NL-07-1354, Request to Implement an Alternative Source Term Response to Request for Additional Information Re the Development of Atmospheric Dispersion Factors

From kanterella
(Redirected from ML072260380)
Jump to navigation Jump to search
Request to Implement an Alternative Source Term Response to Request for Additional Information Re the Development of Atmospheric Dispersion Factors
ML072260380
Person / Time
Site: Hatch  
Issue date: 08/13/2007
From: Stinson L
Southern Nuclear Operating Co
To:
Document Control Desk, Office of Nuclear Reactor Regulation
References
NL-07-1354
Download: ML072260380 (12)


Text

1. M. Stinson (Mike)

Southern Nuclear Vice President Operating Company, Inc.

Fleet Operations Support 40 lnverness Center Parkway Post Office Box 1295 Birmingham. Alabama 35201 Tel 205.992.5181 Fax 205.992.0341 August 13,2007 Docket Nos.: 50-321 50-366 COMPANY Energy to Serve Your World' U. S. Nuclear Regulatory Commission ATTN: Document Control Desk Washington, D. C. 20555-0001 Edwin I. Hatch Nuclear Plant Request to Implement an Alternative Source Term Response to Request for Additional Information Reaardina the Development of Atmospheric Dispersion Factors Ladies and Gentlemen:

On August 29,2006, Southern Nuclear Operating Company (SNC) submitted a request to revise the Edwin I. Hatch Nuclear Plant (HNP) licensingldesign basis with a full scope implementation of an alternative source term (AST). By letters dated November 6,2006, November 27,2006, January 30,2007, June 22,2007, and July 16, 2007, SNC has submitted further information to support the NRC review of the HNP AST submittal. By letter dated May 30, 2007, the NRC requested additional information concerning the development of the atmospheric dispersion factors used in the AST analyses for the main control room and the technical support center. It is noted that no changes have been made to the current licensing basis offsite atmospheric dispersion factors for the AST analyses.

'The enclosure to this letter contains the SNC response to the referenced NRC request for additional information (RAI).

The 10 CFR 50.92 evaluation and the justification for the categorical exclusion from performing an environmental assessment that were included in the August 29, 2006 submittal continue to remain valid.

(Affirmation and signature are on the following page.)

U. S. Nuclear Regulatory Commission NL-07-1354 Page 2 Mr. L. M. Stinson states he is a Vice President of Southern Nuclear Operating Company, is authorized to execute this oath on behalf of Southern Nuclear Operating Company and to the best of his knowledge and belief, the facts set forth in this letter are true.

This letter contains no NRC commitments. If you have any questions, please advise.

Respectfully submitted, SOUTHERN NUCLEAR OPERATING COMPANY L. M. stinson Vice President Fleet Operations Support

_ ',..

  • I...., '..

A?M< t

, 2007.:.;,

Sworn to and subscribed before me this /3 day of

..*--a*

I

., - ~

..' :, 5.

. # *. \\

,, J 0 e " y i

~

q.

Notary Public

,a t

',A

~

'2... '

I 1--

r:;

=

My commission expires: & Iv 5: 2010 a

!. -7,;:;

~\\ ','.

.. '. 'i

~,

,... ?.,..~,y..;

,,::A LMSICLTIdaj

Enclosures:

1. Response to Request for Additional Information Regarding the Development of Atmospheric Dispersion Factors cc:

Southern Nuclear Operating Company Mr. J. T. Gasser, Executive Vice President Mr. D. R. Madison, Vice President - Hatch Mr. D. H. Jones, Vice President - Engineering RType: CHA02.004 U. S. Nuclear Requlatorv Commission Dr. W. D. Travers, Regional Administrator Mr. R. E. Martin, NRR Project Manager - Hatch Mr. J. A. Hickey, Senior Resident Inspector - Hatch State of Georgia Mr. N. Holcomb, Commissioner - Department of Natural Resources

Edwin I. Hatch Nuclear Plant Request to Implement an Alternative Source Term Response to Request for Additional Information Regarding the Development of Atmospheric Dispersion Factors Edwin I. Hatch Nuclear Plant Request to Implement an Alternative Source Term Response to Request for Additional Information Regarding the Development of Atmospheric Dispersion Factors NRC QUESTION 1 The Nuclear Regulatory Commission (NRC) staff estimated the following distribution of atmospheric stability in the 1996 though 1998 hourly meteorological data files provided as Enclosure 3 to the November 6, 2006, submittal letter:

The frequency of category D appears to be considerably lower, and categories A, F and G higher, than generally observed for other sites with a 50-meter (m) temperature difference (-T) interval. This distribution appears to be more similar to measurements made from a smaller -T interval or possibly a temperature sensor less than 10-m above the ground. Please confirm that the category distributions are estimated from -T measurements between the 60-m and 10-m levels and, if so, describe how the data were converted to represent measurements of C1100 meters. If these data are -T measurements made between the 60-m and 10-m levels, what factors contribute to the relatively low occurrence of category D and moderately frequent occurrences of the A, F and G stability category meteorological conditions at the HNP site?

