ML080520225

From kanterella
Jump to navigation Jump to search

License and Technical Specification Pages, Amendment No. 275, Revise Limiting Condition for Operation for Technical Specification 3.1.3.4, Reactivity Control Systems CEA (Control Element Assembly) Drop Time
ML080520225
Person / Time
Site: Arkansas Nuclear 
(NPF-006)
Issue date: 03/05/2008
From:
NRC/NRR/ADRO/DORL/LPLIV
To:
Wang, A B, NRR/DORL/LPLIV, 415-1445
Shared Package
ML080520210 List:
References
TAC MD6627
Download: ML080520225 (2)


Text

facility at the designated location in Pope County, Arkansas in accordance with the procedures and limitations set forth in this renewed license; (3)

EOI, pursuant to the Act and 10 CFR Part 70, to receive, possess and use at any time at the facility site and as designated solely for the facility, special nuclear material as reactor fuel, in accordance with the limitations for storage and amounts required for reactor operation, as described in the Final Safety Analysis Report, as supplemented and amended; (4)

EOI, pursuant to the Act and 10 CFR Parts 30, 40 and 70 to receive, possess and use at any time any byproduct, source and special nuclear material as sealed neutron sources for reactor startup, sealed sources for reactor instrumentation and radiation monitoring equipment calibration, and as fission detectors in amounts as required; (5)

EOI, pursuant to the Act and 10 CFR Parts 30, 40 and 70, to receive, possess, and use in amounts as required any byproduct, source or special nuclear material without restriction to chemical or physical form, for sample analysis or instrument calibration or associated with radioactive apparatus or components; and (6)

EOI, pursuant to the Act and 10 CFR Parts 30 and 70, to possess, but not separate, such byproduct and special nuclear materials as may be produced by the operation of the facility.

C.

This renewed license shall be deemed to contain and is subject to conditions specified in the following Commission regulations in 10 CFR Chapter 1; Part 20, Section 30.34 of Part 30, Section 40.41 of Part 40, Sections 50.54 and 50.59 of Part 50, and Section 70.32 of Part 70; and is subject to all applicable provisions of the Act and to the rules, regulations, and orders of the Commission now or hereafter in effect; and is subject to the additional conditions specified or incorporated below:

(1)

Maximum Power Level EOI is authorized to operate the facility at steady state reactor core power levels not in excess of 3026 megawatts thermal. Prior to attaining this power level EOI shall comply with the conditions in Paragraph 2.C.(3).

(2)

Technical Specifications The Technical Specifications contained in Appendix A, as revised through Amendment No. are hereby incorporated in the renewed Renewed License No. NPF-6 Amendment No.

275 275

ARKANSAS - UNIT 2 3/4 1-23 Amendment No. 84,94,100,169, Correction Letter dated 10/24/95 REACTIVITY CONTROL SYSTEMS CEA DROP TIME LIMITING CONDITION FOR OPERATION 3.1.3.4 The individual CEA drop time, from a fully withdrawn position, shall be d 3.7 seconds and the arithmetic average of the CEA drop times of all CEAs, from a fully withdrawn position, shall be d 3.2 seconds from when the electrical power is interrupted to the CEA drive mechanisms until the CEAs reach their 90 percent insertion positions with:

a.

Tavg t 525°F, and

b.

All reactor coolant pumps operating.

APPLICABILITY:

MODES 1 and 2.

ACTION:

a.

With the CEA drop times determined to exceed either of the above limits, restore the CEA drop times to within the above limits prior to proceeding to MODE 1 or 2.

b.

With the CEA drop times within limits but determined at less than full reactor coolant flow, operation may proceed provided THERMAL POWER is restricted to less than or equal to the maximum THERMAL POWER level allowable for the reactor coolant pump combination operating at the time of CEA drop time determination.

SURVEILLANCE REQUIREMENTS 4.1.3.4 The CEA drop time of all CEAs shall be demonstrated through measurement prior to reactor criticality:

a.

For all CEAs following each removal of the reactor vessel head,

b.

For specifically affected individuals CEAs following any maintenance on or modification to the CEA drive system which could affect the drop time of those specific CEAs, and

c.

At least once per 18 months.

275