Staff Exhibit 4 Exelon Procedure TQ-AA-122, Rev 3; Qualification and Certification of Nondestructive (NDE) Personnel

Exeb nsM Nuclear TQ-AA-I 22 Page Revision 1 of 52 I Level 2 - Reference Use

1.

1.1.

1.2.

1.3.

2.

2.1.

2.2.

2.2.1.

2.3.

QUALIFICATiON AND CERTIFICATION Of NONDESTRUCTIVE (NDE)

PERSONNEL PURPOSE To establish requirements and administrative controls for the qualification and personnel in nondestructive examination (NE).

This procedure applies to all Exelon Nuclear, Amergen Energy and P E G (as applicable) personnel certified or recertified in N E. It shall also apply when Exelon Nuclear certifies Exelon personnel of other business units outside of Exelon Nuclear, or when Exelon Nuclear certifies contractor personnel who are in the temporary employ of Exelon Nuclear.

certification of Exelon Nuclear, Amergen Energy and PSEG (as applicable)

I Certifications issued in accordance with earlier Exelon Nuclear, Amergen Energy, PSEG or their predecessor companies certifcation procedures, shall remain valid until such time as recertification is required or they are revoked or terminated.

I TERMS AND DEFINITIONS Certification - Written testimony of qualification.

I Eddy Current Analyst [ET-AI - An advanced progression of Eddy Current Testing (ET), which specializes in the evaluation of non-ferromagnetic heat exchanger tubing 1 utilizing conventional and advanced techniques such as multiple frequency probss, motorized rotating pancake coils (MRPC), etc. Current certification in eddy current (ET) is a prerequisite to certification as an eddy current Analyst (ET-A).

Eddy Current Testina /ET) - A method of examination in which an alternating electrical (Eddy) current is induced in the part to be examined. Variations in the part such as a flaw or a change in thickness, cause a disruption in the induced current field and are displayed on a meter or cathode ray tube. Evaluation of displayed or recorded eddy current data, with the exception of ASME Section XI examination of steam generator tubing, is included in eddy current testing. Evaluation of steam generator examination data requires an additional Eddy Current Analyst (ET-A) certification.

I Maanetic Particle Testinn (MT) - A method of examination of ferromagnetic materials in which the part to be examined is magnetized and a fine metallic powder applied to the part accumulates at magnetic feld disruptions caused by surface or slight I y s u bs u dace discontinuities.

2.3.1.

2.4.

2.5.

2.5.1.

2.6.

2.7.

2.8.

2.8.1.

2.9.

TQ-AA-122 Page Revision3 2 of 52 I Magnetic Particle Testing - Limited (MT-L) - A limited sub-division of magnetic particle testing (MT), defined above. Restricted to the dry powder, color contrast, electromagnetic yoke technique only.

Outside Anency - An outside agency is an organization or individual that provides NDE Level Ill or NDE Instructor services and whose qualifications to provide these services have been reviewed and accepted by the organization that engages the outside agency.

Penetrant Testinn (PT) - A method of examination utilizing the principle of capillary action of a liquid to draw a dye into discontinuities open to the surface of a part or component enhancing the appearance and detectability of a discontinuity.

Penetrant Testinn - Limited (PT-L) - A limited sub-division of penetrant testing (PT), defined above. Restricted to the solvent removable, color contrast technique only.

Procedure - In nondestructive examination (NDE) a procedure is an orderly sequence of rules that describes how a specific technique shall be applied.

Qualification - The skill, training, knowledge, and experience required for personnel to properly perform the duties of a specific job, as demonstrated by compliance with Exelon Nuclear requirements for certification.

Radiouraphic Testinn (RT) - An examination method that uses radiation to penetrate through the object being examined in order to record density contrasts on special film or other recording medium. Radiographic testing also includes the development of exposed film and the evaluation of developed film including all attributes of radiographic interpretation as defined below.

Radioqraphic Interpretation (RT-I) - A Limited sub-division of Radiographic Testing (RT) defined above, which is restricted to the examination of exposed and developed radiographic images to verify film quality, including densities, artifacts, penetrameters, geometric unsharpness, component ID, etc., and to evaluate radiographic images to determine the acceptability of examined components with respect to specified codes and standards.

Technique - A technique or category is a specific way of utilizing a particular nondestructive examination (NDE) method. Each technique or category is identified by at least one particular important variable from another technique or category within the method.

2.9.1 *

2. I O.

2.10.1.

2.10.2.

2.1 1.

2.11.I.

2.1 1.2.

2.12.

TQ-AA-I 22 Page Revision 3 of 52 I Applicable nondestructive examination (NDE) methods with associated techniques:

1.
2.
3.
4.
5.
6.

ET Method - Bobbin or Surface Techniques; MT Method - Dry or Wet Techniques; PT Method - Visible or Fluorescent Techniques; RT Method - Single-Wall or Double-Wall; UT Method - Angled or Straight Techniques; VT Method - Direct or Remote Techniques; Ultrasonic Testinq (UT) - A method of examination in which high frequency sound I waves are introduced into the component to be examined. Sound waves, which are reflected from discontinuities, or other interfaces, are displayed as indications, usually on a cathode ray tube.

Ultrasonic Testing Longitudinal (UT-L) - A limited sub-division of ultrasonic testing (UT), defined above, which is restricted to the use of 0 degree, straight beam transducers for thickness measurements or flaw detection.

Ultrasonic Thickness Measurements (UT-MI - A limited sub-division of ultrasonic testing (UT), defined above, which is restricted to the use of 0 degree, straight beam transducers for the sole purpose of determining thickness of materials and components.

Visual Testinn-l (VT-1) - A limited visual examination specific to ASME Section XI which is the observation of exposed surfaces of a part, component, or weld to determine its physical condition including such irregularities as cracks, wear, erosion, corrosion, or physical damage.

Note: Detailed Visual as the applicable requirements of ASME Section XI, 2001 Edition, Subsections IWE and IWL shall be contained in the VT-1 Method. The examiner certified to VT-1 shall also be certified to examine components specifed to Detailed Visual. Detailed Visual shall be applied to Class MC containment surfaces; and Class CC concrete surfaces and anchorage hardware.

Visual Testing - I Boltinq (VT-1 B) - A limited sub-division of Visual Testing - 1 (VT-I ) defined above, which is restricted to the examination of bolting components including bolts, studs, nuts, washers, etc., 2 inches and less in diameter.

Visual Testing - I Concrete (VT-1 C) - A limited sub-division of Visual Testing - 1 (VT-1) defined above, which is restricted to the direct or remote examination of selected suspect areas of containment concrete surfaces.

Visual Testinq - lnvessel Visual Inspection (VT-IWI )- A limited sub-division of Visual Testing - I (VT-I) defined above, and Visual Testing - 3 (VT-3) defined below, which is restricted to the remote or direct examination of reactor pressure vessel internal surfaces and components to determine their physical condition

TQ-AA-122 Page Revision 4 of 52 I including such irregularities as cracks, wear, loose parts, debris, and the loss of integrity at bolted or welded connections.

2.13.

Visual Testinn - 2 WT-2) - A limited visual examination specific to ASME Section XI which is the observation to locate evidence of leakage from pressure retaining components, or abnormal leakage from components with or without leakage collection systems during a system pressure or functional test.

2.14.

Visual Testinn - 3 (VT-3) - A limited visual examination specific to ASME Section XI which is the observation to determine the general mechanical and structural condition of components and their supports, such as the verification of clearances, settings, physical displacements, loose or missing parts, debris, corrosion, wear, erosion, or the loss of integrity at bolted or welded connections. The VT-3 examinations shall include examinations for conditions that could affect operability of functional adequacy of snubbers, and constant load and spring type supports.

Note: General Visual as the applicable requirements of ASME Section XI, 1992 Edition, 1992 Addenda, Subsection IWE shall be contained in the Vi-3 Method. The examiner certified to VT-3 shall also be certified to examine components specified to General Visual. General Visual shall be applied to Class MC pressure retaining components and their integral attachments; and Class CC metallic shell, penetration liners and their integral attachments.

2.14.1.

Visual Testinn - 3 Concrete (VT-SC) - A limited sub-division of Visual Testing-3 (VT-3) defined above, which is restricted to the direct or remote observation of coated and uncoated concrete containment structure and surfaces for evidence of conditions indicative of damage or degradation.

2.14.2.

Visual Testinn - 3 Snubbers (VT3S) - A limited sub-division of VT-3 defined above, which is restricted to the examination of snubbers and their attachments.

3.

RESPONSIBILITIES 3.1.

Outaqe Services I

3.1.I. Responsible for development, approval and implementation of this procedure.

3.1.2.

3.2.

NDE Services Manaser Responsible for appointment of designated persons/positions to this procedure.

TQ-AA-122 Page Revision 5 of 52 I 3.2.1.

3.2.2.

3.2.3.

3.2.4.

3.2.5.

3.2.6.

3.2.7.

3.3.

3.3.1.

3.3.2.

3.3.3.

3.4.

3.4.1.

3.5.

3.5.

I.

3.6.

3.6.1.

3.6.2.

3.6.3.

Maintains certification records for each currently certified NDE Level II I examiner.

Provides assistance to the Principal Level Ill in the administration of the NDE Program.

May perform the duties of the Principal Level Ill when designated.

Responsible for appointment of NDE Principal Level Ill.

Responsible for appointment of NDE Instructor.

Approves the use of contracted services for training and testing of NDE personnel.

Selects suitable NOE Level Ill candidates, evaluates their performance, training history and qualifieskertifies suitable individuals.

Principal Level I l l A qualified individual appointed by NDE Services Manager.

This position is equivalent to the Principal Level Ill Examiner as specified in ASME Section XI, 1992 Edition with 1992 Addenda and later Editions.

