Fuel Storage Pool Boron Concentration 3.7.17 SAN ONOFRE-UNIT 2 3.7-30 Amendment No. 213 3.7 PLANT SYSTEMS 3.7.17 Fuel Storage Pool Boron Concentration LCO 3.7.17 The fuel storage pool boron concentration shall be
$ 2000 ppm.
APPLICABILITY:
Whenever any fuel assembly is stored in the fuel storage pool.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.
Fuel storage pool boron concentration not within limit.
NOTE-------------
LCO 3.0.3 is not applicable.
A.1 Suspend movement of fuel assemblies in the fuel storage pool.
AND A.2 Initiate action to restore fuel storage pool boron concentration to within limit.
Immediately Immediately
Spent Fuel Assembly Storage 3.7.18 SAN ONOFRE--UNIT 2 3.7-32 Amendment No. 213 3.7 PLANT SYSTEMS 3.7.18 Spent Fuel Assembly Storage LCO 3.7.18 The combination of initial enrichment and burnup of each SONGS 2 and 3 spent fuel assembly stored in Region I shall be within the acceptable burnup domain of Figure 3.7.18-1 or Figure 3.7.18-2, or the fuel assembly shall be stored in accordance with Technical Specification 4.3.1.1.
The combination of initial enrichment and burnup of each SONGS 2 and 3 spent fuel assembly stored in Region II shall be within the acceptable burnup domain of Figure 3.7.18-3 or Figure 3.7.18-4, or the fuel assembly shall be stored in accordance with Technical Specification 4.3.1.1.
Each SONGS 1 uranium dioxide spent fuel assembly stored in Region II shall be stored in accordance with Technical Specification 4.3.1.1.
APPLICABILITY:
Whenever any fuel assembly is stored in the fuel storage pool.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.
Requirements of the LCO not met.
A.1 --------NOTE---------
LCO 3.0.3 is not applicable.
Initiate action to bring the noncomplying fuel assembly into compliance.
Immediately SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.18.1 Verify by administrative means the initial enrichment, burnup, and cooling time of the fuel assembly are in accordance with LCO 3.7.18, or Design Features 4.3.1.1, or LCS 4.0.100. Rev 2, dated 09/27/07.
Prior to moving a fuel assembly to any spent fuel pool storage location.
Spent Fuel Assembly Storage 3.7.18 SAN ONOFRE--UNIT 2 3.7-33 Amendment No. 213 0
5 10 15 20 25 Fuel Assembly Burnup (GWD/T) 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Initial U-235 Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Acceptable Region Unacceptable Region FIGURE 3.7.18-1 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR UNRESTRICTED PLACEMENT OF SONGS 2 AND 3 FUEL IN REGION I RACKS
Spent Fuel Assembly Storage 3.7.18 SAN ONOFRE--UNIT 2 3.7-34 Amendment No. 213 0
5 10 15 Fuel Assembly Burnup (GWD/T) 3.0 3.5 4.0 4.5 5.0 Initial U-235 Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Acceptable Region Unacceptable Region FIGURE 3.7.18-2 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR PLACEMENT OF SONGS 2 AND 3 FUEL IN PERIPHERAL POOL LOCATIONS IN REGION I RACKS
Spent Fuel Assembly Storage 3.7.18 SAN ONOFRE--UNIT 2 3.7-34a Amendment No. 213 FIGURE 3.7.18-3 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR UNRESTRICTED PLACEMENT OF SONGS 2 AND 3 FUEL IN REGION II RACKS
Spent Fuel Assembly Storage 3.7.18 SAN ONOFRE-UNIT 2 3.7-34b Amendment No. 213 FIGURE 3.7.18-4 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR PLACEMENT OF SONGS 2 AND 3 FUEL IN PERIPHERAL POOL LOCATIONS IN REGION II RACKS
4.0 DESIGN FEATURES (continued)
Design Features 4.0 (continued)
SAN ONOFRE--UNIT 2 4.0-4 Amendment No. 213 4.3 Fuel Storage 4.3.1 Criticality 4.3.1.1 The spent fuel storage racks are designed and shall be maintained with:
a.
Fuel assemblies having a maximum U-235 enrichment of 4.8 weight percent; b.
Keff < 1.0 if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR; c.
Keff # 0.95 if fully flooded with water borated to 1700 ppm, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR; d.
Three or five Borated stainless steel guide tube inserts (GT-Insert) may be used. When three Borated stainless steel guide tube inserts are used, they will be installed in an assembly's center guide tube, the guide tube associated with the serial number, and the diagonally opposite guide tube. Fuel containing GT-Inserts may be placed in either Region I or Region II. However, credit for GT-Inserts is only taken for Region II storage.
