Letter Sequence Meeting |
---|
TAC:MD6792, Addition of New Tech Spec on RCS Boron Limits and Revisions to Tech Spec 3.3.1 to Address Rwfs (Open) TAC:MD7252, Eliminate Second Completion Times Limiting Time from Discovery of Failure to Meet an LCO (Approved, Closed) |
|
MONTHYEARML0703900572007-02-21021 February 2007 BVPS Doc Table M Project stage: Other ML0725504882007-08-30030 August 2007 10 CFR 50.55a Request: Proposed Alternative to ASME Section Xi Requirements for Replacement of Class 3 Buried Piping Project stage: Request ULNRC-05445, One-Time Completion Time Extension for Essential Service Water (ESW) System2007-10-31031 October 2007 One-Time Completion Time Extension for Essential Service Water (ESW) System Project stage: Request ML0800400232008-01-0808 January 2008 Forthcoming Meeting with Union Electric Company on the Callaway Plant Relief and Amendment Requests Dated August 3 and October 31, 2007. (Tac No. MD6792 and MD7252) Project stage: Meeting ML0802504052008-01-23023 January 2008 Licensee Handout for Meeting with Union Electric Company on the Callaway Plant Relief Request I3R-10 to Use Plastic Pipe in the Safety-Related Essential Service Water (ESW) System Project stage: Meeting ML0803802882008-02-0707 February 2008 Preliminary Request for Additional Information Project stage: RAI ULNRC-05476, One-Time Completion Time Extension for Essential Service Water (ESW) System2008-02-21021 February 2008 One-Time Completion Time Extension for Essential Service Water (ESW) System Project stage: Other ML0803806472008-02-29029 February 2008 Summary of Meeting with Union Electric Company Callaway Plant, Unit 1, 8/30/2007 Relief Request and 10/31/2007 License Amendment Request Applications Related to Replacement of Essential Service Water Piping (Tac No. MD6792 and MD7252) Project stage: Meeting ULNRC-05482, Response to Questions Received on February 7, 2008 Regarding Amendment to Revise Technical Specifications for Essential Service Water2008-03-0707 March 2008 Response to Questions Received on February 7, 2008 Regarding Amendment to Revise Technical Specifications for Essential Service Water Project stage: Other ML0808800122008-03-31031 March 2008 Request for Additional Information Related to LAR to Revise TS 3.7.8, Essential Service Water System, and TS 3.8.1, AC Sources - Operating, for One-time Completion Time Extension Re Underground Piping Project stage: RAI ULNRC-05434, CFR50.55a Request: Proposed Alternative to ASME Section X1 Requirements for Replacement of Class 3 Buried Piping2008-04-17017 April 2008 CFR50.55a Request: Proposed Alternative to ASME Section X1 Requirements for Replacement of Class 3 Buried Piping Project stage: Request ULNRC-05500, Response to Request for Additional Information One-Time Completion Time Extension for Essential Service Water (ESW) System2008-05-0606 May 2008 Response to Request for Additional Information One-Time Completion Time Extension for Essential Service Water (ESW) System Project stage: Response to RAI ML0815800112008-06-10010 June 2008 Request for Additional Information, Relief Request No. 13R-10 and License Amendment Request to Revise TS 3.7.8, Essential Service Water System, and TS 3.8.1, AC Sources - Operating, for One-time CT Extension Underground Piping Project stage: RAI ML0817506442008-06-24024 June 2008 Forthcoming Meeting with Union Electric Company on the Callaway Plant to Discuss the Licensee'S Responses to NRC Request for Additional Information Relief and License Amendment Requests Project stage: RAI ULNRC-05517, CFR50.55a Request: Proposed Alternative to ASME Section XI Requirements for Replacement of Class 3 Buried Piping2008-07-10010 July 2008 CFR50.55a Request: Proposed Alternative to ASME Section XI Requirements for Replacement of Class 3 Buried Piping Project stage: Request ULNRC-05520, One-Time Completion Time Extension for Essential Service Water (ESW) System, (OL1281)2008-07-10010 July 2008 One-Time Completion Time Extension for Essential Service Water (ESW) System, (OL1281) Project stage: Other ULNRC-05529, CFR50.55a Request: Proposed Alternative to ASME Section XI Requirements