May designate the Principal Level Ill position in an absence.

Responsible Individual A qualified individual appointed by Corporate Asset Management to approve the applicable Visual Testing portions of this procedure ensuring the qualificationkertification requirements of ASME Section XI, Subsection IWE, 1998 Edition are met for the Station(s) with an approved Relief Request through an authorized NRC SER.

Responsible Enaineer A qualified individual (Registered Professional Engineer experienced in evaluating in-service conditions of structural concrete) appointed by Corporate Asset Management to approve the applicable Visual Testing portions of this procedure to ensure the qualificationkertification requirements of ASME Section XI are met.

NDE Level Ill Examiners Develops, approves, administers, and grades, NDE qualification examinations for Level I and Level II personnel.

Evaluates NDE performance, training, and job experience of Level I and Level II candidates, and certifies suitable candidates.

May perform the duties of the Principal Level Iil when designated.

3.6.4.

3.7.

3.7.1.

3.7.2.

3.7.3.

3.7.4.

4.

4.1.

4.1.I 4.1.3.

4.1.4.

4.1.4.1.

4.1.5 4.1.5.1 TQ-AA-122 Revision 3 Page 6 of 52 NDE Level Ill Examiners assigned to and responsible for the NDE program activities at a station shall maintain certification records for each currently certified NDE Level I and Level II examiner at the respective station.

NDE Instructors Develops appropriate classroom and laboratory materials for initial and supplemental training of NDE Level I, II, and Ill personnel.

Conducts classroom and laboratory training sessions for all levels of NDE personnel.

Conducts classroom and laboratory testing sessions for all levels of NDE personnel.

Conducts qualification testing for all levels of NDE personnel.

MAIN BODY Personnel Qualification Personnel certified in nondestructive examination to this procedure are qualified in accordance with ASNT SNT-TC-IA, through 1984 Edition; ANSVASNT CP-189, 1991 and 1995 Editions; and ASME Section XI, 1986 Edition through 2001 Edition, 2003 Addenda, as applicable. 4.1.2. Personnel performing ultrasonic examinations to fulfill the requirements of ASME Section XI must also meet the requirements of the Appendix VI1 (Attachment 5 to this procedure).

As an alternative to the certification requirements contained in the main body of this Ill Examiner shall be qualified to, and be responsible for: procedure, personnel may be qualified to perform VT-2 examinations in accordance with Code Case N-546 and to this procedure.

Other requirements, beyond those contained herein, may apply to specific examinations or certain examination types. Examples of this include the requirement to be Performance Demonstration Initiative (PDI) qualified to perform Section XI, Appendix VI1 I ultrasonic examinations, the NRC requirement far radiographers to be third party certified in radiation safety, or the requirement to be a Qualified Data Analyst (QDA) to perform evaluation of eddy current data of steam generator tubing.

Certification to this procedure is a prerequisite to the additional, supplemental qualifications described above.

There are four levels of qualification, which are defined in terms of the skills, knowledge, and experience required in a given method or methods to perform specified NDE activities.

NDE Level I - An NDE Level I Examiner shall be qualified to:

PERFORM specific equipment set-ups

TQ-AA-122 Revision 3 Page 7 of 52 PERFORM specific calibrations and examinations RECORD data to written instructions IMPLEMENT written NDE instructions under the guidance of a certified NDE Level II or Ill.

A. NDE Level I Examiners shall not independently EVALUATE or INTERPRET the results of a nondestructive examination.

4.1 5.2. NDE Level II - An NDE Level II Examiner shall be qualified to:

PERFORM examinations SET-UP and CALIBRATE equipment INTERPRET and EVALUATE results with respect to applicable codes, standards, and specifications REPORT NDE results.

A. NDE Level II Examiners shall BE thoroughly FAMILIAR with the scope and limitations of the test method and EXERCISE assigned responsibility for the on-the-job training of trainees and NDE Level I examiners.

4.1 5.3. NDE Level Ill -An NDE Level ESTABLISH I NG examination techniques and procedures INTERPRETING codes, standards, specifications, and procedures DESIGNATING the particular test methods, techniques, and procedures to be used RESPONSIBLE for NDE operations for which qualified and to which assigned INTERPRETING and EVALUATING NDE results in terms of existing codes, standards, and specifications QUALIFYING and CERTIFYING Level I and Level II personnel for NDE certification.

A.

NDE Level I l l Examiners shall have sufficient practical background in applicable materials, fabrication, and product technology to ESTABLISH techniques and to ASSIST in establishing acceptance criteria.

NDE Level Ill Examiners shall EVALUATE the adequacy of specific programs used to train and test inspection, examination, and testing personnel.

NDE Level Ill Examiners shall EVALUATE the experience history of lower level personnel and make recommendations for NDE certifications.

NDE Level Ill Examiners shall have a general FAMILIARITY with other appropriate NDE methods for which they are not certified.

B.

C.

D.

TQ-AA-I 22 Page Revision 8 of 52 I 4.1 5.4. NDE Instructor - An NDE Instructor shall have the skills and knowledge to PLAN, ORGANIZE, and PRESENT classroom, laboratory, demonstration, and/or on-the-job NDE instruction, training, and/or education programs in accordance with approved course outlines.

A.

An NDE Instructor may administer qualification examinations, written and practical.

4.1 5 5 4.2 4.2.1 4.2.2 4.2.3.

Trainee - While in the process of being qualified and certified to Level I, II or 111, an individual shall be considered a Trainee. This is not a certification level, and a Trainee shall WORK at all times under the direction of a certified individual (NDE Level II or NDE Level 111) and shall pJ independently CONDUCT examinations, INTERPRET or EVALUATE the results of an examination, or REPORT examination results.

Education, Training and Experience All candidates for initial certification as an NDE Level I, Level II or Level Ill shall possess as a minimum, a High School Diploma or equivalent (GED).

Candidates for certification as NDE Level I, Level II or Level Ill shall complete sufficient organized training. This training shall be as follows:

Training shall be conducted in accordance with a course outline approved by an NDE Level Ill. Additional training guidance is discussed in ER-AA-335-1002, NDE Training.

Course shall include topics as listed in Appendix B of CP-189, SNT-TC-1A or ASME Section XI Appendix VI1 Supplement 1 for the appropriate NDE method, plus additional topics as deemed necessary by the NDE Level Ill.

Sequence, content, amount of time spent, and depth of coverage for each topic shall be approved by an NDE Level Ill.

I Training programs shall include sufficient examinations to demonstrate necessary information comprehension. To receive credit for the training, the individual shall pass a final examination covering the topics contained in the training program.

An NDE Instructor shall present the training, however, the NDE Instructor may delegate personnel with specialized expertise (metallurgists, engineers, NDE Level Ill and etc.) who are not certified to this procedure, but are subject matter experts (SME) in presentation of specific information. An NDE Level 111 shall in all cases be responsible for the content of the completed course.

NDE Level I and II personnel shall meet the minimum training and experience requirements listed for the method and level; 4.2.3.1., Tables IT, 2T, & 3T LIST the minimum training requirements for each NDE method and level.

TQ-AA-122 Page Revision 9 of 52 I 4.2.3.2.

4.2.4.

4.2.5.

4.2.6.

4.2.6.1.

4.2.6.2.

4.2.6.3.

4.2.6.4.

4.2.7.

4.2.7.1., Tables 1 E, 2E, & 3E LIST the minimum experience requirements for each NDE Method and level.

NOTE:

Reference ATTACHMENT 6

for Station specific traininglexperience requirements for personnel certified VT-2 in accordance with Code Case N-546.

Candidates for initial certification to NDE Level I, Level I1 and Level 111 shall document sufficient experience in accordance with Attachment 8 - Documentation of Initial NDE Experience and Training.

Exelon may accept a candidates previous training and experience, if verified and documented. Any claimed training or experience, which cannot be verified and documented, should be considered invalid. The NDE Level Ill responsible for certifying the candidate shall verify and validate the documentation for the minimum required training and experience in each method. This verification and validation may be documented on Attachment 8 - Experience Verification / Validation Record.

NDE Level Ill examiners shall FULFILL one of the following minimum criteria for education and experience:

GRADUATED from a 4-year accredited engineering science college or university with a degree in engineering or science, plus 1 year experience in nondestructive examination in an assignment comparable to that of an NDE Level II Examiner in examination met hod( s),

COMPLETED with passing grades at least the equivalent of 2 full years of engineering or science study at a university, college, or technical school, plus 2 years experience in an assignment comparable to that of a Level II Examiner in the examination method(s),

Have four years EXPERIENCE in an assignment comparable to that of a Level II examiner in the examination method(s).

POSSESSION of a valid, current, ASNT Level Ill certificate in a particular NDE method satisfies all of the above Level Ill Education, Training, and Experience requirements.

NDE Instructors shall FULFILL the following minimum criteria to be considered for appointment as an NDE Instructor:

HOLD a current Level Ill certification in the applicable NDE method, or have fulfilled the NDE Level Ill Basic and Method requirements of the applicable NDE Method,

TQ-AA-I 22 Page Revision 10 of 52 I and 4.2.7.2.

4.3.

4.3.1.

4.3.2.

POSSESS a current teac,,er or vocational instructor certificate issued by a state, municipal, provincial, or federal authority or have completed a minimum of 40 hours4.62963e-4 days <br />0.0111 hours <br />6.613757e-5 weeks <br />1.522e-5 months <br /> instruction in training and teaching techniques.

Visual Acuity Examination All Examiners certified to NDE Level I, Level II, or Level Ill, shall be tested to assure minimum requirements for near vision acuity, far vision acuity, and color contrast differentiation, as described below.

1.

ADMINISTER tests prior to certification and annually thereafter.

2.

