January 8, 2008 Mr. John T. Carlin Vice President R.E. Ginna Nuclear Power Plant R.E. Ginna Nuclear Power Plant, LLC 1503 Lake Road Ontario, NY 14519
SUBJECT:
REQUEST FOR ADDITIONAL INFORMATION RE: CONTROL ROOM HABITABILITY - R.E. GINNA NUCLEAR POWER PLANT (TAC NO. MD6679)
Dear Mr. Carlin:
By letter dated August 16, 2007, R.E. Ginna Nuclear Power Plant, LLC requested a license amendment to Renewed Operating License No. DPR-18 to modify Technical Specification requirements for the control room emergency ventilation system in accordance with Technical Specification Task Force (TSTF) TSTF-448, Control Room Habitability, Revision 3, for the R.E. Ginna Nuclear Power Plant.
The Nuclear Regulatory Commission (NRC) staff has reviewed the information provided and has determined that additional information is needed to complete its review. Enclosed is the NRC staffs request for additional information (RAI). As discussed with your staff, we understand that you intend to respond to this RAI within 60 days of receipt of this letter.
Please contact me at 301-415-1364 if you have any questions.
Sincerely,
/RA/
Douglas V. Pickett, Senior Project Manager Plant Licensing Branch I-1 Division of Operating Reactor Licensing Office of Nuclear Reactor Regulation Docket No. 50-244
Enclosure:
As stated cc w/encl: See next page
ML073620407 OFFICE PM/LPL1-1 LA:LPL1-1 BC/SCVB BC/LPL1-1 NAME DPickett SLittle RDennig MKowal DATE 1 /03/ 08 1 /03/ 08 1 /08/ 08 1 /08/ 08
R.E. Ginna Nuclear Power Plant cc:
Mr. Michael J. Wallace, President Constellation Energy Nuclear Group, LLC 750 East Pratt Street, 18th Floor Baltimore, MD 21202 Mr. John M. Heffley, Senior Vice President and Chief Nuclear Officer Constellation Energy Nuclear Generation Group 111 Market Place Baltimore, MD 21202 Kenneth Kolaczyk, Sr. Resident Inspector R.E. Ginna Nuclear Power Plant U.S. Nuclear Regulatory Commission 1503 Lake Road Ontario, NY 14519 Regional Administrator, Region I U.S. Nuclear Regulatory Commission 475 Allendale Road King of Prussia, PA 19406 Mr. John P. Spath New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. Paul Tonko President and CEO New York State Energy, Research, and Development Authority 17 Columbia Circle Albany, NY 12203-6399 Mr. Carey W. Fleming, Esquire Senior Counsel - Nuclear Generation Constellation Energy Nuclear Group, LLC 750 East Pratt Street, 17th Floor Baltimore, MD 21202 Mr. Charles Donaldson, Esquire Assistant Attorney General New York Department of Law 120 Broadway New York, NY 10271 Mr. George Bastedo, Director Wayne County Emergency Management Office Wayne County Emergency Operations Center 7336 Route 31 Lyons, NY 14489 Ms. Mary Louise Meisenzahl Administrator, Monroe County Office of Emergency Preparedness 1190 Scottsville Road, Suite 200 Rochester, NY 14624 Mr. Paul Eddy New York State Department of Public Service 3 Empire State Plaza, 10th Floor Albany, NY 12223 Mr. Brian R. Weaver Director, Licensing R.E. Ginna Nuclear Power Plant 1503 Lake Road Ontario, NY 14519 Mr. Louis S. Larragoite Manager - Nuclear Licensing Constellation Energy Nuclear Generation Group 111 Market Place, 2nd Floor Baltimore, MD 21202
Enclosure REQUEST FOR ADDITIONAL INFORMATION CONTROL ROOM HABITABILITY TSTF-448 R.E. GINNA NUCLEAR POWER PLANT DOCKET NO. 50-244 Technical Specification Task Force (TSTF) TSTF-448, Revision 3, Control Room Habitability, was developed for plants with pressurized control room envelopes (CREs). The R.E. Ginna Nuclear Power Plant has a non-pressurized CRE. Note that the programs and manuals section of the standard technical specifications (STS), as modified by TSTF-448, Revision 3, paragraph (d) of Section 5.5.18, Control Room Envelope Habitability Program, specifies a differential pressure (dp) test to be conducted between performances of inleakage testing for the purpose of providing input to a periodic assessment of the CRE boundary. The NRC staff recognizes that non-pressurized CREs may not be able to conduct a dp test. However, the staff believes that all plants requesting the adoption of TSTF-448 should include a method to collect data that will serve as input to a periodic assessment of the CRE boundary. This position is supported by the technical analysis section of TSTF-448, Revision 3, on page 8 where an explanation of the basis for paragraph (d) is provided. Consequently, the NRC staff is requesting that you provide a method to collect data, and an explanation of how you intend to use it to periodically assess the integrity of your CRE boundary. The method should, to the extent practicable, provide information that can be used in a manner similar to the manner in which the information is to be used that is requested by paragraph (d) of Section 5.5.18 of the programs and manuals section of the STS as modified by TSTF-448, Revision 3.