Text

W'SLF CREEK

'NUCLEAR OPERATING CORPORATION Kevin J. Moles Manager Regulatory Affairs October 18, 2007 RA 07-0101 U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, DC 20555

Subject:

Docket No. 50-482: Emergency Response Data System (ERDS)

Data Point Library Changes Gentlemen:

In accordance with 10 CFR 50 Appendix E. VI. 3.a., this letter transmits changes to Wolf Creek Generating Station's (WCGS) Data Point Library (DPL). The attachment describes the specific changes to the affected data points. The enclosure contains the replacement pages to update the WCGS DPL.

These changes were not submitted within 30 days after the changes were completed. This has been entered into the Wolf Creek corrective action program.

This letter contains no commitments. If you have any questions concerning this matter, please contact me at (620) 364-4126, or Diane Hooper at (620) 364-4041.

Sincerely, Kevin J. Moles KJM/rlt Attachment Enclosure cc:

E. E. Collins (NRC), w/a, w/e J. N. Donohew (NRC), w/a, w/e V. G. Gaddy (NRC), w/a, w/e Senior Resident Inspector (NRC), w/a, w/e P.O. Box 411 / Burlington, KS 66839 Phone: (620) 364-8831 An Equal Opportunity Employer M/F/HC/VET

Attachment to RA 07-0101 Page 1 of 1 The following data points are changed as indicated:

BBU0004 Removed Safety Parameter Display System (SPDS) from the description as it is no longer an SPDS point.

BBU0014 Removed Safety Parameter Display System (SPDS) from the description as it is no longer an SPDS point.

BNUO001 Removed Safety Parameter Display System (SPDS) from the description as it is no longer an SPDS point.

GHN0103 Description changed to RADWASTE VENT EFFLUENT LOW/MID/HIIGH to be more descriptive of point function.

GNUO001 Removed Safety Parameter Display System (SPDS) from the description as it is no longer an SPDS point.

GSU0001 Hi alarm value changed to 2.75.

GTN0213 Description changed to UNIT VENT LOW/MID/HIGH VALUE to be more descriptive of point function.

GTU0001 Removed Safety Parameter Display System (SPDS) from the description as it is no longer an SPDS point.

RDA0001 Description changed to 10 METER WIND DIRECTION #1 and maximum instrument range changed to 360.

RDS0001 Description changed to 10M WIND SPEED #1.

RDT0004 Description changed to 60M-10M TEMP DIFF C #1.

RJU0577 Description changed to 5 HOTTEST T/C AVERAGE. This is no longer an SPDS point.

SEU0001 Maximum instrument range is 240. Removed Safety Parameter Display System (SPDS) from the description as it is no longer an SPDS point.

SEU0002 Removed Safety Parameter Display System (SPDS) from the description as it is no longer an SPDS point.

Enclosure to RA 07-0101 Replacement pages to update the Wolf Creek Generating Station Data Point Library

WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)

Reactor Unit: (3)

Data Feeder: (10)

NRC ERDS Parameter: (12)

Point ID: (12)

Plant Spec Point Desc: (40)

Generic/Cond Desc: (32)

Analog/Digital: (1)

Engr Units/Dig States: (12)

Engr Units Conversion: (40)

Minimum Instr Range: (10)

Maximum Instr Range: (10)

Zero Point

Reference:

(6)

Reference Point Notes: (40)

PROC or SENS: (1)

Number of Sensors: (3)

How Processed: (40)

Sensor Locations: (40)

Alarm/Trip Set Points: (40)

NI Detector Power Supply Cut-off Power Level: (15)

NI Detector Power Supply Turn-on Power Level: (15)

Instrument Failure Mode: (30)

Temperature Compensation For DP Transmitters: (1)

Level Reference Leg: (3)

Unique System, Desc: (100) 8/30/2007 WC1 N/A RCS PRESSURE BBU0004 NORM RCS PRESS AVERAGE RCS PRESSURE A