for Replacement of Class 3 Buried Piping2008-07-24024 July 2008 CFR50.55a Request: Proposed Alternative to ASME Section XI Requirements for Replacement of Class 3 Buried Piping Project stage: Request ULNRC-05534, One-Time Completion Time Extension for Essential Service Water (ESW) System2008-08-13013 August 2008 One-Time Completion Time Extension for Essential Service Water (ESW) System Project stage: Other ML0826307992008-09-0505 September 2008 Calculation 2007-13241, Rev. 1, Minimum Wall Thickness for ESW Buried Hdpe Piping. Project stage: Other ML0826308002008-09-12012 September 2008 Calculation 2007-16760, Rev. 0, Buried Hdpe Piping Stress Analysis. Project stage: Other ULNRC-05542, Transmittal of Callaway, Unit 1, Additional Information Regarding 10CFR50.55a Request: Proposed Alternative to ASME Section XI Requirements for Replacement of Class 3 Buried Piping2008-09-15015 September 2008 Transmittal of Callaway, Unit 1, Additional Information Regarding 10CFR50.55a Request: Proposed Alternative to ASME Section XI Requirements for Replacement of Class 3 Buried Piping Project stage: Request ULNRC-05553, Follow-up Information Regarding 10CFR50.55a Request: Proposed Alternative to ASME Section XI Requirements for Replacement of Class 3 Buried Piping (TAC No. MD67920)2008-10-0909 October 2008 Follow-up Information Regarding 10CFR50.55a Request: Proposed Alternative to ASME Section XI Requirements for Replacement of Class 3 Buried Piping (TAC No. MD67920) Project stage: Request ML0828106432008-10-31031 October 2008 Issuance of Amendment No. 186, Revise TS 3.7.8, Essential Service Water System, and TS 3.8.1, AC Sources - Operating, for One-time Completion Time Extension Re Underground Piping Project stage: Approval ML0826400072008-10-31031 October 2008 Relief Request I3R-10 for Use of Polyethylene Pipe in Lieu of Carbon Steel Pipe in Buried Essential Service Water Piping System Project stage: Acceptance Review ML0831001342008-11-0606 November 2008 Correction to Amendment No. 186 Approving One-Time Extension of Completion Time for Inoperable Essential Service Water System and Emergency Diesel Generators Project stage: Other ML0831002882008-11-0707 November 2008 Relief Request 13R-10 Approved on October 31, 2008, for Third 10-Year Inservice Inspection Interval for Use of Polyethylene Pipe in Lieu of Carbon Steel Pipe in Buried Essential Service Water Piping System Project stage: Acceptance Review ULNRC-05563, One-Time Completion Time Extension for Essential Service Water System2008-12-0101 December 2008 One-Time Completion Time Extension for Essential Service Water System Project stage: Other ML0834503272008-12-19019 December 2008 Summary of Meeting with Representatives of Union Electric Company, Licensee for Callaway Plant, Unit 1 Second Round of Requests for Information, Extension of Completion Time for Essential Service Water Systems (TAC Nos. MD6792 & MD7252) Project stage: Meeting ULNRC-06115, CFR 50.55a Request: Proposed Alternative to ASME Section XI Alternative Technical Requirements for Class 3 Buried Piping2014-06-10010 June 2014 CFR 50.55a Request: Proposed Alternative to ASME Section XI Alternative Technical Requirements for Class 3 Buried Piping Project stage: Request 2008-02-07
[Table View] |
|
---|
Category:Meeting Notice
MONTHYEARML22242A1162022-08-30030 August 2022 Pre-Application Teleconference with Union Electric Company to Discuss Approval to Insert Framatome'S Gaia Fuel Assemblies in Its Core in Reload Quantities for the Callaway Plant, Unit No. 1 ML22168A0262022-06-17017 June 2022 Preapplication Teleconference with Union Electric Company to Discuss a Spent Fuel Pool License Amendment Request for Callaway Plant, Unit No. 1 PMNS20220467, Public Webinar to Discuss the Nuclear Regulatory Commission'S 2021 Annual Assessment of Safety Performance at Region IV Plants2022-05-0303 May 2022 Public Webinar to Discuss the Nuclear Regulatory Commission'S 2021 Annual Assessment of Safety Performance at Region IV Plants ML22045A9852022-02-14014 February 2022 Partially Closed Pre-Application Teleconference with Union Electric Company to Discuss Approval