An NDE Level I l l or registered professional medical personnel shall ADMINISTER acuity examinations; or other qualified individuals designated and documented by the NDE Level Ill Examiner.

Minimum acceptable requirements for each vision test, natural or corrected, are:

1.

Near Vision - The ability, in at least one eye, to read Jaeger number 1 on a standard Jaeger test at a nominal minimum distance of not less than 12 inches. ADJUST the actual test distance based on the results of measurements of the average lower case height of the test chart and shall MEET Figure I below:

FIGURE 1 Near Distance Acuity Test Distances And Character Heights Distance Character Height InCheS Inches 12 0.022 13 0.024 14 0.025 15 0.027 16 0.029 Test Maximum Lower Case Note: The test distance (eye to chart) and corresponding character heights provide a visual angle of 6.25 minutes which is equivalent to a Snellen fraction of 20125.

2.

Far Vision - The ability, in at least one eye, to DISCERN Snellen fraction 20/30 symbols at a distance of 20 feet.

Color Contrast Differentiation - the ability to DISTINGUISH colors and

3.

TQ-AA-I 22 Page Revision 11 of 52 I differentiate contrast between colors normally encountered in NDE shall be demonstrated by the capability of distinguishing various numerals and patterns on standard lshihara Color Contrast Plates at a distance of less than 30 inches or equivalent (e.g. colored wire, colored yarn, etc.).

4.3.3. to this procedure PROVIDES additional details and specific requirements in the administration of a vision examination.

4.4.

NDE Qualification Examinations 4.4.1.

ADMINISTER the written examinations without access to reference material (closed book), except that necessary data such as graphs, tables, specifications, procedures, and codes essential for test implementation, may be provided by the NDE Level 111 responsible for the administration of the test.

4.4.2.

Randomly SELECT the required number of questions for each written examination from a question bank, which represents a cross section of the body of knowledge applicable to each method and NDE level.

INCLUDE the minimum number of questions listed in Attachment 3 in the written examinations for certifying NDE Level I and Level II personnel.

4.4.2.1.

NOTE: Reference ATTACHMENT 6 for Station specific examination requirements for personnel certified VT-2 in accordance with Code Case N-546.

4.4.3 The format and content of the examinations for NDE Level I and II shall CONSIST of each of the following:

I.

General (Written) examination COVERS the basic test principles relative to the applicable testing method, and to the extent commensurate with the NDE level for which the examination is given.

2.

Specific (Written) examination shall COVER the equipment, operating procedures, and testing techniques that the candidate may encounter in their specific assignment. The examination shall also COVER the codes, specifications, and acceptance criteria used by Exelon Nuclear in its NDE examinations.

3.

Practical examination REQUIRES the candidate to demonstrate to the satisfaction of the Level Ill examiner that the candidate is familiar with and can calibrate and operate the necessary test equipment and record and analyze the resultant information to the degree required.

Level I - The candidate shall DEMONSTRATE proficiency using the applicable NDE method to EXAMINE at least one test sample for each technique to be used in the candidates job. The test samples shall be representative of the products that the candidate will encounter in performing the job function.

TQ-AA-122 Revision 3 Page 12 of 52 4.4.4 4.4.4.1 4.4.4.2 Level II - The candidate shall DEMONSTRATE proficiency by PERFORMING the applicable NDE method in examining at least one sample for each technique to be used in the candidates job, and a minimum of two samples per method and by interpreting, evaluating, and documenting the results of the examination. The test samples shall be representative of the product that the candidate will encounter in performing the job functions.

The format and content of the examinations for NDE Level Ill shall CONSIST of each of the following; Basic (Written) examination shall VERIFY the candidates knowledge of such diverse topics as materials processing and fabrication, administration of a Written Practice, and general knowledge of other NDE methods. This examination shall consist of at least 75 questions:

A. Minimum 10 (twenty to thirty percent of 50 for ASME Section XI) of the questions shall COVER ANSVASNT CP-189 and minimum 20 questions shall be related to the understanding the SNT-TC-1 A document. The quantity of questions for understanding these two documents shall be a minimum of 30.

B. Minimum 15 (thirty to fifty percent of 50 for ASME Section XI) of the questions shall COVER other NDE methods and be similar to the Level II questions published by ASNT for the NDE methods referenced in ANSVASNT CP-189 and SNT-TC-I A. The quantity of questions for understanding these other methods shall be a minimum of 15.

C. Minimum 30 (twenty to thirty percent of 50 for ASME Section XI) of the questions shall COVER applicable materials, products, and fabrication technology for ASME Section XI and SNT-TC-1 A requirements. The quantity for understanding these topics shall be a minimum of 30.

I Note: The Basic is required only once if certification is sought in more than one method and/or the re-qualification method examination is successfully completed prior to the expiration (five years) of the initial qualification method exam ination.

Method (Written) examination shall VERIFY the candidates knowledge of the basic fundamentals and principles of the method, and the use of applicable codes and procedures. It shall consist of at least 70 questions:

A.

Minimum 13 (twenty to forty percent of 65 for ASME Section XI) of the questions shall COVER fundamentals and principles of the method and shall be similar to published ASNT Level Ill questions for ASME Section XI requirements and a minimum 30 shall cover the same for SNT-TC-INCP-189. The quantity for understanding these topics shall be a minimum of 30.

B.

Minimum 20 (thirty to fifty percent of 65 for ASME Section XI) of the questions shall COVER amlications and establishment of Procedures and techniaues

TQ-AA-I 22 Revision 3 Page 13 of 52 4.4.4.3.

4.4.4.4.

4.4.4.5.

4.4.5.

4.5.

4.5.1.

4.5.2.

and shall be similar to published ASNT Level I l l questions for ASME Section XI requirements and a minimum 15 shall cover the same for SNT-TC-INCP-189. The quantity for understanding these topics shall be a minimum of 20.

C.

Minimum 13 (twenty to thirty percent of 65 for ASME Section XI) of the questions shall COVER the capability to interpret codes standards and specifications for the method for ASME Section XI requirements and a minimum 20 shall cover the same for SNT-TC-INCP-189. The quantity for understanding these topics shall be a minimum of 20.

Specific (Wriften) examination shall VERIFY the candidates knowledge of equipment, techniques, procedures, the NDE requirements of ASME Section XI, and administration of Exelons written practice. It shall consist of at least 30 questions.

Practical examination shall VERIFY the candidates ability to develop NDE procedures. The candidate shall PREPARE an NDE procedure appropriate to Exelons needs; however if documented experience demonstrates that the candidate has previously prepared acceptable NDE procedures in the method using specifications codes, and standards that are applicable to Exelon, a practical examination is not required. If experience is substituted for the practical examination the pertinent practical experience shall be documented in the individuals certification records file.

Demonstration examination shall MEASURE the candidates ability to PERFORM examinations and evaluate examination results. The candidate shall DEMONSTRATE proficiency by performing the applicable NDE method in examining at least one sample for each technique to be used in the candidates job, and a minimum of two samples per method and by interpreting, evaluating, and documenting the results of the examination. The test samples shall be representative of the product that the candidate will encounter in performing the job functions.

Controls to assure confidentiality of qualification test materials shall be ESTABLISHED to prevent unauthorized access to these materials. These controls shall include, as a minimum, locked file cabinets for hardcopy test questions banks, password requirements for computer based test question databanks, and locked cabinets for all practical test samples. Additional controls may be established as necessary to assure security of qualification test materials.

Administration and Grading In no case shall any examination be PREPARED or ADMINISTERED by ones self or by ones subordinate.

An NDE Level I l l certified in the applicable method or an NDE Instructor shall be responsible for the ADMINISTRATION and GRADING of Level I and Level II qualification examinations. The administration and grading of examinations may be delegated.

4.5.3.

4.5.3.1.

4.5.3.2.

4.5.3.3.

4.5.4.

4.5.4.1.

4.5.4.2.

4.5.4.3.

4.5.4.4.

4.5.5.

TQ-AA-122 Page Revision 14 of 52 I The Principal NOE Level Ill or NDE Instructor is responsible for the I

ADMINISTRATION and GRADING of NDE Level Ill qualification examinations. This responsibility may be delegated by the Principal NDE Level Ill to an NDE Level Ill who is certified in the applicable method.

BASE initial certification on the Basic, Method, Specific, Practical, and Demonstration examinations. If the practical examination is waived based on documented experience, as described in 4.4.4(4), then ASSIGN an 80% for the examination and USE the 80% to calculate the composite grade.

BASE recertification of NDE Level Ill on Method, Specific, Practical, and Demonstration examinations. Alternatively, Level Ill personnel may be recertified using only the Method and Specific Examinations, provided the candidate was previously certified or recertified as an NDE Level Ill using the Written Examinations and Demonstration Examination (If a candidate has evidence of completing Level II Practical examinations, this satisfies the Demonstration examination), and further, that the candidate is not being recertified due to interrupted service as defined in 4.9.1.2.

An ASNT Level Ill certificate with a current endorsement for the applicable method satisfies the Basic and Method examination requirements.

ADMINISTER the Level I, II, Ill Practical examinations and the Level Ill Demonstration examination using a written checklist. The checklist shall address at least the following items:

The Level I Practical examination checklist shall ADDRESS proficiency in the use of techniques and equipment, proper adherence to procedure, test sequence, calibrations, materials, documentation, and extent of examination.

The Level II Practical examination checklist shall ADDRESS proficiency in the use of techniques and equipment, proper adherence to procedure, test sequence, calibration, and materials; satisfactory detection and location of discontinuities; proper extent of examination; and the accuracy and completeness of the activities and test results.

The Level Ill Practical examination checklist shall ADDRESS items relating to the technical and practical adequacy of the NDE procedure(s) prepared by the candidate.