PSIG N/A 0

3000 N/A N/A P

2 AVERAGE SEAL TABLE N/A N/A N/A LOW=LOP N/A N/A RCS WR PRESS XMITRS:

BBPT0405 BBPT0403 COMPUTER ALARMS MODE HIHI HI FP 2335 2300 LP 2335 2300 HS 2335 2300 HC 2335 2300 LO 1900 1900 1900 1900 LOLO 1875 1875 1875 1875

WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)

Reactor Unit: (3)

Data Feeder: (10)

NRC ERDS Parameter: (12)

Point ID: (12)

Plant Spec Point Desc: (40)

Generic/Cond Desc: (32)

Analog/Digital: (1)

Engr Units/Dig States: (12)

Engr Units Conversion: (40)

Minimum Instr Range: (10)

Maximum Instr Range: (10)

Zero Point

Reference:

(6)

Reference Point Notes: (40)

PROC or SENS: (1)

Number of Sensors: (3)

How Processed: (40)

Sensor Locations: (40)

Alarm/Trip Set Points: (40)

NI Detector Power Supply Cut-off Power Level: (15)

NI Detector Power Supply Turn-on Power Level: (15)

Instrument Failure Mode: (30)

Temperature Compensation For DP Transmitters: (1)

Level Reference Leg: (3)

Unique System Desc: (100) 8/30/2007 WC1 N/A PRZR LEVEL BBU0014 PZR WATER LEVEL AVERAGE PRIMARY SYSTEM PZR LEVEL A

PCT N/A 0

100 SURGE N/A P

3 AVERAGE 2026 CTMT OUTSIDE PZR PENTHOUSE RX TRIP 92% HEATERS 17%

N/A N/A LOW=LOP; HIGH=REF LEG LOSS Y

WET PZR LEVEL XMITRS BBLT0459 BBLT0460 BBLT0461 ZERO PT REF 212" FROM THE BOT; 212"-468" IS 0-100% INDICATED COMPUTER ALARMS MODE HIHI HI LO FP

.92 88 22 LP 92 88 22 HS 92 88 22 HC 92 88 22 LOLO 17 17 17 17

WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)

Reactor Unit: (3)

Data Feeder: (10)

NRC ERDS Parameter: (12)

Point ID: (12)

Plant Spec Point Desc: (40)

Generic/Cond Desc: (32)

Analog/Digital: (1)

Engr Units/Dig States: (12)

Engr Units Conversion: (40)

Minimum Instr Range: (10)

Maximum Instr Range: (10)

Zero Point

Reference:

(6)

Reference Point Notes: (40)

PROC or SENS: (1)

Number of Sensors: (3)

How Processed: (40)

Sensor Locations: (40)

Alarm/Trip Set Points: (40)

NI Detector Power Supply Cut-off Power Level: (15)

NI Detector Power Supply Turn-on Power Level: (15)

Instrument Failure Mode: (30)

Temperature Compensation For DP Transmitters: (1.)

Level Reference Leg: (3)

Unique System Desc: (100) 8/30/2007 WC1 N/A BWST LVL AVG BNUO001 RSWT LEVEL AVERAGE N/A A

PCT N/A 0.0 100.0 TNKBOT N/A P

4 AVERAGE OUTSIDE AUX BLDG IN RWST PIT LOW @ 36% LOLO @ 11% SWAP TO RECIRC SUMP N/A N/A LOW=LOP N/A, N/A RWST LEVEL XMITRS BNLT0930 BNLT0931 BNLT0932 BNLT0933 ZERO PT REF IS 24" FROM TNKBOT COMPUTER ALARMS MODE HI LO FP 99.8 97 LP 99.8 97 HS 99.8 97 HC 99.8 97 CS 99.8 97 RF 99.8 97

WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)

Reactor Unit: (3)

Data Feeder: (10)