to Insert Framatome'S Gaia Fuel Assemblies in Its Core in Reload Quantities for the Callaway Plant, Unit No. 1 ML21265A2722021-09-22022 September 2021 Partially Closed Pre-Application Teleconference with Union Electric Company to Discuss Approval to Insert Framatome'S Gaia Fuel Assemblies in Its Core in Reload Quantities for the Callaway Plant, Unit No. 1 ML21211A6022021-07-28028 July 2021 Annual Assessment Meeting ML21195A3202021-07-14014 July 2021 Pre-Application Teleconference with Union Electric Company to Discuss a License Amendment Request to Revise the Emergency Plan for the Callaway Plant, Unit No. 1 ML21190A2812021-07-0909 July 2021 Notice of Public Webinar with Ameren Missouri to Discuss the Nuclear Regulatory Commission'S 2020 Annual Assessment of Callaway Plant PMNS20210942, Public Webinar with Ameren Missouri to Discuss the Nuclear Regulatory Commissions 2020 Annual Assessment of Callaway Plant2021-07-0909 July 2021 Public Webinar with Ameren Missouri to Discuss the Nuclear Regulatory Commissions 2020 Annual Assessment of Callaway Plant ML21130A6842021-05-10010 May 2021 Partially Closed Pre-Application Teleconference with Union Electric Company to Discuss Approval to Insert Framatome'S Gaia Fuel Assemblies in Their Core in Reload Quantities for the Callaway Plant, Unit No. 1 ML21125A4262021-05-0505 May 2021 Partially Closed Pre-Application Teleconference with Union Electric Company to Discuss Approval to Insert Framatome'S Gaia Fuel Assemblies in Their Core in Reload Quantities for the Callaway Plant, Unit No. 1 ML21074A2752021-03-15015 March 2021 Pre-Application Teleconference with Union Electric Company Regarding Callaway Plant Unit No. 1 to Discuss an Alternative Source Term License Amendment Request ML21063A5132021-03-0404 March 2021 Pre-Application Teleconference with Union Electric Company Regarding Callaway Plant Unit No. 1 to Discuss an Alternative Source Term License Amendment Request ML20170B1872020-06-19019 June 2020 Public Webinar to Discuss the Nrc'S Assessment of Safety Performance at Region IV Plants for 2019 ML20353A3592020-03-26026 March 2020 Enclosure 3 - 2020 Proxy Statement of Ameren Corporation ML14066A4972014-03-0707 March 2014 03/19/2014 Notice of Forthcoming Category 3 Public Meeting to Discuss the Draft Supplement 51 to the Generic Environmental Impact Statement for License Renewal of Nuclear Plants (NUREG-1437) for Callaway, Unit 1, Issued in February 2014 ML14035A3032014-02-0404 February 2014 02/20/2014 Notice of Forthcoming Category 1 Meeting with Union Electric Co. (Ameren Missouri) and Westinghouse to Discuss License Renewal for the Callaway Plant Unit 1 ML14029A6372014-01-29029 January 2014 02/19/2014 Notice of Forthcoming Category Public Meeting with Union Electric Co. (Ameren Missouri) to Discuss Unresolved Technical Issues Associated with Materials Reliability Program (MRP)-227-A Re Callaway, Unit 1 Re License Renewal ML13059A8002013-03-11011 March 2013 Summary of Telephone Call Held on 11/5/12, Between NRC and Union Electric Company, Regarding Request for Clarification of Responses to the SAMA RAI Concerning Callaway Plant, Unit 1, LRA ML12363A4612012-12-28028 December 2012 01/17/2013 Meeting Notice with NRC to Discuss the Results of the Callaway Nuclear Plant License Renewal Inspection Conducted in September 2012, with Interested Members of the Public ML12298A4282012-10-26026 October 2012 Notice of Preapplication Meeting with Union Electric Company to Discuss Callaway Plant, Unit 1, License Amendment Request to Change Licensing Basis and Analysis of Integrated Head Assembly Consistent with Regulatory Guide 1.61 Revision 1 ML12227A3472012-08-14014 August 2012 8/29/2012 Notice of Preapplication Meeting with Union Electric Company to Discuss Request for New Technical Specification Related to Class 1E Electrical Equipment Air Conditioning System at Callaway Plant, Unit 1 ML12227A3492012-08-14014 August 2012 8/29/2012 Notice of Preapplication Meeting with Union Electric Company to Discuss Request to Revise Technical Specification 3.7.9, Ultimate Heat Sink SR 3.7.9.1 and 3.7.9.2 at Callaway Plant, Unit 1 