 0.50 18 Limits support operation with any combination of any 1 inoperable SRV, 1 inoperable TBV, up to 40% of the TIP channels out-of-service, and up to 50% of the LPRMs out-of-service.

19 FFTR included in Base Case Operation and TBVOOS.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design CaIc. No. 1B21-1287 Page 31, Revision 0 Table 17 ATRIUM-10 Power-Dependent LHGRFACP TSSS Insertion Times BOC to < MCE (FFTR/Coastdown)

Multipliers 20 EOOS 2 1 Power ATRIUM-10 Condition

(% rated)

LHGRFACP 100.0 1.00 80.0 0.94 Base Case 50.0 0.89 Operation

> 65%F

< 65%F

< 50%F 50.0 0.65 0.74 (includes FHOOS) 26.0 0.57 0.62 26.0 0.53 0.57 0.60 23.0 0.51 0.55 0.59 100.0 0.95 80.0 0.91 50.0 0.85 TBVOOS

> 65%F

< 65%F

< 50%F (includes FHOOS 50.0 0.65 0.74 26.0 0.57 0.62 26.0 0.44 0.49 0.55 23.0 0.42 0.46 0.50 20 Limits support operation with any combination of any 1 inoperable SRV, 1 inoperable TBV, up to 40% of the TIP channels out-of-service, and up to 50% of the LPRMs out-of-service.

21 FFTR included in Base Case Operation and TBVOOS.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design Calc. No. 1B21-1287 Page 32, Revision 0 Table 18 ATRIUM-10 Flow-Dependent LHGRFACf Multipliers 22 Core Flow

(% of rated)

LHGRFACf 0.0 0.90 31.0 0.90 49.12 1.00 107.0 1.00 22 Multipliers valid for all SCRAM insertion times and all core average exposure ranges.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design Calc. No. 1B21-1287 Page 33, Revision 0 Table 19 ATRIUM-10 Steady-State MAPLHGRss Limits 23 24 Average Planar Exposure (GWd/MTU)

MAPLHGR (kW/ft) 0.0 12.5 15.0 12.5 67.0 7.3 23 ATRIUM-10 MAPLHGR limits do not have a power or flow dependency. Thus, the ATRIUM-10 MAPFACp and the MAPFACf multipliers have a constant value of 1.0 under all conditions.

24 ATRIUM-10 MAPLHGR limits must be adjusted by a 0.85 multiplier when in SLO. SLO not permittedfor FHOOS, TBVOOS or MSIVOOS.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1B21-1287 B1C17 Core Operating Limits Report Page 34,- Revision 0 Table 20 GE14 Steady-State MAPLHGRss Limits 25 GEl 4-P1ODNAB416-17GZ-10OT-150-T-2496 (only)

Average Planar Exposure Limit (GWd/MTU)

(kW/ft) 0.00 9.27 0.22 9.33 1.10 9.44 2.20 9.59 3.31 9.76 4.41 9.93 5.51 10.11 6.61 10.30 7.72 10.50 8.82 10.71

.9.92 10.91 11.02 11.12 12.13 11.31 13.23 11.36 14.33 11.35 15.43 11.34 16.53 11.31 18.74 11.23 22.05 11.03 27.56 10.60 33.07 10.12 38.58 9.49 44.09 8.91 49.60 8.37 55.12 7.87 60.63 6.53 64.27 4.88 25 The GE14 MAPLHGR limits presented in this COLR are a composite set of limits based on the most limiting MAPLHGR limits from each lattice.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1B21-1287 B1C17 Core Operating Limits Report Page 35, Revision 0 Table 21 GE14 Steady-State MAPLHGRss Limits 26 GE14-P1ODNAB413-16GZ-10T-1 50-T-2660 (only)

Average Planar Exposure Limit (GWd/MTU)

(kW/ft) 0.00 9.57 1.10 9.66 2.20 9.77 3.31 9.92 4.41 10.08 5.51 10.26 6.61 10.44 7.72 10.59 8.82 10.74 9.92 10.87 11.02 11.00 12.13 11.12 13.23 11.15 14.33 11.16 15.43 11.16 15.99 11.16 16.53 11.16 18.74 11.13 21.09 11.02 22.05 10.98 27.56 10.57 33.07 10.15 38.58 9.65 44.09 9.12 49.60 8.59 55.12 8.04 60.63 6.48 63.50 5.18 64.16 4.88 26 The GE14 MAPLHGR limits presented in this COLR are a composite set of limits based on the most limiting MAPLHGR limits from each lattice.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1B21-1287 B1C17 Core Operating Limits Report Page 36, Revision 0 Table 22 GEl4 Steady-State MAPLHGRss Limits 27 GE 14-PIODNAB429-18GZ-10OT-150-T-2661 (only)

Average Planar Exposure Limit (GWd/MTU)

(kW/ft) 0.00 8.89 1.10 9.05 2.20 9.16 3.31.