The Level Ill Demonstration examination checklist shall ADDRESS proficiency in the use of techniques and equipment, proper adherence to procedure, test sequence, calibration, and materials; satisfactory detection and location of discontinuities; proper extent of examination; and the accuracy and completeness of the activities and test results.

DETERMINE the final grade for initial NDE certification by simple averaging of each applicable grade i.e.; General, Specific, and Practical for Level I and Level II, and

4.5.6.

4.5.6.1.

4.5.6.2.

4.6.

4.6.1.

4.7.

4.7.1.

4.7.1.I.

4.7.1.2.

4.7.1.3.

4.7.2.

4.7.3, 4.8.

4.8.1.

TQ-AA-122 Page Revision 15 of 52 I Basic Method, Specific, Practical, and Demonstration for Level I l l. The average grade must be at least 80%, and each individual exam grade must be at least 70%.

For recertification, the grades of applicable examinations administered shall be averaged to determine the overall grade.

Outside agencies may be used to ADMINISTER and GRADE examinations.

When an outside agency administers an examination and only issues a pass or fail grade, ASSIGN an 80% for each pass grade issued.

If the outside agency requires a passing grade other than 70% for any individual examination, then APPLY the higher requirement.

Note: Each outside agency shall maintain a written practice that specifies the documentation to be maintained in the agencys qualification records. This documentation shall include such information as the qualification examinations, candidates name and certification level, date of examination, overall course grade and formal qualification examination grade.

Re -examination Candidates who fail to ATTAIN the required passing grade on a qualifying or re-qualifying examination must RECEIVE additional documented training, or WAIT at least thirty days for re-examination. This training shall ADDRESS the deficiencies, which caused failure. A candidate shall not be re-examined using the examination or specimen previously failed or both.

Expiration Individual certifications shall EXPIRE; When employment with the employer is terminated.

At the end of three years, for NDE Level I and NDE Level II individuals.

At the end of five years, for NDE Level Ill individuals.

If multiple test dates are utilized for any certification, then DETERMINE the expiration date from the date of the earliest individual examination used to support that certification.

An individuals NDE certification expiration shall be documented on Attachment 4 -

NDE Certification Records, Continued Certification Record.

Re-certification Re-certification of all Levels of NDE personnel shall be by EXAMINATION, as described in Section 4.4 of this procedure.

TQ-AA-122 Page 16 of 52 Revision I 4.8.2.

4.9.

4.9.1.

4.9.1.1.

4.9.1.2.

4.9.1.3.

4.9.2.

4.10.

4.10.1.

The re-qualification activities (Le. general, method, basic, practical and demonstration examinations, as applicable) are intended to begin and be completed prior to the expiration date of the current certification period. When all re-qualification examinations are not completed prior to the previous certification period expiring, the new recertification period begins when the NDE Certification Record is completed and signed. No NDE examinations are to be performed between the dates of the expired certification and the new date of recertification.

Suspension Exelon shall SUSPEND any individuals NDE certification if; The vision examination interval exceeds one year. Certification is reinstated concurrently with passing the vision reexamination; or The individual has interrupted service - meaning the individual has not performed examinations, or related duties (reviewed or generated procedures, drawings, work scope or participated in the review or supervision of the examinations), in the certified method(s) during any consecutive twelve month period; or The individuals performance is determined to be deficient in the required method or technique for specific documented reasons.

An individuals NDE certification suspension shall be documented on Attachment 4 - NDE Certification Records, Continued Certification Record.

Revocation Exelon shall REVOKE an individuals certification when; 4.1 0.1.l.

The individual has generated procedures, drawings, work scope or participated in the review or supervision of the examinations), in the method(s) for which certified during any consecutive twenty-four month period; or PERFORMED examinations, or related duties (reviewed or 4.10.1 -2. The individuals conduct is deemed by Exelon to be or have been unethical or 4.10.2.

4.1 1.

4.11.1.

4.1 1.2.

incompetent.

NDE Certification Records, Continued Certification Record.

Reinstatement DETERMINE reinstatement of suspended NDE Level I or NDE Level II certifications by an NO Level 111. DETERMINE reinstatement of suspended NDE Level 111 certifications by the NDE Manager I Principal NDE Level I l l.

Reinstatement of expired or revoked NDE certifications shall only be through complying with the examination requirements of Section 4.4 of this procedure.

An individuals NDE certification revocation shall be documented on Attachment 4 - I

TQ-AA-I 22 Page 17 of 52 Revision I 4.1 I

.3.

An individuals NDE certification reinstatement shall be documented on - NDE Certification Records, Continued Certification Record.

4.12.

Continued Certification 4.12.1.

Continued certification documentation shall be prepared by the NDE certified individual and submitted to an NDE Level Ill or prepared by the station Level 111 prior to the Annual Review Due Date (Vision Acuity Verification expiration date). Upon acceptance, the certification shall be continued for one-year, which may be used to establish the new Annual Review Due Date.

4.12.2.

The individual shall have continual satisfactory service - meaning the individual has performed examinations, or related duties (reviewed or drawings, work scope or participated in the review or supervision of the examinations), in the certified method(s) during the recent past twelve month period.

generated procedures, 4.12.3.

A suggested method of the Annual Review Due Date is that it may coincide with the date of the required vision acuity expiration date for the purpose of continued certification. The exception will be when the certifcation expiration date arrives prior to the vision acuity expiration date; hence, the Annual Review Due Date will coincide I with the certification expiration date.

4.12.4.

Continued Certification and the Annual Review Due Date shall be documented on - NDE Certification Records, Continued Certification Record.

Note: This record and evidence of continuing performance is not applicable to VT-2 certifications acquired in accordance to ASME Code Case N-546.

5.

DOCUMENTATION 5.1.

MAINTAIN a qualification and certification file for each currently certified NDE examiner at each station. This file is a living (in-progress) file and shall CONTAIN as a minimum; 5.1.I.

Certification Records 5.1.I.I. NDE Certification Record - Levels I & II or Ill from Attachment 4 - NDE Certification Records; 5.1.I

.2.

Name and Social Security Number (optional) of certified individual; 5.1.I

.3.

Educational background (verified during Initial Qualification and Certification);

5.1.I

.4.

NDE Method and Level of Certification, including applicable techniques and restrictions for limited certifications; 5.1.I

.5. Test grades for each applicable qualification examination; results of all, and copies of the most recent employer examinations that the individual has taken or evidence

TQ-AA-122 Page Revision 18 of 52 I 5.1.I

.6.

5.1.I

.7.

5.1.I

.8.

5.1.I

.9.

5.1.I.I 0

5.1.I.I I 5.1.2.

5.1.2.1.

5.1.3.

5.1.3.1.

5.1.4.

5.1.4.1.

5.2.

5.2.1.

6.

6.1.

of successful completion of the examinations; (written examinations are maintained by the NDE Level Ill or NDE Instructor who administered the exams)

Other suitable evidence of satisfactory qualifications when such qualifications are used in lieu of examinations; For Level Ill personnel, a copy of the candidate's ASNT Level Ill Certificate (if applicable).

Composite grade (simple average of all applicable exam scores);

Dates of certification and expiration along with dates of assignment to NDE; Printed name and signature of Exelon authorized certifying individual; Satisfactory continuing performance (documented on Attachment 4).

Training Documentation Evidence of satisfactory completion of required NDE training. This may include course certificates, attendance sheets, etc., but must include dates and duration of applicable training, identification of organization providing training, name of instructor, and evidence of satisfactory completion.

Experience Documentation Evidence of sufficient applicable NDE experience :o support certification. This may include verified experience from previous employers, previous Exelon certification, experience logs, etc.

Visual Acuity Results Copies of all applicable documentation of visual acuity examinations for the duration of the certification period.

Transmittal of NDE Certification Records Transmit NDE certification records, paragraph 5.1.I above, to Records Management when personnel have terminated employment, no longer active in any NDE methodhechnique, and when their three year or five year certification has expired. NDE certification records are transmitted to the Records Management in accordance with Records Management Program, RM-AA-101 and retained in accordance with the Standard Records Retention Schedule under Record Identification 3D.127.

REFERENCES American Society for Nondestructive Testing, Recommended Practice, SNT-TC-1 A, "Personnel Qualification and Certification in Nondestructive Testing" (through 1984

6.2.

6.3.

6.4.

6.5.

6.6.

7.

7.1.

7.2.

7.3.

7.4.

7.5.

7.6.

7.7.

7.8.

TQ-AA-122 Page Revision 19 of 52 I Edition).

ANSVASNT CP-189, Standard for Qualification and Certification of Nondestructive Testing Personnel (1 991 and 1995 Edition).

ASME Boiler and Pressure Vessel Code,Section XI, 1986 Edition through 2001 Edition, 2003 Addenda, as applicable.

ER-AA-335-1002, Nondestructive Examination Training RM-AA-101, Records Management Program Standard Records Retention Schedule ATTACHMENTS - Minimum Training Requirements for NDE Levels I & 11:

Table I T - Visual Methods; Table 2T - Surface Methods; Table 3T - Volumetric Methods. - Minimum Experience Requirements for NDE Levels I & II:

Table I

- Visual Methods; Table 2E - Surface Methods; Table 3E - Volumetric Methods. - Minimum number Examination Questions for NDE Levels I 8 11. - NDE Certification Records:

Certification Record - Levels I & II; Certification Record - Level Ill; Continued Certification Record. - Supplemental Qualification Requirements for ASME Section XI, Ultrasonic Examination Personnel. - Alternate Qualification of VT-2 Examination Personnel. - Administration of a Vision Examination. - Documentation of Initial NDE Experience and Training.