ML12041A4792012-02-24024 February 2012 03/14/2012-Notice of Forthcoming Meeting to Discuss the License Renewal Process and Environmental Scoping for Callaway Plant, Unit 1 ML1200300872011-12-29029 December 2011 Forthcoming Meeting with Petitioner Requesting Action Under 10 CFR 2.206 Regarding Blocking P-4/Low Tavg Feedwater Isolation Signal at Callaway Plant, Unit 1 ML1136304032011-12-29029 December 2011 Correction Notice of Forthcoming Meeting with Petitioner Requesting Action Under 10 CFR 2.206 ML1136300262011-12-29029 December 2011 Notice of Forthcoming Meeting with Petitioner Requesting Action Under 10 CFR 2.206 Regarding Blocking P-4/LO Tavg Feedwater Isolation Signal at Callaway Plant Unit 1 ML11192A2362011-07-12012 July 2011 Notice of Closed Meeting with Callaway to Discuss Lessons Learned from the Recent Triennial Force-On-Force Exercise at the Callaway Nuclear Power Plant ML1113202252011-05-12012 May 2011 Notice of Preapplication Meeting with Union Electric Company to Discuss Callaway Plant, Unit 1's Amendment Request to Adopt Risk-informed, Performance-Based Alternative Described in National Fire Protection Association Standard (NFPA) 805 ML1109501212011-04-0505 April 2011 Notice of Meeting to Discuss NRC Reactor Oversight Process Annual Assessment of Callaway Plant ML1101204702011-01-12012 January 2011 Notice of Meeting with Union Electric Company to Discuss Licensee'S Planned Responses to Staff Requests for Additional Information Callaway Plant'S Request to Revise TS 3.3.2, ESFAS Instrumentation Functions ML1030202792010-11-0505 November 2010 Notice of Meeting with Union Electric Company to Discuss Licensee'S Planned Responses to Staff Requests for Additional Information Related to Callaway Plant'S Request to Revise TS 3.3.2, ESFAS Instrumentation Functions ML1011003572010-04-19019 April 2010 Annual Assessment Public Meeting with Amerenue ML1007100312010-03-12012 March 2010 Notice of Forthcoming Conference Call with Union Electric Company to Discuss Proposed Application for Relocation of Surveillance Frequencies from Callaway Plant Technical Specifications (Risk-Managed TS Initiative 5b) ML0929300152009-10-20020 October 2009 Revised Notice of Meeting with Union Electric Company and Wolf Creek Nuclear Operating Company to Discuss NRC Requests for Additional Information on Generic Letter 2004-02 ML0929403662009-10-20020 October 2009 Notice of Category 1 Meeting to Discuss the Significance, Cause, and Corrective Action Associated with an Apparent Violation Involving the Inoperability of the Turbine Driven Auxiliary Feedwater Pump ML0928003162009-10-16016 October 2009 Notice of Meeting with Union Electric Company and Wolf Creek Nuclear Operating Company to Discuss NRC Requests for Additional Information on Generic Letter 2004-02 Sent 7/31/0209 and 8/27/2009, Respectively ML0924605592009-09-0404 September 2009 Notice of Meeting with Union Electric Company to Discuss a Proposed Risk Informed Change to Callaway, Unit 1, Technical Specifications ML0920306202009-07-31031 July 2009 Notice of Forthcoming Conference Call with Union Electric Company and Wolf Creek Nuclear Operating Company Re Draft Requests for Additional Information on Generic Letter 2004-02 for Callaway Plant and Wolf Creek Creek Generating Station ML0912402762009-05-0404 May 2009 Notice of Annual Assessment Public Meeting with Amerenue to Present and Discuss Performance Results of the Callaway Plant for the Period of January 1 Through December 31, 2008 ML0906401852009-03-0505 March 2009 Notice of Meeting with Amerenue to Discuss Various Engineering Related Topics at Callaway Plant ML0834503272008-12-19019 December 2008 Summary of Meeting with Representatives of Union Electric Company, Licensee for Callaway Plant, Unit 1 Second Round of Requests for Information, Extension of Completion Time for Essential Service Water Systems (TAC Nos. MD6792 & MD7252) ML0817506442008-06-24024 June 2008 Forthcoming Meeting with Union Electric Company on the Callaway Plant to Discuss the Licensee'S Responses to NRC Request for Additional Information Relief and License Amendment Requests ML0814001252008-05-0909 