A five-finger CEA may be installed in an assembly.
Fuel containing a five-finger CEA may be placed in either Region I or Region II. Credit for inserted 5-finger CEAs is taken for both Region I and Region II.
e.
A nominal 8.85 inch center to center distance between fuel assemblies placed in Region II; f.
A nominal 10.40 inch center to center distance between fuel assemblies placed in Region I;
4.0 DESIGN FEATURES (continued)
Design Features 4.0 (continued)
SAN ONOFRE--UNIT 2 4.0-4a Amendment No. 213 4.3.1 Criticality (continued) g.
Prior to using the storage criteria of LCO 3.7.18 and LCS 4.0.100, the following uncertainties will be applied:
(1) The calculated discharge burnup of San Onofre Units 2 and 3 assemblies will be reduced by 6.6%.
(2) The calculated discharge burnup of San Onofre Unit 1 fuel assemblies will be reduced by 10.0%.
h.
Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-1 are allowed unrestricted storage in Region I; i.
Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-2 are allowed unrestricted storage in the peripheral pool locations with 1 or 2 faces toward the spent fuel pool walls of Region I; j.
Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-3 are allowed unrestricted storage in Region II; k.
Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-4 are allowed unrestricted storage in the peripheral pool locations with 1 or 2 faces toward the spent fuel pool walls of Region II; l.
Units 2 and 3 fuel assemblies with a burnup in the "unacceptable range" of Figure 3.7.18-1, Figure 3.7.18-2, Figure 3.7.18-3, and Figure 3.7.18-4 will be stored in compliance with Licensee Controlled Specification 4.0.100 Rev. 2, dated 09/27/07; and m.
Each SONGS 1 uranium dioxide spent fuel assembly stored in Region II shall be stored in accordance with Licensee Controlled Specification 4.0.100 Rev. 2, dated 09/27/07.
Fuel Storage Pool Boron Concentration 3.7.17 SAN ONOFRE--UNIT 3 3.7-30 Amendment No. 205 3.7 PLANT SYSTEMS 3.7.17 Fuel Storage Pool Boron Concentration LCO 3.7.17 The fuel storage pool boron concentration shall be
$ 2000 ppm.
APPLICABILITY:
Whenever any fuel assembly is stored in the fuel storage pool.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.
Fuel storage pool boron concentration not within limit.
NOTE-------------
LCO 3.0.3 is not applicable.
A.1 Suspend movement of fuel assemblies in the fuel storage pool.
AND A.2 Initiate action to restore fuel storage pool boron concentration to within limit.
Immediately Immediately
Spent Fuel Assembly Storage 3.7.18 SAN ONOFRE--UNIT 3 3.7-32 Amendment No. 205 3.7 PLANT SYSTEMS 3.7.18 Spent Fuel Assembly Storage LCO 3.7.18 The combination of initial enrichment and burnup of each SONGS 2 and 3 spent fuel assembly stored in Region I shall be within the acceptable burnup domain of Figure 3.7.18-1 or Figure 3.7.18-2, or the fuel assembly shall be stored in accordance with Technical Specification 4.3.1.1.
The combination of initial enrichment and burnup of each SONGS 2 and 3 spent fuel assembly stored in Region II shall be within the acceptable burnup domain of Figure 3.7.18-3 or Figure 3.7.18-4, or the fuel assembly shall be stored in accordance with Technical Specification 4.3.1.1.
Each SONGS 1 uranium dioxide spent fuel assembly stored in Region II shall be stored in accordance with Technical Specification 4.3.1.1.
APPLICABILITY:
Whenever any fuel assembly is stored in the fuel storage pool.
ACTIONS CONDITION REQUIRED ACTION COMPLETION TIME A.
Requirements of the LCO not met.
A.1 --------NOTE---------
LCO 3.0.3 is not applicable.
Initiate action to bring the noncomplying fuel assembly into compliance.
Immediately SURVEILLANCE REQUIREMENTS SURVEILLANCE FREQUENCY SR 3.7.18.1 Verify by administrative means the initial enrichment, burnup, and cooling time of the fuel assembly are in accordance with LCO 3.7.18, or Design Features 4.3.1.1, or LCS 4.3.100. Rev 2, dated 09/27/07.
Prior to moving a fuel assembly to any spent fuel pool storage location.
