ML080870420

From kanterella
Jump to navigation Jump to search

Tec Specs to Amd.152/Limerick 2/License NPF-85
ML080870420
Person / Time
Site: Limerick  Constellation icon.png
Issue date: 05/29/2008
From:
NRC/NRR/ADRO/DORL/LPLI-2
To:
Bamford, Peter J., NRR/DORL 415-2833
Shared Package
ml080870366 List:
References
TAC MD5937, TAC MD5938
Download: ML080870420 (3)


Text

(4) Pursuant to the Act and 10 CFR Parts 30, 40, 70, to receive, possess, and use in amounts as required any byproduct, source or special nuclear material without restriction to chemical or physical form, for sample analysis or instrument calibration or associated with radioactive apparatus or components; and (5) Pursuant to the Act and 10 CFR Parts 30, 40 and 70, to possess, but not separate, such byproduct and special nuclear materials as may be produced by the operation of the facility, and to receive and possess, but not separate, such source, byproduct, and special nuclear materials as contained in the fuel assemblies and fuel channels from the Shoreham Nuclear Power Station.

C. This license shall be deemed to contain and is subject to the conditions specified in the Commission's regulations set forth in 10 CFR Chapter I (except as exempted from compliance in Section 2.D. below) and is subject to all applicable provisions of the Act and to the rules, regulations, and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified or incorporated below:

(1) Maximum Power Level Exelon Generation Company is authorized to operate the facility at reactor core power levels of 3458 megawatts thermal (100 percent rated power) in 'accordance with the conditions specified herein.

(2) Technical Specifications The Technical Specifications contained in Appendix A and the Environmental Protection Plan contained in Appendix B, as revised through Amendment No. 152 , are hereby incorporated into this license. Exelon Generation Company shall operate the facility in accordance with the Technical Specifications and the Environmental Protection Plan.

(3) Fire Protection (Section 9.5, SSER-2, -4)*

Exelon Generation Company shall implement and maintain in effect all provisions of the approved Fire Protection Program as described in the Updated Final Safety Analysis Report for the facility, and as approved in the NRC Safety Evaluation Report dated August 1983 through Supplement 9, dated August 1989, and Safety Evaluation dated November 20, 1995, subject to the following provision:

The licensee may make changes to the approved fire protection program without prior approval, of the Commission only ifthose changes would not adversely affect the ability to achieve and maintain safe shutdown in the event of a fire.

  • The parenthetical notation following the title of license conditions, denotes the section of the Safety Evaluation Report and/or its supplements wherein the license condition is discussed.

Amendment No. 4, 27, 54, 68, 92,-1-08 1 52

TABLE 3.3.7.5-1 ACCIDENT MONITORING INSTRUMENTATION MINIMUM APPLICABLE REQUIRED NUMBER CHANNELS OPERATIONAL INSTRUMENT OF CHANNELS OPERABLE CONDITIONS ACTION

1. Reactor Vessel Pressure 2 1 1,2 80
2. Reactor Vessel Water Level 2 1 1,2 80
3. Suppression Chamber Water Level 2 1 1,2 80
4. Suppression Chamber Water Temperature 8, 6 locations 6, 1,2 80 1/location
5. Del eted
6. Drywell Pressure 2 1 1,2 80
7. Deleted
8. Deleted
9. Deleted
10. Deleted
11. Primary Containment Post-LOCA Radiation Monitors 4 2 1,2,3 81
12. North Stack Wide Range Accident Monitor** 3* 3* 1,2,3 81
13. Neutron Flux 2 1 1,2 80 LIMERICK - UNIT 2 3/4 3-85 Amendment No. 4--i, --3-5, 441 152

TABLE 4.3.7.5-1 ACCIDENT MONITORING INSTRUMENTATION SURVEILLANCE REQUIREMEN TS CHANNEL CHANNEL INSTRUMENT CHECK (a) CALIBRATION (a)

1. Reactor Vessel Pressure
2. Reactor Vessel Water Level
3. Suppression Chamber Water Level
4. Suppression Chamber Water Temperature
5. Deleted
6. Primary Containment Pressure
7. Deleted
8. Deleted
9. Deleted
10. Deleted
11. Primary Containment Post LOCA Radiatioon Monitors
12. North Stack Wide Range Accident Monitoor***
13. Neutron Flux (a) Frequencies are specified in the Surveillance Frequency Control Program unless otherwise noted in the table.
    • CHANNEL CALIBRATION shall consist of an electronic calibration of the channel, not including the detector, for range decades above 10 R/h and a one point calibration check of the detector below 10 R/h with an installed or portable gamma source.
      • High range noble gas monitors.

LIMERICK - UNIT 2 3/4 3-87 Amendment No. ;9, 4-3-5, 4-44, 4-4-152