SNCRESPONSE Stability Category Frequency Occurrence The atmospheric dispersion factors (xIQ) used for the alternative source term (AST) submittal, dated August 29, 2006, were documented in AST enclosure 1 sections 2.1.7 and 2.4. In a letter, dated November 6, 2006, SNC provided further information regarding the atmospheric dispersion factors as requested by the NRC via facsimile on September 29, 2006.

The stability classification category was determined from a delta temperature measurement between 60 and 10 meters. The raw delta temperature measurements that are made at the site are made in degrees Fahrenheit per 164 feet (60-1 0 meters). The reading is then normalized to degrees F1100 feet and converted to a stability class. SNC agrees that the distribution of stability classes is somewhat irregular, in particular with a higher amount of "A" stability class and a lesser than expected amount of " D stability class. However, for the three year period of meteorological data that was used for the AST submittal (1996 through 1998), the percentages of the seven stability classes are consistent. See Table 1 for a breakdown of stability classification both by year and for the three year period.

G 14.1%

A 19.9%

D 16.5%

B 3.7%

E 29.1%

C 3.5%

F 13.2%

Edwin I. Hatch Nuclear Plant Request to Implement an Alternative Source Term Response to Request for Additional Information Reaardinq the Develo~ment of Atmos~heric Dis~ersion Factors The stability classification may have been affected by the growth of trees near the primary meteorological tower during the period of 1996 through 1998. In the spring of 2000, a walkdown identified trees within 100 meters of the primary tower that were taller than the primary tower 10 meter instrumentation. There were no trees or other obstructions as tall as the 60 meter instrumentation on the primary tower.

Section 2.3 of the HNP Unit 2 FSAR, titled "Meteorology (HNP-1 and HNP-2),"

documents that the primary tower was designed in accordance with a proposed revision 1 to Regulatory Guide (RG) 1.23 (it is noted that revision 1 to RG 1.23 was not issued until March, 2007). The referenced proposed revision to RG 1.23 recommended that obstructions taller than the tower instrumentation heights be at a distance away from the tower of at least 10 times the height of the affected instruments. In response to the observed conditions around the primary tower, SNC removed the trees around the primary tower out to approximately 330 feet from the tower. In addition, administrative controls were created to ensure that any potential obstructions within 330 feet of the primary tower are maintained at a height lower than the lowest primary tower instrumentation height.

With respect to the subject three year period of meteorological data, 1996 through 1998, the trees, while not close enough to the primary tower to shade the instrumentation, may have somewhat restricted air movement around the tower, particularly under low wind speed conditions at the 10 meter level. This would have reduced the mixing in the lower levels near the ground and would potentially cause more stable and unstable conditions to occur in the HNP meteorological data during the three years of data that were used in the AST submittal.

The result of this delta temperature data being somewhat atypical is that the main control room and technical support center x/Qs that were calculated for the AST submittal would be conservative. The high percentage of "F and G" stabilities assures that the 0.5% or the 5% x/Q values used for the main control room and technical support center radiological consequences analyses would be more conservative than if the percentages were lower as might be expected.

Edwin I. Hatch Nuclear Plant Request to Implement an Alternative Source Term Response to Request for Additional Information Reaardincr the Development of Atmospheric Dispersion Factors Wind speeds measured at the 10-m level from 1996 through 1998 appear to be lighter than generally reported for other sites, than would be estimated by exponential extrapolation of the 60-m measurements to the 10-m level, and in comparison to the early 1970's data presented in Table 2.3-14 of the HNP Final Safety Analysis Report. NRC staff estimated the 5-percentile 1996 through 1998 10-m measured wind speed to be about 0.4 meterslsecond (m/s) while extrapolation of the 1996 though 1998 60-m winds result in a 5-percentile 10-m wind speed estimate slightly less than 1 mls. Further, the extrapolated 1970's data suggests a 10-m 5-percentile wind speed of approximately 0.7 mls. Both the 1 mls and 0.7 m/s estimates are more similar to the 5-percentile 10-m wind speeds reported at other sites. Do you agree that the 5-percentile 1996 through 1998 10-m wind speed measured at HNP was about 0.4 mls? If so, what factors contributed to these light winds?