9.29 4.41 9.43 5.51 9.55 6.61 9.68 7.72 9.81 8.82 9.94 9.92 10.08 11.02 10.23 12.13 10.28 13.23 10.31 14.33 10.34 15.43 10.37 15.99 10.39 16.53 10.41 18.74 10.49 21.09 10.53 22.05 10.55 27.56 10.35 33.07 9.89 38.58 9.43 44.09 8.95 49.60 8.45 55.12 7.92 60.63 5.83 62.51 4.97 27 The GE14 MAPLHGR limits presented in this COLR are a composite set of limits based on the most limiting MAPLHGR limits from each lattice.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1 B21-1287 B1 C17 Core Operating Limits Report Page 37, Revision 0 Table 23 GE14 Steady-State MAPLHGRss Limits 28 GE 14-P1ODNAB437-12G6.0-10OT-150-T-2662 (only)

Average Planar Exposure Limit (GWd/MTU)

(kW/ft) 0.00 9.06 1.10' 9.20 2.20 9.31 3.31 9.43 4.41 9.55 5.51 9.68 6.61 9.81 7.72 9.95 8.82 10.09 9.92 10.23 11.02 10.38 12.13 10.45 13.23 10.48 14.33 10.51 15.43 10.54 16.00 10.55 16.53 10.56 18.74 10.56 21.09 10.49 22.05 10.47 27.56 10.20 33.07 9.87 38.58 9.42 44.09 8.95 49.60 8.45 55.12 7.91 60.63, 5.56 62.02 4.91 28 The GE14 MAPLHGR limits presented in this COLR are a composite set of limitsbased on the most limiting MAPLHGR limits from each lattice.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1B21-1287 B1C17 Core Operating Limits Report Page 38, Revision 0 Table 24 GEl4 Steady-State MAPLHGRss Limits 29 GE14-P1ODNAB407-16GZ-10OT-150-T-2853 (only)

Average Planar Exposure Limit (GWd/MTU)

(kW/ft) 0.00 9.47 1.10 9.71 2.20 9.87 3.31 10.02 4.41 10.17 5.51 10.31 6.61 10.45 7.72 10.57 8.82 10.70 9.92 10.82 11.02 10.93 12.13 11.05 13.23 11.06 14.33 11.05 15.43 11.05 16.00 11.05 16.53 11.05 18.74 11.02 21.09 10.91 22.05 10.87 27.56 10.49 33.07 10.08 38.58 9.58 44.09 9.07 49.60 8.54 55.12 7.99 60.63 6.34 63.50 5.03 63.84 4.88 29 The GE14 MAPLHGR limits presented in this COLR are a composite set of limits based on the most limiting MAPLHGR limits from each lattice.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1B21-1287 B1C17 Core Operating Limits Report Page 39, Revision 0 Table 25 GE14 Steady-State MAPLHGRss Limits 30 GE14-P1ODNAB425-18GZ-10OT-150-T-2854 (only)

Average Planar Exposure Limit (GWd/Mt)

(kW/ft) 0.00 8.85 1.10 9.01 2.20 9.14 3.31 9.27 4.41 9.41 5.51 9.54 6.61 9.68 7.72 9.82 8.82 9.95 9.92 10.09 11.02 10.23 12.13 10.27 13.23 10.29 14.33 10.31 15.43 10.34 16.00 10.35 16.53 10.37 18.74 10.44 21.09 10.47 22.05 10.48

.27.56 10.28 33.07 9.84 38.58 9.38 44.09 8.91 49.60 8.41 55.12 7.88 60.63 5.70 62.23 4.96 30 The GE14 MAPLHGR limits presented in this COLR are a composite set of limits based on the most limiting MAPLHGR limits from each lattice.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1B21-1287 B1C17 Core Operating Limits Report Page 40, Revision 0 Table 26 GEl 4 Power-Dependent MAPFACP Multipliers 31 32 EOOS Power GE14 Condition

(% rated)

MAPFACP 100.0 1.00 50.0 0.73 Base Case

> 65%F

< 65%F

<50%F Operation 50.0 0.62 0.72 (includes FHOOS) 26.0 0.53 0.60 26.0 0.43 0.49 0.56 23.0 0.41 0.45 0.51 100.0 1.00 50.0 0.73 TBVOOS

> 65%F

< 65%F

< 50%F 50.0 0.62 0.72 (includes FHOOS) 26.0 0.53 0.60 26.0 0.42 0.48 0.53 23.0 0.40 0.44 0.49 31 Multipliers valid for all SCRAM insertion times and all core average exposure ranges.