TQ-AA-I 22 Page 20 of 52 Revision I

ATTACHMENT I Minimum Training Requirements for NDE Levels I & !I Page 1 of 3 Table I T - Visual Methods NDE Level I VT-1, 2, & 3 8 Hours Level II 12 Hours VT-1 3 Hours 4 Hours VT-1 B I

Hour 1 Hour 2 Hours 2 Hours VT-1 C VT-IWI 2 Hours 2 Hours VT-2 2 Hours 2 Hours 5 Hours 6 Hours VT-3 2 Hours 2 hours2.314815e-5 days <br />5.555556e-4 hours <br />3.306878e-6 weeks <br />7.61e-7 months <br /> VT-3c 2 Hours 2 Hours VT-3s Individuals being certified directly to Level II, with no time at Level I, are required to meet the sum of the training time for Level I and Level II for the method.

  • NOTE - VT-I, 2, & 3 are contained in a comprehensive course covering all aspects of Visual Examination. It includes all topics covered by each of the limited Visual Examination subdivisions listed above.

TQ-AA-122 Page Revision 21 of 52 I ATTACHMENT 1 Minimum Training Requirements for NDE Levels I & I1 Page 2 of 3 Table 2T - Surface Methods NDE Level I PT a HOWS PT-L 4 Hours MT 12 Hours MT-L a Hours Level ll 8 Hours 4 Hours 8 Hours 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> Individuals being certified directly to Level 11, with no time at Level I, are required to meet the sum of the training time for Level I and Level II for the method.

TQ-AA-122 Page Revision 22 of 52 I ATTACHMENT 1 Minimum Training Requirements for NDE Levels I & II Page 3 of 3 Table 3T - Volumetric Methods NDE Level I Level I I UT 40 Hours 40 Hours UT-L 20 Hours 20 Hours UT-M 8 Hours 8 Hours RT RT-I ET ET-A 40 Hours 8 Hours 12 Hours 10 Hours 40 Hours 24 Hours 40 Hours 24 hours2.777778e-4 days <br />0.00667 hours <br />3.968254e-5 weeks <br />9.132e-6 months <br /> Individuals being certified directly to level II, with not time at Level I, are required to meet the sum of the training time for Level I and Level II for the method.

TQ-AA-I 22 Page 23 of 52 Revision I ATTACHMENT 2 Minimum Experience Requirements for NDE Levels I & II Page 1 of 3 Table 1 E - Visual Methods Method Hours Method Hours

/ NDE Hours

/ NDE Hours NDE Level I VT-1, 2, & 3*

65 I 130 VT-1 25 150 VT-1 B 10 120 Level It 130 1270 50 1100 20 I40 VT-1 c 10 120 20 I40 VT-IWI 10 120 20 / 40 VT-2 15130 30 I70 VT-3 25 I 5 0 50 / 100 VT-3C VT-3s I O 120 I O 120 20 I 40 20 I 40 Notes: I)

Individuals being certified directly to Level II, with no time at level I, are required to meet the sum of the experience time for Level I and Level II for the method.

2) While fulfilling total NDE experience requirement, experience may be gained in more than one method. Minimum experience hours must be met for each method.
3) * - Experience for simultaneous certification in VT-1, 2, & 3 includes all aspects of visual examination, and is not limited by specific minimums for any particular VT technique.

TQ-AA-I22 Page 24 of 52 Revision I

ATTACHMENT 2 Minimum Experience Requirements for NDE Levels I & II Page 2 of 3 Table 2E - Surface Methods Method Hours Method Hours

/ NDE Hours

/ NDE Hours NDE Level I level I1 PT 65 / 130 135 I270 PT-L 20 / 65 65 / 130 MT 65 I130 200 1400 MT-L 35 I65 75 I150 Notes: I)

Individuals being certified directly to Level II, with no time at level I, are required.to meet the sum of the experience time for Level I and Level II for the method.

2) While fulfilling total NDE experience requirement, experience may be gained in more than one method. Minimum experience hours must be met for each method.

TQ-AA-122 Page 25 of 52 Revision I

ATTACHMENT 2 Minimum Experience Requirements for NDE Levels I & I1 Page 3 of 3 Table 3E - Volumetric Methods Method Hours Method Hours

/ NDE Hours

/ NDE Hours NDE UT UT-L UT-M RT RT-I ET ET-A Level I 200 1400 501 100 20 I 50 200 I 400 25 I50 65 I130 N/A Level II I

a0 I 1200 100 I 400 50 I100 600 I 1200 75 1200 600 I 1200 300 / 600 Notes: 1) Individuals being certified directly to Level II, with no time at level I, are required to meet the sum of the experience time for Level I and Level II for the method.

2) While fulfilling total NDE experience requirement, experience may be gained in more than one method. Minimum experience hours must be met for each method.

NDE vT-1,2, & 3*

VT-1 VT-I B VT-1 C VT-IWI VT-2 VT-3 VT-3c VT-3s PT MT PT-L MT-L UT UT-L UT-M RT RT-I ET TQ-AA-I 22 Page 26 of 52 Revision3 I ATTACHMENT 3 M in i m u m N umber of Ex am i n at i on Quest ions Page 1 of I General 30 20 I O 10 20 I O 20 10 15 30 15 30 15 40 15 10 40 20 40 LEVEL I Specific 20 10 10 10 20 10 10 10 15 20 10 20 I O 20 15 10 20 20 30 General 40 10 10 10 20 I O 20 10 15 30 15 30 15 40 15 10 40 20 40 LEVEL II Specific 25 10 10 10 20 I O 20 I O 15 15 10 15 I O 20 15 10 20 20 20 Note: * - Examinations for simultaneous certification in VT-I, 2, & 3 shall cover all aspects of visual examination technology. Questions shall be randomly selected from a data-bank, and shall include questions covering VT-l, VT-2, and VT-3.

TQ-AA-I 22 Page Revision 27 of 52 I Nuclear ATTACHMENT 4 Certification Record - Level I & Level II Page 1 of 3 NDE CERTIFICATION NAME:

METHOD and LEVEL:

EXPERIENCE PREVIOUS NDE EXPERIENCE:

TRAINING HOURS:

PROVIDED BY or INSTRUCTOR:

GRADE:

EXAMINATION GRADES GENERAL:

SPECIFIC:

PRACTICAL:

AVERAGE:

CERTIFICATION

[ J Initial or [ J Requal.

DATE of CERTIFCATION:

EXPIRATION DATE:

The candidate has successfully completed training, experience and testing for certification to the employer's written practice, TQ-AA-122, latest revision.

CERTIFIED BY:

Print 1 Sign 1 Date Exelon Principal NDE Level 111

TQ-AA-122 Page 28of 52 Nuclear NDE CERTIFICATION NAME:

METHOD and LEVEL:

EXPERIENCE PREVIOUS NDE EXPERIENCE:

rRAlNlNG HOURS:

PROVIDED BY or INSTRUCTOR:

GRADE:

EXAMINATION GRADES METHOD SPECIFIC PRACTICAL DEMO AVERAGE BASIC ASNT Lllll Certificate No.

(if applicable)

CERTIFICATION

[ ] Initial or [ ] Requal.

DATE of CERTIFCATION:

EXPIRATION DATE:

The candidate has successfully completed training, experience and testing for certification to the employers written practice, TQ-AA-122, latest revision.

CERTIFIED BY:

Print / Sign / Date Exelon Principal NDE Level 111

TQ-AA-I 22 Page Revision 29 of 52 I ATTACHMENT 4 Continued Certification Record Page 3 of 3 C 0 N TI N U E D C E RTI F I CAT IO N RE C 0 R D Annual Review Date Vision Acuity Examination Date I

Nuclear 1

New Annual Review Due Date NAME:

NDE METHOD LEVEL:

EXPIRATION DATE:

NDE LEVEL 111 EVALUATION 0

R Current:

All requirements for maintaining this certification have been met.

The individual shall have continual satisfactory service - meaning the individual has performed examinations, or related duties (reviewed or generated procedures, drawings, work scope or participated in the review or supervision of the examinations), in the certified method(s) during the recent past twelve month period.

Suspended:

The requirements for maintaining the certification have not been met due to:

0 Vision Acuity Examination Record not current.

0 No performance of NDE examinations or related duties.

Not applicable to VT-2 certifications in accordance with Code Case N-546.

TerminatedlExpired: Certification voluntarily terminated and/or expiration date has been exceeded.

Revoked:

Reason IR Number:

See Certification Record (Level I, I1 or 111).

Reinstated:

NDE Level 111 Acceptance /

Date:

I

TQ-AA-122 Page Revision 30 of 52 I

1.

1.1.

ATTACHMENT 5 Supplemental Qualification Requirements for ASME Section XI, Ultrasonic Examination Personnel Page 1 of 7 Purpose To establish supplemental requirements for qualification and certification of personnel who perform ultrasonic examinations to fulfill the requirements of ASME Section XI, Appendix VII.,1.1.1. In conjunction with the base document, TQ-AA-122, this attachment I meets or exceeds the requirements of the referenced editions of ASME Section XI, Appendix VII.

1.I

.2. Personnel certified to this attachment shall fulfill all certification requirements for the appropriate level (i.e.; I, II, or 111) of ultrasonic examination (UT) of the base document, TQ-AA-122.

1.I

.3. Where requirements contained in this attachment conflict with those in the base document, TQ-AA-122, such as training hours, the more stringent requirements contained herein shall apply.

2.

Terms and Definitions 2.1.

Same as base document, TQ-AA-122

3.

Responsibilities 3.1.

Same as base document, TQ-AA-I22

4.

Main Body 4.1.

Personnel Qualification 4.1.I. Same as base document, TQ-AA-122 4.2.

Education, Traininq, and Experience 4.2.1. Candidates for certification shall complete sufficient organized initial training to become thoroughly familiar with the theories, principles, and practices of ultrasonic examination.

This training shall, as a minimum, cover the topics listed in the training outlined attached as ER-AA-335-1002.

