MSIVs 3.7.2 ACTIONS (continued)

CONDITION REQUIRED ACTION COMPLETION TIME D.

Required Action and D.

Be in MODE 3.

6 hours6.944444e-5 days <br />0.00167 hours <br />9.920635e-6 weeks <br />2.283e-6 months <br /> associated Completion Time of Condition C not AND met.

D.2 Be in MODE 4.

12 hours1.388889e-4 days <br />0.00333 hours <br />1.984127e-5 weeks <br />4.566e-6 months <br /> SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.2.1 NOTE ----------------------------

Only required to be performed in MODES I. and 2.

Verify the isolation time of each MSIV is within In accordance limits.

with the Inservice Testing Program SR 3.7.2.2 NOTE ----------------------------

Only required to be performed in MODES 1 and 2.

Verify each MSIV actuates to the isolation position 24 months on an actual or simulated actuation signal.

Prairie Island Units i and 2 Unit I - Amendment No. 4-58 1f81l Unit 2 - Amendment No. 449171