NRC ERDS Parameter: (12)

Point ID: (12)

Plant Spec Point Desc: (40)

Generic/Cond Desc: (32)

Analog/Digital: (1)

Engr Units/Dig States: (12)

Engr Units Conversion: (40)

Minimum Instr Range: (10)

Maximum Instr Range: (10)

Zero Point

Reference:

(6)

Reference Point Notes: (40)

PROC or SENS: (1)

Number of Sensors: (3)

How Processed: (40)

Sensor Locations: (40)

Alarm/Trip Set Points: (40)

NI Detector Power Supply Cut-off Power Level: (15)

NI Detector Power Supply Turn-on Power Level: (15)

Instrument Failure Mode: (30)

Temperature Compensation For DP Transmitters: (1)

Level Reference Leg: (3)

Unique System Desc: (100) 8/30/2007 WC1 N/A EFF GAS RAD GHN0103 RADWASTE VENT EFFLUENT LOW/MID/HIGH RADIOACTIVITY OF REL GASES A

UCI/S N/A

.1 E-6

.1 E6 N/A N/A S

1 THROUGH RMS SYSTEM RADWASTE BLDG EXHAUST N/A N/A N/A LOW/LOC=LOP N/A N/A RMS MONITOR (GHRE0010B)

CHANNEL GHN0103 REF USAR TABLE 11.5-4

WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)

Reactor Unit: (3)

Data Feeder: (10)

NRC ERDS Parameter: (12)

Point ID: (12)

Plant Spec Point Desc: (40)

Generic/Cond Desc: (32)

Analog/Digital: (1)

Engr Units/Dig States: (12)

Engr Units Conversion: (40)

Minimum instr Range: (10)

Maximum Instr Range: (10)

Zero Point

Reference:

(6)

Reference Point Notes: (40)

PROC or SENS: (1)

Number of Sensors: (3)

How Processed: (40)

Sensor Locations: (40)

Alarm/Trip Set Points: (40)

NI Detector Power Supply Cut-off Power Level: (15)

NI Detector Power Supply Turn-on Power Level: (15)

Instrument Failure Mode: (30)

Temperature Compensation For DP Transmitters: (1)

Level Reference Leg: (3)

Unique System Desc: (100) 8/30/2007 WC1 N/A CTMNT TEMP GNUO001 CONTAINMENT TEMP AVERAGE N/A A

DEGF N/A 0

400 N/A N/A P

4 AVERAGE 2068 CTMT NORTH, WEST, NE, & EAST N/A N/A N/A LOW=LOP N/A N/A CTMT COOLER TEMP RTDS GNTE0060 (A)

GNTE0061 (B)

GNTE0062 (C)

GNTE0063 (D)

COMPUTER ALARMS HI @ 120 DEG F ON ALL MODES.

WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)

Reactor Unit: (3)

Data Feeder: (10)

NRC ERDS Parameter: (12)

Point ID: (12)

Plant Spec Point Desc: (40)

Generic/Cond Desc: (32)

Analog/Digital: (1)

Engr Units/Dig States: (12)

Engr Units Conversion: (40)

Minimum Instr Range: (10)

Maximum Instr Range: (10)

Zero Point

Reference:

(6)

Reference Point Notes: (40)

PROC or SENS: (1)

Number of Sensors: (3)

How Processed: (40)

Sensor Locations: (40)

Alarm/Trip Set Points: (40)

NI Detector Power Supply Cut-off Power Level: (15)

NI Detector Power Supply Turn-on Power Level: (15)

Instrument Failure Mode: (30)

Temperature Compensation For DP Transmitters: (1)

Level Reference Leg: (3)

Unique System Desc: (100) 8/30/2007 WC1 N/A H2 CONG GSU0001 SPDS CNTMT HYDROGEN CONC. AVG N/A A