1.
2.

TQ-AA-122 Page 31 of 52 Revision I

ATTACHMENT 5 Supplemental Qualification Requirements for ASME Section XI, Ultrasonic Examination Personnel Page 2 of 7 Minimum initial training hours for both classroom and laboratory shall be as follows:

INITIAL TRAINING HOURS (Classroom / Laboratory)

Level I Level II 40 / 40 40 / 40 Level Ill 4 0 / 0 General Notes:

a.

To certify a candidate directly to Level II with no time at Level I, the total hours of training required for Level I plus Level II shall apply.

b.

To certify a candidate directly to Level Ill with no time at Level I or Level II, the total hours of training required for Level I plus Level II plus Level Ill shall apply.

C.

for Level Ill personnel.

Industrial or academic training courses covering the topics listed of ER-AA-335-1002 may be credited toward the training required

d.

The hours of instruction devoted to each subject in ER-AA-335-1002 shall be determined by the NDE Instructor.

For individuals who have been previously qualified to Level I or Level II under a written practice that did not include the additional requirements of Appendix VII, additional training shall be required prior to requalification if the individual has not completed the cumulative hours of training in the ultrasonic method required by the above chart for the applicable Level of qualification.

a.

The individuals training, including the additional training required in 4.2.1.2, shall cover the topics listed in the ER-AA-335-1002 for the applicable Level of qualification.

b.

Prior documented training that addressed the topics covered in ER-AA-335-1002 may be credited for each individual. The credited training shall be subtracted from the requirements of the above chart and ER-AA-335-1002 to determine the hours and topics, respectively, to be covered in additional training. An NDE Instructor shall conduct the additional training.

3.

If a qualification examination for certification is not given at the conclusion of training, a final course examination shall be given. A grade of 70% is necessary to receive credit for the training hours.

4.

If an individual fails a final course examination, additional remedial training is required prior to reexamination. The additional training shall address the areas of weakness exhibited by the individual and shall be documented by the NDE lnst ructor.

TQ-AA-122 Page Revision 32 of 52 I ATTACHMENT 5 Supplemental Qualification Requirements for ASME Section XI, Ultrasonic Examination Personnel Page 3 of 7 4.2.2. Each certified individual shall receive a minimum of I O hours of supplemental training each year. This training shall convey knowledge of new developments, material failure modes, and other technical topics pertinent to Exelons NDE program. A record of attendance and the topics covered during the training shall be maintained. No examination is required.

I. As an alternate to the annual training requirements described above, individuals who are Appendix Vlll (PDI) qualified may utilize the semi-annual, 8 hours9.259259e-5 days <br />0.00222 hours <br />1.322751e-5 weeks <br />3.044e-6 months <br /> of hands-on practice from the PDI Program to fulfill all Appendix VI1 annual training requirements. This is described in ASME Code Case N-583. This alternate is only applicable for use at plants, which have received permission to use this alternate.

4.2.3. The minimum experience time, in hours, required for initial certification to each level shall be as follows:

Required Experience for Initial Certification for Ultrasonic Examination (Hours)

Level I Level II Level Ill 250 800 4,200 / 2,100 (Option I )

6,300 / 4,200 (Option 2) 8,400 / 4,200 (Option 3)

General Notes:

a.

For Level II certification, the experience shall consist of time at Level 1.

To certify a candidate directly to Level I1 with no time at Level I, the total experience hours for Level I plus Level I I shall apply When exercising the option for Level 111 (e.g., Option 1: 4200 /2100),

the first figure specifies the required total experience. The second figure specifies the amount of experience that shall be in nuclear applications.

Prior certification as a Level I or Level I I is not required.

b.
1.

The three experience options identified in 4.2.3 for initial Level Ill certification are as follows:

a.

OPTION I

- Graduate of a 4 year accredited engineering or Science College or university with a degree in engineering or science, plus 2 years experience in NDE in an assignment comparable to that of an NDE Level II in the ultrasonic examination method. At least I year of this experience shall be in nuclear applications and shall include the actual performance of examinations and the evaluation of examination results.

4.3.

4.3.1.

4.4.

4.4.1.

4.4.2.

TQ-AA-I22 Page 33 of 52 Revision I

ATTACHMENT 5 Supplemental Qualification Requirements for ASME Section XI, Ultrasonic Examination Personnel Page 4 of 7

b.

OPTION 2 - Completion with a passing grade of at least the equivalent of 2 full years of engineering or science study at a university, college, or technical school, plus 3 years experience in an assignment comparable to that of a Level II in the ultrasonic examination method. At least two years of this experience shall be in nuclear applications and shall include the actual performance of examinations and evaluations of examination results.

c.

OPTION 3 - High school graduate, or equivalent, plus 4 years experience in an assignment comparable to that of Level II in ultrasonic examination method. At least 2 years of this experience shall be in nuclear applications and shall include the actual performance of examinations and evaluation of examination results.

Visual Acuitv Examination Same as base document, TQ-AA-122 N D E Qualification Examination For each written examination administered as part of the qualification examination, a question bank containing at least twice the minimum number of questions required per examination shall be available. Qualification examinations shall be assembled from the question bank using a random selection process.

For each Practical Examination that does not use specimens prepared for UT performance demonstration (i.e., Appendix VIII) and is administered as part of the qualification examination, a specimen bank containing at least five flaws shall be available. Grading units as defined in Appendix VIII, may be used to produce the specimen bank. The flaws in the specimen bank shall be simulated flaws not exceeding the standards of ASME Section XI, IWB-3500, actual fiaws, or a mixture of both. The specimen or grading unit set for each Practical Examination shall be assembled from the specimen bank using a random selection process. Blank (unflawed) test specimens shall be included in the specimen set so that no more than one-third of the specimens or grading units in the set contain flaws required to be detected. The specimens or grading units shall be masked such that flawed and blank specimens or grading units cannot be identified and the flaw locations are not visible.

1.

The specimen set assembled for each practical examination shall not contain specimens, which had been used by the candidate(s) for training.

TQ-AA-122 Page Revision 34 of 52 I ATTACHMENT 5 Supplemental Qualification Requirements for ASME Section XI, Ultrasonic Examination Personnel Page 5 of 7 4.4.3. Level I and Level II General Examinations

1.

The General examination shall be a written, closed book examination containing a minimum 40 questions. The examination shall cover the technical principles relative to the ultrasonic (UT) method.

4.4.4. Level I and Level II Specific Examinations I. The Specific Examination shall be a written examination containing a minimum of 40 questions. Necessary data such as graphs, tables, specifications, procedures, and Codes shall be furnished.

2.

Forty to 60% of the specific examination questions shall cover Section XI NDE requirements. The remaining questions shall cover procedures and specifications applicable to the UT method..

4.4.5. Level I and Level II Practical Examination

1.

Candidates shall demonstrate to the satisfaction of a Level Ill that they are familiar with and can perform the applicable UT examinations using suitable calibration blocks and written UT procedures prepared for examination of plant components.

2.

The practical examination shall include examination of a specimen set that complies with Paragraph 4.4.2 of this attachment.

3.

An assessment report containing at least ten checkpoints shall be used to evaluate the candidates performance using longitudinal and shear wave techniques. The following check points shall be included:

a.

scanning technique;

b.

equipment set-up and calibration;

c.

selection of search unit;

d.
e.

NDE report (Level 11);

f.

data recording (Level I and 11);

evaluation in terms of the recording criteria.

4.

A description of the specimens and the calibration blocks, the procedures used, the assessment report, and the examination report prepared by the candidate shall be retained as part of the certification records.

5.

Alternately, successful completion of an UT performance demonstration in accordance with ASME Section XI, Appendix Vlll (Le., PDI) may serve as this Practical Examination and fulfill all requirements of paragraph 4.4.5.

TQ-AA-I 22 Page Revision 35 of 52 I ATTACHMENT 5 Supplemental Qualification Requirements for ASME Section XI, Ultrasonic Examination Personnel Page 6 of 7 4.4.6. Level Ill Qualification Examinations

1.

The Level Ill Examinations shall be in accordance with the requirements of the base document, TQ-AA-122 except:

a.

The Demonstration Examination shall meet the requirements for the Level II Practical Examination in paragraph 4.4.5 of this Attachment.

b.

The Specific Examination shall be at least 30 questions. Forty to 60% of the questions shall cover Section XI UT examination, evaluation, and acceptance criteria.

c.

The Basic and Method Examination shall be administered and graded by an outside agency.

d.

The Specific, Practical, and Demonstration Examinations shall be approved, administered, and graded by a Level I l l employed by an outside agency or Exelon.

4.4.7. Grading of Examinations

1.

A passing grade of 80% is required for each examination.

2.

The Level I and II Practical Examinations and the Level Ill Demonstration Examination shall be graded such that failure to accurately detect, locate, interpret, evaluate, or record, as applicable for the examination, 80% of the known conditions in the test specimen set shall cause the candidate to fail the examination. In addition, a maximum false call rate of 10% shall be imposed.

(i.e., no more than 10% of the blank test specimens shall be reported as flawed).

4.4.8. Reexamination

1.

Those individuals failing to pass a qualification examination shall receive additional training as determined by a Level 111. This determination shall be based on the topics or subjects on which the individual failed to obtain a passing grade.

2.

No individual shall be administered the same written examination more than once. Each reexamination, whether due to an insufficient grade or routine requalification, shall be selected at random and shall contain a minimum of 40%

new or revised questions.

TQ-AA-122 Page Revision 36 of 52 I ATTACHMENT 5 Supplemental Qualification Requirements for ASME Section XI, Ultrasonic Examination Personnel Page 7 of 7

3.

The Practical or Demonstration Examination test specimen set shall contain at least 50% different flaws from those used during the most recent Practical or Demonstration Examination that was not passed by the candidate.