Spent Fuel Assembly Storage 3.7.18 SAN ONOFRE--UNIT 3 3.7-33 Amendment No. 205 0
5 10 15 20 25 Fuel Assembly Burnup (GWD/T) 2.0 2.5 3.0 3.5 4.0 4.5 5.0 Initial U-235 Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Acceptable Region Unacceptable Region FIGURE 3.7.18-1 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR UNRESTRICTED PLACEMENT OF SONGS 2 AND 3 FUEL IN REGION I RACKS
Spent Fuel Assembly Storage 3.7.18 SAN ONOFRE--UNIT 3 3.7-34 Amendment No. 205 0
5 10 15 Fuel Assembly Burnup (GWD/T) 3.0 3.5 4.0 4.5 5.0 Initial U-235 Enrichment (w/o) 0 Years 5 Years 10 Years 15 Years 20 Years Acceptable Region Unacceptable Region FIGURE 3.7.18-2 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR PLACEMENT OF SONGS 2 AND 3 FUEL IN PERIPHERAL POOL LOCATIONS IN REGION I RACKS
Spent Fuel Assembly Storage 3.7.18 SAN ONOFRE--UNIT 3 3.7-34a Amendment No. 205 FIGURE 3.7.18-3 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR UNRESTRICTED PLACEMENT OF SONGS 2 AND 3 FUEL IN REGION II RACKS
Spent Fuel Assembly Storage 3.7.18 SAN ONOFRE--UNIT 3 3.7-34b Amendment No. 205 FIGURE 3.7.18-4 MINIMUM BURNUP AND COOLING TIME VS. INITIAL ENRICHMENT FOR PLACEMENT OF SONGS 2 AND 3 FUEL IN PERIPHERAL POOL LOCATIONS IN REGION II RACKS
4.0 DESIGN FEATURES (continued)
Design Features 4.0 (continued)
SAN ONOFRE-UNIT 3 4.0-4 Amendment No. 205 4.3 Fuel Storage 4.3.1 Criticality 4.3.1.1 The spent fuel storage racks are designed and shall be maintained with:
a.
Fuel assemblies having a maximum U-235 enrichment of 4.8 weight percent; b.
Keff < 1.0 if fully flooded with unborated water, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR; c.
Keff # 0.95 if fully flooded with water borated to 1700 ppm, which includes an allowance for uncertainties as described in Section 9.1 of the UFSAR; d.
Three or five Borated stainless steel guide tube inserts (GT-Inserts) may be used. When three Borated stainless steel guide tube inserts are used, they will be installed in an assembly's center guide tube, the guide tube associated with the serial number, and the diagonally opposite guide tube. Fuel containing GT-Inserts may be placed in either Region I or Region II. However, credit for GT-Inserts is only taken for Region II storage.
A five-finger CEA may be installed in an assembly.
Fuel containing a five-finger CEA may be placed in either Region I or Region II. Credit for inserted 5-finger CEAs is taken for both Region I and Region II.
e.
A nominal 8.85 inch center to center distance between fuel assemblies placed in Region II; f.
A nominal 10.40 inch center to center distance between fuel assemblies placed in Region I;
4.0 DESIGN FEATURES (continued)
Design Features 4.0 (continued)
SAN ONOFRE-UNIT 3 4.0-4a Amendment No. 205 4.3.1 Criticality (continued) g.
Prior to using the storage criteria of LCO 3.7.18 and LCS 4.0.100, the following uncertainties will be applied:
(1) The calculated discharge burnup of San Onofre Units 2 and 3 assemblies will be reduced by 6.6%.
(2) The calculated discharge burnup of San Onofre Unit 1 fuel assemblies will be reduced by 10.0%.
h.
Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-1 are allowed unrestricted storage in Region I; i.
Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-2 are allowed unrestricted storage in the peripheral pool locations with 1 or 2 faces toward the spent fuel pool walls of Region I; j.
Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-3 are allowed unrestricted storage in Region II; k.
Units 2 and 3 fuel assemblies with a burnup in the "acceptable range" of Figure 3.7.18-4 are allowed unrestricted storage in the peripheral pool locations with 1 or 2 faces toward the spent fuel pool walls of Region II; l.
Units 2 and 3 fuel assemblies with a burnup in the "unacceptable range" of Figure 3.7.18-1, Figure 3.7.18-2, Figure 3.7.18-3, and Figure 3.7.18-4 will be stored in compliance with Licensee Controlled Specification 4.0.100 Rev. 2, dated 09/27/07; and m.
Each SONGS 1 uranium dioxide spent fuel assembly stored in Region II shall be stored in accordance with Licensee Controlled Specification 4.0.100 Rev. 2, dated 09/27/07.