PCT N/A 0.0 10.0 N/A N/A P

2 AVERAGE 2076 CTMT WEST & NORTH 2012 CTMT SE &

NE 2.5 PCT ANNUNCIATOR, EACH ANALYZER N/A N/A LOW=LOP N/A N/A CTMT H2 ANALYZERS COMPUTER ALARMS MODE HI FP 2.75 LP HP HC CS RF 2.8 2.8 2.8 2.8 2.8

WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)

Reactor Unit: (3)

Data Feeder: (10)

NRC ERDS Parameter: (12)

Point ID: (12)

Plant Spec Point Desc: (40)

Generic/Cond Desc: (32)

Analog/Digital: (1)

Engr Units/Dig States: (12)

Engr Units Conversion: (40)

Minimum Instr Range: (10)

Maximum Instr Range: (10)

Zero Point

Reference:

(6)

Reference Point Notes: (40)

PROC or SENS: (1)

Number of Sensors: (3)

How Processed: (40)

Sensor Locations: (40)

Alarm/Trip Set Points: (40)

NI Detector Power Supply Cut-off Power Level: (15)

NI Detector Power Supply Turn-on Power Level: (15)

Instrument Failure Mode: (30)

Temperature Compensation For DP Transmitters: (1)

Level Reference Leg: (3)

Unique System Desc: (100) 8/30/2007 WC1 N/A EFF GAS RAD GTN0213 UNIT VENT LOW/MID/HIGH VALUE N/A A

UCI/S N/A

.1 E-6

.1E6 N/A N/A S

1 THROUGH RMS SYSTEM AUX BLDG DISCAHRGE OF UNIT VENT LINE N/A N/A N/A LOW/LOC=LOP N/A N/A RMS MONITOR GTRE21B REF USAR TABLE 11.5-4

WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)

Reactor Unit: (3)

Data Feeder: (10)

NRC ERDS Parameter: (12)

Point ID: (12)

Plant Spec Point Desc: (40)

Generic/Cond Desc: (32)

Analog/Digital: (1)

Engr Units/Dig States: (12)

Engr Units Conversion: (40)

Minimum Instr Range: (10)

Maximum Instr Range: (10)

Zero Point

Reference:

(6)

Reference Point Notes: (40)

PROC or SENS: (1)

Number of Sensors: (3)

How Processed: (40)

Sensor Locations: (40)

Alarm/Trip Set Points: (40)

NI Detector Power Supply Cut-off Power Level: (15)

NI Detector Power Supply Turn-on Power Level: (15)

Instrument Failure Mode: (30)

Temperature Compensation For DP Transmitters: (1)

Level Reference Leg: (3)

Unique System Desc: (100) 8/30/2007 WC1 N/A CNTMNT RAD GTUO001 CONTAINMENT RADIATION AVG N/A A

R/HR N/A

.1E1

.1E9 N/A N/A P

2 AVERAGE 2047 CTMT SOUTH, 2068 CTMT NORTH HI = 100 R/HR N/A N/A LOW/LOC=LOP N/A N/A RMS MONITORS GTRE0059 GTRE0060 AVG OF RMS MONITORS REF USAR TABLE 11.5-4

WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)

Reactor Unit: (3)

Data Feeder: (10)

NRC ERDS Parameter: (12)

Point ID: (12)

Plant Spec Point Desc: (40)

Generic/Cond Desc: (32)

Analog/Digital: (1)

Engr Units/Dig States: (12)

Engr Units Conversion: (40)

Minimum Instr Range: (10)

Maximum Instr Range: (10)

Zero Point

Reference:

(6)

Reference Point Notes: (40)

PROC or SENS: (1)

Number of Sensors: (3)

How Processed: (40)

Sensor Locations: (40)

Alarm/Trip Set Points: (40)

NI Detector Power Supply Cut-off Power Level: (15)

NI Detector Power Supply Turn-on Power Level: (15)

Instrument Failure Mode: (30)