32 The GE14 power-dependent and flow-dependent multipliers are capped at 0.80 when in SLO. SLO not permitted for FHOOS, TBVOOS or MSIVOOS.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Design Calc. No. 1B21-1287 Page 41, Revision 0 Table 27 GE14 Flow-Dependent MAPFACf Multipliers 33 Core Flow GE14

(% rated)

MAPFACf 0.0 0.56 31.0 0.56 80.0 1.00 107.0 1.00 33 The GE14 power-dependent and flow-dependent multipliers are capped at 0.80 when in SLO. SLO not permitted for FHOOS, TBVOOS or MSIVOOS.

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Figure 1 Stability Option II Power/Flow Map OPRM Operable, Two Loop Operation, 2923 MWt Design Caic. No. 1 B21-1287 Page 42, Revision 0 This Figure supports Improved Technical Specification 3.3.1.1 and the Technical Requirements Manual Specification 3.3:]

120.0 110.0 100.0 90.0 80.0 70.0 60.0 Minimum Maximum (MELLL)

(ICF)

Core Core Power Flow Flow Mths/hr

.Mlbs/hL 100 76.19 80.47 99 75.04 80.47 98 73.89 80.47 97 72.75 80.47 96 71.61 80.47 95 70.49 80.47 94 69.36 80.47 93 68.25 80.47 92 67.13 80.47 91 66.03 80.47 90 64.93 80.47 89 63.83 80.47 88 62.74 80.47 87 61.66 80.51 86 60.58 80.60 85 59.50 80.69 84 58.43 80.79 83 57.37 80.90 82 56.31 81.05 81 55.25 81.21 80 54.20 81.36 79 53.16 81.51 78 52.12 81.67 77 51.08 81.82 76 50.05 81.98 75 49.02 82.13 74 48.00 82.29 73 46.98 82.44 72 45.96 82.60 71 44.95 82.75 70 43.94 82.91 69 42.94 83.06 66 41.94 83.22 67 40.95 83.37 66 39.96 83.52 65 38.97 83.68 64 37.99 83.83 63 37.01 83.99 62 36.04 84.14 61 35.06 84.30 60 34.10 84.45 59 33.13 84.61 58 32.17 84.70 50.0 40.0 30.0 20.0 10.0 U.U II I I I

o 0.0 7.7 15.4 23.1 30.8 38.5 46.2 53.9 61.6 69.3 77.0 84.7 92.4 Mlbs/hr Core Flow 0

10 20 30 40 50 60 70 80 90 100 110 120

% Core Flow

Reference:

0821-1015, Revision 7

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Calc. No. 1B21-1287 B1C17 Core Operating Limits Report Page 43, Revision 0 Figure 2 Stability Option III Power/Flow Map OPRM Inoperable, Two Loop Operation, 2923 MWt This Figure supports Improved Technical Specification 3.3.1.1 and the Technical Requirements Manual Specification 3=.

120.0 Minimum Maximum (MELLL)

(lCP) 110.0 C

S l !

Core Core Mlbs/hr Mlhbshr APRM STP Rod Block 10o 76.29 30.47 F 1+

M*+!

99 7S.04 8so.47 100.0 97 72.75 80.47 j 01 96 71.61 80.47 95 70.49 30.47 90094 69.36 80.47 t93 68.25 80.47 992 67.13 80.47 91 66.03 80.47 80.0 00+

90 64.93 80.47 89 63.83 80.47 88 62.74 80.47 87 61.66 80.51 70086 60.58 80.60 85 59.50 80.69 83 57.37 80.90 60.0 82 56.31 81.05 0.81 55.25 81.21 80 54.20 81.36 79 53.16 81.51 50.0 R1 78 52.12 81.67 MLLUe-76 50.05 81.98 I;

II.Ey Li g75 49.02 82.13 400 eio A-Maua CRM74 48.00 82.29

40.