May 2008 Notice of Meeting with Callaway Plant to Discuss the Results of Inspections and Performance Indicators ML0812305882008-05-0202 May 2008 End-of-cycle Public Meeting with Amerenue to Present and Discuss Performance Results of the Callaway Plant for the Period of January 1 Though December 31, 2007 ML0800400232008-01-0808 January 2008 Forthcoming Meeting with Union Electric Company on the Callaway Plant Relief and Amendment Requests Dated August 3 and October 31, 2007. (Tac No. MD6792 and MD7252) ML0726404022007-09-21021 September 2007 Notice of Meeting with Union Electric Company to Discuss Various Topics Related to Callaway ML0713300022007-05-0404 May 2007 Notice of Meeting to Discuss Results of Annual Assessment Associated with the 2006 Inspections and Performance Indicators for Callaway Plant ML0712100702007-04-30030 April 2007 Notice of Meeting with Union Electric Company/Ameren Ue to Describe the Reactor Oversight Process, Discuss Licensee Performance at the Callaway Plant During Calendar Year 2006, and Discuss Topics of Potential Interest to the Public ML0617202222006-04-0707 April 2006 Individual Invitation Letter to Public Annual Performance Assessment Meeting Regarding Callaway Plant 2022-08-30
[Table view] |
Text
January 8, 2008 MEMORANDUM TO: Thomas G. Hiltz, Chief Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM: Jack Donohew, Senior Project Manager /RA/
Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
SUBJECT:
FORTHCOMING MEETING WITH UNION ELECTRIC COMPANY ON THE CALLAWAY PLANT (TAC NOS. MD6792 AND MD7252)
DATE & TIME: Wednesday, January 23, 2008 10:00 a.m. - 12:00 noon LOCATION: U.S. Nuclear Regulatory Commission Executive Boulevard Building 6003 Executive Boulevard, Room 2-B-18 Rockville, Maryland 20852 PURPOSE: The licensee and NRC staff will discuss the licensees relief and license amendment requests dated August 3 and October 31, 2007, respectively, to replace Essential Service Water System piping by plastic pipe.
CATEGORY:
- This is a Category 1 Meeting. The public is invited to observe this meeting and will have one or more opportunities to communicate with the NRC after the business portion, but before the meeting is adjourned.
PARTICIPANTS: NRC Participants are in the Office of Nuclear Reactor Regulation.
NRC UTILITY A. Howe B. Yates T. Chan M. Brandes D. Naujock S. Abel J. Donohew, et al. S. Maglio, et. al.
Docket No. 50-483
Enclosure:
Agenda cc w/encl: See next page MEETING CONTACTS: Jack Donohew, NRR Alan Wang, NRR 301-415-1307 301-415-1445 jnd@nrc.gov abw@nrc.gov
- Commission's Policy Statement on Enhancing Public Participation in NRC Meetings," 67 FR 36920, May 28, 2002.
January 8, 2008 MEMORANDUM TO: Thomas G. Hiltz, Chief Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation FROM: Jack Donohew, Senior Project Manager /RA/
Plant Licensing Branch IV Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation
SUBJECT:
FORTHCOMING MEETING WITH UNION ELECTRIC COMPANY ON THE CALLAWAY PLANT (TAC NOS. MD6792 AND MD7252)
DATE & TIME: Wednesday, January 23, 2008 10:00 a.m. - 12:00 noon LOCATION: U.S. Nuclear Regulatory Commission Executive Boulevard Building 6003 Executive Boulevard, Room 2-B-18 Rockville, Maryland 20852 PURPOSE: The licensee and NRC staff will discuss the licensees relief and license amendment requests dated August 3 and October 31, 2007, respectively, to replace Essential Service Water System piping by plastic pipe.
CATEGORY:
- This is a Category 1 Meeting. The public is invited to observe this meeting and will have one or more opportunities to communicate with the NRC after the business portion, but before the meeting is adjourned.
PARTICIPANTS: NRC Participants are in the Office of Nuclear Reactor Regulation.
NRC UTILITY A. Howe B. Yates T. Chan M. Brandes D. Naujock S. Abel J. Donohew, et al. S. Maglio, et. al.
Docket No. 50-483
Enclosure:
Agenda cc w/encl: See next page MEETING CONTACTS: Jack Donohew, NRR Alan Wang, NRR 301-415-1307 301-415-1445 jnd@nrc.gov abw@nrc.gov
- Commission's Policy Statement on Enhancing Public Participation in NRC Meetings," 67 FR 36920, May 28, 2002.