Temperature Compensation For DP Transmitters: (1)

Level Reference Leg: (3)

Unique System Desc: (100) 8/30/2007 WC1 N/A WIND DIR RDA0001 10 METER WIND DIRECTION #1 N/A A

DEG N/A 0

360 N/A DEGFR NORTH S.

1 N/A 10 METER LEVEL MET TOWER N/A N/A N/A N/A LOW=LOP N/A WIND DIRECTION XMTR RDZE0001

WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)

Reactor Unit: (3)

Data Feeder: (10)

NRC ERDS Parameter: (12)

Point ID: (12)

Plant Spec Point Desc: (40)

Generic/Cond Desc: (32)

Analog/Digital: (1)

Engr Units/Dig States: (12)

Engr Units Conversion: (40)

Minimum Instr Range: (10)

Maximum Instr Range: (10)

Zero Point

Reference:

(6)

Reference Point Notes: (40)

PROC or SENS: (1)

Number of Sensors: (3)

How Processed: (40)

Sensor. Locations: (40)

Alarm/Trip Set Points: (40)

NI Detector Power Supply Cut-off Power Level: (15)

NI Detector Power Supply Turn-on Power Level: (15)

Instrument Failure Mode: (30)

Temperature Compensation For DP Transmitters: (1)

Level Reference Leg: (3)

Unique System Desc: (100) 8/30/2007 WC1 N/A WIND SPEED RDS0001 10 M WIND SPEED #1 WIND SPEED @ RX SITE A

MPH N/A

.5 100.0 N/A N/A S1 N/A 10 METER LEVEL MET TOWER N/A N/A N/A LOW=LOP N/A, N/A WIND SPEED XMTR RDSE0001

WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)

.Reactor Unit: (3)

Data Feeder: (10)

NRC ERDS Parameter: (12)

Point ID: (12)

Plant Spec Point Desc: (40)

Generic/Cond Desc: (32)

Analog/Digital: (1)

Engr Units/Dig States: (12)

Engr Units Conversion: (40)

Minimum Instr Range: (10)

Maximum Instr Range: (10)

Zero Point

Reference:

(6)

Reference Point Notes: (40)

PROC or SENS: (1)

Number of Sensors: (3)

How Processed: (40)

Sensor Locations: (40)

Alarm/Trip Set Points: (40)

NI Detector Power Supply Cut-off Power Level: (15)

NI Detector Power Supply Turn-on Power Level: (15)

Instrument Failure Mode: (30)

Temperature Compensation For DP Transmitters: (1)

Level Reference Leg: (3)

Unique System Desc: (100) 8/30/2007 WC1 N/A STAB CLASS RDT0004 60M-10M TEMP DIFF C #1 AIR STABILITY AT THE RX SITE A

DEGC N/A

-4

+6 N/A N/A P

2 SUBTRACTION METEOROLOGICAL TOWER N/A N/A N/A Low=LOP N/A N/A TEMPERATURE DIFFERENCE BETWEEN 60 METER LEVEL AND 10 METER LEVEL IN DEGREES CELCIUS

WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)

Reactor Unit: (3)

Data Feeder: (10).

NRC ERDS Parameter: (12)

Point ID: (12)

Plant Spec Point Desc: (40).

Generic/Cond Desc: (32)

Analog/Digital: (1)

Engr Units/Dig States: (12)

Engr Units Conversion: (40)

Minimum Instr Range: (10)

Maximum Instr Range: (10)

Zero Point

Reference:

(6)

Reference Point Notes: (40)

PROC or SENS: (1)

Number of Sensors: (3)

How Processed: (40)

Sensor Locations: (40)

Alarm/Trip Set Points: (40)

NI Detector Power Supply Cut-off Power Level: (15)

NI Detector Power Supply Turn-on Power Level: (15)

Instrument Failure Mode: (30)

Temperature Compensation For DP Transmitters: (1)

Level Reference Leg: (3)

Unique System Desc: (100) 8/30/2007 WC1 N/A TEMP CORE EX RJU0577 5 HOTTEST T/C AVERAGE HIGHEST TEMP @ CORE EXIT A

DEGF N/A 220 2450 N/A N/A P

50 5 HIGHEST AVERAGED UPPER CORE PLATE N/A N/A N/A OPEN N/A N/A 5 HOTTEST TC'S AVG RANGE

(-450 TO 2500) DEGF.