4.

No individual shall be reexamined more than twice within any consecutive 12 month period.

4.4.9. Interrupted Service

1.

Personnel who have not performed the duties associated with their certification level during any consecutive 12 month period shall be considered to have interrupted service and shall be required to successfully complete a Practical Examination (Level I and II personnel) or Specific Examination (Level Ill personnel) to assure continued proficiency prior to further assignment to perform NDE. The results of this examination shall be documented and maintained as part of the individuals certification record.

5.

Documentation 5.1.

The following additional information shall be maintained in an individuals certification record to satisfy the requirements of this

Attachment:

5.1.I.

Educational background of the individual 5.1.2. Record of annual supplemental training 5.1.3. Description of the specimens and calibration blocks, the procedures used, the assessment report, and the examination report prepared by the candidate for the Practical Examination (Level I and II) or the Demonstration Examination (Level 111)

6.

Reference 6.1.

ASME Code Case N-583, Annual Training Alternative

7.

Attachments 7.1.

None

TQ-AA-122 Page Revision 37 of 52 I ATTACHMENT 6 Alternate QualificationlCertification of VT-2 Ex-mination Personnel Page 1 of 5

1.

1.1.

1.2.

1.3.

2.

2.1.

2.2.

2.3.

3.

3.1.

4.

4.1.

4.1.1 Purpose To establish the requirements for qualificationlcertification of personnel in accordance with ASME Section XI and Code Case N-546, Alternate Requirements for Qualification of VT-2 Examination Personnel.

This qualification/certification is specific to a Station only and should not be transferred between Stations unless there is an approved SER covering multiple stations.

This attachment applies to all Exelon Personnel who perform VT-2 examinations, other than those qualified and certified in accordance with the base document, TQ-AA-122.

Personnel who are certified Level I1 or Level Ill in VT-2, in accordance with the base document fulfill all requirements of this attachment.

Terms and Definitions Qualification - The characteristics or abilities gained through education, training, and experience, as measured against established requirements, such as standards or tests that verify an individuals ability to perform a required function.

Visual Testinq - (VT-2) - The observation to locate evidence of leakage from pressure retaining components, or abnormal leakage from components with or without leakage collection systems, during a system pressure or functional test.

NDE Level Ill - An individual certified Level Ill in VT-2 in accordance with the base document, TQ-AA-122.

Responsibilities Same as base document, TQ-AA-122.

Main Body Personnel Qualification Same as base document, TQ-AA-122.

4.1 2. VT-2 Level II shall be the only level of qualification.

TQ-AA-I 22 Page Revision 38 of 52 I ATTACHMENT 6 Alternate QualificationlCertification of VT-2 Examination Personnel Page 2 of 5 4.1.3. While in the process of being qualified to VT-2 Level II, an individual shall be considered a Trainee. A Trainee shall work under the direction of a qualified individual and shall not independently conduct any tests, interpret or evaluate the results of a test, or report test results.

4.1.4. VT-2 Level II personnel shall be qualified to: perform examinations; set-up and calibrate equipment; interpret or evaluate results with respect to applicable codes, standards, and specifications; and organize and report on examinations. VT-2 Level II personnel shall be thoroughly familiar with the scope and limitations of the examination method and shall exercise assigned responsibility for on-the-job training of Trainee personnel.

4.2.

Trainincl and Experience 4.2.1 This qualification is in accordance with the specific Station Program plans.

4.3.

Visual Acuitv Examination 4.3.1. Same as base document, TQ-AA-122 4.4.

Qualification Examination 4.4. I.

This qualification is in accordance with the specific Station Program plans.

I 4.5. Grading 4.5.1. A candidate shall score a minimum grade of 80% or greater to be considered for qualification.

4.6.

Reexamination 4.6.1. Personnel who fail to attain the required minimum grade on the qualifying examination may be reexamined after waiting at least one month or after having received suitable additional training as determined by the NDE Level I l l.

4.7.

Expiration 4.7.1. This certification is in accordance with the specific Station Program plans.

TQ-AA-I 22 Page Revision 39 of 52 I ATTACHMENT 6 Alternate QualificationlCertification of VT-2 Examination Personnel Page 3 of 5 4.8.

Requalification 4.8.1. This certification is in accordance with the specific Station Program plans.

4.9.

Suspension 4.9.1. An individuals qualification will be suspended if hidher visual acuity exarl,lial interval exceeds one year.

on

1.

The qualification is automatically reinstated, concurrent with the candidates successful completion of the vision examination.

4.9.2 The individuals performance is determined to be deficient in the required method or technique for specific documented reasons.

4.10. Termination 4.1 0.1. Exelon will terminate an individuals qualification when:

1.

The individual leaves the active employment of Exelon.

5.

Documentation 5.1.

A qualification file shall be maintained for each VT-2 Level II examiner currently qualified in accordance with this attachment. This file shall contain the following information as a minimum:

5.1.I.

Qualification Record, including

1.

Name and Social Security Number (optional) of qualified individual

2.

NDE Method and Level of Qualification (i.e., VT-2, Level 11)

3.

Final examination grade

4.

Date of Qualification

5.

Printed name and signature of Exelon authorized qualifying individual

TQ-AA-122 Page Revision 40 of 52 I ATTACHMENT 6 Alternate QualificationlCertification of VT-2 Examination Personnel Page 4 of 5 5.1.2. Training Documentation I. Evidence of satisfactory completion of the required classroom training. This may include course certificates, attendance sheets, etc., but must include dates and duration of applicable training, identification of organization providing training, name of instructor, and evidence of satisfactory completion.

5.1.3. Experience Documentation I.

Evidence of sufficient applicable plant or related experience to support qualification. This may include verified experience from previous employers, previous Exelon certification, experience logs, etc.

5.1.4. Visual Acuity Results

6.

6.1.

6.2.

7.

7.1.

1.

References Same as base document, TQ-AA-122.

ASME Code Case N-546, Alternate Requirements for Qualification of VT-2 Examination Personnel.

Attachments Exhibit 1 - VT-2 Qualification Record Evidence of current, satisfactory visual acuity examination.

TQ-AA-122 Page Revision 41 of 52 I ATTACHMENT 6 Alternate QualificationlCertification of VT-2 Examination Personnel Page 5 of 5 EXHIBIT 1 - VT-2 CERTIFICATION RECORD Nuclear VT-2 CERTIFICATION NAME:

The individual named above is qualified as a Level I1 Examiner in Visual Testing-2 (VT-2). This certification is in accordance with the alternate requirements for qualification of VT-2 Examination personnel established in TQ-AA-122 and ASME Boiler and Pressure Vessel Code Case N-546.

METHOD and LEVEL:

VISUAL TESTING (VT-2) - Level II APPLICABLE PLANT 8t NDE EXPERIENCE:

TRAINING:

HOURS:

INSTRUCTOR:

GRADE:

DATE of CERTIFICATION:

EXPIRATION DATE:

CERTIFIED BY:

Exelon NO VT-2 Level 111

TQ-AA-122 Page 42 of 52 Revision I

1.

1.1.

1.2.

I

.3.

2.
3.

3.1, 3.1.I 3.1.2 3.2.

3.3.

4.

4.1.

ATTACHMENT 7 Administration of a Vision Examination Page I of 6 Purpose To establish requirements and administrative controls to verify and document natural or corrected near distance visual acuity, far distance visual acuity, and color contrast vision.

This Attachment fulfills the requirements of ASME Boiler and Pressure Vessel Code,Section XI (1 998 and earlier Editions), ASNT SNT-TC-1A (through 1984 Edition) and ANSVASNT CP-189 (1 991/1995 Edition) for visual acuity verification This Attachment applies to all certified Exelon and Amergen personnel who perform nondestructive examinations required by Standards, Codes, or Procedures. It may also be used to verify the visual acuity of vendor NDE personnel.

Terms and Definitions - None Responsibilities NDE level Ill or his desiqnated representative is responsible for:

Administration of near distance visual acuity, far distance visual acuity, and color contrast examinations.

Completion of Visual Acuity Verification form, Exhibit 1 to this Attachment, for all personnel completing the visual examination.

The NDE Level Ill is responsible for:

I. Indoctrination of designated individuals who may administer vision examinations to this Attachment. Such indoctrination shall be documented on the Designated Examiner Indoctrination form, Exhibit 2 to this Attachment Licensed medical professionals, i.e., Physician, Registered Nurse, Physicians Assistant, etc., may also administer these examinations. Medical personnel do not require the indoctrination described in 3.2.1.

Main Body Prerequisites 4.1.I.

Equipment

TQ-AA-122 Page Revision 43 of 52 I ATTACHMENT 7 Administration of a Vision Examination Page 2 of 6 I. A near distance test chart, such as a Jaeger Chart or equivalent, meeting the following qualification requirements:

a.

A measurement of test chart characters shall be made once before initial use, with an optical comparator (1 OX or greater) or other suitable instrument, to verify that the height of a representative lower case character, without an ascender or descender (i.e., a, c, e, o,), is within the range of Table 1. This measurement shall be documented and traceable to the test chart.

TABLE I Test Distance tin.)

12 13 14 15 16 Max. Lower Case Character Ht. {in) 0.022 0.024 0.025 0.027 0.029 Note:

The test distance (eye to chart) and corresponding character heights provide a visual angle of 6.25 minutes, which is equivalent to a Snellen fraction of 20t25.

2.

lshihara color contrast plates, or equivalent.

3.

A standard Snellen test chart, or equivalent 4.2.

Instructions 4.2.1. Vision examinations shall be administered to the individual in well-lighted surroundings.

4.2.2. Personnel shall demonstrate natural or corrected near-distance acuity of 20/25 or greater Snellen fraction, with at least one eye by reading the words or identifying characters on a near distance test chart described in 4.1.1.I.

