January 31, 2008 LICENSEE:

DUKE POWER COMPANY LLC (DUKE)

FACILITY:

OCONEE NUCLEAR STATION, UNITS 1, 2, AND 3 (OCONEE)

SUBJECT:

SUMMARY

OF JANUARY 24, 2008, MEETING TO DISCUSS OCTOBER 16, 2007, LICENSE AMENDMENT REQUEST (LAR) THAT PROPOSES MODIFICATONS TO MITIGATE WATER HAMMERS (TAC NOS. MD7000, MD7001, AND MD7002)

On January 24, 2008, the U.S. Nuclear Regulatory Commission (NRC) staff met with Duke (the licensee) to discuss the October 16, 2008, LAR that proposes modifications to mitigate water hammer. The October 16, 2008, LAR is available in the Agencywide Documents Access and Management System (ADAMS) under accession number ML072920449. The handouts provided by the licensee during the meeting are available under ADAMS accession number ML080250274. Enclosed is a list of the attendees.

The licensee discussed its proposed modification that will install check valves in the low-pressure service water (LPSW) supply header and automatic pneumatic discharge isolation valves, controllable vacuum breaker valves, and associated circuitry in the LPSW return header to isolate engineered safeguards portions of the LPSW system. The modification is intended to eliminate water hammers. The licensee also discussed proposed changes to the Technical Specifications associated with the modification.

The licensee stated that it intends to implement the modification on Unit 2 during the fall 2008 refueling outage, and requested that the amendments be issued by October 2008. The NRC staff stated that it could support that schedule.

/RA/

Leonard N. Olshan, Project Manager Plant Licensing Branch II-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287

Enclosure:

List of Attendees cc w/encl: See next page

LICENSEE:

DUKE POWER COMPANY LLC (DUKE)

FACILITY:

OCONEE NUCLEAR STATION, UNITS 1, 2, AND 3 (OCONEE)

SUBJECT:

SUMMARY

OF JANUARY 24, 2008, MEETING TO DISCUSS OCTOBER 16, 2007, LICENSE AMENDMENT REQUEST (LAR) THAT PROPOSES MODIFICATONS TO MITIGATE WATER HAMMERS (TAC NOS. MD7000, MD7001, AND MD7002)

On January 24, 2008, the U.S. Nuclear Regulatory Commission (NRC) staff met with Duke (the licensee) to discuss the October 16, 2008, LAR that proposes modifications to mitigate water hammer. The October 16, 2008, LAR is available in the Agencywide Documents Access and Management System (ADAMS) under accession number ML072920449. The handouts provided by the licensee during the meeting are available under ADAMS accession number ML080250274. Enclosed is a list of the attendees.

The licensee discussed its proposed modification that will install check valves in the low-pressure service water (LPSW) supply header and automatic pneumatic discharge isolation valves, controllable vacuum breaker valves, and associated circuitry in the LPSW return header to isolate engineered safeguards portions of the LPSW system. The modification is intended to eliminate water hammers. The licensee also discussed proposed changes to the Technical Specifications associated with the modification.

The licensee stated that it intends to implement the modification on Unit 2 during the fall 2008 refueling outage, and requested that the amendments be issued by October 2008. The NRC staff stated that it could support that schedule.

/RA/

Leonard N. Olshan, Project Manager Plant Licensing Branch II-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket Nos. 50-269, 50-270, and 50-287

Enclosure:

List of Attendees cc w/encl: See next page Distribution:

PUBLIC S. Mazumdar LPL2-1 R/F K. Scales RidsNrrDorlLpl2-1 (MWong)

E. Smith RidsNrrPMLOlshan (hard copy)

M. Cox, EDO Rgn II RidsNrrLAMOBrien (hard copy)

RidsRgn2MailCenter (JMoorman)

RidsOgcRp RidsAcrsAncwMailCenter T. Liu, NRR Accession Number: ML080280212 OFFICE NRR/LPL2-1/PM NRR/LPL2-1/LA NRR/LPL2-1/BC (A)

NAME LOlshan:nc MOBrien MWong DATE 01 / 31 /08 01 / 30 /08 01 / 31 /08 OFFICIAL RECORD COPY

Enclosure MEETING ATTENDEES FROM JANUARY 24, 2008, MEETING WITH DUKE POWER COMPANY LLC (DUKE)

TO DISCUSS THE OCTOBER 16, 2007, LICENSE AMENDMENT REQUEST THAT PROPOSES MODIFICATIONS TO MITIGATE WATER HAMMERS NRC DUKE S. Mazumdar T. Glenn K. Scales H. Harling E. Smith P. Earnhardt L. Olshan R. Gambrell V. Bowman E. Burchfield T. Brown

Enclosure Oconee Nuclear Station, Units 1, 2, and 3 cc:

Mr. Bruce H. Hamilton Vice President, Oconee Site Duke Power Company LLC 7800 Rochester Highway Seneca, SC 29672 Ms. Lisa F. Vaughn Associate General Counsel and Managing Attorney Duke Energy Carolinas, LLC 526 South Church Street - EC07H Charlotte, North Carolina 28202 Manager, LIS NUS Corporation 2650 McCormick Dr., 3rd Floor Clearwater, FL 34619-1035 Senior Resident Inspector U.S. Nuclear Regulatory Commission 7812B Rochester Highway Seneca, SC 29672 Mr. Henry Porter, Director Division of Radioactive Waste Management Bureau of Land and Waste Management Dept. of Health and Env. Control 2600 Bull St.

Columbia, SC 29201-1708 Mr. Michael A. Schoppman Framatome ANP 1911 North Ft. Myer Dr.

Suite 705 Rosslyn, VA 22209 Mr. B. G. Davenport Regulatory Compliance Manager Oconee Nuclear Site Duke Energy Corporation ON03RC 7800 Rochester Highway Seneca, SC 29672 Mr. Leonard G. Green Assistant Attorney General NC Department of Justice P.O. Box 629 Raleigh, NC 27602 Mr. R. L. Gill, Jr.

Manager - Nuclear Regulatory Issues and Industry Affairs Duke Power Company LLC 526 S. Church St.

Mail Stop EC05P Charlotte, NC 28202 Division of Radiation Protection NC Dept of Environment, Health, & Natural Resources 3825 Barrett Dr.

Raleigh, NC 27609-7721 Mr. Peter R. Harden, IV VP-Customer Relations and Sales Westinghouse Electric Company 6000 Fairview Road 12th Floor Charlotte, NC 28210 Mr. Henry Barron Group Vice President, Nuclear Generation and Chief Nuclear Officer P.O. Box 1006-EC07H Charlotte, NC 28201-1006 Mr. Charles Brinkman Director, Washington Operations Westinghouse Electric Company 12300 Twinbrook Parkway, Suite 330 Rockville, MD 20852 Ms. Kathryn B. Nolan Senior Counsel Duke Energy Carolinas, LLC 526 South Church Street - EC07H Charlotte, NC 28202