R~oA ~flaISCAM73 46.98 82.44 072 45.96 82.60 n71 44.95 82.75 8Rý B-Immediate E-xit I70 43.94 82.91 30.0 Rein69 42.94 83.06 20065 38.97 83.68 64 37.99 83.83 Naual63 37.01 83.99

'A 59 33.13 84.61 0035%

MWinUimum Pu-mp5.Ip, MinimumIE Powe.r un.

58 32.17 84.70 1

0.0 7.7 15.4 23.1 30.8 38.5 46.2 53.9 61.6 69.3 77.0 84.7 92.4 Mlbslhr Core Flow 0

10 20 30 40 50 60 70 80 90 100 110 120

% Core Flow

Reference:

0B21-1015, Revision 7

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1C17 Core Operating Limits Report Figure 3 Stability Option III Power/Flow Map OPRM Operable, Single Loop Operation, 2923 MWt Design Calc. No. 1 B21-1287 Page 44, Revision 0 This Figure supports Improved Technical Specification 3.3.1.1 and the Technical Requirements Manual Specification 3.3 120.0 1 1

1 110.0 100.0 90.0 80.0 70.0 c

60.0 50.0 40.0 30.0 20.0 10.0 Minimum Maximum (MELLL I

( ICFI Core Core Power Flow Flow O

M lbs/h r Ml 100 76.19 80.47 99 75.04 80.47 98 73.89 80.47 97 72.75 80.47 96 71.61 80.47 95 70.49 80.47 94 69.36 80.47 93 68.25 80.47 92 67.13 80.47 91 66.03 80.47 90 64.93 80.47 89 63.83 80.47 88 62.74 80.47 87 61.66 80*51 86 60.58 80g60 85 59.50 80,69 84 58.43 80.79 83 57.37 80.90 82 56.31 81.05 81 55.25 81.21 80 54.20 81.36 79 53.16 81.51 78 52.12 81.67 77 51.08 81.82 76 50.05 81.98 75 49.02 82.13 74 48.00 82.29 73 46.98 82.44 72 45.96 82.60 71 44.95 82.75 70 43.94 82.91 69 42.94 83.06 68 41.94 83.22 67 40.95 83.37 68 39.96 83.52 65 38.97 83.68 64 37.99 83.83 63 37.01 83.99 62 36.04 84.14 61 35.06 84.30 60 34.10 84.45 59 33.13 84.61 58 32.17 84.70 0.0 0.0 7.7 15.4 23.1 30.8 38.5 46.2 53.9 61.6 69.3 77.0 84.7 92.4 Mlbs/hr Core Flow 0

10 20 30 40 50 60 70 80 90 100 110 120

% Core Flow

Reference:

0B21-1015, Revision 7

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis Design Caic. No. 1B21-1287 B1C17 Core Operating Limits Report Page 45, Revision 0 Figure 4 Stability Option III Power/Flow Map OPRM Inoperable, Single Loop Operation, 2923 MWt This Figure supports Improved Technical Specification 3.3.1.1 and the Technical Requirements Manual Specification 3.3 120.0 Minimum Maximum STP,

i' MELLL I

[" ICF I Core Core Power Flow Flow 100 76.19 80.47 100.0 99 73.8904 80.47 APRM 97 72.75 80.47 STP Rod 96 71.61 80.47

  • *+

°0"

-100*

95 70.49 80.47 90.0 Block 94 69.36 80.47

÷ **'

  • 93 68.25 90*47
  • 4*

÷*.92 67.13 90.47 91 66.03 80.47 80.0 90 64.93 80.47

.89 63.83 80.47

.,.+.*

    • ...83 62.74 90.47

-100 -.

00

,87 61.66 80.51 70.0 86 60.58 80.60 85 59.50 80.69 00 84 58.43 80.79

i.

+..

8 3 5 7.3 7 80.9 0 60.0 82 56.31 81.05 81 55.25 81.21 80 54.20 81.36 79 53.16 81.51 50.0 R78 52.12 81.67 77 51.08 81.82 76 50.05 81.98 75 49.02 82.13 40.0 RgoA

-74 48.00 82.29 73 46.98 82.44 72 45.96 82.60 71 44.95 82.75 Regio B" -Exi 70 43.94 82.91 69 42.94 83.06 68 41.94 83.22 5% Bfe Regi67 40.95 83.37 66 39.96 83.52 20.0 46 5