The chart shall be used at a minimum distance appropriate for the measured character size of the chart.

1.

Other tests which yield an equivalent measure of near distance acuity may be used.

4.2.3. Personnel performing visual examinations shall demonstrate natural or corrected dar-distance acuity at a distance of 20 feet, of 20/30 or greater Snellen fraction or equivalent with at least one eye.

TQ-AA-122 Page Revision 44 of 52 I ATTACHMENT 7 Administration of a Vision Examination Page 3 of 6 4.2.4. Personnel shall demonstrate the capability to distinguish the colors applicable to the NDE methods for which certified and to differentiate contrast between these colors. If lshihara Color Contrast Plates are used, they shall be viewed at a distance of less than 30 inches.

1.

A deficiency in the ability of an individual to distinguish contrast or color shall be noted on the test record. The NDE examiners ability to perform and pass the practical examinations is satisfactory evidence to distinguish contrast.

4.2.5. Based on the results of the individuals vision examination, the applicable test results box on the visual acuity verification form (Exhibit 1 to this Attachment) shall be marked, and the form signed by the vision examiner.

4.2.6. Individuals may be re-evaluated at any time, at the discretion of their supervision or the NDE Level Ill, to assure an individuals continued ability to meet the minimum requirements.

4.3.

Effective Period 4.3.1. The effective period of vision certification shall be for a maximum of one year

5.

Documentation 5.1.

A written report shall be completed for each vision examination administered and shall include at least the following; being tested.

5.1.I. Identification, including name and social security number (optional), of the individual 5.1.2. Chart number or other identification, traceable to the initial measurement of the test characters.

5.1.3. The vision examination requirements.

5.1.4. Examination test results, which shall note whether the individual requires eye correction.

5.1.5. Date of examination 5.1.6. Identification of the NDE Level Ill, designated representative, or licensed medical person administering the examination.

5.2.

The Visual Acuity Verification form, Exhibit 1 to this Attachment, may be used to fulfill the requirements of Section 5.1 and subsequent subsections of this Attachment. Other vision forms may be used provided the minimum information above is recorded.

TQ-AA-122 Page Revision 45 of 52 I ATTACHMENT 7 Administration of a Vision Examination Page 4 of 6 5.3.

When an NDE Level Ill provides indoctrination to a designated representative in the administration of visual acuity examinations it shall be documented and shall include the following information as a minimum:

5.3.1. Printed name and signature of the Designated examiner 5.3.2. Date of indoctrination 5.3.3. Signature of NDE Level Ill providing the indoctrination.

5.4.

6.

6.1.

6.2.

6.3.

7.

7.1.

7.2 The Designated Examiner Indoctrination form, Exhibit 2 to this Attachment, may be used to fulfill the requirements of Section 5.3 and subsequent subsections of this Attachment.

References Same as base document, TQ-AA-122.

American Society for Nondestructive Testing, Recommended Practice, SNT-TC-1 A, Personnel Qualification and Certification in Nondestructive Testing (through 1984 Edition)

ANSVASNT CP-189 Standard for Qualification and Certification of Nondestructive Testing Personnel (1 991 and 1995 Edition)

Attachments EXHIBIT 1 - Visual Acuity Verification Form EXHIBIT 2 - Designated Examiner Indoctrination Form

TQ-AA-I22 Page Revision 46 of 52 I ATTACHMENT 7 Administration of a Vision Examination Page 5 of 6 EXHIBIT 1 - VISUAL ACUITY VERIFICATION FORM Visual Acuity Verification For NDE Examiners NAME:

DATE:

CHART NO.:

The above individual was examined on the above date for visual acuity. This Examination fulfils the minimum requirements defined in Exelon Procedure ##

TQ-AA-I 22, and verified the following qualifications:

1.

Natural or corrected near distance acuity, in at least one eye, of 20/25 or greater Snellen fraction.

2.

The ability to distinguish colors applicable to the NDE method and to differentiate contrast between these colors.

3.

eye, of a Snellen fraction of 20130 or equivalent.

Natural or corrected far distance acuity, in at least one TEST RESULTS

[ J Individual meets requirements without correction

[ J Near Vision

[ J Far Vision

[ J Individual meets requirements, but must use correction for;

[ J Near Vision

[ J Far Vision

[ )

Individual does not meet requirements This Verification expires:

Examination Administered By:

Comments / Deficiencies:

TQ-AA-122 Page

.Revision 47 of 52 I ATTACHMENT 7 Administration of a Vision Examination Page 6 of 6 EXHIBIT 2 - DESIGNATED EXAMINER INDOCTRINATION FORM Visual Acuity Designated Examiner Indoctrination Name:

Date:

The individual named above received indoctrination in the requirements for the administration of a vision examination on this date. This indoctrination required the designated examiner to demonstrate, to the NDE Level 111, his / her ability to administer a vision examination meeting the requirements of TQ-AA-I 22, and in accordance with Attachment 7 of that Procedure.

Signature of NDE Level 111:

Signature of Designated Examiner:

TQ-AA-122 Page Revision 48 of 52 I

1.

1.1.

1.2.

2.
3.

3.1.

3.2.

3.3.

4.

4.1.

4.2.

ATTACHMENT 8 Documentation of Initial NOE Experience and Training Page I of 5 Purpose To establish appropriate guidelines and administer controls to assure proper documentation of initial NDE work experience and training.

This attachment provides a method of documenting required NDE experience and Document, TQ-AA-122. Once certification to Level II is successfully completed in a method, the hourly documentation of experience is no longer required.

training used for initial qualification and certification of NDE personnel to the Base I

Terms and Definitions - None Responsibilities NDE Examiners or candidates are responsible for:

1.

Completion of NDE Monthly Experience Record.

2.

Tabulation of applicable hours for specific NDE disciplines and for total NDE experience time.

First line supervisors (if applicable) of NDE Examiners or Candidates are responsible for:

1.

Review and approval of completed NDE Monthly Experience Record for subordinate personnel.

NDE Level Ill is responsible for:

1.

Review of completed and approved NDE monthly experience records.

2.

Completing the Experience Verification / Validation Record for initial certification.

Main Body NDE Examiners and candidates shall enter each days applicable NDE work experience on the NDE Monthly Experience Record, Exhibit 1 to this Attachment, or equivalent and forward completed forms to their supervisor and NDE Level Ill for review and approval.

The following are examples of specific NDE related job duties for that may be claimed as NDE experience and which will be credited towards required totals for NDE certification:

1.

Actual field and lab experience in the performance of NDE examinations.

TQ-AA-122 Page Revision 49 of 52 I 4.3.

4.3.1

5.

5.1.

2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.

14

15.

ATTACHMENT 8 Documentation of Initial NDE Experience and Training Page 2 of 5 Preparing, instructing, or assisting in the instruction of NDE training classes.

Reviewing data packages from previous NDE examinations.

Writing or revising NDE procedures.

Demonstrating and qualifying NDE procedures.

Reviewing I interpreting Code requirements.

Reviewing / preparing drawings and sketches pertaining to NDE equipment, calibration blocks, examination areas, etc.

Building / designing NDE equipment and other related examination material.

Performing tests and examinations to determine the feasibility of various NDE methods and equipment.

Operating equipment for mechanized NDE.

Calibration or verification of NDE.

Installing and removing mechanized NDE devices.

Writing NDE Plans.

Monitoring / oversight of NDE Contractor Services.

Preparing reports related to NDE.

Attendance at training in a specific NDE discipline shall not be claimed as NDE experience toward certification in that discipline, but may be included toward the total NDE experience required.

Such training time shall be entered on the appropriate space on the experience record and shall be followed by a (T), denoting it as training time. This time shall not be added to the specific method / discipline accrual total for certification in that method but may be included in the overall total NDE experience hours.

Documentation Completed NDE Monthly Experience Records, Exhibit 1 to this Attachment, or equivalent shall be kept in the individuals certification file.

TQ-AA-I 22 Page Revision 50 of 52 1 ATTACHMENT 8 Documentation of Initial NDE Experience and Training Page 3 of 5

6.

References I

6.1.

American Society for Nondestructive Testing, Recommended Practice, SNT-TC-1 A, Personnel Qualification and Certification in Nondestructive Testing (through 1984 Edition).

6.2.

ANSVASNT CP-189, Standard for Qualification and Certification of Nondestructive Testing Personnel (1991 and? 995 Edition).

6.3. ASME Boiler and Pressure Vessel Code,Section XI, Same as Base Document I

7.

Attachments 7.1.

EXHIBIT I - NDE Monthly Experience Record 7.2. EXHIBIT 2 - Experience Verification / Validation Record

TQ-AA-I 22 Page Revision 51 of 52 I ATTACHMENT 8 Documentation of Initial NDE Experience and Training Page 4 of 5 EXHIBIT 1 - NDE MONTHLY EXPERIENCE RECORD NDE Monthly Experience Record Name:

Month:

Year:

HOURS DATE MT PT RT UT 7

vT-[l, 2,31 METHOD TOTALS:

Supervisor:

NDE Level 111:

TQ-AA-122 Page Revision 52 of 52 I ATTACHMENT 8 Documentation of Initial NDE Experience and Training Page 5 of 5 EXHIBIT 2 - EXPERIENCE VERIFICATION / VALIDATION RECORD IName:

Method Level EDUCATION Associates Degree 0 Bachelors Degree High School Diploma or General Education Document (GED)

TRAl N I N G Institution Datels)

Hours/Months EXPERIENCE Em plover Date(s1 HourslMonths

~

STATEMENT The below NDE Level 111 attests to verifying I validating the above information by telephone, mail and/or fax. The verification / validation documents are attached and are a part of the certification file.

~ N D E Level 111:

Date: