Letter Sequence Other |
|---|
|
|
MONTHYEARRBG-46583, License Amendment Request, Changes to the Analytical Methods Referenced in Technical Specification 5.6.5, Core Operating Limits Report (Colr)2006-10-16016 October 2006 License Amendment Request, Changes to the Analytical Methods Referenced in Technical Specification 5.6.5, Core Operating Limits Report (Colr) Project stage: Request ML0717700952007-05-10010 May 2007 Draft, Attachment to 5/10/07 E-Mail from Rwbyrd, Entergy, to Bvaidya, Nrr/Dorl/Lpliv, Enclosing Draft Response to Request for Additional Info Re LAR to Update LOCA Methodology Project stage: Draft Request ML0717700922007-05-10010 May 2007 5/10/07 E-Mail from Rwbyrd, Entergy, to Bvaidya, Nrr/Dorl/Lpliv, Enclosing Draft Response to Request for Additional Info Re LAR to Update LOCA Methodology Project stage: Draft Request ML0717701072007-06-13013 June 2007 6/13/07 E-Mail from T. Huang, Nrc/Nrr/Dss, to B. Vaidya, Nrr/Dorl/Lpliv, Re Process to Finalize Draft Response to Request for Additional Info Re LAR to Update LOCA Methodology Project stage: Draft Approval ML0717701132007-06-14014 June 2007 6/14/07 E-Mail from Bvaidya, Nrr/Dorl/Lpliv, to Rwbyrd, Entergy, Enclosing 6/13/07 E-mail from NRC Review of Draft Response to Request for Additional Info Re LAR to Update LOCA Methodology Project stage: Draft Approval ML0717701272007-06-25025 June 2007 Attachment to 6/25/07 E-Mail from Rwbyrd, Entergy, to Bvaidya, Nrr/Dorl/Lpliv, Enclosing Revised Draft Response to Request for Additional Info Re LAR to Update LOCA Methodology Project stage: Draft Request ML0717701212007-06-25025 June 2007 6/25/07 E-Mail from Rwbyrd, Entergy, to Bvaidya, Nrr/Dorl/Lpliv, Enclosing Revised Draft Response to Request for Additional Info Re LAR to Update LOCA Methodology Project stage: Draft Request RBG-46182, Supplement to Amendment Request, Changes to the Analytical Methods Referenced in Technical Specification 5.6.5, Core Operating Limits Report (COLR)2007-07-30030 July 2007 Supplement to Amendment Request, Changes to the Analytical Methods Referenced in Technical Specification 5.6.5, Core Operating Limits Report (COLR) Project stage: Supplement ML0722200262007-08-30030 August 2007 Tech Spec Page for Amendment 153 Changes to the Analytical Methods Referenced in Technical Specification 5.6.5, Core Operating Limits Report (Colr) Project stage: Other ML0722200222007-08-30030 August 2007 Issuance of Amendment 153 Changes to the Analytical Methods Referenced in Technical Specification 5.6.5, Core Operating Limits Report (Colr) Project stage: Approval RBG-46847, License Amendment Request, 10 CFR 50.46(a)(3)(ii) Report2008-09-22022 September 2008 License Amendment Request, 10 CFR 50.46(a)(3)(ii) Report Project stage: Request 2007-06-14
[Table View] |
Text
Reporting Requirements 5.6 RIVER BEND 5.0-18b Amendment No.
5.6 Reporting Requirements 5.6.5 CORE OPERATING LIMITS REPORT (COLR) (continued)
- 12)
XN-NF-825(P)(A), Supplement 2, BWR/6 Generic Rod Withdrawal Error Analysis, MCPRp for Plant Operations within the Extended Operation Domain, Exxon Nuclear Company, Richland, WA.
- 13)
ANF-1358(P)(A), The Loss of Feedwater Heating Transient in Boiling Water Reactors, Advanced Nuclear Fuels Corporation, Richland, WA.
- 14)
EMF-1997(P)(A), ANFB-10 Critical Power Correlation, Siemens Power Corporation, Richland, WA.
- 15)
EMF-1997(P) Supplement 1 (P)(A), ANFB-10 Critical Power Correlation High Local Peaking Results, Siemens Power Corporation, Richland, WA.
- 16)
EMF-2209(P)(A), SPCB Critical Power Correlation, Siemens Power Corporation, Richland, WA.
- 17)
EMF-2245(P(A), Application of Siemens Power Corporations Critical Power Correlations to Co-Resident Fuel, Siemens Power Corporation, Richland, WA.
- 18)
EMF-2361(P)(A), EXEM BWR-2000 ECCS Evaluation Model, Framatome ANP Richland, Inc.
- 19)
Deleted
- 20)
Deleted
- 21)
Deleted
- 22)
EMF-CC-074(P)(A), Volume 4, BWR Stability Analysis Assessment of STAIF with Input from MICROBURN-B2, Siemens Power Corporation, Richland, WA.
- 23)
EMF-2292(P)(A), ATRIUM-10 Appendix K Spray Heat Transfer Coefficients, Siemens Power Corporation, Richland, WA.
153