SNC RESPONSE SNC agrees that the 5% wind speed for the 10 meter level on the primary meteorological tower for the period of 1996 through 1998 was 0.4 mls. As discussed in response to NRC question 1, instrumentation measurements at the 10 meter level may have been affected by the growth of trees near the primary meteorological tower during the period of 1996 through 1998. SNC addressed the issue in 2000 consistent with applicable regulatory guidance.

Table 2 shows the average wind speed and 5% wind speed for the 10 and 60 meter levels on the primary tower for 1996 through 1998 and also for the last 3 years. It shows that there has only been a slight increase in the wind speed values since the trees were removed. Since HNP, with its location in southeastern Georgia, would be considered a low wind speed site, one would expect the impact of normal year-to-year climatic variation to be similar to the impact of trees around the primary tower.

The result of having slightly lower wind speeds is that the main control room and technical support center x/Q values will be higher than would occur if the average 5% wind speed was 0.45 mls as has occurred during the last three years. The higher xIQ values are conservative for their application in determining the radiological dose consequences for the main control room and technical support center.

Edwin I. Hatch Nuclear Plant Request to Implement an Alternative Source Term Response to Request for Additional Information Reaardina the Development of Atmospheric Dispersion Factors NRC QUESTION 3 Figures 4 and 5 of Enclosure 1 to the November 6, 2006, submittal provide wind roses of the 1996 through 1998 meteorological measurements. Calm winds are listed as having a frequency of occurrence of 0.95% at the 10-m level and 2.05% at the 60-m level. Are calms in this figure defined as winds less than one knot (nautical mile per hour) as suggested by the figure legends? If so, please confirm these estimates. Based upon the 1996 through 1998 hourly data, NRC staff estimated a frequency of approximately 10% for winds less than one knot at the 10-m level and 1 % for winds at the 60-m level.

SNC RESPONSE SNC agrees with the NRC estimate of calms based on review of the submitted 1996 through 1998 hourly meteorological data. SNC also performed a review of the 1996 through 1998 hourly data with calms defined as wind speeds lower than 0.5 mls, approximately equivalent to 1 knot. Based on this criterion, SNC's review yielded calm wind frequencies of approximately 12% for the 10 meter level and 0.7% for the 60 meter level. These frequencies are comparable to the stated NRC estimates.

With respect to the referenced wind rose Figures 4 and 5 from the November 6, 2006 SNC letter, their purpose was to demonstrate that the 1996 through 1998 prevailing wind directions, not calm wind frequencies, remain similar to the historical values. This information was provided in response to NRC question 5, in the same letter, which requested a comparison between the one year meteorological data set used previously and the three year meteorological data set used in the AST submittal. It is noted that wind rose Figures 6 and 7 from the November 6, 2006 SNC letter, based on the one year data set, did not include the calm wind frequencies. The referenced figures 4 and 5 were developed using commercial wind rose software. The commercial software supported the accurate depiction of prevailing wind directions, the focus of the response to the NRC question.

However, the software does not produce high quality calm wind frequencies.

Accurate estimation of the calm wind frequencies should be developed from direct review of the submitted 1996 through 1998 hourly meteorological data. As previously stated, the SNC estimate of calms based on such a review yields comparable results to the stated NRC estimates.

Edwin I. Hatch Nuclear Plant Request to Implement an Alternative Source Term Response to Request for Additional Information Reaardinu the Development of Atmospheric Dis~ersion Factors NRC QUESTION 4 Do the control room atmospheric dispersion factors (xIQ values) listed in the response to NRC Question 1 of Enclosure 1 of the November 6,2006, submittal include consideration of xIQ values applicable to the main steamline break accident (MSLB) and scenarios involving a loss of offsite power and other single failure?

Which xIQ values were used to model unfiltered inleakage into the control room and what is the basis for their use?

SNC RESPONSE The xIQ values listed in the response to NRC question 1 in the November 6, 2006 SNC letter are not design basis accident (DBA) specific. These xIQ values were used for determining the radiological doses for occupants in the main control room and technical support center for each of the HNP DBAs, specifically the loss-of-coolant accident, main steam line break accident, control rod drop accident, and fuel handling accident. The impacts of loss of offsite power and other single failures were considered as part of the overall radiological dose consequences analysis consistent with the guidance of RG 1.1 83, "Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Reactors," dated July, 2000, and the HNP current licensing basis.