VALUES FROM TCCM SYSTEM RP081A OR RP081B CALIBRATED RANGE IS COMPUTER ALARMS MODE HIHI HI FP 650 645 LP 650 645 HS 650 645 HC 650 645 CS 700 (220-2450) DEGF.

LO 205 205 205 205 LOLO 220 220 220 220

WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)

Reactor Unit: (3)

Data Feeder: (10)

NRC ERDS Parameter: (12)

Point ID: (12)

Plant Spec Point Desc: (40)

Generic/Cond Desc: (32)

Analog/Digital: (1)

Engr Units/Dig States: (12)

Engr Units Conversion: (40)

Minimum Instr Range: (10)

Maximum Instr Range: (10)

Zero Point

Reference:

(6)

Reference Point Notes: (40)

PROC or SENS: (1)

Number of Sensors: (3)

How Processed: (40)

Sensor Locations: (40)

Alarm/Trip Set Points: (40)

NI Detector Power Supply Cut-off Power Level: (15)

NI Detector Power Supply Turn-on Power Level: (15)

Instrument Failure Mode: (30)

Temperature Compensation For DP Transmitters: (1)

Level Reference Leg: (3)

Unique System Desc: (100) 8/30/2007 WC1 N/A NI POWER RNG SEU0001 PWR RANGE CH AVERAGE NI, POWER RANGE A

PCT N/A 0

240 N/A N/A P.

4 AVERAGE OF 4 POWER CHANNELS BETWEEN RX CAVITY WALL AND RX VESSEL HIGH=109%; LOW=25% W/P-10 UNBLOCKED N/A N/A LOW=LOP N/A N/A POWER RANGE XMTRS SEN0049A CH1 Q4 SEN0050A CH2 Q2 SEN0051A CH3 Q1 SEN0052D CH4 Q3 COMP ALARMS-NONE I

WCRE-02, PART III ERDS DATA POINT LIBRARY REFERENCE FILE DATE: (8)

Reactor Unit: (3)

Data Feeder: (10)

NRC ERDS Parameter: (12)

Point ID: (12)

Plant Spec Point Desc: (40)

Generic/Cond Desc: (32)

Analog/Digital: (1)

Engr Units/Dig States: (12)

Engr Units Conversion: (40)

Minimum Instr Range: (10)

Maximum Instr Range: (10)

Zero Point

Reference:

(6)

Reference Point Notes: (40)

PROC or SENS: (1)

Number of Sensors: (3)

How Processed: (40)

Sensor Locations: (40)

Alarm/Trip Set Points: (40)

NI Detector Power Supply Cut-off Power Level: (15)

NI Detector Power Supply Turn-on Power Level: (15)

Instrument Failure Mode: (30)

Temperature Compensation For DP Transmitters: (1)

Level Reference Leg: (3)

Unique System Desc: (100) 8/30/2007 WC1 N/A NI SOURC RNG SEU0002 SOURCE RANGE AVERAGE NI, SOURCE RANGE A

CPS N/A 1

1E6 N/A N/A P

2 AVERAGE BETWEEN RX CAVITY WALL AND RX VESSEL 1E5 AUTO=P10 MAN=P6 AUTO=P6 DECR (30) LOW=LOP N/A N/A INT RANGE XMTRS SENE0031 SENE0032 P6=10E-10 INTER RANGE AMPS P10=10% POWER RANGE COMP ALARMS-NONE