REGULATORY GUIDE 6.4 CLASSIFICATION OF CONTAINMENT PROPERTIES

OF SEALED RADIOACTIVE SOURCES CONTAINED IN

CERTAIN DEVICES TO BE DISTRIBUTED FOR USE UNDER GENERAL LICENSE

A. INTRODUCTION

sources (USASI N5.10. 1968).' To classify a sealed source under the system, a determination is made of its Section 32.51, "Certain Measuring, Gauging or ability to withstand the conditions of each Controlling Devices Gencrally Licensed Under §31.5 of environmental test prescribed in the standard.

this Chapter: Requirements for License to Distribute," Classification is determined by physically testing two of 10 CFR Part 32, "Specific Licenses to Manufacture, prototype sources for each test or by calculations based Distribute, or Import Exempted and Generally Licensed on previous tests which demonstrate that, if the source Items Containing Byproduct Material," requires, in part, were tested, it would pass. Maintenance of containment that each application for a specific license to distribute integrity after each test constitutes satisfactory devices containing byproduct material to persons performance of a source.

generally licensed under §31.5 of IOCFR Part 31 include sufficient information relating to qualification

C. REGULATORY POSITION

testing of a prototype unit to provide reasonable assurance that the byproduct material contained in the The sealed source classification system contained in device will not be lost. Frequently, retention of the USASI N5.10.1968' provides acceptable terminology byproduct material within the device is dependent upon for use in describing the containment properties of a the containment properties of a. sealed source. This sealed source used in a device intended for distribution regulatory guide identifies terminology acceptable to the for use under the general license in §31.5 of I0 CFR

Regulatory staff for describing the containment Part 31. When the classification system is so used, the properties of a sealed source based on prototype testing. applicant should state whether calculational techniques or physical testing techniques were applied. If the latter were applied, the integrity (leak) test(s) used to determine conformity with the assigned classification

B. DISCUSSION

should be identified and described.

The USA Standards Institute Committee N5.4, now Copies may be obtained from the American National the American National Standards Institute Committee Si-ndards Institute, Inc., 1430 Broadway. New York, New York N43-3.3, developed a classification system for sealed 10018.

USAEC REGULATORY GUIDES Copies of published guid"t may be obtained by request indicating the divisions desired to the US. Atomic Energy Commission. Washington. DC. 20546, Regulatory Guiclies ere Islued to teIVTbae and make available to the public Attention: Director of Regulatory Stendards. Comments end suggestions for rmethods acocptable to the AEC Regulatory staff of Implemenling specilic pi4t1 Of Improvements In these gutdes aweencouraged and should be sent to the Secretary the Commrislon's reIsetions. to delineate techniques used by the Itaff IM of the Commission, U.S. Atomic Energiy Commsttion, Washington. D.C. 70545, evaluting specdiic robtolornt or postulated aciciadn.t of to provide guidence 1o Attention: Chief, Public Proosedinp Staff.

appliants. Regutltory Guides a not tubltiltutes Cx regulations and compliance with them Is not required. Methods and eolutlons different from those wt out in The guide$ are issued in Ithe following len broad divisions:

the gulde will be accepteble if they provide a tails for the findings requisite to the isuanceor continuance of a permit of license by the Comrmslstion. 1. Power Reactors

d. Products

2. Reaseardh and Test Reactors

7. Transportation

3. Fuels and Materietl Facilities a. Occuolalonal Health PublIshedI gudes will be revised periodically, at appropriate, to eccommodate 4. Environmmentl an-dSilIng 9. Antitrust Review comments end to reflect new Intorn"tlon or espeflence. 6. Meteslels and Plant Protectltor 10. Ge*eral