As stated in the referenced response to NRC question 1 in the November 6, 2006 SNC letter, of all the release points evaluated for releases from the turbine building, the Unit 2 reactor building vent yields the highest main control room and technical support center xIQ values. Hence, this release point is conservative regardless of whether there is loss of offsite power. Therefore, the reactor building vent xIQ values are used for main control room and technical support center filtered air intake from the outside.

It is important to note that unfiltered inleakage into the main control room is modeled without xIQ values as a direct flow from the turbine building to the main control room, conservatively reflecting the plant configuration with the common main control room located inside the HNP Unit 1 and 2 turbine buildings.

Consequently, doses due to unfiltered inleakage and ingresslegress account for 99.9% of the main control room dose. The outside air intake pathway, modeled with the subject xIQ values, contributes only 0.1 % of the main control room dose.

Edwin I. Hatch Nuclear Plant Request to Implement an Alternative Source Term Response to Request for Additional Information Reaardina the Development of Atmospheric Dispersion Factors NRC QUESTION 5 Please justify use of the 10-m and 60-m meteorological data to calculate the control room xIQ values for postulated releases from the 101.7-m stack rather than meteorological data measured at the 10-m and 100-m levels. Regulatory Guide (RG) 1.1 94, "Atmospheric Relative Concentrations for Control Room Radiological Habitability Assessments at Nuclear Power Plants," and NRC Regulatory Issue Summary 2006-04, "Experience with Implementation of Alternative Source Terms,"

recommend that if wind measurements are available at more than two elevations, the data at the height closest to the release height should be used when running the ARCON96 computer code.

SNC RESPONSE The 60 meter level wind speed and direction values were used rather than the 100 meter level for the main control room and technical support center xIQ values because the data recovery rates at the 60 meter level were much better than at the 100 meter level. For the year 1996 the data recovery rate at 100 meters was below the 90% allowable rate per RG 1.23 guidance. Therefore, it was decided to use the 60 meter level for all three years to be consistent.

Using the 60 meter level rather than the 100 meter level to calculate the xIQ values will result in conservative xIQ values since the average wind speed values are lower at the 60m level.

Edwin I. Hatch Nuclear Plant Request to Implement an Alternative Source Term Response to Request for Additional Information Reaardina the Development of Atmospheric Dispersion Factors NRC staff notes that there are no 0-0.5 hour5.787037e-5 days <br />0.00139 hours <br />8.267196e-6 weeks <br />1.9025e-6 months <br /> fumigation x/Q values explicitly given for postulated releases from the Hatch stack to the exclusion area boundary (EAB) and low population zone (LPZ). RG 1.1 83, "Alternative Radiological Source Terms for Evaluating Design Basis Accidents at Nuclear Power Reactors," states that fumigation should be considered where applicable for the EAB and LPZ. For the EAB, the assumed fumigation period should be timed to be included in the worst 2-hour exposure period. Do the elevated release 0-2 hour EAB and LPZ x/Q values include fumigation? If not, why is fumigation considered inapplicable?

SNCRESPONSE Section 5.3 of RG 1.I83 states the followiug: "Atmospheric dispersion values (xIQ) for the EAB, the LPZ, and the control room that were approved by the staff during initial facility licensing or in subsequent licensing proceedings may be used in performing the radiological analyses identified by this guide." In addition, previously referenced Regulatory Issue Summary 2006-04 section 4 states: "Licensees may continue to use atmospheric relative concentration (xIQ) values and methodologies from their existing licensing-basis analyses when appropriate."

As stated in the previously referenced sections 2.1.7 and 2.4 of enclosure 1 of the AST submittal, for the AST DBA offsite dose analyses SNC continued to apply the current licensing basis offsite x/Q values. The specific EAB and LPZ x/Q values used for AST are listed in table 5 of enclosure 1 of the AST submittal. The source information for table 5 came from Unit 2 FSAR table 2.3-1 1 which is applicable to both HNP Units 1 and 2.

Edwin I. Hatch Nuclear Plant Request to Implement an Alternative Source Term Response to Request for Additional Information Reuardinu the Development of Atmospheric Dispersion Factors Table 1 PERCENT OF EACH STABILITY CLASS (60-1 0 Meter)

Stability 1996 1997 1998 3 Year Class Average Recovery 1

Edwin I. Hatch Nuclear Plant Request to Implement an Alternative Source Term Response to Request for Additional Information Reaardina the Development of Atmospheric Dispersion Factors Table 2 WIND SPEED COMPARISON