Ma Core 65 38.97 83.68 64 37.99 83.833 Na-MI 63 37.01 83.99

-1 OPRM Enabled Region 6

6.4 941 S62 36.04 84.14 10.0 61 35.06 84.30 60 34.10 84.45 59 33.13 84.61

.0. L t 2N0=

35% Mpin I POW J

58 32.17 84.70 0.0" 0.0 7.7 15.4 23.1 30.8 38.5 46.2 53.9 61.6 69.3 77.0 84.7 92.4 Mlbs/hr Core Flow 0

10 20 30 40 50 60 70 80 90 100 110 120

% Core Flow

Reference:

0B21-1015, Revision 7

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis B1 C17 Core Operating Limits Report Figure 5 Stability Option III Power/Flow Map OPRM Operable, FWTR, 2923 MWt Design Calc. No. 1B21-1287 Page 46, Revision 0 This Figure supports Improved Technical Specification 3.3.1.1 and the Technical Requirements Manual Specification 3.3 120.0 110.0 100.0 90.0 80.0 70.0 60.0 a.

50.0 40.0 30.0 20.0 10.0 Minimum Maximum (MELLL)

(ICF)

Core Core Power Flow Flow O

Mlbs/hr J.bzl 100 76.19 80.47 99 75.04 80.47 98 73.89 80.47 97 72.75 80*47 96 71.61 80.47 95 70.49 80.47 94 69.36 80.47 93 68.25 80.47 92 67.13 80.47 91 66.03 80.47 90 64.93 80.47 89 63.83 80.47 88 62.74 80.47 87 61.66 80.51 86 60.58 80.60 85 59.50 80.69 84 58.43 80.79 83 57.37 80.90 82 56.31 81.05 81 55.25 81.21 80 54.20 81.36 79 53.16 81.51 78 52.12 81.67 77 51.08 81.82 76 50.05 81.98 75 49.02 82.13 74 48.00 82.29 73 46.98 82.44 72 45.96 82.60 71 44.95 82.75 70 43.94 82.91 69 42.94 83.06 68 41.94 83.22 67 40.95 83.37 66 39.96 83.52 65 38.97 83.68 64 37.99 83.83 63 37.01 83.99 62 36.04 84.14 61 35.06 84.30 60 34.10 84.45 59 33.13 84.61 58 32.17 84.70 0.0 0.0 7.7 15.4 23.1 30.8 38.5 46.2 53.9 61.6 69.3 77.0 84.7 92.4 Mlbslhr Core Flow 0

10 20 30 40 50 60 70 80 90 100 110 120

%CoreFlow

Reference:

0B21-1015, Revision 7

Progress Energy Nuclear Fuels Mgmt. and Safety Analysis BIC17 Core Operating Limits Report Figure 6 Stability Option III Power/Flow Map OPRM Inoperable, FWTR, 2923 MWt Design Caic. No. IB21-1287 Page 47, Revision 0 I This Figure supports Improved Technical Specification 3.3.1.1 and the Technical Requirements Manual Specification 3.3 1 120.0 110.0 100.0 90.0 80.0 70.0 60.0 50.0 40.0 30.0 Minimum Maximum (MELLL)

([ICF)

Core Core Power Flow Flow OA Mlbh/hr Mlr 100 76.19 80.47 99 75.04 80.47 98 73.89 80'47 97 72.75 80'47 96 71.61 80.47 95 70.49 80.47 94 69.36 80.47 93 68.25 80.47 92 67.13 80.47 91 66.03 80.47 90 64.93 80.47 89 63.83 80.47 88 62.74 80.47 87 61.66 80.51 86 60.58 80.60 85 59.50 80.69 84 58.43 80.79 83 57.37 80.90 82 56.31 81.05 81 5S.25 81.21 80 54.20 81.36 79 53.16 81.51 78 52.12 81.67 77 51.08 81.82 76 50.05 81.98 75 49.02 82.13 74 48.00 82.29 73 46.98 82.44 72 45.96 82.60 71 44.95 82.75 70 43.94 82.91 69 42.94 83.06 68 41.94 83.22 67 40.95 83.37 66 39.96 83.52 65 38.97 83.68 64 37.99 83.83 63 37.01 83.99 62 36.04 84.14 61 35.06 84.30 60 34.10 84.45 59 33.13 84.61 58 32.17 84.70 20.0 t 10.0 0.0 0.0 7.7 15.4 23.1 30.8 38.5 46.2 53.9 61.6 69.3 77.0 84.7 92.4 Mlbs/hr Core Flow 0

10 20 30 40 50 60 70 80 90 100 110 120

%CoreFlow

Reference:

0B21-1015, Revision 7