Tech Spec Pages for Amendments 316 and 306 Regarding Allowable Value for Turbine Trip on Low Trip System Pressure (TS-07-01)
ML072670149
Person / Time
Site: Sequoyah  
(DPR-077, DPR-079)
Issue date: 09/20/2007
From:
NRC/NRR/ADRO/DORL/LPLII-2
To:
Moroney B, NRR/DORL, 415-3974
Shared Package
ML072550285 List:
References
TAC MD4680, TAC MD4681
Download: ML072670149 (2)


Text

REACTOR FUNCTIONAL UNIT

14. Deleted
15. Undervoltage-Reactor Coolant Pumps
16. Underfrequency-Reactor Coolant Pumps
17. Turbine Trip A.

Low Trip System Pressure B. Turbine Stop Valve Closure

18. Safety Injection Input from ESF
19. Intermediate Range Neutron Flux - (P-6) Enable Block Source Range Reactor Trip
20. Power Range Neutron Flux (not P-10) Input to Low Power Reactor Trips Block P-7 TABLE 2.2-1 (Continued)

TRIP SYSTEM INSTRUMENTATION TRIP SETPOINTS NOMINAL TRIP SETPOINT ALLOWABLE VALUES 5022 volts-each bus 56.0 Hz - each bus 45 psig 1% open Not Applicable 1 x 104% of RATED THERMAL POWER 10% of RATED THERMAL POWER

_ 4739 volts-each bus

> 55.9 Hz - each bus

> 39.5 psig

_1% open Not Applicable

> 6 x 10-5% of RATED THERMAL POWER

_ 12.4% of RATED THERMAL POWER SEQUOYAH - UNIT 1 2-6a Amendment No. 16, 85, 136, 141, 307, 310, 316

REACTOR TF FUNCTIONAL UNIT

b.

RCS Loop AT Equivalent to Power > 50% RTP Coincident with Steam Generator Water Level -- Low-Low (Adverse) and Containment Pressure (EAM) or Steam Generator Water Level -- Low-Low (EAM)

14. Deleted
15. Undervoltage-Reactor Coolant Pumps
16. Underfrequency-Reactor Coolant Pumps
17. Turbine Trip A.

Low Trip System Pressure B., Turbine Stop Valve Closure

18. Safety Injection Input from ESF TABLE 2.2-1 (Continued)

RIP SYSTEM INSTRUMENTATION TRIP SETPOINTS NOMINAL TRIP SETPOINT ALLOWABLE VALUES 15.0% of narrow range instrument span 0.5.psig 10.7% of narrow range instrument span 5022 volts-each bus 56.0 Hz - each bus 45 psig 1% open Not Applicable

> 14.4% of narrow range instrument span

<0.6 psig

> 10.1% of narrow range instrument

>_ 4739 volts - each bus

> 55.9 Hz - each bus

_> 39.5 psig

> 1% open Not Applicable SEQUOYAH - UNIT 2 2-7 Amendment Nos. 7, 76, 132, 296, 299,306