ACCESSION NO.: ML0800400023 OFFICE LPLIV/PM LPLIV/LA LPLIV/BC NAME JDonohew JBurkhardt THiltz DATE OFFICIAL RECORD COPY
FORTHCOMING MEETING WITH UNION ELECTRIC COMPANY ON THE CALLAWAY PLANT (TAC NOS. MD6792 AND MD7252) ON JANUARY 23, 2008 Dated: January 8, 2008 DISTRIBUTION:
Hard Copy JDonohew E-mail RidsNrrAdro(BBoger)
RidsNrrDorl(CHaney/JLubinski)
RidsNrrDorlLpl4(THiltz)
RidsNrrPMJDonohew RidsNrrLAJBurkhardt RidsNrrAdes RidsOgcMailCenter RidsOpaMail RidsAcrsAcnwMailCenter RidsRgn4MailCenter TLiu, NRR TChan, NRR DNaujock, NRR MRubin, NRR AHowe, NRR DDumbacher, RIV DPelton, EDO RIV VDricks, OPA RIV PMNS Meeting Announcement Coordinator
Callaway Plant, Unit 1 (November 2007) cc:
Mr. Charles D. Naslund Mr. H. Floyd Gilzow Senior Vice President & Chief Nuclear Officer Deputy Director for Policy Union Electric Company Department of Natural Resources Post Office Box 620 P.O. Box 176 Fulton, MO 65251 Jefferson City, MO 65102-0176 John ONeill, Esq. Mr. Rick A. Muench, President and CEO Pillsbury Winthrop Shaw Pittman LLP Wolf Creek Nuclear Operating Corporation 2300 N. Street, N.W. P.O. Box 411 Washington, D.C. 20037 Burlington, KA 66839 Mr. Tom Elwood, Supervising Engineer Certrec Corporation Regulatory Affairs and Licensing 4200 South Hulen, Suite 422 AmerenUE Fort Worth, TX 76109 P.O. Box 620 Fulton, MO 65251 Technical Services Branch Chief FEMA Region VII Mr. Les H. Kanuckel, Manager 2323 Grand Boulevard, Suite 900 Quality Assurance Kansas City, MO 64108-2670 AmerenUE P.O. Box 620 Kathleen Logan Smith, Executive Director and Fulton, MO 65251 Kay Drey, Representative, Board of Directors Missouri Coalition for the Environment Mr. Luke Graessle, Manager 6267 Delmar Blvd., Suite 2E Regulatory Affairs St. Louis, City, MO 63130 AmerenUE P.O. Box 620 Mr. Lee Fritz, Presiding Commissioner Fulton, MO 65251 Callaway County Courthouse 10 East Fifth Street Mr. Scott Maglio Fulton, MO 65251 Assistant Manager, Regulatory Affairs AmerenUE Mr. Keith G. Henke, Planner III P.O. Box 620 Division of Community and Public Health Fulton, MO 65251 Office of Emergency Coordination Missouri Department of Health and U.S. Nuclear Regulatory Commission Senior Services Resident Inspector Office 930 Wildwood Drive 8201 NRC Road P.O. Box 570 Steedman, MO 65077-1302 Jefferson City, MO 65102 Missouri Public Service Commission Mr. Scott Clardy, Director Governor Office Building Section for Environmental Public Health 200 Madison Street Missouri Department of Health and P.O. Box 360 Senior Services Jefferson City, MO 65102-0360 930 Wildwood Drive P.O. Box 570 Regional Administrator, Region IV Jefferson City, MO 65102 U.S. Nuclear Regulatory Commission 611 Ryan Plaza Drive, Suite 400 Director, Missouri State Emergency Arlington, TX 76011-4005 Management Agency P.O. Box 116 Jefferson City, MO 65102-0116
AGENDA MEETING WITH UNION ELECTRIC COMPANY RELATED TO REQUEST TO REPLACE ESSENTIAL SERVICE WATER PIPING WITH PLASTIC PIPE RELIEF REQUEST AND LICENSE AMENDMENT REQUEST JANUARY 23, 2008
! Introductions
! Licensee Presentation This addresses the basis for the licensees relief request dated August 3, 2007, and license amendment request dated October 31, 2007 (Agencywide Documents Access and Management System Accession Nos. ML072550488 and ML073100488, respectively). This will explain the licensees proposal to replace underground Essential Service Water piping with high density polyethylene (HDPE) pipe.
! NRC Staff Presentation The NRC staff will present the questions it has developed based on its review of the two above requests submitted by the licensee.
! Comments, Questions, and Discussion
! End of